Loading...
HomeMy WebLinkAboutARB201600141 Application 2016-11-07 ^yu*^i.,,. Community Development Deparima it 'S I ?,. Albemarle Co% 4 ire Road Charlottesville,VA22902-4596 J t e:(434)296.5832 Fax:(434)972-4126 , . I•.t Planning Application YaW PARCEL/ OWNER INFORMATION TMP 06100-00-00-12300 Owner(s): RIO ASSOCIATES LIMITED PARTNERSHIP C/O DUMBARTON PP Application# ARB201600141 PROPERTY INFORMATION Legal Description I ACREAGE - ALBEMARLE SQUARE }^ Ir Magisterial Dist.I Rio iv': Land Use Primary,Commercial Imo' Current AFD Not in A/F District Current Zoning Primary Planned Development Shopping Center APPLICATION INFORMATION Street Address 55 ALBEMARLE SQ CHARLOTTESVILLE,22901 Entered By nnifer Smith El Application Type Architectural Review Board 17i 11 4 2016 I Project TFYAS ROADHOUSE-SIGN Received Date 11/03/16 Received Date Final Submittal Date 11/07/16 Total Fees Closing File Date Submittal Date Final Total Paid Revision Plumber Comments 'A . h �i Legal Ad - I^I SUB APPLICATION(s) Type 'Sub Applicatio ' Comment SIGN 11/07/16 ' APPLICANT /CONTACT INFORMATION ContactType Name Address CityState -- Zip - Phone PhoneCell Ormer/AppG-ant RIO ASSOCIATES UNITED PARTNERSHIP I P 0 BOX 9462 I.RICHMOND VA 2322E . _._...._.........._._..____..._ -:--......._....._.._______..__..._..�-.__..._._.__...�_._...._.._ _.._--_._......._ .._a Primary Contatt DOUG STENLER- HIGHTECH SIGNS 2165 SEI•IINOLETRAIL i CHARLOTTESVILL 122901 4349747900 Signature of Contractor or Authorized Agent Date 1 • Application and Checklist for Sign Permit Part A: Applicant and Parcel Information Texas Roadhouse 455 Albemarle Square,Charlottesville, VA 22901 Project Name: Address: Tax map and parcel(s): 06100-00-00-12300 Zoning: PDSC Contact Person(Who should we calUwrite concerning this project?): Doug Stemler /Hightech Sighs Address 2165 Seminole Trail City Charlottesville State VA Zip 22901 Daytime Phone(434) 974-7900 Fax#(434) 974-6898 E-mail dougs@htsva.com Owner of Record: Rio Associates Limited Partnership do Dumbarton Properties Inc Address PO Box 9462 City Richmond state VA zip 23228 Daytime Phone( ) Fax#( ) E-mail Contractor Name/Business Name: Hightech Signs Address 2165 Seminole Trail City Charlottesville State VA Zip 22901 Daytime Phone(434) 974-7900 Fax#(434) 974-6898 E-mail dougs@htsva.com Part B: Determining application requirements and fees 1. Sign Permit—Please indicate which sign type you are applying for: ❑ Freestanding or Monument Sign: $91.64 ❑ If a footing is required,an additional fee is required: $32.64 ® Wall Sign(Including property,awning,fuel pump canopy signs): $91.64 El Sign Refacing: $59.00 2. Electrical Permit— Will the sign be illuminated? [i Yes (Illuminated signs require an electrical permit and an electrical schematic.) $48.96 El No $ 0.00 3. ARB Review— Will the permanent sign(s)be constructed in an Entrance Corridor? (See the Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors.) ❑ Yes (This sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $129.00 Comprehensive Sign Review. See ARB requirements next pages) • Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee