HomeMy WebLinkAboutARB201900017 Staff Report 2019-03-29ARCHITECTURAL REVIEW BOARD STAFF REPORT
Project #/Name
ARB-2019-17: Pantops Corner Self Storage
Review Type
Initial Site Development Plan and conceptual architectural review
Parcel Identification
078000000005EO
Location
1321 Stony Point Road
Zoned
Highway Commercial (HC)/Entrance Corridor (EC)
Owner/Applicant
Pantops LC/Shimp Engineering (Justin Shimp)
Magisterial District
Rivanna
Proposal
To construct a self -storage building with associated site improvements.
Context
The site is located in the Pantops commercial area, at the intersection of Rts. 20 and 250 adjacent to other parcels that
are under review or expected to redevelop in the near future.
Visibility
This building is expected to be visible from the Rt. 20 and 250 Entrance Corridors, rising above the Flow and
Goodwill buildings.
ARB Meeting Date
April 1, 2019
Staff Contact
Margaret Maliszewski
PROJECT HISTORY
The site of this proposal is currently vacant. The ARB has reviewed, and will review in the near future, multiple proposals for development surrounding
this site.
REF
GUIDELINE
ISSUE
RECOMMENDATION
Structure design
1
The goal of the regulation of the design of development within
The proposed storage building does not
Revise the architectural
the designated Entrance Corridors is to insure that new
reflect the traditional architecture of the
design to reflect the
development within the corridors reflects the traditional
area. Breaking down the mass into more
traditional architecture of
architecture of the area. Therefore, it is the purpose of ARB
regular forms, using more consistent
the area. Consider local
review and of these Guidelines, that proposed development
recesses and projections across the
historic commercial and
within the designated Entrance Corridors reflect elements of
elevations, and providing additional
industrial architecture as
design characteristic of the significant historical landmarks,
upper story treatments would be
precedents for breaking
buildings, and structures of the Charlottesville and Albemarle
appropriate. Local historic commercial
down the mass and
area, and to promote orderly and attractive development
and industrial architecture could be
employing appropriate
within these corridors. Applicants should note that replication
precedents for appropriate treatments.
architectural forms and
of historic structures is neither required nor desired.
Orderly and attractive development will
features.
2
Visitors to the significant historical sites in the Charlottesville
and Albemarle area experience these sites as ensembles of
depend in part on an appearance that is
Show how the proposed
buildings, land, and vegetation. In order to accomplish the
compatible with surrounding
architectural design is
integration of buildings, land, and vegetation characteristic of
development.
compatible with nearby
these sites, the Guidelines require attention to four primary
development.
factors: compatibility with significant historic sites in the area;
the character of the Entrance Corridor; site development and
layout; and landscaping.
3
New structures and substantial additions to existing structures
should respect the traditions of the architecture of historically
significant buildings in the Charlottesville and Albemarle area.
Photographs of historic buildings in the area, as well as
drawings of architectural features, which provide important
examples of this tradition are contained in Appendix A.
4
The examples contained in Appendix A should be used as a
guide for building design: the standard of compatibility with
the area's historic structures is not intended to impose a rigid
design solution for new development. Replication of the
design of the important historic sites in the area is neither
intended nor desired. The Guideline's standard of
compatibility can be met through building scale, materials,
and forms which may be embodied in architecture which is
contemporary as well as traditional. The Guidelines allow
individuality in design to accommodate varying tastes as well
asspecial functional requirements.
9
Building forms and features, including roofs, windows, doors,
The proposed building design does not
Revise the architectural
materials, colors and textures should be compatible with the
have a strong connection to historic
design to more
forms and features of the significant historic buildings in the
architecture of the area. It uses a few
successfully use
area, exemplified by (but not limited to) the buildings
architectural elements that appear in
architectural forms and
described in Appendix A [of the design guidelines]. The
traditional architecture — pilasters and
features, colors and
standard of compatibility can be met through scale, materials,
tower features at the corners — but the
materials, to reflect the
and forms which may be embodied in architecture which is
overall effect is a contemporary building
historic architecture of
contemporary as well as traditional. The replication of
with applied architectural elements. The
the area. Simplify the
important historic sites in Albemarle County is not the
applied elements are an attempt to
design while relieving
objective of these guidelines.
relieve blankness and improve scale, but
many of them appear to have no purpose
blankness and expressing
human scale.
