Loading...
HomeMy WebLinkAboutSDP201800090 Plan - Revision Initial Site Plan 2019-03-04SITE DATA: TAX MAP PARCEL: 061WO-01-OA-00300 PARCEL AREA: 1.42 ACRES LIMITS OF DISTURBANCE: 1.35 ACRES ZONING: C-1 (COMMERCIAL DISTRICT), ENTRANCE CORRIDOR AND AIRPORT IMPACT AREA OVERLAY DISTRICTS MAGISTERIAL DISTRICTS: RIO SOURCE OF SURVEY, BOUNDARY, AND TOPOGRAPHY: FIRST ORDER, LLC 4383 HECKTOWN ROAD BETHLEHEM, PA 18020 JACK W. SHOEMAKER, L.S. (610) 365-2907 JSHOEMAKER@FIRSTORDERLLC.NET MAY 24, 2018 DATUM: HORIZONTAL: NAD83 VIRGINIA STATE GRID SOUTH ZONE VERTICAL: NAVD88 (PER GPS OBSERVATIONS AND UTILIZING HTTPS://WWW.NGS.NOAA.GOV/OPUS/) UTILITIES: RSCA SANITARY AND WATER SERVICE. FIRE HYDRANTS: THERE IS ONE FIRE HYDRANT LOCATED AT THE EASTERN CORNER OF THE SITE AND. WATERSHED: MEADOW CREEK WATERSHED - NOT A WATER SUPPLY WATERSHED. ZONING SITE REQUIREMENTS: SETBACKS REQUIRED PROPOSED FRONT MIN: 10' MAX: NONE* 10' SIDE/REAR MIN: PER BUILDING CODE MAX: NONE 3' *PROPERTY ABUTS A PRINCIPAL ARTERIAL HIGHWAY USE PRESENT: ABANDONED PARKING LOT PROPOSED: 6,816 SF COMMERCIAL/RETAIL BUILDING MAXIMUM ALLOWABLE BUILDING HEIGHT: 65' PROPOSED BUILDING HEIGHT: 21'-0" PARKING TOTAL EXISTING PARKING: 70 SPACES, 4 ADA TOTAL REQUIRED PARKING: 53 SPACES MIN. (3) ADA SPACES, (1) OF WHICH MUST BE A, VAN SPACE GROSS FLOOR AREA (GFA) = 6,816 SF AUTOZONE RETAIL SALES AREA = 80% OF GFA = 5,452.80 SAF 1 SPACE 1100 SF RETAIL AREA (FOR FIRST 5,000 SF) 5,000 SF X 1 SPACE / 100 SF = 50 SPACES 1 SPACE / 200 SF RETAIL AREA (ABOVE 5,000 SF) 452.80 SF X 1 SPACE / 200 SF = 3 SPACES TOTAL PROPOSED PARKING: 55 SPACES, 3 ADA COMPLIANT, 2 OF WHICH ARE VAN ACCESSIBLE IMPERVIOUS AREA (WITHIN PROJECT LIMITS) EXISTING IMPERVIOUS AREA: 0.87 ACRES TOTAL POST DEVELOPED IMPERVIOUS AREA: 1.07 ACRES VEHICLE TRIP GENERATION FROM ITE TRIP GENERATION MANUAL 10TH EDITION USE: AUTOMOBILE PARTS SALES (843) AVERAGE RATE = 55.34 TRIPS PER 1000 SF GFA 6,816 SF GFA X 55.34 TRIPS / 1000 SF = 378 TRIPS/DAY DIRECTIONAL DISTRIBUTION: 50% ENTERING, 50% EXITING UTILITY DEMANDS WATER FLOW (AVERAGE DAILY DEMAND) AVERAGE FLOW RATES (FROM TABLE A 12VAC5-590-690, VDH WATERWORKS REGULATIONS): RETAIL: 250 GPD/1,000 SF = 6,816 SF X 250 GPD/1,000 SF =1,704 GPD TOTAL GPD = 1,704 GPD AVERAGE HOUR: 1,704 124 = 71 GALLONS PER HOUR MAX HOUR = 300% OF AVERAGE HOUR = 71 X 3 = 213 GALLONS PEAK DOMESTIC DEMAND = MAX HOUR X 2 = 213 X 2 = 426 GALLONS SEWER FLOW (AVERAGE DAILY FLOW) RETAIL: 6,816 SF X (250 GPD PER 1,000 SF) = 1,704 GPD TOTAL: 1,704 GPD L- 0 0 0 1 K aq GO[# INITIAL SITE PLAN ALBEMARLE COUNTY, VIRGINIA 12/14/2018 SITE LOCATION VICINITY MAP SCALE: 1" = 1000' OWNER: UNIVERSITY OF VIRGINIA FOUNDATION PO BOX 400218 CHARLOTTESVILLE, VA 22904-4218 TELEPHONE; (434) 982-4848 DEVELOPER: AUTOZONE, INC. 123 SOUTH FRONT ST MEMPHIS, TN 38103 CONTACT: KEVIN MURPHY TELEPHONE: (901) 495-7625 EMAIL: KEVIN.MURPHY@AUTOZONE.COM ENGINEER OF RECORD: TIMMONS GROUP 608 PRESTON AVE SUITE 200 CHARLOTTESVILLE, VA 22902 CONTACT: CLINT SHIFFLETT, P.E. TELEPHONE: (434) 327-1690 EMAIL: CLINT. SHIFFLETT@TIMMONS. COM Sheet List Table Sheet Number Sheet Title CO.0 COVER C0.1 SITE PLAN NOTES CO.2 s C1.0 SITE LAYOUT C1.A SITE DETAILS C13 SITE DETAILS C1.1 i VICINITY MAP SCALE: 1" = 1000' OWNER: UNIVERSITY OF VIRGINIA FOUNDATION PO BOX 400218 CHARLOTTESVILLE, VA 22904-4218 TELEPHONE; (434) 982-4848 DEVELOPER: AUTOZONE, INC. 123 SOUTH FRONT ST MEMPHIS, TN 38103 CONTACT: KEVIN MURPHY TELEPHONE: (901) 495-7625 EMAIL: KEVIN.MURPHY@AUTOZONE.COM ENGINEER OF RECORD: TIMMONS GROUP 608 PRESTON AVE SUITE 200 CHARLOTTESVILLE, VA 22902 CONTACT: CLINT SHIFFLETT, P.E. TELEPHONE: (434) 327-1690 EMAIL: CLINT. SHIFFLETT@TIMMONS. COM Sheet List Table Sheet Number Sheet Title CO.0 COVER C0.1 SITE PLAN NOTES CO.2 EXISTING CONDITIONS C1.0 SITE LAYOUT C1.A SITE DETAILS C13 SITE DETAILS C1.1 GRADING AND DRAINAGE PLAN C1.2 UTILITY PLAN C1.3 CONCEPTUAL STORMWATER MANAGEMENT PLAN D1.0 DEMOLITION PLAN L1.0 LANDSCAPE PLAN L2.0 LANDSCAPE NOTES & DETAILS TOTAL = 12 SHEETS SIGNATURE PANEL: DEPARTMENT OF COMMUNITY DEVELOPMENT: PLANNING & ZONING ENGINEERING INSPECTIONS ARCHITECTURAL REVIEW BOARD DEPARTMENT OF FIRE AND RESCUE ALBEMARtLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION HEALTH DEPARTMENT APPROVAL DATE Ln E r4 n, o M'i N, a >E w S C a ¢Uj U � U. —� Zoo w�o� z0U) ®°3 ro 0 0 -Ln _ En ko � w o N O b mo �m O J ow Ui O M L9 0 0 LU w z U d z 0 } 0 I - = F�IT, ;T r DATE 12/14/2018 DRAWN BY A. FONTAINE DESIGNED BY A. FONTAINE CHECKED BY C. SHIFFLETT SCALE N/A cn 0 _ < 0 co N _ 0 W a O Q u > LU 0 Q o z a \./ Lj O �0 LU <U) z aD O 0 o� to O E IZ _W CU N _ Q o U 0 0 z N O m � n � x < o0 73 �Q -_2 .7 Y N (B U c NO O U O �N �Q czo Dc D U cu O - C w70 'D JOB NO. U N o W U Jay -0 2 r��� N N C C O U SHEET NO. TCL o Co.0 -a E GENERAL NOTES 1. CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS FOR AS BUILT DOCUMENTATION, AS REQUIRED BY THE LOCALITY. THIS INCLUDES, BUT IS NOT LIMITED TO, TESTING, INSTALLATION DOCUMENTATION, SURVEY, ETC. ALL REQUIREMENTS SHALL BE DISCUSSED WITH THE LOCALITY PRIOR TO BEGINNING CONSTRUCTION. 2. ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS. 3. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES. 3. LAND USE PERMITS (LUP-A) MUST BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION PRIOR TO BEGINNING ANY CONSTRUCTION WITHIN THE EXISTING STATE MAINTAINED RIGHT OF WAY (INCLUDING ACCESS). 4. VDOT IS TO RECEIVE WRITTEN NOTIFICATION 48 HOURS PRIOR TO COMMENCING WITH INITIAL CONSTRUCTION ACTIVITIES. 5. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC, PRIOR TO CONSTRUCTION. 6. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE OWNER. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE OWNER'S REPRESENTATIVE, BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH SPECIFICATIONS. 7. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT STANDARDS. 8. ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN ACCORDANCE WITH ASTM -C-76. PIPE WITHIN THE RIGHT OF WAY SHALL BE MINIMUM CLASS III OR GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS. 9. IF PRE -CAST UNITS ARE TO BE USED, VDOT SHALL BE NOTIFIED AND THE MANUFACTURER SHALL SUBMIT DRAWING DETAILS FOR REVIEW. CERTIFICATION AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS. 10. ALL CONCRETE SHALL BE A3 -AE (AIR ENTRAINED 3,000 PSI), UNLESS OTHERWISE NOTED. 11. ALL ENTRANCES ARE TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CURRENT VDOT STANDARDS. 12. DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED AND APPROVED BY THE ENGINEER. 13. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON PLAN. IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN, CALL MISS UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001. THE OWNER SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING AND/OR PROPOSED RIGHT-OF-WAY REQUIRED BY THE DEVELOPMENT. 14. CASING SLEEVES SHALL BE PLACED AT ALL ROAD CROSSINGS FOR GAS, POWER, TELEPHONE AND CABLE TV SERVICE TRUNK LINES. (N/A) 15. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE. 16. VDOT & ALBEMARLE COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY. 17. VDOT SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF .ANY SURFACE COURSE(S). CONTACT THE OWNER'S REPRESENTATIVE FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 18. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE YARD (REC-250 PRIME COAT) PER, VDOT STANDARDS AND SPECIFICATIONS. 19. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE SPECIFICATIONS. 20. THE OWNER'S REPRESENTATIVE SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 21. A GEOTECHNICAL ENGINEER IS TO ASCERTAIN CAUSE AND CERTIFY RECOMMENDED METHOD OF REPAIR FOR ALL PAVEMENT STRUCTURAL FAILURES PRIOR TO STATE ACCEPTANCE. (N/A) 22. ALL VEGETATION AND ORGANIC MATERIAL IS TO BE REMOVED FROM THE PROPOSED PAVEMENT LIMITS PRIOR TO CONDITIONING OF THE SUBGRADE. 23. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR ALL MATERIALS AND BE IN ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICATIONS, AND ROAD AND BRIDGE STANDARDS. 24. APPROVAL OF A DETAILED CONSTRUCTION SEQUENCING/MAINTENANCE OF TRAFFIC NARRATIVE FOR THE WORK ZONE IS A PREREQUISITE FOR ISSUANCE OF A LAND USE PERMIT ALLOWING ACCESS TO AND CONSTRUCTION WITHIN VDOT MAINTAINED RIGHT OF WAY. (N/A) 25. GRADE LINES ON PROFILES DENOTE FINISHED GRADE OF CENTER LINE OF ROAD. (N/A) 26. ALL APPROACH GUTTERS TO SAG INLETS SHALL MAINTAIN A MINIMUM SLOPE OF 0.004 ft./ft. 27. WHERE A TYPE "B" NOSE IS SPECIFIED ON AN INLET IN CONJUNCTION WITH ROLL FACE CURB AND GUTTER OR CG -7, THERE SHALL BE A 20' TRANSITION ON EACH SIDE OF THE INLET. (NIA) 28. CONTRACTOR SHALL PROVIDE A SEQUENCE OF CONSTRUCTION/MAINTENANCE OF TRAFFIC PLAN IN ACCORDANCE WITH THE STANDARDS AND GUIDELINES CONTAINED IN THE 2011 EDITION OF THE VIRGINIA WORK AREA PROTECTION MANUAL FOR REVIEW BY THE ENGINEER, OWNER'S REPRESENTATIVE, AND VDOT PRIOR TO STARTING WORK THAT IMPACTS TRAFFIC ON STATE ROADS. 29. ALL NEW HANDICAP ACCESSIBLE REQUIREMENTS ON-SITE AND WITHIN ALL NEW STRUCTURES SHALL COMPLY WITH THE 2006 UNIFORM STATEWIDE BUILDING CODE, 2006 VIRGINIA CONSTRUCTION CODE, AND ICCIANSI Al 17.1-03. 30. THE CLEAR ZONE IS TO BE FREE OF STORED MATERIALS AND PARKED EQUIPMENT. 31. HORIZONTAL AND VERTICAL SIGHT DISTANCES SHALL BE FREE OF PARKED VEHICLES. 32. ALL EXCAVATED AREAS WITHIN THE CLEAR ZONE THAT HAVE A DEPTH GREATER THAN 61, SHALL HAVE A 6:1 STONE WEDGE PLACED AT THE END OF THE DAY 33. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT OF WAY INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA, DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS Q Q MENTS OF THE PERMIT SHALL GOVERN. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT. 3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND MUST BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL:VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. - O STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION 6. PAVED, RIP RAP R A Q INION OF OR DESIGNEE IT IS DEEMED NECESSARY IN ORDER TO STABILIZE THE COUNTY ENGINEER, E A DRAINAGE CHANNEL. 7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 8. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS III. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). ALBEMARLE COUNTY STORMWATER MANAGEMENT NOTES 1. ALL DAMS AND CONSTRUCTED FILL TO BE WITHIN 95% OF MAXIMUM DRY DENSITY AND 2% OF OPTIMUM MOISTURE CONTENT. ALL FILL MATERIAL TO BE APPROVED BY A GEOTECHNICAL ENGINEER. A GEOTECHNICAL ENGINEER IS TO BE PRESENT DURING CONSTRUCTION OF DAMS. 2. PIPE AND RISER JOINTS ARE TO BE WATERTIGHT WITHIN STORMWATER MANAGEMENT FACILITIES. 3. FOR TEMPORARY SEDIMENT TRAPS OR BASINS WHICH ARE TO BE CONVERTED TO PERMANENT STORMWATER MANAGEMENT FACILITIES; CONVERSION IS NOT TO TAKE PLACE UNTIL THE SITE IS STABILIZED, AND PERMISSION HAS BEEN OBTAINED FROM THE COUNTY EROSION CONTROL INSPECTOR. L on 1511 01 0.0 2 1.040 SEDIMENT CONTROL 1. THE PLAN APPROVING AUTHORITY MUST BE NOTIFIED ONE WEEK PRIOR TO THE PRE -CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO THE FINAL INSPECTION. 2. ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS. 3. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE FIRST STEP IN CLEARING. 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFF-SITE BORROW OR WASTE AREAS), THE CONTRACTOR SHALL SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND APPROVAL BY THE PLAN APPROVING AUTHORITY. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE PLAN APPROVING AUTHORITY. 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 8. DURING DEWATERING OPERATIONS, WATER WILL BE PUMPED INTO AN APPROVED FILTERING DEVICE. 9. