Loading...
HomeMy WebLinkAboutSDP201900001 Review Comments Initial Site Plan 2019-02-21COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 February 21, 2019 Mitch Bowser, P.E. Timmons Group 1001 Boulders Parkway, Suite 300 Richmond, VA 23225 mitchell.bowserna.timmons. com RE: SDP201900001 Berkmar Drive Apartments — Initial Site Plan Dear Mr. Bowser: The Site Review Committee has reviewed the development proposal referenced above. Initial comments from the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Planning Services (Planner) Albemarle County Engineering Services (Engineer) (attached) Albemarle County Information Services (E911) Albemarle County Building Inspections (attached) Albemarle County Department of Fire Rescue Albemarle County Service Authority (attached) Virginia Department of Transportation (attached) Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that will be required to be resolved prior approval of the major site plan amendment Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, Ltt, Cameron Langille Senior Planner Albemarle County Planning Services (Planner) — Cameron Langille, blan ille =,albemarle.org — Required changes: Comments to Be Addressed Prior to Initial Site Plan Approval: [General Comment] Prior to initial site plan approval, the zoning violation pertaining to the recreation areas required by the County for the mobile home park north of this site must be rectified. The site plan for the mobile home park showed the required recreation amenities being installed on TMP 32-53 and 32-54. However, these features were never installed. New development applications for developments on TMPs 32-53, 32-54, and 32- 55 cannot be approved by the County until this violation is resolved. A letter of revision is currently under review with the County to address this issue. Comments have been sent to the applicant, but the County is awaiting a final response. 2. [30.2.61 The project lies within the Airport Impact Area (AIA) Overlay Zoning District. Prior to approval of the initial site plan, the Albemarle County Planning Commission must determine that the proposed bonus level cluster multifamily development will reduce or be equivalent to hazard and/or noise impacts anticipated under standard level -conventional development of the underlying zoning district. a. A tentative date for the Planning Commission meeting has been set for March 19, 2019. The applicant should request a deferral so that the PC can act on the proposal. 3. [4.16.1] The site plan does not demonstrate compliance with the minimum recreation standards required for developments proposing more than 30 units at a density of more than 4 du/acre. A minimum of two hundred (200) square feet per unit of recreational area shall be provided in common area or open space on the site, this requirement not to exceed five (5) percent of the gross site area. The following facilities must be provided in the recreation areas: a. [4.16.2.1] One(]) tot lot shall be provided for the first thirty (30) units and for each additional fifty (50) units. A total of six (6) tot lots must be provided within proposed recreation areas. Each tot lot must measure at least 2,000 sq. ft. and shall be fenced. A total of 12,000 square feet of tot lot recreation area must be provided within the project. Each tot lost must contain the following equipment: i. One (1) swing (four (4) seats); ii. One (1) slide; iii. Two (2) climbers; iv. One (1) buckabout or whirl; v. Two (2) benches. b. [4.16.2.2] One-half (112) court for basketball shall be provided for each one hundred (100) units. Each basketball court must consist of a thirty (30) foot by thirty (30) foot area of four (4) inch 21-A base and one and one half (1 112) inches bituminous concrete surface, and a basketball backboard and net installed at regulation height. A total of 1.5 basketball courts meeting the minimum sizes must be provided. c. Calculations identifying the minimum recreation facilities required must be provided on the site plan. This includes the total quantity of tot lot equipment, and the total number of 1.5 basketball courts. d. The recreation areas must be shown on all applicable drawings and comply with the equipment and size standards specified in Section 4.16.1 of the Zoning Ordinance. e. Detail cut sheets for the basketball courts and tot lot equipment must be provided in the construction details on the site plan. f. [4.16.3] The following notes must be added to the site plan: i. "Recreational equipment and facilities shall be maintained in a safe condition and replaced as necessary. Maintenance shall be the responsibility of the property owner if rental units or a homeowners' association if sale units." ii. "Recreational facilities shall be completed when fifty (50) percent of the units have received certificates of occupancy." 