Loading...
HomeMy WebLinkAboutSDP201500010 Letter of Revision 2019-10-08 �oF ALs1,_ e--.*. %el+"M. frIRGiNtt' COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road,North Wing Charlottesville,Virginia 22902-4596 Phone(434)296-5832 Fax(434)972-4126 October 8,2019 Daniel Hyer 113 4th St.NE, Ste. 100 Charlottesville,VA 22902 RE: LOR# 1 for SDP201500010;Cale Elementary School Modular Classroom Tax Map/Parcel Number 09100-00-00-01300 Dear Mr.Hyer, This letter is in response to the attached Letter of Revision Request dated July 24,2019.The Department of Community Development hereby grants approval of this LOR for the following modification to SDP2015-10,depicted on the modified site plan and described below. 1. Installation two new modular classroom units at locations shown on attached plans This change is noted in the attached request and plan.This is the first Letter of Revision for this site.A total of three LORs may be requested after which any further changes to the plan will require submission in the form of a site plan amendment application. Sincerely, Jeff P.Baker Senior Planner Attachments: Letter of Request&Application Revised Site Plan Application for Letter of Revision ❑ Letter of Revision =$108 This application may require additional review by the Fire Marshal. Fees in addition to those shown on this application may be required as required by the Fire Prevention Code Fee Schedule. A copy of the schedule is available from the Fire Marshal. Final Site Plan Name and Number: Cale Elementary School Security Improvements 2015; SDP2015-00010 Contact (who should we contact about this project) Daniel Hyer Street Address 113 4th St NE, STE 100 City Charlottesville State VA Zip Code 22902 Phone Number (434)262-0169 i:mail dhyer@line-grade.com Owner of Record County of Albemarle School Board Street Address 401 McIntire Road City Charlottesville State VA Zip Code 22902 Phone Number (434)975-9340 Email shoopmann@k12albemarle.org Applicant Daniel Hyer Street Address 113 4th Street NE; STE 100 City Charlottesville State VA Zip Code 22902 Phone Number 434-262-0169 Email dhyer@line-grade.com SUBMITTAL REQUIREMENTS: ❑ The appropriate fee, The site plan number that the change applies to, m A request letter describing the proposed changes from the owner or authorized agent, 23 4 copies of the plan that shows the proposed changes, Changes must be shown on the sheet or sheets from the approved final site plan,or on an 11"X17"copy of that portion of the approved final site plan. Owner/Applicant Must Read and Sign I hereby certify that the information provided on this application and accompanying information is accurate,true and correct to the best o y nowle ge elief. July 24, 2019 Signature , ent Date Daniel C. Hyer 434-262-0169 Print Name Daytime phone number of Signatory FOR OFFICE USE ONLY LOR# Fee Amount$ f v i pt Date Paid ilk By who? Nip Receipt# Ck# IJjiy:__41/0 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434)972-4126 REVISED 4/23/2018 Page 1 of I LINE I GRADE CIVIL ENGINEERING July 24, 2019 Albemarle County Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attention: Cameron Langille RE: LOR Application for SDP201500010 Dear Cameron, On behalf of the County of Albemarle Schoo► Board, we submit this Letter of Revision (LOR) request letter to describe the proposed changes to the above referenced site plan. Description of Proposed Site Amendment Albemarle County Public Schools is currently under efforts to procure much needed additional classroom space. As an intermediate step while the school raises money for a building expansion, modular classroom units would be installed (as has been done before on this site prior to previous building expansions). Based on the direction of County staff, we have prepared a Letter of Revision application for this work. This application proposes two (2) new modular classroom units, one of which will be a 'double long' unit (see attached plans). These would be installed sequentially as need arises, starting with unit 1. Unit 1 will be a newly procured unit, whereas unit 2 could be newly procured, or a relocation of one of the existing units already on site. Power, data, and water utilities will be provided directly from the existing building. A small pressure sanitary lateral with a grinder pump at unit 1 will allow the units to be sewered without the need for extensive rock excavation or costly sanitary main extension. Field observations and previous site plan amendments indicate an existing fire hydrant in the vicinity of unit 1 that would require relocation approximately 30'to the north to allow for the unit's installation. Fire coverage has been analyzed, and the relocation will not LIN E adversely affect life safety. The existing water easement will be adjusted accordingly. Access to the existing fire access road will be maintained with the installation of both G R A D E units. Unit 2 will require a small timber retaining wall (less than 48") in order to provide a flat CIVIL ENGINEERING building pad for the unit. Details of this can be found in the attached plans. 113 4"St.NE;STE 100 CHARLOTTESVILLE,VA 22902 TEL:(434)262-0169 LINE-GRADE.COM LINE GRADE CIVIL ENGINEERING September 5, 2019 Albemarle County Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attention: Cameron Langille and Jeff P. Baker RE: Comment Response Letter LOR Application for SDP201500010 Dear Jeff, On behalf of the County of Albemarle School Board,we offer the following responses and plan revisions to comments dated August 12th, 2019. Our responses are in bold italic text below each comment. With these comments verified and incorporated, we submit this project for approval. Utilities—Jeff Baker 1. ALL water lines, sewer lines, and fire lines from the main to the structure MUST have a visual inspection performed by the building department. This note has been added to the general notes page under Utilities.See revisions on CO.1 number 9. Earth Work and Site Conditions—Jeff Baker 2. All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks. This note has been added to the general notes page under Earth Work and Site Conditions. See revisions on CO.1 number 10. General Construction—Jeff Baker 3. Accessible routes and features must meet ICC A117.1-09. LINE + This information has been added to the general notes page under General Construction. See revisions on C0.1 number 28. GRADE ACSA CIVIL ENGINEERING 4. Submit 3 copies to ACSA for review Acknowledged. 