Comprehensive Sign Review. See ARB requirements next pages.) ❑ No (This sign will not be constructed in an Entrance Corridor) $0.00 FEE TOTAL(Please add all the amounts checked in sectionsti 1—3): �]r� $ itl b.60 FOR OFFICE USE ONLY BP# ` ( - a 2 J . ARB# &tj Fee Amount S 1110.lY D Date Paid By who? Receipt#tkalltheck# By County of marle Department o unity Development 401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434) 972-4126 11/1/2015 Page 1 of S M Part C: Submittal Items Required Note: Submittal packages must contain 4 collated copies of all information unless otherwise indicated. Additional submittal materials may be required if review by the Architectural Review Board is necessary. Applicants will be notified if additional materials or ARB review are required. SECTION 1: FREESTANDING, SUBDIVISION OR DIRECTORY SIGNS A. Submittal Requirements ❑ Site plan or latest approved plat showing,to scale,the proposed location of the sign(s)with dimensions. ❑ Distance from the sign to the property lines and/or edge of the VDOT right-of-way. ❑ A footing/foundation diagram showing how the base or pole will be anchored in the ground. ❑ If the sign will be located in an easement,a letter of approval from the easement holder will be required. ❑ A to-scale color illustration of the proposed sign showing ❑ Dimensions of the sign,including overall height from the ground;cabinet size, length,width and depth;base size,etc. (Be sure to also include these dimensions on the diagrams provided in the Sign Permit Application packet.) ❑ Proposed lettering and/or graphics in their proposed location. ❑ Entrance Corridor Requirements:If the sign is to be constructed in an Entrance Corridor,also provide a color illustration of the front and side elevations of the sign showing: o If internally illuminated,indicate which areas of the sign are opaque and which are illuminated.Internally illuminated cabinet signs must have opaque backgrounds. (Opaque materials don't allow light to pass through. When lit only from behind,the color of an opaque material cannot be detected nor can objects be seen through it.) o Identification of proposed materials and colors.Include standard color id numbers(Pantone,Benjamin Moore, Acrylic,etc.)for all materials,text,graphics,base,faces,trim caps,returns,etc. o Provide accurate physical samples of all colors proposed,preferably in the material proposed.(Paint chips that accurately reflect the proposed colors are acceptable.) o Provide a site plan showing proposed landscaping around the sign,including botanical names and planting sizes. o Additional submittal materials may be required if review by the Architectural Review Board is necessary.(The applicant will be notified if this requirement applies.) B. Inspection Requirements for Freestanding, Subdivision or Directory Signs ❑ Applicant must mark the location of the property lines and the location of the sign with stakes in preparation for a preliminary zoning inspection. (All four corners of the sign must be marked with stakes that are easily visible to all inspectors.) ❑ A preliminary zoning inspection must be completed to verify the location of the sign before the permit can be issued. ❑ Freestanding signs are required to have footing inspections.