4. [32.5.2 (a)] The setbacks shown on the drawing are incorrect. There is no 20' setback in the R-15 zoning district (this includes front, side and rear). The maximum front setback is "25 feet from the right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way." The front setback should be applied on the eastern development boundary, which means Building 7 currently does not meet the maximum front setback. Building 7 will need to be moved closer to property lines to comply with the setback. a. At least one building must comply with the minimum and maximum front setback. Staff suggests reversing the location of building 7 and the row of parking east of Building 7. This will move the building closer to the property line to comply with the maximum 25' front setback. Comments to Be Addressed Prior to Final Site Plan Approval: 1. [32.5.2 (a)] Change the proposed use to "Bonus Level Cluster Development — Multifamily Dwellings" on Sheet C0.0. 2. [32.5.2 (a)] Remove Note 22 from Sheet C0.0. Landscaping calculations should be shown on the landscape plans. 3. [32.5.2 (a)] Please state the full Tax Map Parcel (TMP) numbers for all parcels within the development in Note 5 on Sheet C0.0. a. Please be aware that boundary line adjustment applications have been submitted to the County for review and approval related to this project. Prior to final site plan approval, the TMP numbers may need to be revised so that the plans accurately identify all properties that are within the project boundary. 4. [32.5.2 (a)] Prior to final site plan approval, a boundary line adjustment application must be submitted, reviewed, approved, and recorded that combines TMPs 32-55, 32-54, and the RA Rural Area zoned portion of TMP 32-52 into a single parcel of record that measures 17.4 acres. 5. [32.5.2 (a)] Prior to final site plan approval, please update Note 24 on Sheet C0.0 so that it states the source of the topographic information/survey used on the plans. 6. [32.5.2 (a)] Please add a note to Sheet C0.0 that states the instrument numbers (deed book and pages) for all recorded plats and deeds associated each parcel within the development. 7. [32.5.2 (a)] Add the primary zoning district to the property labels for all adjacent parcels shown on the plans. 8. [32.5.2 (a)] See Engineering Division comments regarding the cemetery located at the southwest corner of "Parcel C." Parcel C appears to be the property currently known as TMP 32-53. See the recorded plat from Deed Book 5107, pages 617-620 for a survey of the cemetery location. Provide information that the necessary precautions required by law will be taken to avoid disturbances and preserve human remains. 9. [32.5.2 (a)] Please state the application numbers of all approved Special Use Permit and Zoning Map Amendments (ZMA) that apply to the development in Note 7 on Sheet C0.0. a. TMPs 03200-00-00-05500, 03200-00-00-05400, and 03200-00-00-05300 are subject to the proffers associated with ZMA199200014. b. TMPs 03200-00-00-05500, 03200-00-00-05400, and 03200-00-00-05300 are subject to the conditions of Special Use Permits SP199300013 and SP199500025. c. Please add all pages of the approved Action Letter from SP 199500025 as an exhibit on Sheet C 1.0. 10. [32.5.2 (a)] The proposed development appears to propose adding a portion of the existing TMP 32-52 (identified as "Parcel D" on Sheet C2.0) to the boundaries of the project. TMP 32-52 is zoned RA Rural Areas. The Zoning notes on Sheet C0.0 will need to state the acreage of RA land within the project. 11. [32.5.2 (a)] Please state all applicable Overlay Zoning Districts that apply to parcels within the development in Note 7 on Sheet C0.0. a. The project is within the AIA -Airport Impact overlay Zoning District. b. There are areas of Managed and Preserved Steep Slopes Overlay District within the boundaries of the development. These should be listed in Note 7, and shown on all applicable drawings where visible. 12. [32.5.2 (a)] Add a note to Sheet C0.0 stating the minimum and maximum building and garage setback lines, and building separation requirements as specified in Section 4.19 of the Zoning Ordinance. This development is classified as non-infill and is subject to the following setbacks: a. Front Minimum (building): 5 feet from the right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way; b. Front Maximum (building): 25 feet from the right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way; c. Side Minimum: None; see Non-Infill Building Separation. d. Side Maximum: None. e. Rear Minimum: 20 ft. f. Rear Maximum: None. g. Front Minimum (off-street parking and loading spaces): Front loading garage: 18 feet from the right-of- way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way. Side loading garage: 5 feet from the right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way. h. Building Separation — Minimum: 10 feet, unless the building shares a common wall; provided that in the R-10 and R-15 districts if the abutting lot is zoned residential other than R-10 and R-15, rural areas, or the Monticello Historic district, any building that exceeds 35 feet in height shall be separated from any other building by 10 feet plus one foot for each foot the building exceeds 35 feet in height 13. [32.5.2 (a)] Add a note to Sheet C0.0 stating the R-15 District height regulations, in accordance with Section 18.8 of the Zoning Ordinance. a. Maximum structure height: 65' b. The minimum stepback requirements for any story that begins above forty (40) feet in height or for each story above the third story, whichever is less, in height shall be as provided in section 4.19. 