HomeMy WebLinkAboutSUB201900020 Review Comments Final Plat 2019-03-14�OV AL
� � IRcir�ia
County of Albemarle
Department of Community Development
Memorandum
To: Steve Garrett (Commonwealth Land Surveying, LLC)
From: Paty Saternye- Senior Planner
Division: Planning Services
Date: March 14, 2019
Subject: SUB-2019-20 Robinson Subdivision Subdivision Plat
The County of Albemarle Planning Division will grant or recommend approval of the Final Plat
referenced above once the following comments have been addressed: [Each comment is
preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless
otherwise specified.]
1. [14-302 (A)(3)] Existing or platted streets. Revise the label for Route 250 on sheet 2 to
also include the name of the road.
[14-302 (A)(10)] Right of further division of proposed lots. Revise the development rights
note for the residue to state that it retains only 1 development right and may not be
further divided. Attached please find a Letter of Determination (LOD2007-9) that contains
the history of division since 1980 and specifies how many development rights were
retained by the other parcels that originally formed TMP57-40. Also attached please find
a previously approved and recorded plat (DB 1591 PG 577) that states that TMP 57-40A
contained only 2 development rights after having another parcel (parcel B) added to it.
[14-302 (A)(4), (6) & 14-303 (E)] Private Easements; Alleys and shared driveways;
Dimension standards and information on all lots, streets, alleys, easements, and shared
driveways; Existing or platted streets. Address the following:
a) If any existing private easement exist on the parcel shown them, specify the owner of
the easement and include the deed book and page number for the easement.
b) A deed for the proposed shared driveway easement is required. This deed must be
reviewed and approved by the County prior to plat approval. Please submit a draft
version of the deed for review with the next submission. It is required that the deed is
recorded with the plat.
c) It is suggested, but not required, that shared driveway maintenance agreement be
recorded with the plat. Since it is not required it will not be reviewed by the County.
d) Revise the plat to include a note that specifies that maintenance shall be by the
owners of the lots affected by the shared driveway easement, not by the Virginia
Department of Transportation or the county.
4. [14-302 (A)(9)] Building Sites on proposed lots. Revise the plat to include the
required 30,000 square foot building site rectangle for Lot 1. Ensure that all
requirements of 4.2.1 & 4.2.2 are met and that the rectangle is the full 30,000 square
feet specified. What is currently shown on the plat appears to be only 14,400 square
feet in size. Also, please note that no critical slopes or water protection ordinance
areas can be included in the "Building Site", but the proposed drainfields can be
within the area.
5. [14-302 (A)(11)] Instrument creating property proposed for subdivision. Revise the plat to
include the deed book and page number of the instrument that created the property.
[14-302 (A)(5) & 14-303 (L)] Public easements; Public utility, drainage and sight distance
easements. Specify the owner, deed book and page number, and width of all the public
easements crossing or within either of the subject parcels. An electric line appears to be
crossing the property, but the required information for the easement has not been
included in the plat. If the width of the easement is definite, it should also be shown
graphically. Also, show the location and dimensions of any other public utility, drainage
and/or sight distance easement on the plat.
7. [14-309; 14-310] Soils evaluation; Health Director Approval. The soils and drainfields
submission have been forwarded to the Health Department. VHD approval is required
prior to approval of this subdivision plat.
8. [14-302 (13)(7)] Reservoir watershed; agricultural -forestal district. See Engineering
comments about revision of the watershed note.
9. [14-302 (B)(8)] Yards. Revise the plat to include the setback requirements for the RA
zone. Although the setbacks appear to be shown graphically no labels are provided.
10. [14-302 (B)(9)] Flood Plain. Revise the plat to address the following:
a) Revise the flood plain note to be correct as follows:
i. The flood plain note is for the existing parcel, and not just the proposed parcel.
There are both X and AE areas on the parcel.
ii. Provide the date of the FEMA panel referenced.
b) Revise the linework for the flood plain so that it matches that shown on the County's
GIS system. Although the shape of the line appears to be correct, it appears to be
shifted horizontally and vertically, not showing the 100-year flood plain in the area of
the parcel in which it exists.
