Loading...
HomeMy WebLinkAboutARB201900105 Plan - Revision 2019-09-25Branding Package Store 17626 314 Rolkin Rd. Charlottesville, VA 22911 Standard c1ma building brands together Channel Letters 65.0 It • Channel Letters 74.8 • EXIST 1.4a / 120v 138 Ibs - Pharmacy 7.4 Y 0.7a / 120v 18 Ibs Verify primary power Aggregate Allowed SF 180 TSFI 65.0 TSFI 82.2 Channel Letters 65.0 •' • Channel Letters 74.8 EXIST 1.4a / 120v 138 Ibs - Pharmacy 7.4 y 0.7a / 120v 18 Ibs Verify primary power TSFI 65.0 Aggregate Allowed SF 180 TSFI 82.2 tters 9.0rFCO 8 Existng 1.4a/120v 40 Ibs 17- 4.0 Aggregate Allowed SF 180 2.99 Repair Canopy ign N/APlaque 1.67 1 TSFI 16.2g TSFI Monument) Sign 27.3 Monument Reface 27.3 - New Retainer Required Directional Sign N/A Leave As -Is N/A Directional Sign N/A Remove N/A Total 27.3 Allowed SF 32 JOstad27.3 ZONING CLASSIFICATION Cl TOTAL ALLOWED SO FT: Freestanding: 32 Total 16 Each Building: 100 Total ACCOUNT SPECIFIC CODE CONSIDERATIONS FREESTANDING per street frontage, or 2 per entrance, per lot with 100 or more feet of continuous street frontage plus 1 per lot if the lot is greater than 4 acres & has more than 1 approved entrance on it's frontage. 32 square feet, plus bonus tenant panels; if more than 1 sign at an entrance, no single sign shall exceed 16 square feet In the C-1 and HC districts. Max overall height:12 feet. WALL SIGNS 1.5 square feet per 1 linear foot of establishment structure frontage, not to exceed 100 square feet WINDOW SIGNS N/A BANNERS & TEMP SIGNS 1 per street frontage per establishment. Max 32 SF. 12 feet, if freestanding sign; 20 feet, if residential wall sign; 30 feet if nonresidential wall sign, but not to exceed the cornice line. Zoning Officer/ Code Enforcement Bart 434-296-5832 Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibited in anyfashion without the expressed constentofCima Network, Inc. SYMBOLS DESCRIPTION: BYCIMA BYGC ,Ze 120 Volt Junction Box W Elect Whip: 1/2"0 x U-0" Lg Greenfield LED Power Supply �B� Blocking Req'd II Additional Structure Req'd. p Special Condition Applies ® Access Panel - Field Cut Additional Information Req'd. © Remove Remain As -Is © Relocate REV# DATE REVISIONS REVISION NOTES: BY SHEET 1 1-31-19 Removed the linkopldrepofrsign EMA 2,8 2 4-15-19 RemovedPhernacyfoin Up on3slevadans,revlsedmanonenttaglling LAW ALL 3 4-18-19 Added Cleaara Plaque EMA 4 8 2019 Fah designs KG ALL 5 82219 loll pylon face to opaque while, KG 17 6 917 19 PERMIT DESIGN Total aggregate sol allowed is 180 remove sign 3 and 4 decrease Sign 2 and 6 to WAG-PI2R-R EMA 2,4-8 7 9.24.19 o,e �w��ea.,�,Demo.s,ilisIs-Igoo,.11,n1Paa.a..w,,saae.�w ,e,eaemae41,11e.,�an�o1e�;, eo„i,,a11aftNii ..�,we.Pe,wdo o ��agessxa„e ay Ne.aa,a„,,.n.sev,aad�a.,oesa,� es�.,aawaa.nres�.aeaua„oesrsa�os,,..mo<yeweemo,,romw.�merdNm.,mYon,aea.,aa„ EMA ALL All Electric Signs to be manufactured to meet the requirements of Client: Walgreens Ul48 and installed to meetthe requirements of Article 600 ofthe q Dwg By: CMC National Electrical Code and/or other applicable local codes. This includes proper grounding and of thesi n. Date: 1.24.19 P P 9 9 9 9 I Job#: 7405 Store* 71626 Address: 314 Rolkin Rd. r Charlottesville, VA 22911 W BUILDING ELEVATIONS DRIVE THRU c1ma %k DRIVE THRU CANOPY DAMAGE Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibited in arryfashion without the expressed constentofCima Network, Inc. DAMAGED DIRECTIONAL lir r.Wow- 4 11 �,. �:li h FASCIA DAMAGE & DISCOLORATION All Electric Signs to be manufactured to meetthe requirements of Client: Walgreens UI 48 and installed to meetthe requirements of Article 600 of the Dwg By: CMC