14. [32.5.2 (a)] Please show the correct minimum and maximum building and parking setback lines on Sheets C4.0 through C4.3 a. Setback lines should state whether each line is a front, side, or rear setback. Labels should also state whether each setback is a minimum or maximum setback line. 15. [32.5.2 (a)] The setback lines shown on Sheets C4.0 through C4.2 do not correspond with the setbacks that apply to the R-15 Zoning District. For example, there is a "20' setback" line shown around the eastern, southern, and western project boundaries. However, there is no minimum or maximum setback of 20' for infill developments in the R-15 Zoning District, per Section 4.19. 16. [32.5.2 (b)] Please provide a table indicating the quantity of units proposed within each building. The table should include columns indicating how many units measuring less than 500 sq. ft., 1 bedroom, and 2 or more bedrooms are proposed within each building. a. The total unit count by bedrooms should be specified so that staff can verify that adequate parking spaces are provided in accordance with the multifamily dwelling units parking requirements specified in Section 4.12.6 of the Zoning Ordinance. 17. [32.5.2 (b)] Please state the gross residential density proposed. 18. 132.5.2 (d)] Please show the locations of all Managed and Preserved steep slopes across all applicable drawings. a. Add a legend to each drawing where these features are visible and label each feature. 19. [32.5.2 (b)] Please indicate whether any loading spaces are proposed within the development. Loading spaces must meet the design standards specified in Section 18-4.12.18 of the Zoning Ordinance. 20. [32.5.2 (b)] In accordance with Section 18-4.12.13 (e), please show the dimensions for the dumpster pad and associated improvements on Sheet C4.2. 21. [4.12.19 and 32.7.9.7 (a)(3)] Please provide a profile view detail with dimensions and materials of the trash compactor enclosure to verify compliance with the screening requirements contained in the Zoning Ordinance. Please note that fences or other constructed screening measures must be a minimum of six feet (6') in height, as specified in 32.7.9.7 (e). 22. [32.5.2 (j)] Please label all existing sewer and drainage easements by type and include a size/width measurement. State the deed book and page for the recorded instrument number in each existing easement label. 23. [32.5.2 (k)] Please label all proposed sewer and drainage easements by type and include a size/width measurement. State the deed book and page for the recorded instrument number in each existing easement label. a. An easement plat application must be submitted, reviewed, approved and recorded prior to final site plan approval for all proposed easements. b. Once the easement plat is recorded, the final site plan must be revised to show the recorded instrument number for the easement plat (deed book and page number). The newly created easements will need to be labeled with the instrument number, easement type, width dimensions, and whether it is public or private. 24. [32.5.2 (n)] ADA compliant striping must be provided across all parking lot drive aisles where handicap accessible parking spaces are provided on opposite sides of the travelway. For example, the handicap spaces in front of the clubhouse should be connected by striping. 25. [32.5.2 (n) and 32.7.2.31 Per Engineering Division comments, a sidewalk and staircase should be installed to provide access to buildings 8 and 9 from the four (4) parking spaces south of the structures. Additionally, a sidewalk and staircase should be installed to provide access from the four (4) parking spaces between buildings 4 and 5 to the recreation area to the south. 26. [32.7.2.31 Add a sidewalk along the south/west side of the travelway between building 7 and building 8. ADA compliant ramps and crosswalks should be installed at the north mouth of the travelway to connect the sidewalks. 27. [32.5.2 (n)] On Sheet C4.1, there is a row of parking on the north side of the travel way between buildings 1 and 2 that states 18 parking spaces are provided. However, there are only 17 spaces in this area. Please revise the label. 28. [32.5.2 (n)] Please clarify what the "3/4 Split" means in each building label on Sheets C4.0-C4.2. 29. [32.5.2 (r)] Provide a Legend on each drawing showing all symbols and abbreviations visible. 30. [32.5.2 (n)] Please state the height of all proposed fences and retaining walls in the labels used on the drawings. Profile view details of all proposed fences, retaining walls, and constructed screening measures will be required with the final site plan. Each will need to show the types of materials used and dimensions. a. See Engineering Division and Inspections Division comments for additional details on retaining wall requirements. 31. [4.7 (d)] All proposed open space areas that will be privately owned shall be subject to a legal instrument ensuring the maintenance and preservation of the open space that is approved by the agent and the county attorney in conjunction with the approval of the subdivision plat or site plan. a. Prior to final site plan approval, an easement or maintenance agreement must be resubmitted, reviewed, and approved by the County that demonstrates that private open space areas (including the tree save areas that will be used to earn the density bonus, and recreational open space areas) meet this requirement for maintenance and preservation. 