HomeMy WebLinkAboutARB201800127 Plan - Submittal (First) 2018-10-03Ipr'ojer
D1110n-
T-1-1117
arv�rnNv vvvvs
C
CRUTCHFIELD
OSpringleaf to LLARTmw
xalllr aNllvm Hertz
J O A N N RACK ROOM SHOES
SALLYBEAUTY
R010 Hill Shopping
1980 Rio Hill Center Dr. Charlottesville, VA 22901 CONSULTANTS:
Murdoch Engineering
D/F Illuminated Pylon Howell, NJ 0gb77ird
well,NJ077d 1t
(973) 570-8215
CLIENTAPPROVAL:
Issued Date: 9/26/18 DEPARTMENT APPROVAL:
TSD:
PROJECT MANAGEMENT:
PRODUCTION:
REVISION HISTORY
N0. DATE PREV DRWG I DESCRIPTION
PERMIT DRAWING
DATE:
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PROJECTTNLE:
Rio Hill Shopping Center
ORDER TITLE:
Rosenthal Properties, LLC
CITY/STATE
Charlottesville, VA
DRAWING DATE I SALES REP I PROJECT MGR.
9/26/18 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE
PROJECT TYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Cover Page
PROJECT N0. TASK N0.
QTY.
All designs indicated in these drawings are the property of Gable.
All copyrights reserved. No copies, transmissions, reproductions or
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
79128-2 168244
1
DWG. N0. SHEET
0536M RO C-100
DRAWING INDEX
REVISION HISTORY
PROJECfTYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Drawing Index
Issued /Approved Dates
Page
Drawing Type
Cover
Issued
Review Action
Issued
Review Action
C-100
DI -100
Drawing Index
GN -100
General Notes
All designs indicated in these drawings are the property of Gable.
All copyrights reserved. No copies, transmissions, reproductions or
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
79128-2
168244
GN -101
General Notes
0536M RO DI -100
SITE LOCATION PLAN
SP -100
Site Plan
SP -101
Vicinity Map
GRAPHICS/FINISHES
GF -100
Graphics/Finishes
9/26/18
Permits
STRUCTURAL
S-100
Support / Foundation
9/26/18
Permits
S-101
Mounting Plate / Install
9/26/18
Permits
ARCHITECTURAL
A-100
Fabrication Details
9/26/18
Permits
ELECTRICAL
E-100
Power Connection Diag.
9/26/18
Permits
LED Layout
Issued
Review Action
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PROJECITBLE:
Rio Hill Shopping Center
ORDERTRLE:
Rosenthal Properties, LLC
Cm/STATE
Charlottesville, VA
DRAWING DATE I SALES REP PPROJEcr MGR.
9/26/18 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE
REVISION HISTORY
PROJECfTYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Drawing Index
NO. DATE
PREVDRWG DESCRIPTION
,OJECT N0.
TASK NO.
All designs indicated in these drawings are the property of Gable.
All copyrights reserved. No copies, transmissions, reproductions or
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
79128-2
168244
1
DWG. N0. SHEET
0536M RO DI -100
General Design Drawing Notes:
1. Gable drawings and specifications remain the property of the design professional. Copies of the design drawings and specifications retained
by the client may be utilized only for his use and for occupying the project for which they were prepared, and not for the construction of any
other projects.
2. Gable's drawings are meant to be diagrammatic for type and location of fixtures and other associated devices. Exact installation requirements
to comply with all codes and regulations as determined by the architect of record, electrical engineer and structural engineer. All design
documentation and installation should comply with applicable codes. The notes on this page are meant to clarify the project design
documentation and requirements.
3. It is assumed that the Gable project design team has reviewed the documentation and shall communicate any conflicts in the design
documentation.
4. Contractor/ fabricator shall not deviate from Gable's design drawing details. Any modifications must be reviewed and approved by Gable.
General Engineering Notes:
1. Steel design and fabrication shall be in accordance with AISC, 14th edition
2. Round & square/rectangle HSS shall be ASTM A500 Grade B.
3. Plate, angles and channels steel shall be ASTM 36.
4. Wide flange and tees (WT) shall be ASTM A992.
5. Shall discrepancies exist between the plans and actual conditions, contact Engineer of Record (EOR) for design review and/or revision.
