Loading...
HomeMy WebLinkAboutSDP201800091 Review Comments Final Site Plan and Comps. 2019-02-07COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 Site Plan Amendment Review Project title: Oakleigh — Minor Site Plan Amendment Project file number: SDP201800091 Plan preparer: Steve Edwards [steve(&edwarddesignstudio.com] 4936 Old Boonesboro Road, Lynchburg VA 24503 Alan Franklin, P.E., LLC [alan(a)alanfranklinpe.com] 427 Cranberry Lane, Crozet VA 22932 Owner or rep.: Oakleigh Albemarle LLC — 690 Berkmar Circle / Charlottesville, VA 22901 Plan received date: 20 Dec 2018 Date of comments: 7 Feb 2019 Plan Coordinator: Paty Saternye Reviewer: John Anderson SDP201800091 Compare approved impervious area (224,639 ft2) with proposed Amendment (232,586 ft2); a slight 3.4% increase. Amend VSMP/WPO Plan for this site plan, including VSMH Vol. 2 Appendix 5D worksheets. (Note: proposed routing of paved surface runoff directly into a Level-1 biofilter requires pre-treatment) Link: https://www.deq.virgi>� nia.gov/Portals/O/DEQ/Water/Publications/HndbkVolumeI.pdf - p. 3.11-14 and FIG. 3.11-7. "Like other infiltration basins, bioretention basins must always be preceded by a pretreatment facility to remove grease, oil, floatable organic material, and settleable solids..." SDP201700005, Sheet 2: BREAKDOWN: BUILDINGS: 1.3 21% ROADS rSIDEWALKS: ("75.1324 PAVED PARKINGlROADS 121,505 2.79 32% SIDEWALKS: 23,210 0.53 6 PERVIOUS AREAIOPEN SPACE: is 3.67 42% TOTAL SITE ACREAGE: 384,286 8.822 100°111 NOTES: ` 1 1. The minimum required open space is 20 % (per Section 20A.9.a.1 ), 1V� 2. Pervious area'Open Space includes land within ROW and on any indivicual lot. `.'o 3. Common open space excludes land within ROW and on individual lots. 4. Lots Include only those indi dual lots and nothing more. 2. Include reference to approved VSMP/WPO for Oakleigh: list WP0201700023, Approved 3/26/18, as an associated plan. Sheet 4 3. Provide gutter along Eckerson Court, from Int. with Nichols Court, to parking area entrance at proposed apartments. Ref. 18-4.12.15.g. Label curb and gutter using VDOT nomenclature, CG-7, for example. Engineering Review Comments Page 2 of 3 4. Concrete dumpster pad does not appear to extend 8' from back face of enclosure gates to edge of asphalt surface. Revise to obtain min. 8' length, measured from back face of enclosure gates to edge of asphalt. Ref. 18-4.12.19. 5. Dimension Eckerson Court travelway width. Provide width label. 6. Revise Note 5., Restrictions/Requirements/Notes: to read `All travelways are private with public access easements over them.' 7. Label emergency access concrete apron /entrance at Rio Road using VDOT nomenclature (CG-9a, for example). Ref. Final Site Plan checklist, pg. 2, entrances and right-of-way improvements. 8. SDP201700005, Oakleigh - Major Site Plan Amendment does not appear to include retaining wall design. Provide retaining wall design. See Final Site Plan and Retaining Wall checklists (attached to this Memo). 9. Provide L X W (Typ.) dimensions for the three proposed parking spaces just west of the emergency access. 10. Provide auto turn for typical passenger vehicles at Sta. 12+50f, Eckerson Ct, to show that a car exiting may pass a car entering without striking curb or parked vehicles, with at least 2' clearance between vehicles. Revise design to provide minimum 2' clearance between two typ. passenger vehicles at this location. 11. Label travelway width between Sta. 12+50(f) and dumpsters, Eckerson Court (appears to be -14' FC-FC). 12. This section of travelway is too narrow for two-way travel. Provide signs indicating `one-way' travel unless inconsistent with site plan requirements or Albemarle County Planning Division review, or policy. 13. Provide auto -turn for waste management vehicle (Typ.) to illustrate how WM vehicles may perform reverse movement to exit this area without striking pedestrians, curbs, or parked vehicles. 14. Revise subterranean parking drive aisle dimension to 24' (apparent typo). 15. Revise 9' w (non-HC) parking space (adjacent to 8' w HC space) to 10' width. Ref. 18-4.12.16.c.1. 16. Label sidewalk width, for walk located north of Eckerson Court. 17. Provide curb cut required for drainage to bioretention midway along 8 parking spaces south of apartments. 18. Provide bioretention basin pre-treatment for this (asphalt surface) storm runoff, item above. 19. Provide `do not enter' sign at south exit of subterranean parking. Alternatively, revise travelway width, north side of apartments to 20', min. Ref. 18-4.12.17.c.1.-2. Sheet 5 20. Provide storm inlets and conveyance from paved surface of Eckerson Court. Please ref. proposed profile. From proposed H.P. Sta. 11+20, surface runoff flows west, without any inlets on the travelway. This runoff bypasses the parking area fronting east side of proposed apartments, and washes into a dumpster enclosure. Provide VDOT storm drainage design, for both culvert pipes and inlets. Eckerson may (likely will) flood and present hazard under proposed curb without gutter and inlet design. 21. Revise I/8 (4" curb) detail to VDOT CG-7. Ref. 2016 Road and Bridge Standard, CG-7, 201.04, Rev. 9/06. 22. Provide dumpster pad detail. Ref. 18-4.12.19. Specify /provide minimum 4" stone base, 6" concrete depth, 3000psi at 28 days, with minimum grid of wire reinforcing or #4 bars at 12" on center. Final Site Plan checklist, p. 3, parking and circulation, item 8. 23. Revise proposed grade so that Eckerson Court storm runoff does not wash through dumpster pad enclosure. Collect and convey storm runoff to avoid spread greater than 'h travel lane width + gutter pan. Sheet 8: 24. Revise Ksag value, Eckerson Court, PVI Sta. 12+46 (K proposed = 5.00) to nearly approximate approved site plan Ksag PVI Sta. 12+86, K=12.00. Recommend Ksag = 15.00 as a design target. 25. Provide emergency access section (detail). 26. Provide grasspave detail. 27. Detail D/8: Include VDOT Class A3 General concrete design parameters; i.e., compressive strength, slump, air, etc. Link: http://www.virginiadot.ora/VDOTBusiness/asset_Oload_file41_3529.pdf , p. C-18. 28. Provide SL Storey Streetguard (guardrail) detail, as well as technical information that demonstrates this product is equivalent to VDOT Std. in terms of barrier protection. 29. Nichols Court, Sta. 11+00(f): provide cross drain (VDOT CD-1, 2) at cut/fill transition. 30. Note: An approved VSMP Plan Amendment is required prior to Site Plan Amendment approval. Engineering Review Comments Page 3 of 3 Please feel free to call if any questions. Thank you J. Anderson 434.296-5832 -0069 SDP201800091 Oakleigh Minor 020719.docx