32. [32.5.2 (e)] Please provide more details about the existing landscape features as described in Section 18- 32.7.9.4(c). a. The Albemarle County Conservation Plan Checklist and Chapter 3.38 of the Virginia Erosion and Sediment Control handbook. The Conservation Plan Checklist will need to be signed by the owners and provided as an exhibit on major amendment prior to approval. This is required to verify that the proposed 10% density bonus for maintenance of existing vegetation is possible. See Section 18.4.1 for additional details. b. [32.7.9.4 (c)] In both tree save areas, please identify the locations of all existing vegetation types that will be preserved. Use callout to identify the species of each vegetation type. Add a table to the Landscape Plans that identify the quantities, caliper, and height of all vegetation within these areas that will be saved to earn the density bonus. c. The grading drawings and landscape plans should show the tree and vegetation protection measures that will be installed to protect existing vegetation from disturbance. The limits of disturbance should be labeled on both drawings and symbology should be added for the fences or other protection measures that will be installed. 33. [32.7.9.61 The landscape plans do not include a calculation for the minimum 5% landscaping required within the parking area. Based on the 1.66 acres of parking area on site, a minimum of 3,616 sq. ft. of canopy coverage is required within the parking area. Please add this calculation to Sheets L1.0-L2.0 and provide a table identifying the trees and shrubs proposed that will meet this requirement. a. [32.7.9.6 (c)] Provide a table stating the species, quantity, size at time of installation (caliper and height) of all proposed vegetation that will be used to meet the 5% interior landscaping canopy requirement. All vegetation proposed to be installed should be from species listed on the Albemarle County Recommended Plants List. b. The table should state the canopy coverage per single item in each individual vegetation type, and a column stating the total canopy coverage based on the overall quantity of each vegetation type. Please consult the Plant Canopy Calculations table for this information. 34. [32.7.9.71 The "Parking Screening Requirements" table on Sheet L1.0 indicates that no parking screening is being provided. However, the parking spaces on the north and south sides of the development must be screened in accordance with the Ordinance because properties to the north/south are zoned residential and rural areas. The landscape plans will need to be revised so that screening is provided. a. [32.7.9.7 (c)] Add a table to the landscape plans stating the species, quantity, size at time of installation (caliper and height) of all proposed vegetation that will be used to meet the parking lot screening requirement. All vegetation proposed to be installed should be from species listed on the Albemarle County Recommended Plants List. i. Evergreen trees shall be a minimum four (4) feet in height when planted. Shrubs shall be a minimum eighteen (18) inches in height when planted. All trees to be planted shall meet the specifications of the American Association of Nurserymen. b. The table should state the canopy coverage per single item in each individual vegetation type, and a column stating the total canopy coverage based on the overall quantity of each vegetation type. Please consult the Plant Canopy Calculations table for this information. c. [32.7.9.7 (d)] On the south side, a planting strip measuring a minimum of 20' in depth must be provided between the parking areas and development boundary. This should be shown and labeled on Sheet L1.0. 35. [32.7.9.81 The "Tree Canopy Calculations" table on Sheet L1.0 is incorrect, a minimum of 20% overall canopy must be provided, not 10%. Please revise. a. An overall canopy calculation table should be provided stating the total amount of vegetation that will be installed and preserved to meet this requirement. This includes all new materials being installed in accordance with Sections 32.7.9.5, 32.7.9.6, and 32.7.9.7. 36. [32.7.9.91 Please add a note to the Landscape plans stating "All landscaping shall be installed by the first planting season following the issuance of the first certificate of occupancy within the development." 37. [32.7.9.91 Please add a note to the Landscape plans stating "All landscaping and screening shall be maintained in a healthy condition by the current owner or a property owners' association, and replaced when necessary. Replacement material shall comply with the final site plan approved landscape plan." 38. [32.7.8 and 4.17] The initial site plan does not include a lighting plan in accordance with the requirements of Section 4.17 of the Zoning Ordinance. Please include a lighting plan on the next submittal and address the following: a. [4.17.4] Please provide a luminaire schedule stating the quantity of each outdoor luminaire proposed, the model number, the fixture type, wattage emission, etc. b. [4.17.4 (a)] Please provide documentation from the manufacturer that all proposed outdoor luminaries exceeding 3,000 lumens are full -cutoff fixtures. c. Please state the pole height of all outdoor luminaires. d. [4.17.4 (b)] Please show foot-candle measurements within the development and along all existing and proposed street right of ways and property boundaries. