HomeMy WebLinkAboutSDP201900035 Review Comments Major Amendment, Final Site Plan 2019-07-17'AL
� IRGStr«
County of Albemarle
Department of Community Development
Memorandum
To: Herb White
From: Tori Kanellopoulos- Planner
Division: Planning Services
Date: July 17, 2019
Subject: SDP201900035 — Major Amendment — Stonefield Block G
The County of Albemarle Planning Division will grant or recommend approval of the Major Site
Plan Amendment referenced above once the following comments have been addressed: [Each
comment is preceded by the applicable reference, which is to the Zoning Ordinance otherwise
specified.]
Planning (Tori Kanellopoulos)
1. Fees: It appears the $215 mailing fee has not been paid. Payment is required prior to
site plan approval.
2. To note: the most important design comment is that the drive-thru needs to be moved
in order to address both Planning and Engineering comments.
3. [18-5.1.60] Drive-thru requirements:
a. [18-5.1.60(e)]: "Each drive -through lane shall be separated from any pedestrian
travelway, except where a pedestrian travelway crosses the drive -through lane
as provided in subsection (f), and any vehicular travel areas, by a planting strip at
least five (5) feet in width." Provide a 5-foot or greater planting strip between
the drive -through lane and travelway.
b. [18-5.1.60(i)] "Each entrance to a drive -through lane shall be more than fifty (50)
feet from any intersection with a public or private street or travelway without
parking." Design changes are needed to meet this requirement. It is
recommended to move the drive-thru lane to the other side, so that it is farther
from the intersection and queuing concerns are reduced.
c. [18-5.1.60(j)] "Each drive -through lane shall be a minimum of one hundred (100)
feet in length measured from the center of the first window or service point. This
length may be reduced if a study is submitted and approved by the director of
community development or his designee demonstrating that a shorter length will
be sufficient for a particular use." Either increase the length of the drive-thru
lane, or provide justification for a shorter drive-thru lane. For example, use other
comparable existing uses to show that queuing will not create an issue.
d. [18-5.1.60(k)] "Each drive -through lane shall extend at least twenty (20) feet
beyond the drive -through window." Extend the drive-thru lane at least 20 feet
beyond the window.
4. [18-4.12] and [Code of Development] Parking requirements:
a. [18-4.12.6] and [COD] Number of spaces: The previously approved site plan for
this Block (SDP2014-65) shows 157 required spaces and 226 provided spaces.
This site plan amendment shows 172 required spaces and 224 provided spaces.
Please indicate if spaces are being removed, or were not completed.
b. [18-4.12.6] and [COD] Number of spaces: The addition of the Bank adds a
requirement of an additional 16 spaces. Since the parking for Block G was
previously calculated using all of the buildings in the Block, it appears that there
is a shared parking agreement. Please indicate how the Bank required parking is
being met, as there are not 16 spaces shown on this site plan amendment.
c. [18-4.12.10] Shared parking: If shared parking is being provided, please include
the shared parking agreement. This may need to be updated to include the Bank
and site plan amendment, depending on how it is worded and where it currently
covers.
5. [18-4.12.17(c)] Travel lanes: Defer to Engineering comments: Travelway width needs to
be increased to 16 feet. This requirement may change depending on how the drive-thru
is rearranged to meet 18-5.1.60 standards.
6. [18-4.12.13] and [18-4.12.18] Loading spaces: It appears there are four existing loading
spaces on the approved site plan SDP2015-65, one for each of the buildings. It is unclear
where the loading space approved with building G4 is now located or if it remains.
Please label the loading space and clarify if it is for both buildings.
7. [18-4.12.19] Dumpster pads: It is unclear where the existing dumpster pad for G4 is now
located. Please label and indicate if building G4 and the proposed building will be
sharing a dumpster. Ensure dumpster pad meets design standards.
8. [18-32.5] and [18-32.6]: Notes required:
a. Include the height of the proposed building (bank).
b. Add the approved rezonings to Sheet 1, which are listed on the approved site
plan SDP2014-65. These include ZMA2001-7 and the rezoning amendments that
followed.
c. Add a note that the site is subject to proffers per ZMA2001-7.
d. There are various waivers and modifications that have been approved for the
Stonefield development, which are printed on sheets on site plan SDP2014-65.
Either include these waivers/modifications, or reference that there are
waivers/modifications approved for this development.
There was a special exception request on the Board's consent agenda for July
17, 2019, which was approved. This is to allow for the drive-thru use for this
particular site only in Stonefield. Please reference on the site plan as a note.
Such as: "Drive-thru use permitted through special exception request, approved
by the Board of Supervisors on July 17, 2019". You may also include a sheet
showing the approved/signed resolution. Staff will provide this signed resolution.
