Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ARB201900047 Plan - Revision 2019-06-25
FLOW AUTOMOTIVE MAZDA/ VOLKSWAGEN OF CHARLOTTESVILLE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 This submission includes 2 new automotive dealerships; which are separate entities but situated on adjacent properties at Pantops Corner of Route 20 & 250. The new Mazda Dealership will be located in the same location as the existing Mazda (1289 Stony Point Rd.); replacing the 1970's CMU block structure to be demolished. In its place, the new Mazda will provide all the amenities of a full -service dealership: an up-to-date showroom with wait- ing areas and offices, a vehicular drop off station as well as a new Service Bay Garage. While the new Mazda complex occupies a similar footprint as the old, it will provide a much -improved plan for both internal daily business operations as well as on the exterior increasing the efficiency of the site and improving its circulation. Just as important and related to the E.C. review, the new Showroom/Service Center will provide a much -need- ed upgrade from the existing - a somewhat dilapidated structure on an unimproved site. We see this project as an opportunity to enhance the character of the corner by improving the Site Plan with better organization and improved county recommended landscaping. And from an architec- tural standpoint, the project replaces the existing with a new building that addresses the corner and is more suitable to its prominent location. The current Mazda design standard is a contemporary style. Subdued with a simple combination of light and dark metal paneling, the exterior facade shows enough variety to create and maintain interest but not overly flamboyant so as to overwhelm the rest of the character on the corner or go against precedent on the 250 corridor. Large storefront windows are added to the facade which rounds out the material palette and provides a healthy amount of daylighting for the interior. Mazda's main design feature - referred to as 'the jewel box' - is a 2 story room enclosed in a glass frame that encourages one's gaze on the outside into the interior environment. This 'jewel box' seems an appropriate answer for addressing the Pantops Corner at this difficult site. Its prominent but well proportioned oversized glass wall is oriented toward the corner and enhances the impor- tance of its location. Further, the interior wall of the jewel box is lined with a wood plank the which forms a warm contrast to the exterior and materially ties into the local vernacular. The limitations of this particular site is an undeniable aspect of assessing both project plan layouts. As the diagrams on the following page illustrate, a major feature of the site is the established electric easement cutting across a large section of the south east corner; directly related to the large high voltage power lines overhead. Although many would agree in recom- B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com mending positioning the building's prominent corner (and jewel box) closer to the street edge, the easement has forced us to locate the building to- ward the rear of the site. You will also notice that the easement - in running diagonally across the site - pinches the southern portion. This circumstance along with the presence of steep slopes - shifts the Mazda building toward the north west section. Vehicular circulation is another major component limiting options on how the site might be laid with safe and efficient traffic flow. Engineering rec- ommendations for limiting entry to a shared access make the notion of efficient traffic flow paramount to this already tight, oddly shaped site. The current building plans strategically place the customer drop off garage as close as possible to the main road entry - which thereby reduces the amount of cars driving around the parking lot. In addition both dealer drop-off stations - which have to be adjacent to the showroom - are also situated where a more private drive connects the drop off to the service garage. The new VW complex (1311 Stoney Point Road) will provide the same full -service amenities as Mazda and is located on the next parcel down on the lot that currently includes the old Rexall building and also a smaller out -building to the north; both of which are slated for demolition. Other than the buildings mentioned above, the nature of this lot is mostly an old parking lot and overgrown vegetation. Unlike Mazda, which is oriented orthogonal to Rt. 250, VW orientation turns its front facade to run parallel to Rt. 20; helping to reinforce and maintain a street edge. With the electrical easement less of a constraint on this parcel, the major limitation is the site's long and skinny proportion. As with Mazda, the buildings orientation allows for immediate proximity from the Entry to vehicular drop-off as well as an efficient connector driveway from drop off zone to Service Bays. As with Mazda, the entry to the Service Bays are hidden/screened from site by the main building. As with Mazda, this particular site layout is advantageous in allowing for efficient daily operations and a plus for the Entrance Corri- dor in the way it limits the visual noise of constant visible moving vehicular traffic on site. While these projects will be under one ownership, as 2 unrelated corpora- tion on different parcels, they are considered separate projects. However, given their adjacency and location on an important corner of the En- trance Corridor; the county recommended studying them together given the impact they will ultimately have in the area. We look forward to work- ing with the county in providing the best possible design solutions. Ls PROJECT NARRATIVE FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 0 R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com Response Memo to County Recommendations Revise Forms, proportions, scale and materials to achieve greater balance of contemporary design with historic compatibility • VW - The following are changes made in response to the above recommendation: o Reducing Length of Front Fagade and in turn diminishing the front curtain wall. A major design revision was achieved by removing the Ser- vice Bay Doors from the main glass front fagade and pushing the entire Service Bay front back from the main fagade by 15'. This revision relates to the Design Guidelines by breaking down the building scale, reducing the sense of blankness of the original predominantly glass front facade, and fostering greater connection to the local historic fabric. o Numerous Material Changes: Both the addition of stone paneling replacing VW's white metal paneling and the addition of brick create a greater balance of contemporary with Historic compatibility. • Mazda - o Replacing all white metal paneling with Brick - A good deal of the original Mazda design included white metal paneling that we are now substituting for brick. o Addressed further breaking down the scale of the Service Bay block through material detailing. While the original design begins to break down the scale of the entire building by different 'sub-massses' , the Service Bay scale and proportion has been revised in this revision by bringing the new brick down to the corner. This move elimi- nates the stark contrast between the upper and lower half of this volume - which created a sense that the upper white sec- tion was floating - and in turn creates a sense of 'grounding'. In addition, the revised design articulates patterning through detailing reveals within the brick; which helps to break down and lend interest to the brick face. FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 2. Revise the architectural designs to use forms, features, materials and colors that are compatible with the forms and features of signif- icant historic buildings in the area. Consider brick or stone or other natural materials instead of metal panels. Consider revising the massing of the VW service drop-off. • VW o Per Board's recommendation, we revised the Service Drop off Bay - disenagaing it from the main front facade; thereby breaking down the scale of the overall structure. Now appearing as a smaller volume beside the larger show- room, this redesign is more in keeping with the local context by reducing the extent of the main glass facade and creat- ing a larger to smaller relationship that not only relates better to the surrounding historic structures but also to the Mazda design. o Stone - particularly limestone paneling - shall replace the orignal white metal paneling on the design main frames. o Brick is now being used as a secondary accent material ink cluding at the front elevation of the Service Bay. Adding a material more in keeping with the local building material palette. • Mazda o Brick shall replace all white metal paneling A major shift in the predominant building skin that brings the design more in line with the local context. 3. Provide Details proposed curtain wall • See included detail drawings 4. Clarify that the windows in the service wing use vision glass • Confirmed 5. Revise Design to emphasize human scale • VW o The new revised massing reduces the overall scale of the building by breaking it down to a major and minor volume; thereby moving from a more monumental design to one more in line with the human scale. o The Entry Portals within the Showroom glass facade help re- late the 2 story structure to the human scale and provide an instantly recognizeable entry element for the B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com pedestrian. Also the entry now clad in limestone - were reduced in size upon redesign. o The new material change provides a warmer, more tex- tured and sensory experience for the human scale. • Mazda o The Mazda Design breaks down the entire complex into a series of massings more in keeping with the human scale. o Although a 2 story space, the Mazda 'Jewel Box' is lined inside with a warm wood the that relates better to the human scale vs a colder ma- terial. o As with VW, the Mazda switch to a majority of exterior brick as a new material change provides a warmer, more textured and sensory experience for the human scale. 