ARB2019-26: Goodwill sign
HNM 3/15/19
SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business
REF
CHECKLIST ITEM
NOTES
TYPE
9.b
For internally illuminated signs, channel lettering (mounted on a
OK: front -lit channel letter signs (2) proposed on
raceway or individual letters) is preferred to cabinet signs.
raceways.
5.b
When channel letters cannot be adequately accommodated, internally
OK: one cabinet sign (logo) proposed
illuminated cabinet signs may be considered.
6
Reader boards are discouraged.
N/A: no reader boards proposed
MATERIALS
4.c
Materials used in the sign should complement the building being
OK: the materials are aluminum and acrylic;
served by the sign.
while these do not complement the building
materials, they are standard sign materials
commonly approved.
COLOR
4.e
Color for raceway -mounted channel letters, the raceway shall match
OK: note states "raceway painted to match
the wall color.
building color."
Sign colors must be harmonious with each other.
OK: One predominate color is Blue (PMS 286);
Sign colors must not clash with the site, when viewed in daylight and
accent colors are black and white (the black is
at night.
opaque). The proposed blue is a mid-range and
not overly intense. The channel letters use one
Overly intense color, (such as dayglo or fluorescent colors), are
prohibited.
color while the logo uses three.
Use of three colors or less (black and white considered as colors).
Additional colors may be approved if they contribute to the sign
balance/unity.
SIZE, SCALE, PROPORTION, AND LOCATION
4.b
Signs may not exceed the size, height and setback requirements as
OK: channel letter 1 = 130.333 sf, channel letter
outlined in Section 4.15 of the Albemarle County Zoning Ordinance
2 = 32.5 sf; logo = 18.25 sf on building frontage
unless sign has a variance).
= 267'-8"
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall area is a good
OK: channel letter 1 = 4' x 32'-7"; channel letter
A.A
working proportioning system for placing a sign.
2 = 1.5' (x 2 with 9" space in between lines = Y-
9" total height) x 8'-8"; logo = 4'-9" x 3'-10"
ARB2019-26: Goodwill sign
HNM 3/15/19
REF
CHECKLIST ITEM
NOTES
Appendix
Color, form, surface pattern, shape, and disposition of elements and
OK
A.A.4
openings in an architectural design can affect our perception of scale
and can im act the appearance of a sign on a building.
9.d
The wall sign's size must coordinate with the architectural element's
OK: channel letter 1 is centered horizontally and
size.
vertically in the portico's equivalent to a frieze;
it is an appropriate size for the location. Channel
The sign should not over -crowd the architectural element, the wall, or
the sign area.
letter 2 is centered in the sign band; the size of
the sign band is not provided, but the illustrationshows
Buildings and building elements should not be used as billboards.
the sign has an appropriate scale. The
logo is placed at the apex of the pediment. None
are of a scale that overcrowds the architectural
9.a
Wall signs must integrate with the building's architecture.
element on which is placed, nor are architectural
The sign placement should not obscure architectural features or
details, (such as cornices, windows, columns, pilasters and paneling).
features or details obscured by the proposed sign
placements.
9.d
An appropriate height for channel letters in a 30" high sign band is
The size of the sign band in which channel letter
18".
2 is proposed has not been provided; therefore, it
is indeterminable if a 3'-9" sign height will have
This allows 6" of unoccupied space above and below the letters.
a minimum of 4" clearance from top of sign
band to top of sign and from bottom of sign band
4" of clear space above, below, and to the sides of a channel letter sign
is considered a minimum, with larger clearances required for larger
to bottom of sign. This must be made a condition
sign bands.
of approval.
Degree of visibility, the distance from the Entrance Corridor, and the
OK: the size of the channel letter signs and logo
architectural design of the building/area will determine sign size,
are appropriate in re: the scale of the building
lacement, and proportions.
and its distance from the EC.
4.d
Lettering should be in proportion (font size and typeface style) to the
OK
sign and the building.
Use of three typefaces or less.
OK: 3 typefaces proposed
Additional typefaces may be approved if they contribute to a
N/A
balanced/legible/unified sign design.
ARB2019-26: Goodwill sign
HNM 3/15/19
REF
CHECKLIST ITEM
NOTES
9.e.iv
The width of the outline must be in proportion to the width of the
N/A: no outline proposed
letter.
An outline width of 1/8" has been found to be an appropriate sign
dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
4.f
The ARB may require that the color and scale of standard templates
OK
for trademarks, service marks, corporate logos and graphics be
modified.
When used, trademarks, service marks, corporate logos and/or
The graphic/logo is a separate cabinet sign,
graphics should be incorporated as an integral part of the overall sign.
placed above the channel letter sign. It is
replacing a previously -approved logo/graphic in
the same location.
