Loading...
HomeMy WebLinkAboutWPO201800030 VSMP - SWPPP 2018-10-18OF AL� COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 £ Tel. (434) 296-5832 * Fax (434) 972-4126 VI�Iri1P Stormwater Pollution Prevention Plan (SWPPP) For Construction Activities At: Project Name: Charlottesville Albemarle SPCA WP0201800030 Address: 3355 Berkmar Dr Charlottesville VA 22901 Prepared by: Name: Timmons Group Prepared for: Name: Albemarle Society for the Prevention of Cruelty to Animals Inc SWPPP Preparation Date: May 4, 2018, Revised October 12,2018 NOTE: FOR REVIEW PURPOSES ONLY. SWPPP TO BE FINALIZED PRIOR TO PLAN APPROVAL/LAND DISTURABANCE APPLICATION (This document is to be made publicly available according to 9VAC25-880-70, Part II, section D) Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County CONTENTS: (from Albemarle County Code Sec. 17-405) 1. Registration statement 2. Notice of general permit coverage 3. Nature of activity 4. Erosion and Sediment Control Plan. 5. Stormwater Management Plan 6. Pollution Prevention Plan. 7. Discharges to impaired waters, surface waters within an applicable TMDL wasteload allocation, and exceptional waters. 8. Qualified personnel 9. Signed Certification 10. Delegation of authority. 11. General permit copy 12. Inspection logs Issued— 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 1. Registration statement (Provide a signed completed copy of the DEQ registration statement) Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Registration Statement General VPDES Permit for Discharges of Stormwater from Construction Activities (VAR10) (Please Type or Print All Information) 1. Construction Activity Operator: (General permit coverage will be issued to this operator. The Certification in Item #12 must be signed by the appropriate person associated with this operator.) Name: Albemarle Society for the Prevention of Cruelty to Animals 2. 3. Contact: Angie Gunter Mailing Address: Po Box 7047 City: Charlottesville Email address (if available): agunter@caspca.org State: VA Zip:22906 Indicate if DEQ may transmit general permit correspondence electronically: Yes ❑- Existing General Permit Registration Number (for renewals only): Name and Location of the Construction Activity: Name: Charlottesville Albemarle SPCA Address (if available): 3355 Berkmar Dr City: Charlottesville State: VA Phone: 434-973-5959 No ❑ County (if not located within a City): Albemarle County Latitude (decimal degrees): 38.092566 Longitude (decimal degrees): -78.473794 Name and Location of all Off -site Support Activities to be covered under the general permit: Name: Zip:22901 Address (if available): City: State: Zip: County (if not located within a City): Latitude (decimal degrees): Longitude (decimal degrees): 4. Status of the Construction Activity (check only one): Federal ❑ State ❑ Public ❑ Private ❑■ 5. Nature of the Construction Activity (e.g., commercial, industrial, residential, agricultural, oil and gas, etc.): Animal Shelter 6. Name of the Receiving Water(s) and Hydrologic Unit Code (HUC): Name: Rivanna Name: H UC: 02080204 H U C: 7. If the discharge is through a Municipal Separate Storm Sewer System (MS4), the name of the MS4 operator: County of Albemarle 8. Estimated Project Start and Completion Date: Start Date (mm/dd/yyyy): 05/01/2019 Completion Date (mm/dd/yyyy): 05/01/2024 9. Total Land Area of Development (to the nearest one -hundredth acre): 8.88 Estimated Area to be Disturbed (to the nearest one -hundredth acre): 2.5 10. Is the area to be disturbed part of a larger common plan of development or sale? Yes ❑ No ❑■ 11. A stormwater pollution prevention plan (SWPPP) must be prepared in accordance with the requirements of the General VPDES Permit for Discharges of Stormwater from Construction Activities prior to submitting this Registration Statement. By signing this Registration Statement the operator is certifying that the SWPPP has been prepared. 12. Certification: "I certify under penalty of law that I have read and understand this Registration Statement and that this document and all attachments were prepared in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief true, accurate, and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment for knowing violations." Printed Name: Title: Signature: Date: (Please sign in INK. This Certification must be signed by the appropriate person associated with the operator identified in Item #1.) 07/2014 Page 1 of 1 Section 2. Notice of general permit coverage (This notice is to be posted near the main entrance according to 9VAC25-880-70, Part II, section C.) (Provide a copy of the DEQ coverage letter when obtained) Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 3. Nature of activity (Provide a detailed narrative of the construction activities. Include or reference a construction schedule and sequence. Include any phasing.) This Project involves the construction of several building additions and two parking lots and associated site work. Limits of Clearing and Grading are 2.5 Acres. The project is anticipated to begin construction in May 2019 and be completed prior to May 2024. Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 4. Erosion and Sediment Control Plan. (Provide a reduced, 11x17 copy of the latest Erosion and Sediment Control Plan. Do not reference only.) Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County c 0 0 T a co 0 0 N 0 0 m 0 d 3 w U) Q 2 d ,� \ / I ,14 ' '- - CROCK ARMOR / \ �, ' '� ' / r '/ C RB INLET, / MHD _�,�'//// \OP514.3a / /i// "1 <- �� I \ �/ INV. OUT-510c 75' 15" R IP _ I \ --- WIgRATE TOP/(G ATE)=513. 8 ZSF\ TiZ O IN 510.30 1 � RCP (NORTH ' _ - _ _ l l=510.43' 5" RCP (WEST) V. UT=510. 5 15 RCP __--, (`\ \`\� \/ �e6NTRA FOR /)-' %////r/ /r/�// /• __ P,ARKINGAREf4. ///�'//il; IP� 0 1 I I �/S 543-- r / ' ' I I I I / US STOIGN \ 6' / + / / _ - - , , - - _ ` /COC►RDINAYE WI H / / / r/r ,/ F I I / J CCM _ 16\?VNERA RC/ -STR �'- ■ ■ \ - IP � 6yb -' - �/ / 15 RCPc ` r/ irh. I , ti( o o c� \ \ \ \\\ / �i / /i /� / /i� SQ CURB 11yL EST WX ��// / / �\ /'' " _ - _ ♦ W - \\\� „I��,, z \ INV,iYN= 19.�12 ►15 RC/P r 1„ , �I VV. OU, =519. d2 15 f? � I / / / /, \\ \ ,Q ,( � OP=510.72 FFE=543.46'\\ ` ®\ ' \ r r / r� r y `�¢ ' ' �' i i I I h ' '/i ' \ `\ c')" / ' INV. 1N=507.56' 18" RCP (EAST \\ \ /��, / f/ I /��P /: , / �h\'\� u / ^ INV. IN=507.30' 18" RCP (WES _ \\ FFE=543.46 ■ � J 5 / / 0 "/' ' / r , %`� / ''\ \\ ` INV. OUT=506.62' 18"RCP 543.46' FFE=543.4T \ I I ' '/ P ' ` ' / / / / // // �/ / I/� ' \8 \ \ \ \ \ STR A FFE=543.46' / - / / I / \�, C - / / r ' / / , / / / / /� / \ / // SD CURB INLET W/GRATI \ \ 'x / FFE=543.49 ■ k\--------- %/ r, / /�/ , �` /' ' /' // / EXCAVATED DROP INL / ( )- \ / FFE=543.44 J / / / / TOP GRA TE =510. 39 \ \ \ FFE=543.47' ' � � P, \ - / / / / / / / r / / / , \ \ _I� / / ///j // \ \ \ FFE=543.42 \ R D / , , / / \ \ �/ DC - - T �` I // /� / / r r / SEDIMENT TRAP #1 ' INV. OUT=507.89 18 RCL BOTTOM ELEVATION = 529.47 I I / / ,/` / / /, / - SD CURB INLET W/GRA / ' '; i >\' ` r �/� TS / / / / % j / / INLET TOP = 531.47 \ r �- - // / �// DRAINAGE AREA = ODD AC _ / / / \ `.� I - 1 . \ / / TOP GRATE-511.34' I I II I r ` ' ' r l / REQUIRED VOLUME: ( ) ■ I / 8" W �' CE } _ / �I / � / / / // / / � INV. 1N=508.81' 15" RCP i 2 STORY / -� /� 0.30 AC X 134 CY X 27(CF/CY) = 1087.15 CF , III I \ VOLUME PROVIDED = 1265 CF IINV. OUT=508.41' 18"R( ` \ \ ` \ ` FFE=543.49' BLOCK & HARDI-PLANK BUILDING FFE=543.47' III I \ \ \ \/' �/ _ ♦ / / / / /,/ / / (CASPCA FACILITY) }I / BOTTOM LENGTH = 20.4' _ _ - - _ , / - - - \ \• 3355 BERKMAR DRIVE I , -- - _ _ _I / "�', /' / 5A0 BOTTOM WIQ/TH = 17.2' CO ,9649\ / ______-/d- �♦ //j i///� WASH RACKDRAII\1 @ J a \F l\ �' �/ / \ ' / // / ��/ r/ TO SEDIMENT TRAF / f \ - ` FFE= FFE=543.49 / I ■/ \ -►- �' / /I I ,`� \� / �'� / / , / /I CWD �\ \ \ DC \ / 530.1= - FFE=543.49 TS \ \ \ / FFE 529.62 I FFE=543.49 �' �/ FFE=543.49' 1000 0 A� _ _ - - \\ \ _ ,' /T I i �ANIT SFjwFtR / / 1 / / �, _I \ _ _ - - \' / S31, ING'AN OC - / , , I _ SE / " , , / ,// �/ //,/l / / SD CURB INLET W/GRATE ----------- ,/ /'r' /' /P E REA �- ' / I�\ u IP '/F�ANO / /' / "-� �\ `' , r�/// / ' / TOP(GRATE)=509.20' _- - - - _ - - - - / / / / L I \ \ ■ / r r / ' / -4 / r / ' 16", ' INV. OUT=506.25' 18" RCP U / W� ?` = �\ \'c� / / SSF / \," ,' / // �/ / / / SD CURB INLET W/GRATE S - - - - b ` ■ / // / / / �. , TOP GRATE-508.60' L�6ELSP'READER /' -----� ----\ \\\ ,_- `o - - _ I I \ 4't��= ` \ //r / �' \ �/r / Oc i ( ) r \ _ _ - - - \ - _ _ / - - _ / _ _ \ \ ' 1 INV. 1N=504.00' 18"RCP (NORTH) I DEPTH=0.5FT - ---- -_ �- ® � II ` - / / i i • \-' H OF LOWER SIDE r \ \ - - - - ' - '�i�r I- _ I \ I I \ \ \ r / ' // INV. 1N=504.33' 18" RCP (WEST) / \ \\-- `---__ \-------/--- -_-- UN PER R�i/ DD T N ON \ / , / / SLOPE = 6 FT - - - - - - - - - _ AP RO PE RI INAL y / / / / INV. OUT=504.02 18'RCP - - ��. I P STR G / N _ LENGTH =10FT - REAPER LIP TO BE \ r y2 - - - - 'S25-\-------- - - / SD CURB INLET W/GRATE 5 _ _ _ - -- -- --- - VEGETATED \ \ / , ' " - - - - \_ _ _ _ , _ _ _ _ \_ ; - - -` \ ------rt-------- � --�------1_-- � .( / -' \ '/ �/ � TOP (GRATE)=509.44 , _--------- -- \__---___ _-------- 8�¢LI/ - --___- DC --- -= yr ''- ' '�/ ----- \ \ / / / %, �,QC, / I // INV. OUT=506.26'18"RCP is DC _ / / SD CURB INLET W/GRATE '�M l I / \ ` ` ` ` \\ \ \\ \ \\ \ 'I'' \\�\� \/ _ SSF ♦ " - _ _ _ _ - _ _ `20 �' \ \ \ - -d - - - - - \ - _ _ ' j/ TS // / �'�OP=5f4.3 - I I / �c r' - - I �j�` ' I / 11 TOP (GRA TE)=509.06' -� _ _ INV. 1N=502.76' 18" RCP NORTH , . - - - _ _ _ „ P\I , , / , z i / o I I INV. 1N=502.95' 18" RCP (WEST) \\ \-_, \\ \ \\ \ \ \ \ \\ \`��\\` --- _ - ♦ --- _-- - --___- _ - - - 519.518 i r !75 ,S�EPP _ \ II / �// / _ ' / I INV. OUT=502.76' 18"RCP _ '516-- - i SEE SH5ET£4.2FO % / / vz. �� 515514 IP I I>0 I PROFiLF,OF§V�2 C/ IDI \---------------- EXCAVATED-6RC3WINLE�- _ - - 514- _ \ - / ` / / �C� OS - SEDIMENT TRAP #2 l515 + i , - / / 1 40 �Q \ \ \ \ ` \ ` - BOTTOM ELEVATION = 13.42 SF _ , / I O 'c \\ \ \ \ \ \ \ \ \ \ F \ \\ \ _ _ _ INLET TOP - 515.42 , I I Q5 \ RI641T�CE��S7�REA, \\\ -_-- / '.G O DRAINAGE AREA = 1`12_AC I / X�- - 7 ♦/s\ / V 'z. S [\ ` \ ` \ \ ` \ \ \ ` \ \ \ \\\ - - - REQUIRED VOLUME: - - - - - I ' II` / r /' / / / �/ \ \ \ �44i -:y 0� - - - - - - .12X AC X 134 CY X 27 CF/CY 4fl55 6F- \T1F�4�88� ` \ \ ` \ `\�` \ VULUIC><E PROVi$E[ 4165 CF - \ I I CONCRETE \ \ \ \ \ \ \ \ \ \\\ \ \ _ $OTTOM LENG - 6T8 Tjt7' A\L$EMARL l- ,SG �EiYGQR,TIRE\ \ \ \ \ \ \` \ r = _ = fl W F[3T = 9, 5' I I I FLUME `�l�EI N�TlC?I1��iF bf�UEI�TY�}QANIN�,gL� \\ - - r- \ \\ \ \ I I N6 o �lr / I / CO \ \ \ \ \ \ \ \ \ \ \ \ ` \ ` - \ I I 'r RISER (2.5 x 2 5 GRATE) 2�S \PR'44,14,, PG, 61 TOP=512.70 INV. 1N=510.40' 6" PLASTIC (SW) INV. IN=509.40' 6" PLASTIC (NE) \ _ _ 1 ) / -INV OUT=509.0115„CPP TMP 45-109C3 \ APPROX. 44' FUTURE RAW. RESERVED FOR FUTURE DEDICATION FOR PUBLIC USE UPON LARNER, JAMES & R0,K jNEII / \ I I \ DEMAND OF THE COUNTY. 0 r\ \ 7S, - \ \ ` \ \ \ \ \ \\ \\ \ r DB. 4826, PG. 608 I I / \ / / � \ ` \ 4/ \ \ ` \�\ \ \\\\ \ \ \ \ \ \`\\` ` \\ ` ` ` \ ( \ / II \ ` \ \ \ \ \ \ ` \ '�' E \ \ \ ` \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ \ \ \ \ C I P \ l / h 30 R P- - - ZONED: C-1 11 \ \ ` / / / TOP=514.14' \ \ \ \ \ \ \ ry INV. 1N=498.89 30 RCP \ o ' " EROSION & SEDIMENT CONTROL PLAN NOTES EROSION CONTROL LEGEND THIS SHEET DEPICTS PHASE 1 OF A 2 PHASE EROSION AND SEDIMENT CONTROL PLAN FOR THE SITE. THIS PHASE IS INTENDED FOR INSTALLATION OF LIMITS OF CLEARING AND GRADING PERIMETER CONTROLS. REFER TO THE EROSION AND SEDIMENT CONTROL NARRATIVE AND DETAILS (SHEETS C6.2 - C6.4) FOR ADDITIONAL INFORMATION. 1. ALL AREAS AND CURVE NUMBERS LISTED ON THIS SHEET HAVE BEEN DRAINAGE DIVIDE ROUNDED FOR SIMPLIFICATION. VESCH # VESCH # 2. ALL CONSTRUCTION TRAFFICE ACCESS IS TO BE LIMITED TO CE CONSTRUCTION ENTRANCE 3.02 TS TEMPORARY SEEDING 3.31 CONSTRUCTION ENTRANCES. 3. PERIMETER CONTROLS ARE TO BE INSTALLED AS FIRST MEASURES OF E&S SF SILT FENCE 3.05 DC DUST CONTROL 3.39 PLAN. SSF SUPER SILT FENCE 3.05 / CRITICAL SLOPES OINLET PROTECTION & IP EXCAVATED DROP INLET 3.07 CIP ® CULVERT INLET PROTECTION 3.08 s ED DIVERSION DIKE 3.12 C'M 00 Q z SCALE 1 "=30' NOR 0 30' 60' �I 0 CRAIGW 3. OTARSKI Lic. No. 0402048507 ' G .. s��OTdAL M E O p rn � N V; N p >E w E ~ LU U 3 Q �! 3 0 U. o w � y, L M Qa U 00 w = - Ln W O N v O x 0 Q w a O rn41 N N M a� 00 J CD LU �.D �___ 0 0 0 w w_ 2 U Q z 0 UO 0 am O c� z 0 H a U V) w LLJ O O O a � O O �� 0000 w O N H 0 � O DATE 04109118 DRAWN BY J. WILSON DESIGNED BY J. WILSON CHECKED BY C. KOTARSKI SCALE Q I--1 U rLU 1..� v J � Q V / I W a J z J J LU O m > Jz Q0 O W"U w J J J � Z I --I m LU J Q LU (W V / 0 cib J z Q. O rr~ ^^ V) _ 0 U w 30B NO. 40204 SHEET NO. C6.0 s c U 0 0 0 0 a a T 0 a) D 7 a) - 0 U) a co co 0 a 0 0 c as �O o O U) O 0 c E o a) c o a 0 D O (D � 3 zN O g x o m 0 a� o .3 a 0) >� Y N � �N X c: O O O U 2 N N (6 0 0 Ul U 0 E m U -O.S -0 .2 z U N 0.2 Co U - 2 cN MEn 0 0 U C CL O U� L c 0 c 0 0 T d 0 00 0 N 0 0 0 a 3 w U) Q a / 1 ) / DB. 2014, PG. 024 IP aft ft/ TREE c�ONS9 ATION AREA I— — -� l ZONED: R-6 1 _ _ / �/ / ` / / / , / 0.25 AC TOTAL p. 7s-Ac 14 SOIL TYP YA — — — _ �_ / \ HY RANT \ / / / / // 'i�i' // I __ • 5 �/ r /�/ ,/ /// /,/ //, /sue IP 1117 IPPEI /79 . / .613 1100, 1711 \ I ' ( / / / —543— 3A _ 1 \\ \' \\ \ / Q' /\/'' /// /// ///// ////' � / IP ,% f � \\� � I I I I /J� USSTO, SIGN 1,7 I _ - icn / \ , //// / 0�/• //// / h , / / , / , \L y rO55 98 (y, IP CAW) 1100, 1638 \ \ i — / / // / / / AO /CO / 1 0 v 40000L539.10 VfI�t1' / Ul Ul INJ 10 I i ---� / ` '1 -� , -_540 - ��♦�IP / ;nANTAR, R (NA-�;ERLINE 529 1 �`s�'S I // /// PS , / e _ w IP \ \ - \ / 5/ ^♦ _ _ &��.� p— /$_W _525 521 -522 523 19 \ R \�\� \\\\\ — — — — 2E _ _515, -------VdAfE L-I ��1�,/�/'/w6� / / _ .00 lie I I `-\ —_ \\\ - _ \ � \ \\ \ \\\ \\ \ \\ \ \-- - — ---- -- —\\ \\ \\\ \\\ \ \\\ \ \\ \ \\\\\\\ \\\\ \•\ \ \ \\\ \\ \\ \ \\ \\ \ \ \ \ E\��\ \ \ \ \\ \\ \\\\\� —_ er B ` - - - - - - - O/\�O/\� c'LbfCA / ' Q�INT R01T' \ \ \ - \ - -SANITARY Apk\\ \ _—_-----GRE\ _Si/SEWER ------- — — — —— / 44/ NZ 2 'IT AL$E1VIARLE OC�TY _ Nl�\ \ \PREVEN`T.IC�jNbF bWLIELT �OANI"S \ \ \ \\\ \ \ � \ � -� \ \\ - - - \ \ I I Nsso � �� �k� ' \ co \\\\ \\\\\ \ \ \ \ \ \ \ \ \ \\ \\ \ t// 1 SOIL \LV 4,04�, PQz 61 \ \ \ \ \ \\ \ \ / \ \ \ \ \ _ _ __ / 34C \\\\\Z�OwIL`QR�6 \ \\\\\ \\\ \ \ \ \\ \\� \ ll 2O6 4' \\ \ �� \ \ \ \ \ \\ \ \ \ B \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ �\ \ \ \ \ \ \ \ ) / _ \\ \ _ �� / TMP 45-109C3 \ \ / \ ' APPROX. 44' FUTURE RM.. \ \ \ \ _ \ _ \ \ \ \ \ \ \ \ as� \ \ \ \ \ \\ \\ \ \\ \ \ \ \ \ j / \ \ _ I I I/ l \ — \ \ _ \ \ \ \ \ \ \ \ \ \ s� \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ / / _ — \ \ \\ — l / EARNER, DAMES & ROX�I NE I I /\ RESERVED FOR FUTURE DEDICATION FOR PUBLIC USE UPON \\ \\ \ \ ` �\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ // I / \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ I ! / / \ \ DEMAND r THE COUNTY. \ DB. 4826, PG. 608 / \l 0 \ ZONED: C-1 I \ \ \ \\ 766 \ EROSION & SEDIMENT CONTROL NOTES THIS SHEET DEPICTS PHASE 2 OF A 2 PHASE EROSION AND SEDIMENT CONTROL PLAN FOR THE SITE. THIS PHASE IS INTENDED FOR INSTALLATION OF PERIMETER CONTROLS. REFER TO THE EROSION AND SEDIMENT CONTROL NARRATIVE AND DETAILS (SHEETS C6.2 - C6.4) FOR ADDITIONAL INFORMATION. 1. ALL CONSTRUCTION TRAFFIC ACCESS IS TO BE LIMITED TO EROSION CONTROL LEGEND VESCH # LIMITS OF CLEARING AND GRADING - DRAINAGE DIVIDE - CONSTRUCTION ENTRANCES. SOILS TYPE BOUNDARY 2. DRAINAGE DIVIDES SHOWN ARE USED FOR HYDRAULIC SF SILT FENCE ANALYSIS AND DO NOT REPRESENT AREAS OF DISTURBANCE. SSF SUPER SILT FENCE SOILS INFORMATION: IP INLET PROTECTION & SOIL MAP INFORMATION IS BASED ON DATA PROVIDED BY WEB SOIL EXCAVATED DROP INLET SURVEY (SEE SHEET C6.2 FOR ADDITIONAL INFORMATION) pS PERMANENT SEEDING CRITICAL SLOPES DRAINAGE AREA LABEL: (A] SLOPES STEEPER THAN 3:1. PLANT WITH "SLOPEMASTER MIX" B C A -AREA SIZE (AC.) B - CN BY PENNINGTON SEED. APPROXIMATE AREA OF 4640 SF. C - D.A. IDENTIFICATION 3.05 3.05 3.07 3.32 co 00 Q z SCALE 1 "=30' NOR 0 30' 60' W, i ='11 0 01 J Q CRAIGW J. K9FARSRI Lic. No. 0402048507 �ss Y101AL M E O p ul V N V; — c: > E w E ~ Lu U a 3 < LL 0 LL o i\ w O 0� yd L M QLL w U o0 W = — Lr; W p N v rj cn o x C) � a L _ N = U > Ln rn O N � M 41 a � 00 J � F- 0 0 0 w w 2 U Q z O M O DATE W"i DRAWN BY J. WILSON DESIGNED BY J. WILSON CHECKED BY C. KOTARSKI SCALE I --I I —I U w 1..� V) V 1 Lu J z 0C Q a J wQ0 i I.`L J � 1 Q�z 00 W J U � 1 mz Q W V / H� Lu 0 W V) 0 J z Q.. 0 ~ /� r v J 0 U ryoo Lu JOB NO. 40204 SHEET NO. C6.1 L- MINIMUM STANDARDS: AN EROSION AND SEDIMENT I N CONTROL PROGRAM ADOPTED BY A DISTRICT OR 0 0 LOCALITY MUST BE CONSISTENT WITH THE FOLLOWING CRITERIA, TECHNIQUES AND METHODS: MS 1. PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. MS-2. DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. MS-3. A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. MS-4. SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND -DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. MS-5. STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. MS-6. SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP OR BASIN. A. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES. B. SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY OF THE BASIN DURING A 25-YEAR STORM OF 24-HOUR DURATION. RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS UTILIZED. MS-7. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED. MS-8. CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE. MS-9. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. MS-10. ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT -LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. MS-11. BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. MS-12. WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. MS-13. WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. MS-14. ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS PERTAINING TO WORKING IN OR CROSSING LIVE WATERCOURSES SHALL BE MET. MS-15. THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED. MS-16. UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF -SITE PROPERTY. D. MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. E. RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. F. APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH. MS-17. WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND -DISTURBING ACTIVITIES. MS-18. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE LOCAL PROGRAM AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. MS-19. PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE STANDARDS AND CRITERIA LISTED IN THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK, CHAPTER 8 PAGES 20-24. PERMANENT & TEMPORARY SEEDING AND STABILIZATION: THE ESTABLISHMENT OF A TEMPORARY VEGETATIVE COVER ON DISTURBED AREAS BY SEEDING WITH APPROPRIATE RAPIDLY GROWING ANNUAL PLANTS; EMPLOYED TO REDUCE EROSION AND SEDIMENTATION BY STABILIZING DISTURBED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE FOR A PERIOD OF MORE THAN 14 DAYS, TO REDUCE DAMAGE FROM SEDIMENT AND RUNOFF TO DOWNSTREAM OR OFF SITE AREAS, AND TO PROVIDE PROTECTION TO BARE SOILS EXPOSED DURING CONSTRUCTION UNTIL PERMANENT VEGETATION OR OTHER EROSION CONTROL MEASURES CAN BE ESTABLISHED. WHERE EXPOSED SOIL SURFACES ARE NOT TO BE FINE -GRADED FOR PERIODS LONGER THAN 30 DAYS. SUCH AREAS INCLUDE DENUDED AREAS, SOIL STOCKPILES, DIKES, DAMS, SIDES OF SEDIMENT BASINS, TEMPORARY ROADBANKS, ETC. (SEE MS #1 AND MS #2 ON THIS SHEET). A PERMANENT VEGETATIVE COVER SHALL BE APPLIED TO AREAS THAT WILL BE LEFT DORMANT FOR A PERIOD OF MORE THAN 1 YEAR. 1. SELECTION OF PLANT MATERIAL IS BASED ON SPECIFIC SITE AND PLANTING SEASON. A SITE SPECIFIC MIX DETERMINED USING TABLES 3.31B OF THE VESCH, SEE TABLE ON THIS SHEET. 2. ALL PERMANENT SEEDING SHALL BE PLACED PER THE VESCH 3.32, SEE TABLE ON THIS SHEET. 3. ALL TEMPORARY SEEDING, FERTILIZER, AND MULCH SHALL BE PLACED PER THE VESCH 3.31. DUST CONTROL PREVENT SURFACE AND AIR MOVEMENT OF DUST FROM EXPOSED SOIL SURFACES AND REDUCE THE PRESENCE OF AIRBORNE SUBSTANCES WHICH MAY PRESENT HEALTH HAZARD, TRAFFIC SAFETY PROBLEMS OR HARM ANIMAL OR PLANT LIFE BY USING ONE OR A COMBINATION OF THE FOLLOWING METHODS IN ACCORDANCE TO SECTION 3.39 OF THE VESCH: VEGETATIVE COVER, MULCH, TILLAGE, IRRIGATION, SPRAY -ON ADHESIVES, STONE, BARRIERS, CALCIUM CHLORIDE, AND PERMANENT VEGETATION. STOCKPILE THE GRADING/EXCAVATION CONTRACTOR FOR THE SUBJECT SITE IS REQUIRED TO NOTIFY IN WRITING, THE ASSIGNED SITE INSPECTOR REGARDING ANY EXCESS MATERIAL PROPOSED TO BE HAULED OFFSITE PRIOR TO HAULING. THE NOTIFICATION MUST INDICATE THE QUANTITY OF MATERIAL TO BE MOVED OFFSITE, THE IDENTIFICATION OF THE RECEIVING SITE WHERE THE EXCESS WILL BE TAKEN, AND ALL INFORMATION NECESSARY TO SHOW THAT SUCH RECEIVING SITE HAS BEEN PROPERLY PERMITTED AND EROSION AND SEDIMENT CONTROLS INSTALLED. GENERAL CONSTRUCTION NOTES FOR EROSION AND SEDIMENT CONTROL 1. THE PLAN APPROVING AUTHORITY MUST BE NOTIFIED ONE WEEK PRIOR 18 TO THE PRE -CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO THE FINAL INSPECTION. 2. ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS. 3. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED 19 PRIOR TO OR AS THE FIRST STEP IN CLEARING. 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFF -SITE BORROW OR WASTE AREAS), THE CONTRACTOR SHALL SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND APPROVAL BY THE PLAN APPROVING AUTHORITY. 2 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE PLAN APPROVING AUTHORITY. 21 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 2 8. DURING DEWATERING OPERATIONS, WATER WILL BE PUMPED INTO AN APPROVED FILTERING DEVICE. 9. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 10. ALL FILL MATERIAL TO BE TAKEN FROM AN APPROVED, DESIGNATED BORROW AREA. 11. ALL WASTE MATERIALS SHALL BE TAKEN TO AN APPROVED WASTE AREA. EARTH FILL SHALL BE INERT MATERIALS ONLY, FREE OF ROOTS, STUMPS, WOOD, RUBBISH, AND OTHER DEBRIS. 12. BORROW OR WASTE AREAS ARE TO BE RECLAIMED WITHIN 7 DAYS OF COMPLETION PER ZONING ORDINANCE SECTION 5.1.28. 13. ALL INERT MATERIALS SHALL BE TRANSPORTED IN COMPLIANCE WITH SECTION 13-301 OF THE CODE OF ALBEMARLE. 14. BORROW, FILL OR WASTE ACTIVITY INVOLVING INDUSTRIAL -TYPE POWER EQUIPMENT SHALL BE LIMITED TO THE HOURS OF 7:OOAM TO 9:OOPM. 15. BORROW, FILL OR WASTE ACTIVITY SHALL BE CONDUCTED IN A SAFE MANNER THAT MAINTAINS LATERAL SUPPORT, OR ORDER TO MINIMIZE ANY HAZARD TO PERSONS, PHYSICAL DAMAGE TO ADJACENT LAND AND STRUCTURES/IMPROVEMENTS, AND DAMAGE TO ANY PUBLIC STREET BECAUSE OF SLIDES, SINKING, OR COLLAPSE. 16. THE DEVELOPER SHALL RESERVE THE RIGHT TO INSTALL, MAINTAIN, REMOVE OR CONVERT TO PERMANENT STORMWATER MANAGEMENT FACILITIES WHERE APPLICABLE ALL EROSION CONTROL MEASURES REQUIRED BY THIS PLAN REGARDLESS OF THE SALE OF ANY LOT, UNIT, BUILDING OR OTHER PORTION OF THE PROPERTY. 