Steel Welding Notes:
1. Welding shall be in accordance with AWS D1.1
2. AWS certification required for all structural welders
3. E70XX electrodes for SMAW process.
4. F7X-EXXX electrodes for SAW process.
Aluminum Welding Notes:
1. Welding Shall be in accordance with AWS D1.2
2. Aluminum alloy filer 4043 shall be used in all structural welds.
3. Fillet weld size shall not exceed thinnest member thickness of joined sections.
4. Welding process GMAW or GTAW shall be in accordance with AWS D1.2
General Lighting and AV Installation Notes:
It is intended that the installing contractor shall:
1. Bid, provide and install all fasteners, hanging rods, support elements, anchors, safety/ seismic materials, miscellaneous metals, etc. that are
not indicated as being
2. Complete all terminations and verify continuity and consistency of all low voltage and data communication systems.
3. Be responsible for the supply and installation of all additional material to ensure the safe and reliable operation of all emergency lighting and
audio systems.
4. Be responsible for the supply and installation of plugs and cord caps where required. owner provided.
5. Be responsible for the installation of any and all lamps, color filters, screens, safety cables, louvers and diffusers in accordance with the
lighting design drawings.
6. Be responsible to supply and install all low voltage transformers and associated low voltage gear as required.
7. Focus all lamps and fixtures per the design drawings, or, if no focus indication is shown, focus all downlights straight down.
8. Be responsible for making their own quantity counts for all equipment that they are asked to supply including modifications to quantities to
match field conditions.
9. Be responsible for supplying clean power to all control and dimming equipment and to install any necessary equipment to avoid power
variations.
10. Provide strain -relieved and weatherproofed exterior connections/ terminations.
11. Utilize manufacturer shop drawings and instructions for energization prior to system commissioning. Improper turn on of system may void/
alter manufacturer warranty. Electrical contractor will require written authorization from manufacturer prior to commissioning.
12. Install dimmer racks in accordance with manufacturer's specifications and shop drawings.
General Control, MDF, IDF Room Notes:
1. All control rooms shall be locked, clean and dry with finished, painted and sealed walls, floor and ceiling.
2. Each freestanding, dimming, and control rack requires T of clearance in front and above each rack. Additional clearance requirements will be
shown on control room layout page.
3. Each control/ dimming/AV room requires a minimum of 10' finished ceiling height. of record.
4. Gable recommends a sub -floor and/or cable tray a minimum of 96 inches above finished floor mounted over the control racks.
5. All main control room access doors must be oversized with a minimum of 7' high clearance.
6. Floor mounted racks to be placed on a 4" pad above finished floor.
7. Main power feeds should have a local breaker/disconnect switch installed next to each dimmer/relay rack. Power protection device must be
specified by the engineer
8. Gable is not responsible for the design and integration of backup power systems for control racks.
9. The control and dimmer room environment must maintain a temperature at 70° f (20° c) and humidity at less than 50% and provide air filtration
that removes 95% of all particles 0.5 microns in size or larger. Systems shall be operational prior to commissioning.
10. Electrical engineer to provide lighting in control room(s) to meet a minimum of 20 -foot candles.
11. Minimum of 6 convenience outlets (duplex style, 20 -amp) shall be provided in each control room separate from equipment racks.12.
12. Gable recommends that no overhead sprinkler system be installed in the control/ dimming room(s).
General Data Communication, Low Voltage and AV Wiring Notes:
1. A wired high-speed Internet connection must be provided to main control room.
2. All fiber optic infrastructure including all fiber patch panels and modular patch cords require connectors per equipment specifications to be
provided, installed and terminated by certified contractor prior to rack commissioning.
3. No changes or substitutions shall be made to Gable's cable/ equipment specifications, or documentation without written permission.
4. Gable recommends 20% spare conduit capacity and an additional spare home run for the main infrastructure. All cable infrastructure and
wiring must adhere to manufacturer specifications and shop drawings.
