HomeMy WebLinkAboutSDP201900049 Review Comments Final Site Plan and Comps. 2019-09-17County of Albemarle Department of Community Development Memorandum To: Mitch Bowser, P.E. From: Cameron Langille — Senior Planner Division: Planning Services Date: September 17, 2019 Subject: SDP201900049 — Berkmar Drive Apartments — Final Site Plan The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approval of the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Applicable Comments from Initial Site Plan Action Letter (June 24, 2019): [4.16.1] A recreation substitution request was approved as part of the initial site plan with the condition that specific items of equipment proposed within the two outdoor tot lots, or "playgrounds" would be shown on the final site plan. The comment response letter from the applicant states that "the detailed design of the recreation areas and amenities is currently underway, and detailed plans reflecting the equipment shown in the previous exhibit will be provided prior to final site plan approval. " Please provide more details on the proposed tot lots/recreation areas. This includes construction details/cut-sheets for specific equipment items as outlined by the County Zoning Ordinance. The following facilities must be provided in the tot lots/playgrounds: a. [4.16.2.1] The recreation substitution request allowed for a total of 8,000 square feet of tot lot recreation area to be provided within two separate playgrounds ("Playground A" and "Playground B") in the project. Each tot lot must contain the following equipment: i. One (1) swing (four (4) seats); ii. One (1) slide; iii. Two (2) climbers; iv. One (1) buckabout or whirl; v. Two (2) benches. b. Calculations identifying the minimum recreation facilities required must be provided on the site plan. This includes the total quantity of tot lot equipment, the pool/deck area, outdoor gathering areas, fitness center, pond overlook and clubhouse that were approved with the recreation substitution request. c. The recreation areas must be shown on all applicable drawings and comply with the equipment and size standards specified in Section 4.16.1 of the Zoning Ordinance. d. Detail cut sheets for tot lot equipment must be provided in the construction details on the site plan e. [4.16.3] The following notes must be added to the site plan, including Sheet C0.0, the amenity plan (currently not included in plan set), and construction details sheet: i. "Recreational equipment and facilities shall be maintained in a safe condition and replaced as necessary. Maintenance shall be the responsibility of the property owner if rental units or a homeowners' association if sale units." ii. "Recreational facilities shall be completed when fifty (50) percent of the units have received certificates of occupancy." 2. [32.5.2 (a)] Please add a note to Sheet CO.0 stating the most recent instrument numbers (deed book and pages) for all recorded plats and deeds associated with parcels within the development. This includes the recorded instrument for the recently approved boundary line adjustment plat (SUB201800226). a. Sheets C2.0, 2.0, 3.0, and others still identify parcels A-D and the old TMP numbers, acreages, owners, and zoning districts. These drawings should be updated to reflect the revised TMP 32-54 that was recorded through the approved BLA plat (SUB201800226). b. Please be aware that the easement plat referenced in comment #18 below should also be referenced on the final site plan once it is recorded. 3. [32.5.2 (a)] Per the recorded BLA plat (SUB201800226), please provide labels across all applicable drawings that identify the R-15 and RA zoned portions of TMP 32-54. labels for all adjacent parcels shown on the plans. 4. [32.5.2 (a)] The existing cemetery location has been revised and shown on site plan and appears to be consistent with the cemetery location identified on the survey plat recorded in DB 5107 pages 617-620. Please be aware that the Code of Virginia, Section § 57-27.1 requires owners of private property on which graves or cemeteries are located to provide an access easement granting ingress and egress to certain parties wishing to visit the cemetery. Prior to final site plan approval, an access easement will need to be reviewed, approved, and recorded granting ingress and egress to the cemetery, in accordance with provisions of the Code of Virginia. Please visit the Code of Virginia using the following link for additional information: LINK. a. The private access easement can eb created with the easement plat referenced in comment #18 below. Once the easement plat is approved and recorded, all drawings in the site plan that label "Variable width private cemetery easement" will need to be revised so that the recorded instrument number for the plat and any associated deeds is referenced in the callout. [32.5.2 (a)] Please state the application numbers of all approved Special Use Permit and Zoning Map Amendments (ZMA) that apply to the development in Note 7 on Sheet CO.O.TMP 32-54 is subject to ZMA199200014 and SP 199500025. State these application numbers in Note 7. a. Please add all pages of the approved Action Letter from SP199500025 as an exhibit on Sheet CLO. Per applicant response, all applicable ZMA and SP application numbers will be referenced on the final site plan prior to approval. 