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 10. ALL FILL MATERIAL TO BE TAKEN FROM AN APPROVED, DESIGNATED BORROW AREA. 11. ALL WASTE MATERIALS SHALL BE TAKEN TO AN APPROVED WASTE AREA. EARTH FILL SHALL BE INERT MATERIALS ONLY, FREE OF ROOTS, STUMPS, WOOD, RUBBISH, AND OTHER DEBRIS. 12. BORROW OR WASTE AREAS ARE TO BE RECLAIMED WITHIN 7 DAYS OF COMPLETION PER ZONING ORDINANCE SECTION 5.1.28. 13. ALL INERT MATERIALS SHALL BE TRANSPORTED IN COMPLIANCE WITH SECTION 13-301 OF THE CODE OF ALBEMARLE. 14. BORROW, FILL OR WASTE ACTIVITY INVOLVING INDUSTRIAL -TYPE POWER EQUIPMENT SHALL BE LIMITED TO THE HOURS OF 7:OOAM TO 9:OOPM. 15. BORROW, FILL OR WASTE ACTIVITY SHALL BE CONDUCTED IN A SAFE MANNER THAT MAINTAINS LATERAL SUPPORT, OR ORDER TO MINIMIZE ANY HAZARD TO PERSONS, PHYSICAL DAMAGE TO ADJACENT LAND AND STRUCTURES/IMPROVEMENTS, AND DAMAGE TO ANY PUBLIC STREET BECAUSE OF SLIDES, SINKING, OR COLLAPSE. 16. THE DEVELOPER SHALL RESERVE THE RIGHT TO INSTALL, MAINTAIN, REMOVE OR CONVERT TO PERMANENT STORMWATER MANAGEMENT FACILITIES WHERE APPLICABLE ALL EROSION CONTROL MEASURES REQUIRED BY THIS PLAN REGARDLESS OF THE SALE OF ANY LOT, UNIT, BUILDING OR OTHER PORTION OF THE PROPERTY. 17. TEMPORARY STABILIZATION SHALL BE TEMPORARY SEEDING AND MULCHING. SEEDING IS TO BE AT 75 LBS/ACRE, AND IN THE MONTHS OF SEPTEMBER TO FEBRUARY TO CONSIST A 50/50 MIX OF ANNUAL RYEGRASS AND CEREAL WINTER RYE, OR IN MARCH AND APRIL TO CONSIST OF ANNUAL RYE, OR MAY THROUGH AUGUST TO CONSIST OF GERMAN MILLET. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 18. PERMANENT STABILIZATION SHALL BE LIME AND FERTILIZER, PERMANENT SEEDING, AND MULCH. AGRICULTURAL GRADE LIMESTONE SHALL BE APPLIED AT 90LBS/1000SF, INCORPORATED INTO THE TOP 4-6 INCHES OF SOIL. FERTILIZER SHALL BE APPLIED AT 10 LBS ACRE AND CONSIST OF A 10-20-10 U E 00 1 N TRI NT MIX. PERMANENT SEEDING SHALL BE APPLIED AT 180LBS/ACRE AND CONSIST OF 95% KENTUCKY 31 OR TALL FESCUE AND 0-5% PERENNIAL RYEGRASS OR KENTUCKY BLUEGRASS. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 19. MAINTENANCE: ALL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL EVENT. ANY DAMAGE OR CLOGGING TO STRUCTURAL MEASURES SHALL BE REPAIRED IMMEDIATELY. SILT TRAPS SHALL BE CLEANED WHEN 50% OF THE WET STORAGE VOLUME IS FILLED WITH SEDIMENT. ALL SEEDED AREAS SHALL BE RESEEDED WHEN NECESSARY TO ACHIEVE A GOOD STAND OF GRASS. SILT FENCE AND DIVERSION DYKES WHICH COLLECT SEDIMENT TO HALF THEIR HEIGHT MUST BE CLEANED AND REPAIRED IMMEDIATELY. 20. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS OF FINAL SITE STABILIZATION, WHEN MEASURES ARE NO LONGER NEEDED, SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 21. THIS PLAN SHALL BE VOID IF THE OWNER DOES NOT OBTAIN A PERMIT WTIHIN 1 YEAR OF THE DATE OF APPROVAL. (WATER PROTECTION ORDINANCE SECTION 17-204G.) 22. PERMANENT VEGETATION SHALL BE INSTALLED ON ALL DENUDED AREAS WITHIN NINE (9) MONTHS AFTER THE DATE THE LAND DISTURBING ACTIVITY COMMENCED. (WATER PROTECTION ORDINANCE SECTION 17-207B) ACSA GENERAL WATER & SEWER CONDITIONS 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE START OF THE WORK. 2. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND STRUCTURES, AS NECESSARY. 3. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS, AS ADOPTED BY THE ACSA. 4. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 6. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC 7. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 8. VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. 9. TREES ARE NOT PERMITTED IN THE ACSA EASEMENT. 10. THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO -LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE JANUARY 4, 2014 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT). ALL WATERLINES SEWER LINES AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. FIRE DEPARTMENT 1. BUILDING STREET NUMBERS SHALL BE PLAINLY VISIBLE FROM STREET. 2. A KNOXBOX KEY BOX SHALL BE MOUNTED TO THE SIDE OF THE FRONT OR MAIN ENTRANCE. LOCATION TO BE COORDINATED WITH THE FIRE MARSHAL'S OFFICE. 3. OVERHEAD WIRING OR OTHER OBSTRUCTIONS SHALL BE HIGHER THAN 13.5'. 4. AN APPROVED WATER SUPPLY DURING CONSTRUCTION SHALL BE MADE AVAILABLE AS SOON AS COMBUSTIBLE MATERIAL ARRIVES ON SITE. 5. IF THE FLOOR LEVEL OF THE HIGHEST STORY IS MORE THAN 30' ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS, THEN A CLASS I STANDPIPE SYSTEM MUST BE INSTALLED IN ADDITION TO THE SPRINKLER SYSTEM. 6. WHERE A BUILDING HAS BEEN CONSTRUCTED TO A HEIGHT GREATER THAN 50' OR FOUR STORIES, AT LEAST ONE TEMPORARY LIGHTED STAIRWELL SHALL BE PROVIDED UNLESS OR MORE PERMANENT STAIR ARE ERECTED AS THE CONSTRUCTION PROGRESSES. 7. BUILDINGS FOUR OR MORE STORIES IN HEIGHT SHALL BE PROVIDED WITH NOT LESS THAN ONE STANDPIPE OR USE DURING CONSTRUCTION. SUCH STANDPIPES SHALL BE INSTALLED WHEN THE PROGRESS OF CONSTRUCTION IS NOT MORE THAN 40' IN HEIGHT ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT ACCESS. SUCH STANDPIPE SHALL BE PROVIDED WITH FIRE DEPARTMENT HOSE CONNECTIONS AT ACCESSIBLE LOCATIONS ADJACENT TO USABLE STAIRS. SUCH STANDPIPES SHALL BE EXTENDED AS CONSTRUCTION PROGRESSES TO WITHIN ONE FLOOR OF THE HIGHEST POINT OF CONSTRUCTION HAVING SECURED DECKING OR FLOORING. 8. SMOKING TO BE ALLOWED IN ONLY DESIGNATED SPACES WITH PROPER RECEPTACLES. "NO SMOKING" SIGNS SHALL BE POSTED AT EACH BUILDING SITE AND WITHIN EACH BUILDING DURING CONSTRUCTION. 9. WASTE DISPOSAL OF COMBUSTIBLE DEBRIS SHALL BE REMOVED FROM THE BUILDING AT THE END OF EACH WORKDAY. 10, CUTTING AND WELDING. OPERATIONS INVOLVING THE USE OF CUTTING AND WELDING SHALL BE DONE IN ACCORDANCE WITH CHAPTER 35, OF THE VIRGINIA STATEWIDE FIRE PREVENTION CODE, ADDRESSING WELDING AND HOTWORK OPERATIONS. 11. FIRE EXTINGUISHERS SHALL BE PROVIDED WITH NOT LESS THAN ONE APPROVED PORTABLE FIRE EXTINGUISHER AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE COMBUSTIBLE MATERIALS HAVE BEEN ACCUMULATED, 12. REQUIRED VEHICLE ACCESS FOR FIRE FIGHTING SHALL BE PROVIDED TO ALL CONSTRUCTION OR DEMOLITION SITES. VEHICLE ACCESS SHALL BE PROVIDED WITHIN 100' OF TEMPORARY OR PERMANENT FIRE DEPARTMENT CONNECTIONS. VEHICLE ACCESS SHALL BE PROVIDED BY EITHER TEMPORARY OR PERMANENT ROADS, CAPABLE OF SUPPORTING VEHICLE LOADING UNDER ALL WEATHER CONDITIONS. VEHICLE ACCESS SHALL BE MAINTAINED UNTIL PERMANENT FIRE APPARATUS ACCESS ROADS ARE AVAILABLE. ALL PAVEMENT SHALL BE CAPABLE OF SUPPORTING FIRE APPARATUS WEIGHING 85,000LBS. 13. A PERMIT IS REQUIRED FOR FIRE LINE INSTALLATION. A DETAILED DRAWING (2 SETS) SHOWING FITTINGS AND THRUST BLOCKS MUST BE SUBMITTED WITH THE PERMIT APPLICATION. ONCE INSTALLED, THE FIRE LINE REQUIRES A VISUAL INSPECTION AND A PRESSURE TEST INSPECTION BY THE FIRE MARSHALL'S OFFICE. 14. FIRE HYDRANTS, FIRE PUMP TEST HEADER, FIRE DEPARTMENT CONNECTIONS OR FIRE SUPPRESSION SYSTEM CONTROL VALVES SHALL REMAIN CLEAR AND UNOBSTRUCTED BY LANDSCAPING, PARKING OR OTHER OBJECTS. LANDSCAPING IN THE AREA OF THESE ITEMS SHALL BE OF THE TYPE THAT WILL NOT ENCROACH ON THE REQUIRED FIVE FOOT RADIUS ON MATURITY OF THE LANDSCAPING. 15. NO VEHICLE/MACHINERY OF ANY TYPE, CONSTRUCTION MATERIALS OR CONSTRUCTION DEBRIS IS TO BE PARKED WITHIN 15 FT OF EITHER SIDE OR IN FRONT OF A FIRE HYDRANT, GENERAL NOTES 1, ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS. 2, PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES. 3. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC, PRIOR TO CONSTRUCTION. 4. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE OWNER. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE OWNER, BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH CURRENT. 5. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT I AND I LD -94 (D) 121.13. 6. ALL RCP STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN ACCORDANCE WITH ASTM -C-76. PIPE SHALL BE MINIMUM CLASS III OR GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS. 7. IF PRE -CAST UNITS ARE TO BE USED CERTIFICATION AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS. 8. ALL CONCRETE SHALL BE A3 -AE (AIR ENTRAINED 3,000 PSI), UNLESS OTHERWISE NOTED, 9. DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED AND APPROVED BY THE ENGINEER. 10.NT CO RACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON PLAN. IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN, CALL MISS UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001. 11. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE, 12. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE YARD (REC-250 PRIME COAT) PER VDOT STANDARDS AND SPECIFICATIONS. 13. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES S SHALL ACCOMMODATE FORECAST WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE SPECIFICATIONS. 14. THE OWNERS REPRESENTATIVE SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 15. ALL VEGETATION AND ORGANIC MATERIAL MATERIAL IS TO BE REMOVED FROM THE PROPOSED PAVEMENT LIMITS PRIOR TO CONDITIONING OF THE SUBGRADE. 16. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO THE OWNER FOR ALL MATERIALS AND BE IN ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICATIONS, AND ROAD AND BRIDGE STANDARDS. 17. ALL NEWHANDICAP ACCESSIBLE REQUIREMENTS ON- SITE AND WITHIN ALL NEW STRUCTURES SHALL COMPLY WITH THE 2006 UNIFORM STATEWIDE BUILDING CODE, 2012 VIRGINIA CONSTRUCTION CODE, AND ICC/ANSI A117,1-03. 18. HORIZONTAL AND VERTICAL SIGHT DISTANCES SHALL BE FREE OF PARKED VEHICLES, SITE PLAN LEGEND AL I RENNIARLE COUNTY FINAL PLAN GENERAL NOTES General Construction dotes 11101001,= 1 0 0 f w EXISTING G PROPERTY LINE POST/BOLLARD SIGN ":.'-•,:. BUMPER BLOCK COMM DUCT BANK SATELLITE DISH ELECTRIC DUCT BANK TRAFFIC CONTROL BOX CATCH BASIN UNKNOWN MANHOLE ..............__......... ..... .... STORM SEWER SANITARY MANHOLE STORM SEWER MANHOLE CATCH BASIN SANITARY CLEAN OUT CATCH BASIN WITH DOME GRATE FIRE HYDRANT TRENCH DRAIN _, ...,..._ ......... .::.:,;......._ .............. SANITARY SEWER METER SANITARY SEWER MANHOLE _...:...::: .......................... WATER LINE WATER VALVE WATER MANHOLE GAS VALVE WATER VALVE BOLLARD WATER LINE MARKER STREET SIGN FIRE HYDRANT GAS METER MONITORING WELL LIMITS OF DISTURBANCE GAS LINE GUARDRAIL GAS METER X GAS VENT XXX GAS MARKER - - - COMMUNICATIONS/TELEPHONE LINE �. TELEPHONE/COMMUNICATIONS MANHOLE XO TELEPHONE PEDESTAL LU M c - P- E COMMUNICATIONS VAULT _...,.. _...._,;;:: ; .»._.. »»........... ELECTRIC LINE ELECTRIC MANHOLE ELECTRIC PULLBOX ELECTRIC METER UTILITY POLE DECIDUOUS TREE .......:............::.............>:.............::......... GUARDRAIL FENCE MAJOR CONTOUR MINOR CONTOUR SOIL BORING SURVEY CONTROL MONUMENT SURVEY CONTROL POINT AL I RENNIARLE COUNTY FINAL PLAN GENERAL NOTES General Construction dotes 11101001,= 1 0 0 f w WATER G GAS STORM SAN Om SANITARY UGT COMM DUCT BANK UGP ELECTRIC DUCT BANK ® CATCH BASIN SDC)E STORM MANHOLE SANITARY MANHOLE O SANITARY CLEAN OUT 1W-} FIRE HYDRANT ~ FDC -CD- METER SETBACK - AT/FP STANDOFF ® WATER VALVE 0 GAS VALVE O BOLLARD -�- STREET SIGN ❑ GAS METER LIMITS OF DISTURBANCE GUARDRAIL X FENCE XXX MAJOR CONTOUR XXX MINOR CONTOUR �. SITE LIGHT XO PARKING SPACE COUNT f D A nTnIr TC =TOP OF CURB BC = BOTTOM OF CURB EP = EDGE OF PAVEMENT EC = EDGE OF CONCRETE TW = TOP OF WALL BW = BOTTOM OF WALL TS = TOP OF STAIRS BS = BOTTOM OF STAIRS N/A = NOT APPLICABLE TO THIS PROJECT . lir or to any construction within any existing public right -of- a jii ludirlg connection to any existing read; a permit shall be obtai ed .1r rn. the Virginia (" e artr-nirt: of Trat`a o.rtatior� " OT` . This plan a dra n. may not accurately reflect the req r;ir i r. -Its of l � � l� ' M 1. the perniut. Where any discrepanciesoccur the requirenients of the permit shall govern.. 