HomeMy WebLinkAboutSDP201800039 Plan - Approved Initial Site Plan 2018-09-25INITIAL SITE DEVELOPMENT PLAN FOR
FANTOP5, CORNER
I'll -11 giniii
Ulm
KIVANNA DISTRICT, ALE3EMARLE COUNTY, VIRGINIA
SHEET INDEX
C I - COVER 5H FET
C2 - EXISTING CONDITIONS * DEMO PLAN
C3 - SITE PLAN
C4 - UTILITY * GRACING PLAN
C5 - LANDSCAPE PILAN
C6 - ROAD DETAILS * SITE DETAILS
F M I J J :I .111111111IN 4 1-1 J :101 a J -
Tax Map 78 Parcel 58G1 was rezoned to Highway Commercial per ZMA 2013-00002.
The approved proffer statement is as follows:
1. Interconnectivity. Contemporaneously with, and as partt of, frontage improvements along Stony
Point Road (Rt. 20) required in connection with any subdiivision plat or site plan for the Property, the
Owner shall construct a private road from Stony Point Reuel (Rt. 20) across the Property to and
across TIVIP 78-5A to U.S. Route 250, as labeled Road "A" on Exhibit C -l. The location, aligiunent
and design of Road "A" may be adjiusted with approval o;f the County Engineer. The Owner shall
record an easement for the private road granting right of 1public passage over Road "A" which shall
be recorded prior to the request for the first Certificate of'Occupancy for the Property. An access
easement to 1Aa1P 78- 6 shall be provided subject to an agreement between the respective owners to
share the cost of maintenance and construction for sharedi portions of Road "A",
2. No Certificate of Occupancy until Road "A" is camphete. The Owner shall not request a
Certificate of Occupancy for any building on the Propert3y until the private road connection between
U.S. Route 250 and Route 20 is completed along with entrance improvements as required by the
Virginia Department of Transportation. Construction of Road "A" shall be deemed complete when
the County Engineer determines the roadway is safe and convenient for traffic. The location of the
private road connections may vary in accordance with entrance guidelines provided by the Virginia
Department of Transportation.
3. Route 20 Widening. The Owner shall not request a Certificate of Occupancy for any building on
the Property until the Owner has constructed a second north bound lane on Route 20 along the
frontage of the Property such that two full north bound laines are provided on Route 20 from its
intersection with U.S. Route 250 to the intersection of Ro>ad "A" and Route 20.
VICINITY MAP SCALE: 7"=1,000'
LEGEND
DESCRIPTION
EXIST
„a.
EXIST
NEW
DESCRIPTION
EXIST
NEW
DESCRIPTION
..iv
x 125 TC
TOP OF CURB ELEVATION"'"
`'i
�__, __
T
DRAIN INLET (DI)
IV,
x 125
SPOT ELEVATION
-- <ll; --
® 0
STORM/SANITARY MANHOLE
�,IMll
DS
140
c00 —
INDEX CONTOUR
,
1 STS'' .z W
x 12 TW
TOP OF WALL ELEVATION
PLUG
l?hw
x 125 BW
BOTTOM OF WALL ELEVATION
'
OW
WATER VALVE &BOX
BENCHMARK
'
4-
FIRE HYDRANT
vR
STORM SEWER
®
WATER METER
W ,....m.u._.,
RD
ROOF DRAIN
�
�--�
LIGHT POLE
wwom—A;.,
-----
SEWER LINE
m u
- -
UTILITY POLE
VW
WATER LINE
„n.,._.._ „;�,_...._....
SAS
GAS LINE
SANITARY EASEMENT
u a
— OHE
OVERHEAD ELECTRIC WIRE
--
--
GRADING EASEMENT
__----
— USE
UNDERGROUND ELECTRIC
" a v r� , •
DRAINAGE EASEMENT
oHT
OVERHEAD TELEPHONE LINE
..
UTILITY EASEMENT
mMA ri" -r, h =ry
— ucr
UNDERGROUND TELEPHONE LINE
y" _ y
_.
WATER EASEMENT
ACCESS EASEMENT
PROPERTY LINE
STORM DRAINAGE EASEMENT
— - - —
ADJACENT PROPERTY LINE
. wµ ..,,n.
-
VACATED PROPERTY LINE
BUILDING SETBACK
PARKING SETBACK
VICINITY MAP SCALE: 7"=1,000'
iiviAUt HNUVIut=u BY UUUUut` MHN
EXIST
NEW
DESCRIPTION
EXIST
„a.
• • -, ...
TREE LINE
�a
in out
w v.r
FENCE
RIPRAP
66
4<
STREAM
Reta i 1
851 4,350 SF 34 34
GRASS
27 26
53.5
-- <ll; --
—112—
INTERVAL CONTOUR
�,IMll
DS
140
c00 —
INDEX CONTOUR
,
w? 6
ITE
a
4 Y 6
P1`yi
dt
I
L)
zT
1r1 Pyr,%.'`
f `
e CkL y r 4
Iry"'
ar
iiviAUt HNUVIut=u BY UUUUut` MHN
EXIST
NEW
DESCRIPTION
EXIST
„a.