(scheduled by applicant) ❑ Freestanding signs are required to have electrical inspections if illuminated.(scheduled by applicant) ❑ Freestanding signs are required to have final building and zoning inspections.(scheduled by applicant) 11/1/2015 Page 2 of 4 S M SECTION 2: WALL SIGNS A. Submittal Requirements ® A drawing,to scale,showing dimensions of the sign(length,height,depth). ® Elevation drawing(s)or modified photograph of the entire building,to scale and in color,showing The sign location on the building,sign height above grade,and the length of building frontage.(Be sure to also include these dimensions on the diagrams provided in Appendix B.) ® Sign lettering and/or graphics in their proposed location. ►1 Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color illustration of the front and side elevations of the sign showing: o Indication of sign type(channel letters,cabinet,panel,etc.). o Indicate on the drawings the proposed materials and colors.Include standard color identification numbers (Pantone,Benjamin Moore,Acrylic,etc.)for all materials,text,graphics,faces,trim caps,etc.For channel letter signs,indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is attached. o Provide accurate physical samples of all colors proposed in the sign,preferably in the material proposed.(Paint chips that accurately reflect the proposed colors are acceptable.) o Location of proposed light fixtures and manufacturer cut sheets describing illumination type,intensity,style, shielding,color,and height.All lighting must meet ordinance requirements as outlined in Section 4.17. o For internally illuminated signs,indicate which areas of the sign are opaque and which are illuminated.(Opaque materials don't allow light to pass through. When lit only from behind,the color of an opaque material cannot be detected nor can objects be seen through it. Internally illuminated cabinets must have opaque backgrounds.) • B. Inspection Requirements for Wall or Projecting Signs ▪ Wall and projecting signs are required to have electrical inspections if illuminated. (Scheduled by applicant) ❑ Wall and projecting signs are required to have final building and zoning inspections. (Scheduled by applicant) SECTION 3: ILLUMINATION REQUIREMENTS A. If the proposed sign is to be illuminated,the applicant must provide the following: ® Electrical permit ® Electrical schematic ❑ The location of proposed light fixtures identified on a plan and/or elevation ® Manufacturer cut sheets describing illumination type,intensity,style,shielding,color,and height.All lighting must meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance. SECTION 4:WORK VALUATION 11/1/2015 Page 3 of 4 41111 A. Work Valuation $ 4060.00 Part D: Applicant Agreement Applicant must read and sign • Each application package must contain 4 folded copies of all plans and documents being submitted. Only 1 set of material/color