5. Gable recommends against the use of GFI protection on loads related to theatrical lighting, AV, and special effects.
6. The engineer shall provide individual load calculations that adhere to all local codes and dimming equipment specifications as well as all
appropriate infrastructure,
7. All data wires and control cables pulled into equipment/ control rooms shall be left with a minimum service loop of 12' in each rack location
and minimum of Vin all feeds and switch gear.
8. Each circuit must have an independent hot, neutral, and ground. No sharing of hot, neutral, or ground shall be permitted.
9. All control & low voltage cable home runs cannot be spliced. Feld locations.
10. The engineer should allow for 4" minimum distance between high and low voltage conduits. High and low voltage conduits must cross at
90 -degree angles.
11. All cables must be labeled in accordance with Gable's drawings and other furnished documentation.
12. Final cable specifications to be approved by electrical engineer. Installing contractor must verify maximum length of all cable runs prior to
installation. If run exceeds maximum cable length of manufacturer and/or product specification, installing contractor to provide alternate
wiring methodology or specification for review by Gable
13. All splices for exterior fixtures must be made in suitable waterproof junction boxes, with conduits sealed against water intrusion.
14. All ground recessed exterior fixtures must be installed to manufacturer's specific instructions, particularly regarding drainage, sealing and
potting.
15. All electrical junction boxes are to be provided by the electrical contractor as the point of connection within 6 feet of the sign. and electrical
engineer.
16. All electrical connections to the sign shall be made by a Gable Representative.
17. All electrical connections are to be made in accordance with the requirements of the National Electrical Code (N.E.C.) in addition to all
applicable local codes.
18. All installation standards for high and low voltage systems, control and data cabling, and terminations must meet and comply with USITT,
BICSI, AES, NFPA and NEC standards. Standards may be found at:
WWW.NFPA.ORG
WWW.USITT.COM
WWW.AES.ORG
WWW.BICSI.ORG
General Installation Notes:
1. Installer shall be responsible for determining the erection, maintenance and dismantling of all barricades or protective coverings necessary to
safeguard the public and property during the performance and duration of the work.
2. Installer shall attach components to substrate in accordance with the structural engineers and manufacturer's instructions unless otherwise
shown. Install level, plumb, and at the proper height. No movement of signs at their foundations shall occur, the components must remain
true and plumb on their foundations.
3. Installation includes provision of any required footing, all anchor bolts, fastenings, attachment metal, and other miscellaneous metal items
embedded in concrete or building wall material as required, and security of components.
4. All items to be installed shall be left in a clean condition.
5. Upon completion of the installation of each component, clean all soiled surfaces and touch-up all imperfections that may have occurred
during the time of handling and installation.
6. All debris and packing material shall be removed and disposed of in a legal manner. All protective masking of the surfaces shall be removed
upon completion of the installation.
7. Gable is not responsible for the design or implementation of emergency and life safety systems.
8. All excavation and site work shall be returned to its original grade configuration after contract items are installed.
9. All atypical installation conditions encountered by the installer must be brought to the attention of appropriate Gable personnel.
10. Installer is responsible for compliance with all OSHA requirements and regulations.
11. Installer is responsible for compliance with all applicable environmental regulations.
REVISION HISTORY
I NO. I DATE I PREV DRWG I DESCRIPTION I
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PfUECTNU:
Rio Hill Showing Center
ORDERTTTLE:
Rosenthal Properties, LLC
Cm/STATE
Charlottesville, VA
DRAWING DATE I SALES REP I PROJECT MGR.
9/26/18 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE:
PROJECTTYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
General Notes
;OJECT N0. I TASK NO. ..
All designs indicated in these drawings are the property of Gable. 79128-2 1 168244 1
All copyrights reserved. No copies, transmissions, reproductions or DWG. N0. SHEEi
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable 0536M RO GN -100
General Concrete Foundation Notes:
1. Engage a private utility locating specialist and mark existing utilities in proximity to sign foundation before excavation. Likewise, contact Miss
Utility for marking of all public utilities in the work area.
2. Excavate for sign foundation to elevations and dimensions indicated. Reconstruct sub -grades that are un -firm, disturbed, or composed of
unsuitable soil, or has been damaged by freezing temperatures, frost, rain, accumulated water, or construction activities by excavating
further, backfilling with satisfactory soil or fill, and compacting to original sub -grade elevation. Do not install footings in damp or saturated
soils. Do not leave open excavation during off -work hours.
