HomeMy WebLinkAboutSDP201900013 Review Comments Final Site Plan and Comps. 2019-09-24COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 Project: Wawa Pantops Corner — Final Site Plan Plan preparer: Ryan Perkins, Kimley-Horn Associates, 1700 Willow Lawn Drive, Suite 200 Richmond,VA 23230 [ryan.perkinsgkimley-horn.com ] Owner or Rep: Pantops Corner LC, 12704 Crimson Court, Suite 101; Henrico,VA 23233-7657 Applicant: Paul Sprouse, The Rebkee Company, 2800 Patterson Ave, Suite 200 Richmond, VA 23221 [psprousegrebkee.com] Plan received date: 6 Mar 2019 (Rev. 1) 29 Aug 2019 Date of comments: 23 Apr 2019 (Rev. 1) 24 Sep 2019 Reviewer: John Anderson Project Coordinator: Andy Reitelbach SDP2019-00013 (Comments below from ISP, SDP2018-00078) MEMO, 1. Provide 1" =2,000 (or less) scale vicinity map. (FSP) Addressed. 2. Include SDP201800078 in revised initial site plan title. (FSP) Addressed. As follow-up: With assignment of FSP file identifier, please revise next submittal to ref. SDP2019-00013. (Rev. 1) Addressed. 3. Engineering recommends include ZMA201300002 proffer on title sheet. (FSP) Addressed. 4. Ref. WP0201800088 (Pantops Corner VSMP Plan) as well as WP0201400028, Mass Grading and Erosion & Sediment Control Plan for Pantops Coiner, approved 6/11/14, with estimated area to be disturbed =7.01 Ac. (FSP) Addressed. 5. Note: Site under development does not have an existing stormwater management plan. A Mass Grading and ESC Plan was approved, 6/11/14. No development layout is shown with the Mass Grading and ESC Plan. Grandfathering (9VAC25-870-48) would not apply in this instance, for this reason. VAR IOE170 (VSMP Program VPDES) permit was issued for mass grading on 9/9/14. Grading has been performed, and site should be stabilized. If mass grade operations are complete, and site stabilized, it is time to terminate VAR10E170, and apply for a new VSMP permit for never - reviewed proposed development on this parcel. Further, VDEQ SWCGP database lists Construction Activity Operator (VAR 10E170) that does not match Initial Site Plan Owner information. Albemarle does not accept the position that this development is eligible for grandfathering, but views development subject to stormwater quality and quantity requirements at 9VAC25-870-65 and 9VAC25-870-66. (FSP) Review error. Comment withdrawn. CV- 101 (Existing Conditions) 6. Do not show: (FSP) Item 6 Addressed. a. Proposed development on TMP 78-58G1, which does not exist. b. Any proposed development features on TMP 78-5A, unless they exist. C. Show existing features only. If Applicant arranged with Planning Division to represent proposed features on CV-101 (Existing conditions), provide whatever elements were requested as an Exhibit or separate ISP sheet with appropriate title. Engineering Review Comments Page 2 of 7 7. Do show: (FSP) Item 7 Addressed. a. Full width of U.S. Rt. 250 where it fronts TMP #78-5A. Show existing travel lanes, turn lanes, traffic signs, median, etc. b. Steep slopes (Ref. County GIS Critical Resource layer). Managed steep slopes exist on this parcel. C. Proposed RW for private road Pantops Corner Way. (FSP) Addressed. Applicant response: `The proposed public access easement for the Pantops Corner Way is shown on Sheet CV-102 and CS- 101. There is no proposed right-of-way for this road.' 8. Add Note stating that all known existing easements are shown, or that none exist on TMP# 78-5A. (FSP) Addressed. 9. Provide Ownership information for parcel under development, and adjacent parcels: provide TMP#, owner name, DB/PG. (FSP) Addressed. CS- 101 (Site and Utilitv Plan 10. Transfer proposed development features from CV- 101 to CS- 101, including: a. For FSP approval (submit /respond to comments until approved): i. Retaining wall design, since proposed retaining walls support necessary infrastructure (engineered plans, not generic manufacturer's details). Consider county retaining wall plan review checklist. (FSP) Not addressed. See proposed plan view information, Final Site Plan checklist (Attached). Engineering restates requests for design to consider retaining wall plan review checklist. Specifically: 1. Provide