HomeMy WebLinkAboutSUB201800097 Review Comments Preliminary Plat 2018-09-21pF A vt�cttylQ COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 Preliminary Plat review Project: Rio Vista — Preliminary Plat Plan preparer: Justin Shimp, PE, Shimp Engineering — 201 E. Main St., Suite M Charlottesville, VA 22902 fiustin(a,shimp-engineering.com ] Owner or rep.: Rio Vista LLC, PO Box 5787, Charlottesville, VA 22905 Plan received date: 22 May 2018 (Rev. 1) 20 Sep 2018 Date of comments: 3 July 2018 (Rev. per SRC) 10 July 2018 (Rev. 1) 21 Sep 2018 Reviewer: John Anderson Project Coordinator: Christopher Perez SUB2018-00097 1. An approved WPONSMP Plan is required prior to final plat approval. Consider stormwater quality and quantity (engineering design) alternatives at level of detail required to show conceptual locations of required drainage, and SWM treatment or detention required for an approved VSMP Plan; provide conceptual locations with preliminary plat (14-302.A.13). 2. Delete C1 Subdivision Note 6, which appears to assume a pre -determined VSMP/WPO review outcome. For example, in plan review meeting with Applicant, need for curb and gutter for eventual conceptual design (essentially, two driveway entrances off Rio Road instead of a private street or public road) was discussed. Streets in an urban areas require an urban section, which requires curb and gutter. Applicant, in letter request for exception (Section 14-404(A)), dated 8/24/18, states that `Compliance with subsection G [ 14-410(G)] is anticipated with the review of a final plat application,' which means the Applicant rightly anticipates drainage elements are required. 14-410(G): G. Drainage. Adequate drainage control shall be provided for streets by installing culverts under streets; side, lead, or outlet ditches; catch basins; curb inlets; or any other devices, including piping, ned as determito be necessary by the county engineer. All of these improvements shall meet the standards of the county or, in the event no county standards exist, Virginia Department of Transportation standards. Once system elements, including piping, concentrate runoff from proposed impervious area, Chapter 17 stormwater quantity requirements listed at 9VAC25-870-66 require both channel and flood protection requirements that conflict with apparent proposal to discharge concentrated runoff directly into the floodplain (or floodway) without attenuating stormwater peak discharge or velocity. In any event, plan review will consider stormwater-related design issues, once a VSMP/WPO plan is submitted. 3. Related to 2., show conceptual location/s of SWM pipes that avoid preserved steep slopes. 4. Related, propose location/s for SWM facilities that may be required that avoid streamward 50' of buffers. 5. Related, if a SWM facility is proposed to lie within the 100 -year floodplain, design may not include fill, or decrease the cross-sectional area of the floodplain or floodway of Meadow Creek, at any point. 6. A new sanitary sewer is proposed within the 100 -year floodplain. Submit a Floodplain Development Permit Application to show (that): a. Construction of the proposed sanitary sewer line does not decrease the cross-sectional area of the floodplain at any point; does not increase the base flow elevation of the floodplain at any point. Engineering Review Comments Page 2 of 3 b. Development activity will not increase the base flow elevation (BFE) or extent of the floodplain at any point (no increase in horizontal dimensions of floodplain). c. Applicant is directed to Code 18-30.3, Flood Hazard Overlay District, especially 30.3.11 - 30.3.15 (Note: 30.3.15.A.6 is of particular relevance; table at 30.3.11 provides by right water -related and public utility use within a FEMA FIM Map Zone AE regulatory floodway). d. Regulatory floodway. Ref. on-line VFRIS (image below). e. Regulatory floodway on preliminary plat, sheets C2 and C5 (14-302.B.9). f. Also, with the FDP Application, submit PE -seal `No Rise' Certificate, prepared by a professional engineer licensed to practice in the state of Virginia. 7. Related to 4, 5, 6.d. -e., provide with preliminga plat required information listed at 14-302.B.9, including elevation of lowest floors of proposed structures, and USGS vertical datum shown and/or correlated to plat topography. Show proposed elevations. Preliminary plat lacks proposed contours, without which, it is not possible to evaluate potential impact to preserved slopes, stream buffer, floodplain /floodway. 8. Note: If VDOT and Albemarle County Agent /Commission approve Request for Exception (Section 14- 404.A), a Road Plan is not required since entrances to subdivision will be, in effect, shared driveways fronting Rio Road, separated by approximately 50'. 9. With preliminary plat, provide easements (with dimensions) required at 14-302.A.4, -5, -6. 10. Note: Preliminary plat (conceptual design) requires approval of Request for Exception (Section 14-404(A)). Request submitted as letter d. 8/24/18. With final plat & WPONSMP 11. Show and label floodway and floodway fringe (see VFRIS image, below). 12. Note: Stream buffer crossing Rio Road is not considered stream buffer for ordinance purposes. Rio Road is manmade hardscape with no runoff limiting capacity. Applicant may view Meadow Creek stream buffer crossing Rio Road from the west as irrelevant, with no influence or effect on design. County GIS — preserved steep slopes (green); stream buffer (salmon); floodplain (blue). Note: Area that is not in steep slopes, stream buffer, or floodplain is white /unshaded. Engineering Review Comments Page 3 of 3 VFRIS —Virginia Flood Risk Information System — blue is floodway fringe; purple is floodway Link: http://cmap2.vims.eduNaFloodRisk/vfris2.htm1 Please feel free to call if any questions: 434.296-5832 —x3069 Thank you SUB201800097-Rio—Vista—rev092118rev l_prelim-plat.doc COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 Preliminary Plat review Project: Rio Vista — Preliminary Plat Plan preparer: Justin Shimp, PE, Shimp Engineering — 201 E. Main St., Suite M Charlottesville, VA 22902 fiustin(&shimp-engineering.com ] Owner or rep.: Rio Vista LLC, PO Box 5787, Charlottesville, VA 22905 Plan received date: 22 May 2018 Date of comments: 3 July 2018 (Rev. per SRC) 10 July 2018 Reviewer: John Anderson Project Coordinator: Christopher Perez SUB2018-00097 1. A Road Plan (RP) is required prior to final plat approval. 2. A WPONSMP Plan is required prior to final plat approval. 