National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding ofthesign. I Date: 1.24.19 Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT Of 19 3 c1ma k EXISTING PROPOSED Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is itto be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibitedinanyfashionwithouttheexpressed constentofCimaNetwork, Inc. FRONT•ELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE • • EXISTING: 65.0 SO FT PROPOSED: 82.2 SO FT ALLOWED: 100.0 SO FT Total For Building -----------------------, --------------------- 1 - I I 1 I 1 ' I I - - - - - - - I I I 1 1 I IL-------------------' I L----------------------- i CENTER SIGN IN AVAILABLE AREA I I L ------------ I -------------- I CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meet the requirements of Client: Walgreens q UI 48 and installed to meet the requirements of Article 600 of the PP National Electrical Code and/or other applicable local codes. Dwg By: CIVIC This includes proper grounding and ofthe n. Date: 1.24.19 P P 9 9 9 9 I Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT of 16 4 c1ma k EXISTING PROPOSED Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any fashion without the expressed constant of Cima Network, Inc. FRONT•ELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE •• EXISTING: 65.0 SO FT PROPOSED: 82.2 SO FT ALLOWED: 180 SO FT Total For Building It -------------------------1 WINN"MW I I I I I I I L--------- -----' I L----------------------- J CENTER SIGN IN AVAILABLE AREA I I L ------------ I -------------- I CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of }hest n. Date: 1.24.19 P P 9 9 9 9 I Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT Of 19 5 EXISTING PROPOSED This is an original, un unpublished drawing, created b Cima Network Inc. It is submitted for Cima Network Inc. office: 267.308.0575P g, y 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a projectbeing proposed by Cima Network, Inc. iris notto be shown to anyone outside your organization, nor is itto be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibited in arryfashion without the expressed constentofCima Network, Inc. All Electric Signs to be manufactured to meet the requirements of Client: Walgreens q Ul48 and installed to meetthe requirements of Article 600 ofthe National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of thesi n. Date: 1.24.19 P P 9 9 9 9 I FRONT•ELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE •• EXISTING: 65.0 SQ FT PROPOSED: 00.0 SQ FT ALLOWED: 180 SQ FT Total For Building Job#: 7405 Store* 71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT of 19 6 c1ma k 18'-41 /8" aa]oft 18' 4-1/4" CHANNEL LETTERS \7J SCALE: 3/8" = V 0" (2) REQ'D nCA Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any fashion without the expressed constant of Cima Network, Inc. 5" --——————————'——————— — — — — —I I Of r I I I I IKL I L— — — — — ——----——— — — — — —— I I------------------------ SIDE VIEW CENTER SIGN IN AVAILABLE AREA 7 SCALE: 3/8" = 1' 0" DETAIL @ ANGLE CLIP �7J SCALE: HALF SIZE COLORS & FINISHES PF1.EFACE: #2793 Red Acrylic Face PF2.ERETURNS: Pre -finished Hunter Red PF3.ETRIM CAP: Pre -finished True Red SIGN CONSTRUCTION 1. RETURNS: 040" Pre -finished Aluminum Returns Stapled/Pop Riveted To Backs 2. TRIM CAP: 1" Wide w/ #8 X 1/2" Long Pan Head Screws Painted To Match 3. FACES:.177" Thick #2793 Red Acrylic. 4. BACKS:.063 Thick Routed Aluminum 5. DRAIN HOLES: (3) 1/4"0 Per Letter. One Must Be As Close To Back As Possible ELECTRICAL (SIGN TO BE UL LISTED) 6. LEOS: Sloan Prism Red 7. WIRE: Secondary Low Voltage Led Wire 8. PASS THRU: Paige Wallbuster Or Approved Equal. 