Include an updated uses table for Stonefield. This was shown on Sheet 3 on
SDP2014-65. Please note that while there are pending applications for Blocks C
and D of Stonefield, those site plans have not yet been approved.
g. Add the Airport Impact Area to the "Overlays".
h. Add a note that the utilities are ACSA.
9. [18-4.17] Lighting: Please indicate if any lights have been added, removed, or modified
since the approved site plan SDP2014-65. If so, please submit a new lighting plan
showing the changes.
10. [18-32.5.2(i)] Streets: Include the ROW and Deed Book/Page Number (if applicable) for
all existing streets.
11. [18-32.5.2(1)] Utilities: There do not appear to be any new easements shown on the site
plan. Please confirm. If there are any new non-ACSA easements, an easement plat will
be required prior to site plan approval.
12. [18-32.7.2.3] Sidewalks: Please show the sidewalks/materials more clearly. It is difficult
to see where sidewalks are proposed. Sidewalks should provide safe access and
connectivity to this building and to existing buildings in this Block. Crosswalks should
also be provided, as indicated in Engineering comments.
13. [18-32.7.9.4] Landscape plan: Include the conservation checklist.
14. [18-32.7.9] Landscape plan: Please indicate which requirement (e.g. landscaping parking
areas) the two new trees are meeting.
15. [18-32.7.9.6] Landscaping within parking areas: Include the area of the proposed
parking lot. For parking areas of 5 or more spaces, at least 5 percent must be
landscaped.
16. [18-32.7.9.8] Tree canopy: Show how this requirement is being met (10% for
commercial uses). It appears to have already been more than met on the SDP2014-65
site plan, however that needs to be shown on this site plan.
17. [18-32.7.9] Landscape plan: Please include full updated landscape tables on this site
plan (Sheet 23 on SDP2014-65). This is to ensure that canopy and parking landscaping
requirements are being met, as they were previously calculated for the entire Block G.
Engineering (John Anderson)
1. See attached review comments dated July 14, 2019.
VDOT (Adam Moore)
1. No objection. See attached letter dated July 16, 2019.
ACSA (Richard Nelson)
1. Submit 3 hard copies and 1 PDF copy to ACSA for review, ATTN: Alex Morrison.
2. Submit water and sewer data sheets.
Fire/Rescue (Shawn Maddox)
1. Travel way must be 20' of unobstructed travel width. This must be increased to 26' if the
height of the building will exceed 30'.
2. Move the hydrant closer to the FDC on the site, or relocate the FDC to the area of the
hydrant. The current configuration will require emergency apparatus to drive past the
building to connect to a water supply then the FDC.
3. A knox box will be required. A note on the plans indicating this requirement and that
location can be coordinate with the fire marshal's office will suffice.
4. A fire flow test will be required prior to final acceptance.
Inspections (Michael Dellinger)
1. Due to distance proximity between buildings, fire rated construction may be required.
Coordinate with architect of record.
2. Add the following note to the general notes page: Accessible parking spaces and access
isles shall not have a surface slope greater than 1:48. Access isles shall be at the same
level as the parking space they serve.
3. Add the following note to the general notes page: ALL water lines, sewer lines, and fire
lines from the main to the structure MUST have a visual inspection performed by the
building department.
4. Add the following to the general notes page: All roof drains shall discharge in a manner
not to cause a public nuisance and not over sidewalks.
ARB (Heather McMahon)
Note that a Certificate of Appropriateness is required prior to approval of this Major
Amendment.
The ARB reviewed the Final Site Plan/Major Amendment at its meeting on June 17, 2019 and
made the following comments:
1. Note that the approved landscape plan for Block G (as shown on SDP2014-65) is in
violation until the approved landscaping is planted.
2. Revise the "exterior finishes" sheet to name the color of the Hardie Panel.
3. Provide window -glass specifications for review.
4. Note that a full site plan (for ARB review) will be required with a Major Amendment to a
Site Plan application.
5. Provide the standard mechanical equipment note to future site plans: Visibility of all
mechanical equipment from the Entrance Corridor shall be eliminated.
6. Rectify discrepancies between the luminaire schedule and manufacturer's cut sheets for
each model in terms of lumens output and color temperatures.
7. Provide the standard light note on a revised lighting plan: Each outdoor luminaire
equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff
luminaire and shall be arranged or shielded to reflect light away from adjoining
residential districts and away from adjacent roads. The spillover of lighting from
luminaires onto public roads and property in residential or rural areas zoning districts
shall not exceed one half footcandle.
8. Revise the landscape schedule to accurately reflect the total number of trees proposed
in Block G.
9. Note that a separate sign application will be required and sign design is subject to the
approved criteria in the Stonefield Block G Comprehensive Sign Plan.
In addition, staff provides the following comments to this submission:
1. Include the revised lighting plan with this civil site plan set.
E911 (Andrew Slack)
1. No objection.
Health Department (Alan Mazurowski)
1. No objection. See attached letter dated July 16, 2019.