3. Preliminary plat requires written request to disturb steep slopes; they are certain to be disturbed with this proposed subdivision (14-304). (Engineering will recommend denial.) (Rev.) If steep slopes are proposed to be disturbed, written request to County Engineer is required. County Engineer approval is required. 4. Provide stormwater management information, as required (14-305). 5. Provide response to Planning comments dated July 2, 2018, especially items 2, 3, 6, 11, 12, 13, 18, 19. These comments address Engineering concerns and requirements, as well. With RP 6. If a private street is proposed, design to VDOT standards, per Albemarle County Design Standards Manual guidance for private streets (14-412.A.2.(b) for ref. to ACDSM). (Rev.) Project may be eligible for standard for street serving two (2) lots where a driveway departs from the street and two lots remain to be served, and a turnaround is provided, depending upon design proposal (14-412.A.2.). Engineering defers to Planning interpretation of subdivision ordinance. 7. If a private street is proposed, provide private access easement. Design to VDOT standards. (Rev.) Design to VDOT standards for three to five lots if waive two lot -driveway option at 46, above. 8. If a public road is proposed, provide right-of-way. Design to VDOT standards. 9. Provide roadway profile; provide drainage, drainage computations, etc. (ref. review checklists). With final plat & WPONSMP 10. Show and label floodway and floodway fringe (see VFRIS image, below). 11. Show all stream buffers, including to the west (image, below). Refer to images below for critical resource information, and boundaries. (Rev.) Stream buffer crossing Rio Road is not considered stream buffer for ordinance purposes. Rio Road is manmade hardscape with no runoff limiting capacity. Applicant may view Meadow Creek stream buffer crossing Rio Road from the west as irrelevant, without bearing on design. 12. Avoid stream buffers. Stream buffer impact is impermissible on this lot. See item #13, Note, below. Engineering Review Comments Page 2 of 5 13. Remove proposed improvements from the super -adjacent airspace above preserved steep slopes. 18-30.7.4- b. makes no allowance for subdivision as proposed, or improvements of the type shown. 14. Note: Area of existing pawel that is not a struottir-e, presen,ed slope-, floodplain (floo",ay /floodway n-inge)or- stFe m buffer measures 12,230 f'' 0=), 0.28 Acr-e. in this spaoe, preli,,,;.,aFy plat proposes tr-avelway inoonsisteat with public or- pr-ivate road standards; additional i . ; constpaotion above presen,ed slopes (Gotinty rejects this design); impr-ovements in stream buffer- that extends aer-oss Rio Road; no S3AIN r and adve -se impacts to oonjoinedimpair-ed stfe ms This preliminary plat is problematic. Please examine Chapter 14 and 17 with care: a. Sec. 17-602: Types of improvements and activities exempt from duties to retain, establish, or manage a stream buffer. b. Sec. 17-603: Types of structures, improvements and activities authorized in a stream buffer. Note particularly A.: Pre-existing building or structures. Any building or structure which existed on February 11, 1998 may continue in its location on that date. However, nothing in this section authorizes the continuance, repair, replacement, expansion or enlargement of any such building or structure except as provided in sections 18-6 and 18-30.3. c. 17-604: Types of structures, improvements and activities which may be allowed in a stream buffer by program authority. Within the landward SO horizontal feet offers guidance relative to improvements necessary for reasonable use of the lot, but existing stone access /parking does this. There is no need to construct a new travelway to enable reasonable use of the existing lot. d. 17-604.C. pertains to stream crossings and is not applicable. Counter — preserved steep slopes (green); stream buffer (salmon); floodplain (blue). Note: Area that is not in steep slopes, stream buffer, or floodplain is white /unshaded. Engineering Review Comments Page 3 of 5 Land Records, BK4985-PG494 201700013483.004 SCHEDULE"A" All that certain lot or parcel of land, with improvements thereon and appurtenances there situated in the County of Albemarle, Virginia, fronting an Rio Road, containing 2.142 act more or less, as shown on a plat by B. Aubrey Huffman & Associates, Ltd., dated September' 1483, and recorded in the Clerk's Office of the Circuit Court of the County of Albanian Virginia, in Deed Book 778, page 43, BEING the same property conveyed to the Grant herein, by deed from Thomas A. Lane, Jr., dated October 18, 2003, retarded January 15, 20, in the said Clerk's Office, in Deed Book 2674, page 290. By Trustee's Deed dated August 2015, recorded September 4, 2015, in Deed Book 4670, page 125, Trustee Services of Virgir. LLC, Substitute Trustee, conveyed the subject property to Wells Fargo Bank, Natio: Association as Trustee for Option One Mortgage Loan Trust 2005-4, Asset Backed Certiftcat Series 2005-4. By Order dated June 7, 2016, recorded June 16, 2016, in Deed Book 4771, ps 716, said Trustee's Deed was stricken from the land records, and title to the subject property v restored in Thomas A. Lane, Jr. and Carleen I. lane. IWALE CO ' RELO�mALBENAfIt£CO CIRCUR COURT LLFRR'S OFFICE Nev 20, 2017 AT 1141 -- JON R, ZUG, CLERK by EMJ U10.000RANMR TRX WAS PA60 AS REQUIRED 0y SEC W.102OF THE VA. CODE STATE, $205.00 LOCAL: $20500 Virginia Flood Risk Information System (YFR{5i ' t © - �ti si. ji aid ... � _ ado•; aep Engineering Review Comments Page 5 of 5 Please feel free to call if any questions: 434.296-5832 —x3069 Thank you SUB201800097-Rio_V ista_rev071018_prelim-plat. doc COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 Site Plan review Project: Rio Vista — Preliminary Plat Plan preparer: Justin Shimp, PE, Shimp Engineering — 201 E. Main St., Suite M Charlottesville, VA 22902 fiustin(a,shimp-engineering.com ] Owner or rep.: Rio Vista LLC, PO Box 5787, Charlottesville, VA 22905 Plan received date: 22 May 2018 Date of comments: 3 July 2018 Reviewer: John Anderson Project Coordinator: Christopher Perez SUB2018-00097 1. A Road Plan (RP) is required prior to final plat approval. 2. A WPO/VSMP Plan is required prior to final plat approval. 3. Preliminary plat requires written request to disturb steep slopes; they are certain to be disturbed with this proposed subdivision (14-304). (Engineering will recommend denial.) 4. Provide stormwater management information, as required (14-305). 5. Provide response to Planning comments dated July 2, 2018, especially items 2, 3, 6, 11, 12, 13, 18, 19. These comments address Engineering concerns and requirements, as well. With RP 6. If a private street is proposed, design to VDOT standards, per Albemarle County Design Standards Manual guidance for private streets (14-412.A.2.