HomeMy WebLinkAboutSDP201900041 Review Comments Initial Site Plan 2019-08-06COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902-4596
Phone (434) 296-5832 Fax (434) 972-4126
August 6, 2019
Michael Myers, P.E., C.F.M. — 30 Scale, LLC
871 Justin Drive, Palmyra, VA 22911
mike600scale.com / (434)-242-2866
RE: SRC Comment Letter for SDP-2019-00041
(Initial Site Plan: Albemarle Limousine / 1895 Avon Street Extended)
Mr. Myers:
The Planner for the Planning Division of the Albemarle County Community Development Department (CDD) and
other members of the Site Review Committee (SRC) have reviewed the development proposal referenced above.
Initial review comments from the following SRC members are attached:
Albemarle County Planning Services (Planner)
Albemarle County Engineering Services (Engineer) — (attached)
Albemarle County Information Services (E911) — (attached)
Albemarle County Building Inspections — (attached)
Albemarle County Department of Fire Rescue — (attached)
Virginia Department of Transportation (VDOT) — (attached)
Albemarle County Service Authority (ACSA) — (attached)
Each comment is preceded by the applicable reference to Chapter 18 of the Albemarle County Code (Zoning
Ordinance / "Z.O.") unless otherwise specified. The following comments reflect information available at the time
the development proposal was reviewed, and should not be considered final. Additional comments or conditions
may be added or eliminated based on further review.
The Planner will either approve with conditions or deny the Initial Site Plan within 15 days of the Site Review
Committee Meeting.
Please contact me at your earliest convenience if you have questions or require additional information or assistance
prior to the SRC Meeting on Thursday, August 8, or any time after.
Sincerely,
�amL�X�v�
Tim Pada mo, AICP
Senior Planner
(434)-296-5832 x 3088 / tpadalinokalbemarle.org
Page 1 of 3
Community Development Department — Planning:
Contact: Tim Padalino / ttpadalinokalbemarle.org
1. [Z.O.32.3.1.(c), 32.4.2.5.(a), 33.40.C, and SP2018-07 and SP2018-08 Conceptual Plan and Conditions of
Approval] : CDD staff has reviewed this Initial Site Plan and has made the following findings regarding
compliance with the applicable Special Use Permit (SP) Conditions of Approval:
a. The proposed Site Plan shown on Sheet 4 appears to be in general accord with the Conceptual Plan in
regards to SP Conditions of Approval #l.a, Lc, Ld, and Le.
b. The proposed Site Plan shown on Sheet 4 is potentially in general accord with the Conceptual Plan in
regards to SP Condition of Approval #1.b ("Screening comprised of a screen fence (sliding gate),
screening fence, and landscaping"). CDD-Planning staff is coordinating with CDD-Zoning staff to
determine if the proposed location of the "opaque wooden gate" as shown on Sheet 4 (at the rear corner
of the proposed building addition) is in general accord with the "proposed sliding gate" shown on the
Conceptual Plan (near the front corner of the existing building).
c. The proposed Site Plan shown on Sheet 4 is in general accord with SP Condition of Approval #2;
however, please see VDOT review comments regarding required modifications to the design and
location of the proposed sidewalk.
d. The proposed Site Plan shown on Sheet 4 is potentially in general accord with SP Condition of
Approval #3; this condition does not have to be addressed and resolved until the time of Building
Permit review.
e. The proposed Site Plan shown on Sheet 4 is potentially in general accord with SP Condition of
Approval #2; this condition does not have to be addressed and resolved until the time of Landscape
Plan review (during the Final Site Plan review process).