complete retaining wall design specific to site design and site geotechnical parameters sealed by a geotechnical PE, for all walls that support infrastructure, roads, parking lots, drive aisles, or in close proximity to a property line. Final Site Plan checklist for reviewers states: `Retaining Wall Plans checklist. Any walls supporting roads or necessary infrastructure require engineered plans (not generic manufacturer's details) and computations. ,Design Manual, section 8} This will also be required where walls are close to property lines and there is the danger of affecting neighboring property, either during construction, with later failures, or with pedestrian or vehicle safety. These concerns can be alleviated with layout spacing also. In any case, retaining walls will require building permits at construction.' (Rev. 1) Addressed. 2. Delete reference labels that appear to transfer design responsibility to Pantops Corner Development. Engineering requires retaining wall design checklist items for retaining walls integral to Wawa site development. (Rev. 1) Addressed. 3. Provide private easements for retaining walls (Access /maintenance). (Rev. 1) Withdrawn. Plan review checklists (site /retaining wall) do not explicitly reference RW easements. Also, it is late to request retaining wall easements with Pantops Corner final plat (SUB201900059). Walls will be built with the Pantops Corner Development, not Wawa. 4. Label all six sets of retaining walls shown on plan sheet CV-102 (including a 2-tier wall, and a 3-tier wall). Label 1 - 6, or A - F. (Rev. 1) Addressed. 5. Only the 5' segmental block retaining wall is exempt from requirement to provide detailed, PE -sealed plan /profile design. (Rev. 1) Addressed. Retaining Wall Design: 5/28/19, Michael R. Circeo/PE. Ref. Laura Anderson, KHA, 8/22/19 email Attachment. WALL A v',:��,I. � A E N 5 W WALL B 1,F1-i-smnr not[i ` IS,lYl4iWT" l8180 _ '• �I I . 122 VIRgNL Engineering Review Comments Page 3 of 7 _ S 0 St.. 331, St 0_ _ ... WALL F s o _ WALL 6 �— WALL H i =.«�c • Sta. 237 �,.. 'St. 12WALL E 1 MA FLOW NI LL �11fI11Nllh%''_ l� DRAWING INDEX 5-1i r' = 100 FT SITE PLAN � Sheet o 50 00 1 Site Plan 2 General Notes/ Design Parameters Anchor Diamond Pro Segmental Retaining Walls 3-4 Details 5 Wall A - Ste. 0 to Ste. 184.5 Pantops Corner 6 Wall B - Ste. 0 to Stu. 187.5 7 Wall C - Ste. 0 to Stu.136 Albemarle County, Virginia 8 Wall D - Ste. 0 to Ste. 120 Site Plan Adapted From the Grading Plan, Sheet No. C6 of 19, Dated December 7, 2018 9 -10 Wall E - Ste. 0 to Ste. 237 11- 12 Wall F - Ste. 0 to Ste. 283.5 (Rev. 6 - 4/12/19), Prepared by Shimp Engineering, P.C. 13 - 14 Wall G - Ste. 0 to 5ta. 331.5 Site Plan For Illustrative Purpose. 15 - 16 Wall H - Stu. 0 to Stu. 366 Approx. Scale: I" = 100 FT Drainage plans. Consider county drainage plan review checklist, including: 1. Drainage structure typ. details. (FSP) Partially addressed. As ollow- Mp: Please include 2016 VDOT R&B Std. details (Site Details); including: (Rev. 1) Items a_e., addressed. a. Drop inlets, DI-1, DI-3B/C b. MH Safety steps, SS-1 C. Pipe bedding, PB-1 d. Inlet shaping, IS-1 e. Manhole, MH-1 Please also include commercial entrance detail: f. CG-11 (2016 R&B Standards) (Rev. 1) Not Addressed. Engineering Review Comments Page 4 of 7 2. Pipe and inlet type, length, diameter, material, slope, etc. (FSP) Addressed. 3. Calculations (LD-204, LD-229) a. Velocity /Capacity /Inlet spread and depth. (FSP) Partially Addressed. As,follow-uR: Provide LD-204 Inlet computations. (Rev. 1) Partially addressed. As follow-up: 8. V spread at LD-204 Table Str. ID 7 appears excessive since located at site entrance. Please lengthen throat opening, this structure. 4. Profiles, all elements labeled. (FSP) Addressed. As follow-up: In profile (CG-103), label Sir. B7 and A13 as BY OTHERS, since not existing. Also, Engineering recommends increase pipe slope from minimal acceptable 0.5% to 0.55%, for example. Often, designing to a minimum introduces issues during construction. This is a recommendation, not a requirement. (Rev. 1) Addressed. 