17. TEMPORARY STABILIZATION SHALL BE TEMPORARY SEEDING AND MULCHING. SEEDING IS TO BE AT 75 LBS/ACRE, AND IN THE MONTHS OF SEPTEMBER TO FEBRUARY TO CONSIST A 50/50 MIX OF ANNUAL RYEGRASS AND CEREAL WINTER RYE, OR IN MARCH AND APRIL TO 3T b, 721230 721M 7213m 721380 � 5�N 9 Custom Snip Resource Report Soil Map 721430 721�] 721537 721584 CONSIST OF ANNUAL RYE, OR MAY THROUGH AUGUST TO CONSIST OF 0. 2. EROSION AND SEDIMENT CONTROL NARRATIVE GERMAN MILLET. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION PROJECT DESCRIPTIONPE INSPECTOR. CONTROL IN R. THIS PROJECT INVOLVES THE CONSTRUCTION OF SEVERAL BUILDING PERMANENT STABILIZATION SHALL BE LIME AND FERTILIZER, PERMANENT ADDITIONS AND TWO PARKING LOTS AND ASSOCIATED SITE WORK. LIMITS OF SEEDING, AND MULCH. AGRICULTURAL GRADE LIMESTONE SHALL BE CLEARING AND GRADING ARE 2.50 ACRES. APPLIED AT 90LBS/1000SF, INCORPORATED INTO THE TOP 4-6 INCHES OF SOIL. FERTILIZER SHALL BE APPLIED AT 1000LBS/ACRE AND CONSIST OF SCHEDULE: THE PROJECT IS ANTICIPATED TO BEGIN CONSTRUCTION IN LATE A 10-20-10 NUTRIENT MIX. PERMANENT SEEDING SHALL BE APPLIED AT 2018 AND BE COMPLETED PRIOR TO Q4 OF 2019. 180LBS/ACRE AND CONSIST OF 95% KENTUCKY 31 OR TALL FESCUE AND 0-5% PERENNIAL RYEGRASS OR KENTUCKY BLUEGRASS. STRAW MULCH IS ADJACENT PROPERTY TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO THE PROPERTY IS BOUNDED BY BUISNESS TO THE SOUTH, RESIDENTIAL AREAS APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. TO THE WEST,BERKMAR DR TO THE EAST, AND AN INDUSTRIAL AREA TO THE MAINTENANCE: ALL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER NORTH. EACH RAINFALL EVENT. ANY DAMAGE OR CLOGGING TO STRUCTURAL MEASURES SHALL BE REPAIRED IMMEDIATELY. SILT TRAPS SHALL BE EXISTING SITE CONDITIONS CLEANED WHEN 50% OF THE WET STORAGE VOLUME IS FILLED WITH THE SITE IS CURRENTLY THE CHARLOTTESVILLE ALBEMARLE SPCA SEDIMENT. ALL SEEDED AREAS SHALL BE RESEEDED WHEN NECESSARY TO ACHIEVE A GOOD STAND OF GRASS. SILT FENCE AND DIVERSION OFF -SITE AREAS DYKES WHICH COLLECT SEDIMENT TO HALF THEIR HEIGHT MUST BE NO OFF -SITE AREAS WILL BE DISTURBED AS A PART OF THIS PROJECT. CLEANED AND REPAIRED IMMEDIATELY. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CRITICAL EROSION AREAS REMOVED WITHIN 30 DAYS OF FINAL SITE STABILIZATION, WHEN EX BIORETENTION FILTER/EX DETENTION PIPES: THERE IS AN EXISTING BIORETENTION MEASURES ARE NO LONGER NEEDED, SUBJECT TO APPROVAL BY THE FILTER AND UNDERGROUND DETENTION SYSTEM IN OR NEAR THE LIMITS OF WORK. COUNTY EROSION CONTROL INSPECTOR. CARE SHOULD BE TAKEN TO AVOID SEDIMENT FROM ENTERING EITHER FACILITY. THIS PLAN SHALL BE VOID IF THE OWNER DOES NOT OBTAIN A PERMIT WTIHIN 1 YEAR OF THE DATE OF APPROVAL. (WATER PROTECTION EX INTERMITTENT STREAM: LOCATED ON THE WESTERN END OF THE PROPERTY, ORDINANCE SECTION 17-204G.) OUTSIDE THE LIMITS OF DISTURBANCE. CARE SHOULD BE TAKEN TO AVOID SEDIMENT PERMANENT VEGETATION SHALL BE INSTALLED ON ALL DENUDED AREAS ENTERING THE STREAM. ADDITIONALLY NO WORK IS PROPOSED OR ALLOW NEAR THE WITHIN NINE (9) MONTHS AFTER THE DATE THE LAND DISTURBING STREAM WITH THIS PLAN. ACTIVITY COMMENCED. (WATER PROTECTION ORDINANCE SECTION 17-207B) EROSION AND SEDIMENT CONTROL MEASURES 721630 721GBO 7212,Y 7212W 7213X 721 4 7Za:1n 7ZW4 Q i21$3v 7"x1 721630 721tw 721m �:7 r Map Scale, 1:2,490 W pitEd on A landsmpe (117 x S. 5") Meet � f N o ss 70 1aa1 O Map prgecbw Web Merminr Comer o"dnates: VVCS84 Edge tcs; UM Zane 17N WGS84 9 UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE CURRENT ADDITION OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. THE MINIMUM STANDARDS OF THE VESCH SHALL BE ADHERED TO UNLESS OTHERWISE WAIVED OR APPROVED BY A VARIANCE BY LOCAL AUTHORITIES HAVING JURISDICTION. STORMWATER RUNOFF CONSIDERATIONS STORMWATER QUALITY REQUIREMENTS ARE BEING SATISFIED THROUGH THE USE OF NUTRIENT CREDITS AND STORMCEPTORS. EROSION AND SEDIMENT CONTROL MEASURES MAINTENANCE ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED IN ACCORDANCE WITH VESCH AND THE CONSTRUCTION SEQUENCE, INCLUDING THE INSPECTION OF ALL MEASURES AFTER ALL RAIN EVENTS. SEQUENCE OF INSTALLATION PHASE I (SEE SHEET C6.0) 1. A PRE -CONSTRUCTION MEETING IS REQUIRED WITH THE COUNTY OF ALBEMARLE, CONTRACTOR, OWNER, AND ENGINEER. THIS MEETING SHALL TAKE PLACE AT ALBEMARLE COUNTY COMMUNITY DEVELOPMENT. 2. INSTALL ALL EROSION AND SEDIMENT CONTROL MEASURES SHOWN ON THE PHASE I PLAN, PERIMETER CONTROLS AND THE CONSTRUCTION ENTRANCE. ONCE PERIMETER CONTROLS ARE INSTALLED. INSTALL STORM SEWER SYSTEM, AND EXCAVATED DROP INLET SEDIMENT TRAPS AS SHOWN ON THE PHASE I PLANS. 3. AFTER ALL EROSION AND SEDIMENT CONTROL PHASE I MEASURES ARE IN PLACE AND APPROVED BY THE E&S INSPECTOR, SITE WORK CAN BEGIN. 4. ROUGH GRADE PROJECT AREA. 5. SEED ALL DENUDED AREAS PER VESCH STANDARDS. PHASE II (SEE SHEET C6.1) 1. INSTALL ADDITIONAL INLET PROTECTION WHERE SHOWN ON THE PHASE II EROSION AND SEDIMENT CONTROL PLAN AS THE STORM SYSTEM IS CONSTRUCTED AND BECOMES OPERATIONAL. 2. FINE GRADE PROJECT AREA. APPLY PERMANENT SOIL STABILIZATION TO THESE AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS ACHIEVED. REFER TO MS-1 FOR TEMPORARY STABILIZATION REQUIREMENTS. 3. ALL STORMWATER PIPING & STRUCTURES SHALL BE INSPECTED FOR 38_ 5 38'N SILT/SEDIMENT. IF PRESENT, SILT/SEDIMENT SHALL BE CLEANED OUT FOR THE SYSTEM TO THE SATISFACTION OF THE E&S INSPECTOR. 4. APPLY PERMANENT SOIL STABILIZATION TO THESE AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS ACHIEVED. SILT FENCE, CULVERT INLET �! PROTECTION AND INLET PROTECTION MUST BE MAINTAINED THROUGH ' GRADING AND CONSTRUCTION. 5. ONCE CONSTRUCTION IS COMPLETE AND ALL CONTRIBUTING AREAS ARE STABILIZED, EROSION CONTROL MEASURES CAN BE REMOVED UPON APPROVAL FROM THE E&S INSPECTOR. STRUCTURAL PRACTICES: 1. TEMPORARY CONSTRUCTION ENTRANCE WITH PAVED WASH RACK - 3.02 A TEMPORARY CONSTRUCTION ENTRANCE AND PAVED WASH RACK SHALL BE PROVIDED AT THE LOCATION INDICATED ON THE PLANS. IT IS IMPERATIVE THAT THIS MEASURE BE MAINTAINED THROUGHOUT CONSTRUCTION. ITS PURPOSE IS TO REDUCE THE AMOUNT OF MUD TRANSPORTED ONTO PAVED ROADS BY MOTOR VEHICLES OR RUNOFF. 2. SILT FENCE BARRIER - 3.05 SILT FENCE SEDIMENT BARRIERS SHALL BE INSTALLED DOWNSLOPE OF AREAS WITH MINIMAL GRADES TO FILTER SEDIMENT -LADEN RUNOFF FROM SHEET FLOW AS INDICATED. ITS PURPOSE IS TO INTERCEPT SMALL AMOUNTS OF SEDIMENT FROM DISTURBED AREAS AND PREVENT SEDIMENT FROM LEAVING THE SITE. 3. STORM DRAIN INLET PROTECTION - 3.07 STONE FILTERS SHALL BE PLACED AT THE INLET OF ALL DRAINAGE STRUCTURES AS INDICATED ON PLANS. ITS PURPOSE IS TO PREVENT SEDIMENT FROM ENTERING THE STORM DRAINS. 4. DIVERSION DIKE - 3.09 A TEMPORARY RIDGE OF COMPACTED SOIL TO DIVERT WATER FROM A CERTAIN AREA. Q 5. DUST CONTROL - 3.39 DUST CONTROL IS TO BE USED THROUGH THE SITE IN AREAS SUBJECT TO SURFACE AND AIR MOVEMENT. VEGETATIVE PRACTICES: 1. TOPSOIL (TEMPORARY STOCKPILE) - 3.30 TOPSOIL SHALL BE STRIPPED FROM AREAS TO BE GRADED AND STOCKPILED FOR LATER SPREADING. 4 STOCKPILE LOCATIONS SHALL BE LOCATED ONSITE AND SHALL BE STABILIZED WITH TEMPORARY SILT FENCE AND VEGETATION. 2. TEMPORARY SEEDING - 3.31 ALL DENUDED AREAS WHICH WILL BE LEFT DORMANT FOR MORE THAN 30 DAYS SHALL BE SEEDED WITH FAST GERMINATING TEMPORARY VEGETATION IMMEDIATELY FOLLOWING GRADING OF THOSE AREAS. SELECTION OF THE SEED MIXTURE SHALL DEPEND ON THE TIME OF YEAR IT IS APPLIED. �" �• 3. PERMANENT SEEDING - 3.32 FOLLOWING GRADING ACTIVITIES, ESTABLISH PERENNIAL VEGETATIVE COVER BY PLANTING SEED OR SOD TO REDUCE EROSION, STABILIZE DISTURBED AREAS, AND ENHANCE NATURAL BEAUTY. 4. SOIL STABILIZATION BLANKETS & MATTING - 3.36 A PROTECTIVE COVERING BLANKET OR SOIL STABILIZATION MAT SHALL BE INSTALLED ON PREPARED PLANTING AREAS OF CHANNELS TO PROTECT AND PROMOTE VEGETATION ESTABLISHMENT AND REINFORCE ESTABLISHED TURF. MANAGEMENT STRATEGIES 1. ESTABLISH PERIMTER CONTROLS AND CONSTRUCTION ENTRANCE. 2. PROVIDE SEDIMENT TRAPPING MEASURES AS A FIRST STEP IN GRADING, SEED AND MULCH IMMEDIATELY FOLLOWING INSTALLATION. 3. PROVIDE TEMPORARY SEEDING OR OTHER STABILIZATION IMMEDIATELY AFTER GRADING. 4. ISOLATE TRENCHING FOR UTILITIES AND DRAINAGE FROM DOWNSTREAM CONVEYANCES IN ORDER TO MINIMIZE PERIMETER CONTROLS. 5. ALL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE MAINTAINED UNTIL THEY ARE NO LONGER REQUIRED TO COMPLY WITH THE CONTRACT DOCUMENTS OR STATE LAW. PERMANENT STABILIZATION ALL NON -PAVED AREAS DISTURBED BY CONSTRUCTION SHALL BE STABILIZED WITH PERMANENT SEEDING OR SOD IMMEDIATELY FOLLOWING FINISHED GRADING. SEEDING SHALL BE IN ACCORDANCE WITH STD. & SPEC. 3.32, PERMANENT SEEDING. SEED TYPE SHALL BE AS SPECIFIED FOR "MINIMUM CARE LAWNS" AND "GENERAL SLOPES" IN THE HANDBOOK FOR SLOPES LESS THAN 3:1. FOR SLOPES GREATER THAN 3:1, SEED TYPE SHALL BE AS SPECIFIED FOR "LOW MAINTENANCE SLOPES" IN TABLE 3.32-D OF THE HANDBOOK. FOR MULCH (STRAW OR FIBER) SHALL BE USED ON ALL SEEDED SURFACES. IN ALL SEEDING OPERATIONS SEED, FERTILIZER AND LIME SHALL BE APPLIED PRIOR TO MULCHING. SAFE WORK ENVIRONMENT y vd` �pJ7� 1\ r Q CRAIGW I. KOTA-RSKI Lic. No. 0402048507 CONTRACTOR SHALL PROVIDE A SAFE WORK ENVIRONMENT AT ALL TIMES. THE o 0 LIMITS OF WORK ARE LOCATED WITHIN AN ACTIVE ANIMAL SHELTER. CARE N SHOULD BE GIVEN TO MONITORING SAFE PERIMETER CONDITIONS AND LIMITIN Q o ACCESS INTO WORK AREAS. MAINTENANCE OF TRAFFIC, INCLUDING > E q' CONSTRUCTION TRAFFIC, SHALL BE COORDINATED WITH THE OWNER TO LU PREVENT CONFLICTS WITH PASSENGER VEHICLES, PUBLIC TRANSPORTATION, F- � PEDESTRIAN TRAFFIC, AND BICYCLE TRAFFIC. Q L o 0 w 11� yd L M Qo_ U 00 W = - Lr; a p N z� a'C1321 O x af � oQ � _ N U ko = > Ln a - Ln O rn 41 N 00 J O a U V) w 0 z O LU W W 0 0 W W a a O O j � � DATE W"i DRAWN BY J. WILSON DESIGNED BY J. WILSON CHECKED BY C. KOTARSKI SCALE U m LU V / LU ~ J Q z J LU 0 W > J�z Q z 0 �U 0 W LU w JJz J < w w H m H� > Q 0 V / rw^ V LU oZ5 z 0 0 J ./ O C). Q w 1 U JOB NO. 40204 SHEET NO. C6.2 U 0 0 0 a Q T `o 0 a� 0 a c co co a 0 0 as �0 o U �U) �z 0 0 c E o �0 0-e 0 � 3 zN 0 � a g x w� o m 0 a� o .3 a 0) ID � Y �N X C: a) 0 O U 2 N u, (6 0 N o �o E U N -0 20 w-0 .Co U o N o N •- Co U -0 2 CN MEn U) 0 U a O..- a)_0 U� L 1992 3.21 LEVEL SPREADER CROSS SECTION JUTE, OR EXCELSIOR OR EQUIVALENT STAPLED IN PLACE VARIABLE (MIN. 7') BURIED 6" MIN. 6" MIN. RIED 6" MIN. �fAua�rA M6n.... BU �r LEVEL LIP OF I I=111� 11=1 I I �I I I=11 �I 1=III=III—I I I=1t l — — I III —III III —I I � T I —I 11=1 2:1 OR SPREADER II II TI I — — — — — — FLATTER MIN• 6' LEVEL SPREADER WITH VEGETATED LIP CROSS SECTION VDOT #3, #357, #5, #56 OR #57 COARSE AGGREGATE IN VARIABLE (MIN. 7') GALVANIZED WIRE MESH BASKET SECURE WIRE MESH TO TIMBER » FILTER CLOTH 6X6 TREATED TIMBER SECURE WIRE TO GROUND MIN• WITH WIRE STAPLES #5 REBAR TO aeY T MIN. I 3' =1 I �I I I —I I t=1 I �I I I —I I I� 11=1I 1=1 I I —III— I I—III—III—IIIX UNDISTURBED === I I 1 11=111=111=SOIL —T�I 1=1 1=1 1�1=�1=1 1 M 1�-- 11FL' T R — FLATTER k4k 6, LEVEL SPREADER WITH RIGID LIP * MIN. PHYSICAL REQUIREMENTS OF FILTER CLOTH NOTED IN STD. & SPEC. 3.19, RIPRAP Source: Va. DSWC and N.C. Erosion and Sediment Control Planning and Design Manual Plate 3.21-2 III - 195 1992 LEVEL SPREADER LAST 20' OF DIVERSION NOT TO EXCEED 1% GRADE 3.21 DIVERSION .....::.:..: .. ::'l S L R.... .......... LIZ ............... ............ ........ED ........SRO P E:. ..:...:::........:............... ................. .... ::::..... ::: ::.:.::::: • ..... . er.:........................................................ .................. UN'DIS"rUiiB.R...O(4TtEl ::......'............` ... ........ ......... .....................:.... .... . .......... .:..:........:................. :.: '::::::: ::::: :::: ..... `::.. ..:........ .............. ...... .... ......... ......:...... ... ............. . ................. ........ ........................... .................. SX6 ;SACT::...... ....::::............::: ............................................... ....................................... ..... ................ .:........ .............................................:::::::::.............. ................ ..............:::.............. . TIMBER::::.. •..::::::::........'.::::::::::::......:::::::::::::::::......... ............................. PERSPECTIVE VIEW NOTE: ALL TEMPORARY BERMS, SWALES AND LEVEL SPREADER DITCH MUST RECEIVE TEMPORARY SEEDING IMMEDIATELY AFTER INSTALLATION Source: Adapted from N.C. Erosion and Sediment Control Planning and Design Manual III - 193 Plate 3.21-1 /=/mff//A—/ Mat\ U(( / l 0 / l 1/0 ENDWALL L TOE OF FILL 0 0 o 0 SILT FENCE o 0 * DISTANCE IS 6' MINIMUM IF FLOW IS TOWARD EMBANKMENT FLOW OPTIONAL STONE COMBINA TION 1.0' 1.5' FLOW *VDOT #3, #357, #5, #56 OR #57 UUAKSL AUUNLUAIL TO REPLACE SILT FENCE IN " HORSESHOE WHEN HIGH VELOCITY OF FLOW IS EXPECTED SOURCE: ADAPTED from VDOT Standard Sheets and Va. DSWC 2.5' CLASS I RIPRAP PLATE. 3.08-1 1.5 SIL T FENCE DR OP INLE T PR 0 TE C TION 2 X 4' WOOD FRAME STAKE DROP INLET •r„ rnnrr PERSPECTIVE VIEWS ELEVATION OF STAKE AND FABRIC ORIENTATION SPECIFIC APPLICATION 4ME THEIR CESS H� CORNERS DETAIL A THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE THE INLET DRAINS A RELATIVELY FLAT AREA (SLOPE NO GREATER THAN 5%) WHERE THE INLET SHEET OR OVERLAND FLOWS (NOT EXCEEDING 1 C.F.S.) ARE TYPICAL. THE METHOD SHALL NOT APPLY TO INLETS RECEIVING CONCENTRATED FLOWS, SUCH AS IN STREET OR HIGHWAY MEDIANS. SOURCE: N.C. Erosion and Sediment Control Planning and Design Manual, 1988 10% SETTLEMENT n q' DDP.P, 1:)/IADTI--*1\ Y TYPICAL PARABOLIC DIVERSION 10% SETTLEMENT TYPICAL TRAPEZOIDAL DIVERSION 10% SETTLEMENT Source: Va. DSWC TYPICAL VEE - SHAPED DIVERSION PLATE 3.07-1 Plate 3.12-1 S•.J E OP.ydeca�sgi� "S fW� Q CRAYG W I. IOTA-RS ICI L1G. No, 0402048507 10/12/18 ,c,J M E O O M U N L� N O Q O > E w °� E W U o � Q LL o w O o cl� L M LU U � d J J — W Lr; a > C � N ('D W Q O Q w o Q D 11:3. _ N U Ln 2 QLn C� O N a L M d V 00 J O w z O d U U w z O > w cW W G C) C) U U Q-a OO � LL1 W ck� Q� DATE DRAWN BY J. WILSON DESIGNED BY J. WILSON CHECKED BY C. KOTARSKI SCALE Q U V / (n J W ~ J a oC LU Q � C J G O LU co } J O Q ~ U z O wwz J J w J Q � H H� LU 0 > J W V / C6 LU z O I --I O V) J C) W i U JOB NO. 40204 SHEET NO. C6.3 Wa S O a� o O �z �O o 2i � o �0 a o c 0� 2 O r ' z N O a) 2 Q X x o w � o Qw o '3 0-0) > � m �N X O a> .o O U :5 2 0 0 6 0 O N U O O o E 7 O U @ O0 6 � .20 .m U o N _o @ U a 2 �N U� N o C:U Mo Qw oD W(D L NOTES: 1. THE EROSION AND SEDIMENT CONTROL DETAILS SHOWN WITHIN THIS PLAN SET ARE INTENDED TO PROVIDE A REFERENCE TO THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH). THE GRAPHIC DETAILS PROVIDED HAVE BEEN EXTRACTED FROM THE VESCH. CONTRACTOR SHOULD VERIFY FAMILIARITY WITH THE VESCH AND THE TEXT ASSOCIATED WITH THE REFERENCED DETAILS. 2. REFER TO EROSION AND SEDIMENT CONTROL NARRATIVE FOR ADDITIONAL INFORMATION. 3. INLET PROTECTION IS TO BE PROVIDED IN ORDER TO ENSURE THAT FLOW WILL ENTER THE INLET DURING ROAD/PARKING PAVING AND WHEN GUTTER PAN ELEVATION IS HIGHER THAN THE TEMPORARY ROAD/PARKING SURFACE. EXISTING GROUND 70' MIN. FILTER CLOTH 6" MIN. I Al e-11-1r rl r\ / A T1 ^ \ 1 70' MIN. B WASHRACK I (❑PTI❑NAL) Z— VD❑T #1 P❑SITIVE DRAINAGE COURSE AGGREGATE B TO SEDIMENT TRAPPING DEVICE * MUST EXTEND FULL WIDTH PLAN VIEW OF INGRESS AND EGRESS OPERATION RE11Vr L mur-lI L.LJIVL.KL I t SECTION A -A SECTION B-B EXISTING PAVEMENT 5:1 y SOURCE: ADAPTED from 1983 Maryland Standards for Soil erosion and Sediment Control, and Va. DSWC w MOUNTABLE BERM (❑PTI❑NAL) 10' MIN. EXISTING PAVEMENT 10' MIN. BLOCK k GRAVEL CURB INLET ,S°E1'IMENT FIL TER RUNOFF OVERFLOW WATT A/ITI SI VI\(IV LL I ILI LI\ P-II TFPm \A/OTF-R 2" X 4" WOOD STUD CURB INLET SPECIAL APPLICATION THIS METHOD OF INLET PROTECTION IS APPLICABLE AT CURB INLETS WHERE AN OVERFLOW CAPABILITY IS NECESSARY TO PREVENT EXCESSIVE PONDING IN FRONT OF THE STRUCTURE. * GRAVEL SHALL BE VDOT #3, #357 OR #5 COARSE AGGREGATE CONSTRUCTION OF A SILT FENCE (WITHOUT WIPE SUPPORT) 1. SET THE STAKES. 2. EXCAVATE A 4"X 4" TRENCH UPSLOPE ALONG THE LINE OF STAKES. 6' MAX. -/ 1- FLOW � 3. STAPLE FILTER MATERIAL TO STAKES AND EXTEND IT INTO THE TRENCH. r G 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. G FLOW —Iliiill�ll� — Ii SHEET FLOW INSTALLATION (PERSPECTIVE VIEW) F 1 POINTS A SHOULD BE HIGHER THAN POINT B. DRAINAGEWAY INSTALLATION (FRONT ELEVATION) Plate 3.02-1 SOURCE: Adapted from Installation of Straw and Fabric Filter Barriers for Sediment Control,VA. DSWC PLATE. 3.05-2 Sherwood and Wyant CONSTRUCTION OF A SILT FENCE (WITH WIRE S UPPOR T) 1. SET POSTS AND EXCAVATE A 4"X4" 2. STAPLE WIRE FENCING TO THE POSTS. TRENCH UPSLOPE ALONG THE LINE OF POSTS. /I FLOW 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH. FLOW 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. I EXTENSION OF FABRIC AND WIRE INTO THE TRENCH. FILTER FABRIC / \ y /� r� Lic. No, 0402-048507 10/12/18 2"'1 Y M !_ 0 0 M U N In N C > !_ wLu ~ (! < U. 0 w O o d' lJJ L M Qa � U o� C" > o r C7 Lu z �- cu 0 O x <0 OQ �� \n _ N = U > Ln Q . c Ln O N a L M a � CO J z O d U Ln w z O_ W W W 0 0 U U Q- CL oa Lu Lu j Lu O N Q 0 o O DATE 04109118 DRAWN BY 1. WILSON DESIGNED BY 1. WILSON CHECKED BY C. KOTARSKI SCALE Q U II.—, w Q J w C J G 0 Lu m>z �0 J ~ U Qz O wwz J J w J Q Lu � H I —I m p >>J w Q V / 06 Lu z 0 I --I 0 J 0 w Q i U JOB NO. 40204 SHEET NO. C6.4 L- SOURCE: Adapted from Installation of Straw and Fabric Filter Barriers for Sediment Control, SOURCE: VA. DSWC PLATE 3.07-8 Sherwood & Wyant PLATE. 3.05-1 Section 5. Stormwater Management Plan (Provide a reduced 11x17 copy of the latest stormwater management plan. Do not reference only.) Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County 1 530 1 525 1 520 1 515 1510 1 505 1500 1495 1490 FFE=543.47' FFE=543.42' 2 STORY FFE=543.49' BLOCK & HARDI-PLANK BUILDING (CASPCA FACILITY) 3355 BERKMAR DRIVE I CONC. PAD CONC. PAD (12.7'x3.7) (1Tx8) I W/GENERATOR W/A1R 2� U CONC. PAD FFE= TRANSFER (6.8"x 7.8) Wr 530.12' FFE=529.62' TRANSFORMER x `♦ ® o ■ 20' ACSA ROCK \ INV. IN=511.67 15 RCP R D 'It \ , / _ \ ` ARMOR \ / / _ _ _-�- INV. OUT=511.42' 15" RCP // 0 CUR B INL ET I �I MHDRD WOOD P_5435'�- FOOT-BRIDG WDR4NT INVOUT=510�5'15"R ­1. y CRAIG'VI? J. K(YFA zSK FFE-543.47 1638 \ /.' „s% / J--- 10 -- , \ Lip. I'es. 0�i02048507 I WLAB TE 4 0 10/12/18 SD CYRB INLET W/GRA ' / TOP GRATE -513. 8 ��� �j REPLACE WITH MH TOP \ 5n� i \ �,( ( )- -�(;NAL y I 16 9 L 1 CLO ADJUST TO MATCH � xA ♦ I I , / 1N=510.30 15 RCP (NORTH 539.10 / 0,, ' y1 / 1N=510.43 5 RCP (WEST) • � PROP GRADE v� ------ FFE=543.49 I L 1 164 4 , f 1 B I I\/ V. OUT=510. 5' 15" RCP FFE=543.49' VWL / ; ' / \,;��' ♦ % I I / o E / / II/ BUS STO�SIGN N o FFE=543.49 -SAN / ;' %I J CCiLj V) M R5 I F/� Q o FFE-543.49 _C Nc ■ / / ♦ ' / Cig4 > E 1 9� 1�R/SE S I \ 7 \ STEP R5 /XI FNTR'9NC w 1 R 'g' f I R5\ 1 C a 00 a / ♦ D C N /M a w SANI R SE R T =525.5 1C1 / / II / w / 5.IIII I R SERVI U ER TED 5EASEMENT V1N=5 / \C, LFIELD LO twNVO9.02' P=510.72' O■CLEAN-O 5' 4" DIP z II /QQ i 2 ° I I � s9 O � � / / Py � %' / ♦ ,'���\\ \ IV. NV. 1N=507.56' 18"RCP (EAST) � W o � / IN1N=507.30 18'RCP (WEST) � a� M WATERLINE Q� ; / / ( z - e INV. OUT=506.62 18 RCP G _-•-____ ___________ ------a-- • - ea e ' d a a e (28 T 44' � � Lu ------ 4" , 8 C C� 8" DIP WATERLINE R4.5" 8"W �- APPROX. LOCATION OF INTERMITTENT STREAM TMP 45-88 THE ALBEMARLE SOCIETY FOR THE PREVENTION OF CRUELTY TO ANIMALS DB. 4444, PG. 616 ZONED: R-6 REZONING: C-1 R4.5' Jv ��� • d II ♦ / /� �R3' / /� / SD CURB INLET W/GRATE o J ,-- , j / // TOP (GRA TE)-510.39' _ ¢ , r, � GRouN 42 ♦ �- . dS X PER L ,F, R 'D' ; ; / / QSQ' / / ♦ / / / �// INV. OUT=507.89' 18" RCPEA Lu ~ o ----�__ _-- STRUCTURE ' % ° / / L M c ___---------------------- - - ' / / // SD CURB INLET W/GRAT 0- w w ---------------- NOT FOUND/ i / / ° ' ♦ / // / // o w ----------- - --L_ I _ i \ - I I � � TOP (GRATE)=511.34 � � --------------- ------ -- - ----- -� $ W / / // INV. 1N=508.81' 15"RCP ( O O - _ _ aZ _ • 1 C2 / �/ / IINV. OUT=508.41 ' 18" RC U U 8"W 8 W �\�` (210, 21S' '� 1638 ° ° R5' ♦ / /� / /// � a a W _R I---��',10 `LR3 o O a WATER METER T ? I �1d�`1,B / _ - ,1641 R5 // (D >> G l =51 PP 6 I 16 9 L1 CLO METAL FENCE 8• DIP + �G� 2C 539. `1 �___-_ 164 R5 1 D / o co co Lu 8" PVC S WATERLINE\� b" p�G vWL 4 > w 2B / w ~ .o II I ON I R5' RS / / / // = Q N 111 i -SAN // / /// Q O o 0 2 D B S C NC1 C3 3' /// /� o PROPOSED PRIVATE 8„pVC mu:II 1 ��' 11 R1SEfs'I\ \ Rq SER T CE R O R // / / %/ ? DATE SANITARY SEWER _ - -- X� • II R I R5\ C1viL TE AN11v 04109118 11 CO O SANI R SE R II 2A k II SERVI E // SD CURB INLET W/GRATE DRAWN BY CONCRETE II ■ ED FIELD-LO \ / / / 8 // TOPRA920' 1. WILSON FLUME 11 II I R CLEAN-OU S 7 INV OU506.25, N � s 6 2"3� �cjO Q. I `f'9� DESIGNED BY RISER (2.5 x 2.5'GRA TE) TOP=512.70' 2p • ♦ � vZ / / SD CURB INLET W/GRATE • 1. WILSON INV. 1N=510.40' 6" PLASTIC (SW) 6' �- 11 - a" r /l� \�, TOP (GRATE)=508.60' • INV. IN=509.40' 6" PLASTIC (NE) TMP 45-109C3 11 P II \ \ • \ %/ / INV. 1N=504.00 18 RCP (NORTH) • CHECKED BY INV OUT=509. 0 1'15" CPP II I _ INV. 1N=504.33 18 RCP WEST ch 7v LARNER, JAMES & ROX�INEII 42 ♦ ®- - \ /J / \ j INV. OUT=504.02' 18"RCP )00 • C. KOTARSKI n DB. 4826, PG. 608 1 h -- I1i1 I s••ZONED: C-1 I _ I z SCALE STRUCTURE -'--------_30_'fZCP I II _---- _ _ NOTFOUND / .� SD CURB INLET W/GRATE • ________-II --I - - -- - - -- I �/ TOP (GRATE)-509.44' � MHD SCALE 1 -30r _ _ __� _ -_ - - - - - - I / \? ;QC, , %/ INV. OUT=506.26' 18" RCP TOP=514.14' Mop N0' 60' } ry IN1N=498.89' 30"RCP 3 `� i?10, ?1S, / 0 I INV.V. 1N=508.79' 15"RCP SD INLET W/GRATE S )ffR '� / / SD CURB INLET W/GRATE TOP 528.15 2F SAFETY SLAB HT: 12.25' `(SL-1) ' FINE FINE FINE mmrlamv-.■ mto] - .. _■ MIMIC mi go ��7�1�1���� • 1 '��■IIIII���� ll���■ •. `��I�I��■���I�■IIIII����ii��ll■ ��I��I�I������I�■1IIII�����II■mil■ ��I��I�I���\��I�■11�11�•�'' III■yll■ %m�:v �Ron 'I 1' _• �Ojmml 11001001-I■ ;Ir�,,,,,_,�IHE HI■ ��I��I�►/�TiT1 ���IIII_.,,,,,,,,,,,,,,,,,,,,,,,,,, �1��I�I _■11■I� '• 1100I■11001=1■ 1 ... ��IIAII ��I��I■ FINE FINE FINE lFINE FINE I■ \III■III■I■�►�• 11�■■■ImIFINE ���II■���■I■��0�■III■■1������1��1■ ��\II■III■I■■���■IIII■■1�1\����I��1■ 1100�111Mim lmI1p"1■ II■I■ 1L...I�l..���l��l. �IFSEENIME100111�0110011001100111001100 I� irk■■1�1���1��1■ ... '��. ���■■1�\� . 11 ��I��1■ �iil� - ' - ICI �� : 1 1'�_I-■■1������1��1■ 110010011100.11 ' I�I� • ���I�■■1������1��1■ �1■I��I�I���ii�l�i'iil�■1���1��■ mm1m_�1l����I�■1��1[��IB■mml 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 530 525 540 520 535 515 530 510 525 505 520 500 515 495 510 490 505 485 14+5014+70 500 9+50 MENEM FINE 'r a owl al FINE ■■1 FINE m FINE EW FINE l001 ■1 FINE ■■I FINE FINE FINE p-lowo ANN FINE !I■ ��■1�■� //�■li-1�1'llill��� 1■ ��■1�■11■�3�31��1100111001 1■ ��■Iv■1`�,,,,,,,,, •NINE . 