HomeMy WebLinkAboutSDP201800079 Review Comments Major Amendment, Final Site Plan 2019-03-07'AL Eli � rRGS�t� County of Albemarle Department of Community Development Memorandum To: Craig Kotarski From: Megan Nedostup- Principal Planner Division: Planning Services Date: December 3, 2018 Rev1: March 7, 2019 Subject: SDP-2018-079 Keswick Hall Spa- Major Amendment The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approve the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Requirements: 1. An additional $17.38 needs to be paid for the notification. 2. [32.5.2(a)] The allowable maximum height under RA zoning is 35 feet. The proposed building exceeds the height. Revise so that the building height is limited to 35 feet. 3. [4.17] Provide the property lines on the lighting plan for verification of the footcandle requirements. 4. [4.12.13(e)] Any commercial building larger than 4,000 sq ft requires a dumpster pad. Provide a dumpster pad for the spa. e. Each site plats that depicts a commercial or industrial building of four thousand (4,000) gross square feet or more shall provide a dumpster pad that does not impede any required parking or loading spaces: nor any pedestrian or vehicular circulation aisles_ Rev1: Comment not adequately addressed. The dumpster pad is not shown/noted on the plans and must be designed in accordance with the ordinance. 4.12.19 '-%II1NLN- LEI DESIGN REQUI E-sTENTS AND INIPRO EMENTS FOR DUNIPSTER PADS The following design requirements and minimum improvements shall be satisfied for all vehicle access aisles: a_ ilfaterials. Dempster pads shall be concrete. b. Design. The pad shall extend beyond the front of each dumpster so that the front wheels of a track servicing the dempster will rest on the concrete, but in no case shall the length of a concrete pad be less than eight (8) feet beyond the front of the dumpster. The site shall be designed so that stormiA.ater does not run through_ and drains away front areas �vfiere dumpsters are located in order to minimise the potential for contaminating stormwater runoff due to contact with solid wwaste_ Screening_ Dumpsters shall be screened as required by section 32.7.9 and, where applicable, section 30.6_ Please contact Megan Nedostup at the Department of Community Development 296-5832 ext. 3004 for further information.