9. POWER SUPPLY: Sloan 60C1 60 Watt 12VDC Class 2 Power Supply Inside Enclosure. 10. ENCLOSURE: Paige Box Or Approved Equal 11. PRIMARY: 1/2" Conduit To Disconnect Switch Secure To Wall w/Straps By Others 12. SERVICE SWITCH: Located On End Of Enclosure INSTALLATION HARDWARE Threaded Rod Will Be Provided Standard. All Other Hardware Is to Be Provided By Installer As Required. 13. RIV-NUTS: 1/4-20. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 14. ANGLE CLIPS: 1/8" x 1-1/2" x 1-1/2" Aluminum. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 15. HARDWARE: Min. 1/4"0 Non -corrosive Hardware. (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Sections BUILDING & FASCIA CONDITIONS 16. WALL SURFACE: Varies CHANNEL LETTER INSTALLATION NOTES: 1. Sufficient Primary Dedicated Circuit Within 5' Of Center Of Sign By Others. 2. Final Primary Hook-up By Sign Installer Where Allowed By Local Codes. 3. All Visible Wiring & Conduit To Be Run In Straight Lines & 90' Bends. 4. Seal All Building Penetrations. 5. Mounting Hardware By Sign Installer Unless Otherwise Noted. TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITIO SIZE, LOCATION AND QTY NOTED ON DWG SEAL ALL BUILDING PENETRATIONS THRU BOLT RIV-NUTS WITH ALL -THREAD. UNI-STRUT OR 1-112" X 1-1/2" X 1/8" ALUM ANGLE SLEEPERS SPANNING MIN (2) STRUCTURAL WALL MEMBER; ANTI -CRUSH SPACERS AS REO'D FOR LAG BOLT LAG BOLT INTO MIN 3/4" PLYWOOD. (THREADS MUST PASS THRU PLYWOOD). ANTI -CRUSH SPACERS AS REO'D FOR EIFS OR HOLLOW FASCIA EXPANSION ANCHOR EXPANSION ANCHOR INTO SOLID CONCRETE OR GROUT FILLED MASONRY 1-1/4" MIN EMBEDMENT (NOT FOR HOLLOW MASONRY) **ALL HARDWARE MUST BE NON -CORROSIVE** All Electric Signs to be manufactured to meet the requirements of Client: Walgreens q UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of }hest n. Date: 1.24.19 P P 9 9 9 9 I EST. ELECTRICAL LOAD (1.4) Amps @120 Volts ELECTRICAL REQUIREMENTS (1) 20 Amp/120 Volt Circuits ESTIMATED WEIGHT 1 138 lbs. Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT Of 19 7 7'-4 3/4" LPHARM__ __ACY _... c1ma A ®Oft 12" CHANNEL LETTERS;♦ �8J SCALE:1/2" = 1' 0" (2) REQ'D eDETAIL @ PHARMACY 8 SCALE: 1-1/2" = V o" SIDE VIEW 8 SCALE: 3/8" = 1' o" Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any fashion without the expressed constent of Cima Network, Inc. -------------------------, I � _ I I A I — -1--I L-------- I CENTER SIGN IN AVAILABLE AREA TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITIO SIZE, LOCATION AND QTY NOTED ON DWG SEAL ALL BUILDING PENETRATIONS THRU BOLT RIV-NUTS WITH ALL -THREAD. UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8" ALUM ANGLE SLEEPERS SPANNING MIN (2) STRUCTURAL WALL MEMBER ANTI -CRUSH SPACERS AS REQ'D FOR LAG BOLT LAG BOLT INTO MIN 3/4" PLYWOOD. (THREADS MUST PASS THRU PLYWOOD). ANTI -CRUSH SPACERS AS REO'D FOR EIFS OR HOLLOW FASCIA EXPANSION ANCHOR EXPANSION ANCHOR INTO SOLID CONCRETE OR GROUT FILLED MASONRY. 1-1/4" MIN EMBEDMENT (NOT FOR HOLLOW MASONRY) **ALL HARDWARE MUST BE NON -CORROSIVE** All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the q National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of }hest n. Date: 1.24.19 P P 9 9 9 9 I COLORS & FINISHES PF1.0FACE: #2793 Red Acrylic Face PF2. 0 RETURNS: Pre -finished Hunter Red PF3.0TRIM CAP: Pre -finished True Red SIGN CONSTRUCTION 1. RETURNS: 040" Pre -finished Aluminum Returns Stapled/Pop Riveted To Backs 2. TRIM CAP: 1 " Wide w/ #8 X 112" Long Pan Head Screws Painted To Match 3. FACES:.177" Thick #2793 Red Acrylic. 