11
The overall design of buildings should have human scale.
Scale should be integral to the building and site design.
and result in complicated elevations that
read as overly busy and jumbled. The
Revise the distribution of
12
Architecture proposed within the Entrance Corridor should use
forms, shapes, scale, and materials to create a cohesive whole.
perspectives suggest that the blockiness
building materials to help
of the building mass will still be the
establish a cohesive
primary impression of the structure. The
whole.
design does not appear as a cohesive
whole.
"Light stone" -colored corrugated metal
wall panels, two shades of red brick, and
gray split faced block are the primary
materials. The stacking of the materials
contributes to the disjointed appearance.
Although the red brick is a nod to
traditional materials of the area, the
renderings suggest that this visually
darker material is too heavy in its
proposed location. The gray split faced
block is expected to have an unfinished
appearance that is not appropriate for the
EC. Corrugated metal is not typically
considered an appropriate material for
the ECs due to its utilitarian character. A
minor amount (compared to the amount
of other proposed materials with historic
precedent) of corrugated metal might be
acceptable in a revised design that more
successfully uses traditional architectural
forms and features to break up the
building mass and relate to local historic
recedentS.
13
Any appearance of "blankness" resulting from building design
Blankness is present in the design.
should be relieved using design detail or vegetation, or both.
14
Arcades, colonnades, or other architectural connecting devices
Connecting devices are not provided.
should be used to unify groups of buildings within a
development.
15
Trademark buildings and related features should be modified
It isn't clear from the submittal whether
to meet the requirements of the Guidelines.
or not the proposed design has been
constructed in other localities.
16
Window glass in the Entrance Corridors should not be highly
Window glass has not been addressed in
Provide specifications for
tinted or highly reflective. Window glass in the Entrance
this submittal.
proposed window glass.
Corridors should meet the following criteria: Visible light
Show that VLT will not
transmittance (VLT) shall not drop below 40%. Visible light
drop below 40% and
reflectance (VLR) shall not exceed 30%. Specifications on the
VLR will not exceed
proposed window glass should be submitted with the
30%. Glass should be
application for final review.
clear, without tint. If
tinted glass is proposed,
provide a sample for
review. Add the standard
window glass note to the
architectural plans.
5
It is also an important objective of the Guidelines to establish
Buildings in the immediate context of
Show how the proposed
a pattern of compatible architectural characteristics throughout
this site include a vacant commercial
architectural design is
the Entrance Corridor in order to achieve unity and coherence.
building and the previous Rexel, now
compatible with the
Building designs should demonstrate sensitivity to other
Flow, fronting Rt. 20 to the west, and the
designs of nearby
nearby structures within the Entrance Corridor. Where a
Mazda dealership at the Rt. 20/Rt. 250
development.
designated corridor is substantially developed, these
intersection. On Rt. 250 to the south is
Guidelines require striking a careful balance between
the Goodwill building. The Pantops
harmonizing new development with the existing character of
Corner hotel is under review on the
the corridor and achieving compatibility with the significant
parcel to the northeast. Wawa is under
historic sites in the area.
review on the parcel to the southeast. It
is not clear from the submittal that the
10
Buildings should relate to their site and the surrounding
context of buildings.
proposed design relates to other existing
or proposed nearby development.
Accessory structures and equipment
17
Accessory structures and equipment should be integrated into
Equipment is not shown on the plan.
Show the locations of all
the overall plan of development and shall, to the extent
There is potential for rooftop equipment
ground- and building -
possible, be compatible with the building designs used on the
to be visible to westbound traffic on Rt.
mounted equipment on
site.
