HomeMy WebLinkAboutSDP201800077 Review Comments Minor Amendment 2019-01-10County of Albemarle Department of Community Development Memorandum To: Collins Engineering c/o Mr. Scott Collins, PE (scottgcollins-en ing eering com) From: Tim Padalino, AICP — Senior Planner Division: Planning Services Date: January 10, 2019 Subject: Review Comments for SDP201800077 (Crozet Park Phase III Athletic Fields — Minor Amendment) — 2"d Review Comment Letter The above -referenced minor site plan amendment (dated 10/15/2018) has been reviewed by the Planning Services Division of the Albemarle County Department of Community Development (CDD). The site plan is not acceptable per applicable Albemarle County Code, and is not approved at this time. The Planner for CDD will approve the plan referred to above when the following items have been satisfactorily addressed. The following comments are those that have been identified at this time; additional comments or conditions may be added or eliminated based on further review. [Comments are preceded by the applicable reference to the Albemarle County Code Chapter 18 — Zoning Ordinance (Z.O.).] Albemarle County Planning Services (Planning): Tim Padalino (tpadalino(c�r�albemarle.org) — Requested Changes 1. [Z.O. Sections 10.4, 4.10, and 4.171: Light poles are subject to applicable area and bulk regulations, including maximum structure height regulations. Maximum structure height is thirty-five (35) feet in the Rural Areas (RA) zoning district. Therefore, the proposed light poles shown with a height of seventy (70) feet are not permissible, unless a modification is applied for and granted pursuant to Division 5 of Z.O. Section 33 (generally) and Z.O. Sections 4.10.3.2(b) and 4.17.5(a)(3) (specifically). Please submit a Special Exception request to modify the maximum permissible structure height for the proposed outdoor athletic lighting poles. Comment #1 update (1/10/19): The Albemarle County Board of Supervisors (BOS) approved the Special Exception request to modify (increase) the maximum permissible height for proposed poles supporting outdoor luminaires at an athletic facility. This BOS approval permits the light poles to be installed at the proposed height as shown on the plans. However, a note must be added to identify the BOS-approved Special Exception request and to list the condition(s) of approval; please see comment #3 (below). 2. [Z.O. Sections 4.17.2(a), 4.17.4(a), and 4.17.5(a)(2)1: Luminaires used on outdoor athletic lighting poles are subject to the full -cutoff requirements specified in Z.O. Section 4.17.4. Therefore, the proposed luminaires from Musco Lighting are not permissible, unless a modification is applied for and granted pursuant to Division 5 of Z.O. Section 33 (generally) and Z.O. Section 4.17.5(a)(2) (specifically). Please submit a Special Exception request to modify or waive the applicable standards requiring the use of full -cutoff luminaires on the proposed outdoor athletic lighting poles. Comment #2 update (1/10/19): The Albemarle County BOS approved the Special Exception request to waive the outdoor lighting standards requiring the use of full cutoff luminaires for the proposed 1 of 2 outdoor lighting at an athletic facility. This BOS approval permits the use of the proposed luminaires as shown on the application materials (Musco data sheets) provided via email on 12/14/2018 (attached for reference). However, a note must be added to identify the BOS-approved Special Exception request and to list the condition(s) of approval; please see comment #3 (below). 3. [Special Exceptions approved 1/9/20191: The Albemarle County BOS approval of the Special Exception requests for outdoor athletic lighting for the Crozet Park athletic facility included three conditions of approval. The following notes must be added to the Cover Sheet (Sheet 1) of SDP-2018- 00077: The Albemarle County Board of Supervisors approved (with conditions) two Special Exception requests for Tax Map Parcel 056A2-01-00-072A0 (Crozet Park) on January 9, 2019. The approved Sepcial Exceptions waived the outdoor lighting standards requiring the use of full cutoff luminaires for the proposed outdoor lighting at an athletic facility, and modified (increased) the maximum permissible height for proposed poles supporting outdoor luminaires at an athletic facility. This approval is subject to the following Special Exception Conditions: 1. The maximum permissible height of the poles supporting outdoor luminaires at the Crozet Park athletic facility shall be seventy (70) feet. 2. Outdoor lighting of the Crozet Park athletic facility shall not continue past 10:00 p.m. 3. All outdoor lighting shall meet the specifications identified in the data sheets for the light structure system and the luminaire and driver included in the application materials submitted by Collins Engineering under letter dated November 5, 2018, regarding Claudius Crozet Park Phase III Athletic Field Improvements (Lighting Plan) — Request for Special Exception, Exception Request for modification to max height of lighting & full cutoff luminaries. 