Loading...
HomeMy WebLinkAboutSDP201800085 Review Comments Final Site Plan and Comps. 2018-12-17December 17, 2018 Roudabush, Gale and Associates, Inc. Attn: Mr. Jimmy Taggart, P.E. 914 Monticello Road Charlottesville, VA 22902 Re: The Vistas at South Pantops Dear Jimmy: We have reviewed the plans entitled "The Vistas at South Pantops," dated November 26, 2018. The following comments need to be addressed. General 1. Provide fixture counts for the buildings. This will determine the water meter size. 2. Provide water and sewer data sheets with the next submission. 3. Remove the following sheets from ACSA submission: 9-13, 16 and 20. Sheet 6 1. Show existing sewer main. 2. Call out pipe diameter, material, and fittings. 3. Show gate valves, as shown on plans. 4. Add a fire hydrant as shown on plans and relocate FDC as shown on plans. 5. Relocate water main going to the last hydrant, as shown on plans. Sheet 7 1. Remove portion of proposed retaining wall out of ACSA sewer easement. 4hPPt R 1. Remove proposed landscaping from ACSA easements, as shown on plan. 2. ACSA does not own the fire line passed the gate valve. Refer to plans regarding our easement. Sheet 15 1. It appears MH 2B is above grade, but also appears to be in the parking lot. 2. The proposed grade elevation is not connected between MH 2D_2C. If you have any questions concerning this review feel free to call at (434) 977-4511 Ext. 113. Sincerely, Richard Nelson Civil Engineer