(b) for ref. to ACDSM). 7. If a private street is proposed, provide private access easement. Design to VDOT standards. 8. If a public road is proposed, provide right-of-way. Design to VDOT standards. 9. Provide roadway profile; provide drainage, drainage computations, etc. (ref. review checklists). With final plat & WPO/VSMP 10. Show and label floodway and floodway fringe (see VFRIS image, below). 11. Show all stream buffers, including to the west (image, below). Refer to images below for critical resource information, and boundaries. 12. Avoid stream buffers. Stream buffer impact is impermissible on this lot. See item #13, Note, below. 13. Remove proposed improvements from the super -adjacent airspace above preserved steep slopes. 18-30.7.4- b. makes no allowance for subdivision as proposed, or improvements of the type shown. 14. Note: Area of existing parcel that is not a structure, preserved slope, floodplain (floodway /floodway fringe), or stream buffer measures 12,230 ft2 (f), —0.28 Acre. In this space, preliminary plat proposes travelway inconsistent with public or private road standards; additional impervious area; construction above preserved slopes (County rejects this design); improvements in stream buffer that extends across Rio Road; no SWM, and adverse impacts to conjoined impaired streams. This preliminary plat is problematic. Please examine Chapter 14 and 17 with care: Engineering Review Comments Page 2 of 5 a. Sec. 17-602: Types of improvements and activities exempt from duties to retain, establish, or manage a stream buffer. b. Sec. 17-603: Types of structures, improvements and activities authorized in a stream buffer. Note particularly A.: Pre-existing building or structures. Any building or structure which existed on February 11, 1998 may continue in its location on that date. However, nothing in this section authorizes the continuance, repair, replacement, expansion or enlargement of any such building or structure except as provided in sections 18-6 and 18-30.3. c. 17-604: Types of structures, improvements and activities which may be allowed in a stream buffer by program authority. Within the landward 50 horizontal feet offers guidance relative to improvements necessary for reasonable use of the lot, but existing stone access /parking does this. There is no need to construct a new travelway to enable reasonable use of the existing lot. d. 17-604.C. pertains to stream crossings and is not applicable. Counter — preserved steep slopes (green); stream buffer (salmon); floodplain (blue). Note: Area that is not in steep slopes, stream buffer, or floodplain is white /unshaded. Engineering Review Comments Page 3 of 5 Land Records, BK4985-PG494 201700013483.004 SCHEDULE"A" All that certain lot or parcel of land, with improvements thereon and appurtenances there situated in the County of Albemarle, Virginia, fronting an Rio Road, containing 2.142 act more or less, as shown on a plat by B. Aubrey Huffman & Associates, Ltd., dated September' 1483, and recorded in the Clerk's Office of the Circuit Court of the County of Albanian Virginia, in Deed Book 778, page 43, BEING the same property conveyed to the Grant herein, by deed from Thomas A. Lane, Jr., dated October 18, 2003, retarded January 15, 20, in the said Clerk's Office, in Deed Book 2674, page 290. By Trustee's Deed dated August 2015, recorded September 4, 2015, in Deed Book 4670, page 125, Trustee Services of Virgir. LLC, Substitute Trustee, conveyed the subject property to Wells Fargo Bank, Natio: Association as Trustee for Option One Mortgage Loan Trust 2005-4, Asset Backed Certiftcat Series 2005-4. By Order dated June 7, 2016, recorded June 16, 2016, in Deed Book 4771, ps 716, said Trustee's Deed was stricken from the land records, and title to the subject property v restored in Thomas A. Lane, Jr. and Carleen I. lane. IWALE CO ' RELO�mALBENAfIt£CO CIRCUR COURT LLFRR'S OFFICE Nev 20, 2017 AT 1141 -- JON R, ZUG, CLERK by EMJ U10.000RANMR TRX WAS PA60 AS REQUIRED 0y SEC W.102OF THE VA. CODE STATE, $205.00 LOCAL: $20500 Engineering Review Comments Page 4of5 VFRIS —Virginia Flood Risk Information System — blue is floodway fringc; purplc is floodway Link: http:Hcmap2.vims.eduNaFloodRisk/vfris2.htm1 Engineering Review Comments Page 5 of 5 Please feel free to call if any questions: 434.296-5832 —x3069 Thank you SUB201800097-Rio_V ista_070318—Prelim-plat.doc PLAN REVIEW COMMENTS - E911 APPLICATION#: SUB201800097 TMP: 06100-00-00-19100 DATE: 6/14/18 FROM: Elise Kiewra ekiewra@albemarle.org Geographic Data Services (GDS) www.albemarle.org/gds (434) 296-5832 ext. 3030 This site will require a one (1) new private road name. Per Sec. 7-200-B of the County's Road Naming and Property Numbering Ordinance (Page 2 of PDF). "It is intended by this article that all roads within the county which serve or are designed to serve three (3) or more dwelling units or business structures shall be named." Please review the procedures in the Road Naming and Property Numbering Manual to decide upon a road name for the road accessing Old Lynchburg Road. We recommend providing three (3) candidate names for each road to our office for review, in case your first choices are not acceptable. A PDF version of the Ordinance and Manual can be found here: https://www.albemarle.org/upload/images/Forms_Center/Departments/Geographic_Data_Servi ce s/Forms/Road_Naming_and_Property_Numbering_Ordinance_and_Manual.pdf Please consult the County's Road Name Index to check your road names prior to submittal. The Index can be found here: http://www.albemarle.org/albemarle/upload/images/webapps/roads/ Parcel and mapping information can be found here: http://gisweb.albemarle.org/ If you should have any questions, please do not hesitate to contact our office. County of Albemarle Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper, Virgin a 22701 Stephen C. Brich, P.E. Commissioner October 18, 2018 Christopher Perez County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SDP -2019-00097- Rio Vista — Preliminary Subdivision Plat Dear Mr. Perez: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Shimp Engineering, P.C., dated May 21, 2018, revised August 22, 2018 and find it to be generally acceptable. Land Use 1. Please label on plat; prescriptive easement to be dedicated to County for future public use. Please provide two copies of the revised plan along with a comment response letter. If further information