Loading...
HomeMy WebLinkAboutSDP201900006 Plan - Approved Major Amendment, Final Site Plan 2019-06-184q IN 10 ON IQ h6 9 14 1. Owner/Developer: The Covenant School 175 Hickory Street Charlottesville, Virginia 22902 434.220.7329 2. Landscape Architects: JJM Design P.O. Box 2137 Charlottesville, Virginia 22902 434.806.6694 3.Engineers: Woolley Engineering 220 East High Street Charlottesville, Virginia 22902 434.973.0045 4. Parcel Information: TMP 90-A, Parcel 2 "Parcel Al" n/f The Covenant School (25.93 acres) Current Use: Private School (Campus Grades 7-12) Deed Book 1755, Page 173; DB 505, Page 548 (Plot) Existing Zoning: R-2 Residential (approved Private School per Special Use Permit SP-99-54) Special Use Permit: SP 99-54 Airport Impact Area District Overlay Steep Slopes: Managed and Preserved Overlay Dam Break Inundation Zone 5. Specific Parcel Information: a. Minimum Building Setbacks: 50 ft. b. Minimum Parking Setback: 20 ft. c, Minimum Undisturbed Setback: 20 ft. d. The following waivers were granted by the planning commission May 30, 2000 Allow disturbance within the 20-foot buffer along Hickory Street and Cooperative parking for the athletic fields and school parking farther than 500'away from the athletic facilities. 6. Planned Land Use: The proposed new recreation area which is approximately 12,000 sf will provide multiple amenities to the school. 7. Maximum Building Height of Proposed New Structure: n/a 8, Maximum number of new employees: 0 9. Maximum square footage for building use: (90,000 sq. ft. approved with SP-99-54) Pre -Construction 59,067 sq. ft. Post -Construction 59,067 sq, ft. 10. Adjacent Properties: TMP 90A-4, n/f Southwood Charlottesville, LLC Deed Book 3375, p 63; DB 664, p 447 Plat; R-2 Current Use: Mobile Home Park TMP 76-53H, n/f Estate of Lorena H. McCann Deed Book 964, p 357 & 352; DB 446, p 467 Plat; R-2 Current Use: Residential TMP 76-53R, n/f Betty rindrick Gibson Deed Book 1915, p 701; DB 446, p 467 Plat; R-2 Current Use: Residential TMP 76-53Q, n/f William and Doris Hutchinson Deed Book 948, p 406; DB 446, p 467 Plat; R-2 Current Use: Residential TMP 76-53C, n/f Shone and Stacie Reed Deed Book 4517, p 345; R-2 Current Use: Residential TMP 76-53G, n/f William H. Bray Deed Book 4493, p 661; R-2 Current Use: Residential WATER PROTECTION ORDINANCE WP0201900006 SCOTTSVILLE MAGISTERIAL DISTRICT 10. Adjacent Properties: (continued) TMP 76-53J, n/f Sandra M. Morris Deed Book WBI 34, p 566; R-2 Current Use: Residential TMP 76-56D, n/f Jorah A. Lester Deed Book 4283, p 552; R-2 Current Use: Residential TMP 76-56B, 56G, 56H, n/f R.M. and Maudie Chisholm Deed Book 333, p 450,452 Plot, DB 350, p 295 Plot; R-2 Current Use: Residential TMP 90-A-OF-1, n/f Wellman and Joyce Nash Deed Book 363, p 327, DB 362, p 22 Plot; R-2 Current Use: Residential Hickory Street (Private) 50'Width Ingress/Egress Easement Hickory Street (Public) Variable Width Right of Way 11. Datum and Benchmark Reference a. Boundary, easements and plat data based on physical survey by Kirk Hughes & Associates, 220 East High Street, Charlottesville, Virginia, 22902; revised and dated June 29,2008. b. Topographic information provided by Kirk Hughes & Associates, surveyor. c. All elevations based on Benchmark: City Of Charlottesville Gis Station 111. (Disk 102.7 Northwest Of Centerline Of Exit Ramp Of 1-64 West And 32.5'Southeast Of Centerline Of Northbound Lane Of Route 631.) Elevation = 416.74' d. Vertical datum: N"D 88. e. Horizontal Datum: Virginia State Plane Coordinates South Zone NAD 83,1994, Based On City Of Charlottesville Gis Stations 110 And 111. 12. General Construction Notes: a. Prior to any construction within any existing public right-of-way, including connection to any existing road, a permit shall be obtained from the Virginia Department of Transportation (VDOT). This plan as drawn may not accurately reflect the requirements of the permit. Where any discrepancies occur the requirements of the permit shall govern. b. All materials and construction methods shall conform to current specifications and standards of VDOT unless otherwise noted. c. Erosion and siltation control measures shall be provided in accordance with the approved erosion control plan and shall be installed prior to any clearing, grading or other construction. d. All slopes and disturbed areas are to be fertilized, seeded and mulched. e. The maximum allowable slope is 2:1 (horizontal.vertical). Where reasonably obtainable, lesser slopes of 3:1 or better are to be achieved. f. Paved, rip -rap or stabilization mat lined ditch may be required when in the opinion of the County Engineer, or designee, it is deemed necessary in order to stabilize a drainage channel, g. All traffic control signs shall conform with the Virginia Manual for Uniform Traffic Control Devices. h. Unless otherwise noted all concrete pipe shall be reinforced concrete pipe - Class 111. L All excavation for underground pipe installation must comply with OSHA Standards for the Construction Industry (29 CFR Part 1926). 1. Retaining walls greater than 3 feet in height require a separate building permit. Walls exceeding 4 feet in height require a stamped engineered design in addition to the separate building permit. k. All water lines, sewer lines, and fire lines from the main structure must have a visual inspection performed by the building inspection depadmemnt. 13. General Water and Sewer Conditions a. Work shall be subject to inspection by Albemarle County Service Authority inspectors. The contractor Will be responsible for notifying the proper service authority officials at the start of work. b. The location of existing utilities across the line of the proposed work are not necessarily shown on the plans and where shown, are only approximately correct. The contractor shall on his own initiative locate all underground lines and structures as necessary. c. All materials and construction shall comply with general water construction specifications as adopted by the ACSA on January 15,1998. d. Datum for all elevations shown in National Geodetic Survey. e. The contractor shall be responsible for notifying "Miss Utility' (1 -800-552-7001). f. All water and sewer pipes shall have a minimum of 10 feet of separation and 3 feet of cover measured from the top of pipe, over the centerline of pipe. This includes all Fire hydrant lines, service laterals and water lines, etc. g. 20' Wide easements, centered on the pipeline and appurtenances shall be dedicated to the Albemarle Service Authority, except where the line is in a public road right-of-way. h, 3' min. separation required between waterline and storm sewer culverts or 6" separation when waterline is insulated. Use 1/2" thick therma-cel pipe insulation in 3x4'sheets as manufactured by nomaca, inc. or equal approved by albernarle county service authority. Insulation to extend 5' beyond centerline of culvert in both directions or 5' beyond ends of culvert when parallel. I. Touch read meters are being used by the Albemarle County Service Authority, to accommodate these meters, meter lids will require a 1-3/4" hole tapped into the center of the lid. Blind tops or plugs shall be provided to prevent debris from entering the box prior to meter installation. j. All water and sewer appurtenances are to be located outside of roadside ditches. k. Certification that 95% compaction is obtained shall be provided for all fill areas under water and sewer lines and appurtenances. This certification shall be signed by a professional geologist, The certification shall state the exact area that the certification applies to. I. Valves on deadend lines shall be rodded to provide adequate restraint for the valve during a future extension of the line. 14. Stormwater Management & Water Quality a. Stormwater management for the project is not required. See SDP 02-29 for confirmation of the stormwater management waiver. b. The runoff from the new recreation area Will be pretreafed using a gravel diaphragm prior to entering the existing biofilfer. 15. Parking Nio new parking is being proposed or shall be necessary with the current development, r 6�11 Albemarle Co. Dept. of Community Development - Current Development Division DATE Albemarle Co. Dept. of Community Development - Engineering DATE Alb2_marre County Division of Fire and Rescue DATE 7L, Albemarle �a'.­Dept. of o-6unity Development- Inspection Division E5ATE 6 li�011 �9,61ht" 01f Virginia Dep/6 ment of Transportation DATE Albemarle County Service Authority DATE Other DATE US. 64 (EXIT 120) OLD LYNCHBURG ROAD 7 V W lx, SOUTHW )OD J THE COVENANT SCHOOL 01 y Q. VICINITY MAP Scale: I"= 1000' M C1.0 Cover Sheet w C1.1 Minor Amendment Exhibit 0 C2.0 Existing Conditions Exhibit M C3.0 Site Demolition Plan M C4.0 Site Layout Plan M C5.0 Site Plan M C6.0 Stormwater Management Plan 0 C7.0 General Details R C8.0 Recreation Equipment Details IM L1.0 Landscape Plan EM L2.0 Landscape Details E0 51.0 Structural Details 0 52.0 Structural Details Cont. M ES 1.0 Erosion & Sediment Control Narrative IM ES2.0 Erosion & Sediment Control Plan 0 ES3.0 Erosion & Sediment Control Details M Filled Box Indicates Drawing Included in Set TT M DESIGN LANDSCAPE ARCI-MICTUPP'. V�Q.Vvx 207 ChiflotlesvillL, VA _11902 Owner: The Covenant School 17' ' cko Street Ch2ottelle, Virginia 22902 P: (434) 220-7329 Job Number: 1851 Date: January 31, 2019 Revision: copyright 0 2019 by Woolley Engineering BOO T E'Y ]ENGINEERING �4` 3 Consulting Civil Engineers a 220 East High Street JFg a " Charlottesville a Virginia 22902 l" P 7 �-53 i d � r N/F JACMUEUNE K USSELL �ry ° ( ) 973.0045 M 1 P' J q w vv.Woolle Eg. coia� Y9 L,0, 391, Pg 596 PLAT fIMP ' •- ,60 I'MP 0.A--OF—I NIF R.M�.a & �;L DIE Cl-I"I IT��JIs?