6. Revise Design to establish greater coordination with nearby buildings. • VW o With a change of materials - brick and stone - we are relating the new VW to the best precedents within the surrounding context. o The building's orientation on site also reflects the inten- tion of defining the street edge while also hiding the Service Bay volume to the rear of the site. 0 • Mazda o The reduction of a majority of the metal paneling. 0 White Brick - there are many examples of brick / stucco palette within the corridor. With the grey to white combination, we are striving for an elegant solution that on the other hand doesn't call too much attention to itself and fits well within the sur- rounding fabric. 7. Revise the Trademark Design to meet the EC Guidlelines o seepage 'Existing trademark Buildings for comparison imagery and further clarificaiton on how these particular designs depart from the standard trademarks. 8. Provide specificaiton on window Glass o glass to meet EC guildelines - sample can be provided if requested. 0 12. Standard Mech Equip. note placed on Architecturals 13. Eliminate the illumination trough from the design. o We request keeping illumintion trough with the condition that it be set on a timer per the County's regulation. 9.-30. Refer to SITE PLAN RESPONSE TO COUNTY COMMENTS FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 r►f existing VW site looking south east on RT 20 B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.9 71.7 160 www.brw-architects.com existing Mazda site looking north east on RT 20 r existing Mazda site looking south east on RT 20 SITE EXISTING PHOTOS FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 ill = 100'-0" PROPERTY LINE PROPERTY LINE bIN" RTA SEWER 5 --�\ ARY ELECTRICAL E�ASEME�T� � � � FRONTAGE ill" = 100'-0" B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971 . 7160 www.brw-architects.com PROPERTY LINE TOPOGRAPHIC 1 " = 100'-0" CONSTRAINTS SITE DIAGRAMS FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 PROPERTY LINE 2 F Building to be demolised I pRo 'OF Rryl/NF scale : 1 " = 50'-0" II building to demolised 1311 Stony Point RD i I Existing Mazda I1298 Stony Point Parking lot lST �lvYp T 20 � O�NTRo EXISTING SITE PLAN B R W A R C H I T E C T S 112 fourth street NE FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER charlottesville virginia 22902 ARB Submittal 434.971 ' 7160 www. brw-a rch itects.co m June 24, 2019 L scale : 1 " = 50'-0" B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971 . 7160 www.brw-architects.com BUILDING PLANS AND SITE CIRCULATION FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com EXISTING SITE PHOTO LOOKING NORTH EAST FROM RT. 250 INTERSECTION FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.9 71.7 160 www.brw-architects.com * selected landscape species are for illustration only LOOKING NORTH EAST FROM RT. 250 INTERSECTION FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 .. K - 4:a - a i .,y ....�`ap'E_-�•.c.el�,�.re.:-.Ji1F��.".Y'eiil:..FSI.e.'—..,. B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com EXISTING SITE PHOTO LOOKING EAST FROM RT. 20 FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.9 71.7 160 www.brw-architects.com * selected landscape species are for illustration only LOOKING EAST FROM RT. 20 FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 ti VE gyp. �rx. 0I0 WAI:■;F±Vl■alte B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com PERSPECTIVE - VEHICULAR ENTRY FROM RT. 20 FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com LOOKING EAST AT VW FRONT FACADE FROM RT. 20 FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com PERSPECTIVE LOOKING SOUTH EAST FROM RT. 20 FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 r v- — .*.a , '4 t t , —.-,. lwtp ♦ - - - - .t .,_�'�• wr„C All Ss E '�c r ti t i1r �' �, R;' K +.: • �,• i ' '� f :+�sut%-'�R. ,�. ` Or is 1*� : `'� �� ,r! ��Z� Y � it _; � ra "a ��^ Sa ,P '�1' �Y''�'y .i �' •„4�y� aY AOu a/�> -y. �p`r of •g �Y�y fy t �' y+' y ' , a lic lyM•�"�J , 1��.. "��:?Y `i l� , � , •f�:�%4 ��F�.%'� -4}"'.� �a'r-#r„�.t - F-r�` �a�.; Nt•. It. ! .. * ji s $fit r'} " • r FM � :' y 'e � �� �-•,s, tit'\-:�. '� � ry .'� w - w � ��ls tad. E y� �'+ 4' I� h , M-'Q ion r *Ind olra W* B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.9 71.7 160 www.brw-architects.com LOOKING NORTH EAST FROM RT. 250 FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 s M 1 6 p Sd ,.. ry SIDE ELEVATION FRONT ELEVATION MATERIAL CHANGE PER GUIDELINES DEALER FRAME WITH ILLUMINATED DEALER NAME SIGN STONE PANEL SP-1 CENTERLINE OF VW SIGNAGE ACM-1 #2 SERVICE FRAME WITH BRICK WALL - STONE PANEL SP-1 WITH BLACKLIT LETTERS BY VWoA SIGN VENDOR. SEE Ad.4 BUILDING FRAME ILLUMINATION TROUGH AT KLAYCOAT - SERVICE FRAME INTERIOR PERIMETER 'STONE GREY BY GLEN -EERY a (V U zo o_ ' - n / / \ REVISED DEALER NAMEPLATE FRAME- FOR INCREASED COMPATABILITY TO HUMAN B R W A R C H I T E C T S 112 fourth street NE charlottesville vi rgi nia 22902 434.971.7160 www.brw-architects.com BUTTJOINT CURTAIN WALL CLEAR ANOD. ALUM. CURTAIN WALL (CW-1) WITH CLEAR GLAZING (GL-1) RE: A7.12 108' - 6 1 /2" HOURS OF OPERATION SIGNAGE STONE PANEL SP-1 ENTRY FRAME WITH RE: TO DCD SHEET G3.0 CLEAR INSULATED GLAZING SYSTEM AND VW LOGO CLIP ON INTERIOR AND EXTERIOR FACES Note: Visibi ty of all mechanical equipment from the Entrance Corridor shall be eliminated VW - REVISED SERVICE BAY - RECESSED FRONT - RELATES TO GUIDELINES BY 1. BREAKING DOWN THE BUILDING SCALE 2. REDUCING'BLANKNESS' OF ORIGINIAL FACADE DESIGN scale : 3/32" = V-0" FRONT ELEVATION FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 stucco - light grey B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com MAN DOORS PAINT PT-7 (TYP.) brick accent ANGLED SIDE ELEVATION I SIDE ELEVATION O.H. DOORS PAINT PT-7 (TYP.) IF NO GLAZING STONE PANEL SP-1 BUILDING FRAME STONE PANEL SP-1 ENTRY FRAME WITH CLEAR INSULATED GLAZING SYSTEM AND VW LOGO CLIP ON INTERIOR AND EXTERIOR FACES CLEAR ANOD. ALUM. CURTAIN WALL (CW-1) WITH CLEAR GLAZING (GL-1) N f\ a SIGN VENDOR. SEE A7.11 scale : 3/32" = 1'-0" VW - NORTH ELEVATION FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 HIGHLY VISIBLE FROM EC. I BARELY VISIBLE FROM EC. _ JI VL VI JI IJINL JIVL VI JI\JIVL PANEL SP-1 PANEL SP-1 L.LL/YI[ YIV\JV. / LVIVI. L,URIYIIV VVF LL LJ RII..R VVf LL- - (CW-1) WITH CLEAR GLAZING (GL-1) STONE GREY' BY GLEN-GERY IVI!\IV VVVRJ F/ 1111 PT-7 (TYP.) Ilyl II yjl y V.fl. VVVRJ PAITN PT-7 (TYP.) IF BUILDING FRAME SERVICE FRAME RE: A7.12 NO GLAZING 0 I N b Jl� El EEI jzz o - 66' - 9 5/8" 34' - 9 5/8" 76' - 0 1 /4" SERVICE BAY 177' - 7 1 /2" B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com Note: VIsibI ty of all mechanical equipment from the Entrance Corridor shall be eliminated scale : 3/32" = 1 '-0" VW - SOUTH ELEVATION FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 LIMESTONE PANEL ACM METAL 2'-2" COPING PANEL COPING - 2'-2" Variable Variab T/O BUILDING FRAME_ �`� _ �� T/O BUILDING FRAME EL SEE A6.3 �EL: SEE A6.3 - --- n LIMESTONE PANEL cy LIMESTONE PANEL N TOREPLACEACM iV TO REPLACE ACM METAL PANEL\- I METAL PANEL` � I I LIMESTONE LIMESTONE PANEL SOFFIT- "rI J - PANEL SOFFIT __ LIGHT FIXTURE - -- -- - LIGHT FIXTURE _ HOUSING - - /'� / HOUSING LIGHT FIXTURE- N LIGHT FIXTURE LIGHT BOX LENS - -----'.. i 51 L7 P O L NST BOX MIN 1HD-1 SHD-1 SEE M22--- ---- $EE M22 LINE OF 'i LL LL CURTAIN WALL ,y N M LINE OF w w CURTAIN WALL - BY OTHERS - N N N - BY OTHERS N N N METAL GUTTERING SYSTEM W/ HORIZONTAL DOWNSPOUTS MULLION TOP OF FRAME (IF REQUIRED) - �EL. 15'-10' BUTTJOINT EL. 13'-21/12" �-� 'N DEALER NAME ,y SIGN W/ �o ACCESS PANEL DEALER NAME SIGN REAR ILLUMINATION BUTTJOINT BOTTOM OF FRAME OPENING lid EL. V-11 1/4" - - EL. 8'-31/2" LIMESTONE PANEL TO REPLACE ACM METAL PANEL LIGHT FIXTURE HOUSING LIGHT FIXTURE LIGHT BOX LENS N ti M LINE OF o cn CURTAIN WALL BY OTHERS - LINE OF CURTAIN S7a LINE OF WALL - BY OTHERS--- r� CURTAIN WALL - BY OTHERS N N N LIGHT BOX LENS LIGHT FIXTURE LIGHT FIXTURE 1-4 HOUSING LIMONE L REESTPANEL TO PLACE ACM METAL PANEL 4 BOTTOM OF FRAME _ _ _ _ BOTTOM OF FRAME_ _ a EL.O'_l" _ 7NE SHOWROOM SHOWROOMFINISH FLOOR EL.O-0" - FINISH FLOOR—�-�STONE ' STOLANDSCAPELANBORDER BO DRAINAGE SYSTEM- DRAINAGE SYSTEM - BYOTHERS------- BY OTHERS — Building 1 - Facade Section Frame B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com LIMESTONE PANEL TO REPLACE ACM METAL PANEL LIMESTONE PANEL TO REPLACE ACM METAL PANEL Buildin Dealer 1 - Facade Section Accent rame VW - CURTAIN WALL TYP. DETAILS FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 MATERIAL CHANGE PER GUIDELINES BRICK - WHITE (COLOR TO MATCH MP-2) 28' - 2" B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com 77' - 8'' MATERIAL CHANGE bl'-4" Note: Visibilty of all mechanical equipment from the Entrance Corridor shall be eliminated scale : 3/32" = V-0" MAZDA - FRONT ELEVATION FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 0 Ct N NORTH ELEVATION B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971 . 