Loading...
HomeMy WebLinkAboutARB201700094 Staff Report 2017-10-30 (3)1 ARCHITECTURAL REVIEW BOARD STAFF REPORT Project #/Name ARB-2017-94: Avinity Estates II, Initial Site Plan Review Type Initial Site Development Plan Parcel Identification 091000000016C0, 091000000016E0, 091000000016A0 Location North of Pebble Drive, west of Route 20 (Scottsville Road), south of the Kappa Sigma headquarters, and east of the original Avinity development which fronts Avon Street Extended Zoned Planned Residential Development (PRD), Entrance Corridor (EC) Owner/Applicant/Contact Avinity Estates LLC/ Riverbend Development Inc./Scott Collins Magisterial District Scottsville Proposal To construct a residential development with 63 single-family attached units, 30 townhouse units, and one clubhouse on combined 11.886 acres Context The property is a mix of wooded and open areas. Nearby is a mix of residential, institutional, and industrial uses. Property on the opposite side of Scottsville Road retains a rural character. ARB Meeting Date November 6, 2017 Staff Contact Heather McMahon 2 PROJECT HISTORY DATE APPLICATION RESULT 10/1/2014 ZMA-2013-16 Request to rezone 11.886 acres from R1 to PRD approved 3/21/2016 ARB-2015-120 ARB approved an Amendment to the townhome designs in Avinity Estates I 11/6/2017 ARB-2017-94 ARB will review the Initial Site Development Plan for Avinity Estates II This proposal is an extension of the original Avinity development that fronts Avon Street Extended and was reviewed and approved between 2007 and 2010. In November 2014, a Zoning Map Amendment (ZMA-2013-16) to rezone 11.886 acres between the Avinity I development and Route 20 (Scottsville Road) was approved. This development consists of 63 single-family attached units, 30 townhouse units, and a clubhouse with access to Route 20 as well as Avinity I. The ARB will review this development for the first time at the November 6, 2017 meeting. VISIBILITY The project area abuts the EC street (Route 20 South) in two places: 1) a pipe stem which holds an emergency access road north of the Kappa Sigma Headquarters property, and 2) 0.69 acres of open space with 260’ of frontage to the south of Kappa Sigma that includes one of three proposed stormwater management facilities, identified as “Proposed Dry Detention Basin B” (henceforth Basin B). The topography of the site rises steeply westward [Figure 1]; therefore, the roofs, sides, and upper portions of the rear elevations of the townhomes in Block D are expected to be visible, as will be the upper portions of the elevations of the homes behind the Kappa Sigma Headquarters property, which front Montague Street and lie in Blocks A, B and C. Basin B and the emergency entrance will also be visible. 3 Figure 1: The property in question rises steeply westward, suggesting that the majority of the proposed dwellings will be visible from the EC. As seen from Route 20 North, and Entrance Corridor. Photograph taken by H. McMahon, 10.26.17. 4 ANALYSIS Gray highlight = means the guideline can’t be reviewed at initial site plan stage, but recommendations can be provided for final Yellow highlight = means the guideline can only be reviewed for location/configuration at the initial plan stage Regular text = means the guideline can be reviewed at initial plan stage, can be made a condition of initial plan approval, and can be the basis for denial REF GUIDELINE ISSUE RECOMMENDATION GENERAL GUIDELINES Purpose 1 The goal of the regulation of the design of development within the designated Entrance Corridors is to insure that new development within the corridors reflects the traditional architecture of the area. Therefore, it is the purpose of ARB review and of these Guidelines, that proposed development within the designated Entrance Corridors reflect elements of design characteristic of the significant historical landmarks, buildings, and structures of the Charlottesville and Albemarle area, and to promote orderly and attractive development within these corridors. Applicants should note that replication of historic structures is neither required nor desired. The proposed development’s proximity to the Kappa Sigma Headquarters property could provide a neo-colonial design influence, while the historic building on TMP 91-16A could also provide design inspiration. (The existing house and outbuildings on TMP 91-16A are contributing resources to the Southern Albemarle Historic District. As per the proffers, the house will be documented before demolition.) It is likely, however, that the architecture will reflect those housing units built to the west, in Avinity’s first phase of development. [Figures 2 and 3] Submit architectural elevations and floor plans for review. 2 Visitors to the significant historical sites in the Charlottesville and Albemarle area experience these sites as ensembles of buildings, land, and vegetation. In order to accomplish the integration of buildings, land, and vegetation characteristic of these sites, the Guidelines require attention to four primary factors: compatibility with significant historic sites in the area; the character of the Entrance Corridor; site development and layout; and landscaping. 5 Figures 2 and 3: Architectural designs of townhomes at Avinity Estates I. Photographs taken by H. McMahon, 10.26.17. 6 Compatibility with significant historic sites: 3 New structures and substantial additions to existing structures should respect the traditions of the architecture of historically significant buildings in the Charlottesville and Albemarle area. Photographs of historic buildings in the area, as well as drawings of architectural features, which provide important examples of this tradition are contained in Appendix A. See above. See recommendation in #1. 