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half ('/2) foot candle. e. Please add a note to the lighting plan which states "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half footcandle." 39. [32.6.2 (d) and Chapter 14] Please submit an easement plat and application to the County that shows all new easements proposed by the site plan. This includes all new drainage, stormwater, public access easements, etc. The easement plat must be reviewed, approved, and recorded prior to approval of the final site plan. 40. [General Comment] Prior to final site plan approval, a WPO plan must be submitted, reviewed, and approved by the Engineering Division. Please see Engineering comments below for additional information. 41. [General Comment] Please provide more information on how the proposed affordable housing units will comply with the requirements outlined in Section 18.4.3 of the Zoning Ordinance. The Chief of Housing will need to verify that the plans comply with the requirements prior to final site plan approval. See additional Code sections below: a. [18.4.3 (b)] The initial sale price for sale units or the rental rate for a period of at least ten (10) years for rental units shall qualify as affordable housing under either the Virginia Housing Development Authority, Farmers Home Administration or Housing and Urban Development housing choice voucher program. b. [18.4.3 (c)] If rental units, the developer shall enter into an agreement with the County of Albemarle restricting the rental rates of the affordable units for a period of at least ten (10) years or until the units are sold as affordable units, whichever comes first. c. [18.4.3 (i)] The occupancy of the affordable units shall be restricted to those households with incomes at or below eighty (80) percent of the area median income for for -sale units and at or below sixty (60) percent of the area median income for rental units. The chief of housing or his designee must approve all purchasers of for -sale units based on household income. Prior to issuance of the first certificate of occupancy for a building providing affordable rental units, the developer shall enter into a rental rate agreement with the county, approved by the county attorney, that delineates the terms and conditions pertaining to rental rates, occupancy and reporting during the minimum ten (10) year period. Please contact Cameron Langille at the Department of Community Development at blan ig lle(c�r�,albemarle.org or 296- 5832 ext. 3432 for further information. Comments From Other Reviewers: Albemarle County Engineering Services (Engineer) — John Anderson, janderson2galbemarle.org — Requested Changes, see attached. Albemarle County Information Services (E911) — Andrew Walker, awalker(kalbemarle.org — See Attached Recommendation. Albemarle County Building Inspections — Michael Dellinger, mdellinger(c-r�,albemarle.org — Requested Changes, see attached. Albemarle County Department of Fire Rescue Shawn Maddox, smaddox(c-r�,albemarle.org — Requested changes, see attached. Albemarle County Service Authority — Richard Nelson, rnelsonnserviceauthorit,�org — Requested changes, see attached. Rivanna Water and Sewer Authority — Victoria Fort, vfort&rivanna.org, 434-977-2970, ext. 205 — See ACSA comments. Virginia Department of Transportation — Willis Bedsaul, willis.bedsaulkvdot.virginia.gov — No Objection, see attached. COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 Site Plan Review Project title: Berkmar Drive Apartments — Initial Site Plan Project file number: SDP201900001 Plan preparer: Mitch Bowser, P.E., Timmons Group [mitchell.bowser(a)timmons.com] 1001 Boulders Pkwy, Suite 300, Richmond, VA 223225 Owner or rep.: Uptown Village LLC / P.O. Box 5548, Charlottesville, VA 22905 Plan received date: 14 Jan 2019 Date of comments: 14 Feb 2019 Plan Coordinator: Cameron Langille Reviewer: John Anderson SDP201900001— For ISP approval (Engineering defers to Planning): 1. Boundaries of TMP #32-53 do not match current real estate records. Sheet C2.0 indicates parcel boundary to be abandoned by separate instrument, but this poses several issues: a. If ISP were approved and boundary is not abandoned with new boundaries created to match ISP, there are design implications, beginning with site plan approval for an unrecorded parcel. b. Similar to a., Sheet 0.0 bonus density relies on boundary adjustment that creates a parcel of 17.40 Ac., which does not exist at present. Engineering recommends against bonus density that reflects 17.40 Ac. unless recorded boundaries match overall acreage shown on C0.0 and C2.0. 2. Recommend include reference to SDP201900001 in plan title, if ISP resubmittal is required. 3. Provide inlet /storm pipes to capture and convey right turn lane storm runoff from Berkmar Drive. Ref. Inset I-2, sheet C6.2. Show with ISP for recommendation of ISP approval. Note: detention may be required. 