7160 www.brw-architects.com scale : 3/32" = 1 '-0" MAZDA - NORTH ELEVATIONS FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 WALL BEYOND MP-3 METAL PANEL - Black BRK-1 BRICK - BRICK COPING WALL BEYOND WHITE 0 M 0 d- o O N O i b �o o _ ' 0 18' - 6' 70' - 0" 88' - 6" SOUTH ELEVATION B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com Note: Visa i ty of all mechanical equipment from the Entrance Corridor shall be eliminated scale : 3/32" = 1 '-0" MAZDA - SOUTH ELEVATIONS FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 v B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com New development entrance Proposed FLOW Volswagen Showroom ELEMENTS OF ENTRY CORRIDOR GUIDELINES FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 Proposed FLOW Mazda Clean Machine Car Wash Compatibility with Significant Historic Sites Buildings should relate to their site and surrounding context Both dealerships utilize a contemporary design that prioritized a clean- ess of geometry that one would assiciate with our historic structures. The simplicity of the glass and metal paneling puts a focus on materiality of the facade and again avoids the fussiness that is contrary to our historic context. B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com Both buildings seem to fit within the wide range of structures located at the intersection. Buildings should have a human scale Both Dealerships provide a strong sense of entry and scaling mecha- nisms that deal with human scale in that they allow people to relate to the scale of the complexes in a personal way. Compatibility with the Character of the Entrance Corridor The size and scale of this building compares appropriately with the size and scale of buildings on both sides of the Entrance Corridor. It would fall into the moderate range in comparison to other buildings in the area. The Entrance Corridor along US 250 east of Charlottesville at Pantops represent a diversity of architectural approaches to design and scale. Stylistically, both dealerships appear to fit within this wide range of styles and one may argue enhances the Corridor with their well detailed design standards. Both Dealerships suggest a contem- porary design with simple yet varied materials; that leads to a classical elgance through their simplicity. Further one might argue that both de- signs provide visual interest while avoiding the 'overly fussy' that often lead to a lot of visual noise in high traffic areas. The Appearance of Blankness Should be relieved using details or vegetation The Site Plan shows a good deal of improvement in regards to the Landscaping. While the electric easement limits not only building placement but also the variety of tree we can use (it has to be a smaller understory), our proposed landscape shows a multi -layered tree layout (using native species) that both strengthens street edge but also creates a buffer at this busy intersection. Form, Shape, Scale, and Material Creating a Cohesive Whole The two dealerships deal with the idea of form and shape in different ways but both provide designs that allow for a massing and compos- tion appropriate to the Entrance Corridor. Mazda breaks its facade down into a variety of forms and emphasiozes priority of function through a series of diffierent sized masses. Materiality and the variety of major and minor shapes help tie the overall composition together. This strategy breaks down the overall scale of the building and avoids the monotony and blankness on less successful designs. On the other hand, VW maintains a design that is more singular and its scale ius broken down by the various portal or gates the denote Entry and the other major functions of the dealership. As a whole, the VW design seems to work as a simple, framed box that is well detailed and again emphasizes a contemporary simplicity. ELEMENTS OF ENTRY CORRIDOR GUIDELINES FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 B R W A R C H I T E C T S 112 fourth street NE charlottesville virginia 22902 434.971.7160 www.brw-architects.com :I oe F:7�1 .... diP From left: Palm Springs, CA; Surrey, BC; Raleigh, NC; Corpus Christi, TX Note: Charlottesville VW Design proposal derviates from these typical Prototypes in the following ways: - White metal paneling replaced with Stone - Service Bay recessed from Main Front Facade, breaking down the scale of Front Facade - Brick replace metal as main accent material. - Overall building layout revised to better suit this particular site; providing a strong building edge along route 20. Note: Charlottesville Mazda Design proposal derviates from these typical Prototypes in the following ways: From left: Orlando, FL; Schrewsbury, NJ - White metal paneling (the majority of the standard design) replaced with Brick. - Jewel Box reoriented to fit this particular site and work with its limitations. - The Service Bay Garage redesigned to better fit local context and this particular site: - Brick runs down at corner (and breaks the standard rule of white on top and black on bottom) to better address the main street corner. - Windows and Metal infill paneling between windows enhances visual interest at Service Bay Garage given it's prominent location. Typical design standards show these areas are most often covered in stucco and maintain the upper and lower black and white color palette. EXISTING TRADEMARK BUILDINGS FLOW MAZDA/ VOLKSWAGEN AUTOMOTIVE SHOWROOM & SERVICE CENTER ARB Submittal June 24, 2019 INITIAL SITE DEVELOPMENT PLAN LEGEND EXISTING NEW 10 10 1.00' - 31� 10 12 311.' 578X 11.5 TC 578X� _,11. 5 TW 57aX 11.5 B W 578XWZEN a d a f 0 0 0 DESCRIPTION boundaries BENCHMARK SITE PROPERTY LINE ADJACENT PROPERTY LINE VACANT PROPERTY LINE BUILDING SETBACK PARKING SETBACK ACCESS EASEMENT site text NOTES PARKING COUNT DIMENIONS ground GRADING EASEMENT INDEX CONTOUR INTERVAL CONTOUR SPOT EVELVATION TOP OF CURB ELEVATION TOP OF WALL ELEVATION BOTTOM OF WALL ELEVATION RETAINING WALL STAIRS building BUILDING ROAD -EDGE OF PAVEMENT ROAD- CENTERLINE ROAD -FRONT OF CURB ROAD BACK OF CURB CG-2 STANDARD 6" CURB CG-6 STANDARD 6" CURB AND GUTTER CG-12 STANDARD ACCESS RAMP SIDEWALK BIKE PARKING PARKING SURFACE CROSSWALK HANDICAP ACCESSIBLE AISLE HANDICAP PARKING material CONCRETE/PAVEMENT-SIDEWALK RI PRAP ASPHALT GRASS EC-3 MATTING EC-2 MATTING WETLAND TREELINE FENCE STREAM utility UTILITY EASEMENT UTILITY POLE LIGHT POLE OVERHEAD UTILITY MANHOLE sanitary & sewer STORM LINE ROOF DRAIN DRAIN INLET DRAINAGE EASEMENT STORM DRAINAGE EASEMENT STORM SEWER EASEMENT SEWER LINE SANITARY EASEMENT water WATER LINE WATER METER WATER VALVE AND BOX FIRE HYDRANT WATER EASEMENT gas GAS LINE OWNER/DEVELOPER Flow 1289 Stony Point LLC, c/c Flow Companies LLC 1425 Plaza Drive Winston Salem, NC 27103 ZONING TMP 78-5C. 78-513 HC-Highway Commercial EC- Entrance Corridor Front minimum = 10 FT from right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way. Front maximum = 30 FT from right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way. Side/Rear lots zoned Highway Commercial = primary structure shall be constructed and separated in accordance with the current edition of the Building Code. No maximum Side/Rear setback. Off-street parking and loading setbacks Minimum off-street parking/loading front setback = 10 feet from any public street right-of-way. Minimum off-street parking/loading setback side and rear setbacks = no off=street parking or loading space shall be located closer than 20 feet to the district boundary. DISTRICT Rivanna SOURCE OF TITLE DB 4873/577 SOURCE OF BOUNDARY AND TOPOGRAPHY Boundary & topographic survey provided by: Roudabush BENCHMARK Datum for topography is NAVD 88 FLOODZONE According to the FEMA Flood Insurance Rate Map, effective date February 4,2005 (Community Panel 51003CO287D), this property does not lie in a flood plain. RESERVOIR WATERSHED This site is within the Upper Rivanna River Watershed. This site is not within a watershed of a public water supply. WATER & SANITARY SERVICES Site is served by Albemarle County Service Authority. GENERAL CONSTRUCTION NOTES 1. Prior to any construction within any existing right-of-way, including connection to any existing road, a permit shall be obtained from the Virginia Department of Transit (VDOT). This plan as drawn may not accurately reflect the requirements of the permit.Where any discrepancies occur the requirements of the permit shall govern. 2. All materials and construction methods shall conform to the current specifications and standards of VDOT unless otherwise noted. 3. Erosion and siltation control measures shall be provided in accordance with the approved erosion control plan and shall be installed prior to any clearing, grading or other construction. 4. All slopes and disturbed areas are to be fertilized, seeded and mulched. 5. The maximum allowable slope is 2:1 (horizontle:vertical). Where reasonably obtainable, lesser slopes of 3:1 or better are to be acheived. 6. Paved, rip -rap or stabilization amt lined ditch may be required when in the opinion of the County Engineer or designee it is deemed necessary in order to stabilize a drainage channel. 7. All traffic control signs shall conform with the Virginia Manual for Uniform Traffic Control Devices. 8. Unless othrewise noted all concrete pipe shall be reinforced concrete pipe - Class III. 9. All excavation for underground pipe installation must comply with OSHA Standards for the Construction Industry (29 CFR Part 1926). GENERAL WATER & SEWER NOTES 1. Work shall be subject to inspection by Albemarle County Service Authority inspectors. The Contractor will be responsible for notifying the proper service authority officials at the start of the work. 2. The location of existing utilities across the line of the proposed work are not necessarily shown on the plans and where shown, are only approximately correct. The contractors shall on his own initiative locate all underground lines and structures as necessary. 3. All materials and construction shall comply with the current edition of the general water and sewer construction specifications as adopted by the Albemarle County Service Authority. 4. Datum for all elevations shown in National Geodetic Survey. 5. The contractor shall be responsible for notifying "MISS UTILITY" (1-800-552-7001). 6. All water and sewer pipes shall have a minimum of 3.5 feet of cover measured from the top of pipe, over the centerline of pipe. This includes all fire hydrant lines, service laterals and water lines, etc. 7. All water and sewer appurtenances are to be located outside of roadside ditches. & Valves on deadend lines shall be rodded to provided adequate restraint for the valve during a future extension of the line. 9. Trees are not permitted in the ACSA easement. 10. The contractor shall be responsible to comply with the no -lead regulation regarding brass fittings effective January 4, 2014 (Senate Bill 3874 which amends the Safe Drinking Water Act). 11, All public water and sewer facilities shall be dedicated to the Albemarle County Service Authority. 