Site Plan Amendment Review
Project title:
Oakleigh — Minor Site Plan Amendment
Project file number:
SDP201800091
Plan preparer:
Steve Edwards[steve(a)edwarddesienstudio.com]
4936 Old Boonesboro Road, Lynchburg VA 24503
Alan Franklin, P.E., LLC [alan(a)alanfranklinpe.com]
427 Cranberry Lane, Crozet VA 22932
Owner or rep.:
Oakleigh Albemarle LLC — 690 Berkmar Circle / Charlottesville, VA 22901
Plan received date:
20 Dec 2018
(Rev. 1)
17 Apr 2019
Date of comments:
7 Feb 2019
(Rev. 1)
10 May 2019
Plan Coordinator:
Paty Saternye
Reviewer:
John Anderson
SDP201800091
Compare approved impervious area (224,639 ft2) with proposed Amendment (232,586 ft2); a slight 3.4%
increase. Amend VSMP/WPO Plan for this site plan, including VSMH Vol. 2 Appendix 5D worksheets.
(Note: proposed routing of paved surface runoff directly into a Level-1 biofilter requires pre-treatment)
Link: https://www.deq.vir ie•nia.2ov/Portals/O/DEO/Water/Publications/HndbkVolumeI.pdf - p. 3.11-14 and
FIG. 3.11-7. "Like other infiltration basins, bioretention basins must always be preceded by a pretreatment
facility to remove grease, oil, floatable organic material, and settleable solids..."
SDP201700005, Sheet 2: (Rev. 1) Comment persists. WP02017-00023, Amendment 2, is under review.
BREAKDOWN: BUILDINGS: J 79,924 11.83 21%
ROADSISIDEWALKS:
PAVED PARKING/ROADS 121,505 2.79 32%
SIDEWALKS: 23,210 0.53 6%
PERVIOUS AREA;OPEN SPACE: 159-*4F— 3.67 42%
TOTAL SITE ACREAGE: 384,286 8.822 100%
NOTES
1. The minimum required open space is 20 % (per Section 20A.9.a.1 )
2. Pervious arearOpen Space includes land within ROW and on any individual lot. `• v?
3. Common open space excludes land within ROW and on inclMdual lots.
4. Lots Include only those indnidual lots and nothing more. i
2. Include reference to approved VSMP/WPO for Oakleigh: list WP0201700023, Approved 3/26/18, as an
associated plan. (Rev. 1) Addressed.
Engineering Review Comments
Page 2 of 3
Sheet 4
3. Provide gutter along Eckerson Court, from Int. with Nichols Court, to parking area entrance at proposed
apartments. Ref. 18-4.12.15.g. Label curb and gutter using VDOT nomenclature, CG-7, for example.
(Rev. 1) Partially addressed. Applicant response: `We are using CG-3 so we wouldn't have to install
gutter on the access.' Asfollow-up: Please revise CG-3 to CG-6. Ref. 18-32.7.2.2.a. which references
Chapter 14. Please ref. 14-412.13. which states VDOT standards apply. Please ref. VDOT Road Design
Manual, Appendix B(1) -pg. B(1)-7, Table 1, Geometric Design Standards for Residential and Mixed Use
Subdivision Streets (GS-SSAR), Curb and Gutter section. Gutter is required. It is optimistic to assume
permeable pavers will be maintained over the life of this facility to the point design storm events do not
cause runoff requiring drainage design that prevents flooding at low point, Eckerson Court. Provide CG-6.
4. Concrete dumpster pad does not appear to extend 8' from back face of enclosure gates to edge of asphalt
surface. Revise to obtain min. 8' length, measured from back face of enclosure gates to edge of asphalt.
Ref. 18-4.12.19. (Rev. 1) Addressed.
5. Dimension Eckerson Court travelway width. Provide width label. (Rev. 1) Addressed.
6. Revise Note 5., Restrictions/Requirements/Notes: to read `All travelways are private with public access
easements over them.' (Rev. 1) Not addressed.
7. Label emergency access concrete apron /entrance at Rio Road using VDOT nomenclature (CG-9a, for
example). Ref. Final Site Plan checklist, pg. 2, entrances and right-of-way improvements. (Rev. 1)
Addressed.
8. SDP201700005, Oakleigh Major Site Plan Amendment does not appear to include retaining wall design.
Provide retaining wall design. See Final Site Plan and Retaining Wall checklists (attached to this Memo).
(Rev. 1) Withdrawen. Applicant response: `Was provided to the County on 4/20/2017.'
9. Provide L X W (Typ.) dimensions for the three proposed parking spaces just west of the emergency access.
(Rev. 1) NA. Spaces removed.
10. Provide auto turn for typical passenger vehicles at Sta. 12+50f, Eckerson Ct, to show that a car exiting may
pass a car entering without striking curb or parked vehicles, with at least 2' clearance between vehicles.
Revise design to provide minimum 2' clearance between two typ. passenger vehicles at this location. (Rev.
1) Withdrawn. Applicant response: `This is no longer an issue with circulation being one way towards the
dumpster.'
11. Label travelway width between Sta. 12+50(f) and dumpsters, Eckerson Court (appears to be —14' FC-FC).
(Rev. 1) Addressed.