is desired, please contact Willis C. Bedsaul at 434-422-9866. A VDOT Land Use Permit will be required prior to any work within the right of way. The owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, Adam J. M re, P.E. Area Land Use Engineer Charlottesville Residency WE KEEP VIRGINIA MOVING Christopher Perez From: Richard Nelson <rnelson@serviceauthority.org> Sent: Tuesday, October 16, 2018 8:14 AM To: Christopher Perez Subject: SUB201800097 Rio Vista - Preliminary Chris, Below are comments for SUB201800097 Rio Vista — Preliminary: Correctly show RWSA water main location. Callout proposed sewer as ACSA not RWSA. Thanks, Richard Nelson Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (434) 977-4511 Christopher Perez From: Victoria Fort <vfort@rivanna.org> Sent: Monday, October 15, 2018 5:52 PM To: Christopher Perez Cc: Richard Nelson Subject: SUB201800097 Rio Vista - Preliminary Attachments: SUB201800097 - Rio Vista - Preliminary Chris & Richard, RWSA has reviewed the resubmittal of the preliminary plat for Rio Vista, dated 8/22/2018. RWSA's previous comments (see attached email, dated 6/28/2018) were not fully addressed in the resubmittal. I have reiterated these and included additional comments below: Sheet C4 of 5 (Existing Conditions): 1. Correctly show the location of the existing RWSA 18" water main (located on the west side of Rio Road, not on the east side, as shown). 2. Show and label the existing RWSA 42" sanitary sewer main and easement across the entire subject property. Sheet C5 of 5 (Preliminary Lot Layout): 1. Correctly show the location of the RWSA 18" water main. 2. Show and label the existing RWSA 42" sanitary sewer main, and the sanitary easement (with Deed Book and Page Number) across the entire subject property. 3. The proposed new sewer line shown as "new RWSA sewer" will belong to ACSA, please revise the label accordingly. 4. The proposed sewer easement should be labeled "new 20' ACSA sewer easement" 5. Proposed water and sewer connections will require RWSA review and approval and all work will be subject to inspection by RWSA staff. Please note that the RWSA manhole where a connection is proposed has an HDPE liner that will need to be repaired to RWSA's satisfaction using approved methods, materials, and an approved contractor. Please let me know if you have any questions. Thanks, Victoria Victoria Fort, P.E. Senior Civil Engineer Rivanna Water and Sewer Authority 695 Moores Creek Lane Charlottesville, VA 22902 (0): (434) 977-2970 ext. 205 (F): (434) 295-1146 �pF AL COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434)296-5832 July 2, 2018 Justin Shimp 912 E. High Street Charlottesville VA 22902 SUB2018-97 Rio Vista - Preliminary Subdivision Plat Dear Mr. Shimp: The Site Review Committee has reviewed the development proposal referenced above. Initial comments for the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Planning Services Albemarle County Engineering Services Albemarle County Service Authority Rivanna Water and Sewer Authority Virginia Department of Transportation Albemarle County Department of Fire Rescue Albemarle County Building Inspections Albemarle County Information Services (E911) Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that will be required to be resolved prior to Final Plat approval. Please request deferral of this proposal. At a minimum resubmit the plat to address review comments 1- 6. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, Christopher P. Perez Senior Planner � OF ALgx,. �n `IRGINZP County of Albemarle Department of Community Development 401 McIntire Road, Charlottesville, VA, 22902 434-296-5832 The County of Albemarle Planning Division will grant or recommend approval of the Subdivision Plat referenced above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. [Comment] The public notification fee of $215 was not paid prior to the SRC meeting. Prior to preliminary subdivision plat conditional approval the fee shall be paid. 2. [1.7(C)(3), 30.7.4, 4.2.11 Portions of the cantilevered single family detached residential structures are within the superjacent airspacer'l of the preserved slopes zoning overlay district and are deemed to be within the same district as the parcel. New residential structure are not a permitted use in the preserved slopes overlay zoning district. Additionally, the residential units are not completely within a building site, as a building site shall not contain land that is in preserved slopes. No structure or improvement shall be located on any lot of parcel in any area other than a building site. Please remove all new structures from the superjacent airspace of the preserved slopes. Prior to preliminary subdivision plat conditional approval a resubmittal that adequately addressed this comment shall be required. 3. [3.1, 14-2331 Definitions. The proposed access road serving the lots is not appropriately labeled, nor approvable as submitted. How this access is proposed/labeled will determine how the application moves forward. It currently does not meet the definition of an alley', it does not meet the definition of a shared driveway'; rather, it appears to only meet the definition of a private street3. Prior to preliminary subdivision plat conditional approval revise the plat to label it as a private street, and submit the private street request along with all required justifications. Make all required findings under Section 14-233(A)(1), Section 14-233(A)(3), and Section 14-234(C). The request does not need to be acted on prior to conditional approval of the preliminary plat; however, prior to final subdivision plat approval the private street shall be approved by the Planning Commission. 4. [14-404] Single Point of Access Required. Each lot shall have reasonable access to the building site from only one street established at the time of the subdivision. The existing gravel driveway and entrance serving the existing duplex shall be closed and abandoned. Prior to preliminary subdivision plat conditional approval a resubmittal that adequately addressed this comment shall be required. 5. [4.19] Non Infill Setbacks. Revise the special exception request to accurately reference the proposed access road to serve the lots. As mentioned above the access road does not meet the definition of a shared driveway. This special t'l Superjacent and Subjacent Airspace. The superjacent and subjacent airspace of any unincorporated territory within the County shall be deemed to be within the same district as the parcel to which it pertains unless the superjacent or subjacent airspace is zoned otherwise by a zoning map amendment. 