Loading...
HomeMy WebLinkAboutFDP201900011 Plan - Other (not approved) 2019-07-24I o- I I --- • FEMA FLOODWAY I I I \ I � I PL PL I II I EXISTING \\ \ I I PL PL — • ACCESS ROAD \ \\ GRAVEL ACCESS I PL J— \ \ ROAD (21 A) SEE OL EXISTING \ \ DETAIL 4/C6 L PL i EASEMENT (TYP) \ PL I II PL EXISTING FENCING PL I P` �' 1 a I I I I PL PL > / I i � � I s02 _ EXISTING v' SUMP / GATE FENCE con o �, / 503 PARKING LOT (21 A) 'n / _ WATERTIGHT MANHOLE (TYP) EXISTING O > CROZET FET DRAIN o, PS NO.4 -' VALVE VAULT ODOR / a FEMA 100-YEAR CONTROL UNIT \ FLOODPLAIN ------------- a _505_ 504 2/- - - - - - - 0 0 C3 EXISTING 505 MANHOLE z DESIGN 100-YEAR CRETE C RB FET INFLOW AND _ - - _ - - - - - - - - - - - - - - --J�_-- FLOODPLAIN- -- FLUSH VALVE VAULT - - - - - - - - - - - - - - - EXISTING / i \ SO>GENERATOR EXISTING ` FET-1 PERIMET FUEL TANK /C3 509 510 �510 v 513 ` i53—� �F\ \\ I l s °E\Pt-------------- RL 1 10, n 20 \ I \ I a I I S ITE PLAN SCALE:1 20' PRELIMINARY 60% MAY 2019 J J J zz SCALE RIVANNA WATER AND SEWER AUTHORITY CIVIL PROJECT NO.: 01713.01 DESIGNED JM APPROVED GREELEYa JD HANSEN �— DRAWN DRH 20 0 20 40 FT DWG' C 2 9020 STONY POINT PARKWAY, SUITE 475 1"=20' � RICHMOND, VIRGINIA 23235 CHECKED RJC CROZET FLOW EQAULIZATION TANK SHEET: ---- OF XX ' NO. DATE APPD REVISION AND PUMPING STATION UPGRADES SITE PLAN DATE: AUGUST 2019 fi REV: 0 _ I I LL I L ` I I PL I II II PL OL PL \ I I I \ \ PL a I I I \ I I PL � L PL ' EXISTING FENCING \ I I PL I j i PL a I I I ,y PL I L PL Plot { i GRAVEL ACCESS �i ROAD AND I PARKING LOT - EXISTING / Um SUMP � MANHOLE (TYP) \MH-3 \ i SEE DETAIL 5/C6 MH-2 FET DRAIN ODOR 24" DI VALVE VAULT I CONTROL UNIT S \ w EXISTING 12+00 $ D CROZET _ 12" DRAI o. PLUG \ PS NO.4 24" DI I \ \ SEE DETAIL 2/C6 00 — — EXISTING 18" DI 24" DI ---r-----— — — — — — — — — — — I MH-5 o / / � 24 DI SAS SAN S N MH-1 z EXISTING 13+00 MANHOLE` -50 DOG HOUSE ABANDONED 18" 12" FILL � + $ _ s ( ) SEE NOTE 2 FET INFLOW AND — — — — — — — - Je— — — — _SEE DETAIL 3/C6 FLUSH VALVE VAULT ------- FET— 1 ------- \ / — — > V D 1 :+0- EXISTING ,u GENERATOR ri \ FLU H I 12" FM SEE DETAIL 2/C5 EXISTNG FUELTANK DO 51 / LO i � 51 4 . 530 515 �of c of P� I 1 -A000, , I �oEl h � \�I I \ -- NOTES. 1. SEE DWG C5 FOR 12" OVERFLOW, 12" DRAIN, 24" \ I \ I h I I SEWER, AND 12" FM PROFILES. 2. UTILITIES SHOWN AS ABANDONED MAY BE REMOVED AS NEEDED TO INSTALL NEW CONSTRUCTION AFTER CONFIMING UTILITY HAS BEEN ABANDONED. YARD PIPING PLAN "_' PRELIMINARY 60% SCALE. 1 20 z MAY 2019 -L zz SCALE RIVANNA WATER AND SEWER AUTHORITY CIVIL PROJECT NO.: 01713.01 DESIGNED JM APPROVED OWN GREELEYa JD HANSEN �— DRAWN DRH 20 0 20 40 FT DWG' C 4 9020 STONY POINT PARKWAY, SUITE 475 1"=20' � RICHMOND, VIRGINIA 23235 CHECKED RJC CROZET FLOW EQAULIZATION TANK SHEET: ---- OF XX NO. DATE APPD REVISION AND PUMPING STATION UPGRADES YARD PIPING PLAN DATE: AUGUST 2019 REV: 0