6. [32.5.2 (a)] Please identify the minimum 5' side building setback line on Sheets C4.0-4.2 in accordance with comment #25 below. 7. [32.5.2 (b)] Please provide a table indicating the quantity of units proposed within each building. The table should include columns indicating how many units measuring less than 500 sq. ft., 1 bedroom, and 2 or more bedrooms are proposed within each building. Per applicant response letter, a table with the unit count will be provided with the final site plan. a. The total unit count by bedrooms should be specified so that staff can verify that adequate parking spaces are provided in accordance with the multifamily dwelling units parking requirements specified in Section 4.12.6 of the Zoning Ordinance. Per applicant response letter, a table with the unit count will be provided with the final site plan. Staff will verify that the parking provided complies with the Zoning Ordinance requirements at that time. 8. [32.5.2 (b)] In accordance with Section 18-4.12.13 (e), please show the dimensions for the dumpster pad and associated improvements on Sheet C4.2. Per applicant response, compacter and enclosure details will be provided as cut -sheets on subsequent submittal. 9. [4.12.19 and 32.7.9.7 (a)(3)] Please provide a profile view detail with dimensions and materials of the trash compactor enclosure to verify compliance with the screening requirements contained in the Zoning Ordinance. Please note that fences or other constructed screening measures must be a minimum of six feet (6') in height, as specified in 32.7.9.7 (e). Per applicant response, compacter and enclosure details will be provided as cut -sheets on subsequent submittal. 10. [32.5.2 (n) and 32.7.2.31 A sidewalk (and staircase if necessary) should be installed to provide access to buildings 3 and 4 from the four (4) parking spaces north of the structures. Additionally, a sidewalk (and staircase if necessary) should be installed to provide access from the 13 parking spaces north of building 2 to the sidewalk on the east side of building 2. 2 11. [32.7.2.31 There are four locations where ADA compliant striping is provided across within travel ways to connect handicap parking spaces to sidewalks on both sides of the travel way. In these four locations, only one side of the sidewalk has CG-12 ramps where sidewalks terminate at drive aisles. CG-12 ramps should be provided where sidewalks terminate at drive aisles on both sides. Locations are as follows: a. Sidewalk on east side of travel way between buildings 2 and 10. b. Sidewalk on east side of travel way between buildings 2 and 10. c. Sidewalk on south side of travel way north of building 3. d. Sidewalk on south side of travel way north of building 4. 12. [32.5.2 (n)] Please state the height of all proposed fences and retaining walls in the labels used on the drawings. Per applicant response, profile view/plan view construction details of all proposed fences, retaining walls, and constructed screening measures will be provided on a subsequent submittal showing materials and dimensions. a. See Engineering Division and Inspections Division comments for additional details on retaining wall requirements. 13. [4.7 (d)] All proposed open space areas that will be privately owned shall be subject to a legal instrument ensuring the maintenance and preservation of the open space that is approved by the agent and the county attorney in conjunction with the approval of the subdivision plat or site plan. Per applicant response, the instrument for privately owned open space will be submitted, reviewed, and approved prior to final site plan approval. a. Prior to final site plan approval, an easement or maintenance agreement must be resubmitted, reviewed, and approved by the County that demonstrates that private open space areas (including the tree save areas that will be used to earn the density bonus, and recreational open space areas) meet this requirement for maintenance and preservation. Per response noted above, the instrument ensuring maintenance of privately owned open space will be submitted during review of the final site plan. This can be accomplished through an subdivision easement application. 