�1 N/F #I L �l a' I ftia i l _ 1 { 333, ` A�,O, .�a33, P ,x. PIAT � D3. 362, Pg 'fir PLAT ED 0. 35`?, Pg 295 I' $ r i IS'SP 7 Cp ""°n.de"1 i f'"y ` ,�`'°.^"', ��, s ,,✓ {. i ', 1 C€l7 Ylottts -Illt. Vf`i. 22902 ? I .81 3 0, Pig 293, 295 Plat ° 76-560 1 N/F BERi'iA.l D & sth"a,AlRMA YaE,RRaRILL .,�''�"�,. .. pp g q y y q p'•� i, I' • yi ;g "r' H /F R,M. '& ��a^4�,.�'p�_Iyz CIHiSH 7° qi P i j� P C L.+',C,�'3'L € Sf:tr3. �Y' E "`Y IN }y y 1 E���9 1 a'� M. p D.B 11 { ...V.; , f'� d� i ej d.w �-Kf i'S Rpy a[,py P%' t y �,. "�a"',,f'�,>�y+" � jP " 8 .".i y°'.w �brY�. a35f.JsPi. �k'i. YES, 3`jl r$ �JY aE�.. :,� ,r✓. ++"��y \ ��'yS9y+�955,i"7�'99 $9 jy` �a•� M' C� 6.%iYdG2. Owner: The Covenant School ggg{' w' p�� S p✓"'+ P' F DON % tt� LE BIi �'4i.�RS 'y. +'� .•$ 3 BICKERS MID � 3P t3 t3 0 (' 5 i , '., 2 ,88 { � ``°� ' Y ' :. ee i ,gypp ROGER R ID ,iqp, D ci.. g q �`'". ,PP LAC4 iha YR�V,%5:.9't BRIDGES .° tl:S.'3, �F�r.fi..3 ��� kL, I'"41.a"SI �,,.s,r �•a,.� 7�5ry p�� �`'av".a � 'h, x �" �^ 175 Hicko Street SDP 200900026 (Minor Site Plan Amendment): D.O. �A a ? -,m'� #•{ � ` o-,A� �. °•�a � .s D.B. #�•�, P� �1�F7 Per � � Charlottesville, Virginia 22902 J� Restoration of buffer previously disturbedIre P: (434) 220.7329 during the removal of the existing waste. PS ELIZABETH € THACKER F r' /F , O.B� 3j2r Pg 83, 90 PLAT' y t i D.& 541, Pa 257, 259 PLAT i'.0. 310, Pig 83 PLAT r�,P z �•J '"� � N/F FORE51 LODGE, LI j,- .•'°Ai �, a ` ✓� D. 3092, Pig 310 5, �� D.B. 3092, P9 316 PLAT a `76--53 ''� sp�7 T P 1 �' t " N/F � ILI { t DORIS `HUT i O SDP200$00091 (Minor Site Plan Amendment -Not Constructed: ° ce . �� �,�°� Replace existing sod football field with 100% permeable synthetic turf. D 446, PO 487 PI.X,,- �� ° � ' �� EX. BASEBALL FIELD . ����,° uajao TAX MAP 90A, PARCEL 2 Rs , ,'{ �, 25.933 ACRES � "PARCEL A1" __ THE COVENANT SCHOOL ��aJ� + =q D.B. 'TI ., P 7 _53P d "` s D.B. 1755, Pg 175 PLAT 03. 1915, P9 701 �! D.8, 445, Pg 467 PLATLL- Py 1 •g1�"•, a6o. ,,✓" $'� M ,J ,°Sy -a+-' �¢ee''' t .,»,=.TM+ „.v .MM^.a,. �. .:...-. .�O®�! �• ,...y ��r �.^""".✓ a� a�'�✓g° tl 'h0.�y ,,✓`,,�✓ 9 kI y�r ty� l y!J'�b.� 1: �J x R � EXHIBIT U"N''LY NOT FOR CONSTRUCTION 0 IRF THIS EXHIBIT ILLUSTRATES SDP20000044 PRELIMINARY & Uj p �° a #ah SDP200000 FINAL AND ALL SITE PLAN AMENDMENTS, TMP i I/F # O R�_Ikl�� ; t cf,'A qy Si$ D3 9634, Pq 35 0.8. Y�,',`li'. 441� Pig 46if .'F'"j1.3`Li MIT FOUND EX. FOOTBALL FIELD 1'7, ? `,}99 EX. ATHLETIC FIELD SITE PLAN COUNTY OVALKLIMARLE -,'l €{F_� iu �;tAa�y 64'Cit)� tll':.( .. • Final .:t. Clxt()C}a1{ q9� 3J{$3ryt-�Clttll EpL �<✓i3 aC5, raFll ? ..-..." R....a t t t i & lrC. It�,ln 2 1 s} :�C. iN, site. s 17. 1'`>'•LJ i f ax'.3) 3,_ �t �Sx° . fin f.? }lez AMENDMENT r3" t? L"r1<t` t , 7 d�tt, 11 e: 5t.ilSt t� 3't' C1C t� n YIiL" ??�i Si PC.t ?{ y v�.ECIC]:. ai�t� �t.ci3 hr LCei wll7 FiF.aJ V''1(._"4..t2 i.f {t.s.t31 C �h'� a"i7ft[,L{aS s3{ts,d t.{'lt :'„,tik: C3Cr. 0� 5{tat 7v..r•47 t2[, ifi4 4,.tY'Yts .>{a; [; 'tSL a L';iteti l]i illUlillk'ii EP7Cd tt4 F EX. SCHOOL t o k!${!P v ui 1tU"1 t_l fr tlPdj F"f j iid $}lL eUj1011 fmni Y i For `)irpoz,T �, 9 a' kj6 f�tt�u' ,'3k�e{tit z':5.. [, "I71 'i.{,S j'1'Gl:ik.f� 4. - �� be �.onstrtP44A to Ii3C.F i ii 1''7: ..91P�'i Cl 4 ` Yit..11k 'r7_ J 33 � i€lli?eliAi{rtlt)73 EXHIBIT g {j?' 4 ti4C 41t t[#''L #qf GC, sS:•4C `(A I' I#ls-. k! )"Ic I {t Fmic Nit Y nvo ( 21 year, iY'iilt �`iti. :7 P7} 4. t x a s 5 1 S '� +."�{ {1 tF,� IR- .r.,a..••' , ,1�: ..<AgATia s 1 ,., ;�, C....°..;tt;; .,c a`T; 7ic U�. ti;,l a:Ai7 2t'}1a,trii -fist I � k,7,F,c.3r. Lt' i >,-tz)2J �'w,w..��.....,- �. �� '✓1 � � ,..,.�.,....� � ,r� ��" , r� rc>t .1:Ukatlrt#lid? tR#t� , ;'sa ra usi �tt s 1 i ,rafl4n� tla�t�;rc *cr;s�t Like l�tlin� ��1�Pnrt.°Ystt. �.. i � r a,f4y f <.....,-• .._...,,,yqM .� .rrr;P'a t �i ,a j .. " t : .. �._ .�i7\+4.ltidlit: �'a(!t^.1' �'i C}&¢',U{, 1° 'ti .i' :.e tl ��#::�.c g i[a'.t"1 += 3:id< t.U32xll C:{;:ti li3d ii( .91; ➢.`i5 E4 t;i'a Xkdt; `i ou g.w,,l t Ci imply".4 ith the, CC�nditiond ir, <.,, d'_€ ®° ' �,,,, ...-- ^' i ..,.... ^""`"`. •-..a....�- -""' ✓ this !".(ter, For id.AAl15Qr 1t1 rC9C€;jai9t)i1; pl`'`t,4 Cm i7Si +c$F' �j;J#.lti{G ,.tt 296_�i+.';', '"�.,,w °"'' �°F iA'� �t �+v -"--" faC:.,.!• Al �. -✓?:; Job Number: 1 850 �,,,,. «m..-.. ��,,`'. a.i.a—•-~' It ��YS I'Fk.a F?C'i { ki'l. t I.P,�tl (J,t'y' i.. �„'; a l..• �.. f'ir41 t1tY P'N' Lt .i C: '.7 € .. .. .v,.0 �l;es .}SI3„1t4.).${4 Sv Stl €sk' 1:� 4 SI •: i7t 1'h rk-6+j P':i It .t :- iCr ij F3 't1@t `:.t i.P 1,7'T 1ta ,ll(), °IP 1711 [, 3.�1>r' 1]„a3.[r.;Y.ti ,Fh _LC7€�t{:i �Pr,s.i'.faW�,a.�...�..._. ..�-t� %` d'a' a' ��' fl t?Ia1 t i thu 317.74 C .1tikC:., Cc. 1 PGSF i4 4{low r t Yt iu { hi figs dla t'. v,kh '"1 t.Sin 14 - i_ .3:f �,- d i Proposed (Major Sifie Plan Amendment: }' ` ✓ 4> a t tti4 J`C3119Y7� i.IL:tll 311.4 t'�Cs1y ikt #.` rkl 1{_I iLS]}Yf f1{ t5 F{�''ivc:J tll tL-iltS',i'ttix Di UI.I tYi.,., `33t 't,. t;?,�, m,�,,,..v.,aww.�^-'-^ ,�a Proposed recreation area & amenities. d �,+ ✓' {. 1 c t.;u a 1Pa F t is 11 o1 ,Llstl be a 7] tt .i € a e t4iflt tIt t 3a OP 1, ... t , r iml al,}.lt ;t., n .1.. is 4> wd lA 'Z. 19,90 't-t�ex ft nl kumk D- ,\, jr-PE j 1 � �,,,^ i',✓ 4;!r,[4";Stto. �.•• trr'� ,✓' Vp i� +';,� L, 'F A a .'. � � �'"✓P, r'i' O' Y lc ci l'k t., IC9 '':yti 3•>i$l y{tk i-$i8 S) SS .?,.4J S''�V E?1, 71f?1-.e[°tI1 tiLlllti,l�. �7'l UFlCi ti 'i�t'"stc4(.efj1'C.i`)"1t.L�'i.lv'+1,(liAk.CY?i7117?I$li e.*`a�... ter`- �-" y�jy/ry g •� ry 7P t7ki� d iaSL iT aJI6{[l'"" �`i k}'?Pid; i'S} TMl903.-4 .d t� �t 1 ,l4 ,4-29-2019 Na'4 ,M S . t r C' �.P f✓ J� d r ✓ fpr' I4j`i� .3�.�ei�i'�a'a#a�l� s�..P1�=J�Lt36i�E:�''�1LI.�', L...e �,, ,""'x•;°u •*,,,,"2 �,,.., g' q� � MO ,3375, P9 63 a.wara � 1✓ a�a .��� f-•� 1Bt' ;t Cti iellzR: a#iC° iiJt €1 P7; 4} : Pi i!14 a1.,.0. kt i ':, 'tl � , P..:; Clil. t'[Jly titC 5 € F�.,i }7;1 _' -i{I �'e; r`�Ctly l;Ci rY �i,{'. Ltliti`C: �.ss �+ f #, t 1 i' 1 C a' .P4 a PLAT T 1avk. LCc lei y S Ax' ��'�+��la 3+1 icy � `SS,A Coach L�. Tex �� t ".'•N" �a�r• ''.�'w° 1 iit .. ;,£kC al tETY})Cfa4 M.S 1%'s anda41.. .1✓ tl]`_.F'U "1Y Yi rC), -. 7C.1 :?tkil i.� ba.T Oak a h1H Drive. sR 1d jt;- tkrt k i114 i Tc 1t 1'ttglV t i,lr f 8'€ cedldL, aldtt -'illslta uk e i�a •`-w• !' Public X t €ks firth d 1ra tic Pll. ;il't:l [a. I,il}3t1, y,€'st_i,t., oil Y ,...:.u:l<agelll .kxl..��,p' pry �,g ®ate. • �� . January 31, 2019 All t-.CS -,,oci tee t{,l. t. i3 3}�Ji"� tlli r�P: +. fil ],iil i."€S 11t.31...1iSscittL)Lt.li 1'4 iLcw iY t tel7: ,.lY@�;J ll �' tl l,al('5.�.` F roqu,rc Y].,. % ,)I' ;:t`iL�.:.^. 4.1 t.2(a) v*, Il 4 Z ? iio <9C� ,7.•Ct_`x:. Revision: I3I1J1 1, April 29, 2019 f IRF SPECIAL USE PERMIT SP1 -54) " SDP200200029 Minor Site Plan Amendment): N.T.S. ' hI,�E FOREST LODGE, LL Reorient facilities stormwater management 1B. 3092, Pq 310 D3. 30 P9 � 1 Puu to allow for expansion of driveway, d Scale: " 1 = 80' SDP201100003 (Minor Site Plan Amendment) : Covered storage area for the school's maintanance equipment Sheet No.: with grading to allow for a level pad to serve the structure. 80, 0 W. 160' 240 FEET SCALE: 1 " = 80' Vy copyright 0 2019 by Woolley Engineering THE COVENANT SCHOOL EXISTING 2-STORY SCHOOL BUILDING WITH BASEMENT 175 HICKORY STREET E DI=DROP INLET E=UNDERGROUND ELECTRIC EJB=ELEC. JUNCTION ELEV.=ELEVATION ES=END SECTION FY=FY1 qT1 N (', HAZIMM p M CS* VEPCO U-NDERGROUND CABIE EASEMENT D.B. 1986, Pg 24- Ln LO < Jim, DESIGN, L�NT'6CAPEARCIRDIC'M V,Q.Uw� 2137 ChmvlieMfle, VA 22902 Owner: The Covenant School 175 FRckory Street Charlottesville, Virginia 22902 P: (434) 990-7329 Job I'lumber: 1851 Data: January 31, 2019 3 of 16 Vx d-1101,1 copyright @ 2019 by Woolley Engineering copyright 0 2019 by Woolley Engineering THE COVENANT SCHOOL EXISTING 2—STORY SCHOOL BUILDING WITH BASEMENT 175 HICKORY STREET Notes: 1. See SUnlementol Landscooe Architectural Plan for concrete scaring PROPOSED NEW FENCE RELOCATE EXISTING SHED OVER SYNTHETIC TURF Ile flnklf- 0.Tx,11K1t_ 1A/ A I I %AIITU DA111KI(2 M IN 121 m PYR FLUSH CURB M BLACK CHAIN -LINK FENCING MINIMUM HEIGHT: 6' (SEE DETAIL S2.0) 10' 0 10' 20' 30 FEET BUILDING PERMIT REQUIRED vz� i\u SCALE: 1 10' w 11.2' NEW STEPS AID WALL TO MIRROR EXISTING STAIR GAGA BALL PIT WITH RAILING CONCRETE SICEWALK (TYP) 32.2' PLANTING BED Typ) — SYNTHETIC TURATYP) 26' CONCRETE PAVING (TYP) TAPER END CG-3 (TYP) Z z TIE INTO EXISTING FENCING TIE INTO EXISTING SEGMENTED RETAINING WALL. (SEE DETAIL SHEET S2.0) EX, ES X;11 X EX, rill WooLLEY ENGINEERING Consulting Civil Engineers 220 East High Street Charlottesville -Virginia 22902 (434)973-0045 www.Woolley-Eng.com M DESIGN LAM)SCAPE ARO III UCTUM RO'Dox "iM Charlowsylliv, VA 1-1902 Al MIN =_ The Covenant School 175 Hickory Street Charlottesville, Virginia 22902 P: (434) 220-7329 Job Number: 1850 OP mc W. w0buffy MC. NO. 3708V--� 4-29-2019 'rONA-t Vi> Date: January 31, 2019 Revision: w a0 Scale: 1" = 10' Sheet No.: 5 of 16 W(_ 0 V18111-1 copyright @ 2019 by Woolley Engineering THE COVENANT SCHOOL EXISTING 2-STORY SCHOOL BUILDING WITH BASEMENT 175 HICKORY STREET Notes: I See Suplemental Landscape Architectural Plan for concrete scoring patterns, concrete color finishes, benches, picnic tables, fencing details and recreation appurtanences. 