113 4'"STREET NE,STE.100 g CHARLOTTESVILLE,VA 22902 LINE-GRADE.COM LOR Application for SDP201500010 Responses to 15t Submission Comments September 5, 2019 I Page 2 5. The existing water main is 8" diameter The existing water main has been changed to the proper measurement. See revisions on C1.0. 6. Ensure the force main crosses under existing water main We have shifted the location of the proposed fire hydrant, truncated the water main and redirected the force main so that it does not cross the water main.See revisions on C1.0. 7. There is an existing easement on the neighboring parcel for a future water main connection. Show this easement in relation to the property line, DB 4425 PG 325. We have included this easement on the drawings. See revisions on C1.0. 8. Shift hydrant away from trailers. Hydrant location has been approved by Deputy Fire Marshal, Shawn Maddox. See attached email. 9. Leave a portion of existing water main as stub out for future water connection. More details can be given once the above easement is shown. Comment noted. See revisions on C1.0. LINE + GRADE CIVII FNGINFFRINC; 113 4th STREET NE,STE.100 CHARLOTTESVILLE,VA 22902 LINE-GRADE.COM 9/4/2519 Line and Grade,LLC Mail-Fwd:LOR for SDP2015-10 Cale Elem.Modular classrooms L I N E+G R A D E Willie Woodard <wwoodard@line-grade.com> Fwd: LOR for SDP2015-10 Cale Elem. Modular classrooms Shawn Maddox<smaddox@albemarle.org> Wed, Sep 4, 2019 at 1:00 PM To: "Daniel @ Line and Grade"<dhyer@line-grade.com> Cc: Richard Nelson <rnelson@serviceauthority.org>, Jeffrey Baker<jbaker@albemarle.org>, Sheila Hoopmann <shoopmann@k12albemarle.org>, Willie Woodard <wwoodard@line-grade.com> All—I believe the proposed location between the two buildings makes the most sense for this existing site. Fire Rescue will have no objections to the LOR with the hydrant equidistant between the two buildings. Shawn ALAE*IARLE[OLAtVTY Shawn N. Maddox, CFO, EFO Deputy Fire Marshal Office: 434-296-5833 Cell: 434-326-2623 From: Daniel @ Line and Grade <dhyer@line-grade.com> Sent: Wednesday, September 4, 2019 11:09 AM To: Shawn Maddox <smaddox@albemarle.org> Cc: Richard Nelson <rnelson@serviceauthority.org>; Jeffrey Baker<jbaker@albemarle.org>; Sheila Hoopmann <shoopmann@k12albemarle.org>; Willie Woodard <wwoodard@line-grade.com> Subject: Re: FW: LOR for SDP2015-10 Cale Elem. Modular classrooms Shawn, I'm resending the image we shared a few days ago, see below.As currently positioned, midway between the two buildings, the hydrant would be approximately 26'from the buildings, blue circles. You'll note that the red circle is an approximation of a 40' radius. However, the existing conditions beyond the location of the hydrant and the property boundary is a large rock deposit. Please confirm you are accepting of this approach. https://mail.google.com/mail/u/0?ik=381 e61 b56e&view=pt&search=all&permmsgid=msg-f%3A1643764991322907597&dsqt=1&simpl=msg-f%3A1643... 1/9 `'9/4/11019 Line and Grade,LLC Mail-Fwd:LOR for SDP2015-10 Cale Elem.Modular classrooms +va:txP*'.AbUII. --NNW,NMAI OM*"Oa E! N1t/L1EEtp H!'MMMYIIWV Pi La* {. �4,t4 )113= DEtw.4CtEMO�t rF4�rwAl __ y MMIIAk[tlMtlMA C.N*INs'*AN at* TEN W7N.Ls'*AN iLtJR ' Viky Of NI MAW \TO COMP MAW/to qi*rit ult.1 na+oK u aw+iN NO !�CstfPtlrrtwnarl.rt IX MAIM Esr'* WIN IMO �i \" �wwcnator rx rnE+eawwr. �iw>w.elluetwttautr 'J 'ti•�vaarrecwrrcrwcwrHr utuanrtxt sE tm�rw mtth f 1 om*QYp(1M tiHIMRii '\ V SetterfE EA kg,*^n[II3k\I /I AV 0Wapl pY SEE tt�5���tE�T � »,u Daniel Hyer Line + Grade 434-962-2430 On Wed, Sep 4, 2019 at 10:49 AM Shawn Maddox<smaddox@albemarle.org>wrote: I'd agree with Richard's suggestion to move the hydrant between the two buildings to see what distance from each building will be in that location. Shawn Al.BEMARLE COILAJTY Shawn N. Maddox, CFO, EFO Deputy Fire Marshal Office: 434-296-5833 Cell: 434-326-2623 From: Richard Nelson <rnelson@serviceauthority.org> Sent: Wednesday, September 4, 2019 10:37 AM To: Jeffrey Baker<jbaker@albemarle.org>; Shawn Maddox <smaddox@albemarle.org> Cc: Daniel @ Line and Grade <dhyer@line-grade.com> Subject: RE: FW: LOR for SDP2015-10 Cale Elem. Modular classrooms https://mail.google.com/mail/u/0?ik=381 e61 b56e&view=pt&search=all&permmsgid=msg-f%3A1643764991322907597&dsqt=l&simpl=msg-f%3A1643... 