14. [32.5.2 (e)] Please provide more details about the existing landscape features as described in Section 18-32.7.9.4(c). a. The Albemarle County Conservation Plan Checklist and Chapter 3.38 of the Virginia Erosion and Sediment Control handbook. The Conservation Plan Checklist will need to be signed by the owners and provided as an exhibit on major amendment prior to approval. The checklist will need to be provided as an exhibit on the final site plan and signed by the owners. Some of the existing tree canopy on the north side of the development is being retained in order to satisfy minimum landscaping requirements of the Zoning Ordinance. b. [32.7.9.4 (c)] In both tree save areas, please identify the locations of all existing vegetation types that will be preserved. Use callout to identify the species of each vegetation type. Add a table to the Landscape Plans that identify the quantities, caliper, and height of all vegetation within these areas that will be saved. The landscape plan identifies existing wooded areas to be preserved, but specific information on types of vegetation, including species, quantity, caliper, height are not noted. c. The grading drawings and landscape plans should show the tree and vegetation protection measures that will be installed to protect existing vegetation from disturbance. The limits of disturbance should be labeled on both drawings and symbology should be added for the fences or other protection measures that will be installed. 15. [32.7.9.71 A double staggered row with 3 PIN TAE trees are shown at the southwest corner of the site. In order to meet the Ordinance screening requirements, shrubs and/or evergreen trees must be provided in the gaps between the three trees and the rest of buffer landscaping. The buffer should extend all the way south to the corner of the site. a. [32.7.9.7 (c) and 32.7.9.7 (d)] Update the Plant Schedule on Sheet L2.0 once the additional landscaping is added to Sheet L1.0 Update the individual canopy totals, quantity, and overall canopy provided columns/rows. b. Update the "Calculations" and "provided" columns of the Parking Screening Requirements table on Sheet L2.0 once the additional vegetation is added to the plans. 16. [32.7.9.81 Update the "Tree Cover Calculations" table on Sheet L2.0 so that the total canopy coverage provided on site reflects the added vegetation required in the previous comment. 17. [32.7.8 and 4.17] Please revise the lighting plan sheets as follows: a. [4.17.4 (a)] The luminaire schedule on Sheet L3.0 does not include a column stating the lumens emission for each luminaire type. This information must be provided so that staff can verify which luminaires must be full cutoff 3 fixtures. b. [4.17.4 (a)] Please provide documentation from the manufacturer that all proposed outdoor luminaries exceeding 3,000 lumens are full -cutoff fixtures. The cut -sheets on L3.1-3.4 are the entire manufacturer cut -sheets that do not clearly identify which options are being selected for the five luminaires proposed within the development. Staff cannot verify which, if any, luminaires will be equipped with full -cutoff fixtures. c. [4.17.4 (b)(2)] The manufacturer cut -sheets do not clearly verify that all luminaires will shielded to reflect light away from adjoining residential and rural area districts. This information must be provided for applicable luminaires. d. [4.17.4] The Calculations Summary table on Sheet L3.0 does not identify what maintenance factor has been used to calculate the footcandle measurements shown on the photometric plan. Albemarle County requires the maintenance factor must be 1.0 for photometric plans. Please provide this information on a subsequent submittal, and revise the photometric plan if footcandles exceed 0.5 at the property lines adjacent to residential or rural area zoning. e. The fixture symbols used in the Luminaire Schedule on Sheet L3.0 are identical for different luminaires types. Each luminaire should be identified by a unique symbol. Please revise. 18. [32.6.2 (d) and Chapter 141 Please submit an easement plat and application to the County that shows all new easements proposed by the site plan. This includes all new drainage, stormwater, public access easements, etc. The easement plat must be reviewed, approved, and recorded prior to approval of the final site plan. Per applicant response, an easement plat application will be submitted to the County for review, approval, and recordation prior to final site plan approval. 19. [General Comment] Prior to final site plan approval, a WPO plan must be submitted, reviewed, and approved by the Engineering Division. Please see Engineering comments below for additional information. 20. [General Comment] The Existing Conditions drawing identifies an "Existing 35' R/W per plat in DB 569, page 32" running across the site. The BLA plat (SUB201800226) vacated a segment of that feature. Please remove it from the existing conditions drawing, per the recorded plat. New Comments Final Site Plan: 21. [General Comment] On Sheet C4.3, the legend makes reference to an "Amenity Plan" for pavement/surfacing within the designated playground areas. However, an "Amenity Plan" sheet is not listed on the Index and staff cannot find any exhibits titled "Amenity Plan." Please advise. 22. [4.16.1] On all applicable sheets, please label the two playground areas as "Playground A" and "Playground B." 23. Please add the Site Review Committee signature panel (attached) to County Approval panel on Sheet C0.0. 