4 The examples contained in Appendix A should be used as a guide for building design: the standard of compatibility with the area’s historic structures is not intended to impose a rigid design solution for new development. Replication of the design of the important historic sites in the area is neither intended nor desired. The Guideline’s standard of compatibility can be met through building scale, materials, and forms which may be embodied in architecture which is contemporary as well as traditional. The Guidelines allow individuality in design to accommodate varying tastes as well as special functional requirements. Compatibility with the character of the Entrance Corridor 5 It is also an important objective of the Guidelines to establish a pattern of compatible architectural characteristics throughout the Entrance Corridor in order to achieve unity and coherence. Building designs should demonstrate sensitivity to other nearby structures within the Entrance Corridor. Where a designated corridor is substantially developed, these Guidelines require striking a careful balance between harmonizing new development with the existing character of the corridor and achieving compatibility with the significant historic sites in the area. No architectural drawings have been submitted with this application, but the footprints suggest the townhomes will be 2- 3 stories tall, which is in keeping with the scale of other new developments along the ECs. See recommendation in #1. Site development and layout 6 Site development should be sensitive to the existing natural landscape and should contribute to the creation of an organized development plan. This may be accomplished, to the extent practical, by preserving the trees and rolling terrain typical of the area; planting new trees along streets and pedestrian ways and choosing species that reflect native forest elements; insuring that any grading will blend into the Topography at this site rises from approximately 500’ at Rt. 20 to 568’ at the western end of parcel 16A, and from 528’ at the east to 564’ at the west on parcel 16E. An organized pattern of roads planted with street trees is proposed, although significant grading of the hilly terrain will be required Submit at least four sight-line analyses taken from various points on Route 20 to verify visibility of the development from the EC. 7 surrounding topography thereby creating a continuous landscape; preserving, to the extent practical, existing significant river and stream valleys which may be located on the site and integrating these features into the design of surrounding development; and limiting the building mass and height to a scale that does not overpower the natural settings of the site, or the Entrance Corridor. to accommodate the development. Wooded areas will be removed. Site sections could help illustrate the relationship of the proposed grading and construction to the EC, and potential views from the EC. Structure design 9 Building forms and features, including roofs, windows, doors, materials, colors and textures should be compatible with the forms and features of the significant historic buildings in the area, exemplified by (but not limited to) the buildings described in Appendix A [of the design guidelines]. The standard of compatibility can be met through scale, materials, and forms which may be embodied in architecture which is contemporary as well as traditional. The replication of important historic sites in Albemarle County is not the objective of these guidelines. No architectural drawings have been supplied at this time, but the rear elevations of units 77-81 are expected to be visible from the EC as well as the side and rear elevations of lots 82-87. In addition, the rear elevations of lots 59-71 and the side elevations of 72-76 are expected to be visible from the EC. See recommendations in #1 and #6. 10 Buildings should relate to their site and the surrounding context of buildings. 11 The overall design of buildings should have human scale. Scale should be integral to the building and site design. 12 Architecture proposed within the Entrance Corridor should use forms, shapes, scale, and materials to create a cohesive whole. 13 Any appearance of “blankness” resulting from building design should be relieved using design detail or vegetation, or both. 14 Arcades, colonnades, or other architectural connecting devices should be used to unify groups of buildings within a development. 15 Trademark buildings and related features should be modified to meet the requirements of the Guidelines. 16 Window glass in the Entrance Corridors should not be highly tinted or highly reflective. Window glass in the Entrance Corridors should meet the following criteria: Visible light transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%. Specifications on No architectural drawings have been submitted with this application, so the note has not been provided. Add the standard window glass note to the architectural drawings. Provide manufacturer’s specifications for the window glass. 8 the proposed window glass should be submitted with the application for final review. Accessory structures and equipment 17 Accessory structures and equipment should be integrated into the overall plan of development and shall, to the extent possible, be compatible with the building designs used on the site. Loading, service, common refuse (such as dumpsters) and storage areas are not shown on the site plan set, nor is mechanical equipment specified. Show proposed loading, service, refuse, and storage areas as well as mechanical equipment on the site plan set. If mechanical equipment is roof-mounted, provide roof plans. 