250.
the plans. Show how
visibility from the ECs
18
The following should be located to eliminate visibility from the
Entrance Corridor street. If, after appropriate siting, these
will be eliminated.
features will still have a negative visual impact on the Entrance
Corridor street, screening should be provided to eliminate
visibility. a. Loading areas, b. Service areas, c. Refuse areas, d.
Storage areas, e. Mechanical equipment, f. Above -ground
utilities, and g. Chain link fence, barbed wire, razor wire, and
similar security fencing devices.
19
Screening devices should be compatible with the design of the
buildings and surrounding natural vegetation and may consist
of: a. Walls, b. Plantings, and c. Fencing.
21
The following note should be added to the site plan and the
The note does not appear on the plan.
Add the standard
architectural plan: "Visibility of all mechanical equipment
mechanical equipment
from the Entrance Corridor shall be eliminated."
note to the plan.
22-
Lighting
Lighting is not addressed in the current
Provide a complete
31
submittal.
lighting plan with the
final site plan.
Landscaping
7
The requirements of the Guidelines regarding landscaping are
The current plan provides no trees along
Provide planting area and
intended to reflect the landscaping characteristic of many of
the south or west elevations of the
trees along the west side
the area's significant historic sites which is characterized by
proposed building or the west side of the
of the parcel and the
large shade trees and lawns. Landscaping should promote
parking areas. Trees will be needed in
south side of the building.
visual order within the Entrance Corridor and help to integrate
these locations to integrate the building
buildings into the existing environment of the corridor.
into the surroundings.
8
Continuity within the Entrance Corridor should be obtained by
planting different types of plant materials that share similar
characteristics. Such common elements allow for more
flexibility in the design of structures because common
landscape features will help to harmonize the appearance of
development as seen from the street upon which the Corridor
is centered.
32
Landscaping along the frontage of Entrance Corridor streets
This future parcel will have no EC
None.
should include the following:
frontage.
a. Large shade trees should be planted parallel to the Entrance
Corridor Street. Such trees should be at least 3%2 inches caliper
(measured 6 inches above the ground) and should be of a plant
species common to the area. Such trees should be located at
least every 35 feet on center.
b. Flowering ornamental trees of a species common to the area
should be interspersed among the trees required by the preceding
paragraph. The ornamental trees need not alternate one for one
with the large shade trees. They may be planted among the large
shade trees in a less regular spacing pattern.
c. In situations where appropriate, a three or four board fence
or low stone wall, typical of the area, should align the frontage
of the Entrance Corridor street.
d. An area of sufficient width to accommodate the foregoing
plantings and fencing should be reserved parallel to the
Entrance Corridor street, and exclusive of road right-of-way
and utility easements.
33
Landscaping along interior roads:
Trees are shown along Pantops Corner
Revise the plan to
a. Large trees should be planted parallel to all interior roads.
Way, but there are grading and retaining
maintain grading and
Such trees should be at least 2%2 inches caliper (measured six
wall conflicts. The Pantops Corner Hotel
retaining walls outside
inches above the ground) and should be of a plant species
site plan provides a sidewalk along
the driplines of trees to
common to the area. Such trees should be located at least
Pantops Corner Way.
remain. Show tree
every 40 feet on center.
protection fencing on, and
coordinated throughout,
34
Landscaping along interior pedestrian ways:
a. Medium trees should be planted parallel to all interior
the grading, landscaping
pedestrian ways. Such trees should be at least 2'/2 inches
and erosion and sediment
caliper (measured six inches above the ground) and should be
control plans.
of a species common to the area. Such trees should be located
at least every 25 feet on center.
35
Landscaping of parking areas:
12 parking spaces are provided. Two
Provide a large shade
a. Large trees should align the perimeter of parking areas,
trees are shown at the ends of the 4-space
tree, 2'/2" caliper at
located 40 feet on center. Trees should be planted in the
row. A large tree should be provided on
planting, at the middle of
interior of parking areas at the rate of one tree for every 10
the north side of the 4-space row.
the north side of the 4-
parking spaces provided and should be evenly distributed
space parking row.
throughout the interior of the parking area.