4. BACKS:.063 Thick Routed Aluminum 5. DRAIN HOLES: (3) 1/4"0 Per Letter. One Must Be As Close To Back As Possible ELECTRICAL (SIGN TO BE UL LISTED) 6. LEDS: Sloan Prism Red 7. WIRE: Secondary Low Voltage Led Wire 8. PASS THRU: Paige Wallbuster Or Approved Equal. 9. POWER SUPPLY: Sloan 60C1 60 Watt 12VDC Class 2 Power Supply Inside Enclosure. 10. ENCLOSURE: Transformer Box By Installer 11. PRIMARY: 1/2" Conduit To Disconnect Switch Secure To Wall w/Straps By Others 12. SERVICE SWITCH: Located On Enclosure INSTALLATION HARDWARE Threaded Rod Will Be Provided Standard. All Other Hardware Is to Be Provided By Installer As Required. 13. RIV-NUTS: 1/4-20. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 14. ANGLE CLIPS: 1/8" x 1-1/2" x 1-1/2" Aluminum. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 15. HARDWARE: Min. 1/4"0 Non -corrosive Hardware. (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Sections BUILDING & FASCIA CONDITIONS 16. WALL SURFACE: Varies CHANNEL LETTER INSTALLATION NOTES: 1. Sufficient Primary Dedicated Circuit Within 5' Of Center Of Sign By Others. 2. Final Primary Hook-up By Sign Installer Where Allowed By Local Codes. 3. All Visible Wiring & Conduit To Be Run In Straight Lines & 90' Bends. 4. Seal All Building Penetrations. 5. Mounting Hardware By Sign Installer Unless Otherwise Noted. Design approval RFI number (#2069) EST. ELECTRICAL LOAD (2.0) Amps @120 Volts ELECTRICAL REQUIREMENTS (1) 20 Amp/120 Volt Circuits ESTIMATED WEIGHT 50 lbs. Job#: 7405 Store* 71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT of 19 8 c1ma k EXISTING PROPOSED Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any fashion without the expressed constant of Cima Network, Inc. REAR •RELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE • • EXISTING: 9.0 SQ FT PROPOSED: 9.7 SQ FT ALLOWED: 100.0 SQ FT Total For Building -----------------------, ----DRIVETHR---- L----------------------- i CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of }hest n. Date: 1.24.19 P P 9 9 9 9 I Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT Of 19 9 c1ma A DRIVE THRU ®0 12" DRIVE THRU CHANNEL LETTERS 10 SCALE: 3/4" = 1' 0" (1) REQ'D PF2 PF3 PF1 1 SCALE `i-1/2" = 1' 0" Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any fashion without the expressed constent of Cima Network, Inc. 5" SIDE VIEW 10 SCALE: 3/4" = 1' 0" i ----------;----------I I I - - --DRIVETHR-U- - I I L----- ---- 7----------I I L-----------------------� CENTER SIGN IN AVAILABLE AREA COLORS & FINISHES PF1.FACE: #2793 Red Acrylic Face PF2.RETURNS: (PB) Pre -finished Hunter Red PF3.TRIM CAP: (PB) Pre -finished True Red SIGN CONSTRUCTION 1. RETURNS: 040" Pre -finished Aluminum Returns Stapled To Backs 2. TRIM CAP: 1 " Wide w/ #8 X 112" Long Pan Head Screws Painted To Match 3. FACES:.177" Thick #2793 Red Acrylic. 4. BACKS: 3mm Thick Routed ACM Stapled To Returns 5. DRAIN HOLES: (3) 1/4"0 Per Letter. One Must Be As Close To Back As Possible ELECTRICAL (SIGN TO BE UL LISTED) 6. LEDS: Sloan Prism Red 7. WIRE: Secondary Low Voltage Led Wire 8. PASS THRU: Paige Wallbuster Or Approved Equal. 9. POWER SUPPLY: Class 2 Power Supply Inside Enclosure. 10. ENCLOSURE: Transformer Box By Installer 11. PRIMARY: 1/2" Conduit To Disconnect Switch Secure To Wall w/Straps By Others 12. SERVICE SWITCH: Located In Junction Box By Others INSTALLATION HARDWARE Threaded Rod Will Be Provided Standard. All Other Hardware Is to Be Provided By Installer As Required. 13. RIV-NUTS: 1/4-20. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 14. ANGLE CLIPS: 1/8" x 1-1/2" x 1-1/2" Aluminum. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 15. HARDWARE: Min. 1/4"0 Non -corrosive Hardware. (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Sections BUILDING & FASCIA CONDITIONS 17. WALL SURFACE: Varies CHANNEL LETTER INSTALLATION NOTES: 1. Sufficient Primary Dedicated Circuit Within 5' Of Center Of Sign By Others. 2. Final Primary Hook-up By Sign Installer Where Allowed By Local Codes. 3. All Visible Wiring & Conduit To Be Run In Straight Lines & 90' Bends. 4. Seal All Building Penetrations. 5. Mounting Hardware By Sign Installer Unless Otherwise Noted. TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITIO SIZE, LOCATION AND QTY NOTED ON DWG SEAL ALL BUILDING PENETRATIONS THRU BOLT Ic RIV-NUTS WITH ALL -THREAD. UNI-STRUT OR 1-112" X 1-1/2" X 1/8" ALUM ANGLE SLEEPERS SPANNING MIN (2) STRUCTURAL WALL MEMBER; ANTI -CRUSH SPACERS AS REO'D FOR LAG BOLT uP­ LAG BOLT INTO MIN 3/4" PLYWOOD. (THREADS MUST PASS THRU PLYWOOD). ANTI -CRUSH SPACERS AS REO'D FOR EIFS OR HOLLOW FASCIA EXPANSION ANCHOR EXPANSION ANCHOR INTO SOLID CONCRETE OR GROUT FILLED MASONRY 1-1/4" MIN EMBEDMENT (NOT FOR HOLLOW MASONRY) **ALL HARDWARE MUST BE NON -CORROSIVE** All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the q National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of }hest n. Date: 1.24.19 P P 9 9 9 9 I EST. ELECTRICAL LOAD (2.0) Amps 9120 Volts ELECTRICAL REQUIREMENTS (1) 20 Amp/120 Volt Circuits ESTIMATED WEIGHT 1 50 lbs. Job#: 7405 Store* 71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT of 19 10 01i n k r, EXISTING PROPOSED Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibited in arryfashion without the expressed constentofCima Network, Inc. REAR (NORTHEAST) ELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE • • EXISTING: 9.0 SQ FT PROPOSED: 9.7 SQ FT ALLOWED: 100.0 SQ FT Total For Building i I I - --@--4"-$t RANGE- - - - I I I i I L-----------'------------ CENTER SIGN IN AVAILABLE AREA REV I.24.19 7 All Electric Signs to be manufactured to meet the requirements of Client: Walgreens Job#: 7405 Store#: 71626 Ul48 and installed to meetthe requirements of Article 600 ofthe National Electrical Code and/or other applicable local codes. Dwg By: CMC Address: 314 Rolkin Rd. This includes proper grounding and bonding ofthesign. I Date: 1.24.19 Charlottesville, VA 22911 Mi c1ma k 12" 4'-0" 2'-0" 8'-0" CLEARANCE eCLEARANCE PLAQUE 12 SCALE: 1-1/2" = 1' 0" (1) REQ'D I I I i --——— — — — --- ------------ CENTER SIGN IN AVAILABLE AREA 6 O2 4 V2 1 O V1 V2 © DETAIL -WALL MOUNT �J SCALE: 1-1/2" = 1' 0" Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any fashion without the expressed constant of Cima Network, Inc. 12" O 1" From Back Of Sign © DETAIL - HANGING MOUNT �1J SCALE: 1-1/2" = IT' All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of }hest n. Date: 1.24.19 P P 9 9 9 9 I DESCRIPTION Exterior Canopy Clearance Plaque. Sign To Be Fabricated As Wall Or Hanging Mount. COLORS & FINISHES V1.❑ VINYL: 1 st Surface 3M 580-71 Reflective Yellow V2.0 VINYL: 1 st Surface 3M 3630-22 Black P1.❑ PAINT: Edges To Match 3M 580-71 Reflective Yellow SIGN CONSTRUCTION 1. SIGN PANEL: 1/8" Flat Aluminum w/ 1st Surface Vinyl & Edges Painted To Match Vinyl. 