HomeMy WebLinkAboutAP201900004 Sewage Disposal System Minor Modification Design 2017-11-15Sewage Disposal System Minor Modification Design THIS PLAN IS BEING SUBMITTED UNDER PROVISION 32.1-163.6 OF THE CODE OF VIRGINIA AND DOES NOT POSE A GREATER RISK OF MALFUNCTION AS DEFINED IN THE SHDR 350 THAN CURRENT REGULATORY DESIGNS. TM 50-49 7380 Gordonsville Rd A � a Gordonsville, VA 22942 2.4 Acres Burton, Evelyn & John R Maus POBox E Gordonsville, VA 22942 300 gallon per day system (2 BDR) STE New Sewage Ejector Station Existing 1000 Gallon Septic Tank with effluent filter Existing Drainfield IAWW �P T OF �� 0 Page M CHAEL CRAUN Specifications 2 LICENSE No. 9 Site Plan 3 03685 \�o lr 5 Septic Tank Details 4 `ass0 Sewage Pump Details 5 ti�i40,AW� M1 Old Dominion Engineering 2036 Forest Drive Waynesboro, Va 22980 Phone: (540) 942-5600 email: olddomeng@ntelos.net General 1. Modifications or substitutions to the specified equipment or layout must be approved by the engineer. 2. The contractor should inspect the site prior to submitting an estimate to the owner. Any potential conflicts should be reported to the engineer. By submitting an estimate the contractor indicates that he has investigated the site and has found no discrepancies with the plans and specifications. 3. A preconstruction conference is mandatory before starting installation of the system. Contact engineer to discuss important aspects of installation. The engineer will not certify the system at the final inspection unless a preconstruction conference is done prior to installation. 4. A final inspection is required — The installation must pass inspection by the engineer. Notify the engineer of the planned inspection date in advance. Prior to final inspection the contractor should shoot all invert elevations and take as -built triangulation measurements. The contractor shall provide as -built measurements to all components of system to the engineer at the final inspection. The OWNER is responsible for paying the engineer's inspection fees. 5. If adverse subsurface conditions are encountered (rock, groundwater, utilities, etc.) contact the engineer. 6. If site conditions vary contact the engineer. 7. The contractor is responsible for maintaining all set back distances as required by local ordinances and health department and payment for all inspections by health department. 8. Installation shall be in accordance with Virginia Department of Health Sewage Handling and Disposal regulations and in accordance with erosion and sediment control guidelines. 9. A separate Project Manual contains calculations, equipment cut sheets, etc. A separate package contains AOSE soil information. 10. Notify "MISS Utility" prior to excavation. Gravity Sewer/Effluent Main/Force Main 1. Gravity sewer from the office to the sewage ejector tank is 4" SCH 40 PVC sewer. Cleanouts every 50'. 2. Effluent mains shall be 4" schedule 40 PVC and have a slope of 6" per 100' minimum. 3. Force main and pressure piping shall be 2" Schedule 40 PVC. L 1 H OF`� � 2 o M CHAEL F. CRAUN LICEN E NO. BONA i DA i Septic Tank 1. Septic Tank - existing. Check tank to make sure it is not leaking and check tees for alignment. The tank and all seams shall be waterproof • 2. The access port on the outlet end of the tank shall have a 24" waterproof riser. The riser shall be attached to the tank and sealed.. Riser shall reach the surface and shall be covered at the surface with lockable, watertight lids. 3. Zabel A300 12x20-VC-Ball effluent filter on tank. Garage Sewage Ejector Tank 1. 24" diameter Polylok Basin with 24" Heavy Duty Lid. 50" min height. Basin to be waterproof. 2. Pipe penetrations to be waterproof with Polylok grommets. 3. Inlet to tank shall be 4" SCH 40 PVC. Outlet is 2" SCH 40 PVC. 4. The risers shall extend 2" above final grade and shall be covered at the surface with a plastic, lockable, watertight lid. The risers shall be 24" in diameter. 