1 1'. I�I� ��■1�■1■1\� ��l�jy�■1■li - ����I� ����I��1■IS'' 11' i���l� MENE I■i l������1� P NOTES: 1. THESE SHEETS ARE PROVIDED FOR UTILITY PROFILE INFORMATION ONLY. 2. ALL PIPES IDENTIFIED AS'RCP' SHALL BE CLASS III RCP AND ( 1 CONFORM WITH VDOT SPECIFICATIONS. v 3. REFER TO SHEET C4.1 FOR NOTES AND DETAILS. 4. INLETS ARE DESIGNED AND IDENTIFIED AS PRECAST TOP r ^ UNITS (T-DI-3) WITH PRECAST BASE UNIT (SIZED PER VDOT V ) DETAIL) WITH INLET SHAPING. 5. CONTRACTOR TO VERIFY INLET/MANHOLE BASE SIZE WITH w MANUFACTURER TO ENSURE THE BASE CAN ACCOMMODATE THE PIPE CONNECTIONS 540 6. IF INLETS ARE INSTALLED PRIOR TO TOP LAYER OF PAVEMENT THE CONTRACTOR SHALL ENSURE RUNOFF CAN w BE CONVEYED INTO THE INLET WITHOUT PONDING AT THE GUTTER J 7. STORM SEWER TO BE PRIVATELY OWNED/MAINTAINED H 535 w u- STANDARD PROFILE LEGEND: Q 530 525 540 520 535 515 530 510 525 505 520 F(1() C.1 C. _m Ts7 � • •: rcfs7 FINE FINE m�c 11001001 ■����■ DOE _110FII �l,IIAII■■�!_ m mem■ - - v 10+00 10+50 11+00 11+50 12+00 12+50 9+50 10+00 10+50 11+00 11+50 12+00 >O// TOP o0 1A STRUCTUREID z a ELEVATION HEIGHT (TOP - INV OUT) OU Lri Lc) J Lu I 0 = X. GRADE � Q J � Q w�PROP. GRADE ~� m > a � V /DOWNSTREAM STRUCTURE w O Qm UPSTREAM STRUCTURE INLET LENGTH�N< oo_�PIPE SIZE STRUCTURE TYPE �I� O m O �� 11 o Oz m ) zz i U ONION JOB NO. 40204 515 0 12+50 0 50 PROFILE SCALE 540 535 530 525 520 5 SHEET NO. C4.2 0 a� 0 L 3 c S0 o c� 2 z ID :2 m 02 T `6 0 v � W N d 0 c � w 0 3 ZN 0 m a � x H N 0w V_ 0 0 CD � .§ a CD c Vl w �N 0.0 C 0 2 �N c_ .N• 8 C O N E C U f6 � -0 •U O C w O fN O U -0 2 C N f6 C c O O -° `0 N N t E L SL-1 45 BARS It $" C-C TYP. I I I I I I�I_I A I C I I I I A -A `• I I I I _� 30" QIAhAETER PLAN 2016 ROAD & BRIDGE STANDARDS #5 BARS e 8" C-C TYP. 30'' DIAMETER �I STPU ZE AND WALL CTHCK ETURE ISS VARIES PLAN CLASS A3 CONCRETE SECTION A -A NOTES; 1. THE STANDARD SAFETY SLAB {SL-1) IS TO BE USED ONLY WHEN SPECIFIED IN THE PLANS ON TW DRAJNAGE SUMMARY SHELT AND/OR THE DRAJNAGE ❑ESCRIPTION.FOR MANHOLES, JUNCTION BOXES, AND DROP INLETS WITH HEIGHTS GREATER THAN 12 FEET, THE 5PAGING OF ADJACENT SAFETY SLABS SHALL BE B`TO 12'WITH NO SAFETY SLAB LOCATED WITHIN 6 FEET OF THE TOP OR BOTTOM OF THE STRUCTURE, SAFETY SLABS SHALL NOT BE LOCATED BELOW ANY INLET PIPE OF 30" DIAMETER DR GREATER. 2- THE COST OF THE SL-1 IS INCLUDEO IN THE COST OF THE STRUCTURE. 3- ACCESS OPENINGS ARE TO BE STAGGERER FROM ONE SIDE OF STRUCTURE TO THE OTHER WHERE APPLICABLE- STEP$ ARE TO BE STAGGERED ACCORDINGLY - SAFETY SLAB MAY BE CASTAN-PLACE OR PRECAST. CAST -IN -PLACE CONCRETE TO BE CLASS 4 {3000 PED. PRECAST CONCRETE IS TO BE A4 {4600 PW. REINFORCING STEEL TO BE IN ACCORDANCE WITH AASHTO M31. 5, ACCESS OPENINGS MAY BE 30" DIAMETER OR 30" SQUARE. WHEN STRUCTURE WIDTH IS LESS THAN 34" THE ACCESS OPCNING SHALL SE RECTANGULAR (STRUCTURE WIDTH BY 30" LONG). CLASS A3 CONCRETE SECTION B-B SEE CAST IN PLACE DRAWINGS -OR FURTHER DETALS # 5 BARS R 8" C-C TYP. TYPICAL PRECAST UNIT xvocrrTYPICAL CONCRETE SAFETY SLAB FOR DROP INLETS, SPECIFICATION REFERENCE ROAD AND $RIDGE REVISION DATE MANHOLES AND JUNCTION BOXES SHEET 1 OF t REVISION DATE 302 106.14 VIRGINIA DEPARTMENT OF TRANSPORTATION 2016 ROAD & BRIDGE STANDARDS j i SHAPE TO ELEVATION OF MID -POINT OF LARGEST PIPE. i A 41 .e TRANSITION BETWEEN PIPE DIAMETERS WHEN DFFERENT SIZES OF PIPES ARE ENCOUNTERED. NOTES: SHAPING OF MANHOLE AND INLET INVERTS IN ACCORDANCE WITH THIS DRAWING IS TO APPLY TO THOSE STRUCTURES SPECIFIED ON PLANS OR WHERE INVERT OF PIPE IS ABOVE INVERT OF STRUCTURE. MANHOLE OR DROP INLET IS TO BE FORMED AND CONSTRUCTED IN ACCORDANCE WITH APPLICABLE STANDARD OR SPECIAL DRAWING. THE INVERT SHAPING AS DETAILED HEREON IS TO CONSIST OF A PORTLAND CEMENT CONCRETE MIX CONFORMING TO CLASS A3 OR CLASS C1 EXCEPT THAT 25X OF COARSE AGGREGATE MAY BE SLOPE TO DRAIN TO INVERT OF OUTLET PIPE SECTION A -A METHOD OF TREATMENT IN DROP INLETS SLOPE TO DRAM •• TO INVERT OF OUTLET PIPE UP TO 4" IN DIAMETER AND CONSIST OF STONE, BROKEN BRICK, o o /// •tit:ti':ifwit :. `+' BROKEN CONCRETE OR BROKEN CONCRETE BLOCK. THE SURFACE ( /�/ ::r<:;•.:•n.;i;;iti: i��{ SHALL BE LEFT SMOOTH BY MEANS OF HAND TROWELLING. NONE \ OF THE COARSE AGGREGATE SHALL REMAIN EXPOSED. , a.•.. DETAILS OF INVERT SHAPING AS SHOWN HEREON ARE FOR EXAMPLE - e • ° PURPOSES ONLY. EACH MANHOLE OR DROP INLET IS TO BE SHAPED - INDIVIDUALLY TO BEST FIT THE PARTICULAR INLET AND OUTLET CONFIGURATION AND FLOW LINES. SECTION B-B PLAN METHOD OF TREATMENT IN MANHOLES XVDOT SPECIFICATION STANDARD METHOD OF SHAPING REFERENCE ROAD AND BRIDGE STANDARDS MANHOLE & INLET INVERTS SHEET 1 OF 1 REVISION DATE 302 106.08 VIRGINIA DEPARTMENT OF TRANSPORTATION MH-1 1'-9Y4' DIA THE LETTERS V.D.O.T. ARE OPTIONAL IF USED THE LETTERS ARE TO BE 1 1/2' COVERCAST NTHE 1" WIDE RAISED 0_y"IN TOP HIGH AS F 11/z" �4" 1V2 ' SHOWN. �e .�zi =k I �•" FINISHED DIMENSION MACHINE$1- 1'-8%ems" DIA SECTION A -A B L A LETTERING OPTIONAL APPROXIMATE WEIGHT CAST IRON FRAME 239 ± 12 LBS. COVER 137 ± 7 LBS. B J ■ ■ ■ ■ ■ ■ ■ V U) l�) I � 'LimMEMOMEMEMEMEM ■ TOP 5. I T-O" DIA 5" I r� T-9-Yi" DIA �1 �+ SECTION BSECTION B-B BOTTOM XVDOT SPECIFICATION ROAD AND BRIDGE STANDARDS STANDARD MANHOLE FRAME AND COVER REFERENCE 224 SHEET 2 OF 5 REVISION DATE VIRGINIA DEPARTMENT OF TRANSPORTATION 302 106.02 302 'DOT' LABEL TO BE REPLACED WITH 'STORM' T-DI-3,4 NOTES: CURB DROP INLET THROAT SECTION 1• SEE GENRERAL NOTES - PRECAST FOR ADDITIONAL DETAILS. 2. CONCRETE TO BE 4000 PSI MINIMUM COMPRESSIVE STRENGTH. STANDARD IC-2 3. REINFORCING STEEL IN ACCORDANCE WITH ASTM A-615 FOR FRAME AND COVER 5" *4 BARS #3 BARS-, #4 BARS REINFORCING BARS. O 4. REINFORCING IN ACCORDANCE WITH ASTM A-185 FOR WELDED WIRE MESH. 5. DIMENSIONS SHOWN ARE MINIMUM. ACTUAL DIMENSIONS MAY ?0 VARY WITH MANUFACTURER. X 30' 6. THIS UNIT MAY BE USED WITH ALL STANDARD DI-3 & DI-4 CURB DROP INLETS. V�l£S FRO 7.EACH FACE BLOCK SHALL HAVE 2 OR MORE LOOPS (#3 M DOWEL HOLES C 2 �6" SEE SHEET BARS) CAST IN FACE AS SHOWN. THESE LOOPS MAY TO / 20,-0„ 2 OF 2 FOR BE USED FOR LIFT, AND FOR TIEING IN THE POURED l ALTERNATE IN PLACE GUTTER SECTION. FACE BLOCKS ARE TO BE 5" DETAIL. SEALED WITH GROUT OR POLYSULFIDE SEALER. CMIN. 8. STANDARD ST-1 STEPS NOT REQUIRED IN THIS TOP UNIT. LOCATION OF HOLE TO VARY ACCORDING TO TYPE OF INLET CONSTRUCTED. - W- W-20- FACE BLOCK SEE SHEET 2 OF 2 FOR ALTERNATE DETAIL. SEE ALTERNATE NOSE DETAIL, SHEET 2 OF 2 2'-10" ALL RIB BARS #5 ON 6" CENTERS. _ 't�v,•�•S.fss�:.:: "sue:. ::1'•'s'.'!':.r is: �: ".r% # 4 BARS 5• •3 /� ,,:. Q #.4 BARS N BARS s`. 6„ #3 BARS -- . ;' ::.'r`i :'. #4 BARS SEE ALTERNATE 1" DEEP NOTCH FOR INTERLOCK DETAIL B VARIES WITH MANUFACTURER TYPICAL MINIMUM BAR REINFORCEMENT 2'-10" ALL RIB BARS W-20 SMOOTH BARS ON 4" CENTERS. 2Ye W_20 T-71 :• •: -20 4- #4 BARS 7.1 "W-2 W-20 0 5e W-11 W-11 04 W-11 = W-20 W-20 I �• 3/2 W-20 OF W-20 W-2 W LOCATION OF HOLE TO 1" DEEP NOTCH VARY ACCORDING TO TYPE FOR INTERLOCK OF INLET CONSTRUCTED. W-11 TYPICAL MINIMUM WELDED WIRE REINFORCEMENT XVD ROAD AND RIDGE STANDARDS STANDARD PRECAST TOP UNITS SHEET 1 OF 2 REVISION DATE VIRGINIA DEPARTMENT OF TRANSPORTATION 103.05 RECOMMENDED MINIMUM HEIGHT CHART PIPE H DIMENSION 2 SIZE CONCRETE PIPE D U w 6" mQ 0 -8.. 3,_11 m 0 10„ 3,-31 12 3'-6" - 15 3 -91 18" 4'-DI 21" 4'-3 6l 3'-9„ 8" 3'-111/4. al z 10.. 4'4/4 i,i Ld 12" 4-4" 15" 4'-71/4" c 0 m U m 0 18" 4'-10'/2" d 21" 5'-1Y4" M _ 24" 5'-5" 00 o a 27" 5'-81/4" 12" 4'-4" Z)L, 15" 4'-71/4' 18" 4'-101/2" L� N 21" 5'-1Y4" mw L' am 24" 5'-5" q-0 27" 5'-81/4" UNm 6P, 30" 6'-2Y4" -em� 0 . 33" 6'-5Y4" 0 0 0� 36.- 6,-9„ 42" 7'-31/2" 48" T-10" SPECIFICATION REFERENCE 105 233 302 MH-2 FOR DETAILS OF ALL COMPONENT PARTS AND "GENERAL NOTES- PRECAST" SEE SHEETS 103.01-103.11 SPACER UNIT A ' r r --� - ° � ----- �- RISER UNIT W ° LL - - - - Z i _ - - - ° RISER UNIT !E RISER (UNIT REDUCER z J l l REDUCER UNIT rl'r MONOLITHIC - 1-- BASE -- ° -- BASE � UNIT BASE UNIT I T I _r,_� E17t FOOTING EL FOOTING SPECIFICATION XVDT REFERENCE PRECAST MANHOLE ROAD AND BRIDGE STANDARDS 105 302 VIRGINIA DEPARTMENT OF TRANSPORTATION REVISION DATE SHEET 1 OF 1 106.07 PB-1 NO PROJECTION OF PIPE ABOVE GROUND LINE TOP OF FILL TOP OF FILL TOP OF FILL GROUND LINEPF GROUND LINE = GROUND LINE x '' 1I I1=1I1=1 rrrrrr rrrr III=1 =III =1 I=1 I� rrrrrr rrrr III-III=1 I - =1 I=1 =1 rrrrrrr rrrrrr III=III=1 I- I-1 1 II rrr 11 EARTH rrr I r r rr EARTH I II a r I I� + rrr d 11 ROCK OR d 1 II II. Ell SOILIELDING I II. o II I- BEDDING o _I II o 7 I MATERIAL MIN. 1/10 D X D X BEDDING j jI p p --- - X D X BEDDING MIN. 1/10 D MATERIAL - E MATERIAL X I D X '/2" PER 1' OF H MIN. 8", MAX. 24" FOUNDATION SOFT, YIELDING, OR NORMAL EARTH FOUNDATION ROCK FOUNDATION OTHERWISE UNSUITABLE MATERIAL PIPE PROJECTION ABOVE GROUND LINE LIM MIN. 1.5 x D MIN. 1.5 x D MIN. 1.5 x D MIN. 1.5 x D MIN. 1.5 x DI MIN. 1.5 x D TOP OF FILL TOP OF FILL TOP OF FILL m = as = rrrrrrrrrrrrrrr rrrrrrrrrrrrrrr - x } rrrrrrrl rrrrrrr.; _ - rrrrrr rrrrrrr • _ - .;rrrrrrr rrrrrr;. - - •rrrr N = rr = = rr rr : - + r d :GROUND = rrrrr rrrrr : - _N - :rrrr rri :rrr rr :: + GROUND - rrrrrrrrrrrrrr rrrrrrrrrrrrr - _ - rrrrrrrrrrr rrrrrrrrrrr = N rrrrrrrrrr rrrrrrrrrr - - rr LINE r d rr;•;;•;;{�; o =��N LINE -rrrrrrrrrr d rrrrrrrrrr + GROUND 0 N _ - LINE III III -III -I IJ I11 I EARTH M I I I I I UNYIELDING MIN. 1/10 D - ROCK ORIMIN. _=III-- -. ; 0=4 1/10 D X D X BEDDING MATERIAL i /2 PER SOIL 1" OF H X D X _- - -i i-iTi-iTi-i �i i- - MIN.1/10 D t� BEDDING MIN. 8", BEDDING EARTH MATERIAL MAX.24" MATERIAL FOUNDATION SOFT, YIELDING, OR NORMAL EARTH FOUNDATION ROCK FOUNDATION OTHERWISE UNSUITABLE MATERIAL BEDDING MATERIAL IN ACCORDANCE WITH EMBANKMENT NOTES ® SECT ON 302 OF THE ROAD AND BRIDGE SPECIFICATIONS, FOR GENERAL NOTES ON PIPE BEDDING, CLASS I BACKFILL MATERIAL IN ACCORDANCE SEE INSTALLATION OF PIPE CULVERTS WITH SECTION 302 OF THE ROAD AND BRIDGE AND STORM SEWERS GENERAL NOTES SPECIFICATIONS. ON SHEET 107.00. REGULAR BACKFILL MATERIAL IN ACCORDANCE FOR PLASTIC PIPE CLASS I BACKFILL MATERIAL WITH SECTION 302 OF THE ROAD AND BRIDGE rr��r SPECIFICATIONS. CRUSHED GLASS CONFORMING TO THE IN ACCORDANCE WITH SECTION 302 OF THE ROAD SIZE REQUIREMENTS FOR CRUSHER RUN AND BRIDGE SPECIFICATIONS. AGGREGATE SIZE 25 AND 26 MAY BE USED IN PLACE OF CLASS I BACKFILL. FOR ALL OTHER PIPE REGULAR BACKFILL MATERIAL IN ACCORDANCE WITH SECTION 302 OF THE ROAD AND BRIDGE SPECIFICATIONS. XVDOT INSTALL. OF PIPE CULVERTS AND STORM SEWERS SPECIFICATION REFERENCE ROAD AND BRIDGE STANDARDS CIRC. PIPE BEDDING AND BACKFILL - METHOD ''A'' 302 SHEET 1 OF 4 REVISION DATE 07/12 VIRGINIA DEPARTMENT OF TRANSPORTATION 303 107.01 1 J i ='H O 0, CRAIGW 3. K9FARSKI Lic. No. 0402048507 Y M E CD 0 M U N u� N C Q U > E Lu E Lu U � � LL i n Lu 0 16 � QJ U000 a J H d >C) N N C7 W :1X LL Q : (n = N Ln N = U > F_ Q c Ln O� 4 N N M a� GO J Lu LD F_ CL O c� z O I - a U U) w 0 z O U) Lu W W C) C) W W Q_ CL 0 Q j LLI Lu CIO CIO w O N Q rj ti C) O DATE 04109118 DRAWN BY 1. WILSON DESIGNED BY 1. WILSON CHECKED BY C. KOTARSKI SCALE o Uai U)^CL , U V / c N 0 Lum J U N 0 n 0 c 6s 0 6) Lu N a ma J o c i jIll-4 m J a caii} v c 6s z 1= 11 1 a O�■. LLJ Lu Q `o W 0 J J 3 Q •c Lu LL =o o O z a °z 00 ( ^ 2 v J o uj co E � O -0 C C N 65 N 0_ O Z) U Oc: � w O Z 3 zN J 2 a 2 x N m o w 0 aw o T a li o c E Y N U +0+ XN U C N O O U 2 ca C O V) U C O N E 7 C U 63 -a 6 0.6) 'a f6 .2 •U � JOB N0. ° o U 40204 ccU) U) O C SHEET NO. a o C4.3 s ] L OFFSITE TO BERKMAR DR AREA = 0.30 ACb STORMWATER MANAGEMENT NARRATIVE' THE SITE HAS THREE MAJOR OUTFALL LOCATIONS: IMPERVIOUS =0.12 AC PERVIOUS - 0.00 AC �� 0 � BERKMARK DR THIS OUTFACE IS LOCATED AT THE ,' - FOREST - 0.18 AC � , to �OFFSITE TO EX SWM BERK A DR \ Ss�o EASTERN SIDE OF THE SITE. WATER FROM THE EXISTING CRAMW3.i{O'FARSK]C A AREA = 1.23 AC \ \ I P \ I DEVELOPMENT IS CONVEYED IN PIPES IN BERKMAR DRIVE Lic. No. 0402048507 r IMPERVIOUS = 0.52 AC \ I/ -I I� i ��i ,�� PERVIOUS = 0.71 AC � � l � r � �° A � � h ULTIMATELY OUTFALLING IN A MAN MADE DITCH THAT DRAINS TO KEGLERS POND. b to/12/i8 ,�( - FOREST - 0.00 AC \ ► I r r 7i �g*104 � e ri,h � coTHERE h \ 3 /vt�L��/, I ' '� IS AN INCREASE OF TOTAL AREA AND FLOW FOR rrr 0 ' r / 562 � l THIS DRAINAGE AREA FROM PRE -POST DEVELOPMENT. _ i p h� , �� l r / /� rr y� / y6 5ys _65022 \ , , r , / t - �-� iee , I z HOWEVER THE PROPOSED UNDERGROUND DETENTION \ TO BERKMAR DR (PIPES) �- -_ �'� \� \ SYSTEM DETAINS THE INCREASED FLOW. N AREA = 1.31 AC �� - SCALE 1"=100' ` - - -55 >g"rti N u� > 0 ,�- ss4 - - - - - � � � x IMPERVIOUS =0.23 AC-';--�_1-- - - - v- \71, ' \ , ERKMAR DR INLET 1 PERVIOUS = 1.07 AC EX SWM SYSTEM - THIS OUTFALL IS LOCATED ON THE SOUTHERN END OF THE SITE. A PORTION OF THE WATER > E = -' > _ - FOREST = 0.01 AC ,; / �3 AREA = 0.47 AC 0 160 200 �-'� FROM THE EXISTING SITE DRAINS TO AN UNDERGROUND W Lu ¢ � -E _ .� �/ N f IMPERVIOUS =0.15 AC 550 26. , ' ' " �` '% = y , i �r/%// �, 6-- PERVIOUS = 0.26 AC / DETENTION SYSTEM WHICH DISCHARGES TO A LL o _ ' , - _ - - - _ %� q / ,�: �' 648 �� , -- _ _l , \ � �/rai � �% r / II k� rrr/ FOREST = 0.06 AC BIORETENTION SYSTEM. THE OUTFALL FROM THE L M Q v w� -Ln z o �- `-- ,% \ \ \ I r BIORETENTION ENTERS A PIPE SYSTEM THAT PASSES > o \ �e yAl �% \ I r UNDER BERKMAR DRIVE THAT OUTFALLS TO A MANMADE vi W a ` m o /i//r/ ;% ' , �h�'/ r r► %' BERKMAR DR INLET 2 DITCH THAT DRAINS TO KEGLERS POND. o u Luu AREA = 0.06 AC ' /�/ in Q f / / r //r / \ _ TO EX SWM l / , \� r r/�ir / IMPERVIOUS =0.06 AC '� ��� �� \r THERE IS AN INCREASE IN IMPERVIOUS AREA FROM THE PRE TO POST DEVELOPED CONDITION IN THIS DRAINAGE ,,, x = N u ; z p ,k - AREA = 2.60 AC h / /�//r��/� PERVIOUS = 0.00 AC IMPERVIOUS =1.15 AC���/rir r FOREST 0.00 AC AREA. HOWEVER AN UNDERGROUND DETENTION SYSTEM o� N cn = \ ► o\ _, r rrir LL>, c� OFFSITE TO 30 RCP _- - -_ _ - �� \ _ \ �, \ PERVIOUS = 1.05 AC / 1, r \ \\ /� �rr��i / ® _ - BERKMAR DR INLET 3A \ ` `�� FOREST 0.40 AC IS BEING INSTALLED TO DETAIN THE FLOW. THE OUTFACE a z z AREA = 9.96 AC - - _ ,_ = r , / -�--- AREA =0.44AC FROM THE PROPOSED DETENTION SYSTEM TIES TO THE o w IMPERVIOUS =0.08 AC ��p9'-- ,���'��'/ �\` ��`� / r/r l 7 - - \ss\ r l '�\ Z`\ / rrr IMPERVIOUS =0.11 AC 'q3 - OUTFACE PIPE FROM THE BIORETENTION FILTER PRIOR o 0 PERVIOUS = 0.31 AC , ' - - - - ' ��' - rir - - ,���/ l q2 E , \ ` 1 l l r r % �- \ r�/ PERVIOUS = 0.15 AC - - \ / //i TO LEAVING THE SITE. w w FOREST = 9.57 AC �\ \ \ N�1a15 rrr / / e - \ _ _ _ \ ; , �\ \� - r 11 fj�_ _ _ =_ e r r �� �. - - e� , r - �� sir r FOREST = 0.18 AC \ vi ? a a ��\\\ r �/r o / _ , / / ' /� _ -� - = _ - _.� r e I \ r r BERKMAR DR INLET 3 \ �\ m �'I' ` 30 RCP CULVERT - THE WESTERN END OF THE SITE DRAINS TO AN EXISTING 30" CULVERT. THIS CULVERT 0 = w cn w cn ,' ,�rir r AREA =0.30AC I _ \ _ _ e_ _ - % r IMPERVIOUS ACOf ENTERS A PIPE SYSTEM THAT PASSES UNDER BERKMAR o � cz \\\\\\\\` \� \� _ _ _ _ _ _ _ _ _ _ I r, =0.30 \\\ \\ \\\\\ \ \ \ I I I I I 1 �� -� -_ - _ _ _ - _- - o \ a %./� , ` �� o, / \\\\ \ \ \\\ TO 30 RCP _ _ _ _ __ / _ \\ �525---,/ / PERVIOUS = 0.00 AC ` DRIVE AND OUTFALLS TO MANMADE DITCH THAT DRAINS _ \\ \ _ --- \ r \ I \ - _ - =N6 _ _ ' _ �_ = _ _ �- J '� - \\\\\\\\ \\\ . \ \ AREA = 3.45 AC _ _ -��> > - FOREST = 0.00 AC TO KEGLERS POND. o w IMPERVIOUS =0.03 A C 520 ----- -�8 �� - �__ / // ERKMAR DR INLET4A PERVIOUS = 0.30 AC ��\ - / �,/I -////r / `� v Lu < o N� n C \�\\ _ ; ,_ _ _ _ _ _°�'_ _ _ _- _520 _ _ �,� I AREA = 0.34 AC THE TOTAL AREA IN THIS DRAINAGE AREA IS REDUCED a o'- _ _ _ _ _ \\`scr �o\\\ �\�\ \\i FOREST=3.12AC \�\-- ---- ---_ -��_-- - - �• I �,�/r ' \ __ _ \__ _ -- ► 15. r ` IMPERVIOUS =0.07 AC o 515 \ \ FROM THE PRE TO POST DEVELOPED CONDITION. ADDITIONALLY THERE IS A SLIGHT INCREASE IN PERVIOUS z �_ PERVIOUS = 0.17 AC DATE \\ \� \\ \ _ vvm , , pl FOREST = 0.10 AC \ AREA FROM PRE TO POST DEVELOPMENT. Of 04/09/18 BERKMAR DRINLET 4 POINT DRAWN BY AREA KEGLERS LIMITS OF ANALYSIS (CHANNEL & FLOOD PROTECTION). } POINT 1 - THE DOWNSTREAM CONDITION BEYOND THE IMPERVIOUS =0.10 AC POND \\ s \ \\ \ \� r `- �P PERVIOUS = 0.00 AC SITE OUTFALL IS A SERIES OF MANMADE STORMWATER J. WILSON DESIGNED BY J. WILSON FOREST = 0.00 AC \ \ \ %' \ ` \\ �\� \ \ \\ l\\\� \\ \ \\ \ \ �` \ \\ \ \ \�\ \\� - - --- __ MANAGEMENT SYSTEMS AND CONVEYANCE SYSTEMS. THE PROPOSED LIMIT OF ANALYSIS IS THE EXISTING • • \\\\ \\ \\\� \\\\ \ \\ \ r , 8 0 00 - \ STORMWATER MANAGEMENT POND (REFERENCES AS TO BERKMAR DR (SHEETFLOW) \ \\ 30"R P, THE REGIONAL KEGLERS POND) WHICH WAS STUDIED CHECKED BY % _ _ r AREA = 0.28 AC 0/r; _ _ \ OUT ALL � POI T -' X SWM IMPERVIOUS =0.00 AC UNDER THE BERMKAR DRIVE NORTH EXTENSION EXISTING "KEGLER'S- DETENTION BASIN STORMWATER • • C. KOTARSKI OUTFACE PERVIOUS 0.28 AC \ � SCALE = ._\ ' ' POINT ANALYSIS" BY ALBEMARLE COUNTY ENGINEERING _ FOREST = 0.00 AC DEPARTMENT (MARCH 1994). THE CONVEYANCE SYSTEM / FROM THE DISCHARGE CULVERT THROUGH THE � OFFSITE TO BERKMAR DR \ _ AREA = 0.30 AC / / MANAMDE CHANNEL INTO THE POND WAS RECENTLY IMPERVIOUS =0.12 AC \ ED ANALYZED BY HARVEST MOON - PHASE 1 (WP0201600011) PERVIOUS = 0.00 AC TO DEMOSTRATE ADEQUACY OF THE CONVEYANCE `__ OFFSITE TO EX SWM FOREST = 0.18 AC , _ \\ SYSTEMS TO KEGLERS POND. THE PROPOSED OUTFALL 0 C CONDITION REDUCES THE 1 AND 10 YEAR PEAK AREA = 1.23 AC I \ I a IMPERVIOUS = 0.52 AC \ r \ \/fir I�r , a2 \ BERKMAR DRIL DISCHARGE. Q PERVIOUS = 0.71 AC ,, r / I I ► >° OUTFALL \ I�r ' FOREST = 0,00 AC l r i POINT r, F ►�I I >04, �3 / � r , �/L? � , l � r r � ' , WATER QUALITY THE PHOSPHOROUS REMOVAL REQUIREMENT FOR THE `/ CL ��t\` co 56 2 r e r 00 SITE, AS IDENTIFIED IN THE VRRM SUMMARY PAGE ON h`' ,r f r ' r TO BERKMAR DR (PIPES) /rr ERKMAR DR INLET 1 o -l" / Q ' ' AREA = 0.45 AC z SHEET C5.2, WILL BE MET THROUGH A THE PURCHASE OF NUTIRENT CREDITS AND THE INSTALLATION OF w z AREA = 1.36 AC ��/�i� ,, _ %,' IMPERVIOUS =0.27 AC = - _ \ IMPERVIOUS =0.15 AC PERVIOUS = 0.26 AC STORMCEPTOR SYSTEMS. J J \`�','p" PERVIOUS = 1.09 AC ^�..� �� \ ss SCALE 1"=100' M`''��1\ �- _ '_ -�-' FOREST - 0.00 AC _ FOREST = 0.04 AC Q 0 160, 260' �� WATER QUANTITY 550 ,' - ' y PRop �i�/Nr�� �\ BERKMAR DR INLET 2 THE SITE IS CURRENTLY AN ANIMAL SHELTER AND w - y6� , y 2 r o� _ _ _ 4 _ - = P//,\ V ,� \ �r AREA = 0.06 AC PARKING LOT. THE PROPOSED DEVELOPMENT INCLUDES 548 -off , _ ^ � - ' � _ - - � /;/ � y � � / � IMPERVIOUS =0.06 AC ADDITIONS PARKING LOTS AND ASSOCIATED w a PERVIOUS = 0.00 AC FOREST 0.00 AC INFRASTRUCTURE. � > Irrnn w = V 16 <\ SWM B CHANNEL PROTECTION z Q AREA 0.42 AC AREA THE SITE DEVELOPMENT DISCHARGES CONCENTRATED z � \ � / - TO EX SWM r r rr �' 'O IMPERVIOUS =0.37 AC AREA = 1.57 AC /i / STORMWATER RUNOFF INTO A CONVEYANCE SYSTEM AND THEN DISCHARGES TO KEGLERS POND. THE THREE U w w Q r8„ \ / \ r PERVIOUS = 0.05 AC �' / J C IMPERVIOUS =0.96 AC I o; \ _�' - /' r/rr/i/i PERVIOUS FOREST - O.00AC ® MAJOR OUTFALLS ENTER A MANMADE DITCH AT APPROXIMATELY THE SAME LOCATION BEFORE DRAINING Q = w G '/1 \. \ FOREST = 0.00 AC r = _ _ - ' yv� r� / BERKMAR DR INLET 3A OFFSITE TO 30" RCP O9_ _ _ - , ' 4r - / / ,fir AREA = 0.34 AC TO KEGLERS POND. THE POST DEVELOPED FLOW IS BEING REDUCED TO BE LESS THAN THE PREDEVELOPED ~ m > Q w qg7 low- 'rrr�/ AREA = 9.96 AC 'E J \ IMPERVIOUS =0.08 AC �\ \ \ 71°�5�2r /r _ - - _ _ , r/ IMPERVIOUS =0.11 AC - / � ;, - - /, r j ��/ r PERVIOUS = 0.15 AC FLOW. COMPUTATIONS ARE PROVIDED ON SHEET C5.1. Q - PERVIOUS = 0.31 AC \\\\ I r /c \ e ,' , ,` ' TO SWM A \� r e /rr FOREST = 0.08 AC THESE VALUES INCLUDE THE OFFSITE CONVEYANCE UP Lu FOREST = 9.57 AC `\ II \I `\ I \ I I r ' / ,- - „. ' u_ `� ' _ e� ' \ \ \\\\\\\II ' _ AREA 1.02 BERKMAR DR INLET 3 \ \ \ IMPERVIOUS AC '� ' ' STREAM FROM THE SITE. THE OUTFACE IS A MANMADE CHANNEL/MANMADE POND. \ =0.52 \� AREA = 0.30 AC % \ II \�\" `"\ \\ \ \\\ \`\ \\ \\ - - _ ` - PERVIOUS - 0.50 AC 'e / \ \ \ \ \ \ \I I 1 _ :.. y TO 30 RCP - - - - - Jac` PL �, ,r r IMPERVIOUS =0.30 AC THIS POST -DEVELOPMENT CONDITION SATISFIES 9VAC870-66 B.1.