2. Contractor shall field verify the locations and elevations of the existing condensation drains and existing communication utility crossings. Any conflicts with proposed new improvements shall be reported to the Engineer. 4. Contractor shall use extreme caution excavating near or around the existing communications conduits, cables and mechanical equipment, CONTRACTOR SHALL ALIGN EX. STORM STRUCTURES WITH NEW CONCRETE SCORE LINES OR REMOVE r U AND CONNECT TO PROPOSED NEW URATE INTOP=429A' STORM DRAINAGE SYSTEM 3' PVC D1=427 3 TO I- PVC T N=427, "'P= I f'429,59" - FFE=429.57' TO SCHEDULE Structure No. Inlet Type Top Invert In Invert Out Downstream Pipe Note I Ex. ES - - ±405 - Confirm OP 2 MH-1 429,30 425.30 ±425 Ex. 12" HDPE From #6 - 426.00 - - From #3 427.00 From #4 - 426.30 - - From #5 3 Trench Dr 428.60 428.10 427.70 77- 8" HDPE 4 Trench Dr 428.60 428.10 427.70 8'- 8" HDPE 5 Yard Drain 429.50 427.00 - 49'- 8" HDPE 6 Yard Drain 429.10 426.10 426.00 85- 12" HDPE From #7 - 426.10 - - From #12 7 Yard Drain 428.65 426.50 426.40 22'- 10" HDPE 8 Yard Drain 428.90 427.10 427.00 18'- 10" HDPE From #9 - 427.10 - - From #10 9 Yard Drain 429.27 - 427.40 23'- 8" HDPE 10 Yard Drain 429.15 427.50 427.40 18'- 8" HDPE I I Yard Drain 429.35 - 427,80 23'- 8" HDPE 12 Junc. Box 429.50 428.00 427.00 28'- 8" HDPE Underdrain - I - 427.20 - - From Ex. #] 5 13 12" ES-1 - 420.00 - OP, CIA-] L=47 14 DI-313, L=4' 426:1:3 - 421.00 20'- 12" HDPE 'Type A" Nose * Contractor shall match existing invert and report any discrepancy to the Engineer YD 7 TOP: 428.65 INV IN: 426.50 INV OUT: 426.40 BENCH MARK SET NAIL/CAP ELFV.=529.09' NAVE119ea mps) YD 6 TOP: 429.10 INV IN: 426.10 MITIr!&E INV IN: 426.10 3 PVC INV OUT: 426.00 U G-jL z 14- &Is + 429,40 ?.� (BALL COURT:� 4 42 2 �'63 Vv 11 ul" -I 0 EX. AJHLE71(per FIELD M 0 Co u. VEP09 UNDERGROUND < (_;ABLE LE-ASEMEN'T < Z: � q '24 0 r14 q?� 0 (n Ld ip 4'PERFORATkD PVC (TYP) SEE DETAIL SIET C6.0 L I Ld Zl' < C(-, � 5 cn LU ry U-1 V) LLJ 00 1 C-73 W 1 EX. Di, 4­1 P' 100 10' 20' 30 FEET X" MAX HT: 6SEE DETAIL S2.0 NG PERM Z, IT REQUIRED' SCALE: 1 10a. F'r-"E=41 6.24' M WboLLEY ENGINEERING Consulting Civil Engineers 220 East High Street Charlottesville -Virginia 29902 (434) 973.0045 w-,vw.Woolley-Eng.com "M M j J DESIGN P.0.box 2137 CharloWsAlle, VA 22W.2 Owner: The Covenant School 175 Hickory Street Charlottesville, Virginia 22902 P: (434) 220-7329 Job Number: 1850 Date: January 31,2019 Revision: Scale: I"= 10' Sheet No.: 6 of 16 copyright @ 2019 by Woolley Engineering 15" HDPE STORM PIPE (SEE PLAN) General Stormwater Management Construction Notes: 1. All dams and constructed fill to be within 957o of maximum dry density and 2% of optimum moisture content. All fill material to be approved by a geotechnical engineer. A geotechnical engineeristo be present during construction of dams. 2. Pipe and riserjoints are to be watertight within stormwater management facilities. 3. For temporary sediment traps or basins which are to be converted to permanent stormwater management facilities; conversion is not to take place until the site is stabilized, and permission has been obtained from the County erosion control inspector. —3n.0RA4W, ArERFLOW ­ft . -%. . 2' \r k- N Outlet protection calculations: Pipe discharge: Q10 = 8 cfs Pipe diameter. d = 1 T Riprap size d50 = 6' Apron length La = 1 I'min. (from Figure 5-20: Minimum Tailwater Condition, Virginia Stormwater Management Handbook) Width of apron top = 3' min. (W= 3-cl) Width of riprap apron = 12'min. (W = d + La) Depth of riprop blanket = 1.13'm1n. (Depth = 2.25 x d50) SITE DRAINAGE AREA EXHIBIT Summary of BMP Removal Reaulrements Drainage ArE 1 2 3 NON -WOVEN GEOTEXTILE FABRIC WITH FLOW RATE > 110 GAL/MIN/SF (GEOTEX 351 OR EQUIVALENT) KEY IN 12'INTO SOIL #3 AGGREGATE GRAVEL DIAPHRAGM (MATCH RIPRAP COLOR) 1:1 SIDE SLOPE Bioretention Maintenance and Inspection Schedule {Spring of each year): 1. Check to see if 95% turf cover or vegetation density has been achieved in the bed and banks of the dry swale. 2. Check for sediment buildup at curb cuts, gravel diaphragms or pavement edges that prevents flow from getting into the bioretention swale, and check for other signs of bypassing. 3. Check for any winter- or salt -killed vegetation. 4. Check inflow points for clogging or accumulated sand, sediment, and trash, and remove it. 5. Inspect dry swale side slopes and gross filter strips for evidence of any Nil or gully erosion, and repair it. 6. Check the bioretention swale for evidence of excessive ponding or concentrated flows, and take appropriate remedial action. 7. When sediment accumulation is noted, look for any bare soil or sediment sources in the contributing drainage area, and stabilize them immediately. 8. Check for clogged or slow -draining soil media, a crust formed on the top layer, inappropriate soil media, or other causes of insufficient Filtering time, and restore proper filtration charocte(istics. 9. Inspect upstream and downstream of check dams for evidence of undercutting or erosion, and remove trash or blockages at weepholes. EXISTING BIOFILTER SIDESLOPE (SEE PLAN) SYNTHETIC TURF WITH BACKING SYSTEM AND FALL PAD NON -WOVEN POLYPRENE GEOTEXTILE FABRIC WITH A FLOW RATE OF > 110 GALS/MIN/SF (GEOTEX 351 OR EQUIVALENT) oil Infiltration Maintenance and Inspection Schedule (Spring of each year): 1. The drawdown rate should be measured for three days following a storm event in excess of 1/2 inch in depth. If standing water is still observed in the well after three days, this is a clear sign that clogging is a problem. 2. Check inlets for sediment buildup and structural damage. Note if any sediment needs to be removed, 3. Check that no vegetation forms an overhead canopy that may drop leaf litter, fruits, and other vegetative materials that could clog the infiltration device. 4. Generally inspect the upland contributing drainage area for any controllable sources of sediment or erosion 5. Inspect and replace any damaged synthetic turf. 3" - #8 WASHED GRAVEL CHOKER LAYER ABOVE UNDERDRAIR ­` 4" SCH 40 PVC UNDERDRAIN WITH 3/8" PREFORATIONS AT 6" O.C. LOJ "Im 15AGGREGATE (SIZE BASED ON TURF MANUFACTURER RECOMMENDATIONS) Infiltration underaround reservoir calculations: Max. depth of storage= (1 /2f x td)/(nxl2) f = 0.30 in/hr tcl = 48 hrs n = 0.40 dmax = IS SA = Ty in x dmax) + [(1 /2f x ff)/] 2] Ty BMP =172 cf n = 0.40 dmax = IS f = 0.30 in/hr ff = 2 hr SA = 276 sif min. SA provided = 1,970 sf WOOLLEY ]ENGINEERING Consulting Civil Engineers 220 East High Street Charlottesville - Virginia 22902 (434)973-0045 www. W oolley-Eng. corn. L) E S I G N i V,Q.Uvx. 2137 chadutlesvill-_ VA 22902 The Covenant School 175 Hickory Street Charlottesville, Virginia 79902 P: (434) 220-7329 W AM _ M IL Job Number: 181 5 OP r, W. 70011" LIC. No. k4-29-2019 Dafe: January 31, 2019 copyright 0 2019 by Woolley Engineering I MINIMUM PIPE SUR14L DEPTH PER PIPE MWFACTURER RECO IMENDATION THE BACKFILL MATERIAL SRALL BE CRUSHW STONE OR 01HER GRANULAR MATERIAL MEETING'THE REQUIREMENTS OF CIAS S II HATER AL tom" DEFINED IN ASTM C123Mt, BEDDING & BACKFILL FOR SV FACE DRAINAGE INLETS SI4ALL BE PLACMA COWACTED LINIFOW&YINACC(IRDANCi YWFFHASTkID232f. t rMIN WIDTH GUIDEUNE eMIN THIGmESsGUIDEUNE �. ) °::• M#.. A ': ! -. h,e-'-. 1. t. � ..,.� 1. .., .. tib !: i'n t�i �.,�. � 1 �♦-+.. :.inow, 6 " - CLASS A3 CONCRETE 6"x6"-W2.1 xW2.1 WWF 4" - #21A OR #57 AGGREGATE BEDDING MATERIAL WIDTH VARIES, SEE PLAN Yd':1' SLOPE ■ —" 511 ifi... 6" COMPACTED AGGREGATE 1. 3/9" EXPANSION JOINT BASE - VDOT #21-A 2• SAW CUT CONTROL JOINTS, MAX 6' O.C. EXPANSION JOINTS, MAX 30' O.C. COMPACTED SUBGRADE 3. WHERE SIDEWALK MEETS CURB WIDTH SHALL BE 6' CBR = 10 UNLESS OTHERWISE NOTED. 4. SCORING PATTERN SHALL MATCH EXISTING, 5. CONTRACTOR SHALL MATCH THE COLOR OF THE EXISTING SIDEWALK. THREADED PLUG ADJUSTAI RIiIi WYE ' LANDSCAPED UNDER AREAS HARDSCAPE BACKFILL SHALL COMPLY WITH LANDSCAPE PLAN & SPECIFICATIONS l; CLASS I BACKFILL IN ACCORDANCE WITH SECTION 302 OF THE VDOT ROAD & BRIDGE D +12" SPECIFICATIONS NOTES: I, WHERE ROCK. IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6" BEDDING OF CRUSHED STONE. 2. FOR COMPACTION OVER PIPE TRENCH USE APPROVED HAND OPERATED MECHANICAL TAMPER, GENERAL NOTES - PERIMETER FENCE: * THOUROUGLY COMPACTED BY HAND OR APPROVED MECHANICAL TAMPER VDOT 21 A CRUSHED GRAVEL, COMPACTED TO 95 0 MAXIMUM DENSITY INITIAL BACKFILL (6" LIFTS) SPRING LINE OF PIPE HAUNCHING BEDDING STONE (4" MIN.