5. If rock is encountered in the tank hole then tank shall be bedded with 8" #68 stone. Tank shall be backfilled in layers with sufficient compaction (> 95% compaction) to avoid settling. Backfill material shall be free of debris and large stones. O 6. Tank shall be backfilled in layers with sufficient tamping to avoid settling. Backfill material shall be free of debris and large stones. • Sewage Ejector Pump • 1. Little Giant IOSN-CIA-RF (1/2 HP). Pump shall deliver 35 gpm @ 19 ft. Pump operation is to be controlled by an integrated piggyback float. Hardwired electrical connection in waterproof junction box. 2. Install 3/16 vent hole location before check valve per Little Giant recommendation O Alarm Panel 1) Indoor/Outdoor Little Giant Alarm 303HWXT Alarm (513273). Alarm to be installed on office. Alarm to be audiovisual and controlled by float. All electrical connections shall be hardwired in a waterproof junction box. 12 Project Notes/Specifications 1317085 Notes: 1. Exact location of tanks will vary based upon topography and landscaping. 2. Provide Engineer with proposed as -built triangulation measurements at preconstruction conference. / 3. Before pricing system installation, the contractor shall inspect the site and verify dimensions, elevations, and layout of system. 4. Separation distance between building and septic tank, pump tank, header line or force main: 10' - when located below basement floor 20' - when located above basement floor 5. 5' separation distance between property line or easement from any septic or dripfield component 6. 15' separation to power lines. 7. 50' separation from lift station or farce main and well. LAST 5' OF FORCE MAIN IS 4" SCH 40 PVC. ENTER MAIN SEWER WITH 4" SCH 40 PVC WYE EXISTING 1000 GALLON TOP SEAM SEPTIC TANK NEW 24" RISER NEW ZABEL A300 12X20-VC-BALL DETAIL 4-1 CLEANOUT I I EkISUNG I DRAfNFIELD 1 \ 4" SCH 40 PVC 2^ SCH 40 PVC 2BDR House EXISTING IIIC WELL i i i i i i i � O GOAD i Izz OFFICE WM'I'rCHL' H OF 11� CD F. CRAUN LICENSE NO. 036859 1``—/CNA L Ar SEWAGE EJECTOR 24" POLYLOK BASIN 50" HIGH (MIN) LITTLE GIANT I OSN-CIA-RF PUMP LITTLE GIANT HIGH WATER ALARM DETAIL 5-1,2 4" SCH 40 PVC CLEANOUT Sewage Disposal Site Plan TM 50-49 7380 Gordonsville Rd Gordonsville, VA 22942 Scale 1 — 50 O M Revision 1317085 HOUSE AND — OFFICE HOUSE AND - OFFICE i HIGH PRESSURE SEAL', (ASTM 1227) (ASTM 923 CONSEAL CS-102 (ASTM C-990) USE SILICON ADHESIVE BETWEEN RISER JOINTS BRING TO JUST BELOW GRADE OF EXISTING SLATE PATIO WITH EZ SET POLY RISERS SECTION VIEW NOTES: 1. SEPTIC TANK IS EXISTING 1000 GALLON CONCRETE TANK 2. CHECK INLET - PER VDH SEWAGE DISPOSAL and HANDLING REGS 3. OUTLET WITH NEW EFFLUENT FILTER AND RISER 4. TANKS PENETRATIONS MUST BE WATERPROOFED AND NOT LEAK. SEAL PIPE PENETRATIONS 5. 24" PLASTIC RISER ON OUTLET SIDE OF TANK. D BOX DRAINFIELD 5,000 PSI REINFORCED CONCRETE SCREW DOWN RISERS WITH STAINLESS STEEL SCREWS /HIGH PRESSURE SEALS " STM 1227) (ASTM 923) D BOX DRAINFIELD ZABEL A300-12x20 VC -BALL EFFLUENT FILTER EXTEND HANDLE TO UNDERSIDE OF RISER LID 1000 GALLON MID SEAM SEPTIC TANK SECTION VIEW Not To Scale �� OTIH � o�� ' jAr HAEL F. (CRAUN LICENSE NO. 036859 / �L E Ar Septic Tanks Details 1! 1317085 BRING TO 2" ABOVE GRADE POLY RISERS AND LID 24" HEAVY DUTY POLYLOK RISER COVER 2" UNION AND 2" BALL VALVE POLYLOK 24" DIAMETEI POLYLOK WATER TIGHT GROMMET OFFICE High 1, LITTLE GIANT IOSN-CIA-RF SEWAGE PUMP AUTOMATIC NOTES: 1. SEWAGE EJECTOR PUMP TANK IS NEW 24" DIAMETER X 50" DEEP POLYLOK BASIN 2. INLET - 4" SCH 40 PVC, OUTLET - 2" SCH 40 PVC 3. TANKS PENETRATIONS MUST BE WATERPROOFED AND NOT LEAK; USE POLYLOK GROMMET. 4. 24" RISER ON TANK. 5. STRAP ALL PIPING TO TANK WITH PLASTIC STRAPS AND STAINLESS STEEL ANCHORS 6. FLOAT HEIGHTS WILL NEED TO BE ADJUSTED IF TANK DIMENSIONS VARY FROM 1.96 GAL PER INCH 7. EASY ACCESS TO VALVES AND UNIONS 24" SEWAGE EJECTOR PUMP TANK OxeRGIOLIFAMATA POLYLOK WATER TIGHT GROMMET EXISTING 4" SEWER TO SEPTIC TANK )sive lift rope PUMP ON/OFF Not To Scale 2 Polylok 24" Basin One - 4" penetration (4" Polylok Grommet) One - 2" penetration (2" Polylok Grommet) One - V penetration (I" Polylok Grommet) Water test prior to backfill Pipe penetrations in designated spot Connect segments per Polylok Installation Instructions REW DOWN RISERS WITH TAINLESS STEEL SCREWS 24" POLYLOK BASIN SECTION VIEW PL OFF` o o � MICHAEL F. CRAUN LICENSE NO. o� C 10318�9_ `S/CNA L \� Not To Scale Sewage Ejector Details 5 1317085