Loading...
HomeMy WebLinkAboutSDP201800079 Review Comments Major Amendment, Final Site Plan 2018-12-03 1 County of Albemarle Department of Community Development ________________________________________________________________________ Memorandum To: Craig Kotarski From: Megan Nedostup- Principal Planner Division: Planning Services Date: June 4, 2018 Subject: SDP-2018-016 Keswick Hall Additions- Major Amendment The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approve the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Requirements: 1. The notification fee of $215 has not been paid. The major site plan amendment will not be approved until the fee is paid. 2. [32.5.2(a)] The special use permit (SP2018-001) that will allow these changes has not been approved by the Board of Supervisors to date. The plan will not be approved until the SP is approved. In addition, the special use permit number and any conditions will need to be added to the plan once/if the SP is approved. For the time being, at a minimum add the special use permit number under the zoning. Also, it was discussed with the SP that the laundry and maintenance facility may move locations, if this occurs additional comments may be given during the resubmittal. 3. [32.5.2(a)] Under the zoning information, list ‘Rural Area’ after RA. 4. [32.5.2(a)] Provide the heights of the proposed buildings. 5. [32.5.2(a)] Remove the power plant from the site plan, or add a notation/reference that it is under a different site plan number and bubble that area. 6. [32.5.2(a)] Remove the WPO/VSMP sheets from the site plan. These are not approved with the site plan and are a separate application and approval. 7. [32.5.2(a)] Include the materials legend on all sheets (L1.0-L1.5). 8. [4.17] It is unclear if the light fixtures that are over 3000 lumens are full cut off. It should state that lighting is full cut off to meet the ordinance. a) How many lumens are the bollards? Any fixture that is more than 3000 lumens is required to be full cut off. b) How many lumens are the string lights? Any fixture that is more than 3000 lumens is required to be full cut off. 2 c) Provide the Loss Light Factor for the fixtures- it needs to be set at 1.0. d) Provide the footcandle information on the lighting plan so that it can be determined if the spillover requirements are being met. 9. [32.5.2(d); 4.2] It appears that there are existing critical slopes in the areas that are proposed to be demolished. Show the critical slopes and apply for a critical slopes waiver for Board of Supervisors approval (this is also being requested to be provided with SP2018-001). The justification will need to address the criteria 4.2.5. 10. [32.7.9] Show the grading on the landscape plan. This is needed to verify existing landscaping that will remain and if screening needs to be provided due to the removal of existing landscaping on site. 11. [32.7.9] Provide the parking lot tree required number of trees and provided number of trees information to the landscape sheet. 12. [32.7.9.8] Provide the tree canopy information for all landscaping that is 5’ in height after 10 years. State how much is required vs how much is being provided. 13. [32.7.9.5(e)] Provide landscape screening along the parking lot for the laundry and maintenance building to screen it from Keswick Road. 14. [32.7.9.7] Provide screening of the laundry and maintenance building. 15. [32.5.2(a); 4.12.6] Include the square footage of the restaurant space and all other uses for parking calculations that are outlined in Section 4.12.6. Provide the amount required and provided for all uses. Please contact Megan Nedostup at the Department of Community Development 296-5832 ext. 3004 for further information.