18 The following should be located to eliminate visibility from the Entrance Corridor street. If, after appropriate siting, these features will still have a negative visual impact on the Entrance Corridor street, screening should be provided to eliminate visibility. a. Loading areas, b. Service areas, c. Refuse areas, d. Storage areas, e. Mechanical equipment, f. Above-ground utilities, and g. Chain link fence, barbed wire, razor wire, and similar security fencing devices. 21 The following note should be added to the site plan and the architectural plan: “Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated.” Note not provided on the site plan set; no architectural drawings have been submitted. Add the standard mechanical equipment note to the site plan set and architectural drawings. Lighting No lighting plan has been provided. Submit a lighting plan with photometric values for all freestanding and wall- mounted lights as well as a lighting schedule and cut sheets for review. Landscaping Although trees are shown on the layout plan, no landscape plan has been provided. Submit a landscape plan with plant schedule for review. 7 The requirements of the Guidelines regarding landscaping are intended to reflect the landscaping characteristic of many of the area’s significant historic sites which is characterized by large shade trees and lawns. Landscaping should promote visual order within the Entrance Corridor and help to integrate buildings into the existing environment of the corridor. A row of trees is shown along the EC frontage. Although landscape details are not complete, it appears that the large street trees are not spaced 35’ o.c. as required by the EC Guidelines. Overhead lines run along the frontage, as close as 10’ from the property line. These could conflict with the required street tree planting. Basin B is located as close as 15’ to the EC. Given this proximity, and the engineered Provide a quantity of large shade trees along the EC frontage equivalent to 35’ on center, free of utilities and easements. Create a denser vegetative cover along the EC frontage. Relocate the access road to the west side of Basin B. 8 Continuity within the Entrance Corridor should be obtained by planting different types of plant materials that share similar characteristics. Such common elements allow for more flexibility in the design of structures because common 9 landscape features will help to harmonize the appearance of development as seen from the street upon which the Corridor is centered. appearance of the facility, a denser tree buffer separating Basin B from the EC is appropriate. Better screening and integration would be achieved if small trees and shrubs were layered among the larger proposed trees, creating a denser screening effect. Planting smaller trees under the overhead utility line could forestall complications and the need to top trees in the future. The detention pond itself has been enlarged since the concept plan approved with ZMA- 2013-16. An access road has been added to the east side of the facility, and less landscaping is shown between the facility and the EC. The access road will not have an appropriate appearance for the EC. It would have less impact if located on the west side of the basin, and if landscaping were arranged to screen it and integrate it into the surroundings. A 3-board fence is proposed along the EC frontage, and the north and south sides of Basin B. The fence will not provide screening, but could contribute to the creation of an appropriate rural-character landscape/streetscape. A fence was approved as part of the landscape treatment of the Cascadia stormwater facility adjacent to the Rt. 20 EC [Figure 4]. That facility (which is much larger than Basin B) is in place, the landscaping and fence do not appear to be complete, and the facility is very visible from the EC. Provide landscaping to screen Basin B from the EC and integrate it into the surroundings. Revise the frontage planting to include small trees and shrubs layered among the large trees. 19 Screening devices should be compatible with the design of the buildings and surrounding natural vegetation and may consist of: a. Walls, b. Plantings, and c. Fencing. 20 Surface runoff structures and detention ponds should be designed to fit into the natural topography to avoid the need for screening. When visible from the Entrance Corridor street, these features must be fully integrated into the landscape. They should not have the appearance of engineered features. 32 Landscaping along the frontage of Entrance Corridor streets should include the following: a. Large shade trees should be planted parallel to the Entrance Corridor Street. Such trees should be at least 3½ inches caliper (measured 6 inches above the ground) and should be of a plant species common to the area. Such trees should be located at least every 35 feet on center. b. Flowering ornamental trees of a species common to the area should be interspersed among the trees required by the preceding paragraph. The ornamental trees need not alternate one for one with the large shade trees. They may be planted among the large shade trees in a less regular spacing pattern. c. In situations where appropriate, a three or four board fence or low stone wall, typical of the area, should align the frontage of the Entrance Corridor street. d. An area of sufficient width to accommodate the foregoing plantings and fencing should be reserved parallel to the Entrance Corridor street, and exclusive of road right-of-way and utility easements. 10 Figure 4: Stormwater Management Facility at Cascadia, as seen from Route 20 North, and Entrance Corridor. Photograph taken by H. McMahon, 10.26.17. 