1 All rmaterialsarad construction nietho&..,, shall c .,artrn). to ciiiaetrt ,. ecrttcations and standards of VDOT unless otherwise noted, .:. h'r��ir~� 9�tltatic ra ��i�tri l measures shall lir.' provided i.n: accordance wrth the approved erosion control play and shall be nst .11ed prior to any clearing, grading or other construcition. All slopes, and Ali tur d a.r as are to be fertilized, seeded and mulched. a �. Tlr�. �, ii�rtra��t allo��ahl slope r 2,,l hora;��ntal..�l�:rtr:�:A�1, . Where a�-a.���:�ahl � ara�a l lesser slopes of 3.1 or better are to he achieved.. , Paved rip -rap or stah%tgat on mat lined. ditch may he required when in the opinion of the County Eng,' artier, r designee, it is deemed necessary in order to stabilize a drainage channel. 1. 7. All tra t i control signs shall conform with the.r inia Manual for Uniform Traffic Control Devices, 8. Unless oitherwiae rioted all concrete pipe, shall be reinforced concrete pile=, - t*..laS lll. 9, All xc a: atiolr for underground pipe nstallatio .must curnply With OSHA Standards car this ���JI1:�(ruc ion 1ndu�tl � (29 CFR :art 1926), U) DATE 12/14/2018 O URANIN BY A. FONTAINE DESIGNED BY A. FONTAINE I = CHECKED BY C. SHIFFLETT SCALE N/A N LU _ U _ O to 0 Q a LLj 0 0 < Uj o _ O N z o U o LU C <C - w ]. j� 0 m 2� � o c� LU < 2z v0 �o �N Q U Z 0 N O 4 x o� Q 0 2� Qm to U N aa) O U U 3 v � �o � U ( O E g U t6 iB U JOB NO. N o N - CUqj U 42231 C N NC O O U SHEET NO. Q o Co. I W W �= J Ln E � o O M � c Q E Q -6.9 Z LU M c - P- E FLU U LU��b a LL o -1 LU O (D 0 cC B w ,a c��Y® L U a® z z = 1° � ~ o O Ln W Q) �® m w O U Of _j 00 oW O U ZD O W (D LU O W cC cl� LU w Q Q ® M O U) DATE 12/14/2018 O URANIN BY A. FONTAINE DESIGNED BY A. FONTAINE I = CHECKED BY C. SHIFFLETT SCALE N/A N LU _ U _ O to 0 Q a LLj 0 0 < Uj o _ O N z o U o LU C <C - w ]. j� 0 m 2� � o c� LU < 2z v0 �o �N Q U Z 0 N O 4 x o� Q 0 2� Qm to U N aa) O U U 3 v � �o � U ( O E g U t6 iB U JOB NO. N o N - CUqj U 42231 C N NC O O U SHEET NO. Q o Co. I W W �= I ......,,,,,.,.., ...:.:.::::::f..:: ............, ........ , } Al , , f .. ................... .. ....... i : ... ... ... .... ... ,s , ........ ......... ......... ......... ......... ......... ... .. :. :; .-,� ., 1, SCALE 1"=20' 0 20' 40' Ln E i A. FONTAINE CHECKED BY rq O 1 "=20' m n, c > Euj -,. AF- Q 0 3 ,L�;':� E �uj u _., .... LU M, f.. _... t7t ,::...., W;°®® o a I ......,,,,,.,.., ...:.:.::::::f..:: ............, ........ , } Al , , f .. ................... .. ....... i : ... ... ... .... ... ,s , ........ ......... ......... ......... ......... ......... ... .. :. :; .-,� ., 1, SCALE 1"=20' 0 20' 40' Ln E i A. FONTAINE CHECKED BY rq O 1 "=20' m n, c > Euj Q 0 3 E �uj u LU M, LLP® a CD W;°®® o a a)� 00 V)C) X W o Q U Qo Ln 2 0 w wCD �® > �N ui o m� r ,-i Cc (DL z 0 U U-1 � ZDo o w o_ - :D :D w O n LU LU Q r M 0 Q M z O Uy DATE 12/14/2018 O >- DRAWN BY A. FONTAINE N N LUU C N N O f � N N O Q O O_ T �6 LU O N zN O ✓ N s cu z r Qu(D o U.J <� 7 �� W �O o(5 LU Q2(voz s2i x 02i ! j � T F- 3 1 ® 0 O O N NO Q U 0 c 0 Z U) O� Q i x 0 0 O �? Q � U 61 U N �C O N U i (D,N O � U N 3= U Co O � S � :O 65 Q U JOB NO. u o 42231 N o � U SHEET NO. 0-2 CO.2 s E H DESIGNED BY A. FONTAINE CHECKED BY C. SHIFFLETT SCALE 1 "=20' N N LUU C N N O f � N N O Q O O_ T �6 LU O N zN O ✓ N s cu z r Qu(D o U.J <� 7 �� W �O o(5 LU Q2(voz s2i x 02i ! j � T F- 3 1 ® 0 O O N NO Q U 0 c 0 Z U) O� Q i x 0 0 O �? Q � U 61 U N �C O N U i (D,N O � U N 3= U Co O � S � :O 65 Q U JOB NO. u o 42231 N o � U SHEET NO. 0-2 CO.2 s E H Notes: 1. Install expansion joints in the curb at a maxiimum spacing of 20' o.c. 2. Landscaping materials, grass, sod, mulch, etc. shall be flush to I" below top of curb/paving/drainage openings. — NOTE THI5 DETAIL ONLY TO 5E USED AS NOTED ON SITE PLAN 4!# x111 (oil Pavement III—III—III=1.`�`,.>`�:: s surface a''w . Al .1I— DIMENSIION 4 TYPE Paving Area A B C D Drive Aisle 2" 2.5" 8'1 6'1 Parking 211 N/A 511 (O11 see note ° CHECKED BY pine framing —_ Trash Asphalt Topping (5M -9.5A) Binder Cc (5M-25.0> Type 215 Aggregat CompactE- 5ubgrade Compacted-/ ='III"III , I I I, , , I I � 1 '5 top 4 bottom subgrade I i I—i 1 NO SCALE NO SCALE 1 I CONCRETE VERTICAL CURB 2 1 ASPHALT PAVING SECTION D IMEN51ON 4 TYPE Concrete Section A B C 5tandard Dutq 5" 411 see note Duty (o11 411 see note —Heavy Dum ster/A roach Pad 6" 411 see note NOTE: Compactecl sulograde should lae as specified in soils report, 4000 P51 cone. paving (min.) w/ m wire mesh n Compacted x a X. b ` Aggregate base Q (Type 21A stone cover) o �' — _ n i CI 1= Compacted 5ubgrade NO SCALE 3 1 CONCRETE PAVING SECTION 4'x611 18'-0" CLEAR 811 x 8" x 1/8" Treated Pine 5'-011 81-011 51-011 Top of wall elevation. See site or grading enclosure plan Il N over treated s I" x 6" x 1/2" to hinge 4 gate post at 6'-011 O.C. MAX, spacing ° ° CHECKED BY pine framing —_ Trash Trash h O.D. tube. steel tube Dum ster 6- CY Dumpst (`Ij 6-$ CY � a u, U 6" ID. Steel to post. welded joints Treated 211x4" cont. 611 I.D. pipe field Post gate post welded 11.611 NOTE: A • ; � - 611 nom. I.D. 1 ,- "� Finishedrade varies. s g AND PIPES RED. Gates. See _ See grading plan with concrete detail, this 1 1/2" welded LU washer 8 1/2"x2"xl/4" Ill SAF to 3/4 bolt sheet latch plate with Latch plate w1 314" rounded edges 4" bolt handle NO SCALE 8 1 DUMPSTER LAYOUT Greenstreak Paving Cap Seal Profile x'610 - See specifications for additional information. z . ' 3/411 5awcut joint - fill with self leveling elastomeric sealant NOTE: SEE 51TE PLAN FOR 5PACING REQUIREMENT5 NO SCALE NO SCALE .4 1 TYPICAL EXPANSION JOINT 5 1 TYPICAL CONTROL JOINT Concrete slab 1:12 MAX 1:12 MAX HANDICAPPED m PAVEMENT 4"1 5YM50l_ (TYP.) 2" (SOLID BLUE) NO SCALE r, HANDICAP PARKING DETAIL 5/411 x 6 square ed ed treated pine boar& with 1/4" gap. Screw to frame Latch detail. with galvanized or See deta i 13 stainless steel screws !8'-0" CLEAR S'-111/2" i" --.. 8'-111]1" NOTE: lw rounded top. TURN DOWN 12" dia, hole filled with See bollard detail III I SLAB BETWEEN concrete LTJ WOOD POSTS. 1'-011 NO SCALE NO SCALE c3DUMPSTER SECTION WOOD 10 1 GATE DETAIL FOR DUMPSTER ENCLOSURE a 611 R. � 154 4"141, 211 of parking 1-1/4" O.D. hinge 6" Ig. Il III ill Alemite 1610-5L 811 x 8" x 1/8" hdraulic �rease —�\ fi ting to e gqusset plate SIDE ONLY) (INO.D. Top of wall elevation. See site or grading accessible for 111 1-1/4I All corners maintenance ` hinge 6" long I" weld tv 3" O.C. plan Il \ all around 4"x4" treated wood s I" x 6" x 1/2" to hinge 4 gate post at 6'-011 O.C. MAX, spacing W / CHECKED BY 3" x 1-1/4' Gate frame 211 x 211 x 1/6" s 5/4" x 611 treated O.D. tube. steel tube pine vertical boards Weld collar gate frame to post. welded joints Treated 211x4" cont. 611 I.D. pipe field horizontal nailers gate post welded 11.611 NOTE: to gate • ; PAINT ALL GATE FRAMES 611 nom. I.D. 1 ,- "� Finishedrade varies. s g AND PIPES RED. gate post filled _ See grading plan with concrete 1:12 MAX 1:12 MAX HANDICAPPED m PAVEMENT 4"1 5YM50l_ (TYP.) 2" (SOLID BLUE) NO SCALE r, HANDICAP PARKING DETAIL 5/411 x 6 square ed ed treated pine boar& with 1/4" gap. Screw to frame Latch detail. with galvanized or See deta i 13 stainless steel screws !8'-0" CLEAR S'-111/2" i" --.. 8'-111]1" NOTE: lw rounded top. TURN DOWN 12" dia, hole filled with See bollard detail III I SLAB BETWEEN concrete LTJ WOOD POSTS. 1'-011 NO SCALE NO SCALE c3DUMPSTER SECTION WOOD 10 1 GATE DETAIL FOR DUMPSTER ENCLOSURE a 611 R. � 154 4"141, 211 of parking 1-1/4" O.D. hinge 6" Ig. Il III ill III 11 II J NO SCALE �` Ill III 41. INT'L BARRIER FREE SYMBOL o A. FONTAINE 1I II N' A. FONTAINE MOUNT CANE 5OLT AND CHECKED BY Cane bolt GATE LATCH A55EM5LIE5 SCALE t9 THROUGH FACE 50ARDS" 1 -1/4" 6" MIN. O.D. tube collar , 01 I I I LL field I-1 i Cane bolt See detail welded 11.611 to gate Drill 118" hole in GATE LATCH / BOLT DETAILS NOTE: This drawing Handicap 5ign as required resents the minimum by Local an State ordinances represents mounted on face of building. 209 watt LED "D" foundation requirements*- if series area light more stringent drawing is K401CIAPr32 nstreak Fixture one per pole. shown in structural then it NOTE: ADDITIONAL 51GNAGE shall govern. 6, MAY BE REQUIRED (FINES I*AWM ETC.) CHECK WITH LOCAL Greenstreak Concrete walk w/ See site plan for GOVERNING AUTHORITIES X632 ACCOGNINZ radius 6x6-WI.4xW1.4 W.W.F. 15 lld pole and fixture II 5" s steel ole bronze max. �, ClA locations and II q p 2" square tube with Paving SLOPE 1/4 per FT. finish with 4 anchor bolts q d orientations. II closed top. (TO 5E 41- Light fixtures I) USED ONLY IF SIGN 15 — ' ...° ;• " Oa a -- -- --- -- -- --- -- -- -- -- ----- and oles are I `i NOT 5UILDING MOUNTABLE) s °_ - p I - �I ` =` E Note: - - II 1 it II �a 11 11 , 1 I 11 1 II furinished b I I z ><' :'+= I -0 U/2 11-01/211 5 -0 5 -0 5 -0 51-011 11-0 1/2 1-0 1/2 11-13/511 AutoZone and II Anchor bolts to be .4 installed b II installed perpendicular a t _ Comp. granular fill 1 General y (; to curb on single head N • �II�II— II 11- See specifications Buildin poles. Rotate 45 �i�ll II=III- 811 foundation V-5 1/4" Contractor. I I degrees to diamond II II 11= Note: 05 continuous T. 4 B. bolt pattern on dual = .� Dimension Height head poles. W Mounted on face of building. Q1 60"-12" above sidewalk 11 Mourned on Pole off building. 11 NO SCALE 80" minimum (Clear head room) 3/411 = I'-011 NO SCALE 5EC-6501_ 11 Nigh wind anchor bolts12 TYPICAL HANDICAP SIGN 13 TYPICAL RAISED WALK SECTION 14 5OLLARD LAA�OUT FLAN - &E�Lu2 II I"x36"x4" hook Standard Light pole base 11 anchor bolts a"x.176" hook SIDEWALK 3�4.,y TRUNCATED DOMES III PAVEMENT LANDING AREA cover insta 11 11 Smooth lactic red LANDING AREA 4' 3/4" # CfM*s, V4'-314" WIDE AND 314" -2 - over anchor II p r:r?� u - bolts j 1 sleeve. see spec. LANDW AREA � 40 p LANDINGS AREA O1 CENTER ARRANGED 60 THAT WATER WILL NOT ACCU111LATE. II Levelling nut (4 i Light pole 11 631 Steel Pipe filled 5' I b' I 5' MINIMUM I 6' I 5' locations)„, w/ cone. r r r r base plat I I SEE SITE Rolling overhead steel door PLaN NOTES: CR055 SECTION 3/4” chamfer (See plan and details) SIDE 1. RAMPS %HALL BE PAINTED THE SAME COLOR AS Topof Note: 51DEWA-K RAhP EXPANSION JOINT MATERAIL STRIPING THE AND TEXTURE SHALL BE Ii: l I ? II: Sealant paving r BIaILDING [ADJACENT TO BUILDING (iYP) SCORED GROOVE% Rub �If" ' Finish grade or top of I concrete 1: o paving, See site plan for Line of base smooth '' I l 2. THE BOTTOM OF THE RAMP SHALL HAVE A location block 1— 1� �— 0000000 MAX 1/4" LIP. ° . ° 111-1I1=11 1�1=11� °O°O°O°O -011 Pipe guard 'II=III III�II °O°O°o°o 1 l Door openinIII IIIm�3. CONST�T PER ADA STANDARDS. ° ° this sheet °MAX ° 24 dia. concrete base. Min. �. I 6 4 steel pipe set in ► oo } C)) C) ` 4. IF MAX %LOPE OF RAMP DOES NOT EXCEED 1:20 .... 1,' : reinforcing 4 "5 bars vert. 4 1 I 18"� hole felled with °° o o°o i THENt�COLOR ORTExtI ECONTRASTi%REaUIRED. concrete °°° °°°° 3 ties eq. space 0000 4 1. '..a O°O°O°O r 311 granular base 1 6' / I 5' MINIMUM Electric conduit i,_6" at bottom of hole L CENTER PIPE GUARDS ON EDGE OF OPENING LASING OPE SITE PLAN LANDING No SCALE No SCALE No SCALE Ar�A PLAN AREA 19 20' TYPICAL SINGLE LIGHT POLE 15 PIPE GUARD @ SERVICE DOOR 1(o TYPICAL PIPE GUARD SECTION CONCRETE ACCESSIBLE RAMP EXPANSION JOINTS 20'-0" oc. MAXIMUM 4 SPACES ,a 5'-0" oc. OR AS DIRECTED OR SHOWN ON THE: SITE PLAN EXIST GRADE METAL INSPECTION FRAME W/ SOLID LID 5 E LAYOUT 4 SITE IMPROVEMENT PLAN FOR ALTERNATE 5CORINC-4 FATTESN (NEENAH R-1975 OR EQUIVALENT) 3" CONCRETE COLLAR DUMMY JOINT( TTP.) " _ 6" X 6 1111.2xUJ1.2 WWF -� -CRUSHED STONE BEDDING z A '�w <:r ,', A 4' `°~ ^`.. DUMMY JOINT 41 1/2" EXPANSION JOINT 1/411 6" DI CLEANOUT -i ' }':`f • !� �..;.V'�; y.