HomeMy WebLinkAboutSDP201800091 Review Comments Minor Amendment 2019-06-28COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 Site Plan Amendment Review Project title: Oakleigh — Minor Site Plan Amendment Project file number: SDP201800091 Plan preparer: Steve Edwards[steve(a)edwarddesienstudio.com] 4936 Old Boonesboro Road, Lynchburg VA 24503 Alan Franklin, P.E., LLC [alan(a)alanfranklinpe.com] 427 Cranberry Lane, Crozet VA 22932 Owner or rep.: Oakleigh Albemarle LLC — 690 Berkmar Circle / Charlottesville, VA 22901 Plan received date: 20 Dec 2018 (Rev. 1) (Rev. 2) Date of comments: (Rev. 1) (Rev. 2) Plan Coordinator: Reviewer: SDP201800091 17 Apr 2019 8 Jun 2019 7 Feb 2019 10 May 2019; Rev. 13 Maw 28 Jun 2019 Paty Saternye John Anderson uompare approved impervious area (224,639 ft2) with proposed Amendment (232,586 ft2); a slight 3.4% increase. Amend VSMP/WPO Plan for this site plan, including VSMH Vol. 2 Appendix 5D worksheets. (Note: proposed routing of paved surface runoff directly into a Level-1 biofilter requires pre-treatment) Link: https://www.deq.vir ig•nia.lzov/Portals/O/DEO/Water/Publications/HndbkVolumeI.pdf - p. 3.11-14 and FIG. 3.11-7. "Like other infiltration basins, bioretention basins must always be preceded by a pretreatment facility to remove grease, oil, floatable organic material, and settleable solids..." SDP201700005, Sheet 2: (Rev. 1) Comment persists. WP02017-00023, Amendment 2, is under review. (Rev. 2) Addressed. VSMP /WPO approved 6/5/19. BREAKDOWN: BUILDINGS: ROADSlSI DEW AL KS: PAVED PARKINGIROADS SIDEWALKS PERVIOUS AREA;OPEN SPACE TOTAL SITE ACREAGE: -C 1.83 21% 2.7932.4 0,53 6% 3.67 42 % 384,286 8.822 100% NOTES: `. 1. The minimum required open space is 20% (per Section 20A.9.a.1 ). vA 2, Pendous arealOpen Space includes land w thin ROW and on any individual lot. 3. Common open space excludes land within ROW and on indmdual lots. 4. Lots include only those individual lots and nothing more. Engineering Review Comments Page 2 of 4 2. Include reference to approved VSMP/WPO for Oakleigh: list WPO201700023, Approved 3/26/18, as an associated plan. (Rev. 1) Addressed. Sheet 4 3. Provide gutter along Eckerson Court, from Int. with Nichols Court, to parking area entrance at proposed apartments. Ref. 18-4.12.15.g. Label curb and gutter using VDOT nomenclature, CG-7, for example. (Rev. 1) Partially addressed. Applicant response: `We are using CG-3 so we wouldn't have to install gutter on the access.' As follow-up: Please revise CG-3 to CG-6. Ref. 18-32.7.2.2.a. which references Chapter 14. Please ref. 14-412.B. which states VDOT standards apply. Please ref. VDOT Road Design Manual, Appendix B(1) -pg. B(1)-7, Table 1, Geometric Design Standards for Residential and Mixed Use Subdivision Streets (GS-SSAR), Curb and Gutter section. Gutter is required. It is optimistic to assume permeable pavers will be maintained over the life of this facility to the point design storm events do not cause runoff requiring drainage design that prevents flooding at low point, Eckerson Court. Provide CG-6. (Rev. 2) Comment unresolved. Applicant email with plan sheet attachments and comment response letter (6/3/2019 2:47 PM) reads in part, `I'm submitting only the sheets you (J. Anderson) commented on per our discussion this afternoon.' I cannot recall discussing this comment, specifically. Since comment response attached to 6/3 email states: `This has been addressed previously and no further revisions are required,' we need to discuss this comment. I apologize, appreciate reminder of specific points discussed, and hope to resolve, quickly. 