HomeMy WebLinkAboutARB201900071 Checklist 2019-06-25ARB2019-71: The Chiropractic Office, hanging panel sign
SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business
Updated: 6-17-2016
6/25/2019
REF
CHECKLIST ITEM
NOTES
TYPE
9.b
For internally illuminated signs, channel lettering (mounted on a raceway
N/A: hanging panel sign proposed; no
or individual letters) is preferred to cabinet signs.
illumination proposed
5.b
When channel letters cannot be adequately accommodated, internally
illuminated cabinet signs may be considered.
6
Reader boards are discouraged.
MATERIALS
4.c
Materials used in the sign should complement the building being served
OK: MDO (plywood) and vinyl applique is
by the sign.
common and appropriate for a panel sign
COLOR
4.e
Color for raceway -mounted channel letters, the raceway shall match the
N/A: ceiling mount by 2x2's
wall color.
Sign colors must be harmonious with each other.
The CSP for this TMP requires an ivory
background, but white appears to be proposed
Sign colors must not clash with the site, when viewed in daylight and at
OK
night.
Overly intense color, (such as dayglo or fluorescent colors), are
OK: no intense colors proposed
prohibited.
Use of three colors or less (black and white considered as colors).
OK: two colors proposed: forest green
Additional colors may be approved if they contribute to the sign
(Pantone 3302C) and teal (Pantone 321C).
balance/unity.
While the logo may be the combination of the
two, as proposed, all of the text must be forest
green, and so the teal tagline must be revised.
The CSP also states that a forest green border
is required, which this sign proposal lacks. The
sign drawing must be revised to include a
border.
ARB2019-71: The Chiropractic Office, hanging panel sign
6/25/2019
REF
I CHECKLIST ITEM
NOTES
SIZE, SCALE, PROPORTION, AND LOCATION
4.b
Signs may not exceed the size, height and setback requirements as
The sign height is 24" H by 105.5" L. The
outlined in Section 4.15 of the Albemarle County Zoning Ordinance
height complies with the maximum outlined in
(unless sign has a variance).
the CSP (24"), but the length (at 8.7916') is
longer than the maximum length (8') permitted
in the CSP and must be revised
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall area is a good
N/A
A.A
working proportioning system for placing a sign.
Appendix
Color, form, surface pattern, shape, and disposition of elements and
OK
A.A.4
openings in an architectural design can affect our perception of scale and
can impact the appearance of a sign on a building.
9.d
The wall sign's size must coordinate with the architectural element's
OK: the sign location (centered in the bay,
size.
hanging from the eave) complies with the
criterion in the CSP.
The sign should not over -crowd the architectural element, the wall, or the
sign area.
Buildings and building elements should not be used as billboards.
N/A
9.a
Wall signs must integrate with the building's architecture.
OK: the proposed sign location is centered in
the bay, hanging from the eave, as per the
The sign placement should not obscure architectural features or details,
(such as cornices, windows, columns, pilasters and paneling).
CSP.
9.d
An appropriate height for channel letters in a 30" high sign band is 18".
N/A
This allows 6" of unoccupied space above and below the letters.
4" of clear space above, below, and to the sides of a channel letter sign is
considered a minimum, with larger clearances required for larger sign
bands.
Degree of visibility, the distance from the Entrance Corridor, and the
OK
architectural design of the building/area will determine sign size,
placement, and proportions.
4.d
Lettering should be in proportion (font size and typeface style) to the sign
OK
and the building.
Use of three typefaces or less.
OK: two typefaces proposed
ARB2019-71: The Chiropractic Office, hanging panel sign
6/25/2019
REF
CHECKLIST ITEM
NOTES
Additional typefaces may be approved if they contribute to a
balanced/legible/unified sign design.
N/A
9.e.iv
The width of the outline must be in proportion to the width of the letter.
N/A: no outline proposed
An outline width of 1/8" has been found to be an appropriate sign
dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
4.f
The ARB may require that the color and scale of standard templates for
trademarks, service marks, corporate logos and graphics be modified.
OK
When used, trademarks, service marks, corporate logos and/or graphics
should be incorporated as an integral part of the overall sign.
OK: the logo is appropriately scaled and
placed to the left of the text
5.a
External (or no) illumination is preferred for approved graphics/logos;
NA: no external illumination proposed
5.b
internal illumination may be considered for approval on a case -by -case
basis.
NA: no internal illumination proposed
LIGHTING
9.e.i
External (or no) illumination is preferred for wall signs.