2. [SP2018-07 and SP2018-08 Special Exceptions Conditions of Approval]: CDD staff has reviewed this Initial
Site Plan and has made the following findings regarding compliance with the applicable Special Exception (SE)
Conditions of Approval:
a. The proposed Site Plan shown on Sheet 4 appears to be in general accord with all SE Conditions of
Approval.
b. Staff requests, but does not require, that the following note be added to Sheet 4 and also added to the
Landscape Plan (during the Final Site Plan review process): "The existing canopy trees within the side
yard setback area that currently provide screening shall be protected during construction, and shall be
maintained to increase and preserve the health of the trees — including but not limited to cutting and/or
removing the vines growing up the tree trunks — as requested by the Albemarle County Planning
Commission during the public hearing to discuss Special Exception requests to modify the side yard
setback and disturbance buffer zone on September 25, 2018. "
[Z.O. 32.5.2(a)]: Please revise the Zoning information as follows:
a. In the "Project Narrative" on Sheet 1, revise the second paragraph to reference "two special exceptions"
instead of "a special exception," and add the date of approval of those special exceptions (11/14/2018)
for reference.
b. In the "Ordinance Tabulations" table on Sheet 2, revise the "Side and Rear — Minimum" information in
the "Yards" section to reference the two Special Exceptions approved on I l/14/2018 (involving
modifications to the side yard setback and disturbance buffer zone).
4. [Z.O.32.5.2.(e)]: Please show and quantify proposed limits of disturbance. (See CDD-Engineering comments.)
5. [Z.O.32.5.2.(b) and 32.5.2.(k)]: Site Plan Note 8 on Sheet 4 references an existing sewer lateral that will be
utilized for service to 1895 Avon Street Extended. Please add a reference to this existing sewer lateral and
available sewer service in the "Property Information" section of the "Ordinance Tabulations" table on Sheet 2.
Currently, the "ACSA Jurisdictional Area Note" portion of that section references water utility service but does
not mention wastewater/sewer utility service.
6. [Z.O. 32.5.2.(p), 32.6.2.(j), and 32.7.91: (Advisory only; no revision to Initial Site Plan is necessary) — An
approved Landscape Plan will be required in conjunction with the Final Site Plan.
Page 2 of 3
[Z.O. 32.5.2.(n), 32.6.2.(k), and 4.171: (Advisory only; no revision to Initial Site Plan is necessary) — An
approved Lighting Plan / Photometric Plan will be required in conjunction with the Final Site Plan. Staff
acknowledge Site Plan Note #6 on Sheet 4.
[Z.O. 32.7.4.2 and County Code Chapter 141: (Advisory only; no revision to Initial Site Plan is necessary) —
An easement plat would be required to establish the SWM Forest/Open Space Easement referenced in this Initial
Site Plan. Such an easement plat (with corresponding deed) would need to be submitted, reviewed, and approved
prior to County approval of the Final Site Plan.
Community Development Department — Engineering:
Contact: Matthew Wentland / mwentlandkalbemarle.org
Review Status: Requested Changes (8/2/2019) — see attached comment letter
Community Development Department — Inspections:
Contact: Michael Dellinger / mdellingerkalbemarle.org
Review Status: Requested Changes (7%31/2019) — see attached comment letter
Community Development Department — E911:
Contact: Andrew Slack / aslacWDalbemarle.org
Review Status: No Objection (7/9/2019) — see attached comment letter
Albemarle County Fire — Rescue:
Contact: Shawn Maddox / smaddoxkalbemarle.org
Review Status: Requested Changes (7/12/2019) — see attached comment letter
Virginia Department of Transportation (VDOT):
Contact: Adam Moore / Adam.Moorekvdot.vir ig nia.gov
Review Status: Requested Changes (7/18/2019) — see attached comment letter
Albemarle County Service Authority (ACSA):
Contact: Richard Nelson / rnelson(o)serviceauthority.org
Review Status: See Recommendations (8/6/2019) — see attached comment letter
Page 3 of 3
Review Comments for SDP201900041 11nitial Site Plan
Project Name: 1895 AON STREET EXTENDED - INITIAL
Date Completed: Friday, August 02, 2019 DepartmentlDivisionlAgency: Review sus:
Reviewer: Matthew Wentland 1 CDD Engineering Requested Changes