2/9 J 2018 - c INF+`-',RA E, L r i t I t I r. E I — G LJ t u , — 1 r ' I 4 I SCOPE OF `CORK® THIS PROJECT CONSISTS OF THE INSTALLATION OF TWO MODULAR CLASSROOM UNITS. IT IS ASSUMED THAT UNIT I WILL BE INSTALLED IMMEDIATELY AND UNIT 2 WILL BE INSTALLED IN THE FUTURE. ANCILLARY WORK INCLUDES AFIRE HYDRANT RELOCATION, SIDEWALK CONNECTIONS, AND UTILITY HOOKUPS, INCLUDING THE INSTALLATION OF A PRIVATE SANITARY SENAIER GRINDER PUMP AND PUMP LINE FOR UNIT 1. PROJECT INFORMATION - OWNER: COUNTY OF ALBEMARLE SCHOOL BOARD 401 MCI NTI RE ROAD CHARLOTTESVI LLE, VA 22902 CONTACT: SHEILA HOOPMANN PHONE: 434.975.93410 x11016 ENGINEER: LINE r GRADE ( CIVIL ENGINEERS 113 4TH STREET NE CHARLOTTESVIL LE, VA 22902 CONTACT: DANIEL C. HYER, PE PHONE: 434.262.0169 SURVEYOR: TIMMONS GROUP (2005 SURVEY) 603 PRESTON AVE #200 CHARLOTTESVI LLE, VA 22903 CONTACT: FRANK SLINSKY PHONE: 434.295.5624 PARCEL INFO: PARCEL : 09100-00-00-01300 1757 AVON°STREET EXT. CHARLOTTESVI LLE, VA 22902 ZONED: R1 LEGAL AREA: 15.96 AC STANDARD ABBREVIATIONS �' •liffimplMIMISMA PHONE: VOIP (ACPS INTERNET CONTRACTOR) WATER: ALBEMARLE COUNTY SERVICE AUTHORITY STORM SEXIER: ALBEMARLE COUNTY SANITARY SEWER: ALBEMARLE COUNTY :SERVICE AUTHORITY ID INSIDE DIAMETER R&D REMOVE AND DISPOSE: ABAN ABANDON LA LANDSCAPED AREA R&R REMOVE AND RESET AC ACRES LF LINEAR FEET R&S REMOVE AND STACK ADJ ADJUST LOD LIMITS OF DISTURBANCE SB SOUTHBOUND APPRO X APPROXIMATE LT LEFT SF SQUARE FEET ASPH ASPHALT MAX MAXIMUM SSD STOPPING SIGHT DISTANCE I BASELINE MIN MINIMUM STA STATION BLDG BUILDING ME MATCH EXISTING SW SIDEWALK BM BENCHMARK NIC NOT IN CONTRACT TEMP TEMPORARY CENTERLINE N.T.S. NOT TO SCALE TRANS TRANSITION CF CUBIC FEET NB NORTHBOUND TYP TYPICAL CG CURB AND CUTTER OC ON CENTER WB WESTBOUND CONC CONCRETE OD OUTSIDE DIAMETER WSEL WATER ;SURFACE ELEVATION CONST CONSTRUCTION PRKG PARKING D➢ DROP IN LET PROD PROJECT DND DO NOT DISTURB PROF PROPOSED EB EASTBOUND PVMT PAVEMENT EL ELEVATION PM PAVEMENT MARKING EX EXISTING REM REMOVE FND FOUNDATION ROW RIGHT—OF—WAY GRVL GRAVEL RT RIGHT HC HANDICAP LIGN MENT/GRADING ABBREVIATIONS BC BACK OF CURB PCC POINT OF COMPOUND CURVATURE BR BOTTOM OF RAMP PI POINT OF INTERSECTION BVCS BEGIN VERTICAL CURVE STATION PNT POINT BVCE BEGIN VERTICAL CURVE ELEVATION PR PROPOSED ELEVATION BW BOTTOM OF WALL PRO POINT OF REVERSE CURVATURE D OR A DELTA ANGLE PT POINT OF TANGENCY EG EXISTING GRADE PVC POINT OF VERTICAL CURVATURE EP EDGE OF PAVEMENT PVI POINT OF VERTICAL INTERSECTION PVT POINT OF VERTICAL TANGENCY EVCS END VERTICAL CURVE STATION EVCE END VERTICAL CURVE ELEVATION R RADIUS TAN TANGENT DISTANCE FG FINISHED GRADE TO TOP OF CURB FL FLOWLINE THT THROAT HP HIGH POINT TR TOP OF RAMP INV INVERT TW TOP OF WALL IL LENGTH STA STATION LP LOW POINT LVC LENGTH OF VERTICAL CURVATURE SIP SADDLE POINT OFF OFFSET PC POINT OF CURVATURE VIC"INITY MAP S IS Leo T9 = 0, Y00' 64 L, L f A All #""" � i4� F § 41 Y �F 'io p f 3 lam 1 y� �I " PROJECT - s r�``,..`r"yy�`'>. .11` ? ``�d:�'"' id" � �'"^`"•t e, t�, �.. (t y . LOCATION a yt 1 � { d , S P F b +F P{ j "§i 5 � t y �� •...�. ..ei y' r�<.*` f {�."�.. ,._. �.»:= Via" �f' a,J.y" p i! a , �q T ��4 t e g- f {f it NI„fiy i �. Iry ! f yA fi t' 'cif 4 n y > w r Xl d TO " PF r" va Pfl`6*� L! 1 e' e� R X k '.s'✓'A'✓ rs? u 4 w Lu'CATION MAP' !Ili - �� 1� i MTEO SHEET NUMBER SHEET TITLE CO.O TITLE SH EET CO.1 GENERAL NOTES C1.0 SITE AND UTILITY PLAN C1.1 CONSTRUCTION DETAILS 4 TOTAL SHEETS SUBMITTAL LOG SUBMISSION NO. DESCRIPTION — RECIPIENT — — SUBMITTAL DATE 1 100% FOR CLIENT APPROVAL ALBEMARLE COUNTY PUBLIC SCHOOLS 07f22f2019 2 1ST SUB�tI ISSION DEPARTMENT OF COMMUNITY 07f24f2O19 DEVELOPMENT FOR REVIEW 3 2ND SUBMISSION DEPARTMENT OF COMMUNITY 9f5f2019 DEVELOPMENT FOR APPROVAL 4 CD'S FOR PRICING ALBEMARLE COUNTY PUBLIC SCHOOLS 9f 1Cf2019 5 CD'S FOR PRICING ALBEMARLE COUNTY PUBLIC SCHOOLS 9/27/2019 C FOR SIGNATURE AT CCD COM➢ A UNITY DEVELOPMENT FOR 10/03/2019 SIGNATURES W z Lu Lu ui i L) 0, lU ' Y0,0,3312019 DANIEL Ca HYER Lic. No. 45596 ON AV1, g 1 E, 'Al R K 0;:. g N t^ i D k>, FINISHED GRADE P BODY PLASTIC I B D Y` CLEAN AN OUT & CAP 4" CLEAN OUT STACK PRIVATE FORCE MAIN 6" HOUSE CLEANOUT FRAME &_ COVER CAPITOL FOUNDRY BPJASS CAP (NON —TRAFFIC) OR VB-9-S (TRAFFIC — BEARING) CLEAWOUT TO EXTEND ABOVE GROUND A MIN. OF 3 FEET DURING INSTALLATION OF MAIN LINE. PLUMBER SHALL CUT STACK TO FIN. GRADE & REPLACE G.O. & PLUG WHEN PRIVATE FORCE AllAlN IS CONNECTED TO LATERAL TEE, WYE, TEE/IA/YE OR COMBINATION OF INYE 84 450 BEES+ID FITTINGS SHALL BE SIZED AS PIPES REQUIRE LONG RADIUS 90' BEND `I I—D" MIN. dlrif��1 _ MAIN LINE OR MANHOLE TREATED ED TIMBERS LAID WITH OVERT-APPING JOINTS C" x C" MIN. DIMENSION FINISHED GRADE Im T 0 Lu I Ll I ter' C� i Lit 0_' 1 � I 0 a § s FIN ISH ED GRADE FLAT LAN D I N G I AREA � a 27 is 9 F fillIN TOPSOIL t r Ia s — GRANULAR FILL " NON —WOVEN GEOTEXTILE FILTER FABRIC t* ; PURRITO WRAPPED AROUND STONE �. t3 a Y 1' f i x I y 2 L ..,_�..,.nM� ... "'...',,..� h .. °'t I !, COMPACTED Y pN BACKFILL 3s C § t 'ti, a r, 'r i i i§ C.^ i ug r E z _ MIN. 5 GALVANIZED OR EPDXY M I , COATED BAR DRIVEN THROUGH .'� UNDERSIZED HOLE --_ ,I01- TEE, WYE, TEENTYE OR 45" ON —CENTER MAX. SPACING COMBINATION OF WYE & 45' BEND FITTINGS SHALL BE SIZE D AS REFIRED. {NOTE:1A0AL LS WITH RETAINED HEIGHT GREATER THAN 18" SHALL HAVE A 12:1 BATTER. r i FORCE E LATERAL C"ONNE —Fa TO GRAVIT"y' LATERAL TIMBER ETAININWALL — FINISHED GRADE 5` (UNLESS OTHERWISE NOTED) — �r� CROSS SLO PE I OPE SLOPED TO DRAIN �--- a 1 5 i E £ 8 r e ~ I, �5 Aeh I: a b a € f V 777 i P a- rW �4 2T ° ;., T II s � va _a- ., a. x^ r._ >7 a. .. +r :,,u. ,'.S ., n• x f eLt ^ .. .. w..,. ..v L § 1 , t� $ P P v & 4 6 w.nu S 6" X 6" W2.9 \ W2.9 W.W.F. CENTERED IN CONCRETE s.II I r �fIIN. 4 THICK, 3000 PSI CONCRETE .. w 3 E Oar VDOT 2 i A STONE BASE I (4 3 If y Q Fl. I I �,,,,„..,..w ,,.„„a.. PR EMOLDED JOINT FILLER (WHERE SIDEWALK ABUTS PAVEMENT, CONCRETE, OR CURB) EX. GRADE \ i8ll -- TRENCH -- s 3 h 4 y_ Y S ,Z i 2. ss z I P sY I I t . J 9 k 3 ✓ 1 R ! d. a �w I. 1 0 dP A I 1 I 1 .,I 0 u... N . I I F" 5 2" D IA. SAN I TARY FORCE LATERAL =_ 2" TOPSOIL 9 { 3 II Y 4 9 6 1 3 I I d{ &_ j 3 UNDISTURBED 1 tl r I �AIRTH COMPACTED BACKFILL — — —-------- -- _ — r V 6��,� s4 S as <o ;.. l� 6aa 21ryt I ,: a — r s 10, r I IiAF IWNTT -Ill f n H/_ r" ___... Ld m� NIX c ! r Mn I- ---i— — tT r" t AS ^n.N t f ••.. U K, i CiYRMf _` 1 it `.� i i 20Fl4D I3 L1 -. �CS�J — _ _ j — r---- — � I 1+.C 96 t Parzcrl 6 -f P. z 'i ' t4 7 X111F3� i- I _ _ =„t IP it [ Gi2 Yt" "Tit fk L I, 11IR N F E ^`! s%,5 -CI 11A 3t`i }= s' IL 11^f N 1x!!r 1 5 LV iqJ G ,9tF r a I ­=--�:1 t �� ��,� ,. :.