(a). _ FOREST = 0.00 AC AREA = 2.85 AC / / PERVIOUS = 0.00 AC \ \ \ \ ' - '� // /r O O \ \ \ \ \\\ \ \ \\ \\\\\\\ \\ \\\ \ \�cr \ - - _ _ - 5 5 r FOREST = 0.00 AC \ \ \ \ \ \ \ \\ \\\\\\\ �\ \w� \ IMPERVIOUS =0.00 AC O• � ti Q' BERKMAR DR INLET 4A FLOOD PROTECTION J F \ \\ \ \ \ \ \ \\\\\ \, �s \\ o\ \\\\ PERVIOUS = 0.33 AC �� - - ; - _ - _ O HE CONCENTRATED STORMWATER FLOW FROM THE ` '�` \\`r\` \ \ FOREST = 2.52 All -- - - - , Q�� �Q' J� O�'j, ,'/4 I AREA = 0.30 AC tw,NIATEHLWE-___ _ r tip` �JZ �� ,5�5 r r / 0 IMPERVIOUS =0.07 AC \ \ L \\ \� SITE HAS BEEN ANALYZED FOR THE 10 YEAR STORM TO Q \\\I I�` \ ` `\\ - /, `\ ` - - -pRo� _ _ I \�`` \ \\\�`�_�\���: \"\ \\\ \� \-------VUNf J �_- _ �8�-p Q O�� rr / PERVIOUS=0.17AC \ pl VERIFY THAT FLOOD PROTECTION REQUIREMENTS HAVE \\ - - - - - - P�P°�E°�`�� \ \ \ \ ` � \ I I - - \\ \ \\ \ \ \\ " \• • \ � ` ` \ ` _ _ - _ - - SAOIITA@ySEWER r , �. IV n Q r FOREST = 0.06 AC BEEN SATISFIED. THE SITE DOES NOT EXPERIENCE \�\\ BERKMAR D R INLET LET 4 POINT 1 \`• I AREA = 0.10 AC ss2jS� LOCALIZED FLOODING. COMPUTATIONS ARE PROVIDED V KEGLERS �� �S�o �\� `� ' �� ,� ��� - \` ';r % r ° r IMPERVIOUS =0.10 AC ON SHEET C5.1 \ \ - \ \ \ \\ \ POND \N PERVIOUS = 0.00 AC AS REQUIRED BY CONDITION 9VAC-870-66 C.1, V` \�` r/ I >\ - POST -DEVELOPMENT FLOWS ARE CONFINED TO THE \ \\ \moo` \ \� \ \\ \\�� FOREST 0.00 AC --- s , STORMWATER CONVEYANCE SYSTEMS. \ ,.... on n11 r TO BERKMAR DR (SHEETFLOW) \\\ NOTES: JOB NO. 40204 \\ I I I I I I \ \ \ \\ err/\_a \ 30" R AREA = 0.28 AC I I �111 I I� I I I I OUT AL Ex swM IMPERVIOUS =0.00 AC 1. UPSTREAM DRAINAGE AREAS BASED ON PREVIOUSLY APPROVED PLAN SHOWN ON SHEET POINT'OUTFALL PERVIOUS = 0.28 AC / C5.3. POINT FOREST = 0.00 AC ' ' 2. SURVEY INFORMATION ON THIS SHEET BEYOND SHEET NO. -- PROPERTY LINE IS DERIVED FROM COUNTY GIS. CS. 0 L INLET SUMMARY ROUTE Berkmar PROJECT CASPCA DESIGNER: CG r.HFr.KFn• DATE 10/12/2018 I INITS:NrI ISH INLET a a �r 3 a a C, A Sag Inlets Only F., F x 1C1 DI-3B 6.000 0.130 0.90 0.117 0.000'RIGH 0.040 0.35 0.014 0.131 4 0.524 0 0.524 0.0100 0.0200 4.096 2.000 0.488 0.0620 3.1 0.925 3.01 0.1253 0.1360 4.727 6.000 1.269 1.000 0.524 0.000 1.991 1C2 DI-3B 6.000 0.160 0.90 0.144 0.000'RIGI 0.040 0.35 0.014 0.158 4 0.632 0 0.632 0.0100 0.0200 4.611 2.000 0.434 0.0620 3.1 0.889 3.01 0.1253 0.1314 5.220 6.000 1.149 1.000 0.632 0.000 2.115 10 DI-3B 6.000 0.020 0.90 0.018 WRIGHT 0.010 0.35 0.004 0.022 4 0.088 0 0.088 0.0100 0.0200 1.399 2.000 1.43 0.0620 3.1 1.000 3.01 0.1253 0.1453 2.147 6.000 2.795 1.000 0.088 0.000 1.041 2F DI-3B 6.000 0.180 0.90 0.162 0.000'RiGH 0.050 0.35 0.018 0.18 4 0.72 0 0.720 0.0100 0.0200 4.980 2.000 0.402 0.0620 3.1 0.861 3.01 0.1253 0.1279 5.604 6.000 1.071 1.000 0.720 0.000 2.203 2H DI-3C 10.000 0.520 0.90 0.468 Back/Lt. 0.000'RIGH 0.180 0.35 0.063 Back/Lt. 0.531 4 2.124 0 0.0010 0.0200 13.887 2.000 0.144 0.0620 3.1 3.01 Back/Lt. 0 4 0 0 Ahead/Rt. 2.124 0.0010 10 2.124 1.995 0.160 0.500 0.32 3.995 8.315 T> 8.0 ft 3A DI-3C 6.000 0 4 0 0 Back/Lt. 0.000'RIGH 0.200 0.90 0.18 Ahead/Rt. 0.200 0.35 0.07 Ahead/Rt. 0.25 4 1 0 0.0010 0.0200 10.173 2.000 0.197 0.0620 3.1 3.01 Ahead/Rt. 1.000 0.0010 6 1.000 1.523 0.160 0.500 0.32 3.523 6.346 T> 8.0 ft PIPE (LINK) SUMMARY LD-229 PROJECT: CASPCA STORM SEWER DESIGN COMPUTATIONS LOCATION: Charlottesville COUNTY: Charlottesville STORM FREQUENCY 10 Designed by: CG Checked by: UNITS I ENGLISH PIPE NO. FROM POINT TO POINT DRAIN. AREA "A" Acre (3) RUNOFF COEFF. "C" (4) CA INLET TIME Minutes (7) RAIN FALL In/Fh- (8) RUNOFF INVERT ELEVATIONS LENGTH of Pipe Ft. (12) SLOPE Ft./Ft. (13) SIZE (Dia. Or Span/Rise) In. (14) SHAPE Nuunber of Pipes Capacity CFS (15) Friction Slope Ft./Ft. NORMAL FLOW FLOW TIME REMARKS (18) INCRE- MINT (5) ACCUM- ULATED (6) Lateral CFS Total Q CFS (9) UPPER END (10) LOWER END (11) Depth of Flow, du Ft. Area of Flow, An SgFt Hrn Ft. Vn Ft/Sec (16) En Ft. INCRE- MENT Minutes (17) ACCUMU -LATER Minutes (17) REFERENCE (1) STA. REFERENCE (2) STA. 1(17) 3A OUT- 11(17) 0.40 0.63 0.25 0.25 5.00 5.04 0.00 1.26 534.43 528.87 101.46 0.05480 15 Circular 1 15.12 0.00040 0.24 0.17 0.15 7.47 1.11 0.23 5.23 IBA 1B EXl 0.00 0.00 0.00 5.03 5.03 0.00 2.44 514.82 513.05 51.65 0.03427 15 Circular 1 11.96 0.00150 0.38 0.32 0.22 7.65 1.29 0.11 5.15 1 C 1 C 1 C 1 1 C 0.17 0.77 0.13 0.31 6.13 4.76 0.00 1.52 527.05 526.75 30.30 0.00990 15 Circular 1 6.43 0.00060 0.41 0.35 0.23 4.29 0.70 0.12 6.24 1C21 1C2 1C1 0.20 0.79 0.16 0.18 5.83 4.83 0.00 0.89 528.61 527.15 81.01 0.01802 15 Circular 1 8.67 0.00020 0.27 0.20 0.16 4.56 0.59 0.30 6.13 1C32 1C3 1C2 0.03 0.73 0.02 0.02 5.00 5.04 0.00 0.11 530.91 528.71 122.18 0.01801 15 Circular 1 8.67 0.00000 0.10 0.05 0.06 2.46 0.19 0.83 5.83 1CB 1C 1B 0.00 0.00 0.00 5.00 0.00 0.00 2.44 523.14 523.04 9.67 0.01034 15 Circular 1 6.57 0.00150 0.53 0.49 0.28 4.96 0.91 0.03 5.03 2BA 2B 2A 0.00 0.00 0.00 5.07 5.02 0.00 5.42 509.07 508.55 51.62 0.01007 15 Circular 1 6.48 0.00730 0.87 0.92 0.37 5.91 1.42 0.15 5.22 2CB 12C 2B 0.00 1 0.00 0.00 5.00 0.00 0.00 5.42 509.42 509.17 24.72 0.010111 15 Circular 1 6.50 0.00730 0.87 0.92 0.37 5.92 1.42 0.07 5.07 2ED 2E 21) 0.00 0.00 0.71 5.62 4.89 0.00 3.56 515.55 515.08 46.58 0.01009 15 Circular 1 6.49 0.00320 0.66 0.66 0.32 5.41 1.12 0.14 5.76 2FE 2F 2E 0.23 0.78 0.18 0.71 5.54 4.90 0.00 3.56 515.90 515.65 25.28 0.00989 15 Circular 1 6.42 0.00320 0.66 0.66 0.33 5.37 1.11 0.08 5.62 2GF 2G 2F 0.00 0.00 0.53 5.15 5.00 0.00 2.68 519.86 519.06 106.81 0.00749 15 Circular 1 5.59 0.00180 0.61 0.59 0.31 4.51 0.93 0.40 5.54 2HG 2H 2G 0.70 0.76 0.53 0.53 5.00 5.04 0.00 2.68 520.75 519.98 51.46 0.01496 15 Circular 1 7.90 0.00180 0.50 0.46 0.27 5.82 1.03 0.15 5.15 LINK-04 STR A STR B 0.55 0.90 0.50 0.50 5.00 6.54 0.00 3.24 539.00 537.70 73.00 0.01781 15 Circular 1 8.62 0.00260 0.53 0.50 0.28 6.52 1.19 0.19 5.19 LINK -OS STR B STR C 0.00 0.00 0.50 5.19 4.99 0.00 3.24 537.60 535.66 105.00 0.01848 15 Circular 1 8.78 0.00260 0.53 0.49 0.28 6.61 1.21 0.27 5.45 LINK-06 STR C 3A 0.00 0.00 0.50 5.45 4.93 0.00 3.24 535.56 534.46 22.90 0.04803 15 Circular 1 14.16 0.00260 0.41 0.35 0.23 9.36 1.77 0.04 5.49 Rjer MATERIALS" Concrete Pipe Division OSR 140 Precast Concrete Stormceptor® (900 U.S. Gallon Capacity) Stormceptor Frame and Cover Grade Adjusters to Suit Finished Grade 8 n Varies Inlet 55" Min. �{ 8" 8" F T__ 72"0 Stormceptor Insert 32" 0 I 30" 0 Drop Tee \ Inlet Pipe Drop Outlet Pipe d: O AQ A '•Q Orifice Plate 6" 7" Oil Port Outlet Section Thru Chamber Inlet Insert Rotated 5° CCW I Access opening (See note #2) Outlet Pipe Plan View Notes: 1. The Use Of Flexible Connection is Recommended at The Inlet and Outlet Where Applicable. 2. The Cover Should be Positioned Over The Outlet Drop Pipe and The Oil Port. 3. The Stormceptor System is protected by one or more of the following U.S. Patents: #5753115, #5849181, #6068765, #6371690. #7582216, #7666303. 4. Contact a Concrete Pipe Division representative for further details not listed on this drawing. Oil Port Rjer MATERIALS" Varies 21" 17" 90" Min. Concrete Pipe Division OSR 390 Precast Concrete Stormceptor (4800 U.S. Gallon Capacity) Stormceptor Frame and Cover - Grade Adjusters To Suit Finished Grade Section Thru Chamber Insert Rotated 5° CCW Access opening (See note #2) Notes: 1. The Use Of Flexible Connection is Recommended at The Inlet and Outlet Where Applicable. 2. The Cover Should be Positioned Over The Outlet Drop Pipe and The Oil Port. 3. The Stormceptor System is protected by one or more of the following U.S. Patents: #5753115,#5849181,#6068765,#6371690.#7582216,#7666303. 4. Contact a Concrete Pipe Division representative for further details not listed on this drawing. STORM SEWER COMPUTATION NOTES THIS SHEET IS ONLY INTENDED TO PROVIDE HYDROLOGIC AND HYDRAULIC COMPUTATION INFORMATION. REFER TO STORM PLAN/PROFILES FOR DESIGN INFORMATION (LENGTH, INVERTS, SIZE, ELEVATIONS, ETC). 1. STORM EVENT MODEL IS DERIVED FROM NOAA DATA (CHARLOTTESVILLE, VIRGINIA, USA) TO DEVELOP A 24 HOUR RAINFALL EVENT (TYPE II DISTRIBUTION). 1.1. STORM 01 YEAR - 3.01" 1.2. STORM 10 YEAR - 5.51I 2. HYDROLOGIC COMPUTATIONS PROVIDED ARE BASED ON TR-20 METHODOLOGY. 2.1. IMPERVIOUS RUNOFF CURVE NUMBER = 98 2.2. TURF RUNOFF CURVE NUMBER = 61 2.3. FOREST, OPEN SPACE, UNDEVELOPED CN = 55 3. HYDRAULIC COMPUTATIONS FOR THE CLOSED CONDUIT SYSTEM ACCOUNT FOR INLET SHAPING (0.5 X HEAD LOSS) 4. INLET COMPUTATIONS ASSUME 2" LOCAL DEPRESSION FOR INLETS LOCATED ALONG A CURB. 5. AREAS LISTED IN VRRM SPREADSHEET (ON C5.2) IS BASED ON DISTURBED AREA. A LARGER AREA DRAINS TO THE SITE OUTFALL. SEE SHEET C5.0 SUBBASIN SUMMARY TORMWATER MANAGEMENT) THIS SUMMARY IS FOR THE ENTIRE SITE, AS WELL AS ANY OFFSITE AREAS IT IS MODLED USING THE 1 YR STORM Subbasin Summary Subbasin Area Weighted Total Total Total Peak ID Curve Rainfall Runoff Runoff Runoff Number Volume (ac) (in) (in) (ft3) (cfs) Time of Concentration (days hh:mm:ss) OFF_30IN 9.96 56 3.01 0.21 7629 1.7 0 00:05:00 OFF _301N_PRE 9.96 56 3.01 0.21 7629 1.7 0 00:05:00 OFF _BERKMAR_POST 0.30 72 3.01 0.82 897 0.4 0 00:05:00 OFF _BERKMAR_PRE 0.30 72 3.01 0.82 897 0.4 0 00:05:00 OFF _BIO_POST 1.23 77 3.01 1.06 4719 2.0 0 00:05:00 OFF _BIO_PRE 1.23 77 3.01 1.06 4719 2.0 0 00:05:00 Post_301N_RCP 2.85 56 3.01 0.22 2224 0.5 0 00:05:00 Post_BERKMAR 1.36 68 3.01 0.65 3194 1.2 0 00:05:00 Post_Berkmar_Sheet 0.28 61 3.01 0.37 375 0.1 0 00:05:00 Post _Bio_Out 2.01 78 3.01 1.14 8332 3.6 0 00:05:00 Post_New_Det_01 1.02 80 3.01 1.25 4625 2.0 0 00:05:00 Post_ New _Det_02 0.42 94 3.01 2.32 3537 1.5 0 00:05:00 Pre_301N_RCP 3.45 56 3.01 0.22 2755 0.7 0 00:05:00 Pre_BERKMAR 3.30 72 3.01 0.80 9631 3.9 0 00:05:00 Pre-Bio 2.60 76 3.01 1.05 9872 4.2 0 00:05:00 S_4A 0.30 68 3.01 0.65 708 0.3 0 00:05:00 S_In1 0.45 73 3.01 0.85 1393 0.6 0 00:05:00 S_In2 0.06 98 3.01 2.76 601 0.2 0 00:05:00 S_In3 0.30 98 3.01 2.78 3025 1.2 0 00:05:00 S_In3A 0.34 72 3.01 0.79 979 0.4 0 00:05:00 S In4 0.10 98 3.01 2.77 1007 0.4 0 00:05:00 SUBBASIN SUMMARY (STORMWATER MANAGEMENT THIS SUMMARY IS FOR THE ENTIRE SITE, AS WELL AS ANY OFFSITE AREAS IT IS MODLED USING THE 10 YR STORM Subbasin Summary Subbasin Area Weighted Total Total Total Peak Time of ID Curve Rainfall Runoff Runoff Runoff Concentration Number Volume (ac) (in) (in) (ff3) (cfs) (days hh:mm:ss) OFF_30IN 9.96 56 5.50 1.28 46134 18.1 0 00:05:00 OFF _30IN_PRE 9.96 56 5.50 1.28 46134 18.1 0 00:05:00 OFF_BERKMAR POST 0.30 72 5.50 2.61 2839 1.3 0 00:05:00 OFF _BERKMAR_PRE 0.30 72 5.50 2.61 2839 1.3 0 00:05:00 OFF_BIO_POST 1.23 77 5.50 3.01 13453 5.9 0 00:05:00 OFF _B 10_P RE 1.23 77 5.50 3.01 13453 5.9 0 00:05:00 Post_301N_RCP 2.85 56 5.50 1.29 13325 5.2 0 00:05:00 Post_BERKMAR 1.36 68 5.50 2.27 11221 4.9 0 00:05:00 Post_Berkmar_Sheet 0.28 61 5.50 1.68 1707 0.7 0 00:05:00 Post _Bio_Out 2.01 78 5.50 3.15 22983 10.1 0 00:05:00 Post_New_Det_01 1.02 80 5.50 3.32 12293 5.4 0 00:05:00 Post_New _Det_02 0.42 94 5.50 4.76 7253 2.9 0 00:05:00 Pre _30IN_RCP 3.45 56 5.50 1.30 16306 6.4 0 00:05:00 Pre_BERKMAR 3.30 72 5.50 2.57 30810 13.5 0 00:05:00 Pre-Bio 2.60 76 5.50 2.99 28257 12.4 0 00:05:00 S_4A 0.30 68 5.50 2.28 2482 1.1 0 00:05:00 S_Inl 0.45 73 5.50 2.66 4347 1.9 0 00:05:00 S_In2 0.06 98 5.50 5.26 1145 0.4 0 00:05:00 S_In3 0.30 98 5.50 5.26 5730 2.2 0 00:05:00 S_In3A 0.34 72 5.50 2.55 3147 1.4 0 00:05:00 S_In4 0.10 98 5.50 5.26 1910 0.7 0 00:05:00 Table 1.0 Stormceptor OSR Treatment Flow Rates & Dimensions Treatme Total Sediment Lower Hydrocarbon Stormceptor OSR nt Flow Storage Capacity Chamber Storage models Rate Volume (ft) Diameter Capacity cfs al ft al Inlet OSR 065 0.63 470 8 4 115 OSR 140 1.41 952 19 6 233 OSR 250 2.50 2462 50 8 792 OSR 390 3.90 5565 98 10 1233 OSR 560 5.62 7927 141 12 1384 Series OSR 780* 7.81 1 11131 1 223 1 10 1 2430 Series OSR 1125* 1 11.24 1 15854 1 320 1 12 1 2689 * OSR model 780 and model 1125 consist of 2 chamber structures in series STORMCEPTOR SIZING STR1C1 1YR PEAK FLOW = 1.24 CFS (OSR140) STR2E 1 YR PEAK FLOW = 2.76 CFS (OSR390) STEEL PLATE (14 GAUGE) DRAINAGE AREA SUMMARY: THE DRAINAGE AREAS LISTED BELOW INCLUDE BOTH THE TOTAL 'DRAINAGE AREA' TO THE OUTFALL POINT (DITCH THAT DRAINS TO KEGLERS POND) AS WELL AS THE DISTURBED 'SITE AREA'. PRE DEVELOPED AREA A SUMMARY OF THE PRE -DEVELOPED DRAINAGE AREAS AND WEIGHTED CURVE NUMBERS IS PROVIDED ON THIS SHEET POST DEVELOPED AREA A SUMMARY OF THE POST -DEVELOPED DRAINAGE AREAS AND WEIGHTED CURVE NUMBERS IS PROVIDED ON THIS SHEET THE PEAK FLOWS LISTED BELOW ARE FOR PRE AND POST RUNOFF CONDITIONS AT THE POINT OF ANALYSIS, AS NOTED IN THE STORMWATER MANAGEMENT NARRATIVE. THE PEAK FLOW REDUCTION OCCURS DUE TO THE INSTALLED DETENTION SYSTEMS 1 YEAR, 24 HOUR STORM PRE -DEVELOPMENT SITE 12.03 CFS POST -DEVELOPMENT SITE 11.80 CFS 10 YEAR, 24 HOUR STORM PRE -DEVELOPMENT SITE 57.20 CFS POST -DEVELOPMENT SITE 54.46 CFS J VIIIF IVL INV 523.24 WEIR PLATE SECTION WEIR PLATE IN 6011 PIPE (SYSTEM 02 No Scale STEEL PLATE (14 GAUGE) J.J lJr\II IVL INV 510.12 WEIR PLATE SECTION WEIR PLATE 84" PIPE (SYSTEM 01 No Scale T)P OF STORAGE 8.24 10 YEAR WSE 527.30 1 YEAR WSE 525.29 ELEV. 523.24 T7P OF STORAGE 17.12 10 YEAR WSE 516.56 ELEV. 510.12 1 YEAR WSE 512.45 0p 0 r ;�O Q CRAIGW T. KC1TARSKI > Lic. No. 040204£507 VoT M E CDO M U N In N C: Q o > E I, I a7 E ~ LU U 3 Q '..I 3 � o U. - n LU O � UJ L M Qa _J U 00 W J - Lr; M a p r14 (7 UJ N z1 a'� O x �� LL 0 Q U) = N = U > kD Ln Q . of O 41 N It a � 00 J CD LU 1n O _ O 0 w > LU U a z O 07 > M O O a U In w Z O LU V-)� W W 0 0 W W as j W W cj� Q-1 �00 UJ O N o n o DATE 04109118 DRAWN BY 1. WILSON DESIGNED BY 1. WILSON CHECKED BY C. KOTARSKI SCALE PP U V) UJ J z O UJa J CO > Z) J <Z) z J Q wUU O w J Q oC J H� w m w J Q r^ V J LU O O J a U JOB NO. 40204 SHEET NO. C5.1 0 s= U > O In 3 0 O fl. Q T 0 N 7 0 U) a M co Q S aT 0 �o �Of o 0 a to �z ID 22 0 T � `6 0 � N a o z N 02 0. x w � 0 L m 0 s? °.3 0.0) ID N (6 0 N I= .o O U w2 (DN tr = 0 Ul U � O N E U N O.S w� .� s? U (n0 In = CoU -02 C: N M0 0 0 C:U 0_ o a) _0 L A soils B Soils C Soils D Soils Totals % of Total Forest/Open (acres) 0.00 0.00 0.00 0.00 0.00 0 Managed Turf (acres) 0.00 1.30 0.00 0.00 1.30 52 Impervious Cover (acres) 0.00 1.20 0.00 0.00 1.20 48 2.50 100 Virginia Runoff Reduction Method Worksheet Virginia Runoff Reduction Method Worksheet Virginia Runoff Reduction Method Worksheet �;J i- -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- --- --- --- --- --- --- --- -- --- -- � ... DEQ Virginia Runoff Reduction Method Re -Development Compliance Spreadsheet - Version 3.0 Site Compliance Summary Drainage Area Summary BMP Design Specifications List: 2013 Draft Stds & Specs 0 Site Summary Maximum % Reduction elopmentLoad lowl 20% CR IGW I. KO'I'ARSKI> Lic. No. 0402048507 �. Total Rainfall (in): 43 1011 2�18 Total Disturbed Acreage: 2.50 v Site Land Cover Summary (? 41 y NAL Pre-ReDevelopment Land Cover (acres) Drainage Area Compliance Summary �'���• M E CREDITS TO BE PURCHASED O N V N � C Q O > E Post-ReDevelopment Land Cover (acres) Lu ai E LU U 3 Q I" I t 3 LL O W ro,r Q U oo Z tl J Site Tv and Land Cover Nutrient Loads > 00 F a UJ (A rJ 0 41 3 X U LL I �W �LL I� 2 cz N Z = U Q O ~ Ln N O N > LU Total TP Load Reduction Required (lb/yr) 2.39 0.54 E:E] M Z Z W W 00 � CD LU 00 U U 0 0 � _ U) Ln (D j LLI LLI O � o; H 0 00 Do LU LU LU O N = a Summary Print Summary Print Summary Print U 0 O Q O *- Z O DATE Virginia Runoff Reduction Method Worksheet Virginia Runoff Reduction Method Worksheet 04/09/18 O } DRAWN BY ---------------------------------------------------------------------------------------------------- - Drainage Area A Summary Runoff Volume and CN Calculations J. WILSON 1-year storm 2-year storm 10-year storm • DESIGNED BY Land Cover Summary Target Rainfall Event (in) 0.00 0.00 0.00 J. WILSON • • CHECKED BY 1.26 • C. KOTARSKI • • SCALE BMP Selections • • �] • U M W LU Q � w LU w m a = J Z 0 Q o Q Summary Print Summary Print U LU LU J � m � J r n Q V / W NOTES: O 1. LANDCOVER LISTED IN VRRM SPREADSHEET IS BASED ON LIMITS OF DISTURBANCE 0 �J 1..1� U JOB NO. 40204 SHEET NO. C5.2 Un A soils B Soils C Soils D Soils Totals % of Total Forest/Open (acres) 0.00 0.00 0.00 0.00 0.00 0 Managed Turf (acres) 0.00 0.25 0.00 0.00 0.25 10 Impervious Cover (acres) 0.00 2.25 0.00 0.00 2.25 90 2.50 100 Final Post -Development post- Post- Adjusted Pre- (Post-ReDevelopment ReDevelopment Development ReDevelopment & New Impervious) (New Impervious) Final Post -Development Load (Post-ReDevelopment &New Impervious) Pre- ReDevelopment TN Load (Ib/yr) 35.69 22.84 Pre- FinalPost-Development Post-ReDevelopmentTP ReDevelopment TP Load per acre Load per acre TP Load per acre (Ib/acre/yr) (Ib/acre/yr) (Ib/acre/yr) 1.87 2.00 1.87 Total Runoff Volume Reduction (ft3) 0 Total TP Load Reduction Achieved (Ib/yr) 0.46 Total TN Load Reduction Achieved (Ib/yr) 0.00 Remaining Post Development TP Load 4.53 (Ib/yr) Remaining TP Load Reduction (Ib/yr) Required 1.93 A Soils B Soils C Soils D Soils Total % of Total Forest/Open (acres) 0.00 0.00 0.00 0.00 0.00 0 Managed Turf (acres) 0.00 0.25 0.00 0.00 0.25 20 Impervious Cover (acres) 0.00 1.01 0.00 0.00 1.01 80 Managed Turf Impervious BMP Treatment TP Load from Untreated TP Load TP Removed TP Remaining Downstream Treatment Practice Credit Area Cover Credit a Volume (ft ► Upstream to Practice (Ibs) (Ib/yr) (Ib/yr) to be Employed (acres) Area (acres) practices (Ibs) 14.a. Manufactured Treatment Device- Hydrodynamic 0.25 1.01 3,664.49 0.00 2.30 0.46 1.84 Total Impervious Cover Treated (acres) 1.01 Total Turf Area Treated (acres) 0.25 Total TP Load Reduction Achieved in D.A. 0.46 (Ib/yr) Total TN Load Reduction Achieved in D.A. 0.00 (Ib/yr) D.A. A D.A. B D.A. C D.A. D D.A. E Total Forest/Open (acres) 0.00 0.00 0.00 0.00 0.00 0.00 Managed Turf (acres) 0.25 0.00 0.00 0.00 0.00 0.25 Impervious Cover (acres) 1.01 0.00 0.00 0.00 0.00 1.01 Total Area (acres) 1.26 0.00 0.00 0.00 0.00 1.26 D.A. A D.A. B D.A. C D.A. D D.A. E Total TP Load Reduced (Ib/yr) 0.46 0.00 0.00 0.00 0.00 0.46 TN Load Reduced (Ib/yr) 0.00 0.00 0.00 0.00 0.00 0.00 Drainage Areas RV & CN Drainage Area A Drainage Area B Drainage Area C Drainage Area D Drainage Area E CN 91 0 0 0 0 RR (ft3) 0 0 0 0 0 1-year return period RV wo RR (ws-in) 0.00 0.00 0.00 0.00 0.00 RV w RR (ws-in) 0.00 0.00 0.00 0.00 0.00 CN adjusted 100 0 0 0 0 2-year return period RV wo RR (ws-in) 0.00 0.00 0.00 0.00 0.00 RV w RR (ws-in) 0.00 0.00 0.00 0.00 0.00 CN adjusted 100 0 0 0 0 10-year return period RV wo RR (ws-in) 0.00 0.00 0.00 0.00 0.00 RV w RR (ws-in) 0.00 0.00 0.00 0.00 0.00 CN adjusted 100 0 0 0 0 L_ ADEQUATE OU TFALL COMPUTATIONS PEAK 2-YR FLOW TO A -A- ____48E w _ �_� vi q Hydrvgraplz Report _ _" _ �-- - - VE i �C � I V V LV �-� f r tr 11�}yx.Ifje4[yenyliekxOmve:r..wi.'nLtLC+N ]Up:VIM1 Dy FuttWJk ►�=: v10.J i�il�dW. W7��7yp16 _.-+^^'�'�"��-J�~ .�----�.__-�-- ,kknn��� .. ,,.„ a l �� 46mm � _ _ '__".."" -- - -- l.� �fo �-Y'� SOIL BOUNDARY TYP' c t• F meveibped P�Oegsraye Ghannel� _ - I� V `� �� I "-`��.�` �.,• 1 •� r f f !� v Hydrngra h k +� SCS Runoff Peak [SScharge = 5i.e1 cls .•"� �, �` �. '�... .��` 1 I Storm t0gk*r1q = 2 Trme to peak I?.13 hrs a -....._.__._.__...... -� I V . V ,,.r`� Tirnr interval min Hyd. volume+ I90,01.9 CA prainaBearea = A4.39fiac cw number s" Basin Sk1pt ` DO % Hydrangc langth - 0 it '65,B TCmat3lod = t}5er Tune of Cork. [TC} = Ll7.l5SJ mkl �Y 7alat , = atr efacn = Type li h 1 f1 24 s * Storm aural = ZA hrs Shape faC:or a64 d0f; _ Q W%) 6,.OG eaav AO-00 W.na 20-0 10AG o.OD Q 2 4 IS f 16 U 14 15 18 70 22 v 26 T"(hrs) -�+ Hytl No 10 Posufavdaped Ad "to Channel Hyd No. m _ 2vow SECTION A -A CROSS SECTION Channel Report .. ..• e�peys Ed?oHm $rIrRWWre �rF�CMJ.apbO}'. is GROSS SECTION A -A Napca "nad Immrt Slav (S) = 480,00 Highlighted paplh (11) . 1.76 stops 06) = 2-W H-V81ue = 4,p3r] a toss) ArAa 00). Vei00d MIS) G�uAallvp4 VVetled Parlor iri) • 10-Ul !Coi Vkft hy: Gomm 0 A m 0 Cola) * 51,13i w Grtt cia pm, YC (e) Ttlp Width (ft) = 1. . Al EGL.M) = 2.11 [[ l aa�svo} iLa ic'vm cn n{a.uv,e UZOLQWy0% .0:.0c.s.asc IH{ V,dbCh. sdjW1%4.,0icneoaor Elev {ftT Seelf�a iupth (ft) "00 xCID 48d.70 ._. am _ 43340 4M 90 faitQ - _.... ..........._ .. ___ _... ...._ _. _. ......_............. _�. _.._ J'Qv. -1,00 4s9.00 -2 0 2 a 6 $ iH 1; 'I4 16 18 .vita iR) 5 fps Oft NOTE: SECTION A -A GEOMETRY BASED ON FIELD OBSERVATION AND MEASUREMENTS OF THE CHANNEL TOTAL DRAINAGE AREA = 49.39 AC OFFSITE HOUSES = 115,999 SF = 2.66 AC OFFSITE DRIVEWA/PARKING = 272,837 SF = 6.26 AC CN = 98 OFFSITE ROADS = 100,464 SF = 2.31 AC OFFSITE TOTAL IMPERVIOUS = 489,300 SF = 11.2J AC ONSiTE PREDEVELOPED IMPERVIOUS AREA 1.93 AC ONSITE POSTDEVELOPED IMPERVIOUS AREA = 1.76 AC OFFSITE FOREST/OPEN SPACE = 876,427 SF = 15.44 AC CN=55 ONSITE PRE/POST DEVELOPED FOREST/OPEN SPACE AREA = 0.84 AC OFFSITE MANAGED TURF = 18.55 AC CN = 61 ONSITE PREDEVELOPED MANAGED TURF = 1.40 AC - ONSITE POSTDEVELOPED MANAGED TURF = 1.57 AC PREDEVELOPED CN 13.16 AC * 98 1289.68 19.95 AC * 61 1216.9 5 16.28 AC * 55 895.4 3162,79/49.39 = 68.88 CN POSTDEVELOPED CN 12.99 AC * 98 1273.02 20.12 AC * 61 1227.32 16.28 AC * 55 895.4 3395.74/49.39 = 68.75 CN CN VALUES TAKEN FROM THE VIRGINIA RUNOFF REDUCTION METHOD FOR 8 SOILS. �,L iId ��i6. 33028 no. 6j us Cu U- ,--4 t>. 'V W � a � 04 cn i� � � q q I r w rn DOM. PROJECT NO:15.006 SHEET FROM WP0201600011 SHOWING PREVIOULSY APPROVED DRAINAGE AREA TO KEGLERS POND. PROVIDED FOR REFERENCE ONLY INDEX TITLE ��1'5 SHEET NO: 5 of 11 DATE: 2/19/16 JHo CRAIGW 3. K9FARSKT Lic. No. 0402048507 10/12/18 cg"r 107VAL M E O O M V N V; N c: > E W ~ U T 3 Q U. � o LL - w Lu L M �- co= - L'; H a p rV C7 W N A O x 0 Q (n = N = U >Lr l Q - c � o m a.-, N M d � co J O W CL O c� DATE 04109118 DRAWN BY 1. WILSON DESIGNED BY 1. WILSON CHECKED BY C. KOTARSKI SCALE 1� U r� V w J W Q U z W Lu m > Lu LL J W Qz 0 w U LL W LuJ J J Q I -I m Q J r^ Q C> V J G Lu O J Q Z I� A JOB NO. 40204 SHEET NO. C5.3 O c 0 U c 0 0 3 0 0 a n T C (6 0 D 0 0 a cu 1= C a 0 0 0 �0 o� U) �0 0 c E° � N 0- O D U zN 0 g x w� O L 0 Q� o� a 0) >� N co �N X C 0 O 0 U w2 �N (6 0 O N U 00 E U N 0 � 0Z U 0 O N ,o co U -0 2 c: M� rn o O U r-° o a) _0 rn L Section 6. Pollution Prevention Plan. (reference County Code 17-404 and State Regulation 9VAC25-880-70 part II section AA) A. Plan showing pollution activities and prevention practices (Provide a reduced I Ixl7 copy of a site plan on which all of the following activity locations are clearly marked. Keep this plan up-to-date with ongoing site changes and inspections.) Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County c 0 0 rn 0 0 Q 0 of N V Lo 0 0 0 a a 3 w U) a a z J 0- z H z w u1 a ,� \/ I / / r /�/ / / / 14 oo �%r ROCK ARMOR R /r / //i ���i/ / -> ter, _ _ _ S C RB INLET, T OP 514.35' ' - ♦ 55 \ - / \ / �// i rir/ / /r/�/ s ry I - '�/ INV. OUT=510�75 15 R I I P / / SD r / C�/Rs AIC`9 WIGRATE //-'_-- ----------- - / ,'� \ ` '�.� TOP (G TE)=513''. 8 �/ .1N510.30'1�RCP(NORTH + �� r /r / l _ _ - - / / / / / rri / // /j �l ,� , _ ♦ - .SEEM T # O I l=510.43' 5"RCP WEST // // /rr �s,�,�- -- 1B- I F R E I N (WEST) /// \ PROFILE OF STRC \ / _(/, , \ �// . J r ■ © I \ / y / / / / lr / // r /iir/ / \\� ' ♦ 4 �I V. UT=510.�' 15" RCP __-543- \\\ / /� /// �/ / '/ IP // / US STO SIGN/ \ II I II / \---- / / ' \ - - - Z- - / y0,.. _ - _ ■ �,■ STR C - \ _ �` \ \ / / \ / � � r �/ /J�/ / //err � \ ;' r/�� �' IP � � / � / � � /' MFRC7 y �' / /' ■ _ 15"RCPN q ( - " /// \ l / 71, ,\\ SQCU,BIYLETWXp\ I I II�oo L I I ¢/ \ \ / - _ _ _ ♦ v, Z W o _ \ d / h / %' \ / / / INV,,YN= / V.12 ►15 RCP M D 1 r / l V OU -519. 62' 15" R m / / / OP=510. 72' s� • / // r fir' / - I I "5 r / �\ / / FFE=543.46\\ ` / / / / / r �y ¢ // r / l I / / INV. 1N=507.56' 18"RCP (EAST FFE=543.46' ■ \\ 5 r / \u\ INV. 1N=507.30' 18" RCP (WES7 wpm \ = / FFE= O A 6 Ft U/ JER / / / r , ;� / / / y> / / \ INV. OUT=506.62 18"RCP r CWD 543.46' FFE=543.47' \ I \\ IT A �v ji-` STR A' I _ -IR. O rir r / / / / / / /// y!/ SD CURB INLET W/GRATE \ FFE=543.46 DUMPS T 1C?NT�N\I�rTC�RE -� / / / / / FFE=543.44' FFE=543.49 ■ L) / \ / / EXCAVATED DROP INLF� ( )- TOP GRA TE =510. 39 FFE=543.47' R 'D' - - / T 1 / / / / / i' / INV. OUT=507.89' 18" RCP \ \ \ FFE=543.42 \ / % / / /Qy \ , \ �/ \ r \ / / / / / / > SEDIMENT TRAP // BOTTOM ELEVATION = 529.47 / !/ ,'� r �i� ' / %/ /// / /!�/ INLET TOP = 531.47 - SD CURB INLET W/GRA7 DRAINAGE AREA = ODD fC ( )_ // / REQUIRED VOLUME: TOP GRATE-511.34' I �\ \ \ ' ' CE - / , , _ / / r r % (_ IINV. OUT=508.41' 18" RC 2 STORY / / } ' LI / / /// / / // / / X AC X 134 CY X 27 CF/CY 1087.15 CF INV. 1N=508.81' 15"RCP FFE=543.49' BLOCK & HARDI-PLANK BUILDING FFE=543.47' III I \ \ \ \/' - - - /- I r / / / % //// / / I \ 1 \ \ (CASPCA FACILITY) / / / VOLUME -PROVIDED - 1265 CF _ _ - _ _ , / /\ • 3355 BERKMAR DRIVE Jll '---t--�i 1 \ - - - - _�� ' ( / / // /1 // j ///� / I / -I / _ _ _ - I \ , // //%/ / // / // \ WASH�RACK DRAIN / d / > w / / / / // j r, TO SEDIMENT TRA FFE-543.49 / \ \ -►- -/- / /\ \� / SSF✓ CWD \ \ \ \ \ \ / FFE= FFE=543.49' l l l / l / 'G C ' '' 530.12/I TEMPORARY / FFE=529.62' FFE=543.49 I� - I TOILETS x FFE=54349' Z/� . / 1 ` \ \ _ \ ` ' CONCRET - / r \ \ ---��• / i InI 92 `- 7O \ WASHOUh/--�- / ' \ \ _ - - - - \ \\ - - - _ _ _ _ �\ ./ / r / / / T _ / \ I ' • �\ SE IT Eiw R / SD CURB INLET W/GRATE OfI Fr2P!