12. Backflow prevention is required for all connections to the water main. VDOT NOTES VDOT's land development south staff (540-967-3715 or 540-967-3716 shall be notified 48 hours in advance of any anticipated road/shoulder closures", "The permittee or his or her designee shall report all work zones in the VDOT right of way on a daily basis at set up and take down to VDOT'S Smart Traffic Center (540-332-9500)", "Copies of all independent testing reports to be submitted to VDOT for verification", "A minimum 48 hours advance notification of a proof roll of both the subgrade and stone base is required by VDOT.""AII areas excavated below existing pavement surface and within clear zone, at the conclusion of each workday, shall be backfilled to form an approximate 6:1 wedge, against the existing pavement surface for the safety and protection of vehicular traffic."And that "Traffic shall be maintained during construction of the tie-in and mill of the adjacent travel lanes." "water lines, sewer lines, etc. crossing future VDOT maintained roads have to be sleeved with ductile iron pipe "two (2) times diameter of the utility line)."And "A video (3 electronic copies to VDOT) of all stormwater systems carrying VDOT runoff or runoff under a future state road is required to be submitted to VDOT for review and approval prior to paving operations. ITE Trip Generation AM PM Use Description ITE SF in out Total in out Total Auto Dealership 1 840 15,514 19 17 36 22 26 48 Auto Dealership 2 1 840 10,877 14 13 27 17 20 37 Total 26,391 63 1 1 85 FLOW MAZDA / VW BUILDING HEIGHTS Maximum Allowable: 60' Maximum Proposed: 25' BUILDING SETBACKS 40' Setback from internal Commercial and Industrial Subdivision Streets 10' Setback from adjacent commercial and industrial uses EXISTING USE 1,952 SF Auto Dealership PROPOSED USE 2 new auto dealerships including showroom, drop off and service areas. 1) Volkswagon combined 15,514 SF 2)Mazda combined SF 10,877 SF Maximum Disturbed Area: 1.24 AC LAND USE SCHEDULE EXISTING Area % Building 17,371 SF 15.3% Pavement 51,671 SF 45.4% Sidewalk 0 SF 0% Open Space 44,649 SF 39.3% Total= 113,691 SF (2.61 ac.) PROPOSED Area IN. Building 23,391 SF 14.6% Pavement 51,324 SF 12.7% Sidewalk 2,453 SF 0.3% Open space 36,523 SF 72.4% Total= 113,691 SF (2.61 ac.) PARKING SCHEDULE Required Parking: Sales - 1 space per 1,500 SF display area 15,552 SF display / 1,500 SF = 11 customer spaces 11 customer spaces (4 accessible spaces provided) Services - 1 employee space + 2 additional spaces per service stall 17 stalls: 17 employee spaces + 34 customer spaces = 51 spaces 17 employee spaces + 34 customer spaces (4 accessible spaces provided) Total Parking Required = 62 Total Parking Provided = 92 (NOT INCLUDING DISPLAY) SIGNS All signs and pavement shall conform with the latest edition of the MUTCD Guidelines. A sign permit must be issued in accordance with the Louisa County Sign Regulations prior to placement of any signs on -site. Contractor shall provide handicap signs as shown on plan. GENERAL NOTES 1. The information ana data shown or indicated with respect to the existing underground utilities at or contiguous to the site are based on information and data furnished to the owner and engineer by the owners of such underground facilities or others. The owner or engineer shall not be responsible for the accuracy or completeness of such information or data. The contractor shall have full responsibility for confirming the accuracy of the data, for locating all underground utilities, for coordination of the work with owners of such underground utilities during construction, for the safety and protection thereof and repairing any damage thereto resulting from the work. All of these conditions shall be met at no additional cost to the owner. The contractor shall contact "Miss Utilities" of Virginia at 1-800-552-7001 prior to the start of work. 2. When working adjacent to existing structures, poles, etc., the contractor shall use whatever methods that are necessary to protect structures from damage. Replacement of damaged structures shall be at the contractor's expense. 3. The contractor shall be responsible for protecting all existing site structures from damage and coordinating work so that the owner can make necessary arrangements to modify/protect existing structures from damages. 4. The contractor shall be responsible for notifying all utility owners, adjacent land owners whose property may be impacted and the Virginia Department of Transportation prior to completing any off -site work. 5. Contractor shall notify and coordinate all work involving existing utilities with utility owners, at least 72 hours prior to the start of construction. 6. Contractor shall immediately report any discrepancies between existing conditions and contract documents to the owner and engineer. 7. Contractor shall submit for the approval of the owner submittals of all specified materials listed in the plans, to include shop drawings, manufacturer's specifications and laboratory reports. the owner's approval of submittals will be general and will not relieve the the contractor from the responsibility of adherence to the contract and for any error that may exist. 8. All bare areas shall be scarified, limed, fertilized, seeded and mulched. 9. All trees, saplings, brush, etc. shall be removed from within the right of way and the drainage easements. 10. Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 1 1. Retaining walls require separate building permits. 12. All water service lines, sanitary laterals, and sprinkler lines must be visually inspected by the Albemarle County Building Department from the main to the structure. TAX MAP 78, PARCELS 5C & 5G ALBEMARLE COUNTY, VIRGINIA VICINITY MAPSCALE : 1"=2000' McIntire Park 33 FRANKLIN t -c V LOCUST . y. m� t = Dadeo Towe Park Ryan Homes at Cascadia Gx,e CraFtsman He+nex ilr Schenk's .ir.ROSE HILL Ceaenway ` �9 cs Ao9olane Aulo Parts A � nore Apartments LP'4 NORTH E 0 Hada's Hayek DOWNTOWN `^"` arPy�.r¢ Co �Sr o SITE FONTANA •..,x„.. / J ni,P rde 1.�, l . Q�Mr. GVFtey Art CenterA aav°' fN:rlla+Tee ©Tip Top 9 ParnoPs Shopping Center `ate ERR HILL Downtown Ma'lp e Appl¢6¢e'e .r,ll r 5ar NIARTHA aLL _ z JEFFERSONir'° ^�, CARRIAGE .ui h Strc, t 8:r-awe-ry Q HILL CONDOS z(Twi '.WJ Chimi kA ChariZs•t.tesvflle a Friendship Coup a "•° o _ COTTAGES P Apa.ttmenls,� Made Park - J E F F E R S O N r rs a M1 HTS, CONDOS Q River ew Cemetery The I -al Pe*rRon l�7y OVERLOOK Ili CONDOS ,edlr�® - n�� a•4w��.= c Paul ,x°nlara Martl'la c w r,m H-pltel1-9 - BEtM ONT r Map provided by Google.com SHEET INDEX C1 COVER C2 EXISTING HIMP C3 SITE PLAN ENGINEERING C4 GRADING PLAN LAND PLANNING -PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 C 5 EASEMENT PLAN CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM C6 LANDSCAPE PLAN C7 SITE DETAILS APPROVALS Current Development Planner Date Current Development Engineer Date Architectural Review Board Date Fire Official Date Building Official Date Albemarle County Service Authority Date Virginia Department of Transportation Date �AV -ALTH OF� o �1 o J � v JUSTI�o. SHIMP 45183 � A!SS101VAL � 0 ���I INITIAL SITE DEVELOPMENT PLAN ALBEMARLE COUNTY, VIRGINIA FLOW MAZDA / VW SUBMISSION: 2019.04.15 REVISION: FILE NO. COVER SHEET C1 of 6 19.020 Trip generation reflects AM and PM peak hour traffic. C 11 SHIM ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM IF ��ALTH °F v JUSTIHIMP a 45183 IONAL INITIAL SITE DEVELOPMENT PLAN ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2019.04.15 REVISION: FILE NO. o � 19.020 EXISTING & DEMO PLAN i�� \ SHEET C2 of C7 30 0� 30 60 90 Scale: 1 "=30' �. SHIM ENGINEERIN 32 LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM p,LTH Op ' O o � v JUST�HIMP a 45183 ' 1-6 O w� ' SjONAL SDN INITIAL SITE DEVELOPMENT PLAN ALBEMARLE COUNTY, VIRGINIA FLOW MAZDA / VWI SUBMISSION: 2019.04.15 REVISION: FILE NO. SITE PLAN SHEET C3 of C7 19.020 C3 o� I I I 1 1 20 0 \ 20 Scale: 1 "=20' m SHIM ENGINEERIN 32 LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434,227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM ���ALTH 0, O J v JUST �HIMP a 45183 V� IONAL E�C'1 INITIAL SITE DEVELOPMENT PLAN ALBEMARLE COUNTY, VIRGINIA FLOW MAZDA / VW SUBMISSION: 2019.04.15 REVISION: FILE NO. GRADING PLAN ,I SHEET C4ofC7 60 19.020 C4 (EY No Medium or Large Trees 0 o Shrubs Only 7 o 0 CHIMP NGINEERING! ID PLANNING - PROJECT MANAGEMENT !::::!A E. HIGH ST. 434.227.5140 \RLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM N,LTH Op O v JuS i1viP a ]183 � � w� SjONAL IITIAL SITE DEVELOPMENT PLAN _BEMARLE COUNTY, VIRGINIA :LOW MAZDA / VW MISSION: 019.04.15 VISION: LE NO. ASEMENT PLAN BEET C5 of C7 19.020 C5 LL ERVICE SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE 4 S VICE 1 .01 ' 10 \ E PLOYEE �10.00' �� �MPLOYEE 2-G. G+ MPLOYEE 10.0 0' w Q 8 00' PL EE EMPYEE YE MPLOYEE EMPLOYEE EMP YEE EMPLOYEE EMPLOYEE EMPLOYEE S� DISPLAY \ EMPLOYEE 6 • w • DISP Y CUSTOMER SERVICE AREA SERVICE DRIVE O •� r7 w HC L N 0 0 o� L/� LO 8 DISPLAY O O O M b See LOS Oo d ' DISPLAY • - CUSTOMER CUSTOMER\ 0 . 0 0' 3 . ��' J — e 13' DRIVE AISLE SERVICE DRIVE T ILI 4_ 5 PC �1 I xHI ° a w CUSTOMER 1 R10 R0 CUSTOME JI J► NEW RETAINING WALL w SPLAY cus MER w 1 1 MAX HEIGHT 6' SERVIC d __I c DISPLAY cusroMER NEW VOLKSWAGEN SHOWROOM, DROP-OFF, AND SERVICE AREA. ° N w � DISPLAY COMBINED 15,514 SIF SERVICE CY) d �4 CUSTOMER 1SERVICE AREA z ISPLA 25 30 SERVICE DRIVE NEW MAZDA SHOWROOM, DROP-OFF, AND • I d 0 0 SPLA SERVICE AREA. SERVICE o COMBINED 10,877 SF _ DISPLAY �V 0 � O -?V.CE _ wR0 \ DISPLAY � O 1163 E w VICE a d - ISPLA F,C� R q y DISP T ° v 1SPL r> SHOWROOM AREA CUSTOMER CUSTOMER CUSTOMER CUSTOMER / a dn \4. C HC DISPLAY DISPLAY ° ° DISPLAY FFE:367.5 ER cusroMER us MER. DISPLAY 2 R d d � ` � ` `" � � ` � 0 � � � O O � 5 + DISPLAY DISPLAY a s SPA /`Y- 8R 3' d .0 0' DISPCA 20.00' 5.00' QI _ _ -- ...� .... �. \ `" �i -_��.. DISPLAY i LARGE TREES ,qL-6NG _ DI LAY DISPL-Y DOMINION TR 6SMISSION LINE EAS6'MENT. �, � { LO 0 SEE EASEMENT 6 AN. h' = x v DIS - DISPLAY DISPLAY O� J ° �O �..J DISPLAY 3 ; w°L.�' j` y �� - 5 - _ - o� 0 LL O I R 5 8 0 0 0 = _ EOM. -_ dd 6? ° e � ' • DISPLAY -ss ° d O 3' - CUSTOMER CUST MER O CUSTOMER�ISTDR rC. STOME CUSTOMER CUSTOMER CUSTOMER STOMER CU STOMER_. _CUSTOMER CUSTOMER CUSTO R CUSTOM - — w - PLAY DISPLAY ORNAMENTAL TREES INTERSPERSED _ - N0 � ES LON SANI A Y LI CO _ cn IN PARKING AREA. TREES TO HAVE - SEE LA SPLAY DISPLAY DIS AY _ IS � 00 w + x PERVIOUS PAVER OR GRATE FOR INFILTRATION. PERMANENT TRUNK PROTECTION AT 3' 00' _X — CUSTOMER MIN HEIGHT & 1'+ WIDTH TO BE PROVIDED. — O DISPLAY DOPLAY a >< DETAIL SPECIFICATION WILL BE PROVIDED. - - - PROPOSED LANDSCAPE SCHEDULE SPlant Planting Type Scientific Name CaI.