—. �=,:' J f '1NkF M1E,Ni 1669.5 c,. €S_ Ma EC(.E♦= : SF,O,. ECPEr_ f .:"/( %r� `E d r I „L.vS E-_..'s ,.36>P'. Es. : ,Mr .xn rr,,:•., U` ----i` jCUST0MER APPROVAL E. TEf I — _ _ — FIRST STRING SPACE INC (SALESi',P:L .ilk -SPP `d.11-`� zta ,x+fl 'f) §. e': F.r T PFyrP. P 6 uR; IA 31n4? i�k2) ^_ �t-04..., Nj,^.2En fi 1TF er_sE tIAwrwt^PLA, L .IRRE07016 ABOW eF ON s +VTL,,-FIT A `,.Nx RE{t1T CEO NOT �I , :T U`!-II AN C, ,r1T U [C A\E: ",, d >,+E ul L ,nit oE.,.; ,r I.. !t _�• _ I IL.S a , .4. .., ,w SIDE: a . s � ..-_ .. ___-..— --- � AC, [-ILA d ML: ORDER, w_ PLE.4E e wr IF Eu AUNE 41 TiftAalOI Tn,7{; ix C ODE ;16r ---- aa Hr u1 N_o r r�rt. Nu n new r 1Hs PreolEcr. _ t.�l.l - - — kt t,icazzf u F F,P t TElrs F eE ra .�I E u,�cl , u Y±'3� g �"f3R a'AC� itr __. _,,....... ___._. ..oce>r, +,i r I EI lowsa :. RAN :,a._ 3 T�G�J C1F1417��CE4A C3� 3➢CdAu{��1dT�i�G€�I_1�s} ti�AS�IiI��a����i�-R 302». aac GENERIC DUL UL S O � LAYOUT (UNIT 1 WILL t U T �I D BY CLIENT NOTE, HYDRANT MUST DE QUIPPED WITH CHARLOTTES— VILLA THREADS WHICH IS THE LOCAL STAiNTIARD. I LENGTH OF BLANCH DIARIES mlbl ?7J' 2' To1O' 7ci Cil. FT. VALVE ,gyp #aSTUG�iu-q ��J �ff �f a F GATE 42', I111 VAf.AJ% TEE 2500 F.S.I. CONCRETE BASE AND THRUST BLOCK AGAINST UNDISTURBED STABLE 541L STEEL PILE ! RESTRAINED JOINT" FITTINGS WHEN 'RiE SOIL IS DISPURULD OR +sV-0M A f 1YCiRANT IS LOCATED IN A FILL, IN ADDITION TO POURING COfICRF:TE, A STEEL PILE SHALL BE USED AS ADD1110ilAL SUPPORT. NOTE . I. SURRGU D WEEP HOLES VIM GRtVrc.,L AND KEEP ,-REE OF CONCRETE. �. hfo-lltNT,AtN A .'t `i /2' 49S`V. GD''JEFs' FROM THE Pv9AlP3 TO 11-1E FIRE HYDRANT t � DITCHES f ING�UCSIaIfa I h { 3. FINISHED GRADE SHALL SLOPE AWAY FROM THE FIRE HYDRANT AND VALE Hoer, 4, THE GATE VAO& IS ALLOWED 114 SHOULDER OR BEHIND THE DITCH. IT IS NOT ALLOWED IN THE DITH^ 5. FIRE HYDRANTS SMALL BE INSTALL-ED AT LOCATIONS WHERE T&EP HOLES ARE ABOVE THE PREVAILING GROUNDWATER EL VA-HON, IF REQUIRED ID 5E 3N WET AREAS, THE WEEP HOLES SHALL BE PLUGGED AND T14E i-YDRAINT SHALL BE. PUMPED 'DRY. TYPICAL._ FIRE. HYDRANT ASSEMBLY DETAIL N.r S. FIG. 'aVn-4 TD--8 IDEWAL — — — — m LATERAL T E /H — — — _ a FIRE HYDRANT ASSEMBLY DETAIL,D 9 z cc 0 Lu 0 01 OfI�I E-- L�� J ,_j Lli LLJ ��,T .41 xgj0,3%2019 D:ANIEL C. HYER Lc. No, u55R6 APPROVED DCH PROJECT 1907100 LINE + GI_- s A D E "4 X TW591.0 T 3w. 590.0)AA NOTES: lk 7vN\' f % '50'LONG TIMBER RETAINING WALL ► CSI RITE INLE T V IN=576.95' (SEE DETAIL 2/Cl.1) Q1. CONTRACTOR SHALL CONTRACT ALBEMARLE COUNTY SERVICE AUTHORITY AND v v ?UT=5760. 91 PROP.5'CONC. SIDEWALK SHARE A PROJECTSCHEDULE FOR COORDINATION. 2. CONTRACTOR TO COORDINATE WITH ACSA IN REGARDS TO WATER MAIN EXTENSION (TYP, S E E D ETAI L 4/C 1. 1) 450 O�ND TW 593,5 TO HEALTH AND REHAB PARCEL. 3W,590.0 PROP. 4" PVC SAN. LATERAL@ 2% MIN. SLOPE q-1 VO4, �v LOCATION OF WATER VALVE FOR TEMPORARY ► W: 5910 N 9 T' 4 CRAB APPLE N, U CUT-OFF 3W: 590. 0 '/ -N, '-,, LATERALS x (NOTE, THIS DOES NOT CUT-OFF DOMESTIC OR 1745 A VON STREET EXTDOMINION CRANE 8 RIGGIN6, INC. T FIRE SUPPLY TO BUILDINGS. ONLY TO HYDRANT PARCEL 0- 09100 00 00 0000 NEAR WORK -ZONE. T 16� k"I D.B. 1237PG. 594 FORCE LATERAL LATERAL AT PROPOSED SANITARY CLEAN OUT 7x ZONED.- L IGH T INDUSTRY C. (SEE DETAIL 1/C1.1),O, PRESENT USE.- INDUSTRIAL t APPROX. UNIT 1 LATERAL INV: 586.6 x- APPROX. UNIT 2 LATERAL INV: 585.6 WATERLINE CROSSING C) 0 A. CONTRACTOR TO EXERCISE CAUTION WHEN TRENCHING r CONCRETE LATERAL TO PASS UNDER WATER IF POSSIBLE ELSE MAINTAIN 18" MIN. CLEAR ALL POSTS FOR FENCE SHALL MAINTAIN 5' (REFER TO UTILITY NOTE 9) Ua LATERAL SEPARATION FROM WATERLINE 1540 FOUNDERS PL CENTER LLC S I ZE AN D M ATER JAL TO M ATC H EX- LATERAL I It Al ell ALBEMARLE HEAL TH CARE INSTALL CLEANOUT ON EX. LATERAL (APPROX. LOCATION) EX. 8" WATERLINE A PARCEL 0- 09100 00 00 01200 APPROX. INVERT ON EX. LATERAL: 583.1 2 MA z, ACPS SHALL PROVIDE ACSA WITH PLAT INDICATING D.B. 4 132 PG. 347 3" WATER SERVICE AND ELECTRICAL PROVIDED FROM BUILDING EASEMENT REVISIONS AS SHOWN HEREIN.PLANNED DEVELOPMENT 14 COD MIXED COMMERCIAL COMMERCIAL 1 �31 PRESENT USE. J)cloj �V r 'T. PROP. NEW 6" FIRE HYDRANTAND GATE . . . . . . .... . 06 "rR49 APPLE ASSEMBLY (TYP, SEE DETAIL 6/Cl.1) DllfC A �P X. ls6 T F/E46 L OC. T17-\\ TERMINATE EX. WATERLINE AT 8" GATE A ,AIVYIA, I-IAIV VALVE (REMOVE ALL PIPE BEYOND G.V.) N NOA'q=581.26' 8" X 6" TEE SANITARY FM CONNECTION INV IN EA,97_=580.67' '11 CAP AND TERMINATE WATER MAIN. REMOVE INV OU 0. 39' RETRAINED ."e, SANITARY FORCE LATERAL SHALL BE 7 ALL WATER LINE AND APPURTANCES BEYOND. INSTALLED IN TRENCH AS SHOWN IN 450 BENDS (2) Al 48" 0 GRINDER PUMP .9 DETAIL 5/Cl.1 AND TESTED IN PLACE (SP-B2WFI0I8H) "w APPROXIMATELY 75'LF OF 2" FM PROP. DOUBLE LONG MODULAR 1�57 A VON STREET EX TfiNDED FORCE LATERAL CONNECTION TO GRAVITY CLASSROOM (SEE DETAIL 3/Cl.1) COWTY OF ALBEMARLE SCHOOL BOARD A� �ov LATERAL AT PROPOSED SANITARY CLEAN OUT rARCEL ID. 09100 00 �o 0/300 _Dlo CONTRACTOR SHALL PROVIDE A LEVEL PAD INSIDE BUILDING. MODIFY DETAIL I/Cl.lAS P.B. 1096 PG. 37 APPROPRIATE UNDER LIMITS OF MODULAR UNIT. ELEVATION OF � RI ZONING. APPROX.INTERIOR INV: 588.22 00 ENT (12" BELOW FF, PER ARCH. FLOORPLANS' PAD SHALL MATCH THAT OF ADJACENT CONCRETE T USE.- ELEM ARY SCHOOL R�SEN SIDEWALK - ELEV. 589.00 j 0" wv 3"WATER SERVICE FROM BUILDING j EX. EASEMENT FOR FUTURE WATER MAIN 4 ku CONNECTION (SEE ESEMENT DETAILS -I/COA) 0� REMOVE EXISTING CONCRETE WALK 4, AND INSTALL NEW CONCRETE PAD, AS SHOWN APPROXIMATELY 10'x'16" CONTRACTOR SHALL CLEAR AND GRUBB EXISTING VEG ETATI 0 N WITHIN LI M I TS 0 F PROPOSED WORK ­41 2 0 i lELECTRICAL PROVIDED FROM CL 0 1 SAKI TARP MAYHOLE C Isc v BUILDING ERIMETERSA TYFENCE F DRAINGE MANHOLEIN VEAST .69' ­hkv i WEST-583.32 ­572. jo 1NC4 UT=580.94' IN=5901, 0/1 A .OUT =579. 