/IISC I P TOP (GRATE)=509.20' _ _ u _- _ \8,. INV. OUT=506.25' 18 RCP J GCA IWIII\ 2 � /' / // /' / / , // //�// E. I - I_w _ II , \ / / /rr / / ' r , \ , _ , r / / / / SD CURB INLET W/GRATE / / r 'S,,'O - - - - I \ 11- \ f r/r r /r / \ r r �, �l r TOP (GRATE)=508.60 / / , - - - / - - - - \ ' _ \ \ \ I I \ ♦' / / // // i r r cT , / r / INV. IN=504.00' 18" RCP NORTH ♦ - - - - - - - - - , - - 1 \ I I \ \ / , / • / \ INV. 1N=504.33' 18" RCP WEST `--\` ----r - \ \ UN ER RC&U DD TN ON \ -� \ r r / / I / _ (WEST) \ / ----- _--_-------- APRO PE Rl INAL / / / / I ®S�TRF- I . , %� / \ rr /% / / j I / INV.OUT-504.0218 RCP S TR 'G' Ci CI IL Sl E PL N s - - - _ - - - - _ �' IGD/ % -%\ r // / / / SD CURB INLET W/GRATE \ \ \ \ \ \ \ N6'��8, �_ _ _,'_-- _- - -----� - _// _ I �\ TOP (GRATE)-509.44 - _ ¢�L - �� _ _ _ -- ---- - _ yr '" - /�, - - - - \ r r / %// / �?',QC, I // INV. OUT=506.26 18"RCP -- - / - _�_ SD CURB INLET W/GRATE D / - - _ -� _ - - ' - -d - - - - - ` - _ - ' ' SOP-5f4 3 - - I / / / / I TOP GR,4TE-509.06' SSF _ i - --___� __ -_520� \ �\ _= J'j! /f _ _ '/ ( )- \ INV. IN=502.76' 18" RCP (NORTH) IN IN=502.9518 RCP(WEST) \\\ \ \\ \\ \ \ \\ \\� - �■ - __s \_ ___-_- 518517 INV. OUT=502.7618 RCP \ _-------�■ _ 5' / SEESHEET####FO PROFILE OF STRC \ �5, 514 IP y It ,2B-2� F06t' SI / 1 ANIT f� l ID l® c� �2 Q� ---------- - - - - -- EXCAVATEDDRO-PINLET - �515 515514- - \ \_ j �, / ♦ ` / M 1 \ \ \ \ \ \ \ \ \ \\ \ _ _ SEDIMENT TRAP _ � _ _ +, / F BOTTOM ELEVATION = 513.42 - ' _ _ I Ir / / 1 "� ----\ \ \`\\ \`\ \ \ \P��O�C\LbCANO \ \\\--------- INLET TOP =515.42 ---___ 0 �- ♦ / I I I / / �� opt \ ` - - - - \ \ \` \ • \ INTERMIT7�EIV S7�REA \ \ \ \ \ \\\ I \ DRAINAGE AREA = 1.12 AC I / X�� i' ♦ / / ♦ r 1 �' ✓ ^41 )c � �� \ 2 \ \ \ \ \\ REQUIRED VOLUME: I ' II / / / j / / l ----- \ \ \ \ \ \ S \ \ \ \ \ \ \ \ \ \ \\ 1 / / / / / \ V \I ` \` _ \ It ' r / 2 NOTE: PPP TO BE AMENDMENT BY CONTRACTOR X �C X 134 CY X 27(CF/CY,� 4055 CF I �/ / � _ N A \ \ S \ \ \ \ \\\\ \ \\� VOLUME PROVIDED= 165 CF - \ I I `\ / k SF / // \ O Q \ \ T41F,45-88` \ \ \ \ \ `� CONCRETE / AS NECESSARY DURING CONSTRUCTION -� =--- - \ \ \ \ \ \ \ \ T('EA\L$EMARLL,SC�E�TYIGQR-TIPE\ \ \ _ _ _ _ _ - \ \\` / \_ __ _--- � \ FLUME PREVEN�TlC?I1��iF �f�UEI�TY�}QANIN�,gL� \ \ \ \ \\ � \\ � _ \ � -� \ \\ \ \ I I Ns / /co \ \ \ \ \ \ \ \ ' \ ` � \ \ RISER 2.5 x 2 5 GRATE 2�• � / �k� \ \ \ \ \ - \ \ \ \ \ su' ` \` \ ` �6���14, PG 61 \ \ \ \ \ \ \ \ \ \\ \ _ _ \ I I / ( ) \ o � _ \ \ \ \ \ I I TOP=512 70 / \ \ \ \ \ \�O�AILL� R�6 \ \ \ \ \ \ \ \ \\ \ \ I I 1 INV. IN=510.40 6 PLASTIC (SW) \ \ \ \ _ \ \ \ \ \ \ • \ �' C \ \ \ \ \ \ ` \ \ \ ` \ \ 1 /NV. 1N=509.40' 6" PLASTIC (NE) I I I Cc� \ / I / \\ \ \ 0\`\ `\\ \ \ \ \\ \ `� \\\ \ \`\`` \ \\\ \ \ \ \ \ \ \ / _\\ \ \\ \_ TMP 45-109C3 \ APPROX. 44' FUTURE R/W. \ \ \ \ \ ` - \ \ \ \ \ \ \ `Saiv^ \ \ \ \ \ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ / \ ` \ \I)) / / INV OUT=509.01 ' 15" CPP I I I \� I /\ RESERVED FOR FUTURE DEDICATION FOR PUBLIC US UPON EARNER, DAMES & ROXJNE IN,II I \ DEMAND OF THE COUNTY. \ \ \ \ \ \ \ \ \ \ \ \ \ / \\ \\ \ r I/ //// n DB. 4826, PG. 608 It / \/ � / O \ \ \ �� \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ I \ / I1 \ \ \ \ CIP � ZONED: C-1 I � 11 I I \ IN, MHD TOP=514.14 --� INV. IN=498.89' 30" RCP -- SFR°n.��nm�F \ \, EROSION CONTROL LEGEND VESCH # LIMITS OF CLEARING AND GRADING - DRAINAGE DIVIDE CONSTRUCTION ENTRANCE 3.02 SILT FENCE 3.05 SUPER SILT FENCE 3.05 co INLET PROTECTION & o0 EXCAVATED DROP INLET 3.07 Q lz CULVERT INLET PROTECTION 3.08 - SCALE 1 "=30' DIVERSION DIKE 3.12 0 30' 60' M E O O V N V; N c: > E w E ~ U 3 Q U. 3 0 LL o w O co ,1 cl� yd L M Q� U o0 W J - Lr; W cc::N z� a'M o x C) � w Ln _ N = U j Ln O rn41 M co J CD Lu w a 0 DATE 04109118 DRAWN BY J. WILSON DESIGNED BY J. WILSON CHECKED BY C. PENNETTI SCALE U C� W W � J Q z z Q W Q a co > Jrz Qz0 O Wwz J J J Q W Lu I -I ° j W > a V W z 0 0 J J J 0 i U 30B NO. 40204 SHEET NO. PPPl 0 c U C 0 0 0 0 a Q T `o a N 7 0 a c co co 0_ 0 0 c N d �0 a � o z �0 0 c E o a a) c o � N 0- U D 0= �3 zN 0 X 0 L 0 0 o .3 0 ID E' 2! _2 N Fq 7N X c: 0 0 � U w 2 m (6 0 o 0 Ea 0 � U � a0 �a U N 0.2 coU a 2 cN M� N 0 � U 0_ o Ua _E L_ 0 0 0 a a w 0 N v in 0 0 m 0 a 3 w W a a z J 0- z O H z w u1 o' a l`Ulv DB. 2014, PG. 024 ' \ / l / / �� TREE AONS9 ATION AREA I— � — ZONED: R-6aft 0.2 AC jiT�7TAL �0.78�C\)\ 1 r ♦ /� / / r / / r �/x —� / `� I / // / Air* 11 -f - / 14 ol _ _ r HYDRANT IP 77/ 77 / / / / �/ / �/ / //��/i////�// ;'� \ / — SSF 1000, All---- '�` / __/ 0.33 /'///// /// 5 \ / I I / / _.-543- \\\\\ // // /// ////// //l �� IP /�' \� III �I I /I)/ USSTOF'SIGN/ ' \----N. _ / �550/ — / / , — — / — ��■ ` y ' ` /' ol, / / // ' 1C c (51 vw 510 / 1 I 1641 �VDVt1 - - I 44Ul / -------/ l\_' / 41 \ \ X , 1 2/ 10 IP 5¢Tr 0 — / \ / \ _ _ ` 1 \\ \ \ / / / ■ ■ / i Y\ , \ 7 /� / / ISfR //r\ \_ _---- _ I 1 _ 5 0.0` 85 / \ \ L / \ _-- _ \\ \_- _--_ 535 / / / I' \1C3 / 529 41 IP 41 0:70 IN _52 _, �9--- =S 1\ \ \ \\ \ 'S / // /'• - - - S - _ 2�\ �S_\__ 2F IAL _ _ ----- - / 530--- _ \ /% J��'. 15— SF - _ _ _ _ — — 525. 520 5 ---- - -- -- - _ 524 52 \ \ 3 _ 552322 - la \`\ \ \ \ \ \ ` \ \ \\\ `�� — — — —— `— ___—� _ \ \ \ \ \ \ \\ \ \ \ \ F \ N AP)\\ \\\ -_-_� \ -- 8 pl/ ��� r I l DO A M N\�Si�REA�I \ \-------_ ----(gd �.` \`\ \\ \ \ `INT�R1601TTE \ \\ / 40 G O `\\ \`\ S \ \\\\\ `\\\ ` \ \ \ \\\--------- ---- - ,'c/ / � / \ 44/ �O rij NOTE: PPP TO BE AMENDMENT BY CONTRACTOR \\ \ \ 2 \ \ \ \ \\ \ \\ — — — _ _ „ I I / / / / / / \ \\ \\ \ \ \�s \ \ \ \ \ \ \ ` \ \ \ \\\\ 1 \� - - - - _ _ I 1 \ / / / / VO QO AS NECESSARY DURING CONSTRUCTION — \ \ \ \ \ \ \ \ \ S \ \ — — — I \ / \ \ \ ` \ \ \ \ \ \ \\\ / \ I \ / X \ G Q \ N N \ ` \ \ \ \ \ `Tt,) A\L$E-A4ARLE.SO�E�TY)uQRTPE\ \ ` \ \ \ `�\ � \` \ / \�= _ _ \ \` \ _ \\ \ ` \ \ ` ` \�REl N1T/^A/%%r bI�UEI�T �QANIN%fLLS� \ ` \ \ \\\ \ ` \ -` \\ - \ I 1 I /U �� S �k / / \ Uj _ \ \ \` _ \ \ I I \\\\\\\\\/ \\ \\`\`\ \` \\`N \\\SO\\\ \\\@�.4��/4�)98 \\ \N\\\\\ 662jSp� _� \ \ _ \ \ \ \ O\ \ \ \ \ \ \ \ \ \ \\ \\ \ \ \ \ \ \ \ \ \ \ \ \` \ \ \ ` \ \ \ ` \ \ ` \ \ \ \ \\ \ \ \ B ` \ \ \ \ \ \ \ \ \ ` \ ` \ \ \ \ ` ` \ \ ` \ \ \ \ \ \ \ ` \ \ \ ) / _ \\ ` V \ ` _ �� TMP 45-109C3 \ \ / \ ' APPROX. 44' FUTURE R/W. \ \ \ \ \ _ \ _ \ \ \ \ \ \ \ \ Sii \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ \ \ I / l \ \ ` \ — \ \ \ \ \ \ / EARNER, DAMES & ROX�I NE I 1 /\ RESERVED FOR FUTURE DEDICATION FOR PUBLIC US UPON \ \ ` \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ _ \ \ // I / \ \ ` N6 0 \ \ \ \ \ \ \ ` \ ` `\ \ \ \ ` \ \ \ ` \ \ \ \ \ \ I ! / / \ \ DEMAND OF THE COUNTY \ \ \ \ \ 675, ` \ ` ` ` \\ \ \ \ \ \\ \ \ \ / \\\\ \ : I//�llr DB. 4826, PG. 608 / \l O \ \ \ \ \ \ \ \ \ \ \ \\\\\ \ \\ ` \ \ \ \ \I cIP ` / / I / \ \ \ \ \ \ \ ` \ \ \ \ \ \ l / h / ZONED: C-1 \ ` \ \ \ 68 \ ` �— \ \ \ \ \ S ` ` \ \ \ ` \ \ \ \ \ \ \\ \ \ ` ` \ \ \ \ \ 1 1 \ \� �/� / �/ I \ \ \ \ \ \ 766 \ \ \ ` \ �p \ \ \ \ \ \ I \ 1p' l / \ /' \ \ ` ` \ \ \ \ EROSION CONTROL LEGEND rAFB) C VESCH # LIMITS OF CLEARING AND GRADING - DRAINAGE DIVIDE - SILT FENCE 3.05 SUPER SILT FENCE 3.05 INLET PROTECTION & 3.07 EXCAVATED DROP INLET DRAINAGE AREA LABEL: A - AREA SIZE (AC.) B -CN C - D.A. IDENTIFICATION C'M 00 Q z SCALE 1 "=30' NOR 0 30' 60' M E O p ul V N V; N c: >E w E ~ Lu U 3 Q U. 3 0 LL o w O co ,1 0� yd = M Q< w U 00 W = - Lr; M W 00 N v O U) x C) LL = N N = U > LnLf O N M 00 J �.o �--- 0 0 H 0 w w U Q z 0 0 z 0 a U V) w 0 z 0 U) w w a 0 DATE 04109118 DRAWN BY 1. WILSON DESIGNED BY 1. WILSON CHECKED BY C. PENNETTI SCALE U V 1 w z J Q Ce J � z W 0 J � 'W zI ` O > LUJ LL J '—'mz J (n a0 V / H� Lu D J J O 0 J U JOB NO. 40204 SHEET NO. PPP2 0 c 7 U 0 0 0 O Q T C `o a) N 0 c s a co co 0- 0 0 m 0 3 c L B. sources of rotlutants, locations, ana urevention practices Pollutant, or Pollutant Prevention Practices, Generating Activity Location on site Control Measures C. Sources of Pollutants continued. Common activities and minimum control and prevention practices Pollutant, or Pollutant Location on site Prevention Practices, Generating Activity Control Measures Follow Erosion and Sediment Control Clearing, grading, excavating, and un- Land disturbance area Plan. Dispose of clearing debris at stabilized areas acceptable disposal sites. Seed and mulch, or sod within 7 days of land clearing Cover storm drain inlets and use drip pans Paving operations Roads and driveways and absorbent/oil dry for all paving machines to limit leaks ands ills Direct concrete wash water into a leak - Concrete washout and Current location and detail shown on proof container or leak -proof settling basin cement waste plan that is designed so that no overflows can occur Enclose or cover material storage areas. Mix paint indoors in a containment area or Structure construction, stucco, Structures in a flat unpaved area. Prevent the painting, and cleaning discharge of soaps, solvents, detergents and wash water, paint, form release oils and curing com ounds. Water shall be filtered, settled or similarly Dewatering operations Dewatering sites shown on plan treated prior to discharge as shown on plan. Designated areas for material delivery and Material delivery and storage Designated area shown on plan storage. Placed near construction entrances, away from waterways and drainage paths Material use during building process Building areas Follow manufacturer's instructions. MSDS s attached. Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Pollutant, or Pollutant Location on site Prevention Practices, Generating Activity Control Measures Waste collection area will not receive a substantial amount of runoff from upland areas and does not drain directly to a Current designated container areas on waterway. Containers have lids covered Solid waste disposal plan before periods of rain, or are in a covered area. Scheduled collection to prevent overfilling. MATERIALS NOT TO BE BURIED ON -SITE Convenient and well -maintained portable sanitary facilities will be provided, and Sanitary waste Current locations shown on plan located away from waterways or inlets. Such facilities shall be regularly maintained. Apply fertilizers in accordance with Landscaping operations Landscape areas shown on plan manufacturer's recommendations and not during rainfall events To be treated in a sediment basin or better control as specified on plan. Minimize Wash Waters Wash areas shown on plan the discharge of pollutants from equipment and vehicle washing Vehicle and equipment washing Designated areas and details shown on Provide containment and filtering for all plan wash waters per the plan Minimization of exposure to precipitation and stormwater. Minimize the exposure of building materials, building products, construction wastes, trash, landscape materials, fertilizers, pesticides, herbicides, detergents, sanitary waste, and other materials present on the site to precipitation and to stormwater. (Identify all non-stormwater discharges to occur on your site. Keep this plan up-to-date with ongoing site changes and inspections. See CGP, 9VAC25-880-70 section E for examples of non-stormwater discharges.) D. Non-stormwater d Discharge Dust Control Water Pollutants or Pollutant Constituents Sediment Location on Site As required inside LOD Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County E. Persons responsible for pollution prevention practices (Provide the names and contact information for all persons responsible for prevention practices as listed above.) F. Response and reporting practices Minimize discharges from spills and leaks. Minimize the discharge of pollutants from spills and leaks and implement chemical spill and leak prevention and response procedures as follows. Respond to all spills, leaks and discharges as follows; Materials and equipment necessary for oil or chemical spill cleanup will be kept in the temporary material storage trailers onsite. Equipment will include, but not be limited to, brooms, dustpans, mops, rags, gloves, goggles, kitty litter, sand, saw dust, and plastic and metal trash containers. All oil or other chemical spills will be cleaned up immediately upon discovery. Identify and stop source of discharge. Use absorptive materials to soak up as much chemical as possible. Place all contaminated material in trash containers for disposal. Report all spills, leaks and discharges as follows; Reports will be made to the following: Virginia Department of Emergency Management Emergency Operations Center (EOC) Phone: (800) 468-8892 Spills large enough to reach the storm sewers will be reported to the National Response Center at 1-800-424-8802. (Provide detailed response and reporting practices according to 9VAC25-880-70, Part II, section AA.e.) Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County G. Pollution Prevention Awareness (Describe training and procedures to provide awareness and compliance for all measures in this document; waste management, wash waters, prevention measures, etc.) The registered land disturber shall oversee all construction activities to implement and maintain pollution prevention measures. As such training and procedures shall be provided by the contractor for each worker on site before they begin land disturbing activities. Pollution Prevention Training shall include but is not limited to; Training on the proper storage and handling of hazardous solvent and chemicals, per the manufacturers recommendation. Training on proper fuel storage and the use of fuel containment facilities located on site. Training on the proper way to handle concrete/mortar washout areas, and the disposal of the waste water from these activities. Additionally training shall be provided on the proper way to dispose of all debris related to the construction activity (hazardous and non -hazardous materials). This list should not be deemed all-inclusive and if the contractor or registered land disturber deems that additional pollution prevention practices are required training shall be provided for them. Training on implementation of erosion and sediment control devices/procedures must be provided by registered land disturber each time a new E&SC procedure is constructed. Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 7. Discharges to impaired waters, surface waters within an applicable TMDL wasteload allocation, and exceptional waters. (Provide detailed measures for any applicable TMDL) 1. Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site. 2. Nutrients shall be applied in accordance with manufacturer's recommendations or an approved nutrient management plan and shall not be applied during rainfall events. 3. Inspections shall be conducted at a frequency of (i) at least once every four business days or (ii) at least once every five business days and no later than 48 hours following a measurable storm event. In the event that a measurable storm event occurs when there are more than 48 hours between business days, the inspection shall be conducted on the next business day. 4. Representative inspections used by utility line installation, pipeline construction, or other similar linear construction activities shall inspect all outfalls discharging to surface waters identified as impaired or for which a TMDL wasteload allocation has been established and approved prior to the term of this general permit. Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 8. Qualified personnel The following personnel are responsible for inspections; (Provide the name, telephone number, and qualifications of the qualified personnel conducting inspections.) Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 9. Signed Certification (Provide certification according to 9VAC25-870-370. For purposes of plan review and approvals, this certification should be the owner of the property, the same signature as appears on the bonds and applications. Another operator can be designated on the delegation of authority form to follow.) CERTIFICATION "I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations." Owner/Operator Name: Company: Title: Signature: Date: Angie Gunter Albemarle Societv for the Prevention of Crueltv to Animals Issued— 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 10. Delegation of authority. (Provide the persons or positions with authority to sign inspection reports or to modify the stormwater pollution prevention plan. A formal, signed delegation of authority is needed.) Delegation of Authority I, (name), hereby designate the person or specifically described position below to be a duly authorized representative for the purpose of overseeing compliance with environmental requirements, including the Construction General Permit, at the construction site. The designee is authorized to sign any reports, stormwater pollution prevention plans and all other documents required by the permit. (name of person or position) (company) (address) (city, state, zip) (phone) By signing this authorization, I confirm that I meet the requirements to make such a designation as set forth in the Construction General Permit (CGP), and that the designee above meets the definition of a "duly authorized representative". Operator Name: Company: Title: Signature: Date: Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County Section 11. General permit copy (Provide a copy of the construction general permit, 9VAC25-880) Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County COMMONWEALTH of VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY General Permit No.: VAR10 Effective Date: July 1, 2014 Expiration Date: June 30, 2019 GENERAL VPDES PERMIT FOR DISCHARGES OF STORMWATER FROM CONSTRUCTION ACTIVITIES AUTHORIZATION TO DISCHARGE UNDER THE VIRGINIA STORMWATER MANAGEMENT PROGRAM AND THE VIRGINIA STORMWATER MANAGEMENT ACT In compliance with the provisions of the Clean Water Act, as amended, and pursuant to the Virginia Stormwater Management Act and regulations adopted pursuant thereto, operators of construction activities are authorized to discharge to surface waters within the boundaries of the Commonwealth of Virginia, except those specifically named in State Water Control Board regulations that prohibit such discharges. The authorized discharge shall be in accordance with this cover page, Part I - Discharge Authorization and Special Conditions, Part 11 - Stormwater Pollution Prevention Plan, and Part III - Conditions Applicable to All VPDES Permits as set forth herein. General Permit No.: VAR10 Page 1 of 21 PART I DISCHARGE AUTHORIZATION AND SPECIAL CONDITIONS A. Coverage under this general permit. 1. During the period beginning with the date of coverage under this general permit and lasting until the general permit's expiration date, the operator is authorized to discharge stormwater from construction activities. 2. This general permit also authorizes stormwater discharges from support activities (e.g., concrete or asphalt batch plants, equipment staging yards, material storage areas, excavated material disposal areas, borrow areas) located on -site or off -site provided that: a. The support activity is directly related to the construction activity that is required to have general permit coverage for discharges of stormwater from construction activities; b. The support activity is not a commercial operation, nor does it serve multiple unrelated construction activities by different operators; c. The support activity does not operate beyond the completion of the last construction activity it supports; d. The support activity is identified in the registration statement at the time of general permit coverage; e. Appropriate control measures are identified in a stormwater pollution prevention plan and implemented to address the discharges from the support activity areas; and f. All applicable state, federal, and local approvals are obtained for the support activity. B. Limitations on coverage. 1. Post -construction discharges. This general permit does not authorize stormwater discharges that originate from the site after construction activities have been completed and the site, including any support activity sites covered under the general permit registration, has undergone final stabilization. Post -construction industrial stormwater discharges may need to be covered by a separate VPDES permit. 2. Discharges mixed with nonstormwater. This general permit does not authorize discharges that are mixed with sources of nonstormwater, other than those discharges that are identified in Part I E (Authorized nonstormwater discharges) and are in compliance with this general permit. 3. Discharges covered by another state permit. This general permit does not authorize discharges of stormwater from construction activities that have been covered under an individual permit or required to obtain coverage under an alternative general permit. 4. Impaired waters and TMDL limitation. Discharges of stormwater from construction activities to surface waters identified as impaired in the 2012 § 305(b)/303(d) Water Quality Assessment Integrated Report or for which a TMDL wasteload allocation has been established and approved prior to the term of this general permit for (i) sediment or a sediment -related parameter (i.e., total suspended solids or turbidity) or (ii) nutrients (i.e., nitrogen or phosphorus) are not eligible for coverage under this general permit unless the operator develops, implements, and maintains a SWPPP that minimizes the pollutants of concern and, when applicable, is consistent with the assumptions and requirements of the approved TMDL wasteload allocations. In addition, the operator shall implement the following items: General Permit No.: VAR10 Page 2 of 21 a. The impaired water(s), approved TMDL(s), and pollutant(s) of concern, when applicable, shall be identified in the SWPPP; b. Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site; c. Nutrients shall be applied in accordance with manufacturer's recommendations or an approved nutrient management plan and shall not be applied during rainfall events; and d. The applicable SWPPP inspection requirements specified in Part II F 2 shall be amended as follows: (1) Inspections shall be conducted at a frequency of (i) at least once every four business days or (ii) at least once every five business days and no later than 48 hours following a measurable storm event. In the event that a measurable storm event occurs when there are more than 48 hours between business days, the inspection shall be conducted on the next business day; and (2) Representative inspections used by utility line installation, pipeline construction, or other similar linear construction activities shall inspect all outfalls discharging to surface waters identified as impaired or for which a TMDL wasteload allocation has been established and approved prior to the term of this general permit. 5. Exceptional waters limitation. Discharges of stormwater from construction activities not previously covered under the general permit issued in 2009 to exceptional waters identified in 9VAC25-260-30 A 3 c are not eligible for coverage under this general permit unless the operator implements the following: a. The exceptional water(s) shall be identified in the SWPPP; b. Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site; c. Nutrients shall be applied in accordance with manufacturer's recommendations or an approved nutrient management plan and shall not be applied during rainfall events; and d. The applicable SWPPP inspection requirements specified in Part II F 2 shall be amended as follows: (1) Inspections shall be conducted at a frequency of (i) at least once every four business days or (ii) at least once every five business days and no later than 48 hours following a measurable storm event. In the event that a measurable storm event occurs when there are more than 48 hours between business days, the inspection shall be conducted on the next business day; and (2) Representative inspections used by utility line installation, pipeline construction, or other similar linear construction activities shall inspect all outfalls discharging to exceptional waters. 6. There shall be no discharge of floating solids or visible foam in other than trace amounts. C. Commingled discharges. Discharges authorized by this general permit may be commingled with other sources of stormwater that are not required to be covered under a state permit, so long as the commingled discharge is in compliance with this general permit. Discharges authorized by a separate state or VPDES permit may be commingled with discharges authorized by this general permit so long as all such discharges comply with all applicable state and VPDES permit requirements. General Permit No.: VAR10 Page 3 of 21 D. Prohibition of nonstormwater discharges. Except as provided in Parts I A 2, 1 C, and I E, all discharges covered by this general permit shall be composed entirely of stormwater associated with construction activities. All other discharges including the following are prohibited: 1. Wastewater from washout of concrete; 2. Wastewater from the washout and cleanout of stucco, paint, form release oils, curing compounds, and other construction materials; 3. Fuels, oils, or other pollutants used in vehicle and equipment operation and maintenance; 4. Oils, toxic substances, or hazardous substances from spills or other releases; and 5. Soaps, solvents, or detergents used in equipment and vehicle washing. E. Authorized nonstormwater discharges. The following nonstormwater discharges from construction activities are authorized by this general permit when discharged in compliance with this general permit: 1. Discharges from firefighting activities; 2. Fire hydrant flushings; 3. Waters used to wash vehicles or equipment where soaps, solvents, or detergents have not been used and the wash water has been filtered, settled, or similarly treated prior to discharge; 4. Water used to control dust that has been filtered, settled, or similarly treated prior to discharge; 5. Potable water sources, including uncontaminated waterline flushings; 6. Routine external building wash down where soaps, solvents or detergents have not been used and the wash water has been filtered, settled, or similarly treated prior to discharge; 7. Pavement wash waters where spills or leaks of toxic or hazardous materials have not occurred (or where all spilled or leaked material has been removed prior to washing); where soaps, solvents, or detergents have not been used; and where the wash water has been filtered, settled, or similarly treated prior to discharge; 8. Uncontaminated air conditioning or compressor condensate; 9. Uncontaminated ground water or spring water; 10. Foundation or footing drains where flows are not contaminated with process materials such as solvents; 11. Uncontaminated excavation dewatering, including dewatering of trenches and excavations that have been filtered, settled, or similarly treated prior to discharge; and 12. Landscape irrigation. F. Termination of general permit coverage. 1. The operator of the construction activity shall submit a notice of termination in accordance with 9VAC25-880-60 to the VSMP authority after one or more of the following conditions have been met: General Permit No.: VAR10 Page 4 of 21 a. Necessary permanent control measures included in the SWPPP for the site are in place and functioning effectively and final stabilization has been achieved on all portions of the site for which the operator is responsible. When applicable, long term responsibility and maintenance requirements shall be recorded in the local land records prior to the submission of a notice of termination; b. Another operator has assumed control over all areas of the site that have not been finally stabilized and obtained coverage for the ongoing discharge; c. Coverage under an alternative VPDES or state permit has been obtained; or d. For residential construction only, temporary soil stabilization has been completed and the residence has been transferred to the homeowner. 2. The notice of termination should be submitted no later than 30 days after one of the above conditions in subdivision 1 of this subsection is met. Authorization to discharge terminates at midnight on the date that the notice of termination is submitted for the conditions set forth in subdivisions 1 b through 1 d of this subsection. Termination of authorizations to discharge for the conditions set forth in subdivision 1 a of this subsection shall be effective upon notification from the department that the provisions of subdivision 1 a of this subsection have been met or 60 days after submittal of the notice of termination, whichever occurs first. 3. The notice of termination shall be signed in accordance with Part III K of this general permit. G. Water quality protection. 1. The operator must select, install, implement and maintain control measures as identified in the SWPPP at the construction site that minimize pollutants in the discharge as necessary to ensure that the operator's discharge does not cause or contribute to an excursion above any applicable water quality standard. 2. If it is determined by the department that the operator's discharges are causing, have reasonable potential to cause, or are contributing to an excursion above any applicable water quality standard, the department, in consultation with the VSMP authority, may take appropriate enforcement action and require the operator to: a. Modify or implement additional control measures in accordance with Part II B to adequately address the identified water quality concerns; b. Submit valid and verifiable data and information that are representative of ambient conditions and indicate that the receiving water is attaining water quality standards; or c. Submit an individual permit application in accordance with 9VAC25-870-410 B 3. All written responses required under this chapter must include a signed certification consistent with Part III K. General Permit No.: VAR10 Page 5 of 21 PART II STORMWATER POLLUTION PREVENTION PLAN A stormwater pollution prevention plan (SWPPP) shall be developed prior to the submission of a registration statement and implemented for the construction activity, including any support activity, covered by this general permit. SWPPPs shall be prepared in accordance with good engineering practices. Construction activities that are part of a larger common plan of development or sale and disturb less than one acre may utilize a SWPPP template provided by the department and need not provide a separate stormwater management plan if one has been prepared and implemented for the larger common plan of development or sale. The SWPPP requirements of this general permit may be fulfilled by incorporating by reference other plans such as a spill prevention control and countermeasure (SPCC) plan developed for the site under § 311 of the federal Clean Water Act or best management practices (BMP) programs otherwise required for the facility provided that the incorporated plan meets or exceeds the SWPPP requirements of Part II A. All plans incorporated by reference into the SWPPP become enforceable under this general permit. If a plan incorporated by reference does not contain all of the required elements of the SWPPP, the operator must develop the missing elements and include them in the SWPPP. Any operator that was authorized to discharge under the general permit issued in 2009, and that intends to continue coverage under this general permit, shall update its stormwater pollution prevention plan to comply with the requirements of this general permit no later than 60 days after the date of coverage under this general permit. A. Stormwater pollution prevention plan contents. The SWPPP shall include the following items: 1. General information. a. A signed copy of the registration statement, if required, for coverage under the general VPDES permit for discharges of stormwater from construction activities; b. Upon receipt, a copy of the notice of coverage under the general VPDES permit for discharges of stormwater from construction activities (i.e., notice of coverage letter); c. Upon receipt, a copy of the general VPDES permit for discharges of stormwater from construction activities; d. A narrative description of the nature of the construction activity, including the function of the project (e.g., low density residential, shopping mall, highway, etc.); e. A legible site plan identifying: (1) Directions of stormwater flow and approximate slopes anticipated after major grading activities; (2) Limits of land disturbance including steep slopes and natural buffers around surface waters that will not be disturbed; (3) Locations of major structural and nonstructural control measures, including sediment basins and traps, perimeter dikes, sediment barriers, and other measures intended to filter, settle, or similarly treat sediment, that will be installed between disturbed areas and the undisturbed vegetated areas in order to increase sediment removal and maximize stormwater infiltration; (4) Locations of surface waters; General Permit No.: VAR10 Page 6 of 21 (5) Locations where concentrated stormwater is discharged; (6) Locations of support activities, when applicable and when required by the VSMP authority, including but not limited to (i) areas where equipment and vehicle washing, wheel wash water, and other wash water is to occur; (ii) storage areas for chemicals such as acids, fuels, fertilizers, and other lawn care chemicals; (iii) concrete wash out areas; (iv) vehicle fueling and maintenance areas; (v) sanitary waste facilities, including those temporarily placed on the construction site; and (vi) construction waste storage; and (7) When applicable, the location of the on -site rain gauge or the methodology established in consultation with the VSMP authority used to identify measurable storm events for inspection purposes. 2. Erosion and sediment control plan. a. An erosion and sediment control plan approved by the VESCP authority as authorized under the Erosion and Sediment Control Regulations (9VAC25-840), an "agreement in lieu of a plan" as defined in 9VAC25-840-10 from the VESCP authority, or an erosion and sediment control plan prepared in accordance with annual standards and specifications approved by the department. Any operator proposing a new stormwater discharge from construction activities that is not required to obtain erosion and sediment control plan approval from a VESCP authority or does not adopt department -approved annual standards and specifications shall submit the erosion and sediment control plan to the department for review and approval. b. All erosion and sediment control plans shall include a statement describing the maintenance responsibilities required for the erosion and sediment controls used. c. A properly implemented approved erosion and sediment control plan, "agreement in lieu of a plan," or erosion and sediment control plan prepared in accordance with department -approved annual standards and specifications, adequately: (1) Controls the volume and velocity of stormwater runoff within the site to minimize soil erosion; (2) Controls stormwater discharges, including peak flow rates and total stormwater volume, to minimize erosion at outlets and to minimize downstream channel and stream bank erosion; (3) Minimizes the amount of soil exposed during the construction activity; (4) Minimizes the disturbance of steep slopes; (5) Minimizes sediment discharges from the site in a manner that addresses (i) the amount, frequency, intensity, and duration of precipitation; (ii) the nature of resulting stormwater runoff; and (iii) soil characteristics, including the range of soil particle sizes present on the site; (6) Provides and maintains natural buffers around surface waters, directs stormwater to vegetated areas to increase sediment removal, and maximizes stormwater infiltration, unless infeasible; (7) Minimizes soil compaction and, unless infeasible, preserves topsoil; (8) Ensures that stabilization of disturbed areas will be initiated immediately whenever any clearing, grading, excavating, or other land -disturbing activities have permanently ceased on any portion of the site, or temporarily ceased on any portion of the site and will not resume for a period exceeding 14 days; and General Permit No.: VAR10 Page 7 of 21 (9) Utilizes outlet structures that withdraw stormwater from the surface (i.e., above the permanent pool or wet storage water surface elevation), unless infeasible, when discharging from sediment basins or sediment traps. 3. Stormwater management plan. a. New construction activities. A stormwater management plan approved by the VSMP authority as authorized under the Virginia Stormwater Management Program (VSMP) Regulation (9VAC25- 870), or an "agreement in lieu of a stormwater management plan" as defined in 9VAC25-870-10 from the VSMP authority, or a stormwater management plan prepared in accordance with annual standards and specifications approved by the department. Any operator proposing a new stormwater discharge from construction activities that is not required to obtain stormwater management plan approval from a VSMP authority or does not adopt department -approved annual standards and specifications shall submit the stormwater management plan to the department for review and approval. b. Existing construction activities. Any operator that was authorized to discharge under the general permit issued in 2009, and that intends to continue coverage under this general permit, shall ensure compliance with the requirements of 9VAC25-870-93 through 9VAC25-870-99 of the VSMP Regulation, including but not limited to the water quality and quantity requirements. The SWPPP shall include a description of, and all necessary calculations supporting, all post - construction stormwater management measures that will be installed prior to the completion of the construction process to control pollutants in stormwater discharges after construction operations have been completed. Structural measures should be placed on upland soils to the degree possible. Such measures must be designed and installed in accordance with applicable VESCP authority, VSMP authority, state, and federal requirements, and any necessary permits must be obtained. 4. Pollution prevention plan. A pollution prevention plan that addresses potential pollutant -generating activities that may reasonably be expected to affect the quality of stormwater discharges from the construction activity, including any support activity. The pollution prevention plan shall: a. Identify the potential pollutant -generating activities and the pollutant that is expected to be exposed to stormwater; b. Describe the location where the potential pollutant -generating activities will occur, or if identified on the site plan, reference the site plan; c. Identify all nonstormwater discharges, as authorized in Part I E of this general permit, that are or will be commingled with stormwater discharges from the construction activity, including any applicable support activity; d. Identify the person responsible for implementing the pollution prevention practice or practices for each pollutant -generating activity (if other than the person listed as the qualified personnel); e. Describe the pollution prevention practices and procedures that will be implemented to: (1) Prevent and respond to leaks, spills, and other releases including (i) procedures for expeditiously stopping, containing, and cleaning up spills, leaks, and other releases; and (ii) procedures for reporting leaks, spills, and other releases in accordance with Part III G; (2) Prevent the discharge of spilled and leaked fuels and chemicals from vehicle fueling and maintenance activities (e.g., providing secondary containment such as spill berms, decks, spill containment pallets, providing cover where appropriate, and having spill kits readily available); General Permit No.: VAR10 Page 8 of 21 (3) Prevent the discharge of soaps, solvents, detergents, and wash water from construction materials, including the clean-up of stucco, paint, form release oils, and curing compounds (e.g., providing (i) cover (e.g., plastic sheeting or temporary roofs) to prevent contact with stormwater; (ii) collection and proper disposal in a manner to prevent contact with stormwater; and (iii) a similarly effective means designed to prevent discharge of these pollutants); (4) Minimize the discharge of pollutants from vehicle and equipment washing, wheel wash water, and other types of washing (e.g., locating activities away from surface waters and stormwater inlets or conveyance and directing wash waters to sediment basins or traps, using filtration devices such as filter bags or sand filters, or using similarly effective controls); (5) Direct concrete wash water into a leak -proof container or leak -proof settling basin. The container or basin shall be designed so that no overflows can occur due to inadequate sizing or precipitation. Hardened concrete wastes shall be removed and disposed of in a manner consistent with the handling of other construction wastes. Liquid concrete wastes shall be removed and disposed of in a manner consistent with the handling of other construction wash waters and shall not be discharged to surface waters; (6) Minimize the discharge of pollutants from storage, handling, and disposal of construction products, materials, and wastes including (i) building products such as asphalt sealants, copper flashing, roofing materials, adhesives, and concrete admixtures; (ii) pesticides, herbicides, insecticides, fertilizers, and landscape materials; and (iii) construction and domestic wastes such as packaging materials, scrap construction materials, masonry products, timber, pipe and electrical cuttings, plastics, Styrofoam, concrete, and other trash or building materials; (7) Prevent the discharge of fuels, oils, and other petroleum products, hazardous or toxic wastes, and sanitary wastes; and (8) Address any other discharge from the potential pollutant -generating activities not addressed above; and f. Describe procedures for providing pollution prevention awareness of all applicable wastes, including any wash water, disposal practices, and applicable disposal locations of such wastes, to personnel in order to comply with the conditions of this general permit. The operator shall implement the procedures described in the SWPPP. 5. SWPPP requirements for discharges to impaired waters, surface waters with an applicable TMDL wasteload allocation established and approved prior to the term of this general permit, and exceptional waters. The SWPPP shall: a. Identify the impaired water(s), approved TMDL(s), pollutant(s) of concern, and exceptional waters identified in 9VAC25-260-30 A 3 c, when applicable; b. Provide clear direction that: (1) Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site; (2) Nutrients shall be applied in accordance with manufacturer's recommendations or an approved nutrient management plan and shall not be applied during rainfall events; and (3) A modified inspection schedule shall be implemented in accordance with Part I B 4 or Part I B 5. General Permit No.: VAR10 Page 9 of 21 6. Qualified personnel. The name, phone number, and qualifications of the qualified personnel conducting inspections required by this general permit. 7. Delegation of authority. The individuals or positions with delegated authority, in accordance with Part III K, to sign inspection reports or modify the SWPPP. 8. SWPPP signature. The SWPPP shall be signed and dated in accordance with Part III K. B. SWPPP amendments, modification, and updates. 1. The operator shall amend the SWPPP whenever there is a change in the design, construction, operation, or maintenance that has a significant effect on the discharge of pollutants to surface waters and that has not been previously addressed in the SWPPP. 2. The SWPPP must be amended if, during inspections or investigations by the operator's qualified personnel, or by local, state, or federal officials, it is determined that the existing control measures are ineffective in minimizing pollutants in discharges from the construction activity. Revisions to the SWPPP shall include additional or modified control measures designed and implemented to correct problems identified. If approval by the VESCP authority, VSMP authority, or department is necessary for the control measure, revisions to the SWPPP shall be completed no later than seven calendar days following approval. Implementation of these additional or modified control measures must be accomplished as described in Part II G. 3. The SWPPP must clearly identify the contractor(s) that will implement and maintain each control measure identified in the SWPPP. The SWPPP shall be amended to identify any new contractor that will implement and maintain a control measure. 4. The operator shall update the SWPPP no later than seven days following any modification to its implementation. All modifications or updates to the SWPPP shall be noted and shall include the following items: a. A record of dates when: (1) Major grading activities occur; (2) Construction activities temporarily or permanently cease on a portion of the site; and (3) Stabilization measures are initiated; b. Documentation of replaced or modified controls where periodic inspections or other information have indicated that the controls have been used inappropriately or incorrectly and where modified as soon as possible; c. Areas that have reached final stabilization and where no further SWPPP or inspection requirements apply; d. All properties that are no longer under the legal control of the operator and the dates on which the operator no longer had legal control over each property; e. The date of any prohibited discharges, the discharge volume released, and what actions were taken to minimize the impact of the release; f. Measures taken to prevent the reoccurrence of any prohibited discharge; and g. Measures taken to address any evidence identified as a result of an inspection required under Part 11 F. General Permit No.: VAR10 Page 10 of 21 5. Amendments, modifications, or updates to the SWPPP shall be signed in accordance with Part III K. C. Public Notification. Upon commencement of land disturbance, the operator shall post conspicuously a copy of the notice of coverage letter near the main entrance of the construction activity. For linear projects, the operator shall post the notice of coverage letter at a publicly accessible location near an active part of the construction project (e.g., where a pipeline crosses a public road). The operator shall maintain the posted information until termination of general permit coverage as specified in Part I F. D. SWPPP availability. 