11 33 Landscaping along interior roads: a. Large trees should be planted parallel to all interior roads. Such trees should be at least 2½ inches caliper (measured six inches above the ground) and should be of a plant species common to the area. Such trees should be located at least every 40 feet on center. A note on sheet 1 of the site plan set states that “street trees shall be provided along the public streets 50’ o.c.” Trees along interior streets will have a significant impact on the view from the EC; consequently, the interior street trees should be planted 40’ o.c. to meet EC guidelines. Revise the spacing of street trees on interior streets within the development to 40’ o.c. 34 Landscaping along interior pedestrian ways: a. Medium trees should be planted parallel to all interior pedestrian ways. Such trees should be at least 2½ inches caliper (measured six inches above the ground) and should be of a species common to the area. Such trees should be located at least every 25 feet on center. Street trees are provided that serve to shade street parking spaces and sidewalks. None. 35 Landscaping of parking areas: a. Large trees should align the perimeter of parking areas, located 40 feet on center. Trees should be planted in the interior of parking areas at the rate of one tree for every 10 parking spaces provided and should be evenly distributed throughout the interior of the parking area. b. Trees required by the preceding paragraph should measure 2½ inches caliper (measured six inches above the ground); should be evenly spaced; and should be of a species common to the area. Such trees should be planted in planters or medians sufficiently large to maintain the health of the tree and shall be protected by curbing. c. Shrubs should be provided as necessary to minimize the parking area’s impact on Entrance Corridor streets. Shrubs should measure 24 inches in height. A ten-space parking area is proposed south of the clubhouse. One tree is provided on the interior and two on the perimeter. 36 Landscaping of buildings and other structures: a. Trees or other vegetation should be planted along the front of long buildings as necessary to soften the appearance of exterior walls. The spacing, size, and type of such trees or vegetation should be determined by the length, height, and blankness of such walls. b. Shrubs should be used to integrate the site, buildings, and other structures; dumpsters, accessory buildings and structures; “drive thru” windows; service areas; and signs. The street trees which line the development’s interior roads are placed within a 10’ landscaping and maintenance easement. Those trees that line the north and east parcel boundary lines, separating the development from the Kappa Sigma Headquarters property, however, seem to fall within individual lots and not within a similar 10’ landscaping easement. The Ensure that the tree buffers on the north and east parcel boundary lines are planted within a 10’ landscaping easement maintained by the HOA and not on private property. 12 Shrubs should measure at least 24 inches in height. easement is required to ensure retention and maintenance. 37 Plant species: a. Plant species required should be as approved by the Staff based upon but not limited to the Generic Landscape Plan Recommended Species List and Native Plants for Virginia Landscapes (Appendix D). A plant schedule is required with the landscape plan. Submit a landscape plan with plant schedule for review. 38 Plant health: The following note should be added to the landscape plan: “All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant.” Note not provided. Add the standard plant health note to the landscape plan. Site Development and layout Development pattern 39 The relationship of buildings and other structures to the Entrance Corridor street and to other development within the corridor should be as follows: a. An organized pattern of roads, service lanes, bike paths, and pedestrian walks should guide the layout of the site. b. In general, buildings fronting the Entrance Corridor street should be parallel to the street. Building groupings should be arranged to parallel the Entrance Corridor street. c. Provisions should be made for connections to adjacent pedestrian and vehicular circulation systems. d. Open spaces should be tied into surrounding areas to provide continuity within the Entrance Corridor. e. If significant natural features exist on the site (including creek valleys, steep slopes, significant trees or rock outcroppings), to the extent practical, then such natural features should be reflected in the site layout. If the provisions of Section 32.5.6.n of the Albemarle County Zoning Ordinance apply, then improvements required by that section should be located so as to maximize the use of existing features in screening such improvements from Entrance Corridor streets. f. The placement of structures on the site should respect existing views and vistas on and around the site. None of the proposed residential units front the EC, and none are parallel to the EC. Most have their sides or rear elevations turned to the EC, looking inward. The site plan exhibits an organized pattern of roads and pedestrian connections. Open spaces are reduced to one park space and two SWMFs. No notable natural features exist on the site, nor are viewsheds emphasized by the arrangement of housing. None. 13 Site Grading 40 Site grading should maintain the basic relationship of the site to surrounding conditions by limiting the use of retaining walls and by shaping the terrain through the use of smooth, rounded land forms that blend with the existing terrain. Steep cut or fill sections are generally unacceptable. Proposed contours on the grading plan shall be rounded with a ten foot minimum radius