2. HOLES: (4) 3/16"0 - (1) In Each Corner For Wall Mount Hardware 3. HOLES: (2) 1/4"0 In Top For Hanging Hardware INSTALLATION HARDWARE 4. HARDWARE: Minimum #10 Non -Corrosive Hardware To Suit Wall Conditions. Min. (4) Per Sign Panel 5. HARDWARE: (2) 3/16"0 Non -Corrosive "S" Hooks For Hanging Mounting MOUNTING CONDITIONS 6. WALL SURFACE: Varies 7. WALL SIGN: Eye Hooks In Bottom Of Sign 1" From Back NOTES: 1. Fab With (6) Mounting Holes Through Aluminum For Wall Or Hanging Mount 2. Do Not Cut Holes Through Reflective Yellow Vinyl Until Time Of Installation. Only Cut Holes Through Vinyl That Are Required For Type Of Installation Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT Of 19 12 c1ma k EXISTING PROPOSED Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any fashion without the expressed constant of Cima Network, Inc. REAR •RELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations 2. Repair & Refurbish Damaged Corner of Canopy SQUARESIGNAGE •• EXISTING: 4.0 SQ FT PROPOSED: 2.99 SQ FT ALLOWED: 100.0 SQ FT Total For Building Service order to repair the edge of the drive thru canopy has been provided. WORK ORDER #2028741. I --- EXIT------- ._.----- _._._ IL--------- -----------I I L J CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meetthe requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of }hest n. Date: 1.24.19 P P 9 9 9 9 I Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT of 19 13 c1ma k 12" 2'-11 3/4" ©0 FCO LETTERS 14 SCALE: 1-1/2" = 1' 0" (1) REQ'D P1 © SECTION @ FCO LETTERS 14 SCALE: NTS Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any fashion without the expressed constant of Cima Network, Inc. I I I i I I _. ------------ EXIT ---------- I IL--------- -----------I L J CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of }hest n. Date: 1.24.19 P P 9 9 9 9 I COLORS & FINISHES P1.0 PAINT: Red 1. COPY: 1/2" Routed Acrylic Painted Red INSTALLATION HARDWARE 2. HARDWARE: 1/4-20 X 2" Long Studs Threaded Into Backside. Min (3) Per Element. BUILDING & FASCIA CONDITIONS 3. WALL SURFACE: Varies Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT 0119 14 L EXISTING PROPOSED 10'-8" — l a� It ■ Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibited in anyfashion without the expressed constentofCima Network, Inc. All Electric Signs to be manufactured to meet the requirements of Client: Walgreens Ul48 and installed to meetthe requirements of Article 600 ofthe Dwg By: CMC National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding ofthesign. I Date: 1.24.19 SQUARESIGNAGE • • REFACING WITH IDENTICAL SIZED FACE. Job#: 7405 Store* 71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 E!2 ®Oft REFACE 16 SCALE: 3/4" = TO" (2) RECIT 27.3 sf — 9'-0 3/8" — USE TRACING This is an original, un unpublished drawing, created b Cima Network Inc. It is submitted for Cima Network Inc. office: 267.308.0575P g, y 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a projectbeing proposed by Cima Network, Inc. iris notto be shown to anyone outside your organization, nor is it io be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibited in any fashion without the expressed constent of Ci ma Network, Inc. 1E All Electric Signs to be manufactured to meet the requirements of Client: Walgreens q Ul48 and installed to meetthe requirements of Article 600 ofthe National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of thesi n. Date: 1.24.19 P P 9 9 9 9 I COLORS & FINISHES Pf1. ❑FACE: Opaque White V1. VINYL: 1 st Surface 3M 3730-53L Env Cardinal Red V2. VINYL:1 st Surface 3M 3630-8057 Blue (PMS542c REFACE CONSTRUCTION 1. FACE:.177" Thk Opaque White Polycarbonate w/1st Surface Vinyl. Use Tracing To Cut Face INSTALLATION 1. New Retainer Required Job#: 7405 Store* 71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT of 19 16 c1ma k TLeave As -is EXISTING This is an original, un unpublished drawing, created b Cima Network Inc. It is submitted for Cima Network Inc. office: 267.308.0575P g, y 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a projectbeing proposed by Cima Network, Inc. iris notto be shown to anyone outside your organization, nor