NA: no external illumination proposed
5.f
Any internal illumination is considered to contribute to visual clutter and
will be limited.
NA: no internal illumination proposed
5.c
Internal illumination design approval will be evaluated on size, balance,
complexity, and distance from the Entrance Corridor.
9.e.iv
The backgrounds of such cabinet signs must be made opaque (zero light
transmission).
N/A: no cabinet signs proposed
5.e
External illumination should be shielded and not create glare.
NA: no external illumination proposed
All external light sources shall be white.
9.ii
Sign lighting (external) should be shielded so that it illuminates only face
of the sign and does not shine beyond the edge of the sign.
9.iii
Channel letters with translucent faces must have no light spilling outward
from the top, bottom, sides or back.
N/A: no internally -lit channel letters proposed
Faces and returns of channel letters shall be opaque when back -lit (halo-
lit).
N/A: no halo -lit channel letters proposed
ARB2019-71: The Chiropractic Office, hanging panel sign
6/25/2019
REF
CHECKLIST ITEM
NOTES
9.iv
Cabinet signs shall have a non -illuminated background, or an opaque
N/A: no cabinet signs proposed
(zero light transmission) background.
Cabinet signs shall be constructed such that no light spills outward from
the top, bottom, sides or back.
5.g
All illumination shall be non -blinking.
N/A: no illumination proposed
5.h
An exposed light source that forms the body of a sign, (such as exposed
N/A: none such proposed
neon signs), shall not be used in the Entrance Corridors.
ARB ACTIONS
If LED lighting is proposed the sign drawing must state The level of
N/A: no illumination proposed
illumination provided by the LED lights will not exceed the illumination
produced by a single stroke of 30 milliamp (ma) neon.
Action on ARB-P (BP)2001-12
Red acrylic #2283 has been determined to be an
N/A: no red color proposed
Wood Grill
inappropriate color for signs. Pantone color match
for 2283 is 485C. Red #2793 has been approved as
an acceptable substitute. Pantone color match for
2793 is 187C. (See below.)
12/21/15 action on ARB 2015-
Generally, for signs in the Entrance Corridors, red 485
114 & -115 Shell Signs
may be acceptable on a case -by -case basis as a
secondary color.
ARB Action Memo: 5/7/12
Visual clutter resulting from adjacency, for example
OK
at the Hardee's locations, is a reasonable basis for
not allowing illumination of the graphic.
ARB Action
Accent color letters can be used in a sign when portrayed as a
OK: the proposed teal is an accent color on the
Memo: 8/3/2015
graphic, up to 33% of the length of the sign.
logo, and comprises less than 33% the total
sign area
ARB2019-71: The Chiropractic Office, wall sign
HNM 6/25/19
COMPREHENSIVE SIGN CRITERIA — STONE RIDGE SHOPPING CENTER (VILLAGE GREEN)
ARB-2013-98, ARB-2014-137
Tax Map 61W, Section 3, Parcel 21A
SIGN FEATURE
Approved Criteria
SIGN TYPE
Wall panel or hanging panel OK: hanging panel sign proposed
Channel letter
LETTER FACE
Panel: Forest Green OK: forest green (PMS 3302C) proposed as primary colo
COLOR
Channel Letter: White )ut seconds color Teal PMS 321 Q also proposed
TRIM CAP COLOR/
Panel: N/A N/A (panel sign)
RETURN COLOR
Channel letter: Bronze
RACEWAY COLOR
Panel: N/A N/A (panel sign)
Channel letter: To match color of wall to which it is attached
PANEL/CABINET
Ivory �,a,;kground color not provided, but appears white instead of ivory
FACE COLORS
SIZE LIMITATIONS
Hanging panel: Front & Rear: 21" — 24" (t) x 8' (w)
Wall panel: Front: 21' - 24" (t) x 8' (w) 2' H x 8.7916' W --> latter must be redu
Rear: as per general sign guidelines without overlapping brick detailing
LOCATION(S)
Wall Panel: Centered on the wall above the business entrance in both the front and rear
elevations - not permitted on the wall under the colonnade.
Hanging Panel: Centered between the colonnade columns in both the front and rear
elevations. OK: centered in bay
Channel letter: In the approved sign bands as shown on thephoto-rendering below
LOGO/GRAPHICS
Panel: Forest green border No border provided
DETAILS
Channel letter: No limit to graphic colors as long as total number per sign is limited to
three and they contribute to a coordinated appearance.