1. Operators with day-to-day operational control over SWPPP implementation shall have a copy of the SWPPP available at a central location on -site for use by those identified as having responsibilities under the SWPPP whenever they are on the construction site. 2. The operator shall make the SWPPP and all amendments, modifications, and updates available upon request to the department, the VSMP authority, the EPA, the VESCP authority, local government officials, or the operator of a municipal separate storm sewer system receiving discharges from the construction activity. If an on -site location is unavailable to store the SWPPP when no personnel are present, notice of the SWPPP's location must be posted near the main entrance of the construction site. 3. The operator shall make the SWPPP available for public review in an electronic format or in hard copy. Information for public access to the SWPPP shall be posted and maintained in accordance with Part II C. If not provided electronically, public access to the SWPPP may be arranged upon request at a time and at a publicly accessible location convenient to the operator or his designee but shall be no less than once per month and shall be during normal business hours. Information not required to be contained within the SWPPP by this general permit is not required to be released. E. SWPPP implementation. The operator shall implement the SWPPP and subsequent amendments, modifications, and updates from commencement of land disturbance until termination of general permit coverage as specified in Part I F. 1. All control measures must be properly maintained in effective operating condition in accordance with good engineering practices and, where applicable, manufacturer specifications. If a site inspection required by Part II F identifies a control measure that is not operating effectively, corrective action(s) shall be completed as soon as practicable, but no later than seven days after discovery or a longer period as established by the VSMP authority, to maintain the continued effectiveness of the control measures. 2. If site inspections required by Part II F identify an existing control measure that needs to be modified or if an additional control measure is necessary for any reason, implementation shall be completed prior to the next anticipated measurable storm event. If implementation prior to the next anticipated measurable storm event is impracticable, then alternative control measures shall be implemented as soon as practicable, but no later than seven days after discovery or a longer period as established by the VSMP authority. F. SWPPP Inspections. 1. Personnel responsible for on -site and off -site inspections. Inspections required by this general permit shall be conducted by the qualified personnel identified by the operator in the SWPPP. The operator is responsible for insuring that the qualified personnel conduct the inspection. 2. Inspection schedule. a. Inspections shall be conducted at a frequency of: General Permit No.: VAR10 Page 11 of 21 (1) At least once every five business days; or (2) At least once every 10 business days and no later than 48 hours following a measurable storm event. In the event that a measurable storm event occurs when there are more than 48 hours between business days, the inspection shall be conducted no later than the next business day. b. Where areas have been temporarily stabilized or land -disturbing activities will be suspended due to continuous frozen ground conditions and stormwater discharges are unlikely, the inspection frequency may be reduced to once per month. If weather conditions (such as above freezing temperatures or rain or snow events) make discharges likely, the operator shall immediately resume the regular inspection frequency. c. Representative inspections may be utilized for utility line installation, pipeline construction, or other similar linear construction activities provided that: (1) Temporary or permanent soil stabilization has been installed and vehicle access may compromise the temporary or permanent soil stabilization and potentially cause additional land disturbance increasing the potential for erosion; (2) Inspections occur on the same frequency as other construction activities; (3) Control measures are inspected along the construction site 0.25 miles above and below each access point (i.e., where a roadway, undisturbed right-of-way, or other similar feature intersects the construction activity and access does not compromise temporary or permanent soil stabilization); and (4) Inspection locations are provided in the report required by Part II F. 3. Inspection requirements. a. As part of the inspection, the qualified personnel shall: (1) Record the date and time of the inspection and when applicable the date and rainfall amount of the last measurable storm event; (2) Record the information and a description of any discharges occurring at the time of the inspection; (3) Record any land -disturbing activities that have occurred outside of the approved erosion and sediment control plan; (4) Inspect the following for installation in accordance with the approved erosion and sediment control plan, identification of any maintenance needs, and evaluation of effectiveness in minimizing sediment discharge, including whether the control has been inappropriately or incorrectly used: (a) All perimeter erosion and sediment controls, such as silt fence; (b) Soil stockpiles, when applicable, and borrow areas for stabilization or sediment trapping measures; (c) Completed earthen structures, such as dams, dikes, ditches, and diversions for stabilization; General Permit No.: VAR10 Page 12 of 21 (d) Cut and fill slopes; (e) Sediment basins and traps, sediment barriers, and other measures installed to control sediment discharge from stormwater; (f) Temporary or permanent channel, flume, or other slope drain structures installed to convey concentrated runoff down cut and fill slopes; (g) Storm inlets that have been made operational to ensure that sediment laden stormwater does not enter without first being filtered or similarly treated; and (h) Construction vehicle access routes that intersect or access paved roads for minimizing sediment tracking; (5) Inspect areas that have reached final grade or that will remain dormant for more than 14 days for initiation of stabilization activities; (6) Inspect areas that have reached final grade or that will remain dormant for more than 14 days for completion of stabilization activities within seven days of reaching grade or stopping work; (7) Inspect for evidence that the approved erosion and sediment control plan, "agreement in lieu of a plan," or erosion and sediment control plan prepared in accordance with department - approved annual standards and specifications has not been properly implemented. This includes but is not limited to: (a) Concentrated flows of stormwater in conveyances such as rills, rivulets or channels that have not been filtered, settled, or similarly treated prior to discharge, or evidence thereof; (b) Sediment laden or turbid flows of stormwater that have not been filtered or settled to remove sediments prior to discharge; (c) Sediment deposition in areas that drain to unprotected stormwater inlets or catch basins that discharge to surface waters. Inlets and catch basins with failing sediments controls due to improper installation, lack of maintenance, or inadequate design are considered unprotected; (d) Sediment deposition on any property (including public and private streets) outside of the construction activity covered by this general permit; (e) Required stabilization has not been initiated or completed on portions of the site; (f) Sediment basins without adequate wet or dry storage volume or sediment basins that allow the discharge of stormwater from below the surface of the wet storage portion of the basin; (g) Sediment traps without adequate wet or dry storage or sediment traps that allow the discharge of stormwater from below the surface of the wet storage portion of the trap; and (h) Land disturbance outside of the approved area to be disturbed; (8) Inspect pollutant generating activities identified in the pollution prevention plan for the proper implementation, maintenance and effectiveness of the procedures and practices; (9) Identify any pollutant generating activities not identified in the pollution prevention plan; and General Permit No.: VAR10 Page 13 of 21 (10) Identify and document the presence of any evidence of the discharge of pollutants prohibited by this general permit. 4. Inspection report. Each inspection report shall include the following items: a. The date and time of the inspection and when applicable, the date and rainfall amount of the last measurable storm event; b. Summarized findings of the inspection; c. The location(s) of prohibited discharges; d. The location(s) of control measures that require maintenance; e. The location(s) of control measures that failed to operate as designed or proved inadequate or inappropriate for a particular location; f. The location(s) where any evidence identified under Part II F 3 a (7) exists; g. The location(s) where any additional control measure is needed that did not exist at the time of inspection; h. A list of corrective actions required (including any changes to the SWPPP that are necessary) as a result of the inspection or to maintain permit compliance; i. Documentation of any corrective actions required from a previous inspection that have not been implemented; and j. The date and signature of the qualified personnel and the operator or its duly authorized representative. The inspection report and any actions taken in accordance with Part II must be retained by the operator as part of the SWPPP for at least three years from the date that general permit coverage expires or is terminated. The inspection report shall identify any incidents of noncompliance. Where an inspection report does not identify any incidents of noncompliance, the report shall contain a certification that the construction activity is in compliance with the SWPPP and this general permit. The report shall be signed in accordance with Part III K of this general permit. G. Corrective actions. 1. The operator shall implement the corrective action(s) identified as a result of an inspection as soon as practicable but no later than seven days after discovery or a longer period as approved by the VSMP authority. If approval of a corrective action by a regulatory authority (e.g., VSMP authority, VESCP authority, or the department) is necessary, additional control measures shall be implemented to minimize pollutants in stormwater discharges until such approvals can be obtained. 2. The operator may be required to remove accumulated sediment deposits located outside of the construction activity covered by this general permit as soon as practicable in order to minimize environmental impacts. The operator shall notify the VSMP authority and the department as well as obtain all applicable federal, state, and local authorizations, approvals, and permits prior to the removal of sediments accumulated in surface waters including wetlands. General Permit No.: VAR10 Page 14 of 21 PART III CONDITIONS APPLICABLE TO ALL VPDES PERMITS NOTE: Discharge monitoring is not required for this general permit. If the operator chooses to monitor stormwater discharges or control measures, the operator must comply with the requirements of subsections A, B, and C, as appropriate. A. Monitoring. 1. Samples and measurements taken for the purpose of monitoring shall be representative of the monitoring activity. 2. Monitoring shall be conducted according to procedures approved under 40 CFR Part 136 or alternative methods approved by the U.S. Environmental Protection Agency, unless other procedures have been specified in this general permit. Analyses performed according to test procedures approved under 40 CFR Part 136 shall be performed by an environmental laboratory certified under regulations adopted by the Department of General Services (1 VAC30-45 or 1 VAC30-46). 3. The operator shall periodically calibrate and perform maintenance procedures on all monitoring and analytical instrumentation at intervals that will ensure accuracy of measurements. B. Records. 1. Monitoring records and reports shall include: a. The date, exact place, and time of sampling or measurements; b. The individual(s) who performed the sampling or measurements; c. The date(s) and time(s) analyses were performed; d. The individual(s) who performed the analyses; e. The analytical techniques or methods used; and f. The results of such analyses. 2. The operator shall retain records of all monitoring information, including all calibration and maintenance records and all original strip chart recordings for continuous monitoring instrumentation, copies of all reports required by this general permit, and records of all data used to complete the registration statement for this general permit, for a period of at least three years from the date of the sample, measurement, report or request for coverage. This period of retention shall be extended automatically during the course of any unresolved litigation regarding the regulated activity or regarding control standards applicable to the operator, or as requested by the board. C. Reporting monitoring results. 1. The operator shall update the SWPPP to include the results of the monitoring as may be performed in accordance with this general permit, unless another reporting schedule is specified elsewhere in this general permit. 2. Monitoring results shall be reported on a discharge monitoring report (DMR); on forms provided, approved or specified by the department; or in any format provided that the date, location, parameter, method, and result of the monitoring activity are included. General Permit No.: VAR10 Page 15 of 21 3. If the operator monitors any pollutant specifically addressed by this general permit more frequently than required by this general permit using test procedures approved under 40 CFR Part 136 or using other test procedures approved by the U.S. Environmental Protection Agency or using procedures specified in this general permit, the results of this monitoring shall be included in the calculation and reporting of the data submitted in the DMR or reporting form specified by the department. 4. Calculations for all limitations which require averaging of measurements shall utilize an arithmetic mean unless otherwise specified in this general permit. D. Duty to provide information. The operator shall furnish, within a reasonable time, any information which the board may request to determine whether cause exists for modifying, revoking and reissuing, or terminating this general permit or to determine compliance with this general permit. The board, department, EPA, or VSMP authority may require the operator to furnish, upon request, such plans, specifications, and other pertinent information as may be necessary to determine the effect of the wastes from his discharge on the quality of surface waters, or such other information as may be necessary to accomplish the purposes of the CWA and the Virginia Stormwater Management Act. The operator shall also furnish to the board, department, EPA, or VSMP authority, upon request, copies of records required to be kept by this general permit. E. Compliance schedule reports. Reports of compliance or noncompliance with, or any progress reports on, interim and final requirements contained in any compliance schedule of this general permit shall be submitted no later than 14 days following each schedule date. F. Unauthorized stormwater discharges. Pursuant to § 62.1-44.5 of the Code of Virginia, except in compliance with a state permit issued by the department, it shall be unlawful to cause a stormwater discharge from a construction activity. G. Reports of unauthorized discharges. Any operator who discharges or causes or allows a discharge of sewage, industrial waste, other wastes or any noxious or deleterious substance or a hazardous substance or oil in an amount equal to or in excess of a reportable quantity established under either 40 CFR Part 110, 40 CFR Part 117, 40 CFR Part 302, or § 62.1-44.34:19 of the Code of Virginia that occurs during a 24-hour period into or upon surface waters or who discharges or causes or allows a discharge that may reasonably be expected to enter surface waters, shall notify the Department of Environmental Quality of the discharge immediately upon discovery of the discharge, but in no case later than within 24 hours after said discovery. A written report of the unauthorized discharge shall be submitted to the department and the VSMP authority within five days of discovery of the discharge. The written report shall contain: 1. A description of the nature and location of the discharge; 2. The cause of the discharge; 3. The date on which the discharge occurred; 4. The length of time that the discharge continued; 5. The volume of the discharge; 6. If the discharge is continuing, how long it is expected to continue; 7. If the discharge is continuing, what the expected total volume of the discharge will be; and 8. Any steps planned or taken to reduce, eliminate and prevent a recurrence of the present discharge or any future discharges not authorized by this general permit. General Permit No.: VAR10 Page 16 of 21 Discharges reportable to the department and the VSMP authority under the immediate reporting requirements of other regulations are exempted from this requirement. H. Reports of unusual or extraordinary discharges. If any unusual or extraordinary discharge including a "bypass" or "upset," as defined herein, should occur from a facility and the discharge enters or could be expected to enter surface waters, the operator shall promptly notify, in no case later than within 24 hours, the department and the VSMP authority by telephone after the discovery of the discharge. This notification shall provide all available details of the incident, including any adverse effects on aquatic life and the known number of fish killed. The operator shall reduce the report to writing and shall submit it to the department and the VSMP authority within five days of discovery of the discharge in accordance with Part III 1 2. Unusual and extraordinary discharges include but are not limited to any discharge resulting from: 1. Unusual spillage of materials resulting directly or indirectly from processing operations; 2. Breakdown of processing or accessory equipment; 3. Failure or taking out of service of some or all of the facilities; and 4. Flooding or other acts of nature. I. Reports of noncompliance. The operator shall report any noncompliance which may adversely affect surface waters or may endanger public health. 1. An oral report to the department and the VSMP authority shall be provided within 24 hours from the time the operator becomes aware of the circumstances. The following shall be included as information that shall be reported within 24 hours under this subdivision: a. Any unanticipated bypass; and b. Any upset that causes a discharge to surface waters. 2. A written report shall be submitted within five days and shall contain: a. A description of the noncompliance and its cause; b. The period of noncompliance, including exact dates and times, and if the noncompliance has not been corrected, the anticipated time it is expected to continue; and c. Steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance. The department may waive the written report on a case -by -case basis for reports of noncompliance under Part III I if the oral report has been received within 24 hours and no adverse impact on surface waters has been reported. 3. The operator shall report all instances of noncompliance not reported under Part III 1 1 or 2 in writing as part of the SWPPP. The reports shall contain the information listed in Part III 12. NOTE: The reports required in Part III G, H and I shall be made to the department and the VSMP authority. Reports may be made by telephone, email, or by fax. For reports outside normal working hours, leaving a recorded message shall fulfill the immediate reporting requirement. For emergencies, the Virginia Department of Emergency Management maintains a 24-hour telephone service at 1-800-468- 8892. General Permit No.: VAR10 Page 17 of 21 4. Where the operator becomes aware of a failure to submit any relevant facts, or submittal of incorrect information in any report, including a registration statement, to the department or the VSMP authority, the operator shall promptly submit such facts or correct information. J. Notice of planned changes. 1. The operator shall give notice to the department and the VSMP authority as soon as possible of any planned physical alterations or additions to the permitted facility or activity. Notice is required only when: a. The operator plans an alteration or addition to any building, structure, facility, or installation that may meet one of the criteria for determining whether a facility is a new source in 9VAC25-870- 420; b. The operator plans an alteration or addition that would significantly change the nature or increase the quantity of pollutants discharged. This notification applies to pollutants that are not subject to effluent limitations in this general permit; or 2. The operator shall give advance notice to the department and VSMP authority of any planned changes in the permitted facility or activity, which may result in noncompliance with state permit requirements. K. Signatory requirements. 