- 6" MAX.)]— AX.) DUST FOUNDATION (SHALL BE REQUIRED WHEN SOIL CONDITIONS ARE UNSTABLE.) (JAMMAarl rr:-1 CONCRETE STEPS 5„ y. r-7 TIE-IN GRADE ° 4 21 5,1 _ 311 411 3, it 1 e 1 / ASPHALT PAVEMENT CONCRETE CURBING C - (T'YP.)- N.T.S. 1.) POSTS AND BRACES: POSTS AND BRACES ARE TO CONFORM TO ONE OF THE TYPES ALLOWED BY THE SPECIFICATIONS- ONLY ONE TYPE TO BE USED PER INSTALLATION. POSTS AND BRACES WILL BE TO THE SIZE SHOWN ON THE DRAWINGS. 2.) WIRE FABRIC: WIRE FABRIC SHALL BE NO. 9 GAUGE WITH A 2" MESH, WIRE FABRIC IS TO CONFORM TO ONE OF THE TYPES ALLOWED BY THE SPECIFICATIONS, AND IS TO BE COMPATIBLE TO THE TYPE OF POST USED. 3.) MISCELLANEOUS: STEEL RODS AND FITTINGS ARE TO BE HOT -DIPPED GALVANIZED IN ACCORDANCE WITH ASTM AI53- FOR GATES EXCEEDING 9'-0" IN WIDTH, ROLLED FORMED STEEL POST WILL NOT BE ALLOWED. 4.) UTILITY NOTE: CONTRACTOR TO COORDINATE LOCATION OF FENCE POSTS & FOUNDATIONS WITH UTILITY LINES SO AS NOT TO INTERFERE WITH THESE FACILITIES. TYPICAL 8' PERIMETER FENCE DETAIL �4J`�RE.9EaTc��h►7l►�.hr 2" SM-9.5A B" COMPACTED AGGREGATE BASE - VDOT #21-A COMPACTED SUBGRADE CBR=10 ASPHALT PAVEMENT SECTION 1 1 - 12" AT END POST 10" AT INTERMEDIATES A EXPANSION JOINT (WHERE APPLICABLE) A u STRETCHER BAR B, TO BE 4" MAX. FROI TOP AND BOTTOM l fiYU SPACED 1-2" OC MAX. END POST DETAIL NOT TO SCALE kBRIC STRETCHER BAR TO ENGAGE EACH FABRIC LINK CARRIAGE BOLT #6 WIRE CLIP HOG RINGS SPACED I SPACE 10" MAX. 24" MAX. LINE POST CONNECTION TOP RAIL CONNECTION FENCING FABRIC CONNECTION DETAILS NOT TO SCALE -or m I{ DESIGN P,O.Lzt,x Zia: I C[u12Iottc v 111 , V 1 e 02 I AA..' 114 The Covenant School 175 Hickory Street Charlottesville, Virg Wa 22902 P: (434) 220-7329 copyright 0 2019 by Woolley Engineering N.T.S. of 1 V� be chel ALL DIMENSIONS ARE SHOWN IN INCHES f 10.001. , I L 29-92 ................. ..... . ...... . ..... PIC"IC TABL D N.T.S. LS-200 I LS-200rm*S 42" x 72" ACRYLIC RACKBOARD WITH EDGE PADDING 5" SQUARE STEEL EXTENSION ARM S'SQUARE STEEL UPRIGHT Niff4flumme, 42'x 7Z'STEEL BACKBOARD LS-ZOORS FEATURES: • E36" PLAY SAFE AREA • UPRIGHT & E-XTENSION AF M ARE CONSTRUCTED OUT OF HEAVY` GAUGE STEEL., • FIXED HEIGHT OF 10'HIGH RIM, HEIGHT CANS ADJUSTED AFTER COURT RESURFACING, *OFFICIAL SIZE BACKBOARD 42" x 7Z'ACRYLIC OR STEEL BOARD. * LS-200 COMES WITH ACRYLIC BACKBOARD WITH EDGE FADDING. " LS-20URS COMES WITH STEEL BACKBOARD. PLAYING SURFACE T' P), 48" RECOMMENDED 314" X 42" (4 PLACES) 54" REFIAR TO BE TIE TOGETHER (TO BE SUPPLIED 13Y INSTALLER) 6'CCNCRETE PAD OR DOUBLE 6" CONCRETE BLOCKS RM Mlrmllnpi CATE ay LS-2001 - LS-20ORS INI NAL. W2 4WO EOATC: x DRAW Bv� L � Moune T. 106r2012 S-2001 LS-20ORS 111 Z M �HK CHK DATE FAX; X : VFEl &2012 :: UOLL FREE) W.0 444,1779 (SAL&a�! M0,4440628 (rN0) e,60.447,3001 (LQQAL) OAPOR 'MLc' i RQ SPORT$, LLe,$7fi HARTFORD TURNSKIE, WATERFORV, CT OD305 USA I I OFF AND JJAYF I —BASKETBALL HOOP DETAIL N.T.S. a I A United Volleyball Supply, LLC. Company - 14615 NE 91stSTBld,98, REDMOND, WA98052-1996-r2CG7OVOLLEYBALLUSA.COM ta—m-095k i-Al. net to fit perfectly between the poles. Oty. 2 - Bazooka Net Adjustment Collars (A) 61 You may need to create a loop on the 5teei cable on one end of Clty. 6 - Nettormection Botts and Nuts (8) your net using (2) provided CABLE CLAMPS (K) (large), If you have a + Qty-2 - 3' Bolts for winch assembly (DI) net with rope cable you will need to tie a loop knot In both sides of the -Qty, 4.2 V Dolts for upper and lower net connections (82) rope in your Volleyball net. Make loops In both the top and bottom Qty. 2 - Palm Bolts (C) (Pre -installed) rope of the net. Refer to diagram to( instructions on HOW To TIE A Oty: 2 -Hex Set Bolt (D) (pre -installed) LOOP KNOT, Oty. 1 - Tension Strap with Cam -Buckle (E) 71 Connect the loop on the top cable of your net to the top of the -Clty.3-Regula C4mbfneer Clips (F) COLLAR 2 (A) using a CARIBINER CLIP (F) and 3' BOLT (82l. Oty. I - Net Tension Winch (6) 8) On the other end of your net, feed the sarne cable through the Qty. I - Net Adjustment Pulley (H) PU LLEY on COLLAR 1„ Qty. I -Allen Wrench W 9) Place the loop of this cable over the stern found on your WINCH Qty, 4 - Cable Clamps (K) (2) large clamps for top cable, (2) small (0 on COLLAR 1 (A), clamps for lower cable. 10) Turn WINCH IGJ to tighten the top of your volleyball net, 11) If the top of the net does riot reach desired tension you may P01"ALImmasn"ME need to shorten the cable by adjusting your loop made with CABLE Ground Sleeves for new installation CLAMPS W ilarge size). - Vekra Side Straps for serrcomp net available at additional cost. 12) To tighten the bottom of your volteyball net, you may need to 4olePadding. create a loop in the bottom cable ofyour net using (2) provided CABLE - Stainless Folding Gear Winch, CLAMPS (K) (small size) 131 Connect one end of your bottom cable to the 31 BOLT (82) orl the COLLAR 1 (A) using CAMBINER CLIP (F). Setting Up your Bazooka Hardware Volleyball System, borate all 14) On the other end, connect the same cable to the end of the parts listed on Bazooka Hardware checklist (Above): provided TENSION STRAP (E). (Typkaflywe snake the loop ourselves about 3-6 Inches from where the cable leaves the bottom of the act. 1) Comiea WINCH (G) to collar using two provided 2 'A'BOITS, (61) You nerd some space between the cable loop and the COLLAR ' fA) to with. nuts. (Make sure to have the WINCH, (G) ottenAcd so the (ockfaq install the CAMBUCKLE STRAP (E) to tighten the bcatomofyour nett gear tooth is on the bottom Side of WINCH (0). 15) Connect the other end of the TENSION STRAP(P* tothey BOLT 2) Place 2 %'BOLT5 (81) through holes and lighten nuts, (52) on COLLAR 2 (A). Using your hand, pull the loop strap to tighten 3) Loosen all 4HEX SET BOLTS (D)ancl slide both COLLAR I (A) over the bottom ofyour [let, pole and COLLAR2 (A) over other pole, . lithe bottom ofthe net does not reach desired tension you may 4), Using a tape measure, adjustcollar to desired height,use PuLtEY need to shorten the cable by adjusting your loop made with cable (G) and HEX SET DOLTS (D)as measuring points cif reference as these clamps. partswill determl Q. the actual height ofyour volleyball net, Men's Volleyball net height: 8 feet from ground, 5) Turn HEX SET BOLTS (D) to fasten collar to pole, Do this with both Womensvolfeyball net height: 7 feet 4 inches from ground. poles. Suggested Co -Ed volleyball net height: 7 feet a inches from ground. Preferred distance between poles is 36, 361 allows Y()U(r standard HOW TO TIE A LOOP KNOT FOR KEVLAR ROPADE CUT UNDESIRED LENGTHS (OPTIONAL), FLAME TREAT ENDS OR CUTTINGS AREA WITH MATCH OR LIGHTER TO KEEP CORD FROM FRAYING. USE CAUTION WHEN WORKING WITH FIRE. VOLLEYBALL NET FOUNDATION DETAIL N.T.S. A United Volleyball Supply, LLC. Company - 146,15 NE 91 st ST, Bldg 8, REDMOND, WA 98052 - 1996-20070 VOLLEYBALLUSA.COM PH: 1-800-494-3933 - FAX: 425-827-2230 FLOOR SLEEVE CAP (3 INCH DIAJ FLOOR SLEEVE FLOOR COVERING (SOCKET), FLUSH WITH CONCRETE FLOOR. REBAK 4 PLACES. DRIVEN 18" INTOTHE BOTTOM OF T,V—r- W7111-W01 IMPROVE STABILITY. (OPTIONAL - L I 18INCHES MIN[MUM 24 INCHES RECOMMENDED FLOOR SLEEVE (SOCKET). FLUSH WITH CONCRETE FLOOR. --I amm FOR EXISTING ASSEMBLY WV1.#TVPT'W*1P "t FORTIGHTENING REBAR (OPTIONAL - NOT INCLUDED) REBAR, 4 PLACES. DRIVEN 18" INTOTHE 60TTOM OF THE HOLE WILL Ilvirnuvr_ a 1MDI1L_J I T. (OPTIONAL - NOT INCLUDED) VOLLEYBALL NET FOUNDATION DETAIL CEMENT SUB -FLOOR SHOWING FINAL ASSEMBLY BINDING WIRE COIL FORTIGHTENING REBAR --------- � (OPTIONAL. - 241NCHES NOT INCLUDED) MINIMUM N.T.S. EM SLEEVE CAP APPROXIMATELY FLOOR SLEEVE CAP (6 INCH DIA. COVER,) CEMENT SUB-FLOaR 30 INCHESAPPROXIMATE I CONCRETE STEPS 41 I 1 :. : 22' 36' (4) - #4 REBAR f� 3.5" 12' Note: Before cutting sleeve verify that bottom elevations of sleeves are equal Wbou.EYENGiNEERiNG Consulting Civil Engineers 220 East High Street Charlottesville .'Virginia 22902 (434)973-0045 www.WooRey-Eng.com Charlottesville,, VA =—NU2 707."A I =_ The Covenant School 175 hickory Street Charlottesville, Virginia 22902 P: (434) 220-7329 RECRLEA-00"ON 1, Ew"WIPMENT DETA LS Job Number: 1850 3 Eke WOOLLEY 3708C_-'e, 4-29-2019 Date: Ap(il 29,2019 copyright a 2019 by Woolley Engineering 9 of 16 1//, 061 ---W� /�Vlc V� � THIEC VENANT�StkddL - MIDDLE SCHOOL L: AECREATION:AREA� p Oncing tan S,ubmi A: rd 22, 2019 . ...... . . . .... QTY SYMBOL BOTANICAL NAME COMMON NAME SIZE INSTALLED ROOT AMELANCHIER X GRANDIFLORA "AUTUMN 3 AG BRILLIANCE" AUTUMN BRILLIANCE SERVICEBERRY 8'HT. B&B 3 ARA ACER RUBRUM "ARMSTRONG" JARMSTRONG RED MAPLE (COLUMNAR) 2.5" CAL B&B 4 MV MAGNOLIA VIRGINIANA "HENRY HICKS" HENRY HICKS' IRGINIA MAGNOLIA (COLUMNAR) 8'HT. B&B REEN TREES:, j B&B 7 -ro THUJA OCCIDENTALIS "EMERALD GREEN EMER L GREEN ARBQViTAE A S'HTe B&B :SHRUBS B&B 10 FG FOTHERGILLA GARDENII DWARF FOTHERGILLA 30" HT. CONT. 1 MV I MV 10 IC ILEX GLABRA "SHAMROCK" DWARF INKBERRY 30" HT. CONT. 23 IV ITEA VIRGINICA "LITTLE HENRY" LITTLE HENRY VIRGINIA SA EETSPIRE 18" HT. CONT. K" S, ORNAMENTAL GRASSES, p. A GR PUNDCOVER 538 LIRIOPE SPICATA CREEPING LIRIOPE I QT CONT 59 LS 75 LS MULCH MULCH 24 PV PANICUM ViRGATUM "SHENANDOAH RED" DWARF SWITCH GRASS 3 GAL. CLONT 59 LS LAWN - SOODIED. 