samples is required. All submittal items become the property of Albemarle County. Applicants are encouraged to maintain duplicate copies in their own files. • The application package is not complete without this checklist,completed,signed,and included with the required submittal materials indicated on the checklist. I hereby certify that the information provided on this application and accompanying information is accurate,true and correct to the best of my knowledge and belief and contains all information required by these checklists 10/25/16 Signature of person completing checklist Date Doug Stemler /Project Manager 434-974-7900 x105 Printed Name/Title Daytime phone number of Signatory County of Albemarle Department of Community Development 401 McIntire Road,North Wing,Charlottesville,VA 22902-4596 (434)296-5832 Tel,(434)972-4126 Fax www.albemarle.org 11/1/2015 Page 4 of 4 x I r , r�1s -� - -' - -_- _ — 1 I ____ oa S -_ _ f7x M N719e I l I I — --- - - _ _.___v~ -�_ -_�_ \ -- _ -- --r tor...r.oe os+oa 1,-1 T.,.© ' rrQ mi � i Q Q ii + -�__-� QI IritTe-71 1°.; . - ...- x l _ 4 A,..-4-,- ,Arsm•molg,',041r - 'I.. .• si — -- NC t p.; „WITIk, -14 Ei • qt I w ..ItIL -- ,,,,,,,,.(W1 1 1 -ap A 0 5,t o 0-/ 'Ai ® i F e r. AP'") CD f:;� o l II„` � l ©. I 0�" o©o In , a I p c, k1r J I.E. II . Ic:' ✓ �%, r1 I 1 ' --' l '` TEXAS Igo ©{''_i SIGN C: ..m— ROADHOUSE ;p ® '- �_ SIGN A: MI • t.:ao ;s,� 0ri oo .Ew.=488.50 ( o • '—. ' '. 0 I alD J L.--4-_-�-- , e I l i •' ;ii 0 • 111— II 1 . > N. h I .11 4T-------1--- I- = = -� w- ---==nor-�" --e '�`�s� , d> is T $EMINOLE TRAIL SITE PLAN/SIGN PLACEMENT 11 > . Rt:9111I15SM-Revised elevations and reduced Sign A by 10.75% pyO I This original drawing FEDERAL ManufacturingFecamer RandyCearlockpO"�tl as part°r a Oceanswe-a - F nrxlfe-Columbus �;12/7l15SM-Reduced Sign A by 8.6%,total 19.35%from Account ReP' .10b Number: 23-30578-10 planned project HEATH Onamde-Las Oolded5•Lx,g la+-4ang Fah on9mal dealpn. and a not to tx exh bhetl. w9 R3:t/20/16SM-Revised elevations S. Maeser T MARCH 13,2015 awes-�acksornaVe-:-+ousLnn.san nrrorno rro�ecc Manage: Dacc. :opted or reproduce0 Copes Chron-o:econ-MrWa-ame R4:3I10116-SM-Removed Border LED and changed Acrylic faces to#2793. without the written SIGN COMPANY [tlorocok-1.c4J1Svfe-indanapol.s-c°iu"arus Cokes D p..,e Teo eeMennS May NotMalceAe.M gnarled Manerie.s.Rehr To Peepa%W n,m,n.:DOWMeen, S. Maeser 1 O, 9 permission or www.FecieralHeath.com r-ra"-wes:er-Ale-Knoamt•'bnlca Dtav rl By' s^er-rcur-:e•� An:- --er-=a-Cake eca^-W,rxcr ear. Client val/Date: ,.c- K-o SEMINOESVILLLE L Federal Heath Sign 160 W.Carmel Drive,Suite 236 Carrel,IN 46032 U I ^^""/ n c usr.a e..rox.ri,,.o CHARLOTTESVILLE,VA Company. LLC Or rt5 13171501.7790 Fax 1317lse1.7703 Building Quality slgnage Since 1901 LandlordApprovavDate: Otaee.oMM.ine.0 - aLL� ,ram �7esry^.v,..rer. 23-3U578-10R4 aunorioedagerlLosme 00( M1,3 — SU6MI171,E t 1 i t,. 1 ii,, 29'-:i SIGN TYPE() LOGO OA.H.-TEXAS, - . O N LO N -_ ON CO 0 0 I/ ill 0 11 i ii i C\I 1.1") 0 II i _.1. 0 • oil _ T , „ 93'-0" a FRONT ELEVATION-WEST SCALE:3/37=1-0. ..e, . ,... n linerfami,.....