3. Install concrete footing with reinforcement, foundations, and other embedded items required for installation of signs, as approved by
contractor -furnished Engineer.
4. Set core drill and set anchors bolts from footing base plate onto non -shrink grout leveling bed. Ensure post is level and plumb, and at heights
indicated, with surfaces free of distortion and other defects in appearance.
5. Coordinate and install power source feed wire from adjacent sub -grade and form bend of conduit chase (sweep) into foundation pour. Verify
size requirements prior to
6. Back fill footing/foundation once concrete reaches 3000 -pound compressive strength. Backfill material shall be free of litter, debris and
organic matter. Backfill installation. material shall have not more than optimum water content prior to compaction operations, soils to dry to
suitable levels if over- saturated.
7. Minimum concrete strength shall be 3,000 psi, w/ 6% air entrainment unless otherwise noted.
8. Concrete design & construction to be in accordance with ACI 318-05
9. Concrete poured into constrained earth excavations must be cure under proper conditions for four days prior to sign box installation.
(Exception: if the overall height of the sign is less than 20 feet and the sign pole(s) are adequately braced as necessary against wind loads
for a minimum of 4 days, the box may be installed the same day as the footing is poured.
10. For pier and caisson footings, concrete must be poured against undisturbed earth.
11. Maintain a minimum of 3" cover over all embedded steel.
12. Provide a maximum of 4" cover between the bottom of support pole and bottom of the concrete footing on all direct burial footings. (Unless
otherwise noted)
13.If clay, silt or organic soils are encountered upon excavation it is the installing contractor's responsibility to contact a licensed civil engineer for
design modification.
General Electrical Grounding Notes:
1. The single point ground system (SPGS) is a grounding mandate that all major components of the building safety protection system to be
designed and bonded to a single ground reference point. These components consist of ground electrodes, grounding electrode conductors,
grounded conductors, and grounding conductors. These conductors are designed to create the path of least resistance/impedance. This
allows any voltage produced as current to flow or return to its source along the proper designated path.
2. Connections to the SPGS will reduce voltage potential differences among various types of equipment. This should reduce personnel safety
hazards, protect the equipment and reduce noise currents that may affect the operation of voltage -sensitive equipment. This includes
equipment such as communication switching equipment and any computer -controlled equipment.
3. The SPGS has one main connection point. The single ground reference point is usually designated as the master ground bar (MGB).
4. Grounding conductors and their grounded components must be isolated from any unintended contact with other grounding conductors and
grounded components except at the single ground reference point, the MGB. Any unintended points of contact among different grounding
conductors and components create ground loops within the SPGS and are violations of the SPGS.
5. All computer, network, data and audio related field connected devices must have their grounds referenced to the control room where their
source outputs will be connected.
6. The ground reference differential must not exceed 2 volts. Levels higher will result in degradation in performance and damage to the
connected device(s).
General Manufacturing Notes:
1. Details depicted on the construction documents shall be followed for exterior appearance.
2. Approved Structural design shall utilize self -supportive framing.
3. Fabrication of cabinet, exposed faces and graphics devices to size and style indicated and produced surfaces free from oil canning, warping,
distortion or any irregularities or inconsistencies. Include internal bracing for stability and attachment of mounting accessories as required.
4. Fabricator may change interior construction shown on these details to conform with general shop practices. However, these changes must be
submitted to TSD as part of the shop drawings and be reviewed by TSD and noted prior to fabrication.
5. Construct all work to eliminate burrs, cutting edges and sharp corners.
6. All welding must be performed by operators who are currently qualified by tests as prescribed in AWS D.1.1, and or D.1.2 as applicable, and
recognized building code authority.
7. Make all signs tight fitting, between parts and sections, and with adjacent surfaces.
8. Unless indicated otherwise, non -welded joints between various portions of signs must be weatherproof (for exterior signs) and have tight,
hairline -type appearances, without gaps (varying or otherwise). Provide sufficient fastenings to preclude looseness, racking, or similar
movement.