'Alley. The term "alley" means a form of vehicular travelway providing access to the rear and/or side lot line of abutting properties which front along streets. An alley is privately owned and maintained, is intended to be used primarily by the owners and occupants of the abutting properties and persons and vehicles providing services to those properties, including emergency services vehicles, and is not intended for through traffic. An alley is not a "private street." 2 Shared driveway. The term "shared driveway" means a vehicular access to only two lots which have frontage on a street and which are authorized pursuant to section 14-236. a Street, private. The term "private street" means any street or other way or means of vehicular access approved as a "private street' pursuant to sections 14-232 through 14-235 or as a "private road" under any prior ordinance regulating the subdivision of land, that is not designed, constructed, bonded or approved to be maintained by the Virginia Department of Transportation as part of the secondary system of state highways, regardless of ownership. Any street identified on a recorded plat as a restricted road, access road or other designation which was not approved by the county as a private street or a private road as described herein is not a private street. 1 Memorandum To: Justin Shimp From: Christopher Perez, Senior Planner Division: Planning Date: July 2, 2018 Subject: SUB2018-97 Rio Vista - Preliminary Subdivision Plat The County of Albemarle Planning Division will grant or recommend approval of the Subdivision Plat referenced above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. [Comment] The public notification fee of $215 was not paid prior to the SRC meeting. Prior to preliminary subdivision plat conditional approval the fee shall be paid. 2. [1.7(C)(3), 30.7.4, 4.2.11 Portions of the cantilevered single family detached residential structures are within the superjacent airspacer'l of the preserved slopes zoning overlay district and are deemed to be within the same district as the parcel. New residential structure are not a permitted use in the preserved slopes overlay zoning district. Additionally, the residential units are not completely within a building site, as a building site shall not contain land that is in preserved slopes. No structure or improvement shall be located on any lot of parcel in any area other than a building site. Please remove all new structures from the superjacent airspace of the preserved slopes. Prior to preliminary subdivision plat conditional approval a resubmittal that adequately addressed this comment shall be required. 3. [3.1, 14-2331 Definitions. The proposed access road serving the lots is not appropriately labeled, nor approvable as submitted. How this access is proposed/labeled will determine how the application moves forward. It currently does not meet the definition of an alley', it does not meet the definition of a shared driveway'; rather, it appears to only meet the definition of a private street3. Prior to preliminary subdivision plat conditional approval revise the plat to label it as a private street, and submit the private street request along with all required justifications. Make all required findings under Section 14-233(A)(1), Section 14-233(A)(3), and Section 14-234(C). The request does not need to be acted on prior to conditional approval of the preliminary plat; however, prior to final subdivision plat approval the private street shall be approved by the Planning Commission. 4. [14-404] Single Point of Access Required. Each lot shall have reasonable access to the building site from only one street established at the time of the subdivision. The existing gravel driveway and entrance serving the existing duplex shall be closed and abandoned. Prior to preliminary subdivision plat conditional approval a resubmittal that adequately addressed this comment shall be required. 5. [4.19] Non Infill Setbacks. Revise the special exception request to accurately reference the proposed access road to serve the lots. As mentioned above the access road does not meet the definition of a shared driveway. This special t'l Superjacent and Subjacent Airspace. The superjacent and subjacent airspace of any unincorporated territory within the County shall be deemed to be within the same district as the parcel to which it pertains unless the superjacent or subjacent airspace is zoned otherwise by a zoning map amendment. 'Alley. The term "alley" means a form of vehicular travelway providing access to the rear and/or side lot line of abutting properties which front along streets. An alley is privately owned and maintained, is intended to be used primarily by the owners and occupants of the abutting properties and persons and vehicles providing services to those properties, including emergency services vehicles, and is not intended for through traffic. An alley is not a "private street." 2 Shared driveway. The term "shared driveway" means a vehicular access to only two lots which have frontage on a street and which are authorized pursuant to section 14-236. a Street, private. The term "private street" means any street or other way or means of vehicular access approved as a "private street' pursuant to sections 14-232 through 14-235 or as a "private road" under any prior ordinance regulating the subdivision of land, that is not designed, constructed, bonded or approved to be maintained by the Virginia Department of Transportation as part of the secondary system of state highways, regardless of ownership. Any street identified on a recorded plat as a restricted road, access road or other designation which was not approved by the county as a private street or a private road as described herein is not a private street. 1 exception to setbacks may not be needed if the access is proposed as a private street. Currently staff is not supportive of the special exception request, as it pushes the building footprint closer to the preserved slopes and to the stream. Prior to final subdivision plat approval the SE to setbacks (if still needed) shall be approved by the Board of Supervisors. 6. [14-302(A)12] Topography. Label all topographic contour intervals. 7. [14-414] Public Sewer. Prior to final subdivision plat approval an offsite ACSA sewer easement is required to connect to public sewer on TMP 61-190. 