• WIT - SEALANT .:.y.. a. ILIR=1/6"{ Ayrk11 1/2" EXPANSION JOINT 1/2" EXPANSION JOINT 8" S" ROLLED GRAVEL BASE, PLUG AT END OF LINE V DUMMY JOINT } SEE SITE PLAN FOR CONTINUATION PLAN VIEW CURB OR GUTTER LINE SECTION A— A N.T.S. CLEANOUT DETAIL NO SCALE No Scale 18 I CONCRETE SIDEWALK In E space J NO SCALE 1211412018 0 NU INT'L BARRIER FREE SYMBOL o A. FONTAINE NOTE: N' A. FONTAINE MOUNT CANE 5OLT AND CHECKED BY Cane bolt GATE LATCH A55EM5LIE5 SCALE guide (2) THROUGH FACE 50ARDS" steel tub Gane bolt 3/4" INTO STEEL FRAME LL V cold rolled steel rod. Drill 118" hole in lop of slab slab. Size to fit bolt. CANE BOLT 1 1/2" welded LU washer 8 1/2"x2"xl/4" Ill SAF to 3/4 bolt latch plate with Latch plate w1 314" rounded edges 4" bolt handle 1-1/211 washer ___-) welded to __� ° 3/4" bolt bolt for stop STRIKE a stop bar 1-112"x6"x11411 bent Q IW v 3 FRONT plate strike with SIDE 1-3/4" dia, bolt through frame DOUBLE GsATE LATCH NO SCALE GATE LATCH / BOLT DETAILS NOTE: This drawing Handicap 5ign as required resents the minimum by Local an State ordinances represents mounted on face of building. 209 watt LED "D" foundation requirements*- if series area light more stringent drawing is K401CIAPr32 nstreak Fixture one per pole. shown in structural then it NOTE: ADDITIONAL 51GNAGE shall govern. 6, MAY BE REQUIRED (FINES I*AWM ETC.) CHECK WITH LOCAL Greenstreak Concrete walk w/ See site plan for GOVERNING AUTHORITIES X632 ACCOGNINZ radius 6x6-WI.4xW1.4 W.W.F. 15 lld pole and fixture II 5" s steel ole bronze max. �, ClA locations and II q p 2" square tube with Paving SLOPE 1/4 per FT. finish with 4 anchor bolts q d orientations. II closed top. (TO 5E 41- Light fixtures I) USED ONLY IF SIGN 15 — ' ...° ;• " Oa a -- -- --- -- -- --- -- -- -- -- ----- and oles are I `i NOT 5UILDING MOUNTABLE) s °_ - p I - �I ` =` E Note: - - II 1 it II �a 11 11 , 1 I 11 1 II furinished b I I z ><' :'+= I -0 U/2 11-01/211 5 -0 5 -0 5 -0 51-011 11-0 1/2 1-0 1/2 11-13/511 AutoZone and II Anchor bolts to be .4 installed b II installed perpendicular a t _ Comp. granular fill 1 General y (; to curb on single head N • �II�II— II 11- See specifications Buildin poles. Rotate 45 �i�ll II=III- 811 foundation V-5 1/4" Contractor. I I degrees to diamond II II 11= Note: 05 continuous T. 4 B. bolt pattern on dual = .� Dimension Height head poles. W Mounted on face of building. Q1 60"-12" above sidewalk 11 Mourned on Pole off building. 11 NO SCALE 80" minimum (Clear head room) 3/411 = I'-011 NO SCALE 5EC-6501_ 11 Nigh wind anchor bolts12 TYPICAL HANDICAP SIGN 13 TYPICAL RAISED WALK SECTION 14 5OLLARD LAA�OUT FLAN - &E�Lu2 II I"x36"x4" hook Standard Light pole base 11 anchor bolts a"x.176" hook SIDEWALK 3�4.,y TRUNCATED DOMES III PAVEMENT LANDING AREA cover insta 11 11 Smooth lactic red LANDING AREA 4' 3/4" # CfM*s, V4'-314" WIDE AND 314" -2 - over anchor II p r:r?� u - bolts j 1 sleeve. see spec. LANDW AREA � 40 p LANDINGS AREA O1 CENTER ARRANGED 60 THAT WATER WILL NOT ACCU111LATE. II Levelling nut (4 i Light pole 11 631 Steel Pipe filled 5' I b' I 5' MINIMUM I 6' I 5' locations)„, w/ cone. r r r r base plat I I SEE SITE Rolling overhead steel door PLaN NOTES: CR055 SECTION 3/4” chamfer (See plan and details) SIDE 1. RAMPS %HALL BE PAINTED THE SAME COLOR AS Topof Note: 51DEWA-K RAhP EXPANSION JOINT MATERAIL STRIPING THE AND TEXTURE SHALL BE Ii: l I ? II: Sealant paving r BIaILDING [ADJACENT TO BUILDING (iYP) SCORED GROOVE% Rub �If" ' Finish grade or top of I concrete 1: o paving, See site plan for Line of base smooth '' I l 2. THE BOTTOM OF THE RAMP SHALL HAVE A location block 1— 1� �— 0000000 MAX 1/4" LIP. ° . ° 111-1I1=11 1�1=11� °O°O°O°O -011 Pipe guard 'II=III III�II °O°O°o°o 1 l Door openinIII IIIm�3. CONST�T PER ADA STANDARDS. ° ° this sheet °MAX ° 24 dia. concrete base. Min. �. I 6 4 steel pipe set in ► oo } C)) C) ` 4. IF MAX %LOPE OF RAMP DOES NOT EXCEED 1:20 .... 1,' : reinforcing 4 "5 bars vert. 4 1 I 18"� hole felled with °° o o°o i THENt�COLOR ORTExtI ECONTRASTi%REaUIRED. concrete °°° °°°° 3 ties eq. space 0000 4 1. '..a O°O°O°O r 311 granular base 1 6' / I 5' MINIMUM Electric conduit i,_6" at bottom of hole L CENTER PIPE GUARDS ON EDGE OF OPENING LASING OPE SITE PLAN LANDING No SCALE No SCALE No SCALE Ar�A PLAN AREA 19 20' TYPICAL SINGLE LIGHT POLE 15 PIPE GUARD @ SERVICE DOOR 1(o TYPICAL PIPE GUARD SECTION CONCRETE ACCESSIBLE RAMP EXPANSION JOINTS 20'-0" oc. MAXIMUM 4 SPACES ,a 5'-0" oc. OR AS DIRECTED OR SHOWN ON THE: SITE PLAN EXIST GRADE METAL INSPECTION FRAME W/ SOLID LID 5 E LAYOUT 4 SITE IMPROVEMENT PLAN FOR ALTERNATE 5CORINC-4 FATTESN (NEENAH R-1975 OR EQUIVALENT) 3" CONCRETE COLLAR DUMMY JOINT( TTP.) " _ 6" X 6 1111.2xUJ1.2 WWF -� -CRUSHED STONE BEDDING z A '�w <:r ,', A 4' `°~ ^`.. DUMMY JOINT 41 1/2" EXPANSION JOINT 1/411 6" DI CLEANOUT -i ' }':`f • !� �..;.V'�; y.• WIT - SEALANT .:.y.. a. ILIR=1/6"{ Ayrk11 1/2" EXPANSION JOINT 1/2" EXPANSION JOINT 8" S" ROLLED GRAVEL BASE, PLUG AT END OF LINE V DUMMY JOINT } SEE SITE PLAN FOR CONTINUATION PLAN VIEW CURB OR GUTTER LINE SECTION A— A N.T.S. CLEANOUT DETAIL NO SCALE No Scale 18 I CONCRETE SIDEWALK In E DATE J 1211412018 0 NU o A. FONTAINE DESIGNED BY N' A. FONTAINE CHECKED BY C. SHIFFLETT SCALE 1 "=30' Q o LL �E LU F E Q IW v 3 L �4 C� LL u� >L °a ® o U, 4� � �0U-)Go IS QLU C) 0 ti U�® 0 w _ �Ln E ®cn v 5o >04 o w m® v ,-I CO ti ® j 0 0 0 _ V) L1.1 0 r L w w *1 U M Z 0 Ui DATE 1211412018 0 DRAWN BY A. FONTAINE DESIGNED BY A. FONTAINE CHECKED BY C. SHIFFLETT SCALE 1 "=30' N U N 42 INN -4 > 2- 0 VJ C „ UJ 2 9 < 0 _J > U) z r U LU LliJ N LU :3O ED o(D _1 ,z U) LJJ 2 (Do 22i 0 2 c 7+ H 0 O :_ t) N 11 U 0 2 D 4 x `o Q� 0 >i o '� co N U X � 0 0 U U L m � 0 , o 0 E-0 c U t6 O ® 7 C s U JOB NO. u o N .— (6 U 42231 cz Cn N p U SHEET NO. o_0 C I.AIn ,u := .E ■ 4 i ad TRANSITION BETWEEN d PIPE DIAMETERS WHEN DFFERENT SIZES OF PIPES ARE ENCOUNTERED. s NOTES: SHAPING OF MANHOLE AND INLET INVERTS IN ACCORDANCE WITH THIS DRAWING IS TO APPLY TO THOSE STRUCTURES SPECIFIED ON PLANS OR WHERE INVERT OF PIPE IS ABOVE INVERT OF STRUCTURE. MANHOLE OR DROP INLET IS TO BE FORMED AND CONSTRUCTED IN ACCORDANCE WITH APPLICABLE STANDARD OR SPECIAL DRAWING. SHAPE TO ELEVATION OF MID -POINT OF LARGEST PIPE. 7I 1 SHAPE TO CONTOUR 1 J OF PIPE ( I i < 4 SLOPE TO DRAIN TO INVERT \ OF OUTLET PIPE SECTION A -A METHOD OF TREATMENT IN DROP INLETS SLOPE TO DRAIN TO INVERT OF OUTLET PIPE THE INVERT SHAPING AS DETAILED H t/ EREON IS TO CONSIST OF A PORTLAND CEMENT CONCRETE MIX CONFORMING TO CLASS A3 OR CLASS C1, EXCEPT THAT 25X OF COARSE AGGREGATE MAY BE UP TO 4" IN DIAMETER AND CONSIST OF STONE, BROKEN BRICK, c BROKEN CONCRETE OR BROKEN CONCRETE BLOCK. THE SURFACE SHALL BE LEFT SMOOTH BY MEANS OF HAND TROWELLING. NONE OF THE COARSE AGGREGATE SHALL REMAIN EXPOSED, as " DETAILS OF INVERT SHAPING AS SHOWN HEREON ARE FOR EXAMPLE a d PURPOSES ONLY, EACH MANHOLE OR DROP INLET IS TO BE SHAPED INDIVIDUALLY TO BEST FIT THE PARTICULAR INLET AND OUTLET CONFIGURATION AND FLOW LINES. SECTION B -B PLAN METHOD OF TREATMENT IN MANHOLES v�rr STANDARD METHOD OF SHAPING SPECIFICATION ROAD AND BRIDGE STANDARDS SHEET 1 OF 1 REVISION DATE MANHOLE &INLET INVERTS 302 706.08 VIRGINIA DEPARTMENT OF TRANSPORTATION REFERENCE PB -1 NO PROJECTION OF PIPE ABOVE GROUND LiNE MINIMUM RAMP LENGTH FEET 4" CURB 6" CURB TOP OF FILL - TOP OF FILL TOP OT FILL -------- -------- ----- -- -r GROUND I INE _ ---- ----- ------ 1-71 2 t Fx ------ - ----�-- r GROUND LINE _ --_---- --- ---- _ I = III !- EARTH I�,- •c -J I, '- rrr( r (-IROCK OR - UNYIELDING I III --i ,EARTH t rr'r A / rr, I- `�:C 72 z .1 MAX m < SOIL S i I o I MiDJ. BEDDING MATERIAL 12:1 MAX - N MIN. t/10 D- �: X D X BEDDING MATERIAL p 1!10 D i �.. X 1 0 X -BEDDING MATERIAL MIN. 1/10 D -1 1 - _ - --- ,C s --D----- / Y'3Y �I�: /z" PER V OF H THE REQUIRED LENGTH OF A PARALLEL RAMP TYPICAL PLACEMENT MIN, 8", MAX. 24" FOUNDATION SOFT, YIELDING, OR NORMAL EARTH FOUNDATION ROCK FOUNDATION OTHERWISE UNSUITABLE MATERIAL PIPE PROJECTION ABOVE GROUND LINE MLN. L5 x D MIN- L5 x D MIN. 1.5 x DMIN. 1.5 D ---- TOP OF FILL -- -- --- -- MIN. 1.5 :< ID MIN. 7.5 x D - _-__-- TOP OF FILL TOP OF FILL - ,ter 1 -- .:..... rrr- rr`%r, lr� r FOR DETAILS rr : 2 v --- -rr -- - --- ��;•� GROUND + lj riri NE '- _ += -GROUND - ;:, �'�- d Cr : -- LINE ----- - - + _ - rrrrr; ;� d _ 1; rr ter, err GROUND 2.2 0.970 LINE- III- . -:-III ISI H DEARTH _- ROCK OR MIN. 1/10 G - - UNYIELDING III III- III-=, I�c .' ' •, IiI: ( _-- MIN. 11 iC D X U Xi BEDDING - MATERIAL PER _ SOIL 1" OF H X_ D X MIN. I/10 D .p .__BEDDING �__ EARTH WITH BUFFER STRIP MIN. 8", BE DD?NG MAx. 24" MATERIAL MATEii!A�- FOUNDATION! SOFT, YIELDING, OR NORMAL EARTH FOUNDATION ROCK FOUNDATION OTHERWISE UNSUITABLE MATERIAL BEDDING MATERIAL IN ACCORDANCE WITH EMBANKMENT SECTION 302 OF THE ROAD AND BRIDGE NOTES: SPECIFICATIONS. FOR GENERAL NOTES ON PIPE BEGGING, CLASS I B.ACKFiLL MATERIAL IN ACCORDANCE SEE INSTALLATION OF PIPE AL NO RTS WITH SECTION 302 OF THE ROAD AND BRIDGE ANDI STORM SEWERS GENERAL :DOTES SPECIFICATIONS. I ONSHEET 1L 0 D . OYS. REGULAR BACKFLL MATERIAL. W ACCORDANCE • - FOR PLASTIC PIPE CLASS I BACKFILL MATERIAL WITH SECTION 302 OF THE ROAD AND BRIDGE CRUSHED GLASS CONFORMING TO THE SECTION SPECIFICATIONS. SIZE: FOR W ACCORDANCE WITH 302 OF THE ROAD REQUIREMENTS CRUSHER RUN AND BRIDGE SPECIFICATIONS. AGGiREGATE SIZE 25 AND 26 MAY BE USEID IN PLACE OF CLASS I BACKFILL. FOR ALL OTHER PIPE REGULAR BACKFILL MATERIAL IN ACCORDANCE WITH SECTION .302 OF THE ROAD AND BRIDGE SPECIFICATIONS. 1voclr INSTALL. OF PIPE CULVERTS AND STORM SEWERS SPECIFICATION REFERENCE ROAD AND BRIDGE STANDARDS (' CIRC. PIPE BEDDING AND BACKFILL METHOD "All 302 PLAN VIEW L N SHEET 1 OF 4 REVISION GATE 107.01 07/12 VIRGINIA DEPARTMENT OF TRANSPORTATION 303 ST -t #4, GRADE 160, REINFORCING ROD ENCASED IN NO. 6 GALVANIZED STEEL STEP MATERIALSION APPROVEDTBYT THE ENGINEERTHER (DIMENSION MAY VARY WITH MANUFACTURER'S DESIGN) kxlz CORROSION RESISTANT MATERIAL # 4 REINFORCING ROD TYPICAL SECTION sTFa /N �i �XOTh /4' 14" Da v %s" R TYPICAL SECTION A (DIMENSIONS MAY VARY WITH MANUFACTURER'S DESIGN) MINIMUM OF 3" EMBEDMENT ALUMINUM STEP STANDARD STEP VIRGINIA DEPARTMENT OF TRANSPORTATION NOTES: STEPS WILL BE REQUIRED IN AUL STRUCTURES WITH A DEPTH OF 4'-0" OR GREATER UNLESS OTHERWISE NOTED ON THE PLANS. ALL STEPS SHALL PROTRUDE 41/!2" FROM INSIDE FACE OF STRUCTURE WALL. MAXIMUM STEP SPACING TO BE 16" C -C. STEPS SHALIF WITHSTAND A MINIIMUM FORCE OF 300 POUNDS WHEN EXTENDED 4/2' FROM THE FACE: OF THE SUPPORT. STEPS ARE TO BE VERTICALLY ALIGNED AND UNiFORMALY SPACED FOR THE ENTIRE DEPTH OF ANY` STRUCTURE. IN PRECAST UNITS STEPS MAY IBE CAST IN PLACE, MORTARED INTO HOLES PROVIDED BY THE FABRICATOR OR DRIVEN. STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THEY MEET THE MINIMUM REQUIREMENTS SHOWN HEREON AND THE CONTRACTOR HAS FURNISHED THE ENGINEER WITH DETAILS AND CERTIFIED TEST REPORTS OF THE PROPOSED SUBSTITUTE AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. ALL STEPS INSTALLED SHALL BE: PROVIDED WITH SLIP -RESISTANT SURFACES SUCH AS BUT NOT UNITED TO, CORRUGATED KNURLED, OR DIMPLED SURFACES. ALUMINUM STEPS SHALL BE FABIRICATED IN ACCORDANCE WITH ASTM B221, ALLOY 6005-T5. THAT PORTION OF THE STEP ENCASED IN MASONRY SHALL BE UNIFORMLY COATED WITH A BITUMIMOUS, SOLVENT TYPE, ASBESTOS FILLED ALUMINUM PIGMENTED COATING CONFORMING TO FEDERAL SPECIFICATION TC -C -00498A. ROAD AND BRIDGE STANDARDS REVISION DATE SHEET 1 OF 1 106.09 CG -12 NODE; COMPONENTS OF CURB RAMPS CONSIST OF THE. FOLLOWING: HYDRAULIC CEMENT SIDEWALK (DEPTH IN INCHES, AREA IN SQUARE YARDS) CURB WHEN REQUIRED (CC -2 OR CG -3 IN LINEAR FEET) GENERAL NOTES: DETECTABLE WARNING SURFACE (AREA IN SQUARE YARDS) t. THE DETECTABLE WARNING SHALL BE PROVIDED BY TRUNCATED DOMES. EACH OF THE ABOVE ITEMS IS A SEPARATE PAY ITEM AND SHOULD BE SUMMARIZED FOR EACH CURB CUT RAMP. 2. DETECTABLE WARNPNC SHALL BE FROM THE MATERIALS APPROVED LIST FOR DETECTABLE PJARNING SUf ACES. PRODUCTS NOT LISTED SHALL MEET LEIJAL K- ,DAMP 72=1 MAX THE REQUIREMENTS OF THE SPECIAL PROVISION FOR CG -12 DETECTABLE �481 MAX WARNING SURFACE AND SHALL BE SUBMITTED TO THE STANDARDS AND SPFCIAL DESIGN SECTION FOR APPROVAL. 