HomeMy WebLinkAboutSDP201800077 Review Comments Minor Amendment 2019-01-10County of Albemarle
Department of Community Development
Memorandum
To: Collins Engineering c/o Mr. Scott Collins, PE (scottgcollins-en ing eering com)
From: Tim Padalino, AICP — Senior Planner
Division: Planning Services
Date: January 10, 2019
Subject: Review Comments for SDP201800077 (Crozet Park Phase III Athletic Fields — Minor Amendment) —
2"d Review Comment Letter
The above -referenced minor site plan amendment (dated 10/15/2018) has been reviewed by the Planning Services
Division of the Albemarle County Department of Community Development (CDD).
The site plan is not acceptable per applicable Albemarle County Code, and is not approved at this time. The Planner
for CDD will approve the plan referred to above when the following items have been satisfactorily addressed. The
following comments are those that have been identified at this time; additional comments or conditions may be
added or eliminated based on further review. [Comments are preceded by the applicable reference to the Albemarle
County Code Chapter 18 — Zoning Ordinance (Z.O.).]
Albemarle County Planning Services (Planning): Tim Padalino (tpadalino(c�r�albemarle.org) — Requested Changes
1. [Z.O. Sections 10.4, 4.10, and 4.171: Light poles are subject to applicable area and bulk regulations,
including maximum structure height regulations. Maximum structure height is thirty-five (35) feet in
the Rural Areas (RA) zoning district. Therefore, the proposed light poles shown with a height of
seventy (70) feet are not permissible, unless a modification is applied for and granted pursuant to
Division 5 of Z.O. Section 33 (generally) and Z.O. Sections 4.10.3.2(b) and 4.17.5(a)(3) (specifically).
Please submit a Special Exception request to modify the maximum permissible structure height for the
proposed outdoor athletic lighting poles.
Comment #1 update (1/10/19): The Albemarle County Board of Supervisors (BOS) approved the
Special Exception request to modify (increase) the maximum permissible height for proposed poles
supporting outdoor luminaires at an athletic facility. This BOS approval permits the light poles to be
installed at the proposed height as shown on the plans.
However, a note must be added to identify the BOS-approved Special Exception request and to list the
condition(s) of approval; please see comment #3 (below).
2. [Z.O. Sections 4.17.2(a), 4.17.4(a), and 4.17.5(a)(2)1: Luminaires used on outdoor athletic lighting
poles are subject to the full -cutoff requirements specified in Z.O. Section 4.17.4. Therefore, the
proposed luminaires from Musco Lighting are not permissible, unless a modification is applied for and
granted pursuant to Division 5 of Z.O. Section 33 (generally) and Z.O. Section 4.17.5(a)(2)
(specifically). Please submit a Special Exception request to modify or waive the applicable standards
requiring the use of full -cutoff luminaires on the proposed outdoor athletic lighting poles.
Comment #2 update (1/10/19): The Albemarle County BOS approved the Special Exception request
to waive the outdoor lighting standards requiring the use of full cutoff luminaires for the proposed
1 of 2
outdoor lighting at an athletic facility. This BOS approval permits the use of the proposed luminaires as
shown on the application materials (Musco data sheets) provided via email on 12/14/2018 (attached for
reference).
However, a note must be added to identify the BOS-approved Special Exception request and to list the
condition(s) of approval; please see comment #3 (below).
3. [Special Exceptions approved 1/9/20191: The Albemarle County BOS approval of the Special
Exception requests for outdoor athletic lighting for the Crozet Park athletic facility included three
conditions of approval. The following notes must be added to the Cover Sheet (Sheet 1) of SDP-2018-
00077:
The Albemarle County Board of Supervisors approved (with conditions) two Special Exception
requests for Tax Map Parcel 056A2-01-00-072A0 (Crozet Park) on January 9, 2019. The approved
Sepcial Exceptions waived the outdoor lighting standards requiring the use of full cutoff luminaires
for the proposed outdoor lighting at an athletic facility, and modified (increased) the maximum
permissible height for proposed poles supporting outdoor luminaires at an athletic facility. This
approval is subject to the following Special Exception Conditions:
1. The maximum permissible height of the poles supporting outdoor luminaires at the Crozet
Park athletic facility shall be seventy (70) feet.
2. Outdoor lighting of the Crozet Park athletic facility shall not continue past 10:00 p.m.
3. All outdoor lighting shall meet the specifications identified in the data sheets for the light
structure system and the luminaire and driver included in the application materials submitted
by Collins Engineering under letter dated November 5, 2018, regarding Claudius Crozet Park
Phase III Athletic Field Improvements (Lighting Plan) — Request for Special Exception,
Exception Request for modification to max height of lighting & full cutoff luminaries.
4. [Z.O. Sections 32.5.2(n) and Z.O.32.6.2(k)]: The outdoor lighting specifications (Musco data sheets)
contained in the application materials provided via email on 12/14/2018 (attached for reference) must
be added to SDP-2018-00077.
Please contact Tim Padalino at the Department of Community Development at (434)-296-5832 ext. 3088 or
tpadalino(kalbemarle.org for further information or assistance. Thank you.
