Loading...
HomeMy WebLinkAboutSUB201800171 Review Comments Appeal to BOS 2018-11-16November 16, 2018 Timmons Group Attn: Mr. Craig Kotarski, P.E. 608 Preston Ave. Suite 200 Charlottesville, VA 22903 Re: Lewis and Clark Drive Road Extension Dear Clint: We have reviewed the plans entitled "Lewis and Clark Drive Road Extension," dated September 24, 2018. The following comments need to be addressed. C;PnPral 1. A fire hydrant is required every 1000 feet, proposed locations shown on sheets C4.0-C4.3. 2. An in -line valve is required every 1000 feet, proposed locations shown on sheets C4.0-C4.3. 3. Submit an updated master plan if available. 4. This area will be switching pressure bands in the area in the future. Model the water main extension using the Piney Mountain Pressure Band and the elevation of the new tank will be 770.5, to ensure adequate fire flow for future development. .qhPPt ra n 1. Remove tree from proposed ACSA water easement, as shown on plans. .qhPPt ra 1. ACSA GIS indicates the existing stub -out is 14-inch DIP. Sheet C4.7-C4.9 1. Have water crossings on top of storm. 2. Insulation of water main will be required at open ended storm crossings. If you have any questions concerning this review feel free to call at (434) 977-4511 Ext. 113. Sincerely, Richard Nelson Civil Engineer