5. Label inlets, pipes, and structures (FSP) Partially Addressed. As .follow-up: Please revise plan sheet CG-101 to Grading and Drainage Plan. (Rev. 1) Addressed. iii. Water and sewer line profiles. (FSP) Addressed. (Note: Water Line N/A) iv. WPO201800088, Pantops Corner, must be approved (prior to Wawa at Richmond Road and Stores Point Road FSP Approval). (FSP) Comment persists as noted, elsewhere. (Rev. 1) Addressed. WPO201800088 (Pantops Corner) was approved 7/23/19. V. Include Exhibit for o -site (TMP #78-58G1) SWM facilities required to meet stormwater quality and quantity requirements. (FSP) Not addressed; nor to be immediately addressed. Applicant (KI-IA) should coordinate with Pantops Corner LLC (hotel) design engineer (Shimp Engineering) to obtain at least conceptual stormwater management design information to address water quality and quantity requirements. At present, Wawa and Pantops Corner, LC (hotel) sites are owned by a single entity. That site plan application processes are pursued by distinct entities with Wawa site plan that includes direct /indirect reference to work to be performed by others (Pantops Corner LC), but there is a single owner (Pantops Corner, LC) at this time. The VSMP plan, WPO201800088, which amends WPO201400028, must be approved and bonded, with Wawa site properly registered with DEQ before SDP201900013 can be approved. Given current single ownership with sale pending to separate entity, this site plan should include an Exhibit consistent with WPO201800088 design at point of VSMP approval that ties SWM compliance requirements and compliance responsibility to the current owner of TMP #78-5A (Wawa site). Engineering recommends plan sheet images that capture salient specific SWM facility design information, titled SWM Exhibit Lor reference P!UN. Subtitled: Ref. WPO201800088 for approved VSMP plan. (Rev. 1) Addressed. Also, see item 33.b., below. vi. WPO201800088 must be bonded. (FSP) Comment persists. (Rev. 1) Comment may persist. Will confirm with Management Analyst if bond posted. vii. Pantops Corner Way must be (built or) bonded to limits required by Planning Division, as defined by ZMA201300002 proffer. (FSP /Rev. 1) Comment persists. Applicant response: `Comment noted.' (Rev. 1) Additional: Planning has no objection to road plan (comment d. 9/6/19). Engineering will coordinate with Planning to determine limits of road required to be bonded for FSP approval. 11. Note: Provide Road Plan under separate Application to County at earliest convenience. Ensure road plan design for Pantops Corner Way considers Road Plan checklist for plan reviewers, and includes a temporary turnaround meeting VDOT, Fire Rescue, and ACDSM needs, unless fiilly Engineering Review Comments Page 5 of 7 constructed between U.S. Rt. 250 and R. 20 with Wawa. Attached. (FSP) Addressed. SLB201900024 is under review. (Rev. 1) Comment persists. Nearly all Road Plan review comments addressed. 12. Light grayscale indicates Pantops Corner Way is existing. Revise to show Pantops Corner Way is proposed and is to be constructed with Wawa site plan to limits defined by Planning. Provide turnaround sufficient to meet multiple agencies temporary turnaround requirements. (FSP) Partially addressed. Applicant response: `The Pantops Corner Way is shown as proposed on Sheet CV- 101 and shaded as existing on Sheet CS-101 as it will be existing during the construction of the Wawa parcel.' Asfollow-tip: Label Pantops Corner Way `to be constructed BY OTHERS' on plan sheet CS- 101. (Rev. 1) Addressed. 13. Loading width is less than 12', if exclude area occupied by bollards. Revise to provide min. loading space width of 12'. (FSP) Addressed. 