4. Engineering cannot check stormwater quality and quantity values intended to show on -site SWM facilities and offsite nutrient credit purchase ensure compliance with VSMP requirements, since calculations are not provided. Energy balance equation is required at each discharge point, since release is to multiple natural undefined channels. Provide preliminary design data to support quality /quantity values shown on C6.0 (including VaRRM .xls), or disclaimer Note that reads: "SWM values presented with initial site plan are estimates. Albemarle County has not reviewed or approved estimates." 5. C6.0: DEQ-approved hydrodynamic separators: StormTrap® and SciClone® systems require frequent first - year inspection, with periodic inspection, thereafter, but inspection requires safe access. Berkmar HOA must contract for vendor maintenance and inspection services, which will be impeded if traffic is a threat, or if parked cars prevent access. Any access to hydrodynamic separators must be located outside internal travelways and parking drive aisles. If located in a parking space, that space is forfeit and must be striped and signed `No parking' to ensure access is possible. Alternatively, locate hydrodynamic separator manways outside paved surfaces, > 4-ft. beyond nearest curbing. Reference docs: https://www.swbmp.vwrravt.edu/wp-content/uploads/HD_Application_SiteSaver_Item-9.pdf (StormTrap), and https://www.swbmp.vwrrc.vt.edu/wp-content/uploads/fID_Application_ SciClone_ Item-Kpdf (SciClone). For Final Site Plan (FSP) qpproval: C2.0 Engineering Review Comments Page 2 of 4 6. Investigate Ex. SWM basin shown near north boundary of Parcel C. SWM facilities are rarely eliminated without design of a replacement system. Provide VSMP/WPO plan that considers impact to any existing SWM facilities. Address loss of stormwater quantity or quality control due to final site plan design, if any. 7. Investigate suspected cemetery at southwest corner of Parcel C. Take necessary precautions and measures required by law to not disturb and to preserve human remains, or burial caskets. Avoid impacts via design. Properly identify, address, and mitigate any permissible encroachment upon suspected burial grounds. 8. Obtain all necessary VDOT permits to work within public right-of-way, Berkmar Drive, SR 1403. 9. Obtain and furnish copy of wetland delineation coordination with the U.S. Army Corps of Engineers. Provide copy or evidence of permit coordination with the USACE for impacts to waters of the U.S., or wetlands, consistent with federal and state law. 10. Proposed boundaries should be labeled as such, distinct from existing property boundaries. Boundaries shown as existing must match recorded land records /plats. Ref. County GIS. 11. Clarify and include with FSP text of Note #8 and Exception #10 shown with cemetery label. 12. Design may not rely on County GIS, or LiDAR data. Design must be based on field survey data points obtained within the past 12-months, or visually field -verified by the designer within the last year. Ref. existing conditions plan view information, item #2, Final Site Plan checklist (attached). 13. C4.0: 3.5 Ac. tree save area is unrealistic. At no point does `tree save area' lie > 10' from retaining walls. At certain points, nearest approach is 3' or 4'. Engineering advises Planning against accepting 3.50 Ac. `tree save area' as realistic estimate of area of trees that will survive construction of high retaining walls. Also `tree save area' must exclude ACSA water/sanitary sewer corridor near NE edge of development. Trees will be cleared from this utility easement. Engineering recommends a 20' minimum offset for any `tree save area' adjacent to any retaining wall. C4.0: 14. Ensure parking /sidewalk design conforms to a permissible zoning ordinance option (Ref. pg. 17, ACDSM; image below). Bumper blocks are required for all parking spaces 18' in length adjacent to 5' w sidewalks. 6. Parking dimensions; the following graphics is helpful in understanding the zoning ordinance parking dimensions; 6"(in b pl.mhur +rup 1S' packing spates 6' sidewalk - Is' parkala ipaC es 2.- face __ 1 tnunper block q• side-alk 15. Provide retaining wall design for all retaining walls. Ref. Final site plan checklist. Engineering Review Comments Page 3 of 4 16. Provide handrail for all retaining walls > 4-ft. high. Provide detail (VDOT HR-1). C4.1 17. Engineering recommends walk and stairs from 4 parking spaces between buildings 8 and 9 to provide access (down) to apparent front entrance of these buildings. Similarly, recommend walk and stairs from 4 parking spaces between buildings 4 and 5 to provide access (up) to the recreational area in front of these buildings. 18. Engineering recommends sidewalk adjacent to 4-space parking areas between buildings 8 and 9, and between building 8 and the travelway that connects outer and inner loop parking aisles. 19. Stop signs must be shown located prior to CG-12 ramps and pedestrian crosswalks. 20. Revise CG-12 in plan view to match Detectable Warning Surface detail, VDOT sheet 3, plan sheet C4.3, for ramps aligned perpendicular with, not diagonally to, two receiving ramps. Please call if any questions. 21. Ensure internal travelways, parking areas, islands, loading spaces, grades, etc. meet site plan requirements listed at Ch. 18-4. 22. Provide VDOT GR-2 guardrail between 61 parking spaces and proposed retaining wall along north edge of development, beginning northwest of building 3, ending just west of building 6, at bend in retaining wall. C4.2 23. Inset I-2, right turn lane section: Label surface asphalt, base asphalt, and base stone thickness. Provide pavement Design (DI, DP). 