where they meet the adjacent condition. Final grading should achieve a natural, rather than engineered, appearance. Retaining walls 6 feet in height and taller, when necessary, shall be terraced and planted to blend with the landscape. Grading on the site is extensive. A 6’-tall segmented retaining wall is proposed west of Basin B, separating the open space from the rear of lots 77-81, as depicted on Sheet 5, Grading Plan. On Sheet 3, Layout Plan, two rows of trees/plantings are proposed between the retaining wall and Basin B. It appears that the proposed trees/plantings will conflict with the retaining wall. Even if fronted by landscaping, the wall will be visible, so the material and color of the retaining wall block is important. Provide plants at the top of the retaining wall west of Basin B. Coordinate sheets 3 and 5 regarding the retaining wall and proposed landscaping near Basin B. Indicate on the plan the proposed material and color for the retaining wall and submit a sample for review. 41 No grading, trenching, or tunneling should occur within the drip line of any trees or other existing features designated for preservation in the final Certificate of Appropriateness. Adequate tree protection fencing should be shown on, and coordinated throughout, the grading, landscaping and erosion and sediment control plans. 42 Areas designated for preservation in the final Certificate of Appropriateness should be clearly delineated and protected on the site prior to any grading activity on the site. This protection should remain in place until completion of the development of the site. 43 Preservation areas should be protected from storage or movement of heavy equipment within this area. 44 Natural drainage patterns (or to the extent required, new drainage patterns) should be incorporated into the finished site to the extent possible. 14 SUMMARY OF RECOMMENDATIONS Staff recommends the following as the primary points of discussion: 1. Visibility of the development from the EC; architectural drawings required for the next submittal. 2. Treatment of the stormwater facility Basin B adjacent to the EC. 3. Frontage landscape treatment Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee:  Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and recommended conditions of initial plan approval: 1. Prior to initial plan approval revise the landscaping in the vicinity of Basin B as follows: a. Provide a quantity of large shade trees along the EC frontage equivalent to 35’ on center, free of utilities and easements. b. Create a denser vegetative cover along the EC frontage. c. Relocate the access road to the west side of Basin B. d. Provide landscaping to screen Basin B from the EC and integrate it into the surroundings. e. Revise the frontage planting to include small trees and shrubs layered among the large trees. 2. A Certificate of Appropriateness is required prior to final site plan approval.  Regarding recommendations on the plan as it relates to the guidelines: 1. Consider layering the landscape buffer with a mix of large, medium, and small trees as well as shrubs to create a thicket. 2. Consider enlarging the open space area (0.69 acres) in order to accommodate all requested revisions.  Regarding the final plan submittal: 1. A Certificate of Appropriateness is required prior to final site plan approval. 2. Submit architectural elevations and floor plans for review. 3. Submit at least four sight-line analyses taken from various points on Route 20 to verify visibility of the development from the EC.. 4. Add the standard window glass note to the architectural drawings, Visible light transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%. Provide manufacturer’s specifications for the window glass. 5. Show proposed loading, service, refuse, and storage areas as well as mechanical equipment on the site plan set. If mechanical equipment is roof-mounted, provide roof plans. 6. Add the standard mechanical equipment note to the site plan set and architectural drawings, Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 7. Submit a lighting plan with photometric values for all free-standing and wall-mounted lights as well as a lighting schedule and cut sheets for review. 8. Provide a quantity of large shade trees along the EC frontage equivalent to 35’ on center, free of utilities and easements. 9. Create a denser vegetative cover along the EC frontage. 10. Relocate the access road to the west side of Basin B. 11. Provide landscaping to screen Basin B from the EC and integrate it into the surroundings. 12. Revise the frontage planting to include small trees and shrubs layered among the large trees. 15 13. Submit a landscape plan with plant schedule for review. 14. Revise the spacing of street trees on interior streets within the development to 40’ o.c. 15. Ensure that the tree buffers on the north and east parcel boundary lines are planted within a 10’ landscaping easement maintained by the HOA and not on private property. 16. Add the standard plant health note to the landscape plan, All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant. 17. Provide plants at the top of the retaining wall west of Basin B. 18. Coordinate sheets 3 and 5 regarding the retaining wall and proposed landscaping near Basin B. 19. Indicate on the plan the proposed material and color for the retaining wall and submit a sample for review.  Regarding conditions to be satisfied prior to issuance of a grading permit: None. TABLE A This report is based on the following submittal items: Sheet # Drawing Name Drawing Date/Revision Date 1 Cover Sheet 9/5/17 2 Existing Conditions 9/5/17 3 Layout Plan 9/5/17 4 Utility Plan 9/5/17 5 Grading Plan 9/5/17 7 Stormwater Management Plan 9/5/17