4. [Z.O. Sections 32.5.2(n) and Z.O.32.6.2(k)]: The outdoor lighting specifications (Musco data sheets) contained in the application materials provided via email on 12/14/2018 (attached for reference) must be added to SDP-2018-00077. Please contact Tim Padalino at the Department of Community Development at (434)-296-5832 ext. 3088 or tpadalino(kalbemarle.org for further information or assistance. Thank you. 2 of 2 Luminaire and Driver Components - TLC-BT 575 / Luminaire Data Weight (luminaire) r UL listing number UL Listed for USA / Canada Ingress protection, luminaire Material and finish 34 lb (15 kg) E338094 UL1598 CSA-C22.2 No.250.0 I P65 Aluminum, powder -coat painted Wind speed rating (aiming only) 150 mi/h (67 m/s) Photometric Characteristics Projected lumen maintenance per IESTM-21-11 L90 (13.5k) >81,000 h L80 (13.5k) >81,000 h L70 (13.5k) >81,000 h CIE correlated color temperature 5700 K Color rendering index (CRI) 75 typ, 70 min Lumens' 52,000 Footnotes: 1) Incorporates appropriate dirt depreciation factor for life of luminaire. All components from foundation to poletop are designed to work together in Light -Structure System"" to ensure reliable, trouble -free operation. OCXO U.S. and foreign patent(s) issued and pending • @2017, 2018 Musco Sports Lighting, LLC • TLC-BT-575 5700K 75CRI • M-2477-en04-3 musco® 1 Luminaire and Driver Components - TLC-BT-575 Driver Data Electrical Data Rated wattage' Per driver 575 W Per luminaire 575 W Number of luminaires per driver 1 Starting (inrush) current <40 A, 256 ps Fuse rating 15 A UL, IEC ambient temperature rating, 50°C (1227) electrical components enclosure Ingress protection, IP54 electrical components enclosure Efficiency 95% Typical Wiring Surge' protection Controller ; Luminaire L1 Disconnect Fuse ( (it present_) Driver L2* Fuse * If L2 (conn) is neutral then not switched or fused. t Not present if indoor installation. Max operating current 3.48 A 3.35 A 3.16 A 3.03 A 2.90 A 2.51 A 2.01 A 1.83 A 1.74 A 1.68 A 1.45 A per luminaire Footnotes: 1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25°C ambient temperature environment. 2) Operating current includes allowance for 0.90 minimum power factor, operating temperature, and LED light source manufacturing tolerances. Notes 1. Use thermal magnetic HID -rated or D-curve circuit breakers. 2. See Musco Control System Summaryfor circuit information. 16.00 in 21.00 in (406 mm) (533 mm) 19.00 in (483 mm) 26.00 in (660 mm) 0= U.S. and foreign patent(s) issued and pending • @2017, 2018 Musco Sports Lighting, LLC • TLC-BT-575 5700K 75CRI • M-2477-en04-3 musco® Pa 17.00 in (432 mm) 21.00 in (533 mm) 0 Luminaire Data Weight (luminaire) 80 lb (36 kg) UL listing number E338094 UL listed for USA / Canada UL1598 CSA-C22.2 No.250.0 Ingress protection, luminaire IP65 Material and finish Aluminum, powder -coat painted Wind speed rating (aiming only) 150 mi/h (67 m/s) UL ambient temperature rating, 500C (122°F) luminaire Photometric Characteristics Projected lumen maintenance per IESTM-21-11 L90 (13.5k) >81,000 h L80 (13.5k) >81,000 h L70 (13.5k) >81,000 h CIE correlated color temperature 5700 K Color rendering index (CRI) 75 typ, 70 min Lumens' 121,000 Footnotes: 1) Incorporates appropriate dirt depreciation factor for life of luminaire COU.S. and foreign patent(s) issued and pending • 02016, 2018 Musco Sports Lighting, LLC • TLC-LED-1150 5700K 75 CRI • M-2209-en04-7 musco 1 Driver Data Electrical Data Rated wattage' Per driver 1150 W Per luminaire 1150 W Number of luminaires per driver 1 Starting (inrush) current <40 A, 256 µs Fuse rating UL, IEC ambient temperature rating, electrical components enclosure Ingress protection, electrical components enclosure 15 A 500C (1220F) IP54 Efficiency 95% Dimming mode optional Range, energy consumption 20 — 100% Range, light output 25 — 100% Max operating current per 7.11 A 6.83 A 6.46 A 6.18 A luminaire 1 Footnotes: 1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25°C ambient temperature environment. 2) Operating current includes allowance for 0.90 minimum power factor, operating temperature, and LED light source manufacturing tolerances. Notes 1. Use thermal magnetic HID -rated or D-curve circuit breakers. 2. See Musco Control System Summary for circuit information. Typical Wiring Surget protection --------------- Controller Disconnect (if present) I L1 Fuse -- -- - + �—T— Driver L2~ Fuse Luminaire * If L2 (com) is neutral then not switched or fused. t Not present if indoor installation. 5.92A 5.13A 4.10A 3.74A 3.56A 3.43A 2.96A COU.S. and foreign patent(s) issued and pending • (02016, 2018 Musco Sports Lighting, LLC • TLC-LED-1150 5700K 75 CRI • M-2209-en04-7 musco 2