14. Delete note stating `Terraced Retaining Wall ...is to be designed and constructed as part of Pantops Corner Development plans.' The terraced retaining walls are intrinsic to site development. Include engineered PE -sealed retaining wall design plans with FSP. (FSP) Not addressed. Also, item 10.a.i., above. Comment persists. Applicant response: `Once available the retaining wall plans will be inserted into this plan set. It should be noted that the wall will be constructed by the current landowner as part of the Pantops Corner Way plans and not by Wawa. It is a condition in the purchase contract for this wall to be installed by the seller (current landowner).' Engineering welcomes this explanation. Please submit detailed PE -sealed design for 5 of 6 retaining wall locations shown on CV-102, if CV- 102 remains part of Wawa FSP. If CV-102 is removed from this FSP (as Engineering recommends), then provide detailed PE -sealed design for all retaining walls on TMP #78-5A prior to FSP approval. (Rev. 1) Addressed. Ref. 5/28/19 Circeo Design, sheets 7-8. Also, Applicant response (8/27/19): `As discussed, the retaining walls that are shown on the plans are all designed as part of the Pantops Corner Development Plans (SDP2018-00089) and are not proposed with the Wawa parcel development. Therefore, the call outs for the "retaining walls to be designed and constructed as part of Pantops Corner Development Plans" will remain on CS-101.' Engineering understands /accepts this position. 15. Provide VDOT GR-4- 2 (guardrail) for parking spaces fronting retaining wall; ensure sufficient parking space depth, once guardrail is installed. (FSP) Addressed. 16. Proposed SS line appears discontinuous. Revise to show connection with Ex. SS, or extend proposed SS to a logical endpoint. (FSP) Addressed. 17. If proposed retaining wall fronting Pantops Corner Way coincides with managed steep slopes, ensure design meets (retaining wall) design standards at 18-30.7.5. (FSP) Comment persists. Applicant response: `The wall plans will be submitted once available.' (Rev. 1) Addressed. Walls C, D, fronting Pantops Corner Way appear to meet 18-30.7.5 stds. Ref. 5/28/19 Circeo Design, sheets 7-8. 18. Likewise, storm drain pipe from DI at third southernmost parking space facing Pantops Corner Way is discontinuous. Clarify connection with downgradient elements of storm system. (FSP) Addressed. 19. Review proposed bike rack to ensure adequate clearance between typ. bike and proposed sidewalk (F-2' clearance, recommended). (FSP) Addressed. 20. Show proposed easements, including: a. Drainage (FSP) Partially addressed. As follow-up: Show drainage easements on CG- 101, since CG-101 is a Drainage and Grading plan. CS-100, titled boundary plan, shows drainage easements, and resembles a plat. Easements need to be shown with pipe /inlet structures (and SWM facility) if they are to be evaluated. (Rev. 1) Addressed. i. Ref. ACDSM, pg. 15 b. Sidewalk (FSP) Withdrawn. Sidewalks appear to be within public access easement. C. ACSA (FSP) Partially Addressed. CS-100 resembles a plat. Show ACSA easements on CS-101. Same rationale as above: Engineering cannot evaluate easements against invisible structures. (Rev. 1) Addressed. Engineering Review Comments Page 6 of 7 d. Sight (FSP) Addressed. e. RW (FSP) Addressed. Public Access Easement shown on CS-101. 21. Provide entrance sight lines, north -south, for vehicles exiting Wawa. (FSP) Addressed. 22. Label commercial entrance using VDOT nomenclature (CG-9a, etc.). (FSP) Addressed. 23. Label corner clearance distance from site entrance to U.S. Rt. 250. Engineering defers to VDOT. (FSP) Addressed. Note: Engineering defers to VDOT on corner clearance distance. 24. Label any spilling curb and gutter. (FSP) Addressed. 25. Label entrance curb radius. (FSP) Addressed. 26. Show trench drains. (FSP) Partially addressed. As oflow-up: South and East ends of trench are labeled with elevations, which is helpful. Please provide additional trench, oil -water separator elevations. Provide profile from the point where the two trenches join and a single pipe departs fuel 7. (Rev. 1) Partially addressed. As follow-up: Please confirm INV. IN /OUT for Stormceptor, which appears inconsistent with detail, sheet CG-501 FS FS 396.29 395.46 OIL +HATER TC FS SEPARATOR SEE STORMCEPTOR DETAIL INV. IN: 393.27 ON SHEET CG-501 INV. OUT: 383.15 CS-502 27. Provide concrete specification; provide 3000 psi strength at 28 days. (FSP) Addressed. 28. Provide dumpster pad detail. (FSP) Addressed. 