HomeMy WebLinkAboutAP201900004 Sewage Disposal System Minor Modification Design 2017-11-15Sewage Disposal System Minor Modification Design
THIS PLAN IS BEING SUBMITTED UNDER PROVISION 32.1-163.6 OF THE CODE OF VIRGINIA
AND DOES NOT POSE A GREATER RISK OF MALFUNCTION AS DEFINED IN THE SHDR 350 THAN CURRENT REGULATORY DESIGNS.
TM 50-49
7380 Gordonsville Rd A � a
Gordonsville, VA 22942
2.4 Acres
Burton, Evelyn & John R Maus
POBox E
Gordonsville, VA 22942
300 gallon per day system (2 BDR)
STE
New Sewage Ejector Station
Existing 1000 Gallon Septic Tank with effluent filter
Existing Drainfield
IAWW �P T OF ��
0
Page
M CHAEL CRAUN
Specifications 2 LICENSE No.
9
Site Plan 3 03685
\�o lr 5
Septic Tank Details 4 `ass0
Sewage Pump Details 5 ti�i40,AW�
M1
Old Dominion Engineering
2036 Forest Drive
Waynesboro, Va 22980
Phone: (540) 942-5600
email: olddomeng@ntelos.net
General
1. Modifications or substitutions to the specified equipment or layout must be approved by
the engineer.
2. The contractor should inspect the site prior to submitting an estimate to the owner. Any
potential conflicts should be reported to the engineer. By submitting an estimate the
contractor indicates that he has investigated the site and has found no discrepancies with
the plans and specifications.
3. A preconstruction conference is mandatory before starting installation of the
system. Contact engineer to discuss important aspects of installation. The engineer will
not certify the system at the final inspection unless a preconstruction conference is done
prior to installation.
4. A final inspection is required — The installation must pass inspection by the engineer.
Notify the engineer of the planned inspection date in advance. Prior to final inspection
the contractor should shoot all invert elevations and take as -built triangulation
measurements. The contractor shall provide as -built measurements to all components of
system to the engineer at the final inspection. The OWNER is responsible for paying the
engineer's inspection fees.
5. If adverse subsurface conditions are encountered (rock, groundwater, utilities, etc.)
contact the engineer.
6. If site conditions vary contact the engineer.
7. The contractor is responsible for maintaining all set back distances as required by local
ordinances and health department and payment for all inspections by health department.
8. Installation shall be in accordance with Virginia Department of Health Sewage Handling
and Disposal regulations and in accordance with erosion and sediment control guidelines.
9. A separate Project Manual contains calculations, equipment cut sheets, etc. A separate
package contains AOSE soil information.
10. Notify "MISS Utility" prior to excavation.
Gravity Sewer/Effluent Main/Force Main
1. Gravity sewer from the office to the sewage ejector tank is 4" SCH 40 PVC sewer.
Cleanouts every 50'.
2. Effluent mains shall be 4" schedule 40 PVC and have a slope of 6" per 100' minimum.
3. Force main and pressure piping shall be 2" Schedule 40 PVC.
L 1 H OF`�
� 2
o
M CHAEL F. CRAUN
LICEN E NO.
BONA i DA i
Septic Tank
1. Septic Tank - existing. Check tank to make sure it is not leaking and check tees for
alignment. The tank and all seams shall be waterproof •
2. The access port on the outlet end of the tank shall have a 24" waterproof riser. The riser
shall be attached to the tank and sealed.. Riser shall reach the surface and shall be
covered at the surface with lockable, watertight lids.
3. Zabel A300 12x20-VC-Ball effluent filter on tank.
Garage Sewage Ejector Tank
1. 24" diameter Polylok Basin with 24" Heavy Duty Lid. 50" min height. Basin to be
waterproof.
2. Pipe penetrations to be waterproof with Polylok grommets.
3. Inlet to tank shall be 4" SCH 40 PVC. Outlet is 2" SCH 40 PVC.
4. The risers shall extend 2" above final grade and shall be covered at the surface with a
plastic, lockable, watertight lid. The risers shall be 24" in diameter.
5. If rock is encountered in the tank hole then tank shall be bedded with 8" #68 stone. Tank
shall be backfilled in layers with sufficient compaction (> 95% compaction) to avoid
settling. Backfill material shall be free of debris and large stones. O
6. Tank shall be backfilled in layers with sufficient tamping to avoid settling. Backfill
material shall be free of debris and large stones. •
Sewage Ejector Pump •
1. Little Giant IOSN-CIA-RF (1/2 HP). Pump shall deliver 35 gpm @ 19 ft. Pump
operation is to be controlled by an integrated piggyback float. Hardwired electrical
connection in waterproof junction box.
2. Install 3/16 vent hole location before check valve per Little Giant recommendation O
Alarm Panel
1) Indoor/Outdoor Little Giant Alarm 303HWXT Alarm (513273). Alarm to be installed on
office. Alarm to be audiovisual and controlled by float. All electrical connections shall be
hardwired in a waterproof junction box.
12
Project Notes/Specifications
1317085
Notes:
1. Exact location of tanks will vary based upon topography and landscaping.
2. Provide Engineer with proposed as -built triangulation measurements at
preconstruction conference. /
3. Before pricing system installation, the contractor shall inspect the site and
verify dimensions, elevations, and layout of system.