9. Conform to manufacture's recommended fabricating procedures regarding fastening, restraining, expansion and contraction of dissimilar
materials.
10. Isolate dissimilar materials to prevent galvanic corrosion by means of rubber pads/washers and utilize inert (stainless steel) fasteners.
11. Signs to be assembled and mounted so as to provide reasonable ease of access and replacement of all components.
12. Aluminum sheet not less than .125" unless noted otherwise, fabricate by MIG welding, filled and ground smooth, unless the seam occurs
along a color break. Then a clean butt joint with concealed backing channel and plug weld is acceptable.
13. All bends, curves, and folds to be geometrically correct and produced by a consistent mechanical method unless approved otherwise.
14. Jointing and brake forming all sheet metal shall have brake formed edges with radii not greater than sheet thickness unless otherwise
specified. Adjacent stock shall have edges with similar radii.
15. Welding on all exposed welds is to be ground smooth to match surface of adjacent material.
16. All mounting patterns and or templates shall have at least a fully marked base line and center line depicted on the pattern.
General Vinyl Graphics Application Notes:
1. Sign copy to comply with the requirements indicated for size, proportion, style, spacing, content, position, material, finish and color of letters,
numbers, symbols and other graphics devices.
2. All letter forms shall be aligned so as to maintain a baseline parallel to the sign format, with margins and layout as indicated on design
drawings and approved shop drawings.
3. Routed copy: Cutting and routing shall be done in such a manner that edges and corners of finished letter forms shall be sharp and true.
Letter forms with nicked, cut, ragged, rounded positive or negative corners, and similar disfigurements will not be acceptable. Letter forms
shall be aligned so as to maintain a base line parallel to the sign format. Vertical strokes shall be plumb. Mechanically fasten center of letters
to acrylic plastic as required.
4. All high resolution large format digital printing shall be protected with a UV over laminate.
General Spray Finishing Notes:
1. Pre-treatment: All surfaces shall be sanded, cleaned, primed, and pre-treated as required prior to finishing.
2. Paint: Paint shall be manufacturer's highest grade for best ultraviolet light resistance, weather ability and overall longevity of finish and color
pigmentation retention.
3. Paint color mixtures shall be cross checked with approved color control samples, prior to the final finishing process.
4. All painted surfaces shall be free from particulates, blemishes, dry spots, orange peel and unevenness of spray patterns.
5. There shall be no de -lamination of any parts of the sign or of the lettering from the sign face.
6. There shall be no cupping, warping, or dishing in excess or other disintegration of the sign face.
Verify In Field (V.I.F.):
Where "Verify In Field" (V.I.F.) is found in this drawing, the GABLE project manager will assign tasks to "Verify In Field" and
submit information / results back to the GABLE technical team.
SYMBOLLEGENDS:
Elevation
Look Point
REVISION HISTORY
I NO. I DATE I PREV DRWG I DESCRIPTION I
All designs indicated in these drawings are the property of Gable.
All copyrights reserved. No copies, transmissions, reproductions or
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PfUECTNU:
Rio Hill Showing Center
ORDERTTRE:
Rosenthal Properties, LLC
Cm/STATE
Charlottesville, VA
DRAWING DATE I SALES REP I PROjEcr MGR.
9/26/18 1 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE:
PROJECfTYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
General Notes
;OJECT NO. TASK NO.
79128-2 168244 1
DWG. NO. SHEET
0536MRO GN -101
WI -
IZ3MG���>� IAds �O >o� y��'L� pq o A 10O�v��
co. -ti '� V r OW
r009�j0
s° Os>�
Tc'TCp 'pd dd��d9 pG�
0919sQ o aos
N �Op vC, O9 �1
SITE PLAN
1SCALE: 1" 1100'
�T'LF9 �9�`d�`r
� �tiS�cf�,y�
<1 <
<<
<< S`ry °F9 %`
<<'
!& sti9prgeo 9�
yS,r'SegSOS�OS�T., \
9S aoo�6' • 0 1., �.'� O
6S • 059T Ts
�0S
9G? �B�lyS S`50000,
S0 000
O GO TT O�
"'o-0001
0 O
0000
y S �
q 9
d/f pylon location
A
PROJECTTYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Site Plan
NO. DATE
PREVDRWG DESCRIPTION
O
2
a
v
TASK NO.