3, SLOPING SIDES OF CURB RAMP MAY BE POURED MONOLITHICALLY WITH RAMP 4' - FLOOR OR BY USING PERMISSIBLE CONSTRUCTION JOINT WITH REOUIRE.D BARS. 4. IF RAMP FLOOR IS PRECAST, HOLES MUST BE PROVIDED FOR DOWEL BARS `'0 "THAI" ADJOINING FLARED SIDES CAN BE CAST IN PLACE AFTER PLACEMENI" OF - - _____10:1 MAX PRECAST RAMP FLOOR. PRECAST CONCRETE SHALL BE CLASS A-4. TYPE A 5, REQUIRED BARS ARE TO BE NO.5 X 8" PLACED I- GENTER TO CENTER ALONG PERPENDICULAR BOTH SIDES OF THE RAMP FLOOR, MID -DEPTH OF RAMP FLOOR. MINIMUM CONCRETE COVER 111/2". 6. CURB I CURB AND GUTTER SLOPE TRANSITIONS ADJACENT TO CURB RAMPS /Y ✓�i�i�i�/ /✓ �. �/i i> ./' ' ARE INCLUDED !N PAYMENT FOR CURB / CURB AND GUTTER. 5, MIN ,l�- ���/l/ �i��� �/ Wil,/✓ Li/ii1 7. CURB RAMPS ARE TO BE LOCATED AS SHOWN ON THE PLANS OR AS DIRECTED;/�/` BY THE ENGINEER. THEY ARE TO BE PROVIDED AT INTERECTtONS WHEREVER AN ACCESSIBLE ROUTE WITHINTHE RIGHT OF 'NAY OF A HIGHWAY FACILITY CROSSES A CURB REGPRDI-ESS OF WHETHER SIDEWALK 13 EXISTING, PROPOSED, ' 0R NONEXISTENT. TH Y MUST BE LO CATED WITHIN PEUESFRIAN CROSSWALKS AS SHOWN ON PLANS 0R AS DIRECTED BY THE ENGINEER, JD SHOULD NOT TYPE B E i HT POLES FIRE ATS HIND VEHICLE STOP LINES, EXISTING LG BE LOCATED BE PARALLEL C A CONTINUOUS HYDRA':T R P tN TS ETC. ACCESSIBLE ROUTES PROVIDE C S D G LE UN ' OBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT PATH CONNECTING ALL / y11 -11.'N, ,.n 'y ` ACCESSIBLE ELEMENTS OF A FACILITY THAT CAN BE APPROACHED,ENTERED �T�yYl AND USED BY PEDESTRIANS. \ \ \.`; ✓ /�✓.,` �r ,: �,L,� ��" S. Y RAMPS MAY BE PLACED ON RADIAL OR TANGENTIAL SECTIONS PROVIDED THAT�,�-- E CUR OPENING IS PLACED WITHIN THE LIK4ITS OF THE CROSSWALK AND 12:114 AX THAT THE SLOPE AT THE CONNECTION OF THE CUR OPENING IS ---a- PERPENDICULAR TO THE CUR. -I 11=L -L -L=1 l-11:-11 _LLT- ! 9. TYPICAL CONCRETE SIDEWALK IS 4" THICK. WHEN THE ENTRANCE RADII C.4NtJOT ACCOMMODATE THE TURNING REQUIREMENTS OF ANTICIPATED HEAVY TRUCK Mtfd II_T._Lifif_!IiIIF_;I LII=T.u':- '•,%as°;g"s1,.::" TRAFFIC, REFER TO STANDARD CG -13, COMMERCIAL ENTRANCE (HEAVY 4 T11=:SHIP' - AT * 2" HIGHER THAN TRUCK TRAFFIC) FOR CONCRETE DEPTH. -� EDGE OFPAVEMENT 10. WHEN CURB RAMPS ARE USED IN CONJUNCTION WITH A SHARED USE PATH, AT.SAME AS TOP OF CURB THE MINIMUM WIDTH SHALL BE THE WIDTH OF THE SHARED USE PATH It'W'HEN ONLY ONE CURB RAMP IS PROVIDED FOR TWO CROSSINGS (DIAGONAL), TYPE C A 4'z 4'LA.NDING AREA. SHALL BE PROVIDED TO MANEUVER .A WHEELCHAIR PARALLEL & PERPENDICULAR WTO THE CROSSWALK WITHOUT GOING INTO THE TRAVELWAY. THIS 4'x 4' LANDING AREA MAY INCLUDE THE GUTTER PAN. TRUNCATED DOME �nI 12. .ALL CASES WHERE CURB RAMPS INTERSECT A RADIAL SECTION Of 16.._2 4" C -C CURB AT ENTRANCES OR STREET CONNECTIONS THE DETECTABLE - --- WARNING SURFACE SHALL HAVE A FACTORY RADIUS OR BE FIELD - �o--Eli `b O O O O O O �I -MODIFIED AS RECOMMENDED BY THE MANUFACTURER TO MATCH >� /,/)71) THE: BACK OF CURB. rD G G O U O 0 0 0 0 0 CJ O C, 0 0 0 0 0 0 0 G G 0 0 0 0 0 LANDING RAMP __ _ 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o f 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V N "tk°N•" j" �'J O U D O G O O G 0 0 U 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5_0/ 65Z OF BASE DIAMETER 0 0 0 0 0 O i TCP DIAMETER O O O D U U U U O DETECTABLE WARNIN\._ `- o. .____- � AT BACK OF CURB i (i.9"-14" VARIABLE FULL WIDTH OF RAJv!P fL00_P,--- SEE NOTE 12. '-� _ r BAST DIAMETER ^Y----- PAY LIMITS DETECTABLE WARNING TRUNCATED DOME DETECTABLE WARNING INSTALLED ON A RADIUS DETAIL DETAIL ZV(�ar CG -12 DETECTABLE WARNING SURFACE SPECIFICATION REF F_REDJCE. ROAD AND BRIDGE STANDARDS sh1EEr 1 OF s REv!s!oN DATE (GENERAL NOTES) 105 07115 VIRGINIA DEPARTMENT OF TRANSPORTA TION 502 203.05 '' ROADWAY GRADE . IN PERCENTIN MINIMUM RAMP LENGTH FEET 4" CURB 6" CURB 0 r2, CROSSWALK NItN #5 DOWELS, 8" LONG �� PERMISSIBLE 2 t Fx AT 12" C -C CONSTRUCTION 5' 6 9 12:1 MAX._ -- (n7 Tn1 II II 5 10 IS 0 �- I"' SUUtaRE L.'�:JD1�^1G AREA OUTSIDE NOF TRAVELWAY `�:C 72 z .1 MAX m < CROSSWALK CURB p / NOTES FOR GENERAL NOTES ON THE DETECTABLE WARNING SURFACE, 1 12:1 MAX - N WITHINPERPETHE WITHIN THE MARKED SEE SHEET 10F 5. f _t FF R TRIP W iTH BU E S / Y'3Y �I�: CROSSWALK AREA. THE REQUIRED LENGTH OF A PARALLEL RAMP TYPICAL PLACEMENT 1 2.223 8 RAMP �tRAMP IS LIMITED TO 15 FEET, REGARDLESS OF THEAT INTERSECTION ' �Y '"'+'T` -�� 2 5' MIN i -EE TABLE) TABS'RUPlCATED SLOPE. J ' (- A 0.785 12`1 DOMES SEE SHEET I OF 5 FOR DETAILS -MAX z,. %tJl 4 MN 3.455 12 2.2 0.970 5,-0" MIN 13 2.5 SHAPE TO MATCH FACE 4,179 OF ROADWAY CURB 2.8 WITH BUFFER STRIP BACK OF CURB- 48 1 MAX 3.1 v 20.1 48 !MAX, : 16 5. MIN -'mss":S L%" 1 0.970 1 5.265 77 121 MAX :m. 1.173 2' MIN. INCREMENT 0.45 NOTE; WIDTH "B" 2'-0" OR AS Ick MAINLINE ROADWAY SECTION A- Q EXCEPT FOR REPLACEMENT PURPOSES. SHOWN ON T'fPiCAt SECTION, A z PLAN VIEW L N ENTRANCE NOTES HE5. W:FN THE ENTRANCE RADII ACCOMMODATF _CANNOT T j -- `- WITHOUT BUFFER STRIP MAINLINE ROADWAY SLOPE ) PERMISSIBLE iC' PARABOLIC CURVE (ENTRANCE OPJL'f) r EDGE OF PAVe:ME.NT OR CONSTRUCTION 6. PLANS ARE TO INDICATE WHEN CONSTRUCTION OF A. FLOW ~ - , D - '-' (SEE r A PROVIDE POSITIVE DRAINAGE CROSS UNE IS REQUIRED TO OV DE OS _ MAINLINE ROADWAY - - - - -- - - - - NOTE 7) JOINT Ce I- CU Lf] �+ AX D 8% MAX. ---. _ DESIRABLE - ANC) MAXIMUM ENTRANCE GRADE CHANCES 7. 1"HE DE_I BLE GRADE CHANGE i -- - - D • , R 0 O U 1 ~ 0 !n :n O � INTERSECTION NOTES o. SECTION B CONNECTION MUST BE DESIGNED IN ACCORDANCE WITH AASHTO POLICY AND THE APPLICABLE REQUIREMENTS LL OF THE VDOT ROAD DESIGN MA.NUA; , INCLUDING STOPPING SECTION A _ A SIGHT DISTANCE AND K VALUE REQUIREMENTS. L CURB�� 0 '' ROADWAY GRADE . IN PERCENTIN MINIMUM RAMP LENGTH FEET 4" CURB 6" CURB 0 r2, CROSSWALK BRICK 7 2 5 8 MO 6 9 4 (n7 Tn1 II II 5 10 IS 0 �- I"' SUUtaRE L.'�:JD1�^1G AREA OUTSIDE NOF TRAVELWAY 0.50.78 CROSSWALK CURB p / SHf.LL BE PROVIDED FOR AR rRc SswnLK NOTES FOR GENERAL NOTES ON THE DETECTABLE WARNING SURFACE, 0.785 r� WITHINPERPETHE WITHIN THE MARKED SEE SHEET 10F 5. 0.785 / Y'3Y �I�: CROSSWALK AREA. THE REQUIRED LENGTH OF A PARALLEL RAMP TYPICAL PLACEMENT 1 2.223 8 - CURB 4'BUFFER STRIP IS LIMITED TO 15 FEET, REGARDLESS OF THEAT INTERSECTION 9 1.4 5'SII)ENALK SLOPE. 10 1.6 0.785 3.009 TYPE B PARALLEL APPLICATION ROADWAY GRADE . IN PERCENTIN MINIMUM RAMP LENGTH FEET 4" CURB 6" CURB 0 4 6 BRICK 7 2 5 8 3 6 9 4 8 12 5 10 IS 6 14 15 ROAD AND BRIDGE STANDARDS SHEET 3 OF 5 REVISION DATE 203.07 07116 WITHIN CROSSWALK LANDING 48; MAX, DIAGONAL PLACEMENT SLOPE LANDING 437 MAX. SLOPING 481 MAX, y, SL OPE l SLOE CURB MIN CURB o 11-11-110 CROSSWALKoxJ N 2. C' 7 R .' K � . OSS WAL a G ORn S - (_ I I 11 Lcuar9 CONCRETE CURB WITH BUFFER STRIP WITHOUT BUFFER STRIP CG -12 DETECTABLE WARNING SURFACE SPEGIFIGATIQPJ REFERENCE TYPE B (PARALLEL) APPLICATION 05 VIRGINIA DEPARTMENT OF TRANSPORTATION 502 SEE STANDARAD SL -1 FOR APPLICABILITY OF SAFETY SLABS. B STANDARD MH -1 NOTE: FRAME & COVER THE TOP OF MASONRY IS BE LEFT L SUFFICIENTLY LOW TO PERMIT T PROPER ! ADJUSTMENT OF COVER AND FRAME TO GRADE BY THE USE OF MORTAR OR BRICK AS DIRECTED BY THE ENGINEER. m zAmm im X11// ��� ��w le � 7J/l/sllrltwmm lll�. vwzlfmmmm 3A m mmr. i���i�� ■i0w6i wwm 'ii lemom -mmmm �a vyzA0w.m=m== • i i' HALF PLAN VIEW B ANEER. HALF SECTION A -A (WITH FRAME AND COVER REMOVED) BRICK CONCRETE NOTES: 45' 1. QUANTITIES SHOWN ARE FOR MANHOLE WITHOUT PIPES. THE AMOUNT DISPLACED BY PIPES MUST BE DEDUCTED TO MANHOLE FOR 12" - 4811 PiPE CULVERTS VIRGINIA DEPARTMENT OF TRANSPORTATION OBTAIN TRUE QUANTITIES. H 2. A BASE THICKNESS OF 9" WAS USED IN COMPUTING CONCRETE QUANTITIES. 3. INCREMENTS TO BE ADDED FOR EACH ADDITIONAL FOOT OF DEPTH. 4. MATERIALS MAY BE BRICK, CONCRETE OR APPROVEDCONCRETE MANHOLE BLOCK. 5. IF BLOCKS ARE USED THE MINIMUM THICKNESS OF SAME IS TO BE 5". OTHER THICKNESSES ARE TO CONFORM TO WALL THICKNESS SHOWN FOR CONCRETE. 6. ALL CONCRETE TO BE CLASS A3. 7. WHEN SPECIFIED ON PLANS THE INVERT IS TO BE SHAPED IN ACCORDANCE WITH STANDARD IS -1. THE COST OF FURNISHING AND PLACING ALL MATERIALS INCIDENTAL TO THE SHAPING IS TO BE INCLUDED IN THE BID PRICE FOR THE STRUCTURE. TABLE OF QUANTITIES NOTE: WHEN A PEDESTRIAN ACCESS ROUTE DEPTH BRICK MANHOLE CONCRETE MANHOLE THE CROSS SLOPE SHALL BE 2Z FOR BRICK CONCRETE CONCRETE FEET THOUS94DS CU. YARDS CU. YARDS 4 0.50.78 5 1.437 5 0.7 0.785 1.699 6 0.9 0.785 1.961 7 1.0 0.785 1 2.223 8 1.2 0.785 2.485 9 1.4 0.785 2.747 10 1.6 0.785 3.009 11 1.9 0,970 3.455 12 2.2 0.970 3.817 13 2.5 0.970 4,179 14 2.8 0.970 4.541 15 3.1 0.970 4.903 16 3.4 1 0.970 1 5.265 77 A.0 1.173 6.032 INCREMENT 0.45 NOTE; WIDTH "B" 2'-0" OR AS Ick MAINLINE ROADWAY 0.582 MANHOLE FOR 12" - 4811 PiPE CULVERTS VIRGINIA DEPARTMENT OF TRANSPORTATION OBTAIN TRUE QUANTITIES. H 2. A BASE THICKNESS OF 9" WAS USED IN COMPUTING CONCRETE QUANTITIES. 3. INCREMENTS TO BE ADDED FOR EACH ADDITIONAL FOOT OF DEPTH. 4. MATERIALS MAY BE BRICK, CONCRETE OR APPROVEDCONCRETE MANHOLE BLOCK. 5. IF BLOCKS ARE USED THE MINIMUM THICKNESS OF SAME IS TO BE 5". OTHER THICKNESSES ARE TO CONFORM TO WALL THICKNESS SHOWN FOR CONCRETE. 6. ALL CONCRETE TO BE CLASS A3. 7. WHEN SPECIFIED ON PLANS THE INVERT IS TO BE SHAPED IN ACCORDANCE WITH STANDARD IS -1. THE COST OF FURNISHING AND PLACING ALL MATERIALS INCIDENTAL TO THE SHAPING IS TO BE INCLUDED IN THE BID PRICE FOR THE STRUCTURE. CLASS A3 !% - • n. ;` -� (H. E. S.) CONCRETE SECTION C -C ENTRANCE VOLUME GRADE CHANGE ,.D= DESIRABLE MAXIMUM CG -11 NOTE: WHEN A PEDESTRIAN ACCESS ROUTE 3 % MEDIUM 500-1500 VPD CROSSES A COMERCIAL ENTRANCE 6 THE CROSS SLOPE SHALL BE 2Z FOR 5 6 % ' Y A WIDTH OF 5 FEET. APPROXMATE ONLY 2 A GENERAL NOTES --STREET AP. ROACIT SAME SURFACING I L 21{p" x 21/2' x NG 10'-4" LONG (RADIUS TO BE AS CI G AS MAINLINE ROADWAY (SEE NOTE 3) INLET (H) RE BE SHOWN 0' DEPTH FOR PLANS. FOR DEPTH GREATER THAN 1O USE SHOWN ON PLANS) in DESIGNED BY 1. WHEN USED IN CONJUNCTION WITH STANDARD CG -3 COLLAR WITH STANDARD IS -t. THE COST OF I (RADIUS TO BE AS OR CG -7, THE CURB FACE ON THIS STANDARD 15 TO CHECKED BY STANDARD DI -1A 5= SHOWN ON PLANS) BE ADJUSTED TO MATCH THE MOUNTABLE CURB SCALE CG -2 OR CG -6 CONFIGURATION. ` (SEE NOTE 1) >- - -- --- 2. SEE STANDARD CC -12 FOR CURB RAMP DESIGN TO BE LU SIDEWALK USED WITH THIS STANDARD. SI(SEE ( " I (SEE :,� - - - - NOTE 5) OPTIONAL UNPAVED SPACE 3. MAINLINE PAVEMENT SHALL BE CONSTRUCTED TO THE a w FLOW LINE R/ W LINE (EXCEPT ANY SUBGRADE STABILIZATION - - - -- --f, -1------- - REQUIRED FOR MAINLINE PAVEMENT WHICH CAN BE EXPANSION 9 0 EXPANSION OMITTED IN THE ENTRANCE.) JOINT A I - JOINT 4. RADIAL CURB OR COMBINATION CURB AND GUTTER, iJ. SHALL NOT BE CONSTRUCTED BEYOND THE R/W LINE NOTE; WIDTH "B" 2'-0" OR AS Ick MAINLINE ROADWAY EXCEPT FOR REPLACEMENT PURPOSES. SHOWN ON T'fPiCAt SECTION, A z PLAN VIEW L N ENTRANCE NOTES HE5. W:FN THE ENTRANCE RADII ACCOMMODATF _CANNOT T TURNING REQUIREMENTS OF ANTICIPATED HEAVY TRUCK MAINLINE ROADWAY SLOPE ) TRAFFIC, THE DEPTH FOR SOEINAL'K & CURB RAMPS WITHIN THE LIMITS OF THE RADIISHOULD BE iC' PARABOLIC CURVE (ENTRANCE OPJL'f) INCREASED TO 7". (SEE CG -13) EDGE OF PAVe:ME.NT OR 8% MAX. _-_---- D GRADE CHANGE -- -- - 6. PLANS ARE TO INDICATE WHEN CONSTRUCTION OF A. FLOW OPTIO^JAL FLOW LINE - , D - '-' (SEE r A PROVIDE POSITIVE DRAINAGE CROSS UNE IS REQUIRED TO OV DE OS _ MAINLINE ROADWAY - - - - -- - - - - NOTE 7) THE ENTRANCE. Ce I- CU Lf] �+ AX D 8% MAX. ---. _ DESIRABLE - ANC) MAXIMUM ENTRANCE GRADE CHANCES 7. 