24. Design and show storm drain inlet for right turn lane off Berkmar Drive. Show storm pipe. 25. Provide stop or yield traffic sign at internal travelway intersection near north end, bldg. 12. 26. Provide VDOT GR-2 guardrail between 43 parking spaces and proposed retaining wall. 27. Provide complete retaining wall design for Engineering review. Reference retaining wall plan checklist (attached). 28. C4.3: Provide pavement design for heavy duty pavement section (travelways /parking area aisles). Provide ADT at full build -out. (ADT may vary for different loop sections of internal travelways.) 29. C5.0: Engineering recommends against water main /sanitary sewer pipes passing beneath retaining wall; recommends, instead, skirting the wall entirely by routing distribution and collection around the east end of the wall. Engineering recommends steel carrier pipes and concrete lintels for water and sewer distribution or collection mains that may pass beneath (or through) any retaining wall. C6.0: 30. Qio values may be relevant, but Qi-year peak flow is most relevant. Design must meet state stormwater quantity requirements via energy balance equation based on Qi,'ear. 31. Offsite grading easements are required. Submit easement plat application. Provide copy of recorded offsite easement deed/s. 32. Provide complete drainage design. Ref. Albemarle County Drainage Plan checklist (attached). Provide VDOT LD-204, LD-229, LD-268, LD-269 design tables. All appear relevant. Use VDOT table format. 33. Provide contour labels for existing contours, especially south, west, and north of proposed development. 34. Ensure FSP reflects subgrade dimensions of hydrodynamic separators. StormTrap systems are far larger than a std. VDOT MH. Plan view final site plan sheets should reflect true, not approximate or schematic dimensions. 35. ISP proposes large volume subgrade SWM facility detention chambers with isolation chambers. Should any of the three proposed large volume systems fail, there is no backup, or bypass. Engineering requests Applicant submit long-term performance reliability data for proposed 30,OOOcf and 33,OOOcf systems. The largest integrated underground detention systems approved in Albemarle County are for non-residential sites better -positioned to deal with system replacement expense (Fifth Street Station; Stonefield). 36. Engineering encourages Applicant to split 30,000 and 33,OOOcf systems, to design, instead, independent underground detention chambers that provide equivalent combined storm runoff control. Engineering Review Comments Page 4 of 4 37. Revise 33,000cf detention system discharge pipe location. Proposed location through retaining wall is disallowed, per Engineering Division policy. 38. All detention system discharge outfalls must be to a defined channel. Propose grading to define a channel, if none exists. 39. Evaluate new drainage channels for capacity, and erosion. Provide soil stabilization blanket, where needed. 40. Provide high -flow bypass for all hydrodynamic separators and high -flow bypass for all detention systems for events less frequent that the 10-yr, for rainfall intensity > 5.7" in a 24-hr period. Ensure bypass discharge does not cause flooding of travelways. 41. C6.1: Revise matchline sheet 6.1 label to read 6.2. C6.2: 42. For proposed HDPE pipe, ensure pipe is rated adequate for depth of installation. 43. Prepare plat showing SWM facility maintenance and access easements. Show easements. 44. Prepare plat showing private drainage easements for SWM facility discharge pipes. Show easements. 45. Prepare plat showing public drainage easement for site access storm conveyance system elements along Berkmar Drive, or within VDOT right-of-way. Show public drainage easements. 46. Ref. ACDSM image, pg. 15, when designing easement width: EASEMENT WIDTH - DIAMETER + 3' + 3 I H-5' i + 10' 110' MEN,) EASEMENT WIDTH EQLANDLNGL"IP\(E\T I / JYPi DIAMETER I 1' R STOR\(RATER PIPE 47. Sheet scale may be inaccurate; please confirm accurate. 48. L1.0: Use hatching or other symbol to indicate areas of proposed grade steeper than 3:1 and provide note with reference to permanent landscape vegetation hardier than grass. Ref. ACDSM, pg. 22, Sec. 8.A.2. 49. Notes: a. An approved VSMP Plan Amendment is required prior to Final Site Plan approval; please submit WPO Plan at earliest convenience. Coordinate proposed nutrient credit purchase with Ana Kilmer, Albemarle County, once VSMP/WPO Plan is approved. b. Please consider attached Final Site Plan, Drainage, and Retaining Wall plan checklists as aids to design. Checklists guide review. Please feel free to call if any questions. Thank you J. Anderson 434.296-5832 -0069 SDP201900001 Berkmar Drive Apartments ISP 021419 County of Albemarle Department of Community Development ` 401 McIntire Road, North Wing `= Charlottesville, Virginia 22902 PLAN REVIEW COMMENTS - E911 APPLICATION#: SDP2019000001 DATE: 2/ 12/ 19 FROM: Andrew Walker awalker@albemarle.org Geographic Data Services (GDS) www.albemarle.org/gds (434) 296-5832 ext. 3031 This development will require three (3) new road names. See the attached diagram which indicates the