____ __ _____ , B law N ® =TEXASa, N i ip II 11 I ii LEFT ELEVATION-NORTH r 87_6 --► SCALE:3/3r=I.-Cr flEATH � RMsnns: Rt:9J11I15SM Revised elevations and reduced Si nAb 10.75% This original drawing Manulactunng FacAiues:I 1 9 Y ROjecL/Location: 6 plosided as part of a Oceanside-Ewess-lahwrMlie-CaumAusR2:12/7l15SM-Reduced Si nAb 8.6'%,total19.35%from ,xm„ntpep: RandyCearlock / .'obNumber. 23-30578-10 _ 9 Y planned project cearslde-las IrYegas-Lau9N,n-laano rags orginal desl n. and is not to beeinarea.R3:1129116 M Revised elevations. S. Maeser MARCH 13,2015 d or reproduces eweC-. r- --Hfton- -San see project Manager: t7acc: copied Coro.cmm�-G:atton-MlhvauKee R4:3/10716-SM-Removed Border LED and changed Acrylic faces to#2793. without the written SIGN COMPANY ''''""t-L''''e-Indlmacas-cckm' c....o.pcemr This&NMnSM i,AkkMa:CAmer Fnsne0Materia.,Rev To ROOvcl Samples Par D.:Coto,WW1 S. Maeser EMIN permission o f www.FederalHeath.com _r- esre'`"M- -Unica „awn Sheet Number: 2 9 Ara"= '-�>TOrra ecaar-wmra Face Client SEMINOLE TRAIL Federal Heath Sign /1pprovaVDate: w,y„,�1i� umacAr,o uM u.,. CHARLOTTESVILLE,VA 160 W.Carmel Drive,Suite 236 Carmel,IN 46032 n C um.carraaaNra Ae Company, LLC O:' rt5 13171 581.729D Fax(3173 581.7783 Building ouautySignage srnce 1901 LandlordApprovaVDate: O i1d*al� 31VLA1Pe"""a�"'"""m' Design 23-30578-10R4 aurhorized agent®mbe i CJ (V CV RIGHT ELEVATION-SOUTH --- - 87'-6" , SCALE:332•=1'A' .1 0 C, i 1. E r ig_ li REAR ELEVATION-EAST SCALE:332-=I'S- ri FEDERAL R1:9/11/15SM-Revised elevations and reducedSi Sign10.75% This original Manufacturer;Poonrles: 9 by °ro;ec:;Baca:or. drawing Oceania-EWess-Jadssonde-Caumous R2.12/7/15SM-ReducedSi Sign 8.6%,total19.35%from Acw�mtRep. RandyCearlock rs presided as part of a HEATH oVee�a . 9 Y Joe WumDP 23-30578-10 planned project OCeansitle-Las lhgas-Lalgnrrt•ldMO FaNs R3:i/21d,58-SM-Revised elevations. S. Masser 'r` MARCH 13,2015 arid is not to be exhibited, Euless-Jacrsoriioe-:iouslon-San Antonio P•oeC.Manager' Datc. copied or reproduced Corpus Christi-Craton•talwaukee R4:3/10/16-SM-Removed Border LED and changed Acrylic faces to 82793. p11 without the written SIGN COMPANY Yisvoroo -Lo ap-ineldnapols-CalumCu! ^o�sDep[teaInmase,aeringMayNotMa:U.KwaenafIutuxelas.RekripnnsxisM,pesFarexac:cai Mxtn S. Maeser d 3 ar 9 permission o I www.FederalHeath.corn Gnomes-WesterMk-xno,MIe•TunedSEMINOLE Drawn 9y' SreetNw^�e•: Marna-Tampa-Oajtora 9cacr-•,Vin;;r Part Client Approval/Date. U nrrlbn - CHAR OTTESVILLEL VA Federal Meath Sign 160 W.Carmel DNNl,Suite 236 Car/11N,IN 96032 n o ' Company, LLC Or its 1317)581.7790 Pax(317)se1.7703 Building ouaaty signage since 1901 Landbrn O L.eo,.mn.Ine. .Y.....ra�,..�r°�r,o.� 23-30578-10R4/1(�IOVaI/Ddte: Destg^.V...-^:�r. authorized agent e zoos • 1. The level of illumination provided by the LED lights will not exceed the illumination 1 produced by a single stroke of 30 milliamp (ma) neon." I ; - - Area-el 2:48"x 45 5 I !Avila. I Area 3:37 x 151"= 38.7 r 1 i -- — — S.