1"HE DE_I BLE GRADE CHANGE i -- - - D "D" .ARE LISTED IN THE ALLOWABLE ENTRANCE GRADE "TABLE. THESE VALUES ARE NOT APPLICABLE TO STREET ®CL o Go CONNECTIONS. ~ 0 20' MINitd_UM FOR COMMERCIAL ENTRANCE INTERSECTION NOTES S. WHEN CG -HIS USED FOR STREET CONNECTIONS, THE CONSTRUCT GRADE CHANGES VVI1"H A PARABOLIC CURVE. CONNECTION MUST BE DESIGNED IN ACCORDANCE WITH AASHTO POLICY AND THE APPLICABLE REQUIREMENTS LL OF THE VDOT ROAD DESIGN MA.NUA; , INCLUDING STOPPING SECTION A _ A SIGHT DISTANCE AND K VALUE REQUIREMENTS. 9. OPTIONAL FLOWUNE MAY REQUIRE WARPING OF A 0 4" RAINAGE PORTION OF GUTTER TO PROVIDE POSITIVE DRAINAGE-- C:) w dLn ACROSS THE INTERSECTION. ACROSS B ALLOWABLE ENTRANCE GRADE CHANGES CLASS A3 !% - • n. ;` -� (H. E. S.) CONCRETE SECTION C -C ENTRANCE VOLUME GRADE CHANGE ,.D= DESIRABLE MAXIMUM HIGH N40RE THAN 7500 VPD 0- - 1 3 % MEDIUM 500-1500 VPD <_ 3 % 6 LOW LESS THAN 500 VPD 5 6 % 3 LBS 1 NOTE: ALLOWABLE ENTRANCE GRACE TABLE IS NOT APPLICABLE TO STREET CONNECTIONS SPECIFICATION XVDOT REFERENCE METHOD OF TREATMENT ROAD AND BRUGE STANDARDS (CONNECTION FOR STREET INTERSECTIONS AND COMMERCIAL ENTRANCES) REVISION DATE SHEET 1 OF 1 50207/15 VIRGINIA DEPARTMENT OFTRANSPORTATION 20.3.04 2" R CG -6 NOTES: 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. F T IN PLACE BE CLASS A3 I CAS 2. CONCRETE 70 , 40 IF PRECAST. 00 PSI 3. COMBINATION CURB & GUTTER HAVING A RADIUS OF 300 FEET OR LESS (ALONG FACE OF CURB) SHALL BE PAID FOR AS RADIAL COMBINATION CURB & GUTTER. 4, FOR USE WITH STABILIZED OPEN -GRADED DRAINAGE LAYER,THE BOTTOM OF THE CURB & GUTTER SHALL BE CONSTRUCTED PARALLEL TO THE SLOPE OF SUBBASE COURSES AND TO THE DEPTH OF THE PAVEMENT. 5. ALLOWABLE CRITERIA FOR THE USE OF CG -6 IS BASED ON ROADWAY CLASSIFICATION AND DESIGN SPEED AS SHOWN IN APPENDIX A OF THE ROAD DESIGN MANUAL IN THE SECTION ON GS URBAN STANDARDS, • P 1..;1, P p D D -A A Q � D • - D D P P P D P P P D P D D D D p , P D THIS AREA MAY BE CONCRETE AT THE OPTION OF THE CONTRACTOR THE BOTTOM OF THE CURB AND GUTTER MAY BE CONSTRUCTED PARALLEL TO THE SLOPE OF SUBBASE COURSES PROVIDED A MINIMUM DEPTH OF 7" IS MAINTAINED. SPECIFICATION NV(-ij I REFERENCE COMBINATION 6" CURB AND GUTTER ROAD AND BRIDGE STANDARDS 105 REVISION DATE SHEET 1 OF t 502 VIRGINIA DEPARTMENT OF TRANSPORTATION 201.03 DI -1 %z SECTION CAST IRON -►�- %2 SECTION STEEL STANDARDS AND SPECIFIED ON THE PLANS NOTES WILL BE MEASURED FROM THE INVERT OF 66 ± 2'-7" 43.6 LBS ARE UCTURE. PLAN HFORMESTIMATINGG 3 LBS 1 APPROXMATE ONLY LUGS TO BE CAST WITH PURPOSES AND THE ACTUAL DIMENSIONS 1�=gJ �, L 21{p" x 21/2' x NG 10'-4" LONG 1. INLET (H) RE BE SHOWN 0' DEPTH FOR PLANS. FOR DEPTH GREATER THAN 1O USE .� m DESIGNED BY INVERT IS TO BE SHAPED IN ACCORDANCE COLLAR WITH STANDARD IS -t. THE COST OF FURNISHING AND PLACING ALL MATERIALS CHECKED BY STANDARD DI -1A A - A B µ N N OPTIONAL BRACE RIBS 6 4'-2" 112' x 1V' x 4' I %2' x 4" STRUCTURE. PLAN LUGS 12" 9�z' CSIUD SHEAR ONNECTORS 4• IN THE EVENT THE INVERT OF THE THE (GRATE REMOVED) BOTTOMS OF THE STRUCTURPIPE IS HIGHER E THE INVERT SEE DETAIL A -B>-� • -� OF THE STRUCTURE SHALL BE SHAPED WITH CEMENT MORTAR TO PREVENT SECTION B -B STANDING OR PONDING OF WATER IN THE N L!, STRUCTURE. THE COST OF FURNISHING /" AND PLACING ALL MATERIALS INCIDENTAL COLLAR DETAIL MIN RAISED UTTERING TO INLET SHAPING IS TO BE INCLUDED IN THE 810 PRICE FOR THE STRUCTURE. TO DIMENSIONS FOR DUMP NO WASTE DRAINS TO WATERWAYS 5. STEPS ARE GREBE FOR DETAILS SEE BE PROVIDED WHEN H IS G CAST IRON ONLY STANDARDST1 DETAIN•' B 6. THIS ITEM MAY BE PRECAST OR CAST - IN -PLACE. DETAIL A2'-6" 7. #4 X 8" SMOOTH DOWELS AT 4'-2" HARDWARE P_3+. SEE DETAIL B APPROXIMATELY 12" C -C TO BE 2'-7" CLOTH PLACED IN ALL AREAS ADJACENT /,r#8 4" DEPTH AGGR. i TO ABUTTING CONCRETE TO PREVENT #68, #78 ORniySETTLEMENT. 1N LIEU OF DOWELS w w ww 4.p, x 6" WIDTH \ A 2"X4" NOTCH MAY BE PROVIDED, (L 0. a (L _ !j SEE STANDARD T -DI -3, 4 FOR 6. a 'a a G\n P P 3" DIAMETER � � � � ll � � � � � � � � � ALTERNATE DESIGN. p, _ _ _ - GGLLAR • D WEEP N� W .r EE L - HOLE WITH 72"X12" ` N B. 3" DIAMETER WEEP H L SEE NOTE 8 ro 1 „ 7 MESH PLASTIC HARDWARE CLOTH x z z Z = LAS , 12" N WI GALVANIZED STEEL WIRE, MINIMUM 12"-15"-18" OR 24" n WIRE DIAMETER 0.03", NUMBER 4 MESH Tu b 53 in Q , _ i I HARDWARE CLOTH ANCHORED FIRMLY CV N iV F., P till LLII Lth TO THE OUTSIDE OF THE STRUCTURE. 9. CAST IN PLACE CONCRETE IS TO BE T a p ' P n t� CLASS A3 (3000 PSI). PRECAST • D CONCRETE IS TO BE 4000 PSI. 11/2 ' � 1 Lr 2" 10. ANY ALTERNATE METHODS OF ANCHORAGE SECTION A -A t" MEETING THE APPROVAL OF THE ENGINEER CONCRETE QUANTITIES FOR MIN. DEPTH SEE DETAIL B 77 4' MAY BE SUBSTITUTED FOR THE CAST IRON IN LUGS AS SHOWN HEREON. 12" CONCRETE PIPE - 1.440 CU, YD. CONCRETE CAST I APPROXIMATE WEIGHT 18" CONCRETE PIPE - 1.620 CU. YD. CONCRETE 11/4 Fes' -+� �4 GRATE 63 IRO B LBS 11 LETTERING IS WASTE ON ALL WATERWAY 24" CONCRETE PIPE - 1,817 CU, YD, CONCRETE 1'�' `i GRATES. LOCATION OF LETTERING MAY SECTION C -C SECTION D -D VARY BY MANUFACTURER. ADD ADDITIONAL FOOTDOFED£PTH. GRATE DETAIL tvDr STANDARD DROP INLET SPECIFICATION REFERENCE R ROAD AND BRIDGE STANDARDS SHEET 1 OF 1 REVISION DATE 12" - 2411 PIPE: MAXIMUM DEPTH (H) - 10' 233 104.01 VIRGINIA DEPARTMENT OF TRANSPORTATION 302 SEWER SERVICE LATERAL CONNECTION NOTES: 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED , THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE. 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% 1 4 PER FOOT ) 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER DIAMETER OF 4". 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. f II ►� � SALT TREATED FINISHED GROUND 2 x 4 MARKER 'L SEWER SERVICE LATERAL. CONNECTION N.T.S, FIG. S-2 NOTES, 1, THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2, CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST. 3. CURB HAVING A RADIUS OF 300 FEET OR LESS (ALONG FACE OF CURB) WILL BE PAID FOR AS RADIAL CURB. 4, THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" (15" DEPTH) OR INCREASED AS MUCH AS 3" (21" DEPTH) IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE, THE DEPTH IS TO BE 18" AS SHOWN. NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE IN DEPTH. 5 CG -2 IS TO BE USED ON ROADWAYS MEETING THE REQUIREMENTS FOR CG -6 AS SHOWN IN APPENDIX A OF THE VDOT ROAD DESIGN MANUAL, IN THE SECTION ON GS URBAN STANDARDS. �2" RADIUS a' D>a m h 4 • z '.b. SURFACE .PA, -A 00 A,. ' .4 DA' BASE ' • DPp • D.pAD. D D SUBBASE s" 411 �2" R rI/A, it I 1< 0 z w wD,p . D,e D V) 0, ,p, P.,,D 1� D DpppD.bpD DppPD�' �D 6" io SURFACE BASE SUBBASE CG -2 ACCEPTABLE ALTERNATIVE IF CURB IS EXTRUDED SPECIFICATION SP VDOT REFERENCE STANDARD 611 CURB ROAD AND BRIDGE STANDARDS 105 REVISIONDATE SHEET 1 OF 1 502 VIRGINIA DEPARTMENT OF TRANSPORTATION 201.01 EXiST GRADE METAL INSPECTION FRAME W/ SOLID LID (NEENAH R-1975 OR EQUIVALENT) 3 CONCRETE COLLAR CRUSHED STONE BEDDING 6" DI CLEANOUT PLUG AT END OF LiNE CLEANOUT DETAIL No Scale Ln I= 2. THE "H" DIMENSION SHOWN ON THE CAST I GALV. STANDARDS AND SPECIFIED ON THE PLANS IRON STEEL WILL BE MEASURED FROM THE INVERT OF 66 ± THE OUTFALL PIPE TO THE TOP OF THE 43.6 LBS ARE UCTURE. PLAN HFORMESTIMATINGG 3 LBS 1 APPROXMATE ONLY INCLUDING INCLUDING LUGS ICONNECTORS PURPOSES AND THE ACTUAL DIMENSIONS 4'-2" 112' x 1V' x 4' I %2' x 4" STRUCTURE. PLAN LUGS 12" 9�z' CSIUD SHEAR ONNECTORS 4• IN THE EVENT THE INVERT OF THE THE (GRATE REMOVED) BOTTOMS OF THE STRUCTURPIPE IS HIGHER E THE INVERT SEE DETAIL A -B>-� • -� OF THE STRUCTURE SHALL BE SHAPED WITH CEMENT MORTAR TO PREVENT SECTION B -B STANDING OR PONDING OF WATER IN THE N L!, STRUCTURE. THE COST OF FURNISHING /" AND PLACING ALL MATERIALS INCIDENTAL COLLAR DETAIL MIN RAISED UTTERING TO INLET SHAPING IS TO BE INCLUDED IN THE 810 PRICE FOR THE STRUCTURE. TO DIMENSIONS FOR DUMP NO WASTE DRAINS TO WATERWAYS 5. STEPS ARE GREBE FOR DETAILS SEE BE PROVIDED WHEN H IS G CAST IRON ONLY STANDARDST1 DETAIN•' B 6. THIS ITEM MAY BE PRECAST OR CAST - IN -PLACE. DETAIL A2'-6" 7. #4 X 8" SMOOTH DOWELS AT 4'-2" HARDWARE P_3+. SEE DETAIL B APPROXIMATELY 12" C -C TO BE 2'-7" CLOTH PLACED IN ALL AREAS ADJACENT /,r#8 4" DEPTH AGGR. i TO ABUTTING CONCRETE TO PREVENT #68, #78 ORniySETTLEMENT. 1N LIEU OF DOWELS w w ww 4.p, x 6" WIDTH \ A 2"X4" NOTCH MAY BE PROVIDED, (L 0. a (L _ !j SEE STANDARD T -DI -3, 4 FOR 6. a 'a a G\n P P 3" DIAMETER � � � � ll � � � � � � � � � ALTERNATE DESIGN. p, _ _ _ - GGLLAR • D WEEP N� W .r EE L - HOLE WITH 72"X12" ` N B. 3" DIAMETER WEEP H L SEE NOTE 8 ro 1 „ 7 MESH PLASTIC HARDWARE CLOTH x z z Z = LAS , 12" N WI GALVANIZED STEEL WIRE, MINIMUM 12"-15"-18" OR 24" n WIRE DIAMETER 0.03", NUMBER 4 MESH Tu b 53 in Q , _ i I HARDWARE CLOTH ANCHORED FIRMLY CV N iV F., P till LLII Lth TO THE OUTSIDE OF THE STRUCTURE. 9. CAST IN PLACE CONCRETE IS TO BE T a p ' P n t� CLASS A3 (3000 PSI). PRECAST • D CONCRETE IS TO BE 4000 PSI. 11/2 ' � 1 Lr 2" 10. ANY ALTERNATE METHODS OF ANCHORAGE SECTION A -A t" MEETING THE APPROVAL OF THE ENGINEER CONCRETE QUANTITIES FOR MIN. DEPTH SEE DETAIL B 77 4' MAY BE SUBSTITUTED FOR THE CAST IRON IN LUGS AS SHOWN HEREON. 12" CONCRETE PIPE - 1.440 CU, YD. CONCRETE CAST I APPROXIMATE WEIGHT 18" CONCRETE PIPE - 1.620 CU. YD. CONCRETE 11/4 Fes' -+� �4 GRATE 63 IRO B LBS 11 LETTERING IS WASTE ON ALL WATERWAY 24" CONCRETE PIPE - 1,817 CU, YD, CONCRETE 1'�' `i GRATES. LOCATION OF LETTERING MAY SECTION C -C SECTION D -D VARY BY MANUFACTURER. ADD ADDITIONAL FOOTDOFED£PTH. GRATE DETAIL tvDr STANDARD DROP INLET SPECIFICATION REFERENCE R ROAD AND BRIDGE STANDARDS SHEET 1 OF 1 REVISION DATE 12" - 2411 PIPE: MAXIMUM DEPTH (H) - 10' 233 104.01 VIRGINIA DEPARTMENT OF TRANSPORTATION 302 SEWER SERVICE LATERAL CONNECTION NOTES: 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED , THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE. 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% 1 4 PER FOOT ) 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER DIAMETER OF 4". 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. f II ►� � SALT TREATED FINISHED GROUND 2 x 4 MARKER 'L SEWER SERVICE LATERAL. CONNECTION N.T.S, FIG. S-2 NOTES, 1, THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2, CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST. 3. CURB HAVING A RADIUS OF 300 FEET OR LESS (ALONG FACE OF CURB) WILL BE PAID FOR AS RADIAL CURB. 4, THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" (15" DEPTH) OR INCREASED AS MUCH AS 3" (21" DEPTH) IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE, THE DEPTH IS TO BE 18" AS SHOWN. NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE IN DEPTH. 5 CG -2 IS TO BE USED ON ROADWAYS MEETING THE REQUIREMENTS FOR CG -6 AS SHOWN IN APPENDIX A OF THE VDOT ROAD DESIGN MANUAL, IN THE SECTION ON GS URBAN STANDARDS. �2" RADIUS a' D>a m h 4 • z '.b. SURFACE .PA, -A 00 A,. ' .4 DA' BASE ' • DPp • D.pAD. D D SUBBASE s" 411 �2" R rI/A, it I 1< 0 z w wD,p . D,e D V) 0, ,p, P.,,D 1� D DpppD.bpD DppPD�' �D 6" io SURFACE BASE SUBBASE CG -2 ACCEPTABLE ALTERNATIVE IF CURB IS EXTRUDED SPECIFICATION SP VDOT REFERENCE STANDARD 611 CURB ROAD AND BRIDGE STANDARDS 105 REVISIONDATE SHEET 1 OF 1 502 VIRGINIA DEPARTMENT OF TRANSPORTATION 201.01 EXiST GRADE METAL INSPECTION FRAME W/ SOLID LID (NEENAH R-1975 OR EQUIVALENT) 3 CONCRETE COLLAR CRUSHED STONE BEDDING 6" DI CLEANOUT PLUG AT END OF LiNE CLEANOUT DETAIL No Scale Ln I= 2. THE "H" DIMENSION SHOWN ON THE J STANDARDS AND SPECIFIED ON THE PLANS H WILL BE MEASURED FROM THE INVERT OF ONE WELDED THE OUTFALL PIPE TO THE TOP OF THE JOINT ARE UCTURE. PLAN HFORMESTIMATINGG O APPROXMATE ONLY WELD ALL PURPOSES AND THE ACTUAL DIMENSIONS CONNECTORS SHALL BE DETERMINED BY THE TO COLLAR CONTRACTOR FROM FIELD CONDITIONS. 