�Height Quantity �i) Scarlet Oak Quercus Coccinea 3.5" Cal. 7 Honeylocust Gleditsia triacanthos 3.5" Cal. 9 Izy Shcdemoster' 0 European Hornbeam Carpinus betulus fastigiate' 2 5" Cal. 6 YQY Allegheny Serviceberry Amelonchier loevis & cvs 6' Ht. 52 Cumulus' shrub TO BE SPECIFIED 24" Ht. 290 000 Staghorn Sumac Rhus typhinia 24" HL 33 NOTE: NO SPECIES WILL EXCEED 25% OF PLANT TYPE. ADDITIONAL SMALL ORNAMENTAL TREES AND SHRUBS WILL BE SPECIFIED IN FUTURE SUBMISSIONS, DIVERSIFYING THE PALETTE, 6 � ° a d d ° d LANDSCAPING REQUIRED: SITE REQUIREMENT (32.7.9.8): 10% CANOPYREQUIRED. SITEAREA 113,824 SFx 10%(OR .10) = 11,382 SF CANOPY REQUIRED : 11,382 SF CANOPYPROVIDED: WILL BE PROVIDED WITH FINAL SITE PLAN PARKING LANDSCAPE (32. 7. 9. 6): 10 % OF PARKING PAVED AREA. 58,705 SF X .10 = 5,870.5 SF REQUIRED: 5,870.5 SF OF LANDSCAPED AREA PROVIDED: WILL BE PROVIDED WITH FINAL SITE PLAN ENTRY CORRIDOR. -LARGE SHADE STREE (3.5" CAL.) - 35' O. C. WITH INTERSPERSED ORNAMENTALS (6' HT.). 966 LF OF STREETSCAPE / 35 = 28 REQUIRED: 28 LARGE SHADE TREES W/ VARIABLE ORNAMENTALS PROVIDED: DUE TO EXISTING TRANSMISSION POWER LINE, SANITARY, WATER, AND UNDERGROUND TELEPHONE EASEMENTS PROVIDED ENTRY CORRIDOR PLANTING IS PREDOMINANTL Y SMALL ORNAMENTAL TREES AND EVERGREEN SHRUBS. w R 5 —- CUSTOMER d N DISPLAY DISPLAY 0' 10.00' DISPLAY w o DISPLAY ir DISPLAY DISP AY o� Cfl DIS LAY \ USTOMER ° DIS AY I ISPLA D SPLA 0 � DISPLAY DISP AY \ DISPLAY Q / N O'DISPL 00' DIS�LAY DIS (�. 1 PLAY DISPLAY � O AY o 4j� DISPLAY - O e ® DISPLAY O DISPLAY O 10,0 �' ISPLAY 0 DISPLAY DISPLA ` � 6) DIS LAY DISPLAY J w ZZ ° ° DISPL Y DISPLAY e / d AY DISPLAY a \ R DISPLAY UNDERGROUND TELEPHONE AND WATERLINE DISPLAY ALONG ROW. SEE VENT PLAN. w d d DISPLAY I LAY DISPL DISPLAY e DISPLAY ISPLAY W -C)3 LAY DISPLAY - d / l / �I DISPLAY V / /YOv DISPLAY LAY 7 Q0 DISPLAY DI PLO DISPLAY <O �S1��� DfsPL ' DISPLAY 9 CN IS LAY I PL DOLAY A DISPLAY O DISPLAY d SP Q S d DISPLAY DISPLAY OB DISPLAY d 269 �� �'8! d °d S ° d p� 67,5 b 90 y 33 �N d ° a d ° d w C3 d d ° d ° 0 0 20 40 .0 SHIM ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM N,LTH Op v JUST�HIMP a 45183 1_6 O SjONAL INITIAL SITE DEVELOPMENT PLAN ALBEMARLE COUNTY, VIRGINIA FLOW MAZDA / VW SUBMISSION: 2019.04.15 REVISION: FILE N0. LANDSCAPE PLAN SHEET C6 of C7 19.020 C6_ SET TRUNK PLUMB, SEE PLANS FOR EXACT LAYOUT AND SPACING ONE CENTRAL LEADER (NO CODOMINANT LEADERS, UNLESS SPECIFIED) ARBOR TIES, OR EQUIV. 2"X2" SQ. OAK STAKES SET 180 DEGREES APART OUTSIDE ROOT PACKAGE TOP OF ROOT BALL SHALL BE 2" ABOVE FINISHED GRADE 4" LAYER OF WOOD CHIPS. NO MORE THAN 1" OF MULCH ON TOP OF ROOT BALL. ROUND -TOPPED SOIL BERM 4" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE SHALL BE CONSTRUCTED AROUND THE ROOT BALL. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. REMOVE BURLAP, STRING, AND WIRE FROM TOP 2/3 OF ROOT BALL. BOTTOM OF ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL TO PREVENT SETTLING SLOPE AND ROUGHEN SIDES OF LOOSENED SOIL. PULL POTTING MIX AND ROOT MAT APART TO DIRECT THE OUTER ROOTS INTO THE ADJACENT SOIL. DO NOT LEAVE CIRCLING ROOTS NATIVE BACKFILL SOIL AMENDED WITH 15% DECOMPOSED ORGANIC COMPOST SOIL SURFACE ROUGHENED TO BIND NEW SOIL PREPARE SUBSOIL TO WITH MOUND TO PREVENT SETTLING 3X ROOTBALL DIAMETER DIM. i TREE PLANTING DETAIL Not To Scale 2X ROOTBALL DIAMETER DIM. ►I FINISHED GRADE EXISTING GRADE SET TOP OF ROOT CROWN 2" ABOVE FINISHED GRADE 3" DOUBLE -SHREDDED HARDWOOD MULCH. WATERING BERM SHAPE SOIL SURFACE TO PROVIDE 3' DIA. WATERING RING FINISHED GRADE TREE PIT DEPTH EQUALS ROOTBALL DEPTH. MEASURE BEFORE DIGGING 1. SEE PLANS FOR EXACT LAYOUT. SPACE PLANTS AS SPECIFIED IN PLANT LIST OR AS SHOWN. IF SPACING NEEDS ADJUSTING CONTACT LANDSCAPE ARCHITECT. 2. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. SHRUB PLANTING - SECTION Not To Scale Pavers top flush with asphalt Decorative Stone 10, 00' Parking Space - Width Gravel Runnel Sand 6" Gravel -;� :moo 0 Decorative Stone Gutter 10'X18' parking spaces Valkswagon Atlas Dimensions Tire Path 4'x4' Protective Tree Grate ATLASConcrete Tooter 0 4, 00' 5.00' 2% �e ATLASSmall, Medium or Large Tree species based on location 4" Wide Gravel Runnel Paver Concrete Footer -` - o 0 =o PASSAT PASSAT o� �o 90 1 00 00 0 o ATLAS ATLAS 0 0 0 0 4'x4' Protection Grate Concrete Footer 2"SM-9.5A Superpave 6" VDOT #21 A Basestone Compacted Subgrade min CBR=10 To be field verified Paver Concrete Tooter 2"SM-9.5A Superpave 6" VDOT #21 A Basestone Compacted Subgrade min CBR-10 To be field verified SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT !:!jA 912 E. HIGH ST. 434,227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM ALTH op J� v JUST�I a 4583 0 116 �, INITIAL SITE DEVELOPMENT PLAN ALBEMARLE COUNTY, VIRGINIA FLOW MAZDA / VW] SUBMISSION: 2019.04.15 REVISION: FILE NO. SITE DETAILS 19.020 SHEET C7 of C7 C7 Scientific Name: Amelanchier spp. (A. arborea, A. canadensis, A. laevis, and A. x grandiflora) Common Name: Serviceberry Species and Hybrids, Tree Forms Environmental Conditions: Hardiness Zone: 4 (3b) Soil Moisture: VERY WET VERY DRY occasionally consistently occasional prolonged saturated or moist, well periods of periods of very we soil drained soil dry soil d soil 1 1 2 3 4 1 5 1 6 7 1 8 1 9 10 1 11 112 Sun/Shade: prefers full sun, tolerates partial shade Salt: sensitive pH: < 7.5 Other: poor heat tolerance Insect/Disease Factors: none limiting, foliage diseases can be a problem but are very rarely fatal, fireblight, mites, scales can be serious problems if site requirements not met, `Autumn Brilliance' and `Princess Diana' resistant to leaf spot, `Autumn Brilliance' reportedly somewhat fireblight tolerant Growth Characteristics: Height: 20'-30' Width: 15'-25' Form/Habit: oval, multi -stem or single -stem forms available, must specify tree form as Amelanchier is also grown as a large shrub Rate: medium Ornamental Characteristics: Flower: white erect or pendulous clusters (depending on species or hybrid), in spring as leaves emerge or after (depending on species or hybrid), almost always showy Fruit: edible reddish -purple to black berries Seasonal Foliage Color: varies with cultivar, gray -green to dark green in summer, yellow to red in fall, reliably good fall color regardless of culitvar Bark: attractive, smooth gray streaked with darker longitudinal fissures, becoming ridged, furrowed and scaly with extreme age Transplant Issues: easy to transplant B&B or < 2" caliper bare root Management Issues: rootstock suckering possible on some cultivars, typically Sorbus is used for rootstock, although Tradition® has Crateagus rootstock which could produce thorny suckers Suggested Uses: narrow or wide street tree lawns/pits, parks Cultivars (Tree forms only): see chart on following page `Cumulus' Amelanchier spp. (Serviceberry Species and Hybrids) Tree Form Cultivars : Cultivar Growth Ornamental Other Characteristics Characteristics if differs from previous page `Autumn heavy flowering, lustrous dark green excellent heat and drought Brilliance' summer foliage, bright orange to red in fall tolerance for species `Cole's Select' 15' wide thicker and glossier small green foliage, orange -red to red in fall `Cumulus' 12%18' wide, yellow to orange -scarlet fall color may sucker at root collar faster growing Forest Prince heavy flowering, leathery dark green foliage, orange -red fall color Lustre® upright, open form flower clusters droop, `Rogers' leaves emerge purplish -bronze in color, orange -red fall color `Princess Diana' green foliage, bright red in fall, reportedly may be difficult to find in tree early and long lasting fall color form `Robin Hill' 12'-15' wide pink buds, early bloomer, bronze -tinged green foliage, yellow to red in fall `Snowcloud' 15' wide, foliage reportedly emerges with red tint, open habit blue-green to dark green in summer, copper -orange to scarlet in fall Spring Flurry® 35' tall, upright oval, green foliage in summer, orange fall color `JFS-Arb' strong central leader Spring Glory® 10'-15' tall, gray -green foliage, amber -orange fall color `Spirzam' 8-10' wide Tradition® strong central leader, heavy fruiting, gray -green foliage, orange `Trazam' good branching habit and red fall color 19 Scientific Name: Gleditsia triacanthos var. inermis Common Name: Thornless Common Honeylocust Environmental Conditions: Hardiness Zone: 4b (selected cultivars into 4a and 3b) Soil Moisture: VERY WET VERY DRY occasionally consistently occasional prolonged saturated or moist, well periods of periods of very wet soil drained soil dry soil d soil 1 V2 1 3 4 1 5 1 6 7 1 8 1 9 10 111 112 Sun/Shade: full sun Salt: some observed tolerance pH: < 8.2 Insect/Disease Factors: over -planting has encouraged severe insect problems in many areas, including spider mite borers, leaf spot, cankers, powdery mildew, wiches' broom, Honeylocust plant bug (`Moraine' and Skyline® have shown some resistance, green -leaved strains more tolerant such as Shademaster®, yellow -leaved strains very susceptible such as Sunburst@), mimosa webworm (`Moraine' resistant, `Green Glory' moderately resistant, Imperial® very susceptible), Thyronectria canker (HalkaTM resistant, Imperial®, Shademaster®, Skyline®, and Trueshade® partially resistant, `Morraine', Skyline® and Sunburst® susceptible), and Nectria canker (Sunburst® susceptible) Growth Characteristics: Height: 40'-80' Width: 30'-70' Form/Habit: oval to rounded, open, spreading Rate: fast Ornamental Characteristics: Flower: inconspicuous, not ornamentally important Fruit: long brown pods, most cultivars have little to no fruit Seasonal Foliage Color: light green in summer (dark green cultivars available), yellow in fall Bark: attractive, dark gray -brown, develops scaly platy ridges and deep furrows with age Other: drops leaves early Transplant Issues: easy to transplant B&B or < 2" caliper bare root Management Issues: small leaves easy for fall clean-up Suggested Uses: narrow or wide street tree lawns/pits, parks, suitable for CU-Structural Soi1TM Cultivars (all typically less than 50' high): HalkaTM (`Christie', zone 4a (3b), full branching, develops heavier caliper at an early age, essentially fruitless), `Moraine' (zone 3b, denser than species, upper branches ascending, lower branches more pendulous, dark green summer