5.a
External or no illumination is preferred for approved graphics/logos;
The cabinet logo has internal illumination, which
is not approved in the CSP for this shopping
5.b
internal illumination may be considered for approval on a case-by-case
basis.
center.
LIGHTING
9.e.i
External (or no) illumination is preferred for wall signs.
The channel letters are internally illuminated
with LED lights
5.f
Any internal illumination is considered to contribute to visual clutter
OK
and will be limited.
5.c
Internal illumination design approval will be evaluated on size,
OK
balance, complexity, and distance from the Entrance Corridor.
9.e.iv
The backgrounds of such cabinet signs must be made opaque (zero
OK: cabinet is aluminum back, 5" aluminum
light transmission).
return, and 1" Wagner Jewelite trim cap "to
prevent light leaks"
5.e
External illumination should be shielded and not create glare.
N/A: no external illumination proposed
All external light sources shall be white.
9.ii
Sign lighting (external) should be shielded so that it illuminates only
face of the sign and does not shine beyond the edge of the sign.
ARB2019-26: Goodwill sign
HNM 3/15/19
REF
CHECKLIST ITEM
NOTES
9dii
Channel letters with translucent faces must have no light spilling
OK: letters are aluminum back, 5" aluminum
outward from the top, bottom, sides or back.
return, and 1" Wagner Jewelite trim cap "to
prevent light leaks"
Faces and returns of channel letters shall be opaque when back -lit
N/A: no back -lighting proposed
(halo -lit).
9.iv
Cabinet signs shall have a non -illuminated background, or an opaque
OK: cabinet sign has an aluminum back
zero light transmission background.
Cabinet signs shall be constructed such that no light spills outward
OK: see 9iii above
from the top, bottom, sides or back.
5.g
All illumination shall be non -blinking.
OK
S.h
An exposed light source that forms the body of a sign, (such as
N/A
exposed neon signs), shall not be used in the Entrance Corridors.
ARB ACTIONS
If LED lighting is proposed the sign drawing must state The level of
OK: note provided on sheets 5 and 7
illumination provided by the LED lights will not exceed the
illumination produced by a single stroke of 30 milliamp (ma) neon.
Action on ARB -P (BP)2001-
Red acrylic #2283 has been determined to be an
N/A: no color red proposed
12 Wood Grill
inappropriate color for signs. Pantone color match
for 2283 is 485C. Red #2793 has been approved as
an acceptable substitute. Pantone color match for
2793 is 187C. See below.
12/21/15 action on ARB
Generally, for signs in the Entrance Corridors, red 485
2015-114 & -115 Shell Signs
may be acceptable on a case-by-case basis as a
secondary color.
ARB Action
Visual clutter resulting from adjacency, for example at the
OK
Memo: 5/7/12
Hardee's locations, is a reasonable basis for not allowing
illumination of the graphic.
ARB Action
Accent color letters can be used in a sign when portrayed as a
N/A: no accent color letters proposed
Memo: 8/3/2015
graphic, up to 33% of the length of the sign.
Completeness Check for Signs
Project #/Name: _ARB2019-26: Goodwill_
Date Received at County: _3/1/19
Date Received in Design Planning: _3/6/19
Date of Checklist Check: 3/15/19
Assigned to/Date:
HNM 3/6/19
FEES 0
3. ARB Review — Will the permanent sign(s) be constructed in an Entrance Corridor?
(See the Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors)
❑ Yes ('Phis sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $129.00
Comprehensive Sign Review. See ARB requirements next pages)
® Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee
Comprehensive Sign Review. See ARB requirements next pages)
❑ No ('This sign will not be constructed in an Entrance Corridor) $ 0.00
FEE TOTAL (Please add all the amounts checked in sections I — 3): $
WALL SIGNS
® A drawing, to scale, showing dimensions of the sign (length, height, depth).
® Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing
® The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also
include these dimensions on the diagrams provided in Appendix B)
® Sign lettering and/or graphics in their proposed location.
® Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color
illustration of the front and side elevations of the sign showing:
o Indication of sign type (channel letters, cabinet, panel, etc.).
o Indicate on the drawings the proposed materials and colors. Include standard color identification numbers
(Panton, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter
signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is
attached.
o Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint
chips that accurately reflect the proposed colors are acceptable.)
o Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style,
shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17.
o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque
materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be
detected nor can objects be seen through it.
ILLUMINATION REQUIREMENTS
® The location of proposed light fixtures identified on a plan and/or elevation
❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must
meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance.
NOTES: Application complete