— i 1 -Area 1:32"x 138"=30.6 L` LOGO I2' 8" - - -i- - - rti - r "TEXAS" i ' I . b it,l U I 84.3 SQ.FT. TOTAL Pi I NOTE: ACRYLIC FACES #2793 col Individual Plex Faced LED Illuminated Channel Letters- ONE (1) Set Req'd. 'Cij _:, SIGN TYPE CO , - Sealant Along TOP and SIDES ss ndary penetrations 5 / Scale:KITS / PMS 18 loss Red Aluminum SCOPE OF WORK: SCALE:3/8'=1'-0` S ,;. y Letter rnswll'Red Retainers Manufacture and install Plex Faced,LED Illuminated channel letters having remote power supplies located Transformer Box Mounted with Lid on Top r s1� Rust Resistant#10 Self Tapping Screws. in accessible area behind wall. ;1 If wall conditions are not conducive to 120 VAC/12VDC Power Supply Self Tapping Screws mounting,ALTERNATE (Mount In Transformer Box) MOUNTING METHODS will be needed. 14 AWL Wire From Power Supply #2793 AcryliC" s INSTALLER IS RESPONSIBLE FOR: ELECTRICAL REQUIREMENTS To LEO connector Inside--. �� • Faa PROVIDING AND INSTAWNG ALL COMPONENTS REQUIRED TO RUN ALL BRANCH CIRCUITS SHALL BE Each Letter. Match P 185 SECONDARY WIRING(CONNECTORS,Gf0 CONDUIT,ETC.)TO BE Total: 6 Amps DEDICATED TO SIGNS(INCLUDING Transformer Box Mounting Brackets by Installer -7, DETERMINED BY LOCAL CODE AND SITE CONDITIONS. GROUND AND NEUTRAL)AND Metallic Seal-Tde In Wall For Supply -- - i t< Channel LED Gen s SHALL NOT BE SHARED WITH and Primary Leads �� Red LED Lighting in Letters PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMNED IWhite LED Grid Lighting in Logo. BY LOCAL CODE ANO SITE CONDITIONS. (1 )120V 20A Circuit Required. OTHER LOADS. ; J-Box(By Others) 1 063 Aluminum Letter Backs e l MATERIAL FINISH COLORS C.:.�:►;�r PMS 1e0 t't1�3 Rep +Ap2B M.tr naY Gees elekn 2200.15 250?22 It IF Gbea R . r,...' sea I_.�c vest.N'lylc PMS Wnb ■V nN a,ca-pc b Pa15.17I Vabw VinN ■Biau V nN I. Rec.c,•. nco.aa mvn.o..v,nc. %•Drain Holes In Letter Bottom Maim 'ted INN&State' I WnneA ric race b,31.to Matta PMS Lew,q Wnte Oun-e. Wma aeeNie Leay.plear Del.. ' :% (2 Minimum) WHITE Mali PMS`.baG Make PM5 122 Make PMS:4 . ! Letter Returns Letter Face Letter Trim Cap Logo:Per. Logo:'State"Return. Loge:-state" Logo:"Hat"Return& Logo:"Her Logo:"ear �o ,I a Retainer. Retainer i i CUSTOMER TO PROVIDE: H ALL BPAN4'"AWRY atetAcu.PtRYCE)CRCIAts ereeImoecit0N to EACH o liwnrersRl10 sf IN CERSRED fLECIRCRN: aatae oCeuai atermetoramw t ors Mapromos* we art rolsnmdllore Arad dOn.one.each Oty.Sr test Kn.... H..ii-,;e ..�. 1e eswlninaS¢S m Sr conned m a,aitenanc canning deece nun anal Energy la ap-re[5t9n5,1me Clock orPhoM Cre mat A s beech carats raIs tio t resle[m aminesdenex as Ittp n pair dto%eSmart waat'MIS...d*name meat po cro4. Vat Garr Ir 0NtAn to sate a seen el ens.eat,eats FatMea m suet cause damp to me ennui components of M son and ———— r ' eee�e i Plop deAu made eat a stares re pnc pal soon r talker.ate l score co re p-aad tter cpdopea. C.Properly aid nod an matcan0nrendDeckleme Sean SMMeklit OeMoe6d. WI eatery. D.mrreerlN seed scuts le WI sgmmMrn Fedora tram Pais requirement o Sarre dnerav Reeks regatm aroary tact Cr narcat concerns.cam 4ue.My dmmkg tme spa eaMus tonSeram LED LOW VOLTAGE LIGHTING SYSTEM AM Miatbn tom me gore ecomlenOtOons may maul le edl Fella Heath Sign Co.