12. This section of travelway is too narrow for two-way travel. Provide signs indicating `one-way' travel
unless inconsistent with site plan requirements or Albemarle County Planning Division review, or policy.
(Rev. 1) Addressed.
13. Provide auto -turn for waste management vehicle (Typ.) to illustrate how WM vehicles may perform reverse
movement to exit this area without striking pedestrians, curbs, or parked vehicles. (Rev. 1) Addressed.
14. Revise subterranean parking drive aisle dimension to 24' (apparent typo). (Rev. 1) Addressed.
15. Revise 9' w (non-HC) parking space (adjacent to 8' w HC space) to 10' width. Ref. 18-4.12.16.c.1. (Rev.
1) Addressed.
16. Label sidewalk width, for walk located north of Eckerson Court. (Rev. 1) Addressed.
17. Provide curb cut required for drainage to bioretention midway along 8 parking spaces south of apartments.
(Rev. 1) Addressed.
18. Provide bioretention basin pre-treatment for this (asphalt surface) storm runoff, item above. (Rev. 1)
Partially addressed. Applicant response: `Pre-treatment for this bioretention basin is based on the old
stormwater regulations. It is a forebay as shown on the plans.' Additional comments possible with VSMP
/WPO2017-00023, Amendment 2. Comments will be based on VSMH, First Edit., 1999, Min. Std. 3.11.
19. Provide `do not enter' sign at south exit of subterranean parking. Alternatively, revise travelway width,
north side of apartments to 20', min. Ref. 18-4.12.17.c.1.-2. (Rev. 1) Addressed.
Sheet 5
Engineering Review Comments
Page 3 of 3
20. Provide storm inlets and conveyance from paved surface of Eckerson Court. Please ref. proposed profile.
From proposed H.P. Sta. 11+20, surface runoff flows west, without any inlets on the travelway. This
runoff bypasses the parking area fronting east side of proposed apartments, and washes into a dumpster
enclosure. Provide VDOT storm drainage design, for both culvert pipes and inlets. Eckerson may (likely
will) flood and present hazard under proposed curb without gutter and inlet design. (Rev. 1) Not
addressed. Permeable pavers are likely to blind with debris if improperly maintained. In that case, surface
runoff has no outlet. Request GC -inlet design. Recommend —120' pipe from inlet at L.P. Eckerson Ct. Sta.
12+46 (f) to Str. H2. There is sufficient grade for mild slope between these points. Flooding at the low
point would strand residents of the apartment complex.
21. Revise I/8 (4" curb) detail to VDOT CG-7. Ref. 2016 Road and Bridge Standard, CG-7, 201.04, Rev. 9/06.
(Rev. 1) Partially addressed. As follow-up: Provide barrier -type curb appropriate to design speed. Ref.
Sheet 8, VDOT CG-3 detail, Note 5. Also, item 3. Comment is revised to request design provide CG-6.
22. Provide dumpster pad detail. Ref. 18-4.12.19. Specify /provide minimum 4" stone base, 6" concrete depth,
3000psi at 28 days, with minimum grid of wire reinforcing or #4 bars at 12" on center. Final Site Plan
checklist, p. 3, parking and circulation, item 8. (Rev. 1) Addressed.
23. Revise proposed grade so that Eckerson Court storm runoff does not wash through dumpster pad enclosure.
Collect and convey storm runoff to avoid spread greater than '/2 travel lane width + gutter pan. (Rev. 1)
Addressed.
Sheet 8:
24. Revise Ksag value, Eckerson Court, PVI Sta. 12+46 (K proposed = 5.00) to nearly approximate approved
site plan Ksag PVI Sta. 12+86, K=12.00. Recommend Ksag = 15.00 as a design target. (Rev. 1) Not
addressed. Applicant response: `We did not address this. When the townhomes became apartments, the
private street becomes more like a travelway and dropped the private road standards and feel is adequate
for this application.' Ref. code 18-32.7.2.2.a. which references Chapter 14. Please ref. 14-412.13. (Private
Streets) which states VDOT standards apply. Please address. Required for site plan approval.
25. Provide emergency access section (detail). (Rev. 1) Addressed.
26. Provide grasspave detail. (Rev. 1) Addressed.
27. Detail D/8: Include VDOT Class A3 General concrete design parameters; i.e., compressive strength, slump,
air, etc. Link: http://www.virginiadot.or,gNDOT/Business/asset_upload_fi1e41_3529.pdf , p. C-18. (Rev.
1) Not addressed. Include specifications for A3 general or paving concrete on plans for site plan approval.
This is a specification. Item missed on prior review that does not alter design and requires limited revision
appears basis of applicant response: `This detail has been approved twice in previous reviews and we feel
doesn't require being addressed at this time.'
28. Provide S1 Storey Streetguard (guardrail) detail, as well as technical information that demonstrates this
product is equivalent to VDOT Std. in terms of barrier protection. (Rev. 1) Addressed.
29. Nichols Court, Sta. 11+00(f): provide cross drain (VDOT CD-1, 2) at cut/fill transition. (Rev. 1)
Withdrawn. Review error: `This road has been built. This cannot be added.'
30. n approved VSMP Plan Amendment is required prior to Site Plan Amendment approval. (Rev. 1)
Comment persists. Applicant response: `Noted.' VSMP/WPO 2017-00023 is under review.
Please feel free to call if any questions. Thank you