ARB201600138 Review Comments 2017-02-02
Review Commen for SDP201600065 Minor Amendment Project Name: Crozet WTP Finished Water Pump Station - Minor Amendment Date Completed: Thursday, February 02. 2017 Department`Division/Agency: Review Status: Reviewer:`Margaret Maliszewski CDD APB Requested Changes A condition of approval required clarification on the plans that the light fixtures do not drop below the roof trim. Ceiling and eave heights noted on the lighting plan indicate that most of the fixture will hang below the eaves. The intent was to show that the structure would shield the non-full-cutoff fixture. If the structure does not allow for this, an alternative is to choose a full cutoff fixture. 1 Noisti Add screening to eliminate visibility of the generator and condensers. reAju,„4",„ 4,71C4.0 a-k S0444, it-4-V Cer- f; Move the transformer to eliminate visibility. 3. Revise the layout of the transformer screening shrubs to achieve a more natural appearance while �s�' maintaining screening.7-2_03,1,..41 ( , e;„c , a ' t--e4.4 G- = .,, ,, ( t_, ,, 4z (t,-', ..Ls / C: ' t.. CL mo.... + , y`•.e c, �.E Choose a screening plant for the transformer whose majure shape will continue to provide screening. /2",eyGG t. 7/ ,0 R:, ,, r, 'fi `eve locate the utility cabinets/meters to a side or rear wall. J/ � � v • ji..- gote on the plans the color of the equipment. 44" Add the standard mechanical equipment note to the plans. "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated." Q - - / 8. Clarify on the plans that the light fixtures do not drop below the roof trim. f° cam. 6"" v 4.-,.71,41,‘,. 1/1,-2.4.149 Add the standard lighting note to the plans. "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads.The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one half footcandle." ,, r Add three trees along the travelway, between the travelway and the northern property line, 21/4" caliper at planting. _. ..„4,` n. 0...44444. - cl"e. ac� -,.-, rt•t f '-4,e, 3 G„. z- ` 11. Add the standard plant health note to the plan. "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant." d etztt4 �j,,'"12. Revise the placement of the row of Serviceberries to help achieve a more natural appearance and to help reduce visibility of equipment on site. 3. Stagger the row of Leyland Cypress for a more natural appearance. z014.---4) .„,..--4....e_c,t 44/ 64.1,",- zer4, 4.4..,,-- , V 14. Increase the number of tree species used for screening and mix the species for a more natural appearance. re , 5t3 i 7 5. Consider coordinating equipment color with wall color. d,C-)11,-C,. 16. Supplement the wooded area with evergreen screening. /404A-4,060:? ) 3 6,1 v cfc c -- {... i i I 1 Margaret Maliszewski From: Miles Jensen <mjensen@sehinc.com> Sent: Thursday, February 02, 2017 5:09 PM To: Margaret Maliszewski Cc: Douglas March; Patricia Saternye Subject: Re: Crozet FWPS Margaret, Thank you for bringing this to our attention. The light fixture should not hang below the eave. Let me offer the following: • On Sheet 9 of 14, the ceiling height above the generator is at Elevation 643.83 (643'-10"). • The eave is set at Elevation 643.50 (643'-6"). • The light fixture dimension shown on the cut sheet on the right hand side of the drawing is 3.74 inches. (I see our note is 3.74, but in this case should be identified as inches and not confused with feet). • Since the thickness of the light fixture is less than the difference between the ceiling elevation and eave elevation, the lights mounted to the ceiling will not hang below the eave. I hope this helps. Thanks. Miles B. Jensen, PE I Principal Regional Practice Center Leader SEH Direct 651.490.2020 I Mobile 651.775.5031 3535 Vadnais Center Drivel St. Paul, MN 55110-5196 main 651.490.2000 I fax 651.490.2150 I toll free 800.325.2055 I www.sehinc.com From: Margaret Maliszewski<MMaliszewski@albemarle.org> To: Douglas March<dmarch@rivanna.org>,"mjensen@sehinc.com"<mjensen@sehinc.com> Cc: Patricia Saternye<psaternye©albemarle org> Date: 02/02/2017 03:46 PM Subject: Crozet FWPS Doug and Miles, I've reviewed the revised plans and I see just one outstanding issue.A condition of ARB approval required clarification on the plans that the light fixtures do not drop below the roof trim. Ceiling and eave heights noted on the lighting plan indicate that most of the fixture will hang below the eaves.The intent was to show that the structure would shield the non-full-cutoff fixtures. If the structure does not allow for this, an alternative is to choose a full cutoff fixture. If I'm misunderstanding something, please let me know. Thanks. Margaret 1