foliage, golden yellow fall color, fruitless form, reportedly susceptible to storm damage), Shademaster® (`PNI 2835', zone 3b, high vase shaped canopy, dark green summer foliage, late to turn yellow -green in fall, essentially fruitless), Skyline® (`Skycole', zone 3b, upright, broadly pyramidal, strong central leader, tight upright branching, dark green summer foliage, good yellow fall color), SpectrumTM , (`Speczem', rounded form, foliage has bright golden -yellow tips, essentially fruitless), True Shade® (fast growing, shiny dark bark, essentially fruitless) *Avoid `Rubylace' and Sunburst® (`Suncole') 3' 74 Scientific Name: Gleditsia triacanthos var. inermis `Impcole' Common Name: Imperial® Thornless Common Honeylocust Environmental Conditions: Hardiness Zone: 4a (3b) Soil Moisture: VERY WET VERY DRY occasionally consistently occasional prolonged saturated or moist, well periods of periods of very wet soil drained soil dry soil d soil 1 V2 1 3 4 1 5 1 6 7 1 8 1 9 10 111 112 Sun/Shade: full sun Salt: some observed tolerance pH: < 8.2 Insect/Disease Factors: over -planting of the species has encouraged severe insect problems in many areas, including spider mite borers, leaf spot, cankers, powdery mildew, wiches' broom, Honeylocust plant bug, mimosa webworm (Imperial® very susceptible), Thyronectria canker (Imperial®, partially resistant), and Nectria canker Growth Characteristics: Height: 30'-35' Width: 35' Form/Habit: broadly rounded, open and spreading, good horizontal branching angles Rate: fast Ornamental Characteristics: Flower: inconspicuous, not ornamentally important Fruit: essentially fruitless Seasonal Foliage Color: medium green in summer, yellow in fall Bark: attractive, dark gray -brown, develops scaly platy ridges and deep furrows with age Other: species generally drops leaves early Transplant Issues: easy to transplant B&B or < 2" caliper bare root Management Issues: small leaves easy for fall clean-up Suggested Uses: narrow or wide street tree lawns/pits, parks, suitable for CU-Structural Soi1TM Cultivars: above info is cultivar specific, other G. triacnathos cultivars are large trees 27 Scientific Name: Ulmus parvifolia Common Name: Chinese Elm or Lacebark Elm Environmental Conditions: Hardiness Zone: 5b Soil Moisture: VERY WET VERY DRY occasionally consistently occasional prolonged saturated or moist, well periods of periods of very wet soil drained soil dry soil d soil 1 1 2 1 3 4 1 5 1 6 7 1 8 1 9 10 111 112 Sun/Shade: full sun Salt: some observed tolerance pH: < 8.2 Insect/Disease Factors: species shows reliably good resistance to Dutch elm disease, elm yellows, and elm leaf beetle, as well as Japanese beetle Growth Characteristics: Height: 40'-75' Width: 30'-75' Form/Habit: variable, rounded or vase -shaped, often with pendulous branchlets, some almost American Elm -like with upright -spreading branches, while others are broader than tall with broad -spreading branches Rate: medium to fast Ornamental Characteristics: Flower: not ornamentally important, inconspicuous, late summer to early fall Fruit: 1/3" disc -like samara, ripens in fall Seasonal Foliage Color: lustrous dark green in summer, color varies in fall, yellow to reddish purple Bark: extremely ornamental, exfoliates and mottles in combinations of gray, green, orange, and brown, often with burnt orange corky lenticles Transplant Issues: transplant B&B Management Issues: none of significance Suggested Uses: narrow or wide street tree lawns/pits, parks, suitable for CU-Structural Soi1TM Cultivars: New cultivars selected for various ornamental characteristics and/or cold hardiness are becoming increasingly available. The following newer cultivars are hardy to Zone 5 and currently available: `Dynasty' (early introduction, so readily available cultivar, upright vase -shaped, 50' high, 45' wide, dull orange to red fall color but bark extremely inferior to following cultivars and often not even considered ornamental), Allee® (`Emerald Vase' or `Ewer II', upright -spreading form, 70' high, 60' wide, dense canopy, trunk irregularly fluted, excellent bark pattern — even on surface roots and 1"-2" diameter branches, bark has burnt orange corky lenticels, subdued yellow fall color), Athena® (`Emerald Isle' of `Emer I', broad -spreading habit, rounded/globe-shaped, 40' high, 55' wide, dense canopy, excellent bark pattern begins 2' off the ground, bark has burnt orange corky lenticels, leathery foliage, very dark green -almost black -in summer, bronze -brown in fall), Bosque® (`UPMTF', listed as zone 6, narrow crown, 30'wide, foliage is fine -textured and smaller than species, multi -color exfoliating bark), `Ohio' (moderately vase -shaped, probably 40'-50' high, 35'-45' wide, perhaps larger, appears more loose and open, attractive gray -orange exfoliating bark, smaller leaves, grass green summer foliage, grayish -red fall color, fruit ripens red -purple color), `Pathfinder' (vase -shaped, probably 35'-45' high, 30'-40' wide, perhaps larger, sometimes strong central leader, bark likely similar to `Ohio', yellow -green leaves in summer, grayish -red in fall, fruit ripens red -purple color), *Three cultivars selected for cold hardiness (possibly into zone 4) that may become more available in the near future: `Hallelujah' (fast growing, excellent foliage and bark detail), `Matthew' (upright vase -shape, strong branches, bark exfoliates at early age), and `Zettler' (strong, upright habit, excellent branching structure) 110 Scientific Name: Quercus coccinea Common Name: Scarlet Oak Environmental Conditions: Hardiness Zone: 5a Soil Moisture: VERY WET VERY DRY occasionally consistently occasional prolonged saturated or moist, well periods of periods of very we soil drained soil dry soil d soil 1 1 2 3 4 1 5 1 6 7 1 8 1 9 10 111 112 Sun/Shade: full sun Salt: unknown pH: < 7.5 Insect/Disease Factors: none serious or limiting Growth Characteristics: Height: 60'-70' (can reach 100'+ in wild) Width: 40'-50' Form/Habit: round, open Rate: slow Ornamental Characteristics: Flower: catkins, spring as leaves emerge Fruit: acorn Seasonal Foliage Color: glossy dark green in summer, russet -red to brilliant scarlet in fall, late to turn color in fall Bark: gray -brown Other: leaves persist throughout winter, particularly on young trees Transplant Issues: difficult to transplant B&B or bare root Management Issues: acorns may be a litter problem certain years Suggested Uses: wide street tree lawns/pits or parks preferred due to size Cultivars: none available Scientific Name: Carpinus betulus Common Name: European Hornbeam Environmental Conditions: Hardiness Zone: 5a (4) Soil Moisture: VERY WET VERY DRY occasionally consistently occasional prolonged saturated or moist, well periods of periods of very we soil drained soil dry soil d soil 1 1 2 3 4 1 5 1 6 7 1 8 1 9 10 1 11 112 Sun/Shade: full sun Salt: sensitive pH: < 8.2 Insect/Disease Factors: none serious or limiting, leaf minor possible, two -lined chestnut borer sometimes attacks `Fastigiata' Growth Characteristics: Height: 40'-60' Width: 30'-40' Form/Habit: pyramidal to rounded in youth, oval to rounded at maturity, fine textured branches, low branching tendency typically creates short trunk Rate: slow to medium Ornamental Characteristics: Flower: catkins with light -green bracts, spring Fruit: small green -brown nutlets at base of leafy flower bracts in pendulous clusters, mature in fall Seasonal Foliage Color: dark green in summer, yellow to yellow -green in fall, fall color is often late Bark: attractive, smooth slate -gray Transplant Issues: difficult to transplant B&B or bare root, somewhat slow to establish Management Issues: typically low branched, may require pruning to be used as street tree, tolerates heavy pruning, dieback can be a minor problem, narrow branch angles on columnar forms may be problem with heavy snow/ice loads Suggested Uses: wide street tree lawns/pits, narrow tree lawns/pits with pruning, parks, suitable for CU- Structural SoilTM, columnar forms useful for screening or hedging Cultivars: `Fastigiata' (35'-40' high, 20'-30' wide, narrowly conical becoming broadly oval -vase shaped with age, very dense branching), `Columnaris' (another upward branching and compact crown form commonly confused with `Fastigiata' in the nursery trade, theoretically `Columnaris' develops a central leader and `Fastigata' does not), `Pyramidalis' (just another name given to `Fastigiata' and `Columnaris' forms), `Franz Fontaine' (35'-40' high, 15' wide, narrowest form available, maintains narrow -columnar form with age as currant season's growth curves inward toward central leader) `Fastigiata' M Street Ecology: Street Trees Tree Belt & Green Belt Typologies Broad Green Belt This condition currently hosts trees planted along some of the busiest streets and widest sidewalk setbacks in Burlington. As deemed appropriate by the City Arborist, this condition may remain in selected areas in order to preserve large, healthy trees. However, this condition is prone to compaction and erosion in areas with adjacent on -street parking and/or high levels of pedestrian activity. This condition should be replaced with the standard tree belt as blocks are redeveloped when trees are in struggling condition or where preservation of the existing green belt is infeasible. Where these green belts are more than 8' wide, large, open soil volumes are often sufficient to support trees which survive to produce large canopies. Soil cells may be used beneath pavements if necessary to provide required soil volumes to new trees. Small, medium, and large tree species are suitable for planting in these conditions. Standard Green Belt This is the historic green belt condition in downtown. However, this condition is only desirable on primarily residential streets with low foot traffic and on blocks with slopes of less than 5%. Therefore, this condition may remain in selected areas as indicated in the Proposed Tree Belt Condition diagram. In order to protect against compaction and erosion that can damage roots and turf, an 18" "carriage walk" should be installed along the curb line within the green belt where possible. Soil cells may be utilized beneath pavements if needed to provide required soil volumes for new trees. Otherwise, horticultural