HomeMy WebLinkAboutARB201900071 Checklist 2019-06-25ARB2019-71: The Chiropractic Office, hanging panel sign SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business Updated: 6-17-2016 6/25/2019 REF CHECKLIST ITEM NOTES TYPE 9.b For internally illuminated signs, channel lettering (mounted on a raceway N/A: hanging panel sign proposed; no or individual letters) is preferred to cabinet signs. illumination proposed 5.b When channel letters cannot be adequately accommodated, internally illuminated cabinet signs may be considered. 6 Reader boards are discouraged. MATERIALS 4.c Materials used in the sign should complement the building being served OK: MDO (plywood) and vinyl applique is by the sign. common and appropriate for a panel sign COLOR 4.e Color for raceway -mounted channel letters, the raceway shall match the N/A: ceiling mount by 2x2's wall color. Sign colors must be harmonious with each other. The CSP for this TMP requires an ivory background, but white appears to be proposed Sign colors must not clash with the site, when viewed in daylight and at OK night. Overly intense color, (such as dayglo or fluorescent colors), are OK: no intense colors proposed prohibited. Use of three colors or less (black and white considered as colors). OK: two colors proposed: forest green Additional colors may be approved if they contribute to the sign (Pantone 3302C) and teal (Pantone 321C). balance/unity. While the logo may be the combination of the two, as proposed, all of the text must be forest green, and so the teal tagline must be revised. The CSP also states that a forest green border is required, which this sign proposal lacks. The sign drawing must be revised to include a border. ARB2019-71: The Chiropractic Office, hanging panel sign 6/25/2019 REF I CHECKLIST ITEM NOTES SIZE, SCALE, PROPORTION, AND LOCATION 4.b Signs may not exceed the size, height and setback requirements as The sign height is 24" H by 105.5" L. The outlined in Section 4.15 of the Albemarle County Zoning Ordinance height complies with the maximum outlined in (unless sign has a variance). the CSP (24"), but the length (at 8.7916') is longer than the maximum length (8') permitted in the CSP and must be revised Appendix A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall area is a good N/A A.A working proportioning system for placing a sign. Appendix Color, form, surface pattern, shape, and disposition of elements and OK A.A.4 openings in an architectural design can affect our perception of scale and can impact the appearance of a sign on a building. 9.d The wall sign's size must coordinate with the architectural element's OK: the sign location (centered in the bay, size. hanging from the eave) complies with the criterion in the CSP. The sign should not over -crowd the architectural element, the wall, or the sign area. Buildings and building elements should not be used as billboards. N/A 9.a Wall signs must integrate with the building's architecture. OK: the proposed sign location is centered in the bay, hanging from the eave, as per the The sign placement should not obscure architectural features or details, (such as cornices, windows, columns, pilasters and paneling). CSP. 9.d An appropriate height for channel letters in a 30" high sign band is 18". N/A This allows 6" of unoccupied space above and below the letters. 4" of clear space above, below, and to the sides of a channel letter sign is considered a minimum, with larger clearances required for larger sign bands. Degree of visibility, the distance from the Entrance Corridor, and the OK architectural design of the building/area will determine sign size, placement, and proportions. 4.d Lettering should be in proportion (font size and typeface style) to the sign OK and the building. Use of three typefaces or less. OK: two typefaces proposed ARB2019-71: The Chiropractic Office, hanging panel sign 6/25/2019 REF CHECKLIST ITEM NOTES Additional typefaces may be approved if they contribute to a balanced/legible/unified sign design. N/A 9.e.iv The width of the outline must be in proportion to the width of the letter. N/A: no outline proposed An outline width of 1/8" has been found to be an appropriate sign dimension. TRADEMARKS, CORPORATE LOGOS AND GRAPHICS 4.f The ARB may require that the color and scale of standard templates for trademarks, service marks, corporate logos and graphics be modified. OK