Loading...
HomeMy WebLinkAboutARB201900028 Action Letter 2019-05-07COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone 434 296-5532 Fax 434 972-4126 May 7, 2019 Riki Van-Niekerk Roudabush, Gale & Assoc., Inc. 172 South Pantops Drive Charlottesville, VA 22911 RE: ARB-2019-00028: Georgetown Hydraulic Professional Office, initial Site Plan (TM/Parcel 060 F0000000300) Dear Mr. Van-Niekerk, At its meeting on Monday, May, 6, 2019 the Albemarle County Architectural Review Board unanimously voted to forward the following recommendations on the above -noted Initial Site Development Plan to the agent for the Site Review Committee: • Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and recommended conditions of initial plan approval: None. Note that a Certificate of Appropriateness is required prior to final site plan approval. • Regarding recommendations on the plan as it relates to the guidelines: None. • Regarding conditions to be satisfied prior to issuance of a grading permit: 1. Provide sufficient tree protection fencing around those trees to be preserved and clearly differentiate between trees to be removed and those to be retained on Sheet 2 of the site plan set. • Regarding the final site plan submittal: 1. Architecture and landscaping will be reviewed with a future submittal. A Certificate of Appropriateness is required prior to final site plan approval. 2. Submit material and color samples, dimensioned elevations, and floor plans of the apartment buildings for review. 3. Provide the standard window glass note to the architectural drawings: Window glass in the Entrance Corridors should meet the following criteria: Visible light transmittance (VL7) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%. 4. If a refuse area is proposed, show it on the site plan and include details of the dumpster enclosure in the site plan. 5. Substitute evergreen trees with a height over 102 at maturity for the 5 viburnums presently proposed on the southeast corner and the 3 viburnums presently proposed on the northeast corner of the building. 6. Provide the top- and bottom -of -wall heights for the retaining walls surrounding the proposed ground -mounted HVAC units in the southeast and northeast corners of the building. Provide material samples for the retaining wails and provide a detail of the walls on the site plan set. 7. Relocate the landscape island at the western edge of the parking area away from the stormwater outlet. B. Include the mechanical equipment note on the site plan set and architectural drawings: Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 9. Provide a lighting plan for review that includes a photometric plan, a luminalre schedule, and manufacturer's cut sheets for all proposed wall -mounted and freestanding fixtures. 10. Revise the plan to provide the standard lighting note: Each outdoor luminaire equipped with a lamp that emits 3. 000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one half footcandle. 11. Ensure that no proposed tree conflicts with an existing or proposed utility or its easement and that large shade trees are placed a minimum of 7 feet from the center of a utility line. If trees are placed in easements, provide documentation from the easement holders that the vegetation is permissible. 12. Revise the site plan set to show all utilities and easements consistently throughout the site plan set. 13. Provide a note that the ginkgoes planted will not be female. 14. Provide four trees in the parking area at a minimum of 2.5" caliper. Update the plant schedule on Sheet 5 to reflect this change. 15. Consider substituting locally native species for the non-native plants proposed. 16. Provide at least two more evergreen shrub species so that no one species of shrub proposed exceeds, in number; one -quarter of the total number of shrubs proposed. 17. Rectify errors in the plant schedule on Sheet 5. 18. Provide all site elements required by the Proffers and Code of Development approved with ZMA-2016-14, including a widened sidewalk; an entry plaza with picnic tables; a bicycle rack: and a bus shelter. Show these site elements on the site plan. 19. Provide additional vegetation on the retaining walls in the southwest and northwest corners of the parking area. 20. Provide details of the proposed retaining walls in the site plan set and submit material and color samples for review. Retaining walls over six feet must be terraced and landscaped. 21. Provide sufficient tree protection fencing around those trees to be preserved and clearly differentiate between trees to be removed and those to be retained on Sheet 2 of the site plan set. You may submit your application for continued ARB review at your earliest convenience. Application forms, checklists and schedules are available on-line at www.albemarle.oEg/ARB. Please be certain that your ARB submittal addresses the above -noted issues. If you have any questions concerning any of the above, please feel free to contact me. Sincerely, Margaret Maliszewski Chief of Planning/Resource Management 434-296-5832 x3276 mmaliszewski@albemarle.org cc: CKK 2 LLC 1747 Earlysville Road Charlottesville, VA 22901 File