1,740$F:�� 777F 75 LS j, 1 MY I MV —13 LS 22 LS 50 LS 90 LS = I MW nw-wMIRAURUT M, Notes: 1. This sheet is for landscape only. 10' 0 10, 20' 30 FM 2. All plantings illustrated on this plan, other than sod and mulch, are optional. SCALE: 1 10' 3. Contractor shall refer to Suplemental Landscape Architectural Plan for concrete scoring patterns, concrete color finishes, benches, picnic tables and recreation appurtanences. 4. Contractor shall use extreme caution excavating near or around the existing communications conduits, cables and mechanical equipment. JJMDES IGNtt P.O.Bak ,13,7 CharfoLtesville, 6A12902 The Covenant School 175 Hickory Street Charlottesville, Virginia 22902 P- (434) 220-7329 ..j ;,u E < z (D de > w w < 4e-1 w U-j LL > z :D U Job Number: 1850 OP C W. WOOS MC. NO. 37011e,-' AV 0 4-29-2019 Date: April 29,2019 Revision: Scale: r ® 10, Sheet No.: L 1 90 copyright C) 2019 by Woolley Engineering 10 of 161 Vic Vj -/w/ 7 1 1 : -Iff, gzpw &11 WXjfMN kFITWIl 191FAI RIEVIN WANWINUMAMNIft SLOPE PLANTING BED FOR POSITIVE DRAINAGE io 0 .0 0 o/ F 12" MIN. PLATING SOIL. USE STORED EXISTING TOPOSOIL AND/OR % IMPORTED TOPSOIL. I�I I I I I I -I !� I I I !mil I I-1 I I III III III=III III=III III III III III=III III III rn f­7 C', C SET TOP OF ROOTBALL 1 MIN. cl� CID ABOVE FINISHED GRADE ct, C.-i U C­(, , , . � A L M 9,CALE: NOT TO SCALE 2" X 2" HARDWOOD STAKES DRIVEN FIRMLY A MINIMUM OF 18" INTO THE SUBGRADE PRIOR TO BACKFILLING FLEXIBLE PLASTIC CHAIN -LINK ARBOR TIES SHALL BE USED MULCH 3" DEEP IMMEDIATELY AFTER ON MAIN STRUCTURAL BRANCHES PLANTING AND WATER THOROUGHLY. FORM SAUCER WITH 3" HT WATERING BERM .... ...... 1 77 -I MI I I_.____ =1 I ! I_ I I; BACKFILL PIT WITH STORED —IIE EXISTING OR IMPORTED TOPSOIL TOY3 FULL. WATER TO SETTLE SOIL, THEN BACKFILL TO FINISHED GRADE. 3 X BALL DIA. SCALE: NOTTOS AI-E copydght 0 2019 by Woolley Engineering MULCH 3" DEEP IMMEDIATELY AFTER PLANTING AND WATER THOROUGHLY. MAINTAIN SAUCER ON LOWER SIDES OF PLANT TO RETAIN WATER II t BACKFILL PIT WITH STORED EXISTING OR IMPORTED TOPSOIL TO Y3 FULL. WATER TO SETTLE SOIL, THEN BACKFILL TO FINISHED GRADE. I I , , III—) * PLANT SO THAT TOP OF ROOT BALL IS EVEN WITH THE FINISHED GRADE * PAINT ALL CUTS OVER I" DIA. * FLAG ARBOR TIES WITH SUWVEYOQ, TAPE I■ III iii ARBOR TIES 3 2"X4"X24" PRESS TREATED STAKES •- TOP OF STAKE R" ABOVE GROUND - 20" + BALL D IA. W.411 CUT AND REMOVE BURLAP FROM TOP 2/3 OF ROOTBALL WAAMI 0 1110 14 1 00 01 M- 1 X, e% r% r-% r' A r,% MEN SCALE: NOT TO SCALE �m SCALE: NOT TO SCALE SET TOP OF ROOTBALL ABOVE FINISHED GRADE FORM SAUCER WITH WATERING BERM ,'w"ACKFILL PIT WITH STORED I =XISTING OR IMPORTED TOPSOIL TO Y3 FULL. WATER TO SETTLE SOIL, THEN ------------ PLANT SO THAT TOP OF ROOT BALL IS EVEN WITH THE FINISHED GRADE PAINT ALL CUTS OVER 11" DIA. FLEXIBLE PLASTIC CHAIN -LINK .49BOR TIE 101 *0 r"I 0 A. 0 rr �7,A HARDWOOD STA&ES 3 STAKES 2" X 2" DRIVEN (MIN. 18") FIRMLY INTO SUBGRADE PRIOR rO BACKFILLING STAKE -4" ABOVE FIRST BRANCHES �`LANTING PIT DEPTH IS AVERAGE DISTANCE BETWEEN TRUNK FLARE AND BOTTOM OF ROOT BALL, EFULLY EXPOSE TRUNK FLARE IF REL'ESSA, SPECIFIED PLANTING MIX WATER & TAMP TO REMOVE AIR POCKETS NOTE: STAKING AS REQUIRED M� 999M MULCH 3" DEEP IMMEDIATELY AFTER PLANTING AND WATER THOROUGHLY. SHRUB PLANTING_ SCALE: NOT TO SCALE (MULCH 2" DEPTH IMMEDIATELY AFTER I.-: PLANTING AND WATER :Z THOROUGHLY.) y z MULCH rr TREE PLANTING - VERTICAL STAKES SCALE: NOT TO SCALE s 9 WOOLLEY ]ENGINEERING Consulting Civil Engineers 220 East High Street Charlottesville - Virginia 22902 (434) 973.0045 www.Woolley-Eng.com jjm� I DESIGN' ROXVN2137 Chid ilesvillcVA22902 Owner: The Covenant School 175 Hickory Street Charlottesville, Virginia 22902 P: (434) 2220-7329 I LANDSCAPE, DETAILS Job Number: 1850 OP r. V. TOORRY LTC. NO. 3708e�-"' A; k Vd 4-2N1101 -29 14� At Sv Date: April 29,2019 Revision: WIN jj LD 2 NEW GAURD RAIL TO MATCH EXISTING zA r' 211 CLR #4 AT 12" (HORIZ) #57 STONE BACKFILL (FULL HEIGHT) "P" BARS "L" BARS CONT RETAINING WALL SCHEDULE DIMENSIONS REINFORCING Ortf �1 VV" "D" BARS 111 BARS "M" BARS 11011 BARS "Pl* BARS _ V-0" - 4t-On --- -- -_ - 01 _80# 0'-8" 2'-4" 9" #4 1 @ L__ I (3) - #5 _ i - -------- #4 , 9" #_4 @ 18" 41-0"- 6-0" O'- 10" 1 �4' T-2` #5 @ 12" (4) - #5 #5@ 12' #4 @ 12" 61-01' - V-0" 11-01f 2141 40-4" #5 @ 12H (4) - #5 #5 12" #4@ 12" 8'-0" - 10'-0" 1-2' 3'-10" 1 605 @ 1 --- %" 42" 5 () - #5 #5 12" _ @ 95 12" @ 12' NOTES: 2" 1. DESIGN CONCRETE STRENGTH.- 3000 PSI AT28 DAYS. 1R 2, REINFORCING STEEL: GRADE60, 3, MAX SOIL BEARING PRESSURE = 2000 PSF (ASSUMED). 4, PROVIDE WALL CONTROL JOINTS AT 201-01' MAX. scr 4 L I ._01 "B" 3/4" = V-0" NEW 24" RAILING NEW 42" RAILING NEW WALL - MIRROR DIMENSIONS OF ATTACHED EXISTING STAIR EX. 42" RAILING,. EX. WALL NOTE: RAILING LAYOUT 15 FOR GRAPHIC REPRESENTATION ONLY. CONTRACTOR SHALL MATCH EXISTING RAILING. EX. 42" RAILING #4 AT 12" EA WAY ZY, cz 0 C U) GRU6HEU6lUNL WRAPPED IN FILTER FABRIC, DRAIN TO ru"NETAIL A E SUITABLE OUTLET Q EQ (3) 3/4" X 3/4" VEE 0 GROOVE JOINT -CUT ALTERNATE NEW WALL TO EXISTING ul EACH FACE 0 #4 X 2'-0" ADHESIVE SET DOWELS AT 24' OC (HILTI HY-70 ADHESIVE SYSTEM, OR EQUIV) HORIZ BARS A JOINT WALL CONNECTION 4 A Ali PLA N CEI L DATE: 01/23/2019 DMWPV JOB NUMBER. 1901-47 SHEET NO: Stephen D. Barber EARTH FACE ----- -- LiC� No, 025731 % e%kl SK�l WALL CuimTRO"'L Ju"-**INT NO SCALE At. EX. EX. WALL WITH RAILING EX. STAIRS EX. BLEACHERS EX. WALL EX. STAIRS NEW STAIRS WITH RAILING SECTION C-C NEW 24" RAILING NEW 42" RAILING NEW WALL EX. 42" RAILING EX. WALL EX. WALL WITH RAILING EX. STAIRS EX. BLEACHERS EX. WALL DESIGN UAN r)SCAPF, 3 [,C} 11TEC-1-111ZE 1',0.Uux2137 Charlc?W�_v e, 4Fr17a902 N I �141 - The Covenant School 1-75 Hickory Street Charlottesville, Virginia 22902 P: (434) 220-7329 va OP LTC. NO. 3708C-- ks�j 4-20 NQ_201Q AL "Z A ,,,, F SV Scale: As Noted Sheet No.: U 12 of 16 copyright 2019 by Woolley Engineering Vic qr)1q'. rNERAL NOTES: LO STRIP VEGETATIVE AND ORGANIC SOIL FROM THE WALL AND &EO6kIb ALIGNMENT 2.0 BENCH CUT ALL EXCAVATED SLOPES. 3,0 DO NOT EXCAVATE BEYOND EXCAVATION LINES SHOWN ON PLAN UNLESS DIRECTED BY THE GEOTECHNICAL ENGINEER TO REMOVE UNSUITABLE SOIL. 4.0 CONTRACTOR SHALL ENSURE TEMPORARY EXCAVATIONS ARE STABLE AND PROVIDE EXCAVATION SUPPORT IF NEEDED, 5,0 GEOTECHN11CAL ENGINEER SHALL VERIFY FOUNDATION SOILS AS BEIN5 COMPETENT PER THE DESIGN PARAMETERS. 6.0 LEVELING PAD SHALL CONSIST OF COMPACTED 5AND, GRAVEL, OR COMBINATION AND SHALL BE A MINIMUM S-INCH THICK LAYER WITH A MINIMUM WIDTH OF 24 INCHES. AS AN ALTERNATIVE, A MINIMUM 3-INICH THICK LAYER OF LEAN CONCRETE (FLOWABLE FILL) WITH A 28-DAY COMPRESSIVE STRENGTH OF 200-300 PSI MAY BE USED AS A LEVELING PAD, TO A. 4-INCH-DIAMETER SLOTTED DRAINAGE PIPE SHALL BE INSTALLED BEHIND THE WALL AND CONNECT TO WEEPHOLES INSTALLED AT THE BASE OF THE WALL (20 FEET ON CENTER) AND EXTEND BEYOND THE FINAL GRADE TO DAYLIGHT (SEE DRAIN DETAIL). 8.0 DRAINAGE AGGREGATE AND UNIT (CORE) FILL SHALL CONSIST OF CLEAN ANGULAR GRAVEL (VDOT NO. 57 STONE). MEETING 'THE FOLLOWING GkADATION AS DETERMINED IN ACCORDANCE WITH ASTM D-422. SIEVE SIZE PERCENTAGE PASSING i-1/2 INCH 100 I INCH 95-100 112 INCH 2b - 60 NO, 4 0-10 NO, 200 0-5 9.0 GEOGRIDS SHALL BE LAID HORIZONTALLY ON COMPACTED BACKFILL POP THE REQUIRED 6E06RIb LENGTH (6L) IN THE TENSILE STRENGTH DIRECTION (PERPENOICULAR TO WALL FACE) NOTED ON THE WALL PROFILE. THE GEOGRIb SHALL BE PLACED WITHIN ONE INCH OF THE FRONT FACE OF THE UNIT BELOW AND EXTEND HORIZONTALLY OVER COMPACTED FILL, 10.0 ANCHOR VERTICA UNITS MOWED DIMENSIONS SHALL BE 8 INCHES HIGH BY 18 INCHES LONG BY 11 INCHES DEEP AND SHALL NOT DIFFER MORE THAN + 1/8 INCH IN ANY DIMENSION. 11,0 A 0.56-INCH SETBACK PER UNIT (LOCATOR LUG) SHALL BE MAINTAINED FOR PROPER BATTER (I.E. 4 DEGREE CANT FROM VERTICAL), 12;0 GEOGRIDS SHALL BE PLACED 'WITHIN I IWH OF THE FRONT FACE OF THE UNITS AND &E067RIDS PULLED TIGHT (AFTER PLACEMENT OFTHE NEXT COUP 5E OF BLOCK UNITS) TO REMOVE 5LACK AND TO INTEGRATE GEOGPIDS AND UNITS. 