Loading...
HomeMy WebLinkAboutSDP201900028 Review Comments Major Amendment, Final Site Plan 2019-07-02COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 July 02, 2019 Eric Woolley, P.E. Wooley Engineering 220 E. High Street Charlottesville, VA 22902 ewoolley@woolley-eng.com RE: SDP201900028 University of Virginia Research Park: Town Center 4 — Major Site Plan Amendment Dear Mr. Woolley: The Site Review Committee has reviewed the development proposal referenced above. Initial comments from the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Planning Services (Planner) Albemarle County Engineering Services (Engineer) (attached) Albemarle County Architectural Review Board (ARB) (attached) Albemarle County Information Services (E911) Albemarle County Building Inspections (attached) Albemarle County Department of Fire Rescue Albemarle County Service Authority (attached) Virginia Department of Transportation (attached) Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that will be required to be resolved prior approval of the major site plan amendment. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, Cameron Langille Senior Planner Albemarle County Planning Services (Planner) — Cameron Langille, blan ig lle(iDalbemarle.org — Required changes: 1. [General Comment] On Sheet C 1.0, please fix the text overlap in the box titled "Site Development Plans." 2. [32.5.2 (a)] On Sheet C 1.0, please add each Tax Map Parcel (TMP) number that is affected by this amendment. This includes TMPs 03200-00-00-019J1, 03200-00-00-006A2, 03200-00-00-006RO and 03200-00-00-019G0. 3. [32.5.2 (a)] On all applicable sheets, please clearly identify the existing property boundaries within the scope of the project and label them with the TMP, names of the owner, zoning district, and most recently recorded instrument. 4. [32.5.2 (a)] On Sheet C 1.0, please state that the portions of the properties lie within the Managed and Preserved Steep Slopes Overlay Districts. [32.5.2 (a)] On Sheet C3.0, please revise the Legend so that it identifies both Managed and Preserved Steep Slopes. a. Amend Sheet C3.0 so that areas of Managed and Preserved Steep Slopes are differentiated and identified. b. On Sheet C3.0, state the source used to identify areas where Managed and Preserved Steep Slopes currently exist. 6. [32.5.2 (a)] Please add a note to Sheet C0.0 that states the instrument numbers (deed book and pages) for all recorded plats and deeds associated each parcel within the development. 7. [32.5.2 (b)] Please verify the proposed Town Center 4 building footprint. According to SDP201600051, the proposed building footprint was 27, 683 square feet and a gross total square footage of 108, 568 sq. ft. Under "Proposed Building Statistics" on Sheet C1.0, the footprint has now been reduced to 27,201 sq. ft. but eh gross building square footage is still 108,568 sq. ft. a. If the gross building square footage is changing, please revise the figure provided under Note 7 on Sheet C1.0 next to "Gross Building Square Footage." b. If the gross building square footage is changing, please revise the figure provided under Note 13 on Sheet C 1.0 next to "Town Center Four — Approved Buildings (sf)." c. If the gross building square footage is changing, please revise the figure provided under Note 13 on Sheet C 1.0 for the total approved buildings (sf). d. If the gross building square footage is changing, please revise the figure provided under Note 13 on Sheet C 1.0 for the total remaining approved GSF column. [32.5.2 (a)] Please state the application numbers of all approved Special Use Permit and Zoning Map Amendments (ZMA) that apply to the development in Note 5 on Sheet C 1.0: a. The properties are subject to the approved conditions of Special Use Permits SP200800015, SP200800062, SP200800063, and SP200800064. 9. [32.5.2 (n)] On Sheet C4.0, please label all proposed features within and next to the lawn area to the north of Building 4. Are the gray items sidewalks or some other sort of paths? Are the white areas grass cover? a. Please provide labels in the white area south of Building 4 explaining whether the white area is grass cover, pavement, etc. b. State the paving materials for all walkways in the lawn area. c. State the paving materials for the hatched area next to Building 4. 10. [32.5.2 (j)] Please label all existing water, sewer and drainage easements by type and include a size/width measurement. State the deed book and page for the recorded instrument number in each existing easement label. 11. [32.5.2 (k)] Verify that all necessary easements for water, sewer, and drainage currently exist and no new easements are needed. If new easements are required, an easement plat application must be submitted, reviewed, approved and recorded prior to final site plan approval for all proposed easements. b. Once the easement plat is recorded, the final site plan must be revised to show the recorded instrument number for the easement plat (deed book and page number). The newly created easements will need to be labeled with the instrument number, easement type, width dimensions, and whether it is public or private. 12. [32.5.2 (n)] ADA compliant striping must be provided across all parking lot drive aisles where handicap accessible parking spaces are provided on opposite sides of the travelway. For example, the sidewalk ramps to the west of Building 4 which connect to the 8' asphalt trail are not currently connected by striping in two drive aisle locations. The ramps on either side of the drive aisle south of Building 4 also do not have striping. 