ILLUMINATION
Panel: No internal illumination; existing wall fixtures may be reused OK: no illumination
DETAILS
Channel letter: may be internally illuminated proposed
TEXT
No limits other than standard guidelines
LETTER
No limits other than standard guidelines
TYPE/FONT
MATERIALS
No limits other than standard guidelines OK: MDO (Plywood) proposed
This form outlines the specific design criteria established for signs at this location. All standard ARB Sign Guidelines also apply.
Type
Double -sided monument, multi -tenant
Materials
Aluminum, vinyl, stone & paint
Location
1937 Commonwealth Drive, south end of the parcel, just west of the existing site entrance from
Hydraulic Road, as shown on the approved drawing
Overall sign size
5' 2.75" w x 9' 3" t
Tenant panel height
7" (t)
Note: All seven panels equal in size
Text
Sign monument
stone ridge
commons
Tenant panel
Permits to be applied for separately
Graphic
Sign monument
None
Tenant panel
Permits to be applied for separately
Colors
Sign monument
Cabinet: Tan: PMS 7502
Cornice: Tan: PMS 7502 (20%)
Base: Stone Craft: Hamilton Farmledge
Text "stone ridge commons": Dark Gray: PMS 418
Tenant panels
Background: White
Text: Dark Gray Ave Vinyl)
Illumination
None
Landscaping
As pera roved planting plant including Juniper conferta, Nassella tenuissima & Lirio e muscari
ed
TILLAGE GREEN SfGN BAND
A 14'-6"
�AUA"
GLEBwrk X RPi
YE91CYhf+' X €-SEAILar
MIE X OfJ 03V 24i9
Ak 18AFT
LR
COPYRIGHT20f3TALLEY ANCHOR S;GNCO
RO1LSIhFS GI IAN_C��
mm+dC/AM'4f111Y Ih7 Wh '01 ' %IIOPRy B'QII C4 �P 0MFQ7 }
.oiwY �or.iln� I�.�b �d.�1r.
i.. .. :Iin�.mrRl i.rdbr.l.p hru
ap.�i a.w�. and m.rr:,
lIiF�44 :� ��i �'+r�rYa7Pi4i'
•. Im fir. a.or,..bx�. ... .���r..lr r.r�..,
S0N iw AY6F U1GAIM$d7HESF WAL4
A FLA& - uMEGPW WNIN0 GM%LJ%ACj
REGULAMONS ANDEMMASCE COFF"P!
SON pESk-N rUIOE.UNE.S FOR SUF,
G�aIC.N+�h�tlaDr4kTIPl1
S IGNSK4Y SE LU;ATM W THE59 VK4
APrAmaURJF1'Yr0WPIIH0a6VV X
PEGUL MSAFDENirANcEOARR3R
SI(rH El[JPN GUDEUI$3 FORSM
DIMH AWMWdRTI .
ILlJrF�i4rAIf510tI WhP9 AWL THI: Mr
siEEAw3KAPE As7mE CENFEIG
SIGNBMD)
1; —4 91QI, C'0UF4NY
Th rx "a=lf.. *?W-IMW
Completeness Check for Signs
Project #/Name: _ARB2019-71: The Chiropractic Office wall sign
Date Received at County: _6/21/19
Date Received in Design Planning: _6/24/19
Date of Checklist Check: _6/25/19 Assigned to/Date: _HNM 6/25/19
FEES M
3. ARB Review — Will the permanent sign(s) be constructed in an Entrance Corridor?
(See the Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors)
❑ Yes ('Phis sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $129.00
Comprehensive Sign Review. See ARB requirements next pages)
® Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee
Comprehensive Sign Review. See ARB requirements next pages)
❑ No ('This sign will not be constructed in an Entrance Corridor) $ 0.00
FEE TOTAL (Please add all the amounts checked in sections I — 3): $
WALL SIGNS
® A drawing, to scale, showing dimensions of the sign (length, height, depth).
® Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing
® The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also
include these dimensions on the diagrams provided in Appendix B)
® Sign lettering and/or graphics in their proposed location.
® Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color
illustration of the front and side elevations of the sign showing:
o Indication of sign type (channel letters, cabinet, panel, etc.).
o Indicate on the drawings the proposed materials and colors. Include standard color identification numbers
(Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter
signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is
attached.
o Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint
chips that accurately reflect the proposed colors are acceptable.)
o Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style,
shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17.
o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque
materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be
detected nor can objects be seen through it.
ILLUMINATION REQUIREMENTS
❑ The location of proposed light fixtures identified on a plan and/or elevation
❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must
meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance.
NOTES: application is complete