All designs indicated in these drawings are the property of Gable.
All copyrights reserved. No copies, transmissions, reproductions or
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
79128-2
approx. 20' to property line
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PROJECTTI I.E:
Rio Hill Shopping Center
ORDERTfI-E:
Rosenthal Properties, LLC
Cm/STATE
Charlottesville, VA
DRAWING DATE I SALES REP I PROJECT MGR.
9/26/18 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE
REVISION HISTORY
PROJECTTYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Site Plan
NO. DATE
PREVDRWG DESCRIPTION
,OJECT N0.
TASK NO.
All designs indicated in these drawings are the property of Gable.
All copyrights reserved. No copies, transmissions, reproductions or
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
79128-2
168244
1
DWG. N0. SHEET
0536M RO SP -100
d/f pylon location
VICINITY MAP
t SCALE: N.T.S.
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PROJECTTrrLE:
Rio Hill Shopping Center
ORDERTITLE:
Rosenthal Properties, LLC
Cm/STATE
Charlottesville, VA
DRAWING DATE I SALES REP I PROJECT MGR.
9/26/18 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE
REVISION HISTORY PROJECT TYPE:
DATE I PREVDRWG I DESCRIPTION D/F Illuminated ID Pylon
DRAWING TYPE:
Vicinity Map
PROJECT NO. TASK NO.
All designs indicated in these drawings are the property of Gable.
79128-2 168244
1
All copyrights reserved. No copies, transmissions, reproductions or
DWG. N0. SHEET
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
0536M RO SP -101
4'-0" 1'-0"
6" 6" 6 l
non-illumianted fabricated
_ j 4aluminum face/returns painted to
match gray (PM to provide color)
0
L-0 '
Iro er
DICIC'S
SPQRTiNO OQOOS
Tojemcuk
CRUTCHFIELD
-I1 OOL _4R rru
routed and backed illuminated
AA►Hertz
N 1 I�
RACKROOMSHOES
BEAUTY
logo/underscore w/ #7328 white
acrylic & 3M #3630-217 Deep Sea
Blue trans. vinyl applied
Q0
routed and backed illuminated
copy w/ #7328 white acrylic
M
roger
1-Y2" alum. retainer/divide bar
�
Dicirs
painted to match gray
(PM to provide color)
M
SPQRTIRO OOOOS
Q?
_Q
m
T��m ,�
illuminated tenant panels to be
fabricated #7328 white acrylic
w/ full color logo digital trans.
vinyl print applied
CRUTCHFIELD
weatherproof disconnect switch
painted to match light gray
ti
OSpringleaf
10 DOLLAR TRELE
(PM to provide color)
® Mir anrerir
Hertz
ti
support covers painted to match blue
J OA N N
RACK ROOM SHOES
(PM to provide color)
ti
m
SALLY BEAUTY
_
ao
non -illuminated fabricated alum.
base painted to match light gray
`6
I
(PM to provide color)
W
i
ML
non -illuminated fabricated alum.
base painted to match gray
(PM to provide color)
2'-0"
1 ELEVATION DETAIL
SCALE: 1/2" = 1'
(SIDE A) -TOTAL SF = 54
(AIDE DETAIL
SCALE: 1/2"= 1'
L-0 '
Iro er
DICIC'S
SPQRTiNO OQOOS
Tojemcuk
CRUTCHFIELD
-I1 OOL _4R rru
EOSpringleof
AA►Hertz
N 1 I�
RACKROOMSHOES
BEAUTY
nELEVATI0N DETAIL (SIDE B)
SCALE: 1/2" = 1'
1'-2" (bqse)
I I
I I
I I
I I
I I
I
I
I
I
I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I I
I I
SIDE DETAIL
4 SCALE:1/2" = 1'
REVISION HISTORY
DATE I PREV DRWG I DESCRIPTION
All designs indicated in these drawings are the property of Gable.