13,0 FIELD ADJUSTMENTS OF BLOCK ALIGNMENT MAY BE MADE ON NON -REINFORCEMENT LAYERS WITH THE U5E OF SHIMS OR ASPHALT SHINGLES TO RAISE ONE COURSE OF BLOCK BY A. MAXIMUM OF 1/4 INCH VERTICAL HEIGHT, DESIGN PARAMETERS: I BUILUIN& CODES 2015 VIRGIN]IA UNIFORM STATEWIDE BUILDIN9 CODE (USBC) 14,0 REINFORCED FILL SHALL CONSIST OF GRANULAR SOIL FILL AND 2015 INTERNATIONAL BUILDING CODE (IBC), WITH U5CS SOIL TYPES GP, 6W, &M, 6C, SW, SP, SM, OR SC 2 THE WALL PROFILE 15 BASED ON INTERPRETATION OF THE SITE PLAN, WITH A MINIMUM ANGLE OF INTERNAL FRICTION, +', OF 28 DEGREES SHEET NO. r-5,0, DATED JANUARY 31, 2019 (REV. 3/22/19), AS OUTLINED IN DESIGN PARAMETERS - NOTE 5- PREPARED BY WOOLLEY ENGINEERING. LOW PLASTICITY SILT OR CLAY (ML-CL) CAN BE USED SUBJECT TO 3 WALL DETAILS SHOWN ON THIS PLAN ARE FOP ANCHOR VERTICA APPROVAL BY THE GEOTECHNICAL ENGINEER, SEGMENTAL RETAINING WALL (SRW) UNITS MEETING THE NATIONAL MAXIMUM PARTICLE SHALL BE LIMITED TO 4 INCHES IN DIAMETER, CONCRETE MASONRY ASSOCIATION (111CMA) CRITERIA FOR SkW WALL SYSTEMS. THE FINE FRACTION (MINUS NO, 40 SIEVE) SHALL HAVE A MAXIMVU� 4 WALL. DETAILS SHOWN ON THIS PLAN ARE FOR ANCHOR VERTICA LIQUID LIMIT (LL) OF 45 AND AMAXIMUM PLASTICITY INDEX (PI) (8`H) :TRW UNITS USING 5TRATAORID 5&200 GEOGRIDS OF 15, THE BACKPILL SHALL BE FREE OF DEBRIS AND ORGANIC MATTER. IN THE REINFORCED FILL, HIGHLY EXPANSIVE SOILS (MH-CH) SHALL NOT BE USED IN THE 5 THE DESIGN OF THE SEGMENTAL RETAINING WAI I (`kW) REINFORCED FILL ZONE. ASSUMES THE FOLLOWING PARAMETERS: 15,0 REINFORCED FILL SHALL BE PLACED IN 8-INCH LIFTS AND 7.1 Macst FRICTION COMPACTED TO A MINIMUM OF 95V6 OF MAXIMUM STANDARD SOIL SOIL UNIT WEIGHT ANGLE COHESION PROCTOR DENSITY (ASTM D-698) AND WITHIN - 3 PERCENTA&E CONDITIONS Type (PCF) (D E&) (?5F) POINTS OF OPTIMUM MOISTURE CONTENT, COMPACTION TESTS SHALL REINFORCED FILL Sandy SILT or More &ranular 115 28 0 BE PERFORMED AS THE WALL 15 INSTALLED, COMPACTION WITHIN RETAINED SOIL 5Gndy SILT (ML) 115 28 0 3 FEET OF THE WALL SHALL BE LIMITED TO HAND -OPERATED EQUIPMENT, FOUNDATION SOIL Sandy SILT (ML) 115 28 too 16O A VIBRATORY PLATE TAMPER SHALL BE USED TO DENSIFY NO, 57 STONE, COMPACTION, TESTS CAN BE WAIVED 6 SOIL 5TREMTH PARAMETERS ARE BASED ON V5E OF SANDY SILT OR MORE WHERE NO, 57 STONE 15 USED AS REINFORCE[) FILL. GRANULAR SOIL.IN THE REINFORCED FILL ZONE, CAN -SITE LOW PLASTICITY ITT CONTRACTOR SHALL SLOPE SITE GRADES TO DIRECT SURFACE SOIL CAN BE REUSED FOR FILL PROVIDED THE SOIL IS PLACED IN H-INCH LIFTS RUNOFF AWAY FROM WALL AT END OF EACH DAY TO AVOID AND EACH LIFT 15 COMPACTED TO A MINIMUM OF 95% OF MAXIMUM WATER DAMAGIN& THE WALL WHILE UNDER CONSTRUCTION, STANDARD PROCTOR DENSITY, AND WITHIN PLUS OR MINUS 3 PERCENTAGE 18.0 ANY SURFACE DRAINAGE FEATURES, FINISH GRADING, PAVEMENT, POINTS OF OPTIMUM MOISTURE CONTENT, USING PORTABLE COMPACTION OR TURF SHALL BE INSTALLED IMMEDIATELY AFTER THE WALL IS COMPLETED, EQUIPMENT, 19,0 IF SITE AND SOIL CONDITIONS, WALL GEOMETRY, OR WALL LOADING ARE DIFFERENT THAN, THE DRAWINGS AND THE DESIGN DO NOT USE HIGH PLASTICITY CLAY (CH-M.H), ROOTS OR TOPSOIL IN REINFORCE PARAMETERS, THE CONTRACTOR MUST CON -FACT THE WALL DESIGN ZONE, ANY SOFT, SATURATED SOIL ENCOUNTERED IN SUB&RADE SHALL BE ENOINEER, PRIOR TO PPOCEELANG WITH THE CONSTRUCTION OF THE WALL. UNDERCUT AND REPLACED WITH CRUSHED STONE TO STABILIZE THE 20,0 A MTN 42" TALL HANDRAIL OR FENCE SHALL BE INSTALLED ON THE UPPER FOUNDATION 5UB6RADE OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER, SIDE OF THE WALL WHERE SPECIFIED. DETAIL FOR THE GUARD POSTS AT THE TOP OF THE WALL ARE PROVIDED FOR PLACEMENT OF POSTS. WALL A - MAX, EXPOSED WALL HEIGHT = 6 FEET FRONT SLOPE =MAX 2HIV BACK5LOPE BEHIND THE WALL = LEVEL SURCHARGE AT TOP OF WALL = 100 P SF MIN FACTOR OF SAFETY (SLIDING-7) = 1,5 MIN FACTOR OF SAFETY (OVERTURNING) 3 2,0 MIN FACTOR, OF SAFETY (BEARING CAPACITY) = 2,0 Open Cells DESIGN SOIL BEARING PRE55URE = 1,500 PSF Tilled With Stone) (SEE NOTE BELOW EACH WALL PROFILE) "I— Top Locator Lug VI CONNECTION DETAIL (Not to Soale) 1.Albemarle County, Virginia CIRCEO GEOTECH Circeo 1i956 Suckland Mill lkoad Geotechnicat 11 Engineering, P,C Roanoke, Virginia 24019 -2379 Phone. (540) 366 # m� n. 4EGEND I The CwW.—, , �t_ I Albemarle Cap Unit (4" Height) Anchor Vertica Stone Cut Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick Compacted 21 A Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cup Unit) Dow Bottom of Wall (Including Embedment) 200, — 'StrataCirld 56200 6 L 6eogrid Length (ft) 0 4" brain Pipe to Daylight RETAINING WALL A sta, 0 to sta. 115.5 Viewed From Front Face of Wall icin Soi I Bearinc) Pressure Scale; Luffloffim _10 20 9 OW 5 U 956 8 tk Iona mill'Road Roanoke, Virginia 24019 Phone- (W) 366-2379 Jiml LAND.AC! ,.A RCI flTEC! U Chadottcsvilh,,VA2229CY2 The Covenant School 175 Hickory Street Charlottesville, Virginia 22902 P: (434) 220-7329 rt h. job Number: 1850 Date: January 31, 2019 Revision: AP61 29,2019 copyright @ 2019 by Woolley Engineering 13 of 16 Ild or-11i'1111-i �* 1111112,0211:11011, ,-ft Covenant Upper School rosion and Sediment Control: Minor Site Plan Amendmerd The County of Albemarle, Virginia PROJECT DESCRIPTION The scope of this E&S narrative and plan is for the purpose of adding a recreation area and other amenities to the Covenant School property. A total of approximately 0.5 acres will be disturbed during construction. EXISTING SITE CONDITIONS The topographic and built improvements existing on the subject property are depicted on the accompanying E&S plan. The area of disturbance is entirely comprised of an existing courtyard. The existing courtyard was in general accord with the original approved site plan (SDP 00-96.) ADJACENT AREAS Hickory Street forms the southern border to the site. Residential lots border the site to the north, south, east and west. The west border of the site is adjacent to Southwood Mobile Home Estates. The stream running through the site is a tributary to Biscuit Run. OFF -SITE AREAS All land disturbing activities shall occur on -site and within the limits of project shown on the plans. At this point, no off -site borrow, waste or grading activity will occur. SOILS This site is located in a geologic area referred to as the Piedmont Physiographic Province. The soils in this geologic area are weathered from the underlying metamorphic bedrock. The map units on the detailed soil map depicted on the Erosion and Sediment Control Plan represent the soils in the survey area. The map unit descriptions, along with the soil maps, can be used to determine the suitability and potential of a soil for specific uses, and, precautionary erosion and sedimentation control measures which must be adhered to. They also can be used to plan for the management needed for those uses. The profile of the soil classifications follows: Elloalk Loam (27B), 2 to 7 percent slopes: This deep, gently sloping, well -drained soil is on broad to narrow convex ridge tops. Typically, the surface layer is dark brown and reddish brown loam about eight (8) inches thick. The subsoil is about 41 inches thick. It is yellowish red silty clay loam and red silty clay in the upper part and red silt clay loam and silt loam in the lower part. The substratum to a depth of 72 inches is mottled strong brown, yellowish red, and reddish brown silt loam. Permeability is moderate, and available water capacity is moderate. Surface runoff is medium. The hazard of erosion is moderate. The subsoil has moderate shrink -swell potential. Depth to bedrock is usually greater than 5 feet. Elloak Loam (27C), 7 to 15 percent slopes: This deep, gently sloping, well -drained soil is on convex ridge tops and side slopes. Typically, the surface layer is dark brown and reddish brown loam about eight (8) inches thick. The subsoil is about 41 inches thick. It is yellowish red silty clay loam and red silty clay in the upper part and red silt clay loam and silt loam in the lower part. The substratum to a depth of 72 inches is mottled strong brown, yellowish red, and reddish brown silt loam. Permeability is moderate, and available water capacity is moderate. Surface runoff is medium. The hazard of erosion is moderate. The subsoil has moderate shrink -swell potential. Depth to bedrock is usually greater than 5 feet. Elioak Loam (27D), 15 to 25 percent slopes: This deep, moderately steep, well -drained soil is on side slopes. Typically, the surface layer is dark brown and reddish brown loam about eight (8) inches thick. The subsoil is about 41 inches thick. It is yellowish red silty clay loam and red silty clay in the upper part and red silt clay loam and silt loam in the lower part. The substratum to a depth of 72 inches is mottled strong brown, yellowish red, and reddish brown silt loam. Permeability is moderate, and available water capacity is moderate. Surface runoff is medium. The hazard of erosion is moderate. The subsoil has moderate shrink -swell potential. Depth to bedrock is usually greater than 5 feet. Gleneig Loam (34C), 2 to 7 percent slopes: This deep, strongly sloping, well -drained soil is on narrow convex ridge tops and on convex side slopes. Typically, the surface layer is dark brown and dark yellowish brown loam about eight (8) inches thick. The subsoil is mostly strong brown yellowish red silty clay loam and is about 20 inches thick. The sub -stratum is multicolored yellowish red, strong brown, and yellowish brown saprolite that crushes to loam. Permeability is moderate, and available water capacity is high. Surface runoff is rapid. The hazard of erosion is severe. The subsoil has low shrink -swell potential. Depth to bedrock is usually greater than 60 inches. Hazel Loam (39D), 15 to 25 percent slopes: This soil is moderately deep, excessively drained, and moderately steep. It is on narrow ridge tops and side slopes. Typically, the surface layer of this soil is dark brown and brown loam about 10 inches thick. The subsoil is about 10 inches thick and is brown loam. The substratum to a depth of 30 inches or more and is strong brown channery loam. Permeability is moderately rapid and available water capacity is low. Surface runoff is rapid. The subsoil has low shrink -swell potential. Depth to