3. WHEN SPECIFIED ON THE PLANS THE DESIGNED BY INVERT IS TO BE SHAPED IN ACCORDANCE WITH STANDARD IS -t. THE COST OF FURNISHING AND PLACING ALL MATERIALS CHECKED BY NCIDENTAL TO THE SHAPING IS TO BE 5= iNCLUDED IN THE BID PRICE FOR THE 4'-2" 112' x 1V' x 4' I %2' x 4" STRUCTURE. PLAN LUGS 12" 9�z' CSIUD SHEAR ONNECTORS 4• IN THE EVENT THE INVERT OF THE THE (GRATE REMOVED) BOTTOMS OF THE STRUCTURPIPE IS HIGHER E THE INVERT SEE DETAIL A -B>-� • -� OF THE STRUCTURE SHALL BE SHAPED WITH CEMENT MORTAR TO PREVENT SECTION B -B STANDING OR PONDING OF WATER IN THE N L!, STRUCTURE. THE COST OF FURNISHING /" AND PLACING ALL MATERIALS INCIDENTAL COLLAR DETAIL MIN RAISED UTTERING TO INLET SHAPING IS TO BE INCLUDED IN THE 810 PRICE FOR THE STRUCTURE. TO DIMENSIONS FOR DUMP NO WASTE DRAINS TO WATERWAYS 5. STEPS ARE GREBE FOR DETAILS SEE BE PROVIDED WHEN H IS G CAST IRON ONLY STANDARDST1 DETAIN•' B 6. THIS ITEM MAY BE PRECAST OR CAST - IN -PLACE. DETAIL A2'-6" 7. #4 X 8" SMOOTH DOWELS AT 4'-2" HARDWARE P_3+. SEE DETAIL B APPROXIMATELY 12" C -C TO BE 2'-7" CLOTH PLACED IN ALL AREAS ADJACENT /,r#8 4" DEPTH AGGR. i TO ABUTTING CONCRETE TO PREVENT #68, #78 ORniySETTLEMENT. 1N LIEU OF DOWELS w w ww 4.p, x 6" WIDTH \ A 2"X4" NOTCH MAY BE PROVIDED, (L 0. a (L _ !j SEE STANDARD T -DI -3, 4 FOR 6. a 'a a G\n P P 3" DIAMETER � � � � ll � � � � � � � � � ALTERNATE DESIGN. p, _ _ _ - GGLLAR • D WEEP N� W .r EE L - HOLE WITH 72"X12" ` N B. 3" DIAMETER WEEP H L SEE NOTE 8 ro 1 „ 7 MESH PLASTIC HARDWARE CLOTH x z z Z = LAS , 12" N WI GALVANIZED STEEL WIRE, MINIMUM 12"-15"-18" OR 24" n WIRE DIAMETER 0.03", NUMBER 4 MESH Tu b 53 in Q , _ i I HARDWARE CLOTH ANCHORED FIRMLY CV N iV F., P till LLII Lth TO THE OUTSIDE OF THE STRUCTURE. 9. CAST IN PLACE CONCRETE IS TO BE T a p ' P n t� CLASS A3 (3000 PSI). PRECAST • D CONCRETE IS TO BE 4000 PSI. 11/2 ' � 1 Lr 2" 10. ANY ALTERNATE METHODS OF ANCHORAGE SECTION A -A t" MEETING THE APPROVAL OF THE ENGINEER CONCRETE QUANTITIES FOR MIN. DEPTH SEE DETAIL B 77 4' MAY BE SUBSTITUTED FOR THE CAST IRON IN LUGS AS SHOWN HEREON. 12" CONCRETE PIPE - 1.440 CU, YD. CONCRETE CAST I APPROXIMATE WEIGHT 18" CONCRETE PIPE - 1.620 CU. YD. CONCRETE 11/4 Fes' -+� �4 GRATE 63 IRO B LBS 11 LETTERING IS WASTE ON ALL WATERWAY 24" CONCRETE PIPE - 1,817 CU, YD, CONCRETE 1'�' `i GRATES. LOCATION OF LETTERING MAY SECTION C -C SECTION D -D VARY BY MANUFACTURER. ADD ADDITIONAL FOOTDOFED£PTH. GRATE DETAIL tvDr STANDARD DROP INLET SPECIFICATION REFERENCE R ROAD AND BRIDGE STANDARDS SHEET 1 OF 1 REVISION DATE 12" - 2411 PIPE: MAXIMUM DEPTH (H) - 10' 233 104.01 VIRGINIA DEPARTMENT OF TRANSPORTATION 302 SEWER SERVICE LATERAL CONNECTION NOTES: 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED , THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE. 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% 1 4 PER FOOT ) 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER DIAMETER OF 4". 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. f II ►� � SALT TREATED FINISHED GROUND 2 x 4 MARKER 'L SEWER SERVICE LATERAL. CONNECTION N.T.S, FIG. S-2 NOTES, 1, THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2, CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST. 3. CURB HAVING A RADIUS OF 300 FEET OR LESS (ALONG FACE OF CURB) WILL BE PAID FOR AS RADIAL CURB. 4, THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" (15" DEPTH) OR INCREASED AS MUCH AS 3" (21" DEPTH) IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE, THE DEPTH IS TO BE 18" AS SHOWN. NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE IN DEPTH. 5 CG -2 IS TO BE USED ON ROADWAYS MEETING THE REQUIREMENTS FOR CG -6 AS SHOWN IN APPENDIX A OF THE VDOT ROAD DESIGN MANUAL, IN THE SECTION ON GS URBAN STANDARDS. �2" RADIUS a' D>a m h 4 • z '.b. SURFACE .PA, -A 00 A,. ' .4 DA' BASE ' • DPp • D.pAD. D D SUBBASE s" 411 �2" R rI/A, it I 1< 0 z w wD,p . D,e D V) 0, ,p, P.,,D 1� D DpppD.bpD DppPD�' �D 6" io SURFACE BASE SUBBASE CG -2 ACCEPTABLE ALTERNATIVE IF CURB IS EXTRUDED SPECIFICATION SP VDOT REFERENCE STANDARD 611 CURB ROAD AND BRIDGE STANDARDS 105 REVISIONDATE SHEET 1 OF 1 502 VIRGINIA DEPARTMENT OF TRANSPORTATION 201.01 EXiST GRADE METAL INSPECTION FRAME W/ SOLID LID (NEENAH R-1975 OR EQUIVALENT) 3 CONCRETE COLLAR CRUSHED STONE BEDDING 6" DI CLEANOUT PLUG AT END OF LiNE CLEANOUT DETAIL No Scale Ln I= in J H rN r14 O 12/14/2018 O DRAWN BY A. FONTAINE DESIGNED BY c( O Q CHECKED BY 5= C. SHIFFLETT Q SCALE Zi LU � 3 a Q Lu Lll � _v iJ. QoQ z 0- o o O q Ce I- CU Lf] �+ a ®CL o Go ~ 0 �x < LL1 LL 10 0 C:) w dLn 1-- CU CD Cf) CU CD Lu m® U rI C aF- 0 U oll- Z:) O Q W _ ti (D LII Lu Lu Q 0 M z O 01- 75 N > N U uiN N 0 C6 Lu 71 N 0 Q 0 N N N o O i m t C m ^G U 0 _- (,,,) 0 uj QUJ 0- a) Ll! O V 2(D Q UJ < °' z N 0 C) � C) - C T ~ o P u Cu r N (4 w PI 1 C 0- U O C Z N O m --.; Q � X m o 0 3 0 0- O '§ 0- v� N UC) C) a) C). - a) a) w `a0 U) U C O N t= � O U � O ) C (6 Q U JOB NO. 0 o U .- (E V 42231 � O � U SHEET jNO. Q o CI.D 1 in DATE H eD 12/14/2018 O DRAWN BY A. FONTAINE DESIGNED BY A. FONTAINE CHECKED BY C. SHIFFLETT SCALE 1 "=30' 01- 75 N > N U uiN N 0 C6 Lu 71 N 0 Q 0 N N N o O i m t C m ^G U 0 _- (,,,) 0 uj QUJ 0- a) Ll! O V 2(D Q UJ < °' z N 0 C) � C) - C T ~ o P u Cu r N (4 w PI 1 C 0- U O C Z N O m --.; Q � X m o 0 3 0 0- O '§ 0- v� N UC) C) a) C). - a) a) w `a0 U) U C O N t= � O U � O ) C (6 Q U JOB NO. 0 o U .- (E V 42231 � O � U SHEET jNO. Q o CI.D 1 i 112 1 1 TC 469.56 Qv WQ N TC 466.19 — SCALE 1"=20' 0 20' 40' Uj DATE H - � U 422.1 12/14/2018 0 Ln DRAWN BY SHEET NO. A. FONTAINE DESIGNED BY � u A. FONTAINE o CHECKED BY C. SHIFFLETT M CK > E LU E Q- �LU ce LU�—o �. LL a 0oU.1 o O Q LU M Q E- 0 Ln a �00 ti �� f O 0 3: U' o v� oCD CD ®cu W L Ul > 7® LU (3 m ® U �0 C=)LU j F O U W ZD 0 ti Q 5� W 0 ct I-- LU w w Q ® M 0 Uj DATE H - � U 422.1 12/14/2018 0 DRAWN BY SHEET NO. A. FONTAINE DESIGNED BY A. FONTAINE CHECKED BY C. SHIFFLETT SCALE 1 "=20' N JOB NO. N o (n - � U 422.1 c N C N O � U SHEET NO. Q o y. ......... . .......... z . - ... 1, AREAa - AUTOZONE 9 6,816 SF SCALE 1"=20' 0 20' 40' uj U C j N N O t6 i� N N O Q c O_ T C ujO N N 7 N 4 O O > zw S ol < N `r} M C 0 <u L _� LIJ .0 m 2-0 �z z wo 2 5i o:2i �o =) U O Z N O N Q X N HN O iz O Q O O_ m N C Y N � 7 N U X r N O cz N U N N O N U O O N E O O U (6 O ® � O U JOB NO. 0 o N ._ � U 4223.E %co n n 0 � O U SHEET NO. `-0° o C1.L F DATE Ln 12/14/2018 O N® o A. FONTAINE DESIGNED BY A. FONTAINE CHECKED BY 00 C. SHIFFLETT SCALE >E — W � C a Q E �LUU� Q U.C) z J WU®C; o Q Ln ~ � z�U)CD 0 mx w O a �� o U� z '�1 S L lD CD > r'4 UO m0 ® LU _10 ow '� O c 4 � 0 Q LQ C7 W W0 0 LU d c M Q Z O uj U C j N N O t6 i� N N O Q c O_ T C ujO N N 7 N 4 O O > zw S ol < N `r} M C 0 <u L _� LIJ .0 m 2-0 �z z wo 2 5i o:2i �o =) U O Z N O N Q X N HN O iz O Q O O_ m N C Y N � 7 N U X r N O cz N U N N O N U O O N E O O U (6 O ® � O U JOB NO. 0 o N ._ � U 4223.E %co n n 0 � O U SHEET NO. `-0° o C1.L F DATE 12/14/2018 O DRAWN BY A. FONTAINE DESIGNED BY A. FONTAINE CHECKED BY 00 C. SHIFFLETT SCALE 1 "=20' uj U C j N N O t6 i� N N O Q c O_ T C ujO N N 7 N 4 O O > zw S ol < N `r} M C 0 <u L _� LIJ .0 m 2-0 �z z wo 2 5i o:2i �o =) U O Z N O N Q X N HN O iz O Q O O_ m N C Y N � 7 N U X r N O cz N U N N O N U O O N E O O U (6 O ® � O U JOB NO. 0 o N ._ � U 4223.E %co n n 0 � O U SHEET NO. `-0° o C1.L F PRELIMINARY WATER QUANTITY ANALYSIS POINT 1 DRAINAGE AREA ANALYSIS (PRE -DEVELOPMENT) DRAINAGE AREA ANALYSIS (POST -DEVELOPMENT 'J PRE AREA POST AREA 1-U (UNDETAINED) AREA = 1.38 ACRES AREA = 0.32 ACRES 0.87 ACRES (IMPERVIOUS) 0.10 ACRES (IMPERVIOUS) 0.51 ACRES (MANAGED TURF) 0.22 ACRES (MANAGED TURF) Tc = 6 MIN Tc = 6 MIN Q (CFS) V (AC -FT) Q (CFS) V (AC -FT) 1 YEAR 5.13 0.263 1 YEAR 0.92 0.045 2 YEAR 6.40 0.332 2 YEAR 1.22 0.060 10 YEAR 10.13 10 YEAR 2.09 POST AREA 1-D (DETAINED) AREA = 1.06 ACRES 0.97 ACRES (IMPERVIOUS) E 0.09 ACRES (MANAGED TURF) Q Tc = 6 MIN Q (GFS) V (AC -FT) 1 YEAR 4.26 0.228 2 YEAR 5.21 0.283 10 YEAR 8.02 FLOW THROUGH PIPE STORAGE Lu E FLOWS ROUTED THROUGH DETENTION SYSTEM. Q (CFS) 1 YEAR 2.90 2 YEAR 4.51 10 YEAR 7.89 COMBINED FLOW AT ANALYSIS POINT 1 Q (CFS) 1 YEAR 3.69 2 YEAR 5.61 10 YEAR 9.98 CHANNEL PROTECTION (ENERGY BALANCE): QDEVELOPED < 0.80*(QPRE-DEVELOPED*RVPRE-DEVELOPED)/RVDEVELOPED OK 3.69 CFS 5 0.80*(5.13 CFS*0.263 AC-FT)/(0.273 AC -FT) = 3.95 CFS FLOOD PROTECTION: POST -DEVELOPED Q,05 PRE -DEVELOPED Q10 OK 9.98 CFS (POST -DEVELOPED Q10) <_ 101.13 CFS (PRE -DEVELOPED Q10) WATER gUALITY ANALYSIS SITE DATA PRE DEVELOPED AREA IMPERVIOUS = 0.87 ACRES MANAGED TURF = 0.50 ACRES PRE DEVELOPMENT LOAD (TP) (LB/YR) = 2.18 POST IDEVELOPED AREA IMPERVIOUS = 1.07 ACRES (MANAGED TURF = 0.31 ACRES POST IDEVELOPMENT LOAD (TP) (LB/YR) = 2.50 MAXIMUM PERCENT REDUCTION REQUIRED FOR REDEVELOPMENT = 20% TOTAL_ LOAD REDUCTION REQUIRED (LB/YR) = 0.76 CREDITS TO BE PURCHASED c N`" NVQ 4#o Ln E DATE 'J 12/14/2018 0 rev o O A. FONTAINE DESIGNED BY N A. FONTAINE CHECKED BY C. SHIFFLETT SCALE 1 "=30" _F E Q Z Lu E Q Lu u LuL�� cl�ti o < J LULU®koO Q r a) Ln f :3o �oul00 rm< w OO �u a Ln ® W 0 �o > �N w O m o cC U -, o ow Z O U ui 0 W T � 0 LQ � h- 0 Lu w LLJ = Q Q M z 0 Vy DATE 12/14/2018 0 DRAWN BY A. FONTAINE DESIGNED BY A. FONTAINE CHECKED BY C. SHIFFLETT SCALE 1 "=30" _F 1 NOTE: PER THE GEOTECHNICAL REPORT, EXISTING ASPHALT PAVEMENT SHOULD BE REMOVED AND HAULED OFF SITE. ABANDONED BURIED UTILITIES AND UTILITY TRENCH BACKFILLS SHOULD ALSO BE REMOVED. SPECIAL ATTENTION SHOULD BE GIVEN TO REMOVE ANY REMNANTS OF THE PREVIOUS RESTAURANT BUILDING, INCLUDING FOUNDATIONS, UNDERGROUND UTILITIES, GREASE TRAP, AND /OR OTHER PREVIOUS CONSTRUCTION THAT WAS NOT REMOVED DURING THE PREVIOUS DEMOLITION ACTIVITIES. .. . r J ; r ......... »> - - ` r 3� 3�3 , ...:. ASPHALT E0T LEGEND: REMOVE CONCRETE REMOVE ASPHALT REMOVE TREE SAW CUT SCALE 1"=20' 0 20' 40' ` 45'KOLL AS NEEDED U LLL �'KLMUVE. . LIGHT. . . . . 45 H01Y SCALE 0 1 ”=20' D7.0 Q A C r,4 ® 7 o� u { � z z L.I<i1 m N � N GRASS T �(D wcn C)Od 0 > E ASPHALT q .., ;( P VEMENT . GAS ui 4-� Q E Lu v 3 RELOCATE .,, :.. ®u"pko Ui i _1 �LL (n GAS POLE GRass C d ® -I z Lu Lu O Q , : n.� -, GRASS a sraRa MH " RW=4$0.50 '. �, . ............ .......... ..... ............. ............. . ........... ,.. ....... .„ ... o ULT .. yA _ 1NV �3 5't' », oQ W , ;. r LL LL ® Yo Imo, . .� ......... ,__, __.r . , . _..... . :. w z ;n Ln t./) ............. , , au ® -0O > 5 N Lu O "i mCD _ U J J 10 C) w .............. .... .... »..,_ . ,..v,.,.. _ r' F- O :. U ui o w S � ADJUST MH TOP C.7 � „ ......... � TO PROP. GRADE w RELOCATE o � € POWER POLE r �R� 3, REMOVE z CONCRETE CURB r ' ,,.... AND GUTTER ,,,,„,,,,, ....................,,,, „ ,:. .....:..,.:......., uj m / J J , j , z 0 ......... .. ..ilii,r..iu:.::.:-.:..........::::z:::vi:.••.;-,. :. -- -.... :., r ... r LEGEND: REMOVE CONCRETE REMOVE ASPHALT REMOVE TREE SAW CUT SCALE 1"=20' 0 20' 40' vi DATE 12/14/2018 O DRAWN BY A. FONTAINE DESIGNED BY A. FONTAINE LLL CHECKED BY Ln E SCALE 0 1 ”=20' D7.0 Q A C r,4 ® 7 o� O < � z z L.I<i1 m N � N T �(D wcn C)Od 0 > E .tom. q G Q ui 4-� Q E Lu v 3 ®u"pko Ui i _1 �LL (n C d ® -I z Lu Lu O Q z®U)0 CLI oQ W LL LL ® Yo Imo, U �CD z z 0 w z ;n Ln t./) au ® -0O > 5 N Lu O "i mCD U 10 C) w r' F- O U ui o w S � C.7 � � w o � z r uj m z 0 vi DATE 12/14/2018 O DRAWN BY A. FONTAINE Lu v z > 0 g z (p . V ® O N DESIGNED BY A. FONTAINE LLL CHECKED BY C. SHIFFLETT SCALE 0 1 ”=20' D7.0 Q A C 7 o� 1 II 1 < Lu v z > 0 g z (p . V ® O N s U LLL 3 U S � 0 0 Q D7.0 Q A C Lu v z > 0 g z (p . V ® O N 1 7 0 Q � > .� Y q ai 3 N U X 0 N O � N O dL N U = O O ZO U cu O ® ) U JOB NO. W U 4223 J S � 0 d U D7.0 W0 m 7 o� 1 II 1 < � z z L.I<i1 N � T �(D wcn C)Od 0 .tom. G Q 1 7 0 Q � > .