soils should be used in unpaved portions of the green belt at a minimum depth of 36". Small, medium, and large tree species are suitable for planting in these conditions. Narrow Tree Belt This tree belt type exists where a narrow ROW accommodates only a slender green belt. In the future, this condition is only appropriate on primarily residential streets with low pedestrian traffic and where there is already a narrow/substandard green belt. In this condition, soil volumes in the green belt alone are insufficient to support trees which survive to produce large tree canopies. Soil cells or root trenches shall be used underneath pavement to provide required soil volumes for new trees. Only small tree species are appropriate for planting in these conditions. Public Sidewalk Horticultural Soil Iched Tree Well r Broad green belt condition with 8'+ of turf between the curb and sidewalk. Urban Lawn Mix Public Sidewalk a Soil Cell Well Horticultural Soil Standard green belt condition with an 78" "carriage walk" adjacent to the curb to protect tree roots and turf from erosion from adjacent on -street parking. Urban Lawn Mix Narrow green belt condition with soil cells to support small tree species. Downtown Street Design Standards DRAFT November 2017 City of Burlington 163 Street Ecology: Street Trees Tree Planting Details TREE PLANTING ATTREE WELL Trees planted within green belts shall follow all "Tree Installation Guidelines" on page 764, as well as these additional details. Groundcover • Plant Groundcover to cover the soils beyond the rootball. • Select Groundcover species from the recommended list in this document. Mulch • Option: Mulch at a 2" depth to cover entire soil surface within Downtown Street Design Standards DRAFT November 2017 City of Burlington 167 Street Ecology: Street Trees Tree Protection HORTICULTURAL SOIL Intent: To provide trees, turf, and groundcover plantings with a soil that allows them to thrive and to live out their longest possible healthy life in urban conditions. Location: Horticultural soils will fill the entire area of the tree well at a 3' minimum depth. These soils will also be used in soil cells and will provide the top 18" of the soil profile in turf Treebelts. Horticultural Soil is not intended for use in Bio-retention Plantings. Design: Consult a soils scientist or a licensed landscape architect, horticulturist, or arborist when designing Horticultural Soils to meet site and plant specific needs. Materials: Horticultural Soil is a fertile, friable, loamy topsoil mix suitable for the support of vegetative growth. Horticultural Soil Components: Topsoil, Organics, Coarse Sand, Fertilizer, and Biological Amendments • Topsoil: Unscreened Imported Topsoil or Existing Site Soil - Soil Texture: USDA loam, sandy clay loam, or sandy loam. - Soil Structure: Retain Peds of min 2" in size prior to mixing. - Organic Matter & Soil Chemistry: Suitable for growing the plants specified at the designed location - Soil Objects: < 5% of total topsoil volume: Clumps of Clay; Debris; Refuse; Roots; Stones; Sticks; Brush; or other litter. Remove all soil - objects >8" in their longest dimension. - Contaminants. The soil should have no herbicides, heavy metals, biological toxins, or hydrocarbons that will impact plant growth or are at levels exceeding the EPA's standards for soil contaminants. - Source: Unscreened Imported Topsoil must be harvested within 50 miles of Burlington, Vermont. Unscreened Imported Topsoil may not contain soils from sources defined by the United States Natural Resources Conservation Service as prime farmland, unique farmland, or farmland of statewide or local importance. • Organics: Compost shall be commercially prepared Pine Fines or an equivalent compost and must meet US Compost Council STA/TMECC criteria for "Compost as a Landscape Backfill Mix Component" and must not be derived from human waste or animal waste sources. • Coarse Sand: Clean, washed, natural sand, free of toxic materials, limestone, salt, shale, and slate particles. Must meet ASTM-03 Standards. • Fertilizer: If noted by soil test recommendations, add slow -release, organic fertilizer based on soil test and plant requirements. • Biological Amendments: Amendments such as Mycorrhizal additives, compost tea or other products intended to change the soil biology, as required based on Soil Foodweb Analysis by a qualified soil testing lab. Horticultural Soil Mix Requirements: Blend Topsoil, Organics, Coarse Sand, Fertilizer & Biological Amendments to make a new soil that meets the Project goals for the indicated planting area. • Clay content:15-25% by weight • Organic matter: 5-10% by weight • Coarse Sand: 30-65% by weight • Silt:15-25% by weight • Gravel content shall not exceed 10% by weight • Soluble Salt: < 2 dS/m • Cation Exchange Capacity: 7-15 • Water Permeability: 1-2 inches per hour when compacted to 85% of maximum dry density • pH: 6.0-6.5 • At the time of soil installation, add fertilizer or biological amendments, if required, to the planting soil mix at rates recommended by soil testing results for the plants to be grown. Depth: 3-4' (18" in turf -only areas of tree -belts where tree rooting volume is not required). SOILCELLS Intent: Soil Cells provide most the required soil volume for each tree downtown. These systems protect tree rooting soil from compaction while allowing pavement, vehicular access, and other streetscape uses above. Location: The primary location for these systems will be beneath permeable pavement in the Treebelt. These systems may also extend beneath the Concrete Sidewalk, Paved Bike Lanes, and in the Step -off zone. In residential areas, there the tree -belt is planted in turf Systems: Three systems are approved: • Silva Cells: manufactured by DeepRoot • StrataVault: manufactured by GreenBlue Urban • StrataCell: manufactured by GreenBlue Urban Loading: Soil Cells must be designed to accommodate H-20 loading for all pavements that they support. Soil Type: Install Horticultural Soils in Soil Cells. Horticultural Soil Mix Requirements may be modified to meet manufacturer's specifications. Downtown Street Design Standards DRAFT November 2017 City of Burlington 173 Tree Protection Street Ecology: Street Trees Installation: Per Manufacturer specification to accommodate paving and streetscape furnishings above as well as tree grate or curb/fence. CU-STRUCTURAL SOIL TM Intent: CU Structural Soil is a less -costly, but less -efficient method of providing rooting space for street trees beneath pavements as compared to Soil Cell systems. Materials: CU Structural Soil is a patented mixture of crushed stone, clay loam and Hydrogel developed by Cornell University. (Patent #5,849,069) Installation: Install per "CU-Structural Soil° A Comprehensive Guide" as published by Cornell University: http://www.hort. cornell.edu/uhi/outreach/pdfslCU-Structural %20Soi1 %20-%20 A%20Comprehensive%20Guide.pdf Efficiency: The Smiley -Bartlett Field Study suggests that a cubic foot of CU Structural Soil is capable of supporting 20% as much mature tree canopy volume as uncompacted Horticultural Soil. Use: In areas where soil cells cannot be used because of utilities or other underground impediments, CU Structural Soil may be used to provide no more than 10% of the required soil volume for each tree. CU Structural Soil may also be used to provide root paths beneath paved areas. Root paths provide access to nearby soils suitable for supporting tree growth that would otherwise be made inaccessible by compacted subsoils beneath paved areas. Source: CU-Structural Soil has been patented and licensed to qualified producers to ensure quality control; its trademarked names are CU-Structural Soil® or CU-Soil®. Obtain CU-Structural Soils an Amereq-licensed company. This assures that the material has been produced and tested to meet research -based specifications. DRAINAGE & ROOT AERATION Intent: To prevent subgrade moisture oversaturation and provide subsurface aeration in areas of tree planting. Material: Linear perforated subsoil drains which connect to the city's storm/combined sewer system. Operability: Valves that can cut off drainage to the city sewer systems must be installed at each connection to the sewer system. Valves will be installed in the "off" position. Alternatively, drains may be installed without valves, at a higher elevation in the soil profile as agreed upon with the Burlington Water Resources Department. This overflow system will drain automatically when saturation reaches a designed level. Pvc check -wells must be installed to monitor subgrade moisture at each street tree. Location: Underdrainage must be installed beneath all new street trees, regardless of the pre -construction infiltration rate of site soils. Drains must be installed in tree -belts beneath permeable pavements, tree wells, turf Treebelts, Soil Cells, and Sand Based Structural Soils. Performance: Underdrains must allow saturated soils to drain by gravity to a moisture level that can support the growth of street trees. SUBGRADE On sites where water infiltration is appropriate beneath planting soils: Prior to installing planting soil, loosen grade below the installed planting sol to a depth of 18 inches below the sub grade elevation in areas that are compacted and do not easily drain. Locate and avoid disturbing any existing utility lines or other subgrade structures. Percolation tests shall be performed to confirm minimum percolation rates of 1-2 inches per hour. On sites where water infiltration is inappropriate, provide impermeable liners and drainage pipes to drain all subsoil water into the sewer system while maintaining adequate moisture levels to support healthy plants. 