Loading...
HomeMy WebLinkAboutSDP201900022 Review Comments Minor Amendment 2019-05-22r� 'AL � IRGS?at� County of Albemarle Department of Community Development Memorandum To: Jonathan Showalter, Timmons Group From: Tori Kanellopoulos - Planner Division: Planning Services Date: May 17, 2019 Subject: SDP201900022 — Brownsville Elementary School — Minor Site Plan Amendment The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approve the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Planning (Tori Kanellopoulos) 1. [18-32.5.2 and 18-32.6.2] Contents of a site plan: setbacks, building height. Include in a note on Sheet 1 the setback and height requirements for the R-1 Zoning District (per 18- 4.19). 2. [18-32.5.2 and 18-32.6.2] Contents of a site plan: Owners and zoning of abutting parcels. Provide the owner(s) and zoning of abutting parcel TMP 56-15 as it is directly adjacent. 3. [18-32.5.2 and 18-32.6.2] Contents of a site plan: Utilities. Provide the deed book and page number for existing/approved utilities. Label is private or ACSA utilities. 4. [18-4.17] Lighting. Add a note to the site plan that "All luminaires over 3,000 lumens shall be full cutoff fixtures." 5. [18-4.17] Lighting. Show the footcandle spillovers closes to the property line to ensure that the half -foot candle requirement is met. 6. [18-4.17] Lighting. Include a note that the Light Loss Factor shall be one (1). Engineering (Matt Wentland) 1. No Objection: No VSMP needed, under 10,000sf. Inspections (Michael Dellinger) 1. If used in conjunction with the required means of egress lighting for exit discharge, verify compatibility with fixtures. Otherwise no objection. Fire/Rescue (Shawn Maddox) 1. Fire Rescue understands the buildings on site will not allow for a 20' clear travel way at one specific point and acknowledges the narrowest point in the travel way to be approximately 14' wide area. Please show on the plan the travel lane that will allow access from the sidewalk to the proposed structure. The travel way should be 20' of clear width and a minimum of 13'6" vertical clearance. Any basketball goals or other obstructions should be accounted for in this layout. ARB (Margaret Maliszewski) 1. Revise the Color Detail sheet to show the building color as Old Town Gray. 2. Revise the site plan to show landscaping added to screen the view of the building from the Entrance Corridor street. 3. Revise the site plan to include cut sheets for the proposed light fixtures. Light fixtures should be full cutoff fixtures. Revise the lighting note on sheet C3 to coordinate with the revised fixtures. ACSA (Richard Nelson) 1. PENDING