is itto be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibited in arryfashion without the expressed constentofCima Network, Inc. EXISTING All Electric Signs to be manufactured to meet the requirements of Client: Walgreens q Ul48 and installed to meetthe requirements of Article 600 ofthe National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes proper grounding and of thesi n. Date: 1.24.19 P P 9 9 9 9 I DIRECTIONALS 1. Remove Damaged Directional and Leave Other As -is Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT Of 19 17 Project Name: Walgreens #17626 Date Requested: Street Address: 314 ROLKIN ROAD Date Completed: 1-8-19 City, ST Zip: Charlotteville, VA Contact for Zoning/Permitting: Bart Contact Phone Number: 434-296-5832 Address: Jurisdiction: City/Town: or, County of: Albermarle City, ST Zip: 1.Special codes, overlays, sign districts, PUD's, colors, historical or other restrictions regarding freestanding or building 2. Are there any approval boards? ❑ Yes ® No Planning Review? ❑ Yes ® No A. What documents are required and when? Architectural Board? ❑ Yes ® No Design Review? ❑ Yes ® No B. How often does the board meet? Other: C. When is the next available board meeting date? 3. Zoning C1 1 4. Permit Application Fee (if known) 5. Is ordinance available online? Please provide website and specify location of page that contains the ordinance: municode 6. Permit Timeframe (incl. expiration date): 10-20 days 7. Will code be changed in the near future? No 8. Permit Process as described in local code: In the C-1 and CO districts, 1.5 square feet per 1 linear foot 9. Formula for calculating wall sign square footage of establishment structure frontage, not to exceed 100 square (max sq footage - primary & secondary signs) feet; 10. Are Sign calculations boxed or other means of determining? box 11. Sq Ft allowance for elevations: Primary: (L) Side: (R) Side: Rear: 12. Are allowances transferable? Walls with fronts 13. Total # of Wall Signs allowed per elevation: above 14. Min/Max height from top of sign to grade: NA 15. Can sign exceed roofline? 16. Maximum Letter Height: 17. Maximum projection from building face: 18. Internal illumination allowed? ❑ Yes ® No NA above 19 Yes ❑ No 1 per street frontage, or 2 per entrance, per lot with 100 or more feet of continuous street frontage plus 1 per lot if the lot is greater than 4 acres and has more than 1 approved entrance on its frontage. 32 square feet, plus bonus tenant panels; if more than 1 sign at an entrance, no single sign shall exceed 16 square feet In the C-1 and HC districts overall height, 12 feet; 16 feet in all other districts 21. Are permits required for face changes? yes 22. If existing F/S sign is legal, non conforming, are we grandfathered and able to keep same SF if replacing the cabinet an d/or providing face replacements? Face replacement only 23. Are there any issues with keeping existing F/S signs at existing height in this jurisdiction? NO you can replace face with permit. 24. Number of F/S Signs allowed: 1 25. Height Maximum: 8' 26. Clearance from grade to sign: NA 27. Internal illumination allowed? 0 Yes ❑ No 28. Set -back of sign from right-of-way to property line: 5' from ROW 29. Is permit required? ® Yes ❑ 1 or more per establishment, as authorized by zoning administrator. 