8. [15.3] Max Structure Height. Provide the maximum structure height of 35 feet. 9. [14-303(D), 18-15.31 Acreage. Provide the following note under the density: "Standard Level Conventional Development —Minimum Lot Size 10, 890 SF. " 10. [14-302(A)8] Proposed Lots. Provide the dimensions for each lot. 11. [4.12.6] Parking. On the road plan depict, label, and dimension the two required parking spaces per lot. If garages are proposed, please label, depict, and dimension the parking space(s) within. 12. [14-410] Curb, curb and gutter, sidewalks and planting strips. In the development areas, streets shall be constructed with curb or curb and gutter, sidewalks and planting strips. 13. [14-410(C)] Temporary Turnarounds. Streets proposed to serve more than four (4) dwelling units shall be provided with a temporary turnaround meeting American Association of State Highway and Transportation Officials guidelines. The temporary turnaround shall be extended to the abutting property line unless a waiver is granted as provided in section 14-409(D). The temporary turnaround shall exist until the street extensions are accepted into the secondary system of state highways. 14. [14-302(A)4&5] Easements. Provide deed book and page references for all existing easements. 15. [14-302(A)4&5] Private & Public Easements. Label all new easements as `proposed' and provide their dimensions. Proposed public easements shall be labeled as "dedicated to public use." Existing easements shall be labeled with the deed book and page number and the name of the public owner of record. 16. [14-302(A)4&5] Private & Public Easements. Label all utilities as either existing or proposed. 17. [14-317] Instrument Evidencing Maintenance of Certain Improvements. With the final plat submit the private street maintenance agreement. County Attorney approval is required prior to final plat approval. 18. [14-311] Infrastructure Improvement Plans. Road Plan and WPO Plan must be approved, all required improvements must be built or bonded, and all required Deeds and Declarations must be reviewed and approved prior to final plat approval. 19. [14-316] Vehicular Access to Site. Each entrance onto any public street shall be designed and constructed as required by the standards of the Virginia Department of Transportation. VDOT approval of the proposed entrances to the site shall be required prior to final site plan and/or final subdivision plat approval. 20. [14-303] Contents of Final Plat. A plat meeting all the requirements for final subdivision plats per the subdivision ordinance. Please contact Christopher P. Perez in the Planning Division by using cperez(a)albemarle.org or 434-296-5832 ext.3443 for further information. SRC Reviewer Comments ACSA — Richard Nelson 1. The water main along Rio Road is RWSA's. The water main is on the opposite side as shown in the plans. 2. Show RWSA existing sanitary sewer. 3. Due to the location of RWSA water main, it is recommended to make one tap and cross Rio for services on site and a FHA. Fire and Rescue — Shawn Maddox 1. The driveway/private road shall be marked no parking. 2. Does the grass surface emergency access connect to the existing driveway on Rio Road? If not a turn around shall be provided. 3. If ACSA water is available a hydrant shall be added in the area of the structures. Inspections — Michael Dellinger 1. Any structure located 5 feet or less from the property line will require fire rated construction from both sides of the wall in accordance with Table 302. 1.1 Va Residential Code. Please note on plan. E911— Elise Kiewra Comments attached. Engineering — John Anderson Comments attached. RWSA — Victoria Forte Comments attached. VDOT — Willis Bedsaul Comments attached. Christopher Perez From: Richard Nelson <rnelson@serviceauthority.org> Sent: Friday, June 29, 2018 1:26 PM To: Christopher Perez Subject: RE: SUB201800097 - RIO VISTA — PRELIMINARY Chris, Below are comments for RE: SUB201800097 - RIO VISTA — PRELIMINARY: The water main along Rio Road is RWSA's. The water main is on the opposite side as shown in the plans. Show RWSA existing sanitary sewer. Due to the location of RWSA water main, it is recommended to make one tap and cross Rio for services on site and a FHA. Thanks, Richard Nelson Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (434) 977-4511 From: Christopher Perez [mailto:cperez@albemarle.org] Sent: Thursday, June 28, 2018 1:22 PM To: Alexander Morrison <amorrison@serviceauthority.org>; Richard Nelson <rnelson@serviceauthority.org>; Adam Moore <adam.moore@vdot.virginia.gov>; Shawn Maddox <smaddox@albemarle.org>; John Anderson <janderson2@albemarle.org>; Bedsaul, Willis <willis.bedsaul@vdot.virginia.gov>; Deel, Justin <j usti n.deel @vdot.vi rgi n ia.gov> Subject: SUB201800097 - RIO VISTA— PRELIMINARY 0 SUB201800097 - RIO VISTA — PRELIMINARY Reminder SRC for the above ref project is next week, currently I have not receives any comments from you. Let me know when you anticipate to have this review completed. Thanks Christopher P. Perez I Senior Planner Department of Community Development I County of Albemarle, Virginia 401 McIntire Road I Charlottesville, VA 22902 434.296.5832 ext. 3443 Christopher Perez From: Victoria Fort <vfort@rivanna.org> Sent: Thursday, June 28, 2018 3:29 PM To: Christopher Perez Cc: Richard Nelson; justin@shimp-engineering.com Subject: SUB201800097 - Rio Vista - Preliminary Attachments: RWSA General Notes.doc Chris, RWSA has reviewed the preliminary subdivision plat for Rio Vista as prepared by Shimp Engineering, P.C. and dated 5/21/2018 and has the following comments: Sheet C2 of 3 (Existing Conditions): 1. Correctly show and label the existing RWSA 18" water main (located on the west side of Rio Road, incorrectly labeled on sheet C3 as ACSA water line). 2. Show and label the existing RWSA 42" sanitary sewer main and easement across the entire subject property. There is a second manhole located approximately 30' east of the sanitary manhole that should also be shown. Sheet C3 of 3 (Preliminary Lot Layout): 1. Correctly show and label the existing RWSA 18" water main (located on the west side of Rio Road, incorrectly labeled as ACSA water line). 2. Show and label the existing RWSA 42" sanitary sewer main, including all manholes, and the sanitary easement across the entire subject property. RWSA will need to review and approve a utility plan showing the proposed water and sewer connections and all required notes and details prior to any connection being made. All work will be subject to inspection by RWSA Staff (see RWSA General Water and Sewer Notes, attached). Let me know if you have any questions. Thank you, Victoria Victoria Fort, P.E. Senior Civil Engineer Rivanna Water and Sewer Authority 695 Moores Creek Lane Charlottesville, VA 22902 (0): (434) 977-2970 ext. 205 (F): (434) 295-1146 Rivanna Water & Sewer Authority (RWSA) General Water & Sanitary Sewer Notes Last Revised: April 2016 1. All materials and methods of construction shall comply with the latest version of the General Water and Sewer Design and Construction Standards — Version 1.0, adopted in December 2015, except as modified below or modified in special notes. 