2 of 2
Luminaire and Driver Components - TLC-BT 575
/ Luminaire Data
Weight (luminaire)
r
UL listing number
UL Listed for USA / Canada
Ingress protection, luminaire
Material and finish
34 lb (15 kg)
E338094
UL1598 CSA-C22.2
No.250.0
I P65
Aluminum,
powder -coat painted
Wind speed rating (aiming only) 150 mi/h (67 m/s)
Photometric Characteristics
Projected lumen maintenance per IESTM-21-11
L90 (13.5k)
>81,000 h
L80 (13.5k)
>81,000 h
L70 (13.5k)
>81,000 h
CIE correlated color temperature
5700 K
Color rendering index (CRI)
75 typ, 70 min
Lumens'
52,000
Footnotes:
1) Incorporates appropriate dirt depreciation factor for life of luminaire.
All components from foundation to poletop are designed to
work together in Light -Structure System"" to ensure reliable,
trouble -free operation.
OCXO U.S. and foreign patent(s) issued and pending • @2017, 2018 Musco Sports Lighting, LLC • TLC-BT-575 5700K 75CRI • M-2477-en04-3
musco®
1
Luminaire and Driver Components - TLC-BT-575
Driver Data
Electrical Data
Rated wattage'
Per driver 575 W
Per luminaire 575 W
Number of luminaires per driver 1
Starting (inrush) current <40 A, 256 ps
Fuse rating 15 A
UL, IEC ambient temperature rating, 50°C (1227)
electrical components enclosure
Ingress protection, IP54
electrical components enclosure
Efficiency 95%
Typical Wiring
Surge'
protection
Controller ; Luminaire
L1 Disconnect Fuse ( (it present_)
Driver
L2* Fuse
* If L2 (conn) is neutral then not switched or fused.
t Not present if indoor installation.
Max operating current 3.48 A 3.35 A 3.16 A 3.03 A 2.90 A 2.51 A 2.01 A 1.83 A 1.74 A 1.68 A 1.45 A
per luminaire
Footnotes:
1) Rated wattage is the power consumption, including driver efficiency losses,
at stabilized operation in 25°C ambient temperature environment.
2) Operating current includes allowance for 0.90 minimum power factor,
operating temperature, and LED light source manufacturing tolerances.
Notes
1. Use thermal magnetic HID -rated or D-curve circuit breakers.
2. See Musco Control System Summaryfor circuit information.
16.00 in
21.00 in (406 mm)
(533 mm)
19.00 in
(483 mm)
26.00 in
(660 mm)
0= U.S. and foreign patent(s) issued and pending • @2017, 2018 Musco Sports Lighting, LLC • TLC-BT-575 5700K 75CRI • M-2477-en04-3
musco®
Pa
17.00 in
(432 mm)
21.00 in
(533 mm)
0
Luminaire Data
Weight (luminaire)
80 lb (36 kg)
UL listing number
E338094
UL listed for USA / Canada
UL1598 CSA-C22.2
No.250.0
Ingress protection, luminaire
IP65
Material and finish
Aluminum, powder -coat
painted
Wind speed rating (aiming only)
150 mi/h (67 m/s)
UL ambient temperature rating,
500C (122°F)
luminaire
Photometric Characteristics
Projected lumen maintenance per
IESTM-21-11
L90 (13.5k)
>81,000 h
L80 (13.5k)
>81,000 h
L70 (13.5k)
>81,000 h
CIE correlated color temperature
5700 K
Color rendering index (CRI)
75 typ, 70 min
Lumens'
121,000
Footnotes:
1) Incorporates appropriate dirt depreciation factor for life of luminaire
COU.S. and foreign patent(s) issued and pending • 02016, 2018 Musco Sports Lighting, LLC • TLC-LED-1150 5700K 75 CRI • M-2209-en04-7
musco
1
Driver Data
Electrical Data
Rated wattage'
Per driver
1150 W
Per luminaire
1150 W
Number of luminaires per driver
1
Starting (inrush) current
<40 A, 256 µs
Fuse rating
UL, IEC ambient temperature rating,
electrical components enclosure
Ingress protection, electrical
components enclosure
15 A
500C (1220F)
IP54
Efficiency
95%
Dimming mode
optional
Range, energy consumption
20 — 100%
Range, light output
25 — 100%
Max operating current per 7.11 A 6.83 A 6.46 A 6.18 A
luminaire
1
Footnotes:
1) Rated wattage is the power consumption, including driver efficiency losses,
at stabilized operation in 25°C ambient temperature environment.
2) Operating current includes allowance for 0.90 minimum power factor,
operating temperature, and LED light source manufacturing tolerances.
Notes
1. Use thermal magnetic HID -rated or D-curve circuit breakers.
2. See Musco Control System Summary for circuit information.
Typical Wiring
Surget
protection
---------------
Controller
Disconnect (if present) I
L1 Fuse -- -- - +
�—T— Driver
L2~ Fuse Luminaire
* If L2 (com) is neutral then not switched or fused.
t Not present if indoor installation.
5.92A 5.13A 4.10A 3.74A 3.56A 3.43A 2.96A
COU.S. and foreign patent(s) issued and pending • (02016, 2018 Musco Sports Lighting, LLC • TLC-LED-1150 5700K 75 CRI • M-2209-en04-7
musco