13. [32.5.2 (n)] Please state the height of all proposed fences and retaining walls in the labels used on the drawings. Profile view details of all proposed fences, retaining walls, and constructed screening measures will be required with the final site plan. Each will need to show the types of materials used and dimensions. c. See Engineering Division and Inspections Division comments for additional details on retaining wall requirements. Add the notes specified by Inspections to the applicable drawings mentioned in their comments. 14. [32.7.91 The landscape schedule on Sheet LLO lists the incorrect quantities for the following items: a. Only 16 AC (Acer rubrum) are shown, not 74. b. Only 9 BN (Betula nigra) are shown, not 28. 15. [32.7.9.91 Please add a note to the Sheet LLO stating "All landscaping shall be installed by the first planting season following the issuance of the first certificate of occupancy within the development." 16. [32.7.8 and 4.171 Please address the following related to site lighting: a. [4.17.4 (a)] On Sheet SL2.0 next to each manufacturer cut -sheet, please state the letter from the luminaire schedule on Sheet SL 1.0 that identifies which cut -sheet pertains to each luminaire. b. [4.17.4 (a)] All proposed outdoor luminaries exceeding 3,000 lumens must be full -cutoff fixtures. The cut sheets provided on Sheet SL2.0 do not clearly verify that this is true for the following luminaires proposed on site: luminaire A, luminaire G, luminaire G2, luminaire OG1, luminaire EXP, luminaire AE. Please provide documentation from the manufacturers that all fixtures will be full -cutoff. c. Please state the pole height of all outdoor luminaires in the table on Sheet SL1.0. d. [4.17.4 (b)] Add a note to Sheet SL1.0 stating "The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half (%) foot candle." e. Please add a note to Sheet SL1.0 which states "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half footcandle." Please contact Cameron Langille at the Department of Community Development at blan ig llegalbemarle.org or 296- 5832 ext. 3432 for further information. Comments From Other Reviewers: Albemarle County Engineering Services (Engineer) — John Anderson, janderson2&albemarle.org — Engineering review still underway. Comments or approvals will be forwarded to the applicant upon receipt. Albemarle County Architectural Review Board (ARB) — Margaret Maliszewski, mmaliszewskikalbemarle.org — No Objection, see attached. Albemarle County Information Services (E911) — Andy Slack, aslack@,albemarle.org, No Objection. Albemarle County Building Inspections — Michael Dellinger, mdellinger(kalbemarle.org — Requested Changes, see attached. Albemarle County Department of Fire Rescue — Shawn Maddox, smaddox(calbemarle.org — Fire Rescue review still underway. Comments or approvals will be forwarded to the applicant upon receipt. Albemarle County Service Authority — Richard Nelson, rnelson(&,,serviceauthori ..org — See attached recommendation. Virginia Department of Transportation — Willis Bedsaul, willis.bedsaulkvdot.virginia.gov — No Objection, see attached. Review Comments for SDP201900028 Major Amendment Project Name: University of Virginia Research Park: Town Center Four - Major Date Completed: Monday: June 24. 2019 � DepartmentfDivisionfAgency: Review Status: Reviewer: Margaret Maliszewski CDD ARB No Objection Page: County of Albemarle Printed On: F57710 192 19 Review Comments for SDP201900028 Major Amendment Project Name: University of Virginia Research Park: Town Center Four - Major Date Completed: Monday: June 24. 2019 1 DepartmentfDivisionfAgency: Review Status: Reviewer: Michael Dellinger Add the following notes_ Other than that, no objection_ CDD Inspections Requested Changes Add the following note to the general notes page: Retaining },valls greater than 3 feet in height require a separate briilding permit_ Walls exceeding 4 feet in height require a stamped engineered design also 'Halls require inspections as outlined in the U BC_ Add the following note to the general notes page: Accessible parking spaces and access isles shall not have a surface slope greater than 1:48_ Access isles shall be at the same level as the parking space they serve_ Add the following note to the general notes page: ALL water lines, sewer lines, and fire lines from the main to the strricture MUST have a 5risrial inspection performed by the buildng department_ Add the following to the general notes page: All roof drains shall discharge in a manner not to carise a priblic nriisance and not over side,,valks Page: County of Albemarle Printed On: F57710 192 19 Cameron Langille From: Richard Nelson <rnelson@serviceauthority.org> Sent: Friday, June 28, 2019 3:36 PM To: Cameron Langille Subject: SDP201900028 UVA Research Park Town Center Four - Major Amendment Cameron, SDP201900028 UVA Research Park Town Center Four - Major Amendment is currently under review. Thanks, Richard Nelson Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (434) 977-4511 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange ROad Culpeper, Virginia 22701 Charles A. Kilpatrick, P.E. Commissioner June 20, 2019 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Cameron Langille Re: UVA Research Park Town Center Four- Major Site Plan Amendment SDP-2019-00028 Review #1 Dear Mr. Langille: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Woolley Engineering, dated May 20, 2019, and find it to be generally acceptable. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the VDOT Charlottesville Residency Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, ot� 4axL---- Adam J. Moore, P.E. Area Land Use Engineer Culpeper District VirginiaDOT.org WE KEEP VIRGINIA MOVING