•e rod me waning. t.wuepeton0npo0tdperam0Penip(sl. U.L.RECOGNIZED-CLASS 2-CONFORMS TO U.L.48 2.Delays and addoeta costs. FEDERAL Meru igAdcRA' remake R1 9111l15-SM•Revsedelevatonsand reduced Sig Aby1075' °^ce':!Lxa,c^ This original crewing rI Oceanme-Euless-ladtsorMR-Cdumbus R2:12/7/15-SM-Reduced Sign A b y B 6%.total 19.35'•t from Kccun:Rep, RandyCearlock Is prodded as PIT of a yeetiu cat 23-30578-10 p'anned project HEATH OVegs-Lau a: original desiggn. axanot to tx SdimRed Oceanabe•tas vtgae•Lxggrl•lddho Fes R3'1/20/16-Set-Revised elevations S. MaeseT MARCH 13,2015 Euless-ladcsannge-Houston-San MMO P'OeQ,Manage:' Datt'. :Cpied or /eA'oduced Corpus Chem•Graten-MQnMaaxe R4:3/10/16-SM-Removed Border LED and changed Acrylic faces to#2793. wl'nout [he written SIGN COMPANY wine mans-iouone•IndlarMpoas- *"." Co Orocteommax. rnq Wry No.MA:-,..-a F-5-r,vat e.a: ee:e• ::---ce:r•e-a. ",++.. *r` 4 c 9 o e r m N s s I 0 r of wvw.FederalHeath.coma -nor nal''• erwee- •n'1e Dream ey S. Maeser Snee;roun•cec a,rxa-Tar^pa-Daytona Bcach•Winta atom Client SEMINOLE TRAIL Federal Reath Sign ayoprovaVDate: andennnws CHARLOTTESVILLE,VA 160 W.Camel Delve,Berme 236 Carmel,IN 46032 U n c Co:'npdny, L: Or its CLaboramd..lnc aML.ear..'Lace>.ete DesgnNumber. 23-30578-10R4 (3171 5e1•7790 Fit(3IT)Sei•77e3 Butitllsty oualnystgnspe since 1901 andlordApplwaVDate: a.rnoriud age.'+:omae 18.1 SOFT. 5'-7 Fabricated Aluminum Cabinet Filler --- 11 10" and Routed Face to be painted PMS 6c Satin Black. \ I I__ 3/8'Galvanized Mounting Nuts Welded LOGO:Circle Section to be Route. .t. Backed with White Acrylic(PMS White)) r Inside of Cabinet(By Federal Heath). Ihaving Vi • olor `te•ed to Face Surface.Bkgd is 2500-43 '' */' Light Tomato Re• (PMS 186) 3/8"Galvanized All-Thread 2500 15 Yellow Border(PMS 122). Rod With Steel Angle or 1'-5" - Wood Blocking or Installer). Appropriately Sized LOGO1,4 ' - LOGO:STATE shape is 2500-76 Holly Green Vinyl(PMS 554)and HAT is 2500-22 Black Vinyl IPMS 6C, Uni-Strut(By Installer). both having an Accent Border and Inside Lines being 2500-15 Yellow Vinyl(PMS 122). MIMI Electrical Feed Centered Vertically and Horizontally at Back of Cabinet. co TEXAS ROADHOUSE copy to be Routed Out of Face and Backed with White Acrylic IPMS White). -. > R 2S cri 0 T 1 r �J-Box By Others _ TExAs Stripes to be Routed Out and Backed with White.A rylic(PMS White)w/2500-43 > ROADHOUSE Light Tomato Red Vinyl Outline:(PMS 186j Oft First Surface of Acrylic Face. O' 5r,rRn \ �, Internally Illuminated w/800 MA Cool White Fluorescent Lamps. Single Face Illuminated Wall Sign One (1) Req'd DL.TYPE° Scale:3/4"= 1'-0" SCOPE OF WORK: Typical Cabinet End View Manufacture and install S/F Internally illuminated wall sign. PART#TRI8WSR CUSTOMER TO PROVIDE: • MATERIAL FINISH COLORS (For New'Remodel ConSmlcrice)ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL INSTALLER IS RESPONSIBLE FOR: SIGNAGE.CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS To BUILDING SITE CONTACT PROVIDING AND INSTALLING ALL COMPONENTS REQ'.,IRED TO RUN SECONDARY WRING(CONNECTORS.GTO