When used, trademarks, service marks, corporate logos and/or graphics should be incorporated as an integral part of the overall sign. OK: the logo is appropriately scaled and placed to the left of the text 5.a External (or no) illumination is preferred for approved graphics/logos; NA: no external illumination proposed 5.b internal illumination may be considered for approval on a case -by -case basis. NA: no internal illumination proposed LIGHTING 9.e.i External (or no) illumination is preferred for wall signs. NA: no external illumination proposed 5.f Any internal illumination is considered to contribute to visual clutter and will be limited. NA: no internal illumination proposed 5.c Internal illumination design approval will be evaluated on size, balance, complexity, and distance from the Entrance Corridor. 9.e.iv The backgrounds of such cabinet signs must be made opaque (zero light transmission). N/A: no cabinet signs proposed 5.e External illumination should be shielded and not create glare. NA: no external illumination proposed All external light sources shall be white. 9.ii Sign lighting (external) should be shielded so that it illuminates only face of the sign and does not shine beyond the edge of the sign. 9.iii Channel letters with translucent faces must have no light spilling outward from the top, bottom, sides or back. N/A: no internally -lit channel letters proposed Faces and returns of channel letters shall be opaque when back -lit (halo- lit). N/A: no halo -lit channel letters proposed ARB2019-71: The Chiropractic Office, hanging panel sign 6/25/2019 REF CHECKLIST ITEM NOTES 9.iv Cabinet signs shall have a non -illuminated background, or an opaque N/A: no cabinet signs proposed (zero light transmission) background. Cabinet signs shall be constructed such that no light spills outward from the top, bottom, sides or back. 5.g All illumination shall be non -blinking. N/A: no illumination proposed 5.h An exposed light source that forms the body of a sign, (such as exposed N/A: none such proposed neon signs), shall not be used in the Entrance Corridors. ARB ACTIONS If LED lighting is proposed the sign drawing must state The level of N/A: no illumination proposed illumination provided by the LED lights will not exceed the illumination produced by a single stroke of 30 milliamp (ma) neon. Action on ARB-P (BP)2001-12 Red acrylic #2283 has been determined to be an N/A: no red color proposed Wood Grill inappropriate color for signs. Pantone color match for 2283 is 485C. Red #2793 has been approved as an acceptable substitute. Pantone color match for 2793 is 187C. (See below.) 12/21/15 action on ARB 2015- Generally, for signs in the Entrance Corridors, red 485 114 & -115 Shell Signs may be acceptable on a case -by -case basis as a secondary color. ARB Action Memo: 5/7/12 Visual clutter resulting from adjacency, for example OK at the Hardee's locations, is a reasonable basis for not allowing illumination of the graphic. ARB Action Accent color letters can be used in a sign when portrayed as a OK: the proposed teal is an accent color on the Memo: 8/3/2015 graphic, up to 33% of the length of the sign. logo, and comprises less than 33% the total sign area ARB2019-71: The Chiropractic Office, wall sign HNM 6/25/19 COMPREHENSIVE SIGN CRITERIA — STONE RIDGE SHOPPING CENTER (VILLAGE GREEN) ARB-2013-98, ARB-2014-137 Tax Map 61W, Section 3, Parcel 21A SIGN FEATURE Approved Criteria SIGN TYPE Wall panel or hanging panel OK: hanging panel sign proposed Channel letter LETTER FACE Panel: Forest Green OK: forest green (PMS 3302C) proposed as primary colo COLOR Channel Letter: White )ut seconds color Teal PMS 321 Q also proposed TRIM CAP COLOR/ Panel: N/A N/A (panel sign) RETURN COLOR Channel letter: Bronze RACEWAY COLOR Panel: N/A N/A (panel sign) Channel letter: To match color of wall to which it is attached PANEL/CABINET Ivory �,a,;kground color not provided, but appears white instead of ivory FACE COLORS SIZE LIMITATIONS Hanging panel: Front & Rear: 21" — 24" (t) x 8' (w) Wall panel: Front: 21' - 24" (t) x 8' (w) 2' H x 8.7916' W --> latter must be redu Rear: as per general sign guidelines without overlapping brick detailing LOCATION(S) Wall Panel: Centered on the wall above the business entrance in both the front and rear elevations - not permitted on the wall under the colonnade. Hanging Panel: Centered between the colonnade