83' 11RA 9 APPLE a. a 2 MIAA. SL'E 4 CRAB A FFL REMOVE EX. FIRE HYDRANT AN D 811 WATERLINE TO PROPOSED 8" G_V. (OUTFALL UMKyCWN) Doc .,e ;WOOD S AOR &0G. 2" MAPLE 4' APFLE 2"'CRAB APPLE 14� Ar canm0r,� APPROX. DIRECTION TION (NOTE FIELD LOC. . . . ..... ql 06 tPc6 2 7R� Il ' 121PIN OAK AI f ZS& 15 RCp IA II C -7 it 4 APPLE'S 0 COL UMN---%�"5 > THE (T 1z, k> o q / do �4 c 'Ile 0 CALE ELEMENTARY SCHOOL PROPOSED MODULAR CLASSROOM ... .. ..... .00". 'IS PROPOSED GRADE ADA RAM P EXISTING GRADE TIE DOWN 3:1 Ile UTILITY CONNECTIONS FOOTING PER MODULAR 1.5'- 2' OF FILL ACROSS WORK AREA S T, It TO BUILDING PER PLAN MANUFACTURER SPECS. FOR LEVEL PAD. SEE EARTH WORK NOTES MODULAR CLASSROOM ELEVATION aM 1" 10': 0 10 20 c, ..... . La j SITE AND UTILITY PLAN /69 1" = 20': 0 20 40 01 5jq P Lo (�-[o ta)L No.. a 0 0 0 U) Q Z5 C) < Fn x LILI 0 LL a 2 0 >- 00-0 LLI _j x v 0 UJ < < 2 Lu < Lij _j m LLJ < LLJ CO Lij _j LL] LLJ C) �f— .ttiTH of 7q10,312019 DANIEL C. HYER I .10NAL APPROVED DCH SUBMISSION NO.. 6 PROJECT 1907100 T H E W 0 R K 0 F L I N E + G R A D E c)?`Illq-iIP,iiiC - ,M'illsol��iIi ' ; ig „ a 1. ALL CONSTRUCTION METHODS AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE STANDARDS AND SPECIFICATIONS (VDOT RBS&S), VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK, THE RULES AND REGULATIONS WATER AND SANITARY SEWER CONSTRUCTION SPECIFICATIONS AND STANDARDS FOR THE PLAN APPROVING AUTHORITY AND ANY OTHER APPLICABLE FEDERAL, STATE, OR LOCAL ORDINANCES, CODES, AND LAWS. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL CONDITIONS, MATERIALS, DIMENSIONS LOCATIONS AND EXISTING ELEMENTS TO REMAIN IN THE FIELD BEFORE PROCEEDINGS WITH ANY WORK. IF CONDITIONS VARY FROM WHAT IS REPRESENTED IN THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFYTHE ENGINEER. 3. EXISTING CONSTRUCTION SHOWN IN THESE DRAWINGS SHALL BE USED AS RELATIVE REFERENCES AND ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR IF DEEMED CRITICAL FOR PROPER EXECUTION OFTHE WORK. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUST CONTROL MEASURES. 5. PROVIDE ,'ADEQUATE PROTECTION FOR THE EXISTING BUILDINGS, BUILDING OCCUPANTS, VEHICLES AND PEDESTRIANS AT ALL TIMES IN ACCORDANCE WITH OSHA AND ALL APPLICABLE STATE AND LOCAL CODES. 6. MATERIALS AND EQUIPMENT SHALL BE STORED IN APPROVED AREAS TO PREVENT IMPACTS ON VEHICLES AND PEDESTRIANS. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR MEASURES TAKEN TO ENSURE VEHICULAR AND PEDESTRIAN SAFETY THROUGH THE ENTIRE DURATION OF THE WORK. SAFETY IS PARAMOUNT. 7. EQUIPMENT AND MATERIALS SHALL BE STORED IN DESIGNATED AREAS AND SHALL NOT ENCUMBER THE OWNER'S OPERATIONS, SURROUNDING RIGHT OF'WAY, OR ADJOINING GROUNDS. 8. ALLWORK AREAS SHALL BE CLEANED DAILY. 0. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF BUILDINGS ADJACENT TO WORK AREAS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS OF DAMAGES RESULTING FROM CONSTRUCTION ACTIVITIES. 10. SECTION CUTS AND DETAIL CALLOUTS INDICATED IN THE DRAWINGS ARE TYPICAL FOR THE PROD ECT. THEY ARE TO BE CONSIDERED TYPICAL FOR SIMILAR CONDITIONS AND HAVE NOT BEEN SHOWN EVERYWHERE THEY APPLY. 11. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR JOB SITE SAFETY. 12. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL CONSTRUCTION. 13. SYM BOLS IN TH E DRAWINGS ARE NOT TO SCALE. 14. ALL WORK SHALL BE LAID -OUT PRIOR TO INSTALLATION OF NEW WORK BASED ON MEASUREMENT OF EXISTING CONSTRUCTION AND EXISTING CONSTRUCTION DESIGNATED TO REMAIN AS PART OFTHE PROJECT, DO NOT START INSTALLATION OF WORK UNTIL LAY -OUT IS COMPLETE AND POTENTIAL CONFLICTS HAVE BEEN IDENTIFIED AND ADDRESSED. 15. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO THE EXISTING BUILDINGS AND ADJACENT GROUNDS AND PROPERTY CAUSE BY THE CARELESSNESS OR NEGLECT OF HIS WORKMEN. DAMAGE TO PORTIONS OFTHE PROPERTY INOT SUBJECT TO WORK UNDER THE CONTRACT SHALL BE REPAIRED TO THE FULL SATISFACTION OFTHE OWNER AND ENGINEER, ATTHE CONTRACTOR'S EXPENSE. 16. PROTECTION OF THE WORK: PROTECT EFFECTIVELY ALL MATERIALS AND EQUIPMENT DURI'iNG THE ENTIRE PERIOD OF CONSTRUCTION. REPLACE MATERIALS AND EQUIPMENT DAMAGED, LOST OR STOLEN WITHOUT ADDITIONAL COST TO THE OWNER. 17. PROTECT EXISTING MATERIALS DURING INSTALLATION OF TEMPORARY PROTECTION AND CONSTRUCTION. DO NOT DEFACE OR REMOVE EXISTING MATERIALS IF INTENDED TO STAY. ATTACHMENTS OF TEMPORARY PROTECTION TO EXISTING CONSTRUCTION SHALL BE APPROVED BY THE ENGINEER PRIOR TO INSTALLATION. 18. OBTAIN ENGINEER REVIEW AND WRITTEN APPROVAL IN THE FORM OF A CONSTRUCTION CHANGE DIRECTIVE OR SUPPLEMENTAL INSTRUCTION BEFORE MAKING CHANGES OR ADDITIONS TO CONSTRUCTION OR REMOVING MATERIALS THAT WERE INTENDED TO REMAIN. 19. NOTIFY ENGINEER OF VISIBLE CHANGES IN THE INTEGRITY OF MATERIALS OR COMPONENTS VNIHETHER DUE TO ENVIRONMENTAL CAUSES INCLUDING BIOLOGICAL ATTACK, UV DEGRADATION, FREEZING OR THAWING OR DUE TO STRUCTURAL DEFECTS INCLUDING CRACKS, MOVEMENT OR DISTORTION. DO NOT PROCEED WITH WORK IN QUESTION UNTIL DIRECTED BY THE ENGINEER. 20. WHERE MISSING FEATURES ARE INDICATED TO BE REPAIRED OR REPLACED, PROVIDE FEATURES WHOSE DESIGNS ARE BASED ON ACCURATE DUPLICATIONS RATHER THAN ON CONJECTURAL DESIGNS, SUBJECT TO APPROVAL OF THE ENGINEER. 21. WHERE WORK REQUIRES EXISTING FEATURES TO BE REMOVED, CLEANED AND REUSED, PERFORM THESE OPERATIONS WITHOUT DAMAGE TO THE MATERIALS THEMSELVES, TO ADJACENT MATERIALS, OR TO THE SUBSTRATE. WHEN CLEANING, MATCH SAMPLES OF EXISTING MATERIALS THAT HAVE BEEN CLEANED AND IDENTIFIED FOR ACCEPTABLE CLEANING LEVELS. AVOID OVER CLEANING TO PREVENT DAMAGE TO EXISTING MATERIALS DURING CLEANING. 22. TEMPORARY MATERIALS MAY BE NEW OR USED, BUT MUST BE ADEQUATE IN FOR REQUIRED USAGE, MUST NOT CREATE UNSAFE CONDITIONS AND MUST NOT VIOLATE REQUIREMENTS OF APPLICABLE CODES AND STANDARDS. 23. CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE FIRE PROTECTION IN THE FORM OF FIRE EXTINGUISHER OR OTHER EFFECTIVE MEANS OF EXTINGUISHING FIRE, READY FOR INSTANT USE, DISTRIBUTED AROUND THE PROJECT AND IN AND ABOUT TEMPORARY, INFLAMMABLE STRUCTURES DURING CONSTRUCTION OF WORK. EXISTING FIRE HOSE CONNECTIONS SHALL BE ACCESSIBLE AT ALL TIMES BY FIRE DEPARTMENT PERSONNEL. MATERIAL SAND DEBRIS SHALL NOT BE STORED IN FRONT OF THE CONNECTION, THUS PREVENTING ACCESS. THE CONTRACTOR SHALL COORDINATE ACCESS PROCEDURES WITH THE FIRE MARSHALL. 24. GASOLINE AND OTHER FLAMMABLE LIQUIDS SHALL BE STORED AND DISPENSED FROM UL LISTED SAFETY CONTAINERS IN CONFORMANCE WITH THE NATIONAL BOARD OF FIRE UNDERWRITERS' REOOM M ENDATIONS. 25. SUBMITTALS ARE NOT REQUIRED IF CONTRACTOR ELECTS TO USE THE PROPRIETARY PRODUCTS LISTED. SUBMITTALS WILL BE REQUIRED IF CONTRACTOR WISHES TO USE ALTERNATE PRODUCTS. ALLA,LTERNATE PRODUCTS ARE SUBJECT TO REVIEW AND APPROVAL BY THE ENGINEER AND OWNER. 26. CONTRACTOR SHALLCALL MISS UTILITYAT 1-800-552-7001 BEFORE CONSTRUCTION COMMENCES. 27. TREE AND PLANT ROOTS OR BRANCHES THAT MAY INTERFERE WITH THE WORK SHALL BE TRIMMED OR CUT ONLY WITH THE APPROVAL OFTHE OWNER AND ENGINEER. ANY TREES OR PLANTS WHICH ARE SHOWN TO REMAIN THAT DO NOT INTERFERE WITH THE WORK, BUT ARE DAMAGED BY CONTRACTOR OR HIS SUB -CONTRACTORS, SHALL BE REPLACED BY CONTRACTOR AT NO ADDITIONAL COST. 28. ACCESSIBLE ROUTES AND FEATURES MUST MEET ICC A117.1-00 1. CLEARING AND GRUBBING SHALL BE CONFINED TO THOSE AREAS NEEDED FOR CONSTRUCTION,, AND AS SHOWN IN THE DRAWINGS. 2. DISTURBED AREAS BEYOND THE ROADWAY CURB AND WHERE INDICATED ON THE PLANS SHALL RECEIVE TOPSOIL AS NECESSARY AND AS DIRECTED. SEEDING MIXTURE SHALL BE DETERMINED BY THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK SECTION 3.32 3. CONTRACTOR IS PERMITTED TO WORK IN THE PUBLIC RIGHT-OF-WAY AND ANY TEMPORARY OR PERMANENT EASEMENT SHOWN ON THE PLANS. HOWEVER, CONTRACTOR SHALL NOTIFY PROPERTY OWNER(S) FORTY-EIGHT (48) HOURS PRIOR TO WORKING ON ANY PRIVATE PROPERTY TO COORDINATE ACCESS AND TO DETERMINE A STORAGE AREA FOR MATERIALS IF NEEDED. COORDINATION OF ACCESS TO PUBLIC RIGHT-OF-WAY AND STORAGE OF MATERIALS THEREON SHALL BE COORDINATED WITH THE ENGINEER. CONTRACTOR'S FAILURE TO NOTIFY AND COORDINATE WITH PROPERTY OWNERS AND/OR THE ENGINEER MAY RESULT IN DELAYS. NO ADDITIONAL COMPENSATION OR TIME FOR PERFORMANCE WILL BE GIVEN FOR ANYSUCH DELAYS. 4, CONTRACTOR SHALL, AT HIS EXPENSE, MAINTAIN THE WORK SITE IN A CLEAN AND ORDERLY APPEARANCE AT ALL TIMES. ALL DEBRIS AND SURPLUS MATERIAL COLLECTED SHALL BE DISPOSED OF OFF TH E WORK SITE BY CONTRACTOR, AT HIS EXPENSE. 5. EXISTING LAWNS, TREES, SHRUBS, FENCES, UTILITIES, CULVERTS, WALLS, 'vVALKS, DRIVEWAYS„ POLES, SIGNS, RIGHT-OF-WAY MONUMENTS, MAILBOXES AND THE LIKE SHALL BE PROTECTED FROM DAMAGE DURING THE WORK. ANY DAMAGE CAUSED TO SUCH ITEMS SHALL BE REPAIRED OR REPLACED BY CONTRACTOR AT NO ADDITIONAL OOST. PROPERTY PINS DISTURBED BY CONTRACTOR THAT ARE NOT SHOWN ON THE PLANS TO BE DISTURBED SHALL BE RESTORED BY LICENSED SURVEYOR AT THE CONTRACTOR'S EXPENSE. 6. MEASURES TO CONTROL EROSION AND SEDIMENT SHALL BE PROVIDED PURSUANT TO AND IN COMPLIANCE WITH CURRENT FEDERAL, STATE AND LOCAL REGULATIONS. THE INFORMATION CONTAINED I1\1 THE CONSTRUCTION PLANS AND/OR APPROVAL OF THE PLANS SHALL IN NO WAY RELIEVE THE CONTRACTOR OR HIS AGENT OF ANY LEGAL RESPONSIBILITY WHICH MAY BE REQUIRED BY THE CODE OF VIRGINIA OR ANY ORDINANCE ENACTED BY THE CITY OF CHARLOTTESVILL E. CONTRACTOR SHALL PROVIDE THE NECESSARY DIVERSION DITCHES, DIKES, OR TEMPORARY CULVERTS REQUIRED TO PREVENT MUD AND DEBRIS FROM BEING WASHED ONTO THE STREETS OR ADJACENT PROPERTY. CONTRACTOR'S VEHICLES SHALL BE KEPT CLEAN TO PREVENT MUD OR DUST FROM BEING DEPOSITED ON STREETS. NO AREA SHALL BE LEFT DENUDED FOR MORE THAN SEVEN (7) CALENDAR DAYS. 7. CONTRACTOR SHALL CLEAN UP, RESTORE, SEED AND MAINTAIN ALL DISTURBED AREAS IMMEDIATELY UPON COMPLETION OF WORK. TOPSOIL SEED, FERTILIZER AND (MULCH SHALL BE PLACED IN ACCORDANCE WITH ALBEMARL E COUNTY STANDARDS ON ALL DISTURBED AREAS. A PERMANENT STAND OF GRASS ADEQUATE TO PREVENT EROSION SHALL BE ESTABLISHED PRIOR TO FINAL ACCEPTANCE. ALL EROSION AND SEDIMENT CONTROLS SHALL BE REMOVED WITHIN 30 DAYS AFTER THE PROJECT IS STABILIZED. (IIMS-18) 8. FOR FURTHER REQUIREMENTS AND DETAILS OF TREE PRESERVATION, PLANTING, EROSION AND SEDIMENT CONTROL, REFER TO THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. 0. AN EROSION AND SEDIMENT CONTROL CONTRACTOR CERTIFICATION (E.S.C.C.C) IS REQUIRED FOR ALL LAND DISTURBANCE ACTIVITIES. 10. THE CONTRACTOR SHALL PROPERLY INSTALLAND MAINTAIN EROSION AND SEDIMENT CONTROLS FOR THE LIFE OFTHE PROJECT; AND ROUTINELY CHECK CONTROL DEVICES BEFORE, DURING AND AFTER STORM EVENTS. ILM 1. PRIOR TO CONSTRUCTION OR EXCAVATION, THE CONTRACTOR SHALLASSUIME RESPONSIBILITY OF LOCATING ANY AND ALL UNDERGROUND UTILITIES (PUBLIC OR PRIVATE) THAT MAY EXIST WITHIN OR CROSS THROUGH THE AREA OF CONSTRUCTION WHETHER OR NOT THEY ARE SHOWN ON THE PLANS. PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL CALL'IV`IISS UTILITY OF VIRGINIA' AT 1-800-552-7001. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, AT HIS SOLE EXPENSE, ANY EXISTING UTILITY DAMAGED DURING CONSTRUCTION. 2. THE PLAN DOES NOT GUARANTEE THE EXISTENCE, NONEXISTENCE, SIZE, TYPE, LOCATION, ALIGNMENT, OR DEPTH OF ANY OR ALL UNDERGROUND UTILITIES OR OTHER FACILITIES. WHERE SURFACE FEATURES (MANHOLES, CATCH BASINS, VALVES, ETC.) ARE UNAVAILABLE OR INCONCLUSIVE. INFORMATION SHOWN MAY BE FROM UTILITY OWNER'S RECORDS AND/OR ELECTRONIC LINE TRACING, THE RELIABILITY OF WHICH IS UNCERTAIN. THE CONTRACTOR SHALL PERFORM TEST EXCAVATIONS OR OTHER INVESTIGATION AS NECESSARY TO VERIFY LOCATION AND CLEARANCES. 