HomeMy WebLinkAboutWPO201600057 Plan - As-built 2019-06-28I
11
N
70
N
N
0
LO
N
N
0
N
00
0
a�
0
n
c
0
a
I
m
c0
0
It
0
o�
0
N
�I
m
W
Q
X
i
00
LO
00
M
0
U)
c
a�
X
w
W
I
I
N
2
00
LO
00
M
0
rn
PROTECT MANAGER J&dy St[rraC►��.i�i 9M3991
SURVEYED BY YS&M . DCOOD-Car"J5401 387-1153
DESIGN SUPERVISED BY J&CQrdA 1Qv"JM (540)248-I
DESIGNED BY ,.Adw-Utift ------------
V3
STATE SHEET N
BOLD AND/OR BOXED �od� ROUTE PROJECT
INFORMATION IS U •
AS -BUILT VA. •
NOTES:
CONSTRUCTED
CLAY LINER PER
CONTRACTOR
RECORD DRAWINGS
SD INLET
TOP=412.13
INV IN=411.38 15" RCP (NW)
INV OUT=411.36 15" RCP (SW)
YJ
rn
rn,
ozo
/IV v /IV- f / 1.00 l J rc L.r'wvVJ
0000-10 INV OUT=411.36 15" RCP (SE) I M
PERMANENT DRAINAGE -A-
-" r
EASEMENT>,
- - 41
CRET - - r - - - S DB. 4743, PG. 286 ,.!. I I l
_ r r� -
FIL TERRA kIEADWA�L - TOP OF RACK
TOP=415.13 5.0 - ; - _ 41- - - ; _ ELEV=414.39 _ FlL TERRA
INV OUT=413.73 4"PVC (NW) - = ' q 10 - - _ TO 16.20 I I 4
- 311
'�4CP' i _ - - -' PI/ INV OUT-414.90 4 PVC (NE) s, >;
/ - - _��
N �403 34 - _W V= 14-92 15"RCP I I
4",UNpER-D�A/N_ � �� �-1 ! _ __ __ _ _ _ - , - - SD INLET
[tom / 407- - �� -- 1 , WV-44 f 9 - .. I I
INV 414.98� \ _ a TOP=416.91
- _
/ 4 0 � O
15 RCP � - J - INV 1N-412.46 4 HDPE W)
1M�40&89, - j ' �=,; , �R/� I I INV 1N=412.51 4"PVC (NE)
- - - 40$ ROCK i i \ -410, - -_ - % 4"
--
- - N 4� ARMOR 0 NV OUT=411.95 15" RCP (SE)
�lNV=4 J� � ' /' i� 09 4w 1; �'° 1 � ' - �S„�,��, ; � �
_
i 15"RCP 141
SDMH
INV=407.86 TOP=417.72'
e`
/ TOP OF RISER=412.1U q2�- 8 PVC INV 1N=414.52 15" RCP (W) ��\ s'/pc, �►A '�
O INV=414.02 INV 1N=412.47 15"RCP SW �s�
� 8" HOLE /N STRUCTURE ( )
INV OUT=412.42 15" RCP (NE)
VA jI�u
INV=408.97 s
..r 1
`o EDGE OF WATER \
. o 4 :. ... OW H•
MEANELEV=406.45 Oilpre• 10 SD INLET W/GRATE ;
i
36"IDP/E i /i i i % STORMWATER MANAGEMENT TOP=419.54
�� + 1
N�Vt410R �1 I ' / i i i EASEMENT INV OUT=416.34 15" RCP (E)
DB. 5101, PG. 598 A SDMH
TOP=420.34 � ,I
CC��/1�laF �1 LEi1�}L ��� ,�� PID: 061 WO-OZ-00-00100 INV OUT=412.83 15" RCP (NE) ,
,ID.-IZ0-03-00-0 "Al ROSEWOOD VILLAGE L C
i /i i i i DB. 1175 PG- 520
-0 1ZdS, PG. 912 ":t•° x VIU" :VDOT
DB. /775, PG. 520 UTIL l TY EASEMENT
- -
G 286
�2 - - 500 GREENB1�'!ER DR DB �; 3 474 , PG.