No perimeter trees are provided on the
b. Trees required by the preceding paragraph should measure
west side of the parking area. Insufficient
Provide large shade trees,
2'/2 inches caliper measured six inches above the ground);
planting area is provided.
2'/2" caliper at planting,
should be evenly spaced; and should be of a species common
40' on center, along the
to the area. Such trees should be planted in planters or
west side of the parking
medians sufficiently large to maintain the health of the tree
area. Revise the plan to
and shall be protected by curbing.
provide sufficient
c. Shrubs should be provided as necessary to minimize the
planting area.
parking area's impact on Entrance Corridor streets. Shrubs
should measure 24 inches in height.
36
Landscaping of buildings and other structures:
No trees are provided on the south or
Provide trees along the
a. Trees or other vegetation should be planted along the front
west sides of the building.
south and west sides of
of long buildings as necessary to soften the appearance of
the building to help
exterior walls. The spacing, size, and type of such trees or
soften the building's
vegetation should be determined by the length, height, and
appearance. Revise the
blankness of such walls.
plan to provide sufficient
b. Shrubs should be used to integrate the site, buildings, and
planting area.
other structures; dumpsters, accessory buildings and
structures; "drive thru" windows; service areas; and signs.
Shrubs should measure at least 24 inches in height.
37
Plant species: a. Plant species required should be as approved
Plant species are not yet identified.
Provide a complete
by the Staff based upon but not limited to the Generic
landscape schedule with
Landscape Plan Recommended Species List and Native Plants
the final site plan.
or Virginia Landscapes (Appendix D .
38
Plant health: The following note should be added to the
The note does not appear on the plan.
Add the standard plant
landscape plan: "All site plantings of trees and shrubs shall be
health note to the plan.
allowed to reach, and be maintained at, mature height; the
topping of trees is prohibited. Shrubs and trees shall be
pruned minimally and only to support the overall health of the
plant.,,
Site Development and layout
Development pattern
6
Site development should be sensitive to the existing natural
The new parcel on which the storage
See recommendations
landscape and should contribute to the creation of an
building would be constructed is situated
above.
organized development plan. This may be accomplished, to
to the southwest of the Pantops Corner
the extent practical, by preserving the trees and rolling terrain
Hotel parcel, northwest of the Pantops
typical of the area; planting new trees along streets and
Wawa site, and northeast of the
pedestrian ways and choosing species that reflect native forest
Goodwill and Flow Mazda sites. There
elements; insuring that any grading will blend into the
are stands of mature trees visible from
surrounding topography thereby creating a continuous
both corridors that would be removed to
landscape; preserving, to the extent practical, existing
accommodate the building. Retaining
significant river and stream valleys which may be located on
walls of considerable size are proposed;
the site and integrating these features into the design of
trees and rolling terrain are not being
surrounding development; and limiting the building mass and
preserved. As proposed, the storage
height to a scale that does not overpower the natural settings
building will rise above existing adjacent
of the site, or the Entrance Corridor.
buildings. With a boxy mass and large
areas of blankness, the building may
appear over -scaled.
39
The relationship of buildings and other structures to the
The storage building is proposed in a
None.
Entrance Corridor street and to other development within the
location that aligns with the neighboring
corridor should be as follows:
buildings. It is parallel to the Rt. 250 EC,
a. An organized pattern of roads, service lanes, bike paths, and
but not to the Rt. 20 EC, which curves in
pedestrian walks should guide the layout of the site.
this area. The site would be accessed
b. In general, buildings fronting the Entrance Corridor street
from Pantops Corner Way, a new private
should be parallel to the street. Building groupings should be
street associated with the Pantops Corner
arranged to parallel the Entrance Corridor street.