1 _ Please note the total area of disturbance to determine if a VMP plan is required_ If the existing gravel is to be paved and net }
regraded, it will be considered maintenance_
Page: County of Albemarle Printed On: 10810512019
Review Comments for SDP201900041 11nitial Site Plan
Project Name: 1895 AON STREET EXTENDED - INITIAL
Date Completed: Wednesday, July 31, 2019 DepartmentlDi+visionlAgency: Review Status:
Reviewer: Michael Dellinger _ 71 CDD Inspections1-1 1Requested Changes
Add the fallowing note to the general notes page:
Retaining walls greater than 3 feet in height require a separate building permit_ Walls exceeding 4 feet in height require a
stamped engineered design also_ Walls require inspections as outlined in the UBC_
Add the following note to the general notes page:
Accessible parking spaces and access isles shall not have a surface slope greater than 1:48_ Access isles shall be at the
same level as the parking space they serve_
Add the following note to the general notes page:
ALL water lines, sewer lines, and fire lines from the main to the structure MUST have a visual inspection performed by the
buildng department_
Add the following to the general notes page:
All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks_
Page: County of Albemarle Printed On: 10810512019
Review Comments for SDP201900041 11nitial Site Plan
Project Name: 1895 AON STREET EXTENDED - INITIAL
Date Completed: Tuesday, July 09, 2019 DepartmentlDi+visionlAgency: Review Status:
Reviewer: Andrew Slack CDD E911 No Objection
No objection_
Page: County of Albemarle Printed On: 10810512019
Review Comments for SDP201900041 11nitial Site Plan 0
Project Name: 1895 AON STREET EXTENDED - INITIAL
Date Completed: Friday, July 12, 2019 DepartmentlDi+visionlAgency: Review Status:
Reviewer: Lshawn Maddox Fire Rescue H Requested Changes
1 _ A knox box is required_ Please add a note indicating the requirement and that the location can be coordinated with the fire
marshal's
office-
_ Confirm the building height will be less than 30' to ensure the travel way is adequate-
3- The travel lanes in front of, and beside, the buildings shall be marked no parking fire lane to allow for apparatus turn around
on the site as opposed to backing out in to Avon Street Extended-
4- The new building is farther than 250' from the existing hydrant on Aeon Street_ A hydrant can be added to the site or on the
property side of Avon Street Extended_
Page: County of Albemarle Printed On: 10810512019
COMMONWEALTH of VIRGINIA
DEPARTMENT OF TRANSPORTATION
1601 Orange Road
Culpeper Virginia 22701
Stephanie C. Brich, P.E.
Commissioner
July 18, 2019
County of Albemarle
Department of Community Development
401 McIntire Road
Charlottesville, VA 22902
Attn: Tim Padalino
Re: SDP-2019-00041-1895 Avon St. Ext. Albemarle Lemo- Initial Site Plan
Dear Mr. Padalino:
The Department of Transportation, Charlottesville Residency Transportation and Land Use
Section has reviewed the 1895 Avon St. Ext. Albemarle Lemo - Initial Site Plan, dated June 24,
2019 as submitted by 30 Scale, LLC, and offer the following comment:
Land use
1. The current design of the proposed 4' sidewalk does not meet VDOT's minimum of 5
feet in width. A 4' buffer strip is also required. Please refer to VDOT's Road Design
Manual Appendix B(l), pg. 31, for design criteria.
Please note that the final site plan must show conformance with the VDOT Road Design
Manual Appendices B (1) and F, as well as any other applicable standards, regulations, or
other requirements.
A VDOT Land Use Permit will be required prior to any work within the right-of-way. The
owner/developer must contact the VDOT Charlottesville Residency Land Use Section at (434)
422-9399 for information pertaining to this process.
If you have further questions, please contact Willis C. Bedsaul at 434-422-9866.
SiiJncerel�',
Adam J. Mol, P.E.
Area Land Use Engineer
VDOT - Charlottesville Residency
VlrginiaDOT.org
WE KEEP VIRGINIA MOVING
Review Comments for SDP201900041 11nitial Site Plan
Project Name: 1896 A ON STREET EXTENDED - INITIAL
Date Completed: Tuesday, August 06, 2019 DepartmentlaivisionlAgency: Review Sys:
Reviewer: Richard Nelson AOSA See Recommendations
I recommend approval for SDP 01900041 - 1895 Avon Street Extended Initial Site Plan with the following conditions=
1_ Provide existing and proposed fixture counts_
Page: County of Albemarle Printed On: 10810612019