HomeMy WebLinkAboutZMA201900004 Review Comments Zoning Map Amendment 2019-06-19Short Review Comments Report for:
ZMA201900004 ]- BREEZY HILL
SubApplication Type:
Date Completed: 05-06-2019
Reviewer: Michael Dellinger Division: CDD Inspections
Review Status: See Recommendations
Reviews Comments: 1will perform review when official site plan is submitted.
Date Completed: 05-13-2019
Reviewer: Shawn Maddox Division: Fire Rescue
Review Status:
Reviews Comments:
See Recommendations
Fire Rescue has no objections to the Zoning Map amendment as submitted but will offer the following
comments that will be addressed during the site plan review process:
1. Prior to the issuance of the 31 st building permit the second entrance/exit shall be completed.
2. Travel ways must provide a minimum of 20' clear travel width, on street parking arrangements
should take this in to account.
3. Adequate fire flow based on building square footage will be required along with a fire flow test prior
to final acceptance.
4. Minimum turning radius shall be 25'
5. Any cul-de-sac or turn arounds will be required to meet current fire code requirements.
Date Completed: 05-15-2019
Reviewer: Richard Nelson Division: ACSA
Review Status: See Recommendations
Reviews Comments:
Date Completed
Reviewer:
Review Status:
Reviews Comments:
'\CSA comments embedded in Review Comment Letter #1 (dated 5/31/2019) and in Laserfiche
Neblink (dated 5/15/2019).
06-11-2019
Division: RWSA
See Recommendations
Dyon Vega, Civil Engineer for RWSA, commented on 6/11/2019 that this proposal requires RWSA
:,apacity Certification.
Date Completed: 06-06-2019
Reviewer: Adam Moore Division: VDOT
Review Status: See Recommendations
Reviews Comments:
Date Completed:
Reviewer:
Review Status:
Reviews Comments:
Date Completed:
Reviewer:
Review Status:
Page: 1 of 2
'\dam Moore, PE, provide written review comments on 6/6/2019; those comments are available in
_aserfiche Weblink. These three comments related to: entrance spacing requirements; TIA
Drojections for increased peak -hour traffic volume; and the left turn warrant analysis, including
VDOT's recommendation to construct a left turn lane at the proposed Running Deer entrance (if new
sntrance is approved by VDOT at that location).
Frank Pohl Division: CDD Engineering
Pending
04-25-2019
Francis MacCall Division: CDD Admin Zoning Review
QC OK
County of Albemarle
Printed On: September 03, 2019
Reviews Comments:
..................................................................................
Date Completed:
Reviewer:
Review Status:
Reviews Comments:
..................................................................................
Date Completed:
Reviewer:
Review Status:
Reviews Comments:
Date Completed:
Reviewer:
Review Status:
Reviews Comments:
Date Completed:
Reviewer:
Review Status:
Reviews Comments:
05-31-2019
Tim Padalino Division: CDD Planning
Requested Changes
05-29-2019
Frank Pohl Division: CDD Engineering
See Recommendations
These comments can be addressed during subdivision/VSMP reviews.
- The limits of floodway and base flood elevation must be determined by the applicant prior to VSMP,
subdivision or site plan approval [18-30.3.13(C)1]. Grading, even for a pedestrian trail, cannot occur
within the regulatory floodway unless it will be maintained by the County; however, a primitive trail is
allowed in the floodway.
- It is recommended that proposed grades do not exceed 3:1.
- Documentation that existing ponds meet current SWM construction standards may be required.
Francis MacCall Division: CDD Zoning
Pending
Tim Padalino Division: CDD Planning
RD
\pplicants requested in writing (via email on 7/16/2019) a deferral pursuant to Zoning Ordinance
Section 33.52; applicants have requested BOS action no later than 11/30/2019.
Date Completed:
Reviewer: Tim Padalino
Review Status: Pending
Reviews Comments:
Division: CDD Planning