Hotel and Wawa developments. No open
c. Provisions should be made for connections to adjacent
space is provided. There are stands of
pedestrian and vehicular circulation systems.
mature trees visible from both corridors
d. Open spaces should be tied into surrounding areas to
that would be removed to accommodate
provide continuity within the Entrance Corridor.
the building. No views are expected to be
e. If significant natural features exist on the site (including
impacted.
creek valleys, steep slopes, significant trees or rock
outcroppings), to the extent practical, then such natural
features should be reflected in the site layout. If the provisions
of Section 32.5.2.n of the Albemarle County Zoning
Ordinance apply, then improvements required by that section
should be located so as to maximize the use of existing
features in screening such improvements from Entrance
Corridor streets.
f. The placement of structures on the site should respect
existing views and vistas on and around the site.
Site Grading
40
Site grading should maintain the basic relationship of the site to
The proposed development includes the
Terrace the 10' retaining
surrounding conditions by limiting the use of retaining walls and
extensive use of retaining walls. A wall
wall so that no wall
by shaping the terrain through the use of smooth, rounded land
extends along the full length of the west
exceeds 6' in height, and
forms that blend with the existing terrain. Steep cut or fill
side of the site, wrapping around the
plant the terraces.
sections are generally unacceptable. Proposed contours on the
southern and northern corners. The
Alternatively, revise the
grading plan shall be rounded with a ten foot minimum radius
southern half of the wall reaches 10'
plan to provide trees at
where they meet the adjacent condition. Final grading should
high. It is not terraced, is expected to
the base of the 10'
achieve a natural, rather than engineered, appearance. Retaining
have some visibility from the Rt. 20 EC
retaining wall, and
walls 6 feet in height and taller, when necessary, shall be
(buildings fronting Rt. 20 will block
sufficient planting area
terraced and planted to blend with the landscape.
much of it), and has pairs of shrubs at the
for the trees.
base, with groups of shrubs above. Trees
at the base would provide better
Ensure that planting at
mitigation for the lack of terracing. The
the retaining wall terraces
northern half of the wall includes two
is sufficient to mitigate
terraced 6' walls. Retaining wall material
the height and length of
is not identified on the plan. The shrub
the walls.
planting of the terraced walls seems
sparse. Contours are rounded.
Indicate the retaining wall
material on the plan.
Provide a sample for
review if other than Eagle
Bay Anchor Diamond Pro
James River.
41
No grading, trenching, or tunneling should occur within the drip
Three trees located along Pantops Corner
Revise the plan to
line of any trees or other existing features designated for
Way, currently proposed on the Pantops
maintain grading and
preservation in the final Certificate of Appropriateness.
Corner Hotel site plan, would be
retaining walls outside
Adequate tree protection fencing should be shown on, and
removed to accommodate the entrance
the driplines of trees to
coordinated throughout, the grading, landscaping and erosion
into the storage site. Two of those trees
remain. Show tree
and sediment control plans.
are compensated for in the storage plan
with new trees. Proposed grading is
protection fencing on, and
coordinated throughout,
42
Areas designated for preservation in the final Certificate of
Appropriateness should be clearly delineated and protected on
shown within the dripline of five
the grading, landscaping
the site prior to any grading activity on the site. This
additional trees (also shown on the
and erosion and sediment
protection should remain in place until completion of the
Pantops Corner Hotel site plan), along
control plans.
development of the site.
Pantops Corner Way and the proposed
retaining wall is shown within 3' of the
43
Preservation areas should be protected from storage or
movement of heavy equipment within this area.
trunk of one of those trees. The relative
timing of the construction of the various
Pantops Corner projects is unclear. If the
trees will be installed with the hotel plan
prior to the development of the storage
site, the grading and retaining wall on the
storage plan must be more fully
coordinated with that landscaping and
tree protection fencing must be shown
for the Pantops Corner Way trees.
20
Surface runoff structures and detention ponds should be
Stormwater would tie into the system
None.
designed to fit into the natural topography to avoid the need for
proposed along Pantops Corner Way,
screening. When visible from the Entrance Corridor street, these
connecting near the north end of the
features must be fully integrated into the landscape. They
proposed parking area.
should not have the appearance of engineered features.
44
Natural drainage patterns (or to the extent required, new
drainage patterns) should be incorporated into the finished site
to the extent possible.