174 City of Burlington DRAFT November 2017 Downtown Street Design Standards Street Ecology: Street Trees Tree Belt & Green Belt Typologies 8' Wide Brick Tree Belts Tree Belt with Planted Tree Wells This should be applied in commercial and mixed use areas with moderate pedestrian activity and where the preferred dimensions for the Pedestrian Zone for cross sections can be met. This may be installed adjacent to a Buffer Zone or a Protected Bike Facility at the sidewalk grade, such as the western blocks of Main Street. Trees in this condition are surrounded by salt -resilient plantings in a bed that infiltrates stormwater. Tree wells are typically 16' long, and are framed by 6" wide granite curbs on the sides parallel to the street with metal tree fencing on the perpendicular sides. Only large tree species are appropriate in this condition. See additional tree planting details in "Tree Planting at Tree Well" on page 185. Tree Belt with Tree Grate This should be applied in commercial and mixed use areas with moderate to high pedestrian activity, frequent restaurant/ retail destinations, and adjacent to loading zones. This may also be used for street types with a preferred Tree Belt/Furnishing Zone dimension of 8', but where the preferred or minimum dimensions for other Pedestrian Zone elements cannot be met due to encroachments or other constraints. This may be installed adjacent to a Buffer Zone or a Protected Bike Facility at the sidewalk grade, such as the block of Main Street adjacent to City Hall Park. Tree roots in this condition are protected by tree grates, and tree trunks by tree guards. Tree grates are typically 16' long, and flush with other pavements. Only large tree species are appropriate in this condition. See additional tree planting details in "Tree Planting at Tree Grate" on page 784. Permeable Pavers Soil Cell Planted Tree Well Horticultural Soil 8' wide tree belt utilizing permeable pavers and planted tree wells. Permeable Pavers 8' wide tree belt utilizing permeable pavers and tree grates and guards. Downtown Street Design Standards City of Burlington 179 Tree Planting Details Street Ecology: Street Trees TREE PLANTING ATTREE GRATE Trees planted within green belts shall follow all "Tree Installation Guidelines" on page 182, as well as these additional details. Soils • Soils are depressed 3" below the adjacent pavement grade, and 4-6" below the underside of the tree grate. Tree Anchor • Anchor to tree guard. Tree Guard • Install Tree Guards for all trees planted in tree grate condition. • Adjust guard in accordance with tree growth to avoid metal coming in contact with bark. Remove at the discretion of the City Arborist, when caliper is of sufficient size. Tree Grate • Tree Grate width must match Tree Belt/Furnishing Zone width. • Tree grate minimum length is twice the tree grate width. (6' X 12', 8' X 16', etc.) • Tree grate openings must be expanded over time to accommodate the tree's trunk without scarring it. • Tree grate shall be level with sidewalk per ADA requirements. Groundcover • Option: plant Sedum Blend listed in this document to cover soil surface under grate. Mulch • Mulch at a 2" depth to cover entire soil surface under grate. • Bare soil should be left at the base of the tree to avoid trunk suffocation or rot. • Weed prevention fabrics and geotextiles are not permitted. 184 City of Burlington Downtown Street Design Standards Street Ecology: Street Trees Tree & Plant Species MEDIUMTREES Gleditsia triacanthos v. inermis Gleditsia triacanthos v inermis Gleditsia triacanthos v. inermis Halka Honeylocust Imperial Honeylocust Skyline Honeylocust Height: 30-40' Height: 25-30' Height: 35-45' Spread: 30-40' Spread: 30-35' Spread: 30-35' Required Soil Volume: 1000 ft3 Required Soil Volume: 1000 ft3 Required Soil Volume: 1000 ft3 Planting Condition: Brick Treebelt, Broad Planting Condition: Brick Treebelt, Broad Planting Condition: Brick Treebelt, Broad Treebelt, Turf Treebelt, Narrow Treebelt, Lawn Treebelt, Turf Treebelt, Narrow Treebelt, Lawn Treebelt, Turf Treebelt, Narrow Treebelt, Lawn Salt Tolerance: Good Salt Tolerance: Good Salt Tolerance: Good VT Native: Yes VT Native: Yes VT Native: Yes Notes: Halka is a nearly fruitless, thornless Notes: Imperial is a nearly fruitless, thornless Honeylocust cultivar. Honeylocust cultivar. It is one of the most Notes: Skyline has a somewhat pyramidal compact Honeylocusts. form. It is a thornless and nearly fruitless Honeylocust cultivar. Downtown Street Design Standards DRAFT November 2017 City of Burlington 187 Street Ecology: Street Trees Tree & Plant Species SMALLTREES Acer truncatum 'Main Street' Shantung Maple Height: 20-25' Spread:20-30' Required Soil Volume: 600 ft3 Amelanchier arborea Downy Serviceberry Height:15-25' Spread: 15-25' Required Soil Volume: 600 ft3 Planting Condition: Brick Treebelt, Broad Planting Condition: Broad Treebelt, Turf Treebelt, Turf Treebelt, Narrow Treebelt, Lawn Treebelt, Lawn Salt Tolerance: Moderate VT Native: No Salt Tolerance: Moderate VT Native: Yes Amelanchier laevis sp. Allegheny Servicebery Height:15-25' Spread: 15-25' Required Soil Volume: 600 ft3 Planting Condition: Broad Treebelt, Turf Treebelt, Lawn Salt Tolerance: Moderate VT Native: Yes Notes: Good under power lines. Compact, Notes: 'Spring Flurry' cultivar is Notes: 'Snowcloud' and'Majestic' somewhat low -branched street tree. recommended for its fastigiate form. Good cultivars are recommended for their form under power lines in residential areas. Avoid and vigor. Good under power lines in areas of high soil compaction. residential areas. Avoid areas of high soil compaction. Downtown Street Design Standards DRAFT November 2017 City of Burlington 189 Roadway Zone Street Ecology: Stormwater PERVIOUS PAVERS IN PARKING ZONE (PILOT) Parking zones are excellent applications for interlocking concrete pervious paver systems. Many interlocking concrete unit pavers are designed specifically for stormwater management applications. They allow water to pass through joint gaps that are filled with small aggregates and infiltrate into a thick gravel subgrade. This system is widely applicable to both small and large paving applications and it offers the flexibility to be repaired because small sections can be removed and replaced. Interlocking concrete unit pavers offer flexibility in color, style, joint configuration, and paving pattern. It is important to note that selected pervious joint pavers along pedestrian areas must be ADA-compliant and not cause tripping hazards. When installing pervious joint pavers, care should be taken to assure that the base and subgrade is properly constructed to minimize the potential for differential settlement. Regular vacuum cleaning of the paverjoints will help prevent clogging and extend the longevity of the system. Pervious paving within the parking zones of streets can be combined with other curb zone landscape stormwater treatments such as stormwater curb extensions and green gutters to maximize the potential for stormwater management. Key Design Considerations This treatment should be piloted in alleys or on low volume streets before applying this treatment broadly throughout downtown. This treatment may only be applied in consultation with the Department of Public Works until such time it is no longer indicated as a pilot in these standards. Vehicle Loading Requirements Pervious paving systems need to maintain H2O vehicle loading capability. Maximum Gap Between Pavers A''/2" maximum gap is to be maintained between pavers to be ADA compliant. A 1/4" gap is preferred where pedestrians will traverse. Minimum Gravel Sub -base Depth A 12" minimum gravel sub -base is necessary under parking zone pervious paving systems. Banding required as is show in the photos? Interlocking concrete pavers Sand setting bed Compacted subgrade Base course A residential street with interlocking concrete pavers within the parking zone. A urban street with interlocking concrete pavers within the parking zone and tree belt zone. 2o6 City of Burlington DRAFT November 2017 Downtown Street Design Standards Street Ecology: Stormwater Pedestrian Zone Pedestrian Zone PERVIOUS PAVERS IN TREEBELT ZONE Sidewalk tree belt zones on urban streets are excellent applications for interlocking concrete pervious paver systems. Many interlocking concrete unit pavers are designed specifically for stormwater management applications. They allow water to pass through joint gaps that are filled with small aggregates and infiltrate into a thick gravel subgrade. This system is widely applicable to both small and large paving applications and it offers the flexibility to be repaired because small sections can be removed and replaced. Interlocking concrete unit pavers offer flexibility in color, style, joint configuration, and paving pattern. Along streets that utilize salt in winter conditions, only clay pavers should be used. It is important to note that selected pervious joint pavers along pedestrian areas must be ADA-compliant and not cause tripping hazards. When installing interlocking concrete pavers, care should be taken to assure that the base and subgrade is properly constructed to minimize the potential for differential settlement. It is important to design the pervious paver system sub -base to allow for the infiltration of stormwater, but also be able to consistently support the weight of occasional emergency and/or heavy duty utility vehicles traversing its surface and not allow pavers to buckle over time. Regular vacuum cleaning of the paver joints will help prevent clogging and extend the longevity of the system. In addition, periodic replenishment of the joints with fill sand/stones will help maintain structural stability over time. Pervious paving within the tree belt zones of streets can be combined with other sidewalk landscape stormwater treatments such as stormwater planters and tree grate stormwater planters to maximize the potential for stormwater management. Key Design Considerations Vehicle Loading Requirements Pervious paving systems need to maintain H2O vehicle loading capability. Maximum Gap Between Pavers A 1/4" gap is preferred where pedestrians will traverse. A''/z" maximum gap is to be maintained between pavers to be ADA compliant. Minimum Gravel Sub -base Depth A 12" minimum gravel sub -base is necessary under parking zone pervious paving systems. Compact base material to allow for enough structural support, but to also allow for infiltration. Pervious brick pavers in the tree belt zone on S. Winooski Ave. This example accepts sheet flow from non -pervious sidewalks. A urban street with a centralized tree belt zone with granite pavers separated by %" wide joints to capture stormwoter runoff. Downtown Street Design Standards DRAFT November 2017 City of Burlington 207