24. [32.5.2 (a)] Under Note 16 on Sheet CO.0, state the minimum stepback requirements for the R-15 District height regulations, in accordance with Section 18.8 of the Zoning Ordinance: a. "Non-infill stepbacks - Front: For each story that begins above forty (40) feet in height or for each story above the third story, whichever is less, in height shall be 15 feet." 25. [32.5.2 (a)] The Zoning Ordinance was amended on July 17, 2019 and the minimum side setback requirements have changed for the R-15 Zoning District. Please make the following revisions: a. Under Note 23 on Sheet C0.0, please revise the minimum side setback requirement so that it states: "5 feet, unless the building shares a common wall; provided that (a) in the R-10 and R-15 districts if the abutting lot is zoned residential other than R-10 and R-15, Rural Areas, or the Monticello Historic district, any dwelling unit that exceeds 35 feet in height shall be set back 5 feet plus one foot for each foot the dwelling unit exceeds 35 feet in height; and (b) any minimum side setback otherwise required by this section may be reduced in accordance with section 4.11.3. " a. On Sheet C4.0-4.3, please show and label the 5' minimum side setback lines on the layout. 4 Please contact Cameron Langille at the Department of Community Development at blan ille =,albemarle.org or 296-5832 ext. 3432 for further information. Albemarle County Building Inspections — Michael Dellinger, mdellingergalbemarle.org - Requested changes, see attached. Albemarle County Engineering Services —David James, diames2@albemarle.org —Requested changes, see attached. Albemarle County E911 Services — Andy Slack, aslackkalbemarle.org Requested changes, see attached. Albemarle County Fire Rescue — Shawn Maddox — smaddoxkalbemarle.org — Fire Rescue review not yet complete, comments or approvals will be forwarded to the applicant upon receipt. Albemarle County Service Authority — Richard Nelson, rnelsongserviceauthority.org — ACSA review not yet complete, comments or approvals will be forwarded to the applicant upon receipt. Virginia Department of Transportation — Willis Bedsaul — wllis.bedsaul@vdot.virainia.gov — Requested changes, see attached. Review Comments for SDP201900049 IFinal Site Development Plan Project Name: Berkmar Drive Apartments - Final Date Completed: Thursday, August 29, 2019 DepartmentIDivisionfAgency: Review Sys: Reviewer: Michael Dellinger _ 71 CDD Inspections Requested Changes Add the following note to the general notes page: Retaining walls greater than 3 feet in height require a separate building permit_ Walls exceeding 4 feet in height require a stamped engineered design also_ Walls require inspections as oritlined in the UBC_ Add the following note to the general notes page: Accessible parking spaces and access isles shall not have a surface slope greater than 1:48_ Access isles shall be at the same level as the parking space they serve_ Add the following note to the general notes page: ALL water lines, sewer lines, and fire lines from the main to the structure MUST have a visual inspection performed by the building department_ Add the following to the general notes page: All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks_ Page: County of Albemarle Printed On: Fo91'1212 119 Berkmar Drive Apartments — Final SDP201900049 Engineering Comments (David James): 1. [John A., ISP comment] Obtain and furnish copy of wetland delineation coordination with the U.S. Army Corps of Engineers. Provide copy or evidence of permit coordination with the USACE for impacts to waters of the U.S., or wetlands, consistent with federal and state law. Response: Wetland delineation coordination is underway and will be provided prior to final site plan approval. Comment still valid. 2. Submit a VSMP application for review. The VSMP plan must be approved prior to FSP approval. 3. Remove sheets C3.0 — C3.4 (E&SC plan related). 4. Show any improvements outside of VDOT ROW in an easement (landscape, sidewalk, drainage, etc) and easements to be dedicated to the public. 5. Show any offsite work in an easement (outside of property line). A letter of permission from an off -site property owner will suffice for the purposes of plan review or record a plat. 6. Sheet 2.0/3.0: Verify drain inlet location near proposed entrance installation. 7. Ensure 100% capture at entrance so no site runoff flow runs out entrance into street travel lanes. [VDOT DM 9.4.5.2, 9.4.6.2] Will proposed entrance require culvert(s)? 8. Show accurate wall thickness & batter on the plan view sheets. 9. Show retaining wall locations and footer depth on the utility profile sheets. 10. Structural design plans will be required for walls over 4' high. 11. Show safety railing for walls over 30" high on the plans where next to vehicle or pedestrian travelways. [DSM, pg. 22] 12. Sheet 6.2: Tie in grading along roadway. 