11. [14-302 (B)(10)] Stream Buffers. See comments from engineering on the stream
buffers. Provide the exact wording of the stream buffer note, specified in the
checklist, as a note on the coversheet of the plat.
12. [14-303 (E)] Dimension standards and information on all lots, streets, alleys, easements,
and shared driveways. Revise the label for the new access easement to instead be
"New 20' Shared Driveway Easement"
13. [14-303 (F)] Identification of sections, blocks and lots. Revise the label for the
residue of TMP 57-40A to include "residue".
14. [14-303 (H) & 14-421] Monuments. Address the following:
a) Revise the Iron Found and Iron Set to be correct on the plat. There is a pin in the
middle of the proposed boundary line that is labeled as "found". It appears this
should be a "set" pin.
b) Provide Iron Found labels on all existing lot corners that have iron pins already
placed.
c) Include in the legend on sheet two what "MON." stands for.
15. [14-303 (1)] Bearing and distance ties. Revise the plat to include the required ties (at
least two) to the location of the shared driveway easement.
16. [14-308.1] Groundwater assessment information. The groundwater assessment has
been attached.
17. [14-316] Approval of entrance onto public street. VDOT approval of the entrance is
required prior to subdivision plat approval. The plat has been distributed to VDOT, but
their comment or approval is still pending.
18. [Comment] Either include in the plat, or on a separate exhibit, the critical slopes as they
are shown on the County's GIS. If it is provided on a separate exhibit that exhibit must
also show the Water Protection Ordinance (WPO) and flood plain overlays and the
proposed "Building Site". This information is required to ensure that there is sufficient
area on the parcel that does not contain the restricted areas and will meet the building
site requirement for size and shape.
19. [Comment] The planning reviewer has discussed engineering's comment #11 and it has
been decided that the scale of the plat is sufficient and does not need to be revised.
20. [14-302 (13)(1)] General Information. When revising the plat include a date of last revision
on the plat. This date should be updated prior to each resubmission.
21. [Comment] See the attached comments from engineering. VDOT and VDH comments
are still pending and will be forwarded to you when they become available. Approval of
all of the reviewers is required before approval of the plat.
Please contact Paty Saternye at the Department of Community Development 296-5832 ext. 3250
for further information.
CC: T.E. Robinson (Owner)
Review Comments for SUB201900020 Final Plat 1-1
Project Name: ROBINSON DIVISION - FINAL
Date Completed: Saturday, March 09, 2019 Department/DivisiordAgency: Review Status:
Reviewer: John Anderson - CDD Enaineerina - Requested Changes El
Sheet 2
1. Provide deed bk.-pg. reference to instrument creating TMP 57-40A.
2. Label TMP 5740A residue.
3. Near entrance to residue, there are 3 segments and 4 distances: 149.60, 20.92, 35.71,
clarity. If one of these distances is a tie, provide `tie' notation.
4. New acreage in bold text is difficult to read (blurry)_ Ensure print is legible.
5. Boundary creating Lot 1: 54.15' and 20.51' are included in 409.07' distance. Provide notations indicating this is the
If one (or more) distance is a tie, provide `tie' notation.
Label overhead power line deed bk.-pg. reference to easement.
Associate text label reading `0.5 Miles to S-R. 240' with a point on the property boundary.
case.
7.
115.10 (ft_)_ Revise for
8. Sheet 1: FEMA note is inaccurate. Property lies in FEMA flood zone °AE'. Revise note for accuracy.
9. If lot is not to be served by public water and/or sewer, please see requirements at 14-308.1 (groundwater
assessment information) and 14-309 (soil evaluations).
10_ Note, sheet 1: `The property shown herein is in a water supply watershed.' Please identify which watershed.
11. [14-301.B.] Revise scale to one (1) inch equals fifty (50) feet.
12_ [14-302_B.10.1 Provide required stream buffer note exactly as shown in ref_ ordinance.
13_ [14-303_H.] Provide the location and material of all permanent reference monuments.
14. [14-303.1.] Provide a definite bearing and distance tie between not less than two (2) permanent monuments on the
exterior boundary of the property.
15. [14-304] Include note that critical slopes exist on property (Lot 1 and residue). Recommend show critical slopes,
graphically_
Page: 1 County of Albemarle Printed ❑n: 03/14/2019