3. WHEN THE WORK CROSSES EXISTING UTILITIES, THE EXISTING UTILITIES SHALL BE ADEQUATELY SUPPORTED AND PROTECTED FROM THE DAMAGE DUE TO THE WORK. ALL METHODS FOR SUPPORTING AND MAINTAINING THE EXISTING UTILITIES SHALL BE APPROVED BY THE RESPECTIVE UTILITY COMPANY AND/OR THE ENGINEER. CONTRACTOR SHALL EXERCISE CARE TO INSURE THAT THE GRADE AND ALIGNMENT OF EXISTING UTILITIES ARE MAINTAINED AND THAT NO JOINTS OR CONNECTIONS ARE DISPLACED. BACKFILL SHALL BE CAREFULLY PLACED AND COMPACTED TO PREVENT FUTURE DAMAGE OR SETTLEMENT TO EXISTING UTILITIES. ANY UTILITIES REMOVED AS PART OF THE WORK, AND NOT INDICATED TO BE REMOVED OR ABANDONED, SHALL BE RESTORED USING MATERIALS AND INSTALLATION EQUAL TO THE UTILITY'S STANDARDS. 4. CONTRACTOR SHALL NOTIFY LANDOWNERS, TENANTS AND THE ENGINEER A MINIMUM OF 72 HOURS PRIOR TO THE INTERRUPTION OF ANY SERVICES. SERVICE INTERRUPTIONS SHALL BE KEPT TO A MINIMUM. 5. CONTRACTOR TO MAKE ANY NECESSARY ADJUSTMENTS TO ALL UTILITY JUNCTION BOXES, VALVE BOXES, MANHOLES, CLEAWOUTS, AND OTHER GRADE RELATED ITEMS IN SIDEWALK, ROADWAY, AND/OR ADJACENT AREAS TO MATCH FINISHED GRADE. COSTS ARE TO BE INCLUDED UNDER THE VARIOUS UNIT BID ITEMS. NO SEPARATE PAYMENT WILL BE MADE. 6. PER THE VIRGINIA DEPARTMENT OF HEALTH WATERWORKS REGULATIONS (PART II, ARTICLE 3, SECTION 12 VAC 5-500 THROUGH 630), ALL BUILDINGS THAT HAVE THE POSSIBILITY OF CONTAMINATING THE POTABLE WATER DISTRIBUTION SYSTEM (HOSPITALS, INDUSTRIAL SITES, BREWERIES, ETC.) SHALL HAVE A BACKFLOW PREVENTION DEVICE INSTALLED WITHIN THE FACILITY. THIS DEVICE SHALL MEET SPECIFICATIONS OF THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE, SHALL BE TESTED IN REGULAR INTERVALS AS 'REQUIRED, AND TEST RESULTS SHALL BE SUBMITTED TO THE REGULATORY COMPLIANCE ADMINISTRATOR IN THE DEPARTMENT OF UTILITIES. 7. ALL BUILDINGS THAT MAY PRODUCE WASTES CONTAINING MORE THAN ONE HUNDRED (100) PARTS PER MILLION OF FATS, OIL, OR GREASE SHALL INSTALLA GREASE TRAP. THE GREASE TRAP SHALL MEET SPECIFICATIONS OF THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE, MAINTAIN RECORDS OF CLEANING AND MAINTENANCE, AND BE INSPECTED ON REGULAR INTERVALS BY THE REGULATORY COMPLIANCE ADMINISTRATOR IN THE DEPARTMENT OF UTILITIES. 8. CONTACT THE REGULATORY COMPLIANCE ADMINISTRATOR AT 9TO-3032 WITH ANY QUESTIONS REGARDING THE GREASE TRAP OR BACKFLOW PREVENTION DEVICES. 0. ALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT EARTH _ l ITS 1. EXCEPT AS OTHERWISE SHOWN ON THE PLANS, ALL CUTS AND FILLS SHALL BE NO GREATER THAN 3:1. 2. UNLESS OTHERWISE NOTED ON THE PLANS OR IN THE SPECIFICATIONS, ALL FILL MATERIALS SHALL BE COMPACTED TO 05% OF THEORETICAL MAXIMUM DENSITY AS DETERMINED BY AASHTO T-00 METHOD A, WITHIN PLUS OR MINUS 2% OF OPTIMUM MOISTURE, FOR THE FULL WIDTH AND THE DEPTH OF THE FI LL . 3. THE CONTRACTOR SHALL ADD, CHANGE, OR RELOCATE EROSION AND SEDIMENT CONTROLS AT THE DIRECTION OF THE ALBEMARLE COUNTY E&S INSPECTOR TO THEIR SATISFACTION AT NO ADDITIONAL COST TO THE OWNER. 4. ALLGRADING AND IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA UNLESS OTHERWISE INDICATED. 5. PROPOSED GRADES SHALL BE FIELD ADJUSTED TO CONFORM TO THE INTENT OF THE TYPICAL SECTIONS. A SMOOTH GRADE SHALL BE MAINTAINED FROM THE BASELINE TO THE PROPOSED EDGE OF PAVEMENT OR FACE OF CURB TO PRECLUDE THE FORMING OF FALSE GUTTERS AND/OR PONDING OF WATER ON ALL PAVED SURFACES. 6. CONTRACTOR SHALL MAINTAIN A SMOOTH GRADE TO THE PROPOSED EDGE OF PAVEMENT OR FACE OF CURB TO PROVIDE POSITIVE DRAINGE ON ALL PAVED SURFACES. ANY AREAS WHERE WATER IS IMPOUNDED SHALL BE CORRECTED BY CONTRACTOR AT NO ADDITIONAL COST. POSITIVE DRAINAGE OF ALL ROADWAYAREAS TO THE STORM DRAIN INLETS OR OTHER ACCEPTABLE DRAINAGE CHANNELS AS NOTED ON THE PLANS IS REQUIRED. 7. CONTRACTOR SHALL MAINTAIN EXISTING STREAMS, DITCHES, DRAINAGE STRUCTURES, CULVERT AND FLOWS AT ALL TIMES DURING THE WORK, CONTRACTOR SHALL PAY FOR ALL PERSONAL INJURY AND PROPERTY DAMAGE WHICH MAY OCCUR AS A RESULT OF FAILING TO MAINTAIN ADEQUATE DRAINAGE. 8. ALL PIPES, DI'S AND OTHER STRUCTURES SHALL BE INSPECTED BY THE ENGINEER BEFORE BEING BACKFILL ED OR BURIED. THE ENGINEER MAY REQUIRE CONTRACTOR, AT NO ADDITIONAL COST, TO UNCOVER AND RE-COVER SUCH STRUCTURES IF THE HAVE BEEN BACKFILLED OR BURIED WITHOUT SUCH INSPECTION. O. ALLSTORM CHANNELS, DRAINS, AND SEWER SYSTEMS SHALL BE CLEANED UPON COMPLETION OFTHE PROPOSED WORK. SEDIMENT, CHEMICALS, AND/OR DEBRIS REMOVED FROM THESE SYSTEMS SHALT_ BE REMOVED AND DISPOSED OF PROPERLY. 10. ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT OVER SIDEWALKS. MA�NTENANU"E 1. TEMPORARY STREET CLOSURE PERMIT REQUIRED FOR CLOSURE OF SIDEWALKS, PARKING SPACES AND ROADWAYS AND IS SUBJECT TO APPROVAL BY THE AL BEMARLE COUNTY TRAFFIC ENGINEER. 2. THE VIRGINIA WORK AREA PROTECTION MANUAL AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) SHALL GOVERN ALL TEMPORARY TRAFFIC CONTROL OPERATIONS THROUGHOUT CONSTRUCTION OF THIS PROJECT. ADHERENCE TO APPLICABLE PROVISIONS OF THE MANUAL IS REQUIRED OFTHE CONTRACTOR EVEN THOUGH DETAILED REFERENCE TO ALL SUCH PROVISIONS MAY NOT BE CONTAINED IN THE PLANS. GENERAL NOTES 3. ALL EXISTING RESIDENTIALAND COMMERCIAL ENTRANCES SHALL BE MAINTAINED AT ALL TIMES, UNLESS OTHERWISE DIRECTED BY THE ENGINEER. 4. NO TEM PORARY PAVEM ENT MARKING SHALL BE ALLOWED ON TH E FINAL ASPHALT SURFACE COURSE. 5. THE CONTRACTOR SHALL MAINTAIN ALL LANES OF TRAVEL OPEN FROM 6:30 AM TO 0:00 AM AND 3:00 PM TO 5:00 PM UNLESS DEEMED UNNECESSARY BY THE ENGINEER. SHORT PERIODS OF ONE WAY FLAGGING OPERATIONS MAY BE CONDUCTED OUTSIDE THE HOURS MENTIONED ABOVE. 6. ALL TRAFFIC SIGNALS SHALL BE ADJUSTED AS DEEMED NECESSARY BY THE ENGINEER PRIOR TO ANY TRAFFIC CHANGES. 