4. Concrete dumpster pad does not appear to extend 8' from back face of enclosure gates to edge of asphalt surface. Revise to obtain min. 8' length, measured from back face of enclosure gates to edge of asphalt. Ref. 18-4.12.19. (Rev. 1) Addressed. 5. Dimension Eckerson Court travelway width. Provide width label. (Rev. 1) Addressed. 6. Revise Note 5., Restrictions/Requirements/Notes: to read `All travelways are private with public accc easements over them.' (Rev. 1) Not addressed. (Rev. 2) Withdrawn. Applicant response: `This note apparently needs to remain unchanged to conform to the approved ZMA-2016-00015 language according to Paty. We feel this comment is no longer an issue.' Engineering accepts Applicant response. 7. Label emergency access concrete apron /entrance at Rio Road using VDOT nomenclature (CG-9a, for example). Ref. Final Site Plan checklist, pg. 2, entrances and right-of-way improvements. (Rev. 1) Addressed. 8. SDP201700005, Oakleigh — Major Site Plan Amendment does not appear to include retaining wall design. Provide retaining wall design. See Final Site Plan and Retaining Wall checklists (attached to this Memo). (Rev. 1) Withdrawn. Applicant response: `Was provided to the County on 4/20/2017.' 9. Provide L X W (Typ.) dimensions for the three proposed parking spaces just west of the emergency access. (Rev. 1) NA. Spaces removed. 10. Provide auto turn for typical passenger vehicles at Sta. 12+50f, Eckerson Ct, to show that a car exiting may pass a car entering without striking curb or parked vehicles, with at least 2' clearance between vehicles. Revise design to provide minimum 2' clearance between two typ. passenger vehicles at this location. (Rev. 1) Withdrawn. Applicant response: `This is no longer an issue with circulation being one way towards the dumpster.' 11. Label travelway width between Sta. 12+50(f) and dumpsters, Eckerson Court (appears to be —14' FC-FC). (Rev. 1) Addressed. 12. This section of travelway is too narrow for two-way travel. Provide signs indicating `one-way' travel unless inconsistent with site plan requirements or Albemarle County Planning Division review, or policy. (Rev. 1) Addressed. 13. Provide auto -turn for waste management vehicle (Typ.) to illustrate how WM vehicles may perform reverse movement to exit this area without striking pedestrians, curbs, or parked vehicles. (Rev. 1) Addressed. 14. Revise subterranean parking drive aisle dimension to 24' (apparent typo). (Rev. 1) Addressed. 15. Revise 9' w (non-HC) parking space (adjacent to 8' w HC space) to 10' width. Ref. 18-4.12.16.c.1. (Rev. 1) Addressed. 16. Label sidewalk width, for walk located north of Eckerson Court. (Rev. 1) Addressed. Engineering Review Comments Page 3 of 4 17. Provide curb cut required for drainage to bioretention midway along 8 parking spaces south of apartments. (Rev. 1) Addressed. 18. Provide bioretention basin pre-treatment for this (asphalt surface) storm runoff, item above. (Rev. 1) Partially addressed. Applicant response: `Pre-treatment for this bioretention basin is based on the old stormwater regulations. It is a forebay as shown on the plans.' Additional comments possible with VSMP /WPO2017-00023, Amendment 2. Comments will be based on VSMH, First Edit., 1999, Min. Std. 3.11. (Rev. 2) Addressed. VSMP /WPO approved 6/5/19. 19. Provide `do not enter' sign at south exit of subterranean parking. Alternatively, revise travelway width, north side of apartments to 20', min. Ref. 18-4.12.17.c.1.