29. Provide CG-6 detail. (FSP) Partially addressed. As follow-up: 6" depth of `spilling' gutter must match VDOT 0 '' 7" gutter depth. Revise CS-501 Spilling Curb and Gutter detail depth to 7". (Rev. 1) Addressed. CG-101 30. Recommend spot elevations at entrance. (FSP) Partially addressed. Engineering recormnends spot elevations at entrance EP. (Rev. 1) Addressed. 31. Ensure spills from filling UG fuel tanks reach trench drain. Check west -most UG tank, in particular. (FSP) Withdrawn. 32. Show steep slopes, this sheet. (FSP) Addressed. Shown on CG-101. 33. Stormwater Management Narrative (Also, items 5, 10.a.iv, above): (FSP) Not addressed. a. There is no evidence at this point that 2.4 5 lbs. of phosphor -us or -edits purchased from a nut-Fient bank will satisty stormwater manag mts. Delete specific reference to 2.45 lb. credit from site plan; instead, reference WPO201800088. Transfer specific, detailed SWM Narrative and design information to WPO201800088. (Rev. 1) Partially addressed. As follow-up: Remove CG-102 from Site Plan. SWM approved 8/16/19 w/ WPO201900026. b. Please note that WPO201800088 references 8.3 lb. purchase. WPO plan ,::... not been reviewed in detail; presentation and integration of TMP #78-5A and 78-58G1 SWM requirements into a single WPO requires care. (FSP) Comment persists. VSMP plan under review. (Rev. 1) Addressed. WPO201900026 Plan (Wawa at Pantops Corner) was approved 8/16/19. WPO201800088 (Pantops Corner) was approved 7/23/19. Note: Amendment to WPO201800088 is under review; this review does not affect WPO201900026 approval. CP-101 34. Provide note for vegetative ground cover hardier than grass for areas between discrete individual plantings north of retaining wall on north side of site (2:1 slope). Mulch may suffice. (FSP) Addressed. 35. Remove proposed street trees within drainage easement/s. Recommend show drainage easement/s on Landscape plan. (FSP) Addressed. 36. Street trees appear to obstruct sight distance. Provide sight lines. Also, item #21 above. (FSP) Addressed. New Engineering Review Comments Page 7 of 7 37. CV-102: It is unorthodox to include site information for separate parcel with separate site plan application under review with Albemarle County (SDP201800089). This separate site plan may be referenced, but detailed information shown with separate final site plan should not be included with SDP201900013 Final Site Plan (Wawa), as Wawa FSP approval would then in effect approve SDP201800089 site plan elements. Engineering defers to Planning. (Rev. 1) Comment persists. Applicant response: `It is understood that the final site plans will not be approved until SDP2018- 00089 plans [Pantops Corner Final Site plan] have been approved.' 38. Note /Reminder: All roadway (Pantops Corner Way /U.S. Rt. 250 /SR 20) elements shown with FSP201900013 must be consistent with Road Plan design at point Road Plan is approved (SUB201900024). In other words, Road Plan approval is required prior to FSP approval. (Rev. 1) Comment persists. Applicant response: `It is understood that the final site plans will not be approved until Road plans FSP2019-00013 [SUB2019-00024] have been approved. 39. CS- 101 /Site Legend: There is no concrete sidewalk detail on CS-501. Please provide concrete sidewalk detail or revise title of Mountable curb/island and stamped concrete detail (CS-502), if this detail may serve two purposes (stamped /plain). (Rev. 1) Addressed. CS-101 40. Label sidewalk along U.S. Rt. 250 `by others.' (Rev. 1) Addressed. 41. Label sidewalk along Pantops Corner Way `by others.' (Rev. 1) Addressed. 42. Provide bumper blocks for all 18' L parking spaces adjacent to GR-2. (Rev. 1) Withdrawn. Applicant response: `Wheel stops are not proposed adjacent to the retaining wall and GR-2 as Wawa does not allow them on their sites due to safety/tripping hazards.' Although withdrawn, Engineering recommends wheel stops as an additional safety measure for parking spaces adjacent to GR-2. There is slight likelihood pedestrians exiting vehicles will walk in direction of either GR-2 or retaining walls. 43. Provide /show detectable surface at ramp on west side of stamped asphalt crosswalk. (Rev. 1) Addressed. Please call if any questions: 434.296-5832 —x3069 Thank you SDP201900013 Wawa Pantops_FSP_092419rev1