All copyrights reserved. No copies, transmissions, reproductions or
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PROJECTTIfLE:
Rio Hill Shopping Center
ORDERTITLE:
Rosenthal Properties, LLC
CITY/STATE
Charlottesville, VA
DRAWING DATE SALES REP PROJECT MGR.
9/26/18 1 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE
PROJECTTYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Graphics / Finishes
PROJECT N0. I TASK NO. QT
79128-2 168244 1
DWG. NO. SHEET
0536MRO GF -100
1 1
10'-0" VIF
ELEVATION DETAIL
1 SCALE: 1/2" = 1'
l
8'-6" VIF
SIDE DETAIL
(AIDE
1/2" = 1'
. routed alum. face
novable on one side
s. screws
de to be chemically welded*
'MU blocks to be excavated
s footer below
D be backfilled after
Lion*
#5 rebar cage @ 16" D.C.
,olid concrete footer
Asting footer previously
ed an approx. 540 total
'ick pylon (38' total height)*
. PVC electrical conduit
s' electrical contractor;
tion & location on site
1SION HISTORY
vr. n
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PROJEC TLE:
Rio Hill Shopping Center
ORDERTnLE:
Rosenthal Properties, LLC
CfIY/STATE
Charlottesville, VA
DRAWING DATE I SALES REP I PROJECT MGR.
9/26/18 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE
PROJECTTYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Structural -Support/ Foundation
PROJECT NO. TASK NO.
QTY.
All designs indicated in these drawings are the property of Gable.
79128-2 168244
1
All copyrights reserved. No copies, transmissions, reproductions or
DWG. N0. SHEET
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
0536M RO S-100
MOUNTING PLATE DETAIL
1 SCALE: 1-%" = 1'
3'-0"
2'-6" D.C.
O O 3/4" thk. aluminum plate
i
i
qty. (6) 9/16" dia. pre -drilled holes
O
—, ,nx , in" ., 0..
long s.s.
200 adhesive system
�r manf. recommendation)
SIDE DETAIL
2 SCALE: 3" — 1'
Typ.
ral grout
REVISION HISTORY
DATE I PREV DRWG I DESCRIPTION
All designs indicated in these drawings are the property of Gable.
All copyrights reserved. No copies, transmissions, reproductions or
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PROJECTTIR.E:
Rio Hill Shopping Center
ORDER TITLE:
Rosenthal Properties, LLC
Cm/STATE
Charlottesville, VA
DRAWING DATE SALES REP I PROIECI MGR.
9/26/18 1 GG GG
ENGINEER OF RECORD SEAL/SIGNATLIRE/DATE
PROJECfTYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Structural - Mounting Plate/Install
DJECT N0. TASK It _ QTY
79128-2 168244 1 1
DWG. N0. SHEET
0536MRO S-101
-- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — \
i
I �
I I
I
I I I
I
----------------------------------------------------------------------------------------------------------------------------------- -----
—
I I
I -
C14 I
I Q I
I I
I I
I I
I I
I I
I I
I
I I
I I
I
I I
I I
I o
— 0
I I
O O I
I I
1 �
i
`\�-----------------=-------------==------- -----— ---�/
ENLARGED SIDE DETAIL
1 SCALE: %" = 1"
----------------- -----------------,—--------
/
i
- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J L - — — — — — — — —
f
I
I
I
I
I
I
I
I
� 0 0
� 0 0
nENLARGED SIDE DETAIL
` SCALE: 1/2" = 1"
6"
E��D PLAN DETAIL
SCALE: 3" = 1'
alum. retainer (EMS #24-63-909)
*in stock*
12" sign frame extrusion (EMS #24-63-910)
*in stock*
3/16" thk. acrylic tenant panels
3/16" \Typ'
angle pole pocket
.063" alum. panel for mounting
LED modules
#8 x 3/4" long s.s. tek screw
1-W double tee divider bar
(EMS SF17-1 24-63-120)
qty. (4) .063" break formed alum.
escutcheon cover - secure w/ #10
x 3/4" wafer head screws
sq. alum. supports
(see detail "1" on sheet S-100)
1/8" thk. alum. face
GE -1000 clear silicone @
top & sides only
3/16" thk. 7328 white diffuser
acrylic panel on back
10-24 x 3/4" alum. stud
welded to back of face
w/ flanged push nut
(McM #90533A117)
nROUTED/BACKED SIDE SECTION - "RIO HILL CENTER/
Y SCALE:1/2"=1' LOGO FACES
REVISION HISTORY
DATE I PREV DRWG I DESCRIPTION
All designs indicated in these drawings are the property of Gable.