7. WHEN WORK IN THE EXCAVATION AREA IS DISCONTINUED FOR A SHORT PERIOD OF TIME, AS AT NIGHT, THE CONTRACTOR SHALL BACKFILL THE CUT AREAS ADJACENT TO THE BUSTING PAVEMENT WITH A'FILLET OF MATERIAU. THE FILLET SHALL BE COMPOSED OF THE SAME MATERIAL (EXCAVATION, BORROW, BASE COURSE, ETC.) ALL COSTS FOR PLACING AND REMOVING THIS FILLET OF MATERIAL SHALL BE INCLUDED IN THE PRICE BID FOR OTHER BID ITEMS OF WORK ON THIS PROJECT, AND NO ADDITIONAL CHARGE WILL BE ALLOWED. 8. EXISTING SURFACE, AGGREGATE BASE AND SUBBASE MATERIAL WHICH WILL BE DEMOLISHED OR OBLITERATED DURING CONSTRUCTION AND WHICH IS SUITABLE FOR MAINTENANCE OF TRAFFIC AS DETERMINED BY THE ENGINEER, SHALL BE SALVAGED AND UTILIZED FOR MAINTENANCE OF TRAFFIC PRIOR TO THE USE OF COMMERCIAL MATERIAL. WHEN NOT SPECIFIED AS A SEPARATE PAY ITEM, THE REMOVAL AND SALVAGING OF EXISTING SURFACES AND AGGREGATE BASE AND SUBBASE MATERIALWILL BE MEASURED AND PAID FOR AS REGULAR EXCAVATION IN ACCORDANCE WITH SECTION 303 OFTHE VDOT ROAD AND BRIDGE SPECIFICATIONS. 0. CONSTRUCT ALL INTERSECTIONS AND DRIVEWAYS UNDER TRAFFIC. 10. IF USED, TEMPORARY TRAFFIC BARRIER SERVICE SHALL BE INSTALLED AND REMOVED SO AS NOT TO PRESENT ANY BLUNT END OR HAZARD TO THE MOTORING PUBLIC. 11. CONTRACTOR SHALL NOTIFY TRANSIT PROVIDERS A MINIMUM OF TWO WEEKS PRIOR TO ANY IMPACT OR DISRUPTION TO REGULAR SERVICE OR STOPS. 12. ALL EXISTING PAVEMENT MARKINGS CONFLICTING WITH PROPOSED CONSTRUCTION PAVEMENT MARKINGS (IF USED) SHALL BE ERADICATED. I-& INSTALLATION AND REMOVAL OF TEMPORARY TRAFFIC CONTROL DEVICES SHALL BE IN ACCORDANCE WITH THE SECTION 6G.25 OF THE WORK AREA PROTECTION MANUAL. 14. USE APPROPRIATE SIGNS TO SHIFT PEDESTRIAN TRAFFIC AS NEEDED. 15. CONTRACTOR SHALL ASSURE ENDS OFTEMPORARY CONCRETE BARRIER (IF USED) DO NOT OBSTRUCT INTERSECTION SIGHT LINES. 1. SMOKING SHALL NOT BE ALLOWED ANYWHERE ON CAMPUS. "NO SMOKING" SIGNS SHALL BE POSTED AT EACH BUILDING SITE AND WITHIN EACH BUILDING DURING CONSTRUCTION PER VIRGINIA STATEWIDE FIRE PREVENTION CODE. 2. OVERHEAD WIRING OR OTHER OVERHEAD OBSTRUCTIONS SHALL NOT BE LOWER THAN 13 FEET 6 INCHES OVER A PUBLIC STREET PER THE VIRGINIA STATEWIDE FIRE PREVENTION CODE. 3. CONTRACTOR SHALL ENSURE THAT BUILDING STREET NUMBERS ARE PLAINLY VISIBLE FROM THE FRONTAGE STREET ATALLTIMES DURING CONSTRUCTION FOR EMERGENCY RESPONDERS, PER VIRGINIA STATEWIDE FIRE PREVENTION CODE. 4. AN APPROVED WATER SUPPLY FOR FIRE PROTECTION SHALL BE MADE AVAILABLE AS SOON AS COMBUSTIBLE MATERIALS ARRIVE ON SITE. WASTE AND COMBUSTIBLE DEBRIS SHALL BE REMOVED FROM THE BUILDING AT THE END OF EACH DAY AND DISPOSED OF IN ACCORDANCE WITH VIRGINIA STATEWIDE FIRE PREVENTION CODE. 5. OPERATIONS INVOLVING THE USE OF CUTTING AND WELDING SHALL BE DONE IN ACCORDANCE WITH CHAPTER 35 OF THE VIRGINIA STATEWIDE FIRE PREVENTION CODE. 6. FIRE EXTINGUISHERS SHALL BE PROVIDED WITH NOT LESS THAW] ONE APPROVED PORTABLE FIRE EXTINGUISHER AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE COMBUSTIBLE MATERIALS HAVE ACCUMULATED IN ACCORDANCE WITH THE VIRGINIA STATEWIDE FIRE PREVENTION CODE. 7. VEHICULAR ACCESS FOR FIRE FIGHTING SHALL BE PROVIDED AT ALL CONSTRUCTION AND DEMOLITION SITES AND TO WITHIN 100 FEET OF TEMPORARY OR PERMANENT FIRE DEPARTMENT CONNECTIONS. VEHICUI AR ACCESS SHALL BE CAPABLE OF SUPPORTING FIRE APPARATUS AND VEHICLE LOADING UNDER ALLWEATHER CONDITIONS IN ACCORDANCE WITH THE VIRGINIA STATEWIDE FIRE PREVENTION CODE. 1. ALL MATERIAL INSIDE FORMS SHALL BE CLEAN AND FREE OF ALL ROCKS AND OTHER LOOSE DEBRIS. SUB -BASE MATERIAL SHALL BE COMPACTED BY MECHANICAL MEANS. 2, CONCRETE SHALL NOT BE PLACED UNLESS THE AIR TEMPERATURE IS AT LEAST 40 DEGREES FAHRENHEIT (F) IN THE SHADE AND RISING. 3. CONCRETE SHALL NOT BE PLACED UNTIL STEEL DOWELS HAVE BEEN INSTALLED IN EXISTING CONCRETE IN ACCORDANCE WITH AI BEMARLE COUNTY STAN DAR DS. 4. 1/2 " PREMOLDED EXPANSION JOINT MATERIAL SHALL BE PLACED AT A MAXIMUM OF 30' INTERVALS ON NEW SIDEWALK, CURB, CURB & GUTTER, AT EACH END OF DRIVEWAY ENTRANCES, AT EACH END OF HANDICAP RAMPS, SOME POINT ON ENTRANCE WALKS AND STEPS ADJUSTMENTS, AND ALONG BUILDINGS AND WALLS WHERE NEW CONCRETE SIDEWALKS ARE PLACED AGAINST THEM. 5. ALL EXISTING CURBS, CURB & GUTTER, SIDEWALK AND STEPS TO BE REMOVED SHALL BE TAKEN OUT TO THE NEAREST JOINT. DEMOLITION AND DISPOSAL COST TO BE INCLUDED IN OTHER UNIT BID ITEMS. NO SEPARATE PAYMENT WILL BE MADE FOR THIS WORK. 6. EXISTING ASPHALT CONCRETE PAVEMENT SHALL BE SAW CUT AND REMOVED AS PER THE SPECIFICATIONS. REMOVAL SHALL BE DONE IN SUCH A MANNER AS TO NOT TEAR, BULGE OR DISPLACE ADJACENT PAVEMENT. EDGES SHALL BE CLEAN AND VERTICAL, ALL CUTS SHALL BE PARALLEL OR PERPENDICULAR TO THE DIRECTION OF TRAFFIC. 7. DISPOSAL OF ALL EXCESS AND DEMOLITION MATERIAL IS THE RESPONSIBILITY OF THE CONTRACTOR. I 1 I ` I- I� - FIM - ( (r TOPOGRAPHY SOURCE: ACTUAL GROUND SURVEY (2005) BASIS OF DATUM: HORIZONTAL: NAD-83 VIRGINIA SOUTH ZONE VERTICAL: NAVD-88 NOTE: THE EXISTING SITE FEATURES SHOWN HEREIN HAVE BEEN FIELD VERIFIED ATTHE TIME OFTHIS APPLICATION. ADDITIONAL SITE FEATURES INSTALLED AFTER THE ORIGINAL SURVEY WAS CONDUCTED HAVE BEEN DEPICTED USING FIELD MEASUREMENTS AND AERIAL PHOTOGRAMMETRIC DIGITIZATION. It �« Ii. II I II � 1. PROTECT ADJACENT AREAS FROM DAMAGE DUE TO CONSTRUCTION ACTIVITIES. 2. INSTALL PERIMETER CONTROL MEASURES AS INDICATED ON PLANS INCLUDING SAFETY FENCE, SILT FENCE, AND TREE PROTECTION. 3. CLEAR AND GRUB EXISTING GROUND COVER AND DEMOLISH EXISTING ITEMS MARKED FOR DEMOLITION. 4. GRADE SITE TO FINAL GRADES PER PLANS. 5. FORM AND INSTALL CONCRETE WORK. 6. STABILIZE ALL AREAS AND REPAIR ANY EROSION AND REMOVE ANY SEDIMENT. 7. INSTALL REMAINING SITE FEATURES. 8. DRESS AND OVERSEED ALL DISTURBED AREAS AS NECESSARY TO AFFECT PERMANENT VEGETATIVE COVER. 9. REMOVE PERIMETER CONTROL MEASURES. WATER 0SET ON ADJACENT PARCEL (FOR REFERENCE i P 015 10 f o'z- 4 N g r s Y >n �I ( y a ( x - ) a i u)) " Lu _Lj of LIU LLI mmz- LiJ LU Lij 4 a al 0A IDANIEL C. HYER Lic. No. 45596 ffi C - Oil AL APPROVED DCH 31 R0i EIC$ 1907100 i