HomeMy WebLinkAboutSDP201800085 Review Comments Final Site Plan and Comps. 2019-01-03Stephen C. Brich, P.E. Commissioner COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper. Virginia 22701 January 3, 2019 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Tim Padalino Re: Vistas at South Pantops — Final Site Plan SDP-2018-00085 Review #1 Dear Mr. Padalino: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Dominion Engineering, dated 26 November 2018, and offers the following comments: 1. This plan does not provide enough detail concerning the proposed improvements to Route 1140. Where are the pavement markings for the right turn lane? What are the dimensions of the turn lane and taper? 2. Please explain the proposed hatching located right of the entrance on Route 1140. The proposed turn lane should tie in to the existing turn lane, making a continuous right -turn lane. 3. A 3 foot buffer strip is required between the curb and sidewalk. 4. All retaining walls that support structures within the right-of-way must be approved by the Culpeper District Structure & Bridge Section. 5. What type of retaining wall is being proposed along Route 1140? How will guardrail posts affect this design, particularly if an MSE wall? 6. The bench behind the guardrail must be at least 4 inches, and, if less than 2 feet, guardrail posts must be 9 feet in length. 7. Provide all applicable VDOT Guardrail Standards (MASH). Show guardrail end sections on plans. S. There appears to be guardrail between the sidewalk and street on some plan sheets; is this just the existing guardrail layer left on? 9. Do the proposed earthwork, retaining wall, and guardrail installation affect the existing 54" culvert? Previous plans showed a connection being made to this culvert; is this no Ionger the case? 10. What is the hatched area along the proposed sidewalk/guardrail? 11. The proposed crosswalk markings do not appear to be warranted. Please see IIM-TE-384. 12. Street trees cannot be located within 30 feet of the entrance radii. 13. Provide the VDOT WP-2 detail and note on the plans the required area of mill and overlay in accordance with the WP-2 standard. 14. Is Structure 1 I a DI as noted on the profile? It does not appear as a DI in plan view. VirginiaDOT.org WE KEEP VIRGINIA MOVING January 3, 2019 Tim Padalino Page 2 15. CG-12's should be oriented perpendicular to the crossing street (entrance). 16. Provide entrance radii. Please provide two copies of the revised plan along with a comment response letter. If further information is desired, please contact Justin Deel at 434-422-9894. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the Charlottesville Residency Transportation and Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, wut- K/ MA --- Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency VirginiaDOT.org WE KEEP VIRGINIA MOVING