bedrock is generally 20 to 40 inches. CRITICAL AREAS No critical areas are foreseen at this time. EROSION AND SEDIMENT CONTROL MEASURES The contractor shall provide, construct and maintain erosion and sediment control measures on the site, in accordance with the Virginia Department of Transportation and the County of Albemarle erosion and sediment control measures (refer to the Erosion and Sediment Control Plan sheet). All vegetative and structural erosion and sediment control practices shall be constructed and maintained according to minimum standards and specifications of the Virginia Erosion and Sediment Control Handbook. Permanent or temporary soil stabilization shall be applied to denuded areas within seven (7) days after final grade is reached on any portion of the site. Temporary soil stabilization shall be applied within seven (7) days to denuded areas that may not be at final grade but will remain dormant (undisturbed) for longer than 30 days. Permanent stabilization shall be applied to areas that are to be left dormant for more than one year. Soil stabilization refers to measures that protect soil from the erosive forces of raindrop impact and flowing water. Applicable practices include vegetative establishment, mulching, and the early application of gravel base on areas to be stone. Soil stabilization measures should be selected to be appropriate for the time of the year, site conditions, and estimated duration of use. Temporary sediment filters and traps, perimeter dikes, sediment barriers and other measures intended to retain sediment shall be constructed as a first step in any land -disturbing activity and be made functional before up slope land disturbance takes place. Stabilization measures shall be applied to earthen structures such as dams, dikes and diversions immediately after installation. The following structural practices will be implemented according to the requirements set forth by the Virginia Erosion and Sediment Control. a). Safety Fence (3.01) A protective barrier consisting of polyethylene web secured to a conventional metal post driven into the ground a minimum of 18 inches. Posts should be spaced at 6-foot centers. Used to prevent undesirable use of an erosion control measure by the public. To prevent access to an erosion control measure. Speck Application: Safety fence will be used at areas where pedestrians may come into contact with the planned work. The Contractor shall consult with the Director of Facilities for the Covenant School prior to start of work for exact limits of safety fence throughout the project. P1. Temporary Stone Construction Entrance (3.02) A seventy (70) foot stone section shall be installed at the point of vehicular ingress and egress on the construction site. This stone area shall be used for washing sediment from vehicles exiting the site. Where sediment is transported onto a public road surface, the road shall be cleaned thoroughly at the end of each day. Sediment shall be removed from the roads by shoveling or sweeping and transported to a sediment control disposal area. Street washing shall be allowed only after sediment is removed in this manner. Specific A construction entrance shall be positioned to utilize the existing gravel access drive directly adjacent to the utility shed location. Additional gravel shall be applied if the Erosion Control Inspector deems it necessary. If doomed necessary by the County Inspector the temporary stone construction entrance shall be converted into a temporary paved construction entrance. c)). Silt Fence (3.05) A temporary sediment barrier consisting of synthetic filter III stretched across and attached to supporting posts and entrenched. Used to prevent sediment from leaving the site. To decrease the velocity of sheet flows. Specific Application: Silt fence shall be used as necessary or as directed by the Erosion Control inspector or where shown on the plan. �J. Inlet Protection (3.07) A temporary sediment filter around a storm inlet or curb inlet, in order to prevent sediment from entering storm drainage systems prior to permanent stabilization of the disturbed area. Specific Application: Inlet protection will be used around all storm drainage inlets and curb inlets existing within the project area and as shown on the plan. e). Temporary Seeding (3.31) The establishment of a temporary vegetative cover on disturbed areas by seeding with appropriate rapidly growing annual plants. This protects slopes exposed during construction until permanent vegetative cover can be established. Specific Application Temporary seeding shall be used on all disturbed areas. D. Permanent Seeding (3.32) Establishment of perennial vegetative cover by planting seed on rough -graded areas that will not be brought to final grade for a year or more or where permanent, long-lived vegetative cover is needed on fine -graded areas. Specific Application: Permanent seeding will be applied to the disturbed areas. g). Dust Control (3.39) Reducing surface air movement of dust during land disturbances, demolition or construction activities in areas subject to dust problems in order to prevent soil loss and reduce the presence of potentially harmful airborne substance. ''IFTITITITTIRIT 111 11111 1111111111111 11 ilil I I III I I I 4;III I 111!111;� ♦E3�� PERMANENT STABILIZATION All areas disturbed by construction will be stabilized with permanent seeding immediately following finish grading. All seeds will be approved by the "Virginia Crop Improvement Association," Blacksburg Virginia. Seeding will be done with the following: Two (2) parts Kentucky Bluegrass (Poa pratensis), by weight; minimum 98 % purity and 90% germination; maximum 1 % weed seed. Three (3) parts perennial Ryegrass (Labium perrene) by weight; minimum 85% purity and 90% germination; maximum I % weed seed. Fifteen (15) parts Falcon Fescue; minimum 98% purity and 90% germination; maximum I % weed seed. Permanently seeded areas shall be protected during establishment. Mulch shall consist of oat or wheat straw, free from weeds, foreign matter detrimental to plant life, and dry. Hay or chopped cornstalks will not be permitted. Mulch and/or lime shall be applied at a rate of two (2) tons per acre. Specifications for fertilizer are FS 0-F-241 C, Type 1, solid form; Grade A or B, recommended for grass, with one hundred (100) percent of the elements derived from organic sources of the following properties: a) Nitrogen 12.0% b) Phosphoric Acid 8.0% c) Soluble Potash 8.0% With at least fifty (50) percent of the nitrogen from a non -water soluble organic source. The following measures shall be incorporated during fertilization: Apply fertilizer at a rate of 1000 lbs./acre. Apply after smooth raking of topsoil. Do not apply fertilizer at same time or with same machine as will be used to apply seed. Till fertilizer into upper two (2) inches of topsoil. Lightly water dry topsoil to depth of six (6) inches at least forty-eight (48) hours prior to seeding to obtain a loose friable seed bed and to aid in the dissipation of fertilizer. The following rates and practices will be adhered to for all seeding that occurs on -site: Apply seed a rate of 6-lbs./1000 sq. ft. evenly at right angles with a spreader or seeding machine. Rake in lightly, covering seed to depth of 1/8 inch. Do not seed area in excess of that which can be mulched on same day. Do not sow immediately following rain, when ground is too dry, or during windy periods. Roll seeded area with roller not exceeding 112 lbs. Immediately following seeding and compacting apply mulch to a thickness of one (1) inch. Maintain clear of shrubs and trees. Apply water with a fine spray immediately after each area has been mulched. Saturate to six (6) inches of soil. MAINTENANCE All erosion and sediment control measures must be maintained and repaired immediately to insure continued performance of their intended functions as stated in the Virginia Erosion & Sediment Control Handbook, Third Edition 1992. In general, all erosion and sediment control measures will be checked weekly and after each runoff -producing rainfall event. All seeded and sodded areas will be checked regularly to ensure that a good stand is maintained. Areas will be fertilized, reseeded and resodded as needed. DISPOSITION OF TEMPORARY MEASURES All temporary erosion and sediment control measures, including the temporary sediment basins, shall be removed within 30 days after final site stabilization is achieved or after the temporary measures are no longer needed, unless otherwise authorized by the local program administrator. Trapped sediment and other disturbed soil areas resulting from the disposition of temporary measures shall be permanently stabilized to prevent further erosion and sedimentation. E-3 (IIIIII kliky/A 1114 _.1,I 1! FACI W, f4i" 11111, The site is served by existing biofilters. Careful consideration shall be implemented to ensure that siltation does not compromise these structures. A gravel diaphragm shall be utilized to pretreat new drainage flowing into the existing biofilter. Covenant Upper School Final Site Plan: Erosion & Sediment Control Plan The County of Albemarle, Virginia ES-1: The plan approving authority must be notified one week prior to the pre -construction conference, one week prior to the commencement of land disturbing activity, and one week prior to the final inspection. ES-2: All erosion and sediment control measures will be constructed and maintained according to minimum standards and specifications of the Virginia Erosion and Sediment Control Handbook and Virginia Regulations VR 626-02-00 Erosion and Sediment Control Regulations. ES-3: All erosion and sediment control measures are to be placed prior to or as the first step in clearing. ES-4: A copy of the approved erosion and sediment control plan shall be maintained on the site at all times. ES-5: Prior to commencing land disturbing activities in areas other than indicated on these plans (including, but not limited to, off -site borrow or waste areas) the contractor shall submit a supplementary erosion control plan to the owner for review and approval by the plan approving authority. ES-6: The contractor is responsible for installation of any additional erosion control measures necessary to prevent erosion and sedimentation as determined by the plan approving authority. ES-7: All disturbed areas are to drain to approved sediment control measures at all times during land disturbing activities and during site development until final stabilization is achieved. ES-8: During dewatering operations, water will be pumped into an approved filtering device. ES-9: The contractor shall inspect all erosion control measures periodically and after each runoff -producing rainfall event. Any necessary repairs or cleanup to maintain the effectiveness of the erosion control devices shall be made immediately. ES-10: All fill material to betaken from an approved, designated borrow area. ES-1 1: All waste materials shall be taken to an approved waste area. Earth fill shall be inert materials only, free of roots, stumps, wood, rubbish, and other debris. ES-12: Borrow or waste areas are to be reclaimed within 7 days of completion per Zoning Ordinance section 5.1.28. ES-13: All inert; materials shall be transported in compliance with section 13-301 of the Code of Albemarle. ES-14: Borrow, fill or waste activity involving industrial -type power equipment shall be limited to the hours of 7:00am to 9:00pm. ES-15: Borrow, fill or waste activity shall be conducted in a safe manner than maintains lateral support, or order to minimize any hazard to persons, physical damage to adjacent land and improvements, and damage to any public street because o slides, sinking, or collapse. ES-16: The developer shall reserve the right to install, maintain, remove or convert to permanent stormwater management facilities where applicable all erosion control measures required by this plan regardless of the sale of any lot, unit, building or other portion of the property. ES-17: Temporary stabilization shall be temporary seeding and mulching. Seeding is to be at 75 lbs/acre, and in the months of September to February to consist a 50/50 mix of Annual Ryegrass and Cereal Winter Rye, or in March and April to consist of Annual Rye, or May through August to consist of German Millet. Straw mulch is to be applied at 80lbs/1008f. Alternatives are subject to approved by the County erosion control inspector. ES-18: Permanent stabilization shall be lime and fertilizer, permanent seeding, and mulch. Agricultural grade limestone shall be applied at 90lbs/1 000sf, incorporated into the top 4-6 inches of soil. Fertilizer shall be applied at 1 000lbs/acre and consist of a 10-20-10 nutrient mix. Permanent seeding shall be applied at 180lbslacre and consist of 95 % Kentucky 31 or Tall Fescue and 0-5% Perennial Ryegrass or Kentucky Bluegrass. Straw mulch is to be applied at 80lbs/100sf. Alternatives are subject to approved by the County erosion control inspector. ES-19: Maintenance: All measures are to be inspected weekly and after each rainfall. Any damage or clogging to structural measures is to be repair immediately. Silt traps are to be cleaned when 50% of the wet storage volume is filled with sediment. All seeded areas are to be reseeded when necessary to achieve a good stand of grass. Silt fence and diversion dykes which are collecting sediment to half their height must be cleaned and repaired immediately. ES-20: All temporary erosion and sediment control measures are to be removed within 30 days of final site stabilization, when measures are no longer needed, subject to approval by the County erosion control inspector. Meters 0 50 100 200 300 —Feet 0 200 400 Soo 1,200 U6 Dp� Natural Resources Web Soil Survey 2-0 M conervation emice National Coopefative, 30 Survey KEY 27B .................................... ELIOAK LOAM 27C .................................... ELIOAK LOAM 27D .................................... ELIOAK LOAM 34C .................................... GLENELG LOAM 39D ....................................HAZEL LOAM WooLLEYENGINEERING Consulting Civil Engineers 220 East high Street Charlottesville -Virginia 22902 (434)973.0045 www.Woolley-Eng.com- M€I � Chxbttesvffle, VA 22902? The Covenant School 175 Flickory Street Charlottesville, Virginia 22902 P: (434) 220-7329 Job Number: 1850 Date: January 31, 2019 Revision: April 29,2019 copyright @ 2019 by Woolley Engineering vic of, 11am'-1 Fie CONSTRUCTION ENTRANCE 0 DUST CONTROL ,.U�P INLET PROTECTION US PERMANENT SEEDING SAF SAFETY FENCE SF SILT FENCE QS TEMPORARY, SEEDING DRAINAGE DIVIDES-, - -;O"*'LIMITS OF DISTURBANCE copyright a 2019 by Woolley Engineering Owner: The Covenant School 175 Hickory Street Charlottesville, Virga 22902 P: (434) 220-7329 EROSION & SEDIMENT CONTROL PLAII Job Number: 1850 Date: January 31, 2019 BLOCK & GRAVEL CURB INLET IP STONE CONSTRUCTION ENTRANCE SEDIMENT FILTER WOOLLEY E, NGiNEERiNG CURB INLET Consulting Civil Engineers 220 East High Street ,.--� �'--��-,F TEMPORARY SAFETY FENCE Charlottesville - Virginia 22902 (434)973-0045 CD www.Woolley-Eng.com 70' MIN. ®, HYLE E B CONVENTIONALPOLYETRIC METAL IT) OR (ATTACH TO POSTS WITH METAL (U) j M x VI v- WIRES POSTS ) n DESIG APEARC LANDIK _11M;'�( SIDE ELEVATION -TE ii"A 2219112 , WIRE SCREEN CONCRETE BLOCK GRAVEL FILTER 6-0" MIN EXISTING GROUND Owner: The Covenant School 75 11 cko Street Charlottesville, 2 tteglle, Virginia do 70' MIN, 22902 RUNOFF WATER WITH OVERFLOW SEDIMENT GRAVEL 101* EDGE OF EX. DRIVEWAY 4SHRACR- A — P: (434) 29-0-7329 18" MIN FILTERED WATER 7� ,7- 11 it. M 6-1" MAX IT MR1 11 Iu ILL" ML14L 4 Eli Jr MOTE. CONTRACTOR MAY SUBSTITUTE TEMPORARY CHAIN -LINK FENCE WHERE APPROPRIATE. GATES AND OPENINGS SHALL BE FULLY COORDINATED WITH THE OWNER PRIOR TO INSTALLATION, A SEDIMENT CURB INLET PLAN V IA/ WIRE SCREEN 2" X 4" WOOD STUD 7- wADD TO EXISTING GRAVEL AS SPECIAL APPLICATION DIRECTED BY COUNTY > THIS METHOD OF INLET PROTECTION IS APPLICABLE AT CURB INLETS WHERE AN INSPECTOR L.0 OVERFLOW CAPABILITY IS NECESSARY TO PREVENT EXCESSIVE PONDING IN Oe FRONT OF THE STRUCTURE. < LU 12' MIN. Uj LL 0 V, K z 0 P SILT FENCE DROP INLET 'M 6" MINIMUM TEMPORARY SEEDING 9 1% 00 0 ki PROTECTION SE-CTION A —A Uj 2 x 4" WOOD FRAME ACCEPTABLE TEMPORARY SEEDING PLANT MATERIALS PLANTING DATES SPECIES RATE (lbs./acre) 7' SEPT. I - FEB. 15 50/50 MIX OF ANNUAL RYEGRASS 1,5' MAX, (Lolium muffifibrum) -c, z, V & 50-100 CEREAL (WINTER) RYE (Secale cereale) FEB. 16 - APR. 30 ANNUAL RYEGRASS 60-100 (Loliummuffifibrum) E&SC R Z 611"D MAY I - AUG. 31 GERMAN MILLET 50 ftalica) DETAILS �� F SILT FENCE (Seetaria 3' MIN Job Number: 1850 EXTEND FILTER STAKE DROP INLET STAKE WITH GRATE FABRIC INTO TRENCH It A A 15' I FRAME B R", FABRIC 4" ENV T. 'WOOMAY 4' LIC. NO. 3708V_,� R-I..... I BACKFILL AND COMPACT POINTS A SHOULD BE HIGHER THAN POINT B. THE EXCAVATED SOIL. 4�VIONAL s\/� iz g P1, A IONAL IONAL Aid GENERAL NOTES - SILT FENCE Date: January 31, 2019 -kl K ELEVATION OF STAKE AND GATHER EXCESS 1) The height of a silt fence Will be a minimum of 16 inches and a maximum of 34 inches Revision: FABRIC ORIENTATION AT CORNERS above ground elevation. F April 29,2019 2) Extra strength filter fabric shall be a continuous roll. When joints are unavoidable, a splice may be made at a support post with a 6" overlap. SPECIFIC APPLICATION 3) The excavated trench shall be 4 inches wide and 4 inches deep on the upslope side of the proposed location. THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE THE INLET DRAINS A RELATIVELY FLAT AREA (SLOPE NO GREATER 4) Support posts shall be a maximum of 10 feet apart where wire support is used, and no THAN 5%) WHERE THE INLET SHEET OR OVERLAND FLOWS (NOT more than 6 feet apart where wire is not used. When placing silt fence across a ditch Scale: EXCEEDING I C.F.S.) ARE TYPICAL. THE METHOD SHALL NOT APPLY TO INLETS RECEIVING CONCENTRATED FLOWS, SUCH AS or swale, the posts are to be set at a maximum 3' interval. As Noted IN STREET OR HIGHWAY MEDIANS. 5) The french shall be backfilled and the soil compacted over the filter fabric. 6) Silt fences shall be removed when the upslope area has been permanently stoblized. Sheet No.: ES3*V 16 of 16