2. RWSA shall approve all construction materials and methods of construction. A preconstruction conference shall be held with RWSA prior to the start of any work. 3. The contractor shall be responsible for notifying Miss Utility (1-800-552-7001). 4. RWSA Engineer (Victoria Fort at (434) 977-2970 ext. 205) shall be notified three business days prior to the start of construction. 5. All work is subject to inspection by RWSA staff. No tie-ins to the existing system shall be made without coordination with and the presence of RWSA staff. No work shall be conducted on RWSA facilities on weekends or holidays without special written permission from RWSA. 6. For sanitary sewer line construction: RWSA may require bypass pumping for tie-ins to the existing system. All doghouse manholes must be pressure -tested before a connection is made to the system. 7. The location of existing utilities as shown on the plans is from data available at the time of design and is not necessarily complete or accurate. The Contractor shall be responsible for the verification of the location, size and depth of all existing utilities, both surface and subsurface. The Contractor shall immediately notify the Engineer of any discrepancies between the plans and field conditions. The Contractor shall use due diligence to protect all utilities and structures from damage at all times, whether shown on the plans or not. Damage to any existing utilities shall be repaired by the Contractor to the original condition at no additional cost to the Owner. 8. Erosion and sediment control facilities shall not be permitted in the RWSA easement without special written permission from RWSA. No grading shall be permitted in the RWSA easement unless permitted otherwise by RWSA in writing. 9. No blasting shall be permitted within 100 feet of RWSA facilities without written permission and RWSA approval of the blasting plan. Ground monitoring during blasting and a pre -blast survey may be required. For blasting within 100 feet of any operative RWSA sewerlines, bypass pumping and/or pre- and post -CCTV may be required. RWSA may also require certification from a licensed professional engineer stating that the proposed blasting will not damage any RWSA facilities. Damage to any utilities due to blasting shall be repaired by the Contractor to the original condition at no additional cost to the Owner. 10. The contractor shall observe minimum separation requirements for utility crossings. When a crossing is made under an existing facility, adequate structural support shall be provided for the existing pipe. The area of the crossing shall be backfilled with compacted 57 stone to the springline of the existing pipe. 11. New water main installations shall be pressure tested, chlorinated, flushed and have water samples approved prior to making any permanent connection to the public water system. Approved methods of filling and flushing new water mains will be required to prevent any contamination of the public water system. 12. All easements for new RWSA facilities shall be recorded prior to placing the new facilities into service. 13. No permanent structural facilities will be permitted in the RWSA easement. This includes building overhangs, retaining walls, footers for any structure, drainage structures, etc. 14. Trees are not permitted in the RWSA easement. 11 County of Albemarle Department of Community Development`_ 401 McIntire Road, North Wing Charlottesville, Virginia 22902 PLAN REVIEW COMMENTS - E911 APPLICATION#: SUB201800097 TMP: 06100-00-00-19100 DATE: 6/14/18 FROM: Elise Kiewra ekiewra@albemarle.org Geographic Data Services (GDS) www.albemarle.org/qds (434) 296-5832 ext. 3030 This site will require a one (1) new private road name. Per Sec. 7-200-B of the County's Road Naming and Property Numbering Ordinance (Page 2 of PDF). "It is intended by this article that all roads within the county which serve or are designed to serve three (3) or more dwelling units or business structures shall be named." Please review the procedures in the Road Naming and Property Numbering Manual to decide upon a road name for the road accessing Old Lynchburg Road. We recommend providing three (3) candidate names for each road to our office for review, in case your first choices are not acceptable. A PDF version of the Ordinance and Manual can be found here: httos://www.albemarle.ora/upload/imaaes/Forms Center/Departments/Geographic Data Service s/Forms/Road Namina and Property Numberina Ordinance and Manual.Ddf Please consult the County's Road Name Index to check your road names prior to submittal. The Index can be found here: http://www.albemarle.org/albemarle/upload/images/webapps/roads/ Parcel and mapping information can be found here: http://gisweb.albemarle.org/ If you should have any questions, please do not hesitate to contact our office. COMMONWEALTH of VIRQINIA In Cooperation with the Thomas Jefferson Health District ALBEMARLE- CHARLOTTESVILLE State Department of Health FLUVANNA COUNTY (PALMYRA) 1138 Rose HIII Drive GREENE COUNTY (STANAROSVILLE) LOUISA COONTY(LOVISA) Phone (434) 972-6219 P. O. Box 7546 NELSON COUNTY (LOVINGSTON) Fax (434)972-4310 Charlottesville. Virginia 22946 June 26, 2018 Christopher Perez, Senior Planner Albemarle County Community Development 401 McIntire Road Charlottesville, VA 22902 RE: Rio Vista Preliminary Subdivision Plat TMP: 61-191 SUB# 201800097 Mr. Perez: I've reviewed the subject plat in regard to water and sewage disposal. Since the proposed facilities will be connected to ACSA systems, I have no concerns. If there are any questions, please give me a call, 434-972-4306. Sincerely, Alan Mazurowski Environmental Health Supervisor Thomas Jefferson Health District alan.mazurowski(c�r�,vdh.vir ig nia.gov COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper Virginia 22701 Stephen C. Brich, P.E. Commissioner July 03, 2018 Christopher Perez County of AIbemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SDP -2019-00097- Rio Vista — Preliminary Subdivision Plat Dear Mr. Perez: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Shimp Engineering, P.C., dated May 21, 2018 and offer the following comments. Land Use 1. Please show mill and overlay on plans in accordance with WP -2 and show limits of mill and overlay. Also please add the detail to the plans. 