segments requiring unique names. These roads will need to be labeled in the next submittal to meet the requirements set forth in the Road Naming and Property Numbering Ordinance and Manual. We strongly recommend providing candidate names to our office for review, in case your first choices are not acceptable. Resources Please consult the County's Road Name Index to check your road names prior to submittal. The Index can be found here: http://www.albemarle.org/albemarle/upload/images/webapps/roads/ A PDF version of the Ordinance and Manual can be found here: httas://www.albemarle.ora/upload/imaaes/Forms Center/Departments/Geoaraphic Data Service s/Forms/Road Namina and ProDerty Numbering Ordinance and Manual.Ddf Parcel and mapping information can be found here: http://gisweb.albemarle.or If you should have any questions, please do not hesitate to contact our office. Review Comments for SDP201900001 11nitial Site Plan Project Name: Berkmar Drive Apartments - Initial Date Completed: Wednesday, January 23, 20 9 DDepartment1DivisionfAgency: Review Sys: Reviewer: Michael Bellinger CBB Inspections Requested Changes Add the following note to the general notes page: Retaining walls greater than 3 feet in height require a separate building permit_ Walls exceeding 4 feet in height require an stamped engineered design also_ Add the following note to the general notes page: Accessible parking spaces and access isles shall not have a surface slope greater than 1:48_ Access isles shall be at the same level as the parking space they serve_ Add the following note to the general notes page: ALL water lines, sewer lines, and fire lines from the main to the structure MUST have a visual inspection performed by the buildng department_ Add the following to the general notes page: All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks_ Page: County of Albemarle Printed On: 02 19120'19 Review Comments for SDP201900001 Initial Site Plan Project Name: Berkmar Drive Apartments - Initial Date Completed: Fnday: February 08: 2019 DepartmentlDivisionlAgency: Review Status: Reviewer: Shawn Maddox Fire Rescue Requested Changes 1 _ A turn around must be provided at the leading arealdumpster of building 7_ This can be a cul-de-sac, hammerhead, a Y or other approved means- _ Please verify the emergency access is a minimum 20' of clear unobstructed travel width- 3- Due to the heights of the buildings the travel way must be increased to 26' for at least one contiguoLis side of each building greater than 30' in height 4_ A knox box will be required on each building_ Please add a note indicating the requirement and that the location can be coordinated with the fire marshal's office- 5- Afire flow test will be required prior to final acceptance_ Page: County of Albemarle Printed On: 02 19120'19 Cameron Langille From: Richard Nelson <rnelson@serviceauthority.org> Sent: Wednesday, January 23, 2019 2:46 PM To: Cameron Langille Subject: SDP201900001 Berkmar Drive Apartments - Initial Cameron, I recommend approval for SDP201900001 Berkmar Drive Apartments — Initial with the following conditions: Submit 3 copies to ACSA for review. RWSA sewer capacity will be required. Downstream sewer upgrade utility plan will need to be approved prior to final approval of site plan. Thanks, Richard Nelson Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (434) 977-4511 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper. Virginia 22701 Stephen C. Brich, P.E. Commissioner January 29, 2019 Cameron Langille County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SDP-2019-00001- Berkmar Drive Apartments — Initial Site PIan Dear Mr. Langille: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Timmons Group, dated December 28, 2018 and offer the following comments. Land Use 1. Please show mill and overlay on plans in accordance with WP-2 and show limits of mill and overlay. Also please add the detail to the plans. 2. Please provide an MOT plan in accordance with the Virginia Work Area Protection Manual. 3. Please provide sight distance lines and profile for proposed entrance onto Route 1403 Berkmar Drive. 4. Please provide drainage calculations for proposed storm water structure tying into the Roadside ditch, pre and post construction for adequacy of discharge. AIso please plot HGL on profile. 5. Please provide a drainage inlet on the northern side of the entrance. 6. Please refer to appendix F, page F-125, of the Road Design Manual for Commercial Entrance Design standards along Highways with Curb and Gutter. Minimum width for commercial entrances needs to be 30'feet or greater. 7. Please provide trip generation data. 8. Please provide CG-12 Ramps at proposed entrance for crossing street. Please note that the final site plan must show conformance with the VDOT Road Design Manual Appendices B (1) and F, as well as any other applicable standards, regulations, or other requirements. If further information is desired, please contact Willis C. Bedsaul at 434-422- 9866. WE KEEP VIRGINIA MOVING January 29, 2019 Mr. Langille Page Two A VDOT Land Use Permit will be required prior to any work within the right of way. The owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, Al Adam J. Moor� e, P.E. Area Land Use Engineer Charlottesville Residency WE KEEP VIRGINIA MOVING