1. Registration statement. All registration statements shall be signed as follows: a. For a corporation: by a responsible corporate officer. For the purpose of this chapter, a responsible corporate officer means: (i) a president, secretary, treasurer, or vice-president of the corporation in charge of a principal business function, or any other person who performs similar policy -making or decision -making functions for the corporation; or (ii) the manager of one or more manufacturing, production, or operating facilities, provided the manager is authorized to make management decisions that govern the operation of the regulated facility including having the explicit or implicit duty of making major capital investment recommendations, and initiating and directing other comprehensive measures to assure long-term compliance with environmental laws and regulations; the manager can ensure that the necessary systems are established or actions taken to gather complete and accurate information for state permit application requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures; b. For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or c. For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. For purposes of this chapter, a principal executive officer of a public agency includes: (i) the chief executive officer of the agency or (ii) a senior executive officer having responsibility for the overall operations of a principal geographic unit of the agency. 2. Reports, etc. All reports required by this general permit, including SWPPPs, and other information requested by the board or the department shall be signed by a person described in Part III K 1 or by a duly authorized representative of that person. A person is a duly authorized representative only if: a. The authorization is made in writing by a person described in Part III K 1; b. The authorization specifies either an individual or a position having responsibility for the overall operation of the regulated facility or activity such as the position of plant manager, operator of a well or a well field, superintendent, position of equivalent responsibility, or an individual or position having overall responsibility for environmental matters for the operator. (A duly authorized General Permit No.: VAR10 Page 18 of 21 representative may thus be either a named individual or any individual occupying a named position); and c. The signed and dated written authorization is included in the SWPPP. A copy must be provided to the department and VSMP authority, if requested. 3. Changes to authorization. If an authorization under Part III K 2 is no longer accurate because a different individual or position has responsibility for the overall operation of the construction activity, a new authorization satisfying the requirements of Part III K 2 shall be submitted to the VSMP authority as the administering entity for the board prior to or together with any reports or information to be signed by an authorized representative. 4. Certification. Any person signing a document under Part III K 1 or 2 shall make the following certification: "I certify under penalty of law that I have read and understand this document and that this document and all attachments were prepared in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations." L. Duty to comply. The operator shall comply with all conditions of this general permit. Any state permit noncompliance constitutes a violation of the Virginia Stormwater Management Act and the Clean Water Act, except that noncompliance with certain provisions of this general permit may constitute a violation of the Virginia Stormwater Management Act but not the Clean Water Act. Permit noncompliance is grounds for enforcement action; for state permit termination, revocation and reissuance, or modification; or denial of a state permit renewal application. The operator shall comply with effluent standards or prohibitions established under § 307(a) of the Clean Water Act for toxic pollutants within the time provided in the regulations that establish these standards or prohibitions or standards for sewage sludge use or disposal, even if this general permit has not yet been modified to incorporate the requirement. M. Duty to reapply. If the operator wishes to continue an activity regulated by this general permit after the expiration date of this general permit, the operator shall submit a new registration statement at least 90 days before the expiration date of the existing general permit, unless permission for a later date has been granted by the board. The board shall not grant permission for registration statements to be submitted later than the expiration date of the existing general permit. N. Effect of a state permit. This general permit does not convey any property rights in either real or personal property or any exclusive privileges, nor does it authorize any injury to private property or invasion of personal rights, or any infringement of federal, state or local law or regulations. O. State law. Nothing in this general permit shall be construed to preclude the institution of any legal action under, or relieve the operator from any responsibilities, liabilities, or penalties established pursuant to any other state law or regulation or under authority preserved by § 510 of the Clean Water Act. Except as provided in general permit conditions on "bypassing" (Part III U) and "upset' (Part III V), nothing in this general permit shall be construed to relieve the operator from civil and criminal penalties for noncompliance. P. Oil and hazardous substance liability. Nothing in this general permit shall be construed to preclude the institution of any legal action or relieve the operator from any responsibilities, liabilities, or penalties to which the operator is or may be subject under §§ 62.1-44.34:14 through 62.1-44.34:23 of the State Water Control Law or § 311 of the Clean Water Act. General Permit No.: VAR10 Page 19 of 21 Q. Proper operation and maintenance. The operator shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances), which are installed or used by the operator to achieve compliance with the conditions of this general permit. Proper operation and maintenance also includes effective plant performance, adequate funding, adequate staffing, and adequate laboratory and process controls, including appropriate quality assurance procedures. This provision requires the operation of back-up or auxiliary facilities or similar systems, which are installed by the operator only when the operation is necessary to achieve compliance with the conditions of this general permit. R. Disposal of solids or sludges. Solids, sludges or other pollutants removed in the course of treatment or management of pollutants shall be disposed of in a manner so as to prevent any pollutant from such materials from entering surface waters and in compliance with all applicable state and federal laws and regulations. S. Duty to mitigate. The operator shall take all steps to minimize or prevent any discharge in violation of this general permit that has a reasonable likelihood of adversely affecting human health or the environment. T. Need to halt or reduce activity not a defense. It shall not be a defense for an operator in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with the conditions of this general permit. U. Bypass. 1. 'Bypass," as defined in 9VAC25-870-10, means the intentional diversion of waste streams from any portion of a treatment facility. The operator may allow any bypass to occur that does not cause effluent limitations to be exceeded, but only if it also is for essential maintenance to ensure efficient operation. These bypasses are not subject to the provisions of Part III U 2 and 3. 2. Notice a. Anticipated bypass. If the operator knows in advance of the need for a bypass, the operator shall submit prior notice to the department, if possible at least 10 days before the date of the bypass. b. Unanticipated bypass. The operator shall submit notice of an unanticipated bypass as required in Part III I. 3. Prohibition of bypass. a. Except as provided in Part III U 1, bypass is prohibited, and the board or department may take enforcement action against an operator for bypass unless: (1) Bypass was unavoidable to prevent loss of life, personal injury, or severe property damage. Severe property damage means substantial physical damage to property, damage to the treatment facilities that causes them to become inoperable, or substantial and permanent loss of natural resources that can reasonably be expected to occur in the absence of a bypass. Severe property damage does not mean economic loss caused by delays in production; (2) There were no feasible alternatives to the bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes, or maintenance during normal periods of equipment downtime. This condition is not satisfied if adequate back-up equipment should have been installed in the exercise of reasonable engineering judgment to prevent a bypass that occurred during normal periods of equipment downtime or preventive maintenance; and (3) The operator submitted notices as required under Part III U 2. General Permit No.: VAR10 Page 20 of 21 b. The department may approve an anticipated bypass, after considering its adverse effects, if the department determines that it will meet the three conditions listed in Part III U 3 a. V. Upset. 1. An "upset," as defined in 9VAC25-870-10, means an exceptional incident in which there is unintentional and temporary noncompliance with technology -based state permit effluent limitations because of factors beyond the reasonable control of the operator. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventive maintenance, or careless or improper operation. 2. An upset constitutes an affirmative defense to an action brought for noncompliance with technology - based state permit effluent limitations if the requirements of Part III V 4 are met. A determination made during administrative review of claims that noncompliance was caused by upset, and before an action for noncompliance, is not a final administrative action subject to judicial review. 3. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventative maintenance, or careless or improper operation. 4. An operator who wishes to establish the affirmative defense of upset shall demonstrate, through properly signed, contemporaneous operating logs or other relevant evidence that: a. An upset occurred and that the operator can identify the cause(s) of the upset; b. The permitted facility was at the time being properly operated; c. The operator submitted notice of the upset as required in Part III I; and d. The operator complied with any remedial measures required under Part III S. 5. In any enforcement proceeding, the operator seeking to establish the occurrence of an upset has the burden of proof. W. Inspection and entry. The operator shall allow the department as the board's designee, the VSMP authority, EPA, or an authorized representative of either entity (including an authorized contractor), upon presentation of credentials and other documents as may be required by law to: 1. Enter upon the operator's premises where a regulated facility or activity is located or conducted, or where records must be kept under the conditions of this general permit; 2. Have access to and copy, at reasonable times, any records that must be kept under the conditions of this general permit; 3. Inspect and photograph at reasonable times any facilities, equipment (including monitoring and control equipment), practices, or operations regulated or required under this general permit; and 4. Sample or monitor at reasonable times, for the purposes of ensuring state permit compliance or as otherwise authorized by the Clean Water Act or the Virginia Stormwater Management Act, any substances or parameters at any location. For purposes of this section, the time for inspection shall be deemed reasonable during regular business hours, and whenever the facility is discharging. Nothing contained herein shall make an inspection unreasonable during an emergency. General Permit No.: VAR10 Page 21 of 21 X. State permit actions. State permits may be modified, revoked and reissued, or terminated for cause. The filing of a request by the operator for a state permit modification, revocation and reissuance, or termination, or a notification of planned changes or anticipated noncompliance does not stay any state permit condition. Y. Transfer of state permits. 1. State permits are not transferable to any person except after notice to the department. Except as provided in Part III Y 2, a state permit may be transferred by the operator to a new operator only if the state permit has been modified or revoked and reissued, or a minor modification made, to identify the new operator and incorporate such other requirements as may be necessary under the Virginia Stormwater Management Act and the Clean Water Act. 2. As an alternative to transfers under Part III Y 1, this state permit may be automatically transferred to a new operator if: a. The current operator notifies the department at least 30 days in advance of the proposed transfer of the title to the facility or property; b. The notice includes a written agreement between the existing and new operators containing a specific date for transfer of state permit responsibility, coverage, and liability between them; and c. The department does not notify the existing operator and the proposed new operator of its intent to modify or revoke and reissue the state permit. If this notice is not received, the transfer is effective on the date specified in the agreement mentioned in Part III Y 2 b. 3. For ongoing construction activity involving a change of operator, the new operator shall accept and maintain the existing SWPPP, or prepare and implement a new SWPPP prior to taking over operations at the site. Z. Severability. The provisions of this general permit are severable, and if any provision of this general permit or the application of any provision of this state permit to any circumstance, is held invalid, the application of such provision to other circumstances and the remainder of this general permit shall not be affected thereby. Section 12. Inspection logs (Provide templates for your inspections. Requirements are listed in 9VAC25-880-70, Part II, section B and F.) Issued 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County 6 Z_ Z Z 3 uj m Y W W 3 W 2 O U. Z 2 O H Z O 2 a) r410 u aJ u to co a � 3 0 Q Y cu t A 7 N_ E Q L a ' O a1 4 fv fn ra _v N Y � Lar in O o u 4, N aJ L L � � 7 O_41 O r0 E d0 c O in t10 V N a L l0 T m c d L c C O E a c C O 0 as O m o m � fi � O E -P o O N U m o� N a) O U co c U O An U U 1 cts =r _ N rN > O O O O N 2 w c •E -a CD E IL 'm 0 Q .E E o .ro CM LL a) N C a a) 0 c LEj 3 m m m U) N U O c U N 0) a) N in cca En c c O U U 7 m aw cc 0 U N c m i a1 N M O c O u W M N O c M u H aJ G Z T d M O a tic c m a! M O c 0 r 0. c O d E v c m v m C c 0 a w C a T u m LL m_ Er 0 m �a 0 ro � E v oO U (n ro O N U U m� ca a c U O N U 1-0 ro ~= w fq > O O O 2 Q ED a) � cn a 'ro a) a E o m N � LL N � •C a� o �- N cn U a) m m N U O :3 c U N a) a) cd :? N) cis C 0 � U U i CD U) Vl N O c O U 0 r y c v Y r m c m E O +• o :0 o N r N a 7 �+ E N E M cu m E vOi O w a m O 7 O m c Mn } E v am) - v o G u c .c L N 7 O O +. r w u u m r E a) CU ro i O •� `J �, C vui 0. -0 m cu O N c -0 +' a) v c w c M >, .2 al a) y m a W r dim r aJ al c � r W A• E c cu z N N in ai O 'n 41 c `u > L m o a p°f0 E —a u L s 0 a m O N LA c O 01 t tA cu � N C � L 7 h tw r :2o ,A LL u a) m 0 L W y O fro m = m m u mu 7 E O C frn v a 0 W c 0 c a a (.uL E aJ >, O N V E U X m � L � v= O aJ � Y � o m C 0 m N N O � c O N o c �) a •-" a) L o v 3 v bD � � L ai > U to O L v L aJ N a� ra a c L � � a) 4, a u c 0 N N N a) a) o a a1 In a) a N a) fro v= OA O 4- O 0 u c u c a 7 Ecu Z L O m L YE O m t T O a) +' M1• T s N a) Y v on L N -0 L (� ai •L U -0 u {) a) .7 a) N Y N a a 4J r L a a m Ln u E u a) v 3 v a, N E s E O a) N C a) v a) L N Y N —_ 'A 0 c o tci c O U m Y U In N aj O vOj N O p .c Ln c v o ao� 'u�Ln U LLI O 0: a 6 Z_ Z Z 0 LL! m Y LU LU LU H O: O LL (D Z rz O H Z O 2 N 41 l0 u a) u GD m v Y L O CL L Y a) t �- 7 VJ E Q L 4-- 0 a1 Y Y Y a1 y +�+ a) a) +, L +1 O O 0 u Y — a1 aJ Y i 7 m 7 a C (4�6 E to c o in oA u � c t M m V m E r oCL N O ro m 3 .c E 72 O O U N m N a) O U rn:3 ro10 Uc O N U �-0 a� N w (N N N > r- a) O 0 2 N . O E� a) � ro a E_� 0 m ro a o rnCD 0 CD � 3 ro ro a� N o U N E: U ro co � aJ L U N ro c O U U 7 ro a 5 N c o U IA C m GJ Ln O C O u N CL C O C O a u v O Z T aJ CL O a` 00 c f0 a °. O C O u d CL c 0 v E C m d fY0 c C O f410 u w C aJ M m LL a m Er o ro �a o m of 3 E'2 0 0 U N N O -, N m O U OJ > Ca 10 L O _N U N � N > O O O 2 oa �F; C C � a) a� LO E O N LL N m c o CD .c- 2 c ro U U roca a� O N U O 7 c o ro U N aJ L .O ca U) ro ca O O '— U i N ay N c C O U 0 a+ y c � Yate+ N C rp 3 O v +' O + 16 7 � r0 N E L 00 C a � rua c Y m E h aJ O O aJ CL m > > O ro }' Y c -o C a) M '0 aJ O u O c .c � T O v U E L i In C 7 0 c0 aj X u GJ u 4-u roIn m Y c " — % Oaj al to G. _0— O ro N °N ro a+ C O -O 'O — VI d m T Y f0 O T Y N ro -O � w Y r C v c c v aJ n. ,� v � L � 0 o ai a3J rn W ` L LD aJ 3 ro > cu u aJ tn 4 L o •� L A 0 N 0 0 3 D at-+ a E ai O ro L O Ln V N aJ O aJ Ln aJ 3 c a Os aJ rroo V, y� w O w ro O L Y u o c 6 c o aJ 7O Z 0 a, m " C -8 aL O CL 0 m C >- Ln 7 (�: N M1- ai Y Y aJ 00 •L VI L i u u u C 41 a) u aJ V h c ° QJ ++ v v °' LL _0 N ro aj U -0 L u -a'o Y V L n ar 3 a`J aJ U L aJ E + u -0 O c t E c c 3 :3 a a, c L a, v �' -Cas - t a+ O ' 7 vO O O c O L c N O u ro *' U Ul aJ ' d y O O Ln Lq 41 M = +' O O 3r �,� v ~= c c al CA G `^ ,°' .a0i o o L O a) l0 7 u bLO co � L O O Q- L O (U T 7 E Q +' O v L N to + + -0 (, F a) Q1 4L u O O a•+ 7 a) L _ 4• � Q C C cu C tio c O V1 L ra 4-1 a m V Z Z z a MW W Y W W W r O LL Q Z R O t Z O 2 v m E r oa � O iV 0) 3 .E E -2 o ° U m O-0 rn m O U m � L E U O (q U � al o� ro L N N N > 0 •O O N E� m � d a7 d E ° L ro roC: a� o .- N C t, cV N 7 N U ° 7 10 1 9-- o m U N a) al a7 :- w m m E E O O U U 7 o aw w c O U N c m al N O c u al a N c 0 O 4.1 Q. .`u N Z } T O. O a` on c m L a) a O C O Y al Q. O as E m m 0 41 O C 4a m C aJ m LL 10 m E M �d o m 0) 3 •c E U N 0 O y d 2 U ° m 10 E Uil U 0 a) 1-0 (n > N > E U O O 0 2 � F. 0 i a) a7 d .ca a) O. rL E O w S O O is Y ++ co f0 7E O f0 Ea C LA o y a E in m '0 ai Q aJ O u O .� aJ C O O O r O 41 W U u f a+ E A c Y aJ y fC O U N O. CU r O C O inIAr d QJ Y � � f0 4. a! ,u C t E c � •a, T d s N N y N 3 -93 _O N aO+ C 9 co O c ° 3 -o f0 E — O u L tv a rco Q LA c y Or N O a aLn EA dd C N 4 O •O O LL m u aJ m 0 N N O 41 `0 m - W 3 m E N 5 O C cu of -a 72 0 N OA C O c � a � E > _T O v u E ,� QJ i U X � a1 i N O L � Y � O r-I v1 O O f6 N N o LA O N O c v T N al L o v 3 a, E9 t � aj 3 M > L U N to N p N t (J U IA Y aJ N M aL+ .3 u c 0 y N N � 0 � t10 v N a) 3 Q N aJ ca o Ca O w m o ro I o c N } 7 v D E z t O L O m t > O N M1. T t N aJ N 0 N 'L C U U aJ U N Y 1 � � L a/ N u 3 N u a u 3 `o Y N aaii 3 v (u L t u o c t E c c i 0 t aJ a) } t 'n 0 ° C o t O O O u O y-C U ai 0 O O u al � S v r ` a a in a o 3 — c� ii cn O u W O w CL 6 Z Z /Z V W m Y W W 3 W Y� O LL Q Z 2 O H Z O 2 aJ N 7 u tl0 f9 � L O O C CL L O Y a) T 7 N_ E Q t 4-- +j o ar 4� ar v - _ aJ a) LL in u O O Y O aJ L _ a-+ � Q E tio O in � C L � m v 7 m O ro CL � O (b O) Ea O V N N O N a) O U O) =3 N U c N U ro m L _ N N N > C O O O N 2 w . C E� a) � CL 'ro -E E O m LNL N ro a) CL O 0 C � 3 ro m a� U) N U O 0 U ro N .� a) ro� N ro C p U U 7 m QEn N C C: O U FA C 4+ m L O c O u CJ CL c O C O a u C Z } T a) Q O O` ba C r m a) O. O c O u a) CL IA O a) E C m d fra C C O 13 T u m u. 0 m E r o ro O m rn ?� C E-P O O U N � O N m O U O) L C _N U a) N N N > C U O Oat) =O c d � IL 'ro CD CL Y E O ro LLLL LP m C: a.5 O - Im N c ip 3 ca U U O N U O 7 E N C U ro N a) -0a) lu m m c o U U i a) O y N C O U O r y c � is Y r m C m 7 O r O N r 1A 7 E CaJ C - L m M -0 -0 ro C C C Nu � � O a, CL *' O r E C aJ M '0 aJ 0 O u o c .� a) in C 7 C O r o u w u m r E U d N d O •L L Y to CL ry a1 O IA O C O VI C m T .} v a w m � L E +m+ f0 r a) t a) C r a) M1 C > ate, m v) as a, N w ` O aj O u1 r C `u > O m OIn o ° o m E E _ a u t ° CL Q ,C N N C _ as O 01 L a) C v a) o CL kA kA 00 C m .� m o o LL 41 U a) 41 Q a) CU41 o m LO - 3 m 2 Eu 5 in O C H O OD C 0 C _0 a) O i E W T O N u E a) u v u o a1 � O m e-I V1 C O o o N O r-i C i) •N a) ..0 o v 3 a`, bO i L i ai 3 m > i CO V) o L � � v � � u C O N N N N O a) OD N N Q 3 V) a1 m In 00 O w O u o c (A + =1 E Z a) O m L E O O a) +• r.. LA a) in mIn m a, U -0 u L N u 0 ,N in a a +� kn -0 ro u 0i L � u a) -O u O a�va, -0 i i -C u O C s E c c 3: O (u al v -0 L QJ n Y N —_ 7 N O O c O t o u +, u 41 V) N O L —� t U j C G N i Qj .U) Ll a aU) a o Ln U Li v) O F— u W O ix CL Z Z Z a MW W Y W W W 2 H O.' O U. to Z R O Z O 2 v m U aJ u W m ? T L Ocu Q Y L t T 7 E a r4 4' 041 a1 m IOLO +L+ _N ai a) L a- 0 aj O 4-- O U +, N a L 7 Q � fy0 E to O v1 L s T m J J LaL Z C t C 7 O E Q C O (, G v m Er oa Q) � Id O) 3 Ea 0 0 U w m O N a) O U O cd � 0 y U CD a) n ca L N N N > c O O N 2 N . C CD CL N N O_ _r E O ro � ,a ro 0 a o� 01 � ro 0 3 m m a) � N U 0 7 _0 m C 0 N U en L N ro '+; � m N C c O O t U 7 a� Q Vl N C: c 0 U C O 1p CJ 1A O c O u v CL O i O a u` ul aJ Z aJ CL O CL 04 C Y f0 a7 CL O C O a+ d CL EA C 0 a! E c m a, 41 C C O m !• C al 13 T 'u m v- m_ E r O ro � o ro 3 .5 E'2 0 0 U N N O a) a) O U O) cv -0 c N U .L. ca N a) N >_ C).O 2 al E� m � I w a) n E O INd LNL N r d O .— mZ5 0 ca U a) �z O U)U 0 7 - m O U ro N C a) U) cn ca C p O '- U ro CL N c 0 U 0 N CO C ro 0 c -o aJ E aJ T O N uE .Ln a, (v X a) N vO O aJ � +' C o m C 0 f9 � 'A O In O O C v L 0 N a) a) T - � � f0 aj — CD .In o m a a ICU i (IJ v -0 u C p N N N a, ai Q -0 a) v 3 = a ++ 7 (3) M {N LD O ro cr O m y U O C 1A y 7 -0 7 O Z t 0 i y O ro r 0 aJ +' M1. v y y a) L. m N ` m u -0 u u aJ u aj y Qj 3 `O N t y � C aJ N C L aJ y L aJ LM I Ln 7 v(3ji O 0 C O L C O U ro U cli aj Ln O zQ vOj O p - U a o ^ 7zz ii voi O CORRECTIVE ACTIONS Documentation of any corrective actions taken must be noted and retained with the SWPPP as required by the General VPDES Permit for Discharges of Stormwater from Construction Activities. The operator shall implement corrective actions according to Part II G of the Permit. CORRECTIVE ACTION LOG "Y certify under penalty of law that l have read and understand this document in accordance with the General VPDES Permit for Discharges of Stormwater from Construction Activities. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violat►ons. " Operator or ❑elegated Authority Signature SWPPP Amendment, Modification and Update Log Documentation of SWPPP amendment, modification, or update must be noted and retained with the SWPPP as required by the General VPDES Permit for Discharges of Stormwater from Construction Activities. The operator shall record these actions according to Part II B of the Permit. SWPPP Amendment, Modification and Update Log Date I Description of Amendment, Modification, or Update Responsible Party Responsible Party Responsible Party Responsible Party " l certify under penalty of law that 1 have read and understand this document in accordance with the General VPDFS Permit for Discharges of Stormwater from Construction Activities. 1 am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. " Operator or Delegated Authority Signature