• • -, ...
TREE LINE
�a
in out
w v.r
FENCE
RIPRAP
66
4<
STREAM
Reta i 1
851 4,350 SF 34 34
GRASS
27 26
53.5
-- <ll; --
—112—
INTERVAL CONTOUR
�,IMll
DS
140
c00 —
INDEX CONTOUR
,
C,G-2 GtG-2 STANDARD 6" CURB
Jlq CCG -6 COMBINATION fi" CURB &
GUTTER
NEW DESCRIPTION
1a
8 d
CONCRETE PAVEMENT f
CROSSWALK
SIDEWALK
n
CG -12
in out
w v.r
Hotel
RIPRAP
66
4<
ASPHALT
Reta i 1
851 4,350 SF 34 34
GRASS
27 26
53.5
EC -2 MATTING
1 70 64
135
EC -3 MATTING
140
WETLAND
NEW DESCRIPTION
1a
PARKING COUNT
CROSSWALK
HANDICAP ACCESSIBLE AISLE
/F -N
CG -12
in out
HANDICAP PARKING
NOTE:
1. THE SIZE OF THE SYMBOLS MAY VARY FROM WHAT IS SHOIWN.
PARKING
Required parking:
Hotel: 1 space per room. 122 rooms = 122 spaces
Retail: 1 space per 100 SF. 4,350 SF / 100 = 43.5
80% of 'retail sales area' = 34.8 spaces
Provided parking:
Hotel: 122 spaces
Retail: 55 spaces
Submittal Type
Reviewed and Approved by the
c(gunity ►Development Departme
Dat
e-�4��?�-?�'I�
Pit '.Oki 03 3-' --
Signature
OWNER I DEVELOPER
Pontops Corner, LC.
1100 Harris Street
Charlottesville, VA 22903
ZONING
TMP 78-5A, 5B
HC -Highway Commercial, EC -Entrance Corridor
TMP 78-58G1
HC -Highway Commercial, EC -Entrance Corridor
Per Approved Application Plan. ZMA 2013-00002.
SOURCE OF TITLE
Tax Map 78, Parcel 5A, 5B & 58G1: DB 4358 PG 684
MAGISTERIAL DISTRICT
Rivanna
BENCHMARK
Datum for topography is NAVD88.
SOURCE OF BOUNDARY & TOPO
Boundary & topographic survey information provided by:
Feld survey provided by Roger W. Ray & Associates, Inc. on March 23, 2018.
Datum for topography NAVD88.
BUDDING HEIGHT
Maximum: 65'
SETBACKS
Front minimum = 10 FT from right-of-way. Front maximum = 30 FT from nght-of-way.
Side/Rear lots zoned Highway Commercial, primary structures will be constructed and separated in
accordance with the current edition of the Building Code. No Side Rear max setback.
Hotel complies with stepback front requirement. For each story that begins above 40 FT in height
or for each story above the third story, whichever is less, the minimum stepback shall be 15 FT.
EXISTING USE
Vacant lot
STEEP SLOPES
Managed and Preserved Slopes are shown on C3
PROPOSED USE
New 14,684 SF Hotel, 4,350 SF Retail Building, and Proffered Access Road
LAND USE SCHEDULE
EXISTING Area %
Ex. Buildings 0 SF 1.8
Ex. Pavement 0 SF 3.2
Open space 274,864 SF 95.0%
Total= 274,864 SF (6.31 ac.)
PROPOSED Area %
New Buildings 20,724 SF 7.5%
New Pavement 102,073 SF 37.1%
New Sidewalk 13,812 SF 5.0%
Open space 138,306 SF 50.4%
Total= 274,864 SF (6.31 ac.)
Total Impervious Area = 136,103 SF (49.5%)
WATERSHEDS
This site lies within the Upper Rivanna River Watershed.
This site is not within a watershed of a public water supply.
FLOOD ZONE
According to the FEMA Flood Insurance Rate Map, effective date February 4, 2005 (Community
Panel 51003CO287D), portions of this property lie within a Zone AE 100 -year flood plain.
TRIP GENERATION
Trip generation reflects AM and PM peak hour traffic.
j�,LTH -
u JUSTI INIP �
.45183
o
AM
PM
Use Description
ITE Qty in out
Total
in out
Total
Hotel
310 122 rooms 36 30
66
44 32
76
Reta i 1
851 4,350 SF 34 34
69
27 26
53.5
Total
1 70 64
135
1 71 58
140
Trip generation reflects AM and PM peak hour traffic.
j�,LTH -
u JUSTI INIP �
.45183
o