4. Separation distance between building and septic tank, pump tank, header line or force main:
10' - when located below basement floor
20' - when located above basement floor
5. 5' separation distance between property line or easement from any septic or dripfield component
6. 15' separation to power lines.
7. 50' separation from lift station or farce main and well.
LAST 5' OF FORCE MAIN
IS 4" SCH 40 PVC.
ENTER MAIN SEWER
WITH 4" SCH 40 PVC WYE
EXISTING 1000 GALLON TOP SEAM SEPTIC TANK
NEW 24" RISER
NEW ZABEL A300 12X20-VC-BALL
DETAIL 4-1
CLEANOUT
I
I
EkISUNG
I DRAfNFIELD
1 \
4" SCH 40 PVC
2^ SCH 40 PVC
2BDR House
EXISTING
IIIC WELL
i
i
i
i
i
i
i
� O
GOAD
i
Izz
OFFICE
WM'I'rCHL'
H OF
11�
CD
F. CRAUN
LICENSE NO.
036859
1``—/CNA L Ar
SEWAGE EJECTOR
24" POLYLOK BASIN 50" HIGH (MIN)
LITTLE GIANT I OSN-CIA-RF PUMP
LITTLE GIANT HIGH WATER ALARM
DETAIL 5-1,2
4" SCH 40 PVC
CLEANOUT
Sewage Disposal
Site Plan
TM 50-49
7380 Gordonsville Rd
Gordonsville, VA 22942
Scale 1 — 50
O
M
Revision
1317085
HOUSE
AND —
OFFICE
HOUSE
AND -
OFFICE
i
HIGH PRESSURE SEAL',
(ASTM 1227) (ASTM 923
CONSEAL CS-102
(ASTM C-990)
USE SILICON ADHESIVE
BETWEEN RISER JOINTS
BRING TO JUST BELOW GRADE
OF EXISTING SLATE PATIO
WITH EZ SET POLY RISERS
SECTION VIEW
NOTES:
1. SEPTIC TANK IS EXISTING 1000 GALLON CONCRETE TANK
2. CHECK INLET - PER VDH SEWAGE DISPOSAL and HANDLING REGS
3. OUTLET WITH NEW EFFLUENT FILTER AND RISER
4. TANKS PENETRATIONS MUST BE WATERPROOFED AND NOT LEAK.
SEAL PIPE PENETRATIONS
5. 24" PLASTIC RISER ON OUTLET SIDE OF TANK.
D BOX
DRAINFIELD
5,000 PSI
REINFORCED
CONCRETE
SCREW DOWN RISERS WITH
STAINLESS STEEL SCREWS
/HIGH PRESSURE SEALS
" STM 1227) (ASTM 923)
D BOX
DRAINFIELD
ZABEL A300-12x20 VC -BALL
EFFLUENT FILTER
EXTEND HANDLE TO
UNDERSIDE OF RISER LID
1000 GALLON MID SEAM SEPTIC TANK
SECTION VIEW
Not To Scale
�� OTIH
�
o��
'
jAr
HAEL F. (CRAUN
LICENSE NO.
036859
/
�L E Ar
Septic Tanks Details
1!
1317085
BRING TO 2" ABOVE GRADE
POLY RISERS AND LID
24" HEAVY DUTY
POLYLOK RISER COVER
2" UNION AND 2" BALL VALVE
POLYLOK 24" DIAMETEI
POLYLOK WATER TIGHT GROMMET
OFFICE
High 1,
LITTLE GIANT IOSN-CIA-RF
SEWAGE PUMP
AUTOMATIC
NOTES:
1. SEWAGE EJECTOR PUMP TANK IS NEW 24" DIAMETER X 50" DEEP POLYLOK BASIN
2. INLET - 4" SCH 40 PVC, OUTLET - 2" SCH 40 PVC
3. TANKS PENETRATIONS MUST BE WATERPROOFED AND NOT LEAK; USE POLYLOK GROMMET.
4. 24" RISER ON TANK.
5. STRAP ALL PIPING TO TANK WITH PLASTIC STRAPS AND STAINLESS STEEL ANCHORS
6. FLOAT HEIGHTS WILL NEED TO BE ADJUSTED IF TANK DIMENSIONS VARY FROM 1.96 GAL PER INCH
7. EASY ACCESS TO VALVES AND UNIONS
24" SEWAGE EJECTOR PUMP TANK
OxeRGIOLIFAMATA
POLYLOK WATER TIGHT GROMMET
EXISTING
4" SEWER
TO
SEPTIC TANK
)sive lift rope
PUMP ON/OFF
Not To Scale
2
Polylok 24" Basin
One - 4" penetration (4" Polylok Grommet)
One - 2" penetration (2" Polylok Grommet)
One - V penetration (I" Polylok Grommet)
Water test prior to backfill
Pipe penetrations in designated spot
Connect segments per
Polylok Installation Instructions
REW DOWN RISERS WITH
TAINLESS STEEL SCREWS
24" POLYLOK BASIN
SECTION VIEW
PL OFF`
o
o �
MICHAEL F. CRAUN
LICENSE NO.
o� C 10318�9_
`S/CNA L \�
Not To Scale
Sewage Ejector Details
5
1317085