-2. (Rev. 1) Addressed. Sheet 5 20. Provide storm inlets and conveyance from paved surface of Eckerson Court. Please ref. proposed profile. From proposed H.P. Sta. 11+20, surface runoff flows west, without any inlets on the travelway. This runoff bypasses the parking area fronting east side of proposed apartments, and washes into a dumpster enclosure. Provide VDOT storm drainage design, for both culvert pipes and inlets. Eckerson may (likely will) flood and present hazard under proposed curb without gutter and inlet design. (Rev. 1) Not addFeSSed. Peffaeable paN,er-s are likely to blind with debris if iffipr-epefly maintained. in that ease, stiffa f+tfi 9 has fie E*itlet. ReEji:iest GG inlet deSigft. Re6efM:Aefid 120' pipe 40M ifilet at L.P. Rekef%fi Q. Sta. 124-46 (�=) to S4. 142. Thefe is suffieient grade for- mild slope between these peif4s. Flooding at the lwA point i'a .,t+aaa fesidents e fthe apartment ple* Withdrawn. Sheet 5 label ref. to 8"AOC trench drain provides second tier drainage in event permeable pavers (Eckerson Ct.) are infrequently maintained. 21. Revise 1/8 (4" curb) detail to VDOT CG-7. Ref. 2016 Road and Bridge Standard, CG-7, 201.04, Rev. 9/06. (Rev. 1) Partially addressed. As follow-up: Provide barrier -type curb appropriate to design speed. Ref. Sheet 8, VDOT CG-3 detail, Note 5. Also, item 3. Comment is revised to request design provide CG-6. (Rev. 1, Rev. 5/13) Please provide CG-2 label if item 3 (once discussed internally) is withdrawn. Reviewer cannot locate CG-2 curb type label for Eckerson Ct. Curb type will be either CG-2 or CG-6 (see item 3). 22. Provide dumpster pad detail. Ref. 18-4.12.19. Specify /provide minimum 4" stone base, 6" concrete depth, 3000psi at 28 days, with minimum grid of wire reinforcing or #4 bars at 12" on center. Final Site Plan checklist, p. 3, parking and circulation, item 8. (Rev. 1) Addressed. 23. Revise proposed grade so that Eckerson Court storm runoff does not wash through dumpster pad enclosure. Collect and convey storm runoff to avoid spread greater than '/2 travel lane width + gutter pan. (Rev. 1) Addressed. Sheet 8: 24. Revise K ag value, Eckerson Court, PVI Sta. 12+46 (K proposed — 5.00) to nearly approximate approved site plan Ksag PVI Sta. 12+86, K—12.00. Recommend Ksag — 15.00 as a design target. (Rev. 1) Not addressed. , private stf eet beeemes more like a tfavelway and dr-apped the pr-ivate read standards and feel is adeqii Streets) whieh states VDOT- standafds apply. Please addfess. Reqttifed fef site plan . Withdrawn. Sta. 12+46 low point is beyond radius return at entrance to apartment complex parking area. Speeds are reduced. It is borderline beyond travelway, and may reasonably be argued beyond travelway limits. 25. Provide emergency access section (detail). (Rev. 1) Addressed. 26. Provide grasspave detail. (Rev. 1) Addressed. 27. Detail D/8: Include VDOT Class A3 General concrete design parameters; i.e., compressive strength, slump, air, etc. Link: http://www.virginiadot.org/VDOTBusiness/asset upload_fi1e41_3529.pdf , p. C-18. (Rev. 1) . This is a speeifieation. item missed en pfief feview that does not altef design and fequires lifnited fevi appeafs basis of applieant fespense� 'This detail has been appfaved twiee iews and we feel doesn't r-eqttife being addressed a4 this .' Addressed. Engineering Review Comments Page 4 of 4 28. Provide S.I Storey Streetguard (guardrail) detail, as well as technical information that demonstrates this product is equivalent to VDOT Std. in terms of barrier protection. (Rev. 1) Addressed. 29. Nichols Court, Sta. 11+00(±): provide cross drain (VDOT CD-1, 2) at cut/fill transition. (Rev. 1) Withdrawn. Review error: `This road has been built. This cannot be added.' 30. Note: An approved VSMP Plan Amendment is required prior to Site Plan Amendment approval. (Rev. 1) Comment persists. Applicant response: `Noted.' VSMP/WPO 2017-00023 is under review. (Rev. 2) Addressed. VSMP /WPO approved 6/5/19. Please feel free to call if any questions. Thank you J. Anderson 434.296-5832 -0069 SDP201800091 Oakleigh Minor 062819rev2.docx