SCALE 1 "=25'
S/M �! i ►�rJfplib� SUM AddrAmw CI[11, Liner,57 eci ications
.� Flf►1d1 QrOdVn� [� �d f0bWVA40" CawrwfAw
+. AN arms ore to to m Md as with oar ~8W am
& Bwk SoNow sftw Do MW wft cW jD Akd Wb or Zaaw >!911W MWOW So FeW MF-3 an
TNS Sw for CW Aw 4.WWAV " ar !t 60s" SONO I M me Aws ft OW Mw
re ulre�lys to 0 �h of & aw ft is 1 1w I aftmebw Ram a cowitew � &W is ow t***v&
If fSpO eld ft CAI► Filar swat k*Aw fir► ld! Cava( 11p SkiIr`sW►olrr Bnk Ejw&wibw
& A JWW of ceitlecli 14=Nwft o AfAAWO Of CSION& pad owe ft cW i6w for oNoreas
mire e0 1 d fib 1 4WDO*e SMdh*
T Two wte prkir 10 or a rV SWAP SfftCW&c&r VCW SMN MWy arlpinW ►or Cyr
b000ft" ow epprarer to nhm swig fw No ,
AL
Property
"1 est Method
yl)
"1' 4 llfi
(orequal)
. ITilit
Specification
i3t"t�t .t'i171f� �'
:_l,l,.k D-2434
c1n:sec,
I x 10
Plasticity fildex of
chly
NSTNI D.423 &.D-424
0(')
Not than 15
1_,irluid Limit ot'C` ay
AS'l'1I D-2 16
o,0
Not less t ian 30
clay Pzulwle4
P. Ing
AST-iM I3-427
0,0
NOL less. than 30
`lay• Crum action
_w1Sum D-2216
0.10
95(1,o cat' Standard Proctor Density
Sc)t v.,: Call. of.g 11,Y1117, 1938
1. DATE OF AS -BUILT SURVEY: 3ESM FEATURES RELATING TO CONSTRUCTION
2019-04-08 (BY TIMMONS GROUP) IR TO REGULATION AW CONTROL OF TRAFFIC
4AY BE SUBJECT TO CHANCE AS IEEMEC
2. BASIS OF HORIZONTAL & 4ECESSARY BY THE DEPARTMENT
VERTICAL DATUM DERIVED FROM AS -BUILT SURVEY
VDOT PROJECT 0000-104-119.
3. THIS EXHIBIT DOES NOT BY T I M M O N S GROUP
INDEPENDENTLY IMPLY CONFORMANCE. DATE OF SURVEY: APRIL 8, 2019
B Bl+*
4l5
4/0
405
............ ....... .......
...... .............
......... 40' MI
400
395 0 50 /�
/35
H -5' V
P�SF� ° ...... ......
PROPOSED'
. . ....... .f�rlsit� - n►ltt
. Eirlstliq
�
�..............
.....
TOP=40625 i
TOP=406.25 ......� ......
.... _. _
...�.'........._................'
....-... � ....
a
_
.
............... " ..... �QT.TQM
00.4 ........ . - .............
- .............
NOTE: IF ,EXISTING STRUCTURE (AT 4-2 LOCATION) IS DEEMED SOUND BY ENGINEERS
AND COUNTY ST AFF. IT MAY BE REUSED, AS IS, AT EXISTING ELEVATIONS.
CERTIFICATION OF AS -BUILT SURVEY
I, JOSEPH C. MEDLEY, A LICENSED LAND SURVEYOR IN THE COMMONWEALTH OF
VIRGINIA, DO HEREBY CERTIFY THAT THE AS -BUILT CONDITIONS DEPICTED
HEREIN ACCURATELY REFLECT THE CONSTRUCTION OF THE REFERENCED SITE.
0403003385 2019-0418
LICENSE NO. DATE
S,�,TH CF
I
o �
�JOSEPH C. MEDLEY
Lic. No.3385
04-18-19
SURV��o4
APPROVED
by the Albemarle County
Community Development Department
Date z. I? _ �9
File
EXHIBIT SHOWING
W
J
0
J
U
Q
LL
z
Cw
//G
0
Q
z
CQ
rGr'
I..L
W
Q
O
0
AS -BUILT CONDITIONS
OF STORMWATER
MANAGEMENT FACILITIES
HILLSDALE DRIVE
VDOT PROJECT 0000-104-119
ALBEMARLE COUNTY, VA
DATE: April 18, 2019 SCALE: AS SHOWN
SHEET 1 OF 1 J.N.:38581
DRAWN BY: DW3 CHECK BY: 1CM
UPDATE:
E
0
U
0
E
_ > E
� z 3
� o �
Q W z
Q O o
a _
w
01 Z �
a O > "?
z Z
= p �n
~ LL
0 � �
w
o
_ rj
o
rn Li
N 00
O
V
Lfl
J
w