CONDUIT. SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALLATION. ETC.)TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS. PMS Ec n2n 215C-43 ine Seth Buck worn n:;ryur: II Torrom Vinyl ALL BWNCn?R rafts'Er wens u SERVICE)CIRCUITS&RNA/suns ercIA CONNECTION TO pr urcSIGNand DF9N s FT)TO BE r rag). ELECTRICIAN: PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMNED BY LOCAL CODE AND SITE CONDITIONS. PMS°"''"l'" Red�A^N A.Al,Oath crafts!or wens muss oe tersely dearard to signs prc�dnq cedicaltl grarc and dedicaed neat per crag). B.Sr ar ums mug nd beckoned err Arer bads such as lighting,err dondie Dal and oiler equipment PMS deft C.Property sired grand wire teal can be laced bast tore breaker pare)mull be pmeded. SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE PENETRATION @ EXTERIOR LOCATIONS_ Baca Bkgd Copy.Logo and sae.. Logo lop u a.and 0.N•mberand sze a ceculs In each sqn to met Feder,Hear Sips requremere. .0 area area sa..hper. My heir tames Woe recammeaaiors may resat nn I.Danaje to or/nava corneal a lee ep(s). ELECTRICAL REQUIREMENTS 2.Ddrys an Malone easel ALL BRANCH CIRCUITS SHALL BE Rolm 0Cerlaneectca component d wore 41MpenAZNYd5Psre not shut-off lorapaiodalme,we,um,day For best pedarmace. • DEDICATED TO SIGNS{INCLUDING 25C0-'E 2500-IS 25oc-22 pad p (i •tidy Green Ye low VYyI Black vinyl elements • we recarrnerq signs to be corroded b:t atomic coat re Oleo wick as at Enarpy elanaperner/Syslem,Tme Clock aPMb Cee tea Total: 3.4 Amps ail almakarysM IlresignforapenodaImteachday.FelonlodosowitcausedamagetoillelecicacomponentsAresignand GROUND AND NEUTRAL)AND SHALL Vinyl PMS 122 .AppaedtoYellowRegd. WI red re wanly NOT BE SHARED WITH OTHER WADS. pm 554c PMS 60 0 Some a dams aim sign comported,=singblot Arydmmng a Be sign rnradconstabon Logo:reer w;lh Federal neat So Co.rF rod Be warranty. ,a,..�sr,y. Logo: d ws.ews (J 120V 20A Circuit Required. rI FEDE�� - rtens c^s. R'.:9`1115 SP1-Re ee,--a r r.+,reduced Sign AbY''0.75`;., -ns a ^a a•awn- �^ RandyCearlock a pros idea as as o'a « R2:1217/15-SM R d;u ced SrS. r A by U a, ,.;.a'!19 35}.from ACCc�^•t Rep' Jcc ti4 ce•• 23-30578-10 p'A rt e e 0 p c J e H EAT H LRm sae-as onginal des=ggn Vee-Hs-Hamer R3 1/20l16SM-Revised elevations rt a^d is nor to de x 'ea. Euless-Jadaonae-Hamer-snAaltado o'oe^Manager S. Maeser T Marc. MARCH 13,2015 coed or rep.o,.viceo cerpuschrisd-Gahm-Mrwcaae R4:3/10116-SM-Removed Border I ED and changed Acrylic faces to F279;. vv.:rou: the w''rre^ SIGN COMPANY er^�+wrook-Lwlsne-alalanapals-Columbs Canso tunInmis=loam: v v.v. ._n f s a v:e-a e _ .+..c4r Vie cn � f'" wwvr.Federal Heath.com Cvmonnad-V,tsreTMae-uNoku.e•it+au `➢ 7•av,n 5� S. Maeser Sreet�`yr„,_e.. p e' u 5 s o r u r Maria-Tampa-Da7mne leach•W M,.APR Client Approval/Date: _ SEMINOLE TRAIL 5 �` 9 FeC?'2 r'e21': $,^y 160 W.Carmel Drive,Surge 236 Carmel,MI 46032 0 ued.rwebr. A€C CHARLOTTESVILLE,VA C0^-teary. D.0 0' itS 1317)381.7790 Fax(317)581.7713 Sulkllng Quality Signage Slrice 1901 Landlord aVDate: /uga.rrr.Ina F` .w�� ..�>x oesgn Nt.rober. 23-30578-10 R4 AAP� a..rro•.zeo zger:. a 2006