All copyrights reserved. No copies, transmissions, reproductions or
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PROJECTTM.E:
Rio Hill Shopping Center
ORDERTI'll
Rosenthal Properties, LLC
CITY/STATE
Charlottesville, VA
DRAWING DATE SALES REP I PROJEcr MGR.
9/26/18 1 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE
PROJECTWPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Arch. - Fabrication Details
PROJECT NO. TASK NO.
79128-2 168244 1
DWG. NO. SHEET
0536MRO A-100
Listed Sin or Sign Section 600.3
-All electric signs shall be listed &
installed in conformance with that
listing
-Channel Letters with LED's, power
supply and a disconnect switch
-Acceptable for wet, damp or dry
locations.
■ EXTERIOR
❑ INTERIOR
NOTE: UL
CLASS 2 POWER SUPPLIES THAT HAVE NO PROVISIONS FOR
ATTACHMENT OF EQUIPMENT GROUND ON THE LINE SIDE
OR SECONDARY SIDE REQUIRES A METAL ENCLOSURE.
LED CIRCUITS FOR SIGN LETTERING PRESENTLY ARE
GENERALLYAL DC. BECAUSE OFTHIS, MANY LED COMPONENT
MANUFACTURERS ARE USING BLACKWIRE FOR THE GROUND,
WHITE FOR NEGATIVE OR NEUTRAL SIDE AND RED FORTHE
POSITIVE SIDE. READ POWER SUPPLY INSTRUCTIONS CAREFULLY.
THE NEC 2005 ELECTRIC CODE ARTICLE 250, ARTICLE 600
AND ARTICLE 725 REQUIRE THAT ALL NON-CURRENT CARRYING METAL PARTS
INCLUDING THE METAL LETTERS OF A SECTION SIGN MUST BE GROUNDED.
THIS INCLUDES LOW VOLTAGE CIRCUITS OF LED ILLUMINATED SIGNS.
MAKE SURE TO READ AND UNDERSTAND THESE SECTIONS PRIOR TO INSTALLATION
,ELEVATION DETAIL
1 SCALE: 1/2" = 1'
standard GABLE white LED modules
-qty: 46 per side (92 total)
.063" alum. panel for mounting
LED modules
standard GABLE white LED modules
-qty: 100 per side (200 total)
*qty: 292 for entire sign*
one side of alum. fabricated base to be
removable for elect. access/ installation
using c.s.s.s. screws
weatherproof disconnect switch (by GABLE)
*located on same side as highway
(PM to confirm location)*
qty. (4) H60W-PPSE (IP67) power supplies
one (1) 20amp/120v dedicated circuit brought to sign by owner's E.C.
*feed direction to switch & coordiation by owner's E.C.*
shelf to house power supplies fabricated
from bent .063" alum.
VOLTAGE
AMPERAGE
CIRCUIT INI
REVISION HISTORY
DATE I PREV DRWG I DESCRIPTION
A VISUAL
SOLUTIONS
COMPANY.
7440 Fort Smallwood Road
Baltimore, Maryland 21226
800.854.0568
PROJECTU LE:
Rio Hill Shopping Center
ORDERTnLE:
Rosenthal Properties, LLC
CfIY/STATE
Charlottesville, VA
DRAWING DATE I SALES REP I PROJECT MGR.
9/26/18 GG GG
ENGINEER OF RECORD SEAL/SIGNATURE/DATE
PROJECT TYPE:
D/F Illuminated ID Pylon
DRAWING TYPE:
Electrical
PROJECT NO. TASK NO.
QTY.
All designs indicated in these drawings are the property of Gable.
79128-2 168244
1
All copyrights reserved. No copies, transmissions, reproductions or
DWG. N0. SHEET
electronic manipulation of any portion of these drawings in whole or in part
are to be made without the express written permission of Gable
0536M RO E-100