2. Please provide sight distance lines and profile for proposed entrance onto RIO Road (SR 63 1) to plans. 3. Recommend dedicating prescriptive easement to the County for future public use. 4. Please provide design geometry on entrance design e.g. (radii and the entrance width). 5. Please see Road Design Manual appendix F, pg., F-105, private and low volume commercial entrances. All private and low volume entrances shall be designed in accordance with the entrance design criteria. 6. Please provide drainage information for proposed storm water management elements. 7. Low volume commercial entrance stopping sight distance is required. Please refer to the AASHTO Green Book, chapter 3, section 3.22, pg. 3-4, table's 2D-1 and 2D-2. Please provide two copies of the revised plan along with a comment response letter. If further information is desired, please contact Willis C. Bedsaul at 434-422-9866. A VDOT Land Use Permit will be required prior to any work within the right of way. The owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, Adam J. M+re P.E. Area Land Use Engineer Charlottesville Residency WE KEEP VIRGINIA MOVING Christopher Perez From: Victoria Fort <vfort@rivanna.org> Sent: Thursday, June 28, 2018 3:29 PM To: Christopher Perez Cc: Richard Nelson; justin@shimp-engineering.com Subject: SUB201800097 - Rio Vista - Preliminary Attachments: RWSA General Notes.doc Chris, RWSA has reviewed the preliminary subdivision plat for Rio Vista as prepared by Shimp Engineering, P.C. and dated 5/21/2018 and has the following comments: Sheet C2 of 3 (Existing Conditions): 1. Correctly show and label the existing RWSA 18" water main (located on the west side of Rio Road, incorrectly labeled on sheet C3 as ACSA water line). 2. Show and label the existing RWSA 42" sanitary sewer main and easement across the entire subject property. There is a second manhole located approximately 30' east of the sanitary manhole that should also be shown. Sheet C3 of 3 (Preliminary Lot Layout): 1. Correctly show and label the existing RWSA 18" water main (located on the west side of Rio Road, incorrectly labeled as ACSA water line). 2. Show and label the existing RWSA 42" sanitary sewer main, including all manholes, and the sanitary easement across the entire subject property. RWSA will need to review and approve a utility plan showing the proposed water and sewer connections and all required notes and details prior to any connection being made. All work will be subject to inspection by RWSA Staff (see RWSA General Water and Sewer Notes, attached). Let me know if you have any questions. Thank you, Victoria Victoria Fort, P.E. Senior Civil Engineer Rivanna Water and Sewer Authority 695 Moores Creek Lane Charlottesville, VA 22902 (0): (434) 977-2970 ext. 205 (F): (434) 295-1146 Rivanna Water & Sewer Authority (RWSA) General Water & Sanitary Sewer Notes Last Revised: April 2016 1. All materials and methods of construction shall comply with the latest version of the General Water and Sewer Design and Construction Standards — Version 1.0, adopted in December 2015, except as modified below or modified in special notes. 2. RWSA shall approve all construction materials and methods of construction. A preconstruction conference shall be held with RWSA prior to the start of any work. 3. The contractor shall be responsible for notifying Miss Utility (1-800-552-7001). 4. RWSA Engineer (Victoria Fort at (434) 977-2970 ext. 205) shall be notified three business days prior to the start of construction. 5. All work is subject to inspection by RWSA staff. No tie-ins to the existing system shall be made without coordination with and the presence of RWSA staff. No work shall be conducted on RWSA facilities on weekends or holidays without special written permission from RWSA. 6. For sanitary sewer line construction: RWSA may require bypass pumping for tie-ins to the existing system. All doghouse manholes must be pressure -tested before a connection is made to the system. 7. The location of existing utilities as shown on the plans is from data available at the time of design and is not necessarily complete or accurate. The Contractor shall be responsible for the verification of the location, size and depth of all existing utilities, both surface and subsurface. The Contractor shall immediately notify the Engineer of any discrepancies between the plans and field conditions. The Contractor shall use due diligence to protect all utilities and structures from damage at all times, whether shown on the plans or not. Damage to any existing utilities shall be repaired by the Contractor to the original condition at no additional cost to the Owner. 8. Erosion and sediment control facilities shall not be permitted in the RWSA easement without special written permission from RWSA. No grading shall be permitted in the RWSA easement unless permitted otherwise by RWSA in writing. 9. No blasting shall be permitted within 100 feet of RWSA facilities without written permission and RWSA approval of the blasting plan. Ground monitoring during blasting and a pre -blast survey may be required. For blasting within 100 feet of any operative RWSA sewerlines, bypass pumping and/or pre- and post -CCTV may be required. RWSA may also require certification from a licensed professional engineer stating that the proposed blasting will not damage any RWSA facilities. Damage to any utilities due to blasting shall be repaired by the Contractor to the original condition at no additional cost to the Owner. 10. The contractor shall observe minimum separation requirements for utility crossings. When a crossing is made under an existing facility, adequate structural support shall be provided for the existing pipe. The area of the crossing shall be backfilled with compacted 57 stone to the springline of the existing pipe. 11. New water main installations shall be pressure tested, chlorinated, flushed and have water samples approved prior to making any permanent connection to the public water system. Approved methods of filling and flushing new water mains will be required to prevent any contamination of the public water system. 12. All easements for new RWSA facilities shall be recorded prior to placing the new facilities into service. 13. No permanent structural facilities will be permitted in the RWSA easement. This includes building overhangs, retaining walls, footers for any structure, drainage structures, etc. 14. Trees are not permitted in the RWSA easement.