columns in both the front and rear elevations. OK: centered in bay Channel letter: In the approved sign bands as shown on thephoto-rendering below LOGO/GRAPHICS Panel: Forest green border No border provided DETAILS Channel letter: No limit to graphic colors as long as total number per sign is limited to three and they contribute to a coordinated appearance. ILLUMINATION Panel: No internal illumination; existing wall fixtures may be reused OK: no illumination DETAILS Channel letter: may be internally illuminated proposed TEXT No limits other than standard guidelines LETTER No limits other than standard guidelines TYPE/FONT MATERIALS No limits other than standard guidelines OK: MDO (Plywood) proposed This form outlines the specific design criteria established for signs at this location. All standard ARB Sign Guidelines also apply. Type Double -sided monument, multi -tenant Materials Aluminum, vinyl, stone & paint Location 1937 Commonwealth Drive, south end of the parcel, just west of the existing site entrance from Hydraulic Road, as shown on the approved drawing Overall sign size 5' 2.75" w x 9' 3" t Tenant panel height 7" (t) Note: All seven panels equal in size Text Sign monument stone ridge commons Tenant panel Permits to be applied for separately Graphic Sign monument None Tenant panel Permits to be applied for separately Colors Sign monument Cabinet: Tan: PMS 7502 Cornice: Tan: PMS 7502 (20%) Base: Stone Craft: Hamilton Farmledge Text "stone ridge commons": Dark Gray: PMS 418 Tenant panels Background: White Text: Dark Gray Ave Vinyl) Illumination None Landscaping As pera roved planting plant including Juniper conferta, Nassella tenuissima & Lirio e muscari ed TILLAGE GREEN SfGN BAND A 14'-6" �AUA" GLEBwrk X RPi YE91CYhf+' X €-SEAILar MIE X OfJ 03V 24i9 Ak 18AFT LR COPYRIGHT20f3TALLEY ANCHOR S;GNCO RO1LSIhFS GI IAN_C�� mm+dC/AM'4f111Y Ih7 Wh '01 ' %IIOPRy B'QII C4 �P 0MFQ7 } .oiwY �or.iln� I�.�b �d.�1r. i.. .. :Iin�.mrRl i.rdbr.l.p hru ap.�i a.w�. and m.rr:, lIiF�44 :� ��i �'+r�rYa7Pi4i' •. Im fir. a.or,..bx�. ... .���r..lr r.r�.., S0N iw AY6F U1GAIM$d7HESF WAL4 A FLA& - uMEGPW WNIN0 GM%LJ%ACj REGULAMONS ANDEMMASCE COFF"P! SON pESk-N rUIOE.UNE.S FOR SUF, G�aIC.N+�h�tlaDr4kTIPl1 S IGNSK4Y SE LU;ATM W THE59 VK4 APrAmaURJF1'Yr0WPIIH0a6VV X PEGUL MSAFDENirANcEOARR3R SI(rH El[JPN GUDEUI$3 FORSM DIMH AWMWdRTI . ILlJrF�i4rAIf510tI WhP9 AWL THI: Mr siEEAw3KAPE As7mE CENFEIG SIGNBMD) 1; —4 91QI, C'0UF4NY Th rx "a=lf.. *?W-IMW Completeness Check for Signs Project #/Name: _ARB2019-71: The Chiropractic Office wall sign Date Received at County: _6/21/19 Date Received in Design Planning: _6/24/19 Date of Checklist Check: _6/25/19 Assigned to/Date: _HNM 6/25/19 FEES M 3. ARB Review — Will the permanent sign(s) be constructed in an Entrance Corridor? (See the Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors) ❑ Yes ('Phis sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $129.00 Comprehensive Sign Review. See ARB requirements next pages) ® Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a Waive Fee Comprehensive Sign Review. See ARB requirements next pages) ❑ No ('This sign will not be constructed in an Entrance Corridor) $ 0.00 FEE TOTAL (Please add all the amounts checked in sections I — 3): $ WALL SIGNS ® A drawing, to scale, showing dimensions of the sign (length, height, depth). ® Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing ® The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also include these dimensions on the diagrams provided in Appendix B) ® Sign lettering and/or graphics in their proposed location. ® Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color illustration of the front and side elevations of the sign showing: o Indication of sign type (channel letters, cabinet, panel, etc.). o Indicate on the drawings the proposed materials and colors. Include standard color identification numbers (Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is attached. o Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint chips that accurately reflect the proposed colors are acceptable.) o Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17. o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it. ILLUMINATION REQUIREMENTS ❑ The location of proposed light fixtures identified on a plan and/or elevation ❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance. NOTES: application is complete