� Y q ai 3 N U X 0 N O � N O dL N U = O O ZO U cu O ® ) U JOB NO. � o U)- U 4223 C U N = � O U SHEET NO. Q o D7.0 m -o w a� oE i - 20' HT. PARKING LOT LIGHT FIXTURES s /.- INTERIOR PARKING LOT LANDSCAPED AREA a _... __ _ ... -...::::::::..:::::::::::.....::...../ PARKING LOT LANDSCAPED AREA 3,409 SF::...::..:.:.:.:...�::.::<.,::.::::�.«:::.:.::.......:..,;,.::...�::M.�� PLANT SCHEDULE TREES BOTANICAL NAME BET HER BETULA NIGRA HERITAGE' GIN PRN GINKGO BILOBA 'PRINCETON SENTRY' PLR ACE PLATANUS X ACERIFOLIA QUE BIC QUERCUS BICOLOR ULM ALL ULMUS PARVIFOLIA'ALLEE' DESIGNED BY FLOWERING TREES BOTANICAL NAME MAG SWE MAGNOLIA VIRGINIANA 00 SHRUBS BOTANICAL NAME ILE INK ILEX GLABRA'COMPACTA' ILE WIN ILEX VERTICILLATA ITA VIR ITEA VIRGINICA SHRUB AREAS BOTANICAL NAME ITE SPR ITEA VIRGINICA'SPRICH' PAN SHN PANICUM VIRGATUM 'SHENANDOAH' GROUND COVERS BOTANICAL NAME CAR SED CAREX PENSYLVANICA HYP PER HYPERICU M PERFORATUM SCALE 1"=20' 0 20' 40' ACTH OA Jl lt;sto"'. 14 MI y 3/04/19 cU DATE 12/14/2018 O Lo E DRAWN BY M. RACHNER DESIGNED BY rq ® M. RACHNER O CHECKED BY 00 F. HANCOCK N 1"=20' --T � Q > E Q z Lu c E Q W U Lu Ly ¢U. -I CD z J LU W® 6 O Q aP-v L' H,au7� a s' fu 0 3: Lu w O� o u ru O H z yr Ln H m O L W ci > O m 'D c U ,-j0 CD j O U ce Z O W (D Z:) O W cl� I-- � Q o C M Z O cU DATE 12/14/2018 O DRAWN BY M. RACHNER DESIGNED BY M. RACHNER CHECKED BY 00 F. HANCOCK SCALE 1"=20' --T ai uj U C N N O H N N O jj�\�j O_ 7i 1 ceLLJ O O O N N 7 N 4 O N t6 S Lj Q o = <U< LLN U< !LI =5O m Z CU) z Z 2:E o:E cz O �o caN d V U) S Z O Q a) o o 0 m o o � Q � Q) c Fn cu 0 N U X 0 N O U U :E i N O N U O O N E O � U O 4 U JOB NO. 0 o N — -jJ � U 422.31 I N f_- 0 O � U SHEET NO.ID g o L1.0 a HEIGHT VARIES WITH PL 12" MIN. t C E N E RAL NOTES 3- 2" x 2" HARDWOOD STAKES QTY ROOT BALL PRE -CONSTRUCTION 6" SAUCER — 12 GAUGE GALVANIZED WIRE + CONTRACTOR IS RESPONSIBLE FOR CONTACTING "MISS UTILITY" AT PERIMETER ROOTS 1.800.552.7001 FOR LOCATION OF ALL UTILITY LINES.TREES SHALL BE 2.5" CAL. LOCATED A MINIMUM OF 5 FEET FROM SEWER/WATER CONNECTIONS. GIN PRN NOTIFY LANDSCAPE ARCHITECT OF CONFLICTS. GINKGO BILOBA 'PRINCETON SENTRY' • VERIFY ALL PLANT MATERIAL QUANTITIES ON THE PLAN PRIOR TO 3.5" CAL. BIDDING, PLANT LIST TOTALS ARE FOR CONVENIENCE ONLY AND SHALL PLA ACE BE VERIFIED PRIOR TO BIDDING. PLATANUS X ACERIFOLIA • PROVIDE PLANT MATERIALS OF QUANTITY, SIZE, GENUS, SPECIES, AND NEW 1/2" RUB VARIETY INDICATED ON PLANS. ALL PLANT MATERIALS AND QUE BIC INSTALLATION SHALL COMPLY WITH RECOMMENDATIONS SAND 12 GAUGE GALVAN REQUIREMENTS OF ANSI Z60.1 "AMERICAN STANDARD FOR NURSERY ALLOW FOR SLIGHT N STOCK". IF SPECIFIED PLANT MATERIAL IS NOT OBTAINABLE, SUBMIT 3 2x2 HARDWOO PROOF OF NON AVAILABILITY TO THE LANDSCAPE ARCHITECT, 2'-6" MIN BELOW TOGETHER WITH PROPOSAL FOR USE OF EQUIVALENT MATERIAL. STAKE SHALL BE • PROVIDE AND INSTALL ALL PLANTS AS IN ACCORDANCE WITH DETAILS MIN. 18" OUT FR1 AND CONTRACT SPECIFICATIONS. AND OUTSIDE OF • SOIL TESTS SHALL BE PERFORMED TO DETERMINE SOIL CHARACTER COMMON NAME AND QUALITY. NECESSARY SOIL AMENDMENTS SHALL BE PERFORMED SET ROOTBALL FLUSH TO PER TEST RESULTS TO ENSURE PLANT HEALTH. 1-2" HIGHER IN SLOWLY MAGNOLIA VIRGINIANA SOILS. DO NOT COVER TI CONSTRUCTION/INSTALLATION THE ROOTBALL' ROOTFLARE SHALL'. • LANDSCAPE ARCHITECT RESERVES THE RIGHT TO REJECT ANY PLANTS ABOVE FINISH AND MATERIALS THAT ARE IN AN UNHEALTHY OR UNSIGHTLY MIN. INSTALLED SIZE CONDITION, AS WELL AS PLANTS AND MATERIALS THAT DO NOT PRUNE CONFORM TO ANSI Z60.1 "AMERICAN STANDARD FOR NURSERY STOCK" ILEX GLABRA "COMPACTA' + LABEL AT LEAST ONE TREE AND ONE SHRUB OF EACH VARIETY AND 18"-24" HTJSPRD. CALIPER WITH A SECURELY ATTACHED, WATERPROOF TAG BEARING ILE WIN THE DESIGNATION OF BOTANICAL AND COMMON NAME. ILEX VERTICILLATA + INSTALL LANDSCAPE PLANTINGS AT ENTRANCES/EXITS AND PARKING 18"-24" HT./SPRD. AREAS ACCORDING TO PLANS SO THAT MATERIALS WILL NOT 1:1 SLOPE OP INTERFERE WITH SIGHT DISTANCES. PLAN • CONTRACTOR IS RESPONSIBLE FOR WATERING ALL PLANT MATERIAL SCARIFY SIDES BEFORE DURING INSTALLATION AND UNTIL FINAL INSPECTION AND ACCEPTANCE BY OWNER. CONTRACTOR SHALL NOTIFY OWNER OF CONDITIONS PLACE ROt WHICH AFFECTS THE GUARANTEE. UNEXCAVATED OR TA INSPECTIONS/GUARANTEE SPACING • UPON COMPLETION OF LANDSCAPE INSTALLATION, THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR WHO WILL VERIFY COMPLETENESS, INCLUDING THE REPLACEMENT OF ALL DEAD PLANT MATERIAL. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING A FINAL INSPECTION BY THE LANDSCAPE ARCHITECT. • ALL EXTERIOR PLANT MATERIALS SHALL BE GUARANTEED FOR ONE FULL YEAR AFTER DATE OF FINAL INSPECTION AGAINST DEFECTS INCLUDING DEATH AND UNSATISFACTORY GROWTH. DEFECTS RESULTING FROM NEGLECT BY THE OWNER, ABUSE OR DAMAGE BY OTHERS, OR UNUSUAL PHENOMENA OR INCIDENTS WHICH ARE BEYOND THE CONTRACTORS CONTROL ARE NOT THE RESPONSIBILITY OF THE CONTRACTOR. • PLANT MATERIAL QUANTITIES AND SIZES WILL BE INSPECTED FOR COMPLIANCE WITH APPROVED PLANS BY A SITE PLAN REVIEW AGENT OF THE PLANNING DEPARTMENT PRIOR TO THE RELEASE OF THE CERTIFICATE OF OCCUPANCY. • REMOVE ALL GUY WIRES AND STAKES 12 MONTHS AFTER INSTALLATION. EDGE OF BUILDING, WALK OR STRUCTURE VOIDS MULCH LINE PLANT UNDER DRIP LINE OF LIMBED UP SHRUBS & TREES TRIANGULAR INFILL SPACING PLANT PERIMETER AT INDICATED SPACING PLANT UP TO EDGE OF SHRUBS UNLESS OTHERWISE NOTED PLANT 2-3" MULCH LAYER 1" COMPOST LAYER AMENDED SOIL MIX UNDISTURBED EARTH GROUNDCOVER/ PERENNIAL PLANTING NOT TO SCALE s MULTI -STEM TREE - STAKING SPECIFIED NOT TO SCALE PRUNE CODOMINATE LEADERS REMOVE BROKEN, BADLY DEFORMED, RUBBING, NARROW CROTCH ANGLES, WATER SPROUTS, OR CROSS -BRANCHES. REMOVE TAGS, LABELS, AND PLASTIC SLEEVING. DO NOT STAKE UNLESS SPECIFIED (SEE NOTE) DO NOT WRAP TRUNK PRUNE SUCKERS IF FIELD GROWN, CUT AWAY ALL BALLING ROPES. REMOVE BURLAP OR WIRE BASKET FROM TOP 3 OF BALL. IF CONTAINER GROWN, REMOVE CONTAINER AND CUT CIRCLING ROOTS 1:1 SLOPE OF SIDES OF PLANTING HOLE SCARIFY SIDES BEFORE PLANTING TAMP SOIL AROUND ROOTBALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOTBALL DOES NOT SHIFT DO NOT PRUNE TERMINAL LEADER OR BRANCH TIPS REMOVE TAGS, LABELS AND PLASTIC SLEEVING DO NOT WRAP TRUNK PRUNE BROKEN BRANCHES 2-3" MULCH LAYER TO EDGE OF DRIPLINE. KEEP 4-6" AWAY FROM TRUNK FLARE BACKFILL PLANTING PIT WITH NATIVE SOIL. INCORPORATE SLOW-RELEASE GRANULAR FERTILIZER 6" SAUCER 1" COMPOST LAYER IF FIELD GROWN CUTAWAY ALL BALLING ROPES. REMOVE BURLAP OR WIRE BASKET FROM TOP 3 OF BALL. IF CONTAINER GROWN, REMOVE CONTAINER AND CUT CIRCLING ROOTS TAMP SOIL AROUND ROOTBALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOTBALL DOES NOT SHIFT DECIDUOUS TREE - STAKING SPECIFIED NOT TO SCALE INSTALL SHRUBS SO THAT THE TOP OF THE ROOTBALL IS AT THE SAME GRADE AS ORIGINALLY GROWN OR 1-2" ABOVE IN POOR DRAINING SOILS. DO NOT COVER THE TOP OF THE ROOTBALL WITH SOIL REMOVE ALL STRING, WIRE, AND BURLAP FROM TOP 3 OF BALL BACKFILL PLANTING PIT WITH NATIVE SOIL. INCORPORATE SLOW-RELEASE GRANULAR FERTILIZER SCARIFY BOTTOM AND SIDES OF PIT SHRUB PLANTING NOT TO SCALE CONTAINER :w ROOT BALL 12 GAUGE GALVANIZED WIRE 3-2"x2" HARDWOOD STAKES GALVANIZED WIRE GUY 12 GAUGE. ALLOW FOR A SLIGHT AMOUNT OF MOVEMENT 8'2"x2" HARDWOOD STAKE, 2'-6" MIN BELOW SURFACE. STAKE SHALL BE DRIVEN A MIN 18" OUT FROM TRUNK AND OUTSIDE OF ROOTBALL 2-3" MULCH LAYER TO EDGE OF DRIPLINE. KEEP 4-6" AWAY FROM TRUNKFLARE SET ROOTBALL FLUSH TO GRADE OR 1-2" HIGHER IN SLOWLY DRAINING SOILS. DO NOT COVER THE TOP OF THE ROOTBALL WITH SOIL. ROOTFLARE SHALL BE VISIBLE ABOVE FINISHED GRADE 6" SAUCER BACKFILL PLANTING PIT WITH NATIVE SOIL. INCORPORATE SLOW-RELEASE GRANULAR FERTILIZER 1" COMPOST LAYER PLACE ROOTBALL ON UNEXCAVATED OR TAMPED SOIL NOTE: ONLY STAKE TREES WITH LARGE CROWNS, 2" CALIPER OR GREATER, IF LOCATED ON WINDY SITES, OR WHERE TAMPERING MAY OCCUR. REMOVE ALL DEAD, BROKEN, DISEASED, AND WEAK BRANCHES AT TIME OF PLANTING 2-3" MULCH LAYER, KEEP AWAY FROM TRUNK 1" COMPOST LAYER PLANT SCHEDULE PROVIDE MULCH UP AND OVER QTY SAUCER COMMON NAME 6" SAUCER — REMOVE CONTAINER. SCARIFY 2 PERIMETER ROOTS PLANT SCHEDULE TREES QTY BOTANICAL NAME COMMON NAME MIN. INSTALLED SIZE CANOPY SF BET HER 2 BETULA NIGRA'HERITAGE' HERITAGE RIVER BIRCH 2.5" CAL. 397 GIN PRN 9 GINKGO BILOBA 'PRINCETON SENTRY' PRINCETON SENTRY GINKGO 3.5" CAL. 397 PLA ACE 6 PLATANUS X ACERIFOLIA LONDON PLANE TREE 2.5" CAL. 175 QUE BIC 3 QUERCUS BICOLOR SWAMP WHITE OAK 2.5" CAL. 368 ULM ALL 6 ULMUS PARVIIFOLIA'ALLEE' ALLEE LACEBARK ELM 2.5" CAL. 299 FLOWERING TREES QTY BOTANICAL NAME COMMON NAME MIN. INSTALLED SIZE CANOPY SF MAG SWE 12 MAGNOLIA VIRGINIANA SWEET BAY 2" CAL. 100 SHRUBS QTY BOTANICAL NAME COMMON NAME MIN. INSTALLED SIZE ¢ LU ILE INK 45 ILEX GLABRA "COMPACTA' COMPACT INKBERRY 18"-24" HTJSPRD. ILE WIN 42 ILEX VERTICILLATA WINTERBERRY 18"-24" HT./SPRD. ITA VIR 66 ITEA VIRGINICA VIRGINIA WILLOW 18"-24" HT./SPRD. SHRUB AREAS QTY BOTANICAL NAME COMMON NAME MIN. INSTALLED SIZE SPACING ITE SPR 51 ITEA VIRGINICA'SPRICH' VIRGINIA SWEETSPIRE 18" SPRD. 30" o.c. PAN SHN 45 PANICUM VIRGATUM 'SHENANDOAH' SWITCH GRASS 18" SPRD. 30" o.c. GROUND COVERS QTY BOTANICAL NAME COMMON NAME MIN. INSTALLED SIZE SPACING CAR SED 217 CAREX PENSYLVANICA PENNSYLVANIA SEDGE 1 GAL. 18" o.c. HYP PER 40 HYPERICUM PERFORATUM ST. JOHNS WORT 1 GAL. 18" ox. STREET TREE REQUIREMENTS * per Sec. 32.7.9.5 of the Albermarle County Code STREET LENGTH REQUIREMENTS CALCULATIONS REQUIRED PROVIDED SEMINOLE TRAIL 301.5 LF 1 LG TREE PER 35 LF 301.5/35 = 8.6 9 LG TREES 9 LG TREES WESTFIELD ROAD 232.64 LF 1 LG TREE PER 40 LF 232.64/40 = 5.8 6 LG TREES 6 LG TREES INTERIOR PARKING LOT LANDSCAPE AREA REQUIREMENTS * per Sec. 32.7.9.6 of the Albemarle County Code REQUIREMENT PARKING LOT AREA CALCULATIONS REQUIRED PROVIDED 5% GROSS PARKING AREA 28,639.13 SF 28,639.13 x.05 = 1,431.96 SF 1,432 SF 3,409 SF INTERIOR PARKING LOT LANDSCAPING REQUIREMENTS * per Sec. 32.7.9.6 of the Albemarle County Code REQUIREMENT PARKING LOT SPACES CALCULATIONS REQUIRED PROVIDED 1 LG. OR 1 MED. SHADE PROVIDED QUANTITY 1.42 AC (GROSS SITE O 10% COVER TREE PER 10 PARKING 55 PARKING SPACES 55/10 = 5.5 6 LG. OR MED. SHADE TREES 11 LARGE SHADE TREES SPACES = 6,185.52 SF DESIGNED BY TREE COVER CALCULATIONS * per Sec. 32.7.9.8 of the Albemarle County Code SITE AREA REQUIREMENT CALCULATION REQUIRED QUANTITY PROVIDED QUANTITY 1.42 AC (GROSS SITE O 10% COVER 1.42 AC x. 1 = 0.142 AC 6,186 SF 10,040 SF AREA) 4 M. RACHNER = 6,185.52 SF DESIGNED BY NOTE: -WHERE A PARKING AREA IS LOCATED SO THAT PARKED CARS ARE VISIBLE FROM AN OFF-SITE STREET, SHRUBS ARE TO BE INSTALLED AT A MINIMUM HEIGHT OF 12". -ALL SIRE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND BE MAINTAINED AT, MATURE HEIGHT; THE TOPPING OF TREES IS PROHIBITED. SHRUBS AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. NLTH OF 57 'ANK W.HA III W.14W 3/04/19 , PE A� Ln E [n DATE rh1v ® 12/14/2018 O O N 4 M. RACHNER DESIGNED BY Q CHECKED BY > E F. HANCOCK SCALE NTS s LU E 0. ¢ LU U, Ld LLC:) a0 o n 0 J Q arQ) Ln z0��' O ao ¢ w a Ln o O W U)%D 5o S O ui mQ U _j 00 aw O U W Ln O U'll V) UJ o r o w LU U ® M z O v .N LUU v o N O a T C CU LU D LLJ < Q o s 06 >� s z LU 2 p LUo LU v J Z � 70 D_ C)o ED o� Uj Q 2z (I)o U) 2:�i 0 0 0 z �� �N N < a o U j 0 O z N :5 Q 4 x Q) ow O Q �0 Q o -� > U N U .O O U � N 0 o �Q v E U O � U JOB NO. 0 o CU U 42231 N s O U SHEET NO. 00 v � L2.0 F [n DATE M 12/14/2018 O DRAWN BY M. RACHNER DESIGNED BY M. RACHNER CHECKED BY F. HANCOCK SCALE NTS s v .N LUU v o N O a T C CU LU D LLJ < Q o s 06 >� s z LU 2 p LUo LU v J Z � 70 D_ C)o ED o� Uj Q 2z (I)o U) 2:�i 0 0 0 z �� �N N < a o U j 0 O z N :5 Q 4 x Q) ow O Q �0 Q o -� > U N U .O O U � N 0 o �Q v E U O � U JOB NO. 0 o CU U 42231 N s O U SHEET NO. 00 v � L2.0 F