13. Grading — Constructed slopes steeper than 3:1 must be permanently stabilized with vegetation hardier than grass, which will not require mowing. Low maintenance is key. Highlight/Shade areas where required. [DSM, pg. 22] Links/refs: https://www.deg.virginia.gov/Portals/0/DEQ/Water/StormwaterManagement/Erosion Sediment C ontrol Hand book/Chapter%203%20-%203.32.pdf www.deg.virginia.gov/Portals/0/DEQ/Water/StormwaterManagement/Erosion Sediment Control Hand boo k/Chapter%203%20-%203.37.pdf Invasive Nan -Native Species Alternative Virginia Native Common Name Common Name Scientific Name Common Reed Great bulrush Scnoencp+ecluz tahernaemonlane Common Cattail TypHa latiloda Chinese Lespedeza Birdsfoot Trefoil Orchard Grass Redtop Weeping Lovegrass Roundheaded bushclover Lespedeza capilata Patrid a pea Chamaecrista lasciculata Butterflyweed Asdepras tuberosa Joe-pye weed Eutrachium duheum Black-eyed Susan Rudbeckia lulgida Big blue stem Andropogon gerardie Indian grass Sorghastrum nulans Side oats grama Souleloua cuRipendula Crownretch Roundheaded bushclover Lespedeza capitata Patridge pea Chamaecrisla lasoculala Big blue stem Andropogon gerardie Little blue stem ScPizachyrium scoparium Indian grass Sorghastrum oulans Switchgrass panicum vergalum Tall Fescue Big blue stem Andropogon gerardie Little blue stem ScHirachyrlum accpanum Indian grass Sorghastrum nulans Switchgram panicum mrgalum Broamsedge Andropogon virgmicus ❑eertongue Dichanlhe+ium clandestrnum Side oats grama Souleloua curhpendula Canadian vnldrye 0ymus canadensis Botllebrush grass Mymushyslrix Virginia wildrye 0ymus virgmicus 14. Sheet 4.0 - 4.2: a. Label/callout the inner parking lot curbing with VDOT designations. If no curb required, label the EOP. b. Label/callout CG-12. c. Label all sidewalk widths. d. Callout where any transitions occur. 15. Sheet 6.1/etc: a. Add drain inlet before curb bumpout and gutter along parking near buildings 1 & 3. b. Correct the grading near Mail Kiosk. The slope appears to exceed 2:1. [DSM, pg. 22] 16. Sheet 6.3/6.4: a. Show profile for pipes & structures shown on Sheet 6.2, Inset I-2. b. Show pipe runs: Storm 5 to 3, 3 to 1, 61 to 3. c. Show HGL, Label pipe crossing's separation distance, ensure 1' min. d. Provide 2.0' or % D minimum cover (whichever is greater). Ensure cover is adequate for pipes 6 - 12. 17. Sheet 6.5/etc: a. Access hole spacing is 50' (max) for 12" dia. pipe or less. b. Show tables for pipes & structures shown on Sheet 6.2, Inset 1-2. 18. Sheet 7.0/7.1: Label/show TOC line, LOD. 19. Sheet 7.2: Label/show catchment areas, TOC, Q for the inlet structures. Provide inlet design calcs. 20. Label ditches & channels. Provide design calcs. Show geometry and adequate lining information. 21. Show culverts are designed adequately (calcs). 22. Show storm drain pipes are designed adequately (calcs). 23. Show entrances with a VDOT designation (PE-1, CG-9a, etc). 24. Submit profile of the entrance road. Minimum K values of 5 for crest and 15 for sag should be met. 25. Show stationing & labels for the entrance road. 26. Label street name or designation. 27. Show street address sign at entrance & at opposite side from stop sign. 28. Show 10' wide (min) vehicle maintenance access to the SWM facility's forebay & riser structure. [DSM, pg. 12] 29. Provide estimate of cut/fill volumes for the entrance road & for the total site. 30. Note: There is some disagreement between the drawing and GIS where existing site features are shown. For example, the existing stream to the north and pond is shown inside the property line. On GIS it's outside. 31. Note: Stormwater management / Drainage design will be reviewed for local/state compliance with the VSMP plan. Review Comments for SDP201900049 Final Site Development Plan Project Name: Berkmar Drive Apartments - Final Date Completed: Thursday, August 22: 2019 DepartmentfDivisionfAgency: Review Status: Reviewer: Andrew Slack CDD E911 Requested Changes The applicant should contact this office with a list of three (3) proposed road names to this office for approval as a private read name for this development_ Please contact this office directly with any questions or the three (3) proposed road names_ Page: County of Albemarle Printed On: Fo91'12J20'19 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper Virginia 22701 Stephen C. Brich, P.E. Commissioner August 26, 2019 Cameron Langille County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SDP-2019-00049- Berkmar Drive Apartments — Final Site Plan Dear Mr. Langille: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Timmons Group, dated December 28, 2018, revised August 09, 2019, and offer the following comments. Please note the following comments 2 and 3 still remain applicable from the previous submission from April 2019. Land Use 1. The WP-2 standard requires mill and overlay of the adjacent travel lane. Please show these limits on the plans. 2. Please provide drainage calculations for proposed storm water structure tying into the Roadside ditch, pre and post construction for adequacy of discharge. Also please plot HGL on profile. The drainage information should be on the plan sheets. 3 Please provide trip generation data and turn lane warrant analysis. 4. CG-12 Ramps need to be perpendicular to each other for guidance into crosswalk. If further information is desired, please contact Willis C. Bedsaul at 434422-866. A VDOT Land Use Permit will be required prior to any work within the right of way. The owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, Adam J. Mole, P.E. Area Land Use Engineer Charlottesville Residency WE KEEP VIRGINIA MOVING