SUMMARY OF RECOMMENDATIONS
Staff recommends the following as the primary points of discussion:
1. The architectural design of the storage building; compatibility with the traditional architecture of the area
2. The choice and distribution of building materials
3. Compatibility with surrounding (existing/proposed) development
4. The use of retaining walls, non -terraced walls over 6' tall, landscaping of the retaining walls
Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee:
• Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and recommended conditions of initial plan approval:
o Prior to Initial Plan approval the following items shall be resolved to the satisfaction of the ARB: None.
• Regarding recommendations on the plan as it relates to the guidelines: None.
• Regarding conditions to be satisfied prior to issuance of a grading permit:
1. Maintain grading and retaining walls outside the driplines of trees to remain. Show tree protection fencing on, and coordinated throughout, the
grading, landscaping, and erosion and sediment control plans.
• Regarding the final site plan submittal:
o A Certificate of Appropriateness is required prior to final site plan approval. The following items and all items on the ARB Final Site Plan
Checklist must be addressed:
1. Revise the architectural design to reflect the traditional architecture of the area. Consider local historic commercial and industrial
architecture as precedents for breaking down the mass and employing appropriate architectural forms and features.
2. Show how the proposed architectural design is compatible with nearby development.
10
3. Revise the architectural design to more successfully use architectural forms and features, colors and materials, to reflect the historic
architecture of the area. Simplify the design while relieving blankness and expressing human scale.
4. Revise the distribution of building materials to help establish a cohesive whole.
5. Provide specifications for proposed window glass. Show that VLT will not drop below 40% and VLR will not exceed 30%. Glass should
be clear, without tint. If tinted glass is proposed, provide a sample for review. Add the standard window glass note to the architectural
plans: "Visible light transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 3001o. "
6. Show how the proposed architectural design is compatible with the designs of nearby development.
7. Show the locations of all ground- and building -mounted equipment on the plans. Show how visibility from the ECs will be eliminated.
8. Add the standard mechanical equipment note to the plan: "Visibility of all mechanical equipment from the Entrance Corridor shall be
eliminated. "
9. Provide a complete lighting plan with the final site plan.
10. Provide planting area and trees along the west side of the parcel and the south side of the building.
11. Revise the plan to maintain grading and retaining walls outside the driplines of trees to remain. Show tree protection fencing on, and
coordinated throughout, the grading, landscaping and erosion and sediment control plans.
12. Provide a large shade tree, 21/2" caliper at planting, at the middle of the north side of the 4-space parking row.
13. Provide large shade trees, 21/2" caliper at planting, 40' on center, along the west side of the parking area. Revise the plan to provide
sufficient planting area.
14. Provide trees along the south and west sides of the building to help soften the building's appearance. Revise the plan to provide
sufficient planting area.
15. Provide a complete landscape schedule with the final site plan.
16. Add the standard plant health note to the plan: `All site plantings of trees and shrubs shall be allowed to reach, and be maintained at,
mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of
the plant. "
17. Terrace the 10' retaining wall so that no wall exceeds 6' in height, and plant the terraces. Alternatively, revise the plan to provide trees at
the base of the 10' retaining wall, and sufficient planting area for the trees.
18. Ensure that planting at the retaining wall terraces is sufficient to mitigate the height and length of the walls.
19. Indicate the retaining wall material on the plan. Provide a sample for review if other than Eagle Bay Anchor Diamond Pro James River.
20. Revise the plan to maintain grading and retaining walls outside the driplines of trees to remain. Show tree protection fencing on, and
coordinated throughout, the grading, landscaping and erosion and sediment control plans.
11
TABLE A
This report is based on the following submittal items:
Sheet #
Drawing Name
Drawing Date/Revision Date
C1
Cover Sheet
2/19/2019
C2
Proposed Boundary Line Adjustment
2/19/2019
C3
I Existing Conditions & Demo Plan
2/19/2019
C4
Revised Conditions & Demo Plan
2/19/2019
C5
Site Plan
2/19/2019
C6
Site Details
2/19/2019
-
North, south, east and west elevations
2/18/2019
12