24 square feet. Must be 5' from ROW 30. Maximum Sq Footage: above 31. Maximum Height: 6' 32. Does sign(s) count toward square footage? Yes for that type sign. 33. Number of signs allowed: above 34. Internal illumination allowed? ® Yes ❑ No Sign Criteria is reported as presented to us as of the "Date Completed." Cima Network, Inc. is not responsible for changes in local sign code after the completion date, norfor the review process, interpretations, calculations or fees of local authorities. Where required by local authority, it is understood a permit will be obtained prior to manufacture. Information provided herein may notbe used or disclosed without written consent by Cima Network Inc. Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any fashion without the expressed constent of Ci me Network, Inc. All Electric Signs to be manufactured to meet the requirements of Client: Walgreens Ul48 and installed to meetthe requirements of Article 600 ofthe Dwg By: CMC National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding ofthesign. I Date: 1.24.19 Job#: 7405 Store* 71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 9.24.19 7 SHT of 19 18 35. Are temporary or "grand opening" banners ® Yes ❑ No allowed? 37. Are freestanding temporary signs allowed? 1 per street frontage per establishinent. 32 SF. 12 feet, if freestanding sign; 20 feet, if residential wall sign; 30 feet if nonresidential ® Yes ❑No wall sign, but not to exceed the cornice line. 5' from ROW. 1. Is there a variance appeals process? ® Yes ❑ No only 3. Variance Meeting Date: MONTHLY 5. Time required to process: 90-120 DAYS Plot Plan Installation Drawings Graphic Drawing 7. Is current sign under a variance? 36. Is permit required? ® Yes ❑ No 38. Is permit required? ® Yes ❑ No 2. Estimated Variance Application Fee? 1500.00 4. Application Deadline: TBD ® Photo of Existing ® Building Elevations ® Selected Engineering Drawings ❑ Yes ® No # of sets of prints Legal Description Stress Analysis Other: 1. Are signed/sealed engineering drawings required? ❑ Yes ® No 2. How many sets? 3. Calculations and drawings both required? [:]Yes ® No 4. Building / Structural code required? ❑ Yes ® No 5.Buildine code vear: 1. Are signed/sealed engineering drawings required? 3. Calculations and drawings both required? 4. Electrical code year: 5. Check all necessary items: ® Electrical hook-up included with sign permit ® List of UL numbers ® Yes ❑ No ® Yes ❑ No 2. How many sets? 3 ® Electrical permit required by licensed electrician ® UL Label visible after installation 1. Inspections required? 2. Third party inspections required? 3. Contact for inspection: 4. Advanced notice requirements: ® Yes ❑ No ❑ Yes ® No Formula for calculating wall sign square footage (max sq footage — primary & secondary signs) Sq Ft allowance for elevations: Primary: Formula for calculating F/S sign square footage (max sq footage — primary & secondary signs) Sign Criteria is reported as presented to us as of the 'Date Completed." Cima Network, Inc. is not responsible for changes in local sign code after the completion date, nor for the review process, interpretations, calculations or fees of local authorities. Where required by local authority, it is understood a permit will be obtained prior to manufacture. Information provided herein may not be used or disclosed without written consent by Cima Network, Inc. Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibited in any fashion without the expressed constent of Ci me Network, Inc. Contact Information: (L) Side: (R) Side: Rear: All Electric Signs to be manufactured to meet the requirements of Client: Walgreens Job#: 7405 Store#: 71626 Ul48 and installed to meetthe requirements of Article 600 ofthe National Electrical Code and/or other applicable local codes. Dwg By: CMC Address: 314 Rolkin Rd. This includes proper grounding and bonding ofthesign. I Date: 1.24.19 Charlottesville, VA 22911 REV 9.24.19 7