HomeMy WebLinkAboutSDP201800063 Review Comments 2018-09-28 • 0 1111. f 1 MERIDIAN Engineering • Surveying • Planning PLANNING GROUP, LLC 440 Premier Circle,Suite 200 Charlottesville,VA 22901 September 28, 2018 Phone:434-882-0121 www.meridianwbe.co m Chris Perez County of Albemarle 401 McIntire Road Charlottesville, VA 22902 RE: SDP201800063 Hydraulic Road, LLC —Minor Amendment Chris, The following are responses to the comments in letter dated September 19, 2018. I. [Comment] As mentioned in the pre application meetings the site plan shall provide the following notes: a)All waste water into the septic system will be domestic wastes. If this is not the case, a special use permit is necessary. Refer C-001, note added under sanitary service. A.The retail sales area will not exceed 25%of the gross floor area of the main use. Refer to C-001, note added under proposed use. c) This use will not involve outdoor storage and display. V[4.20] Refer to C-001, note added under proposed use. Setbacks. Revise the setbacks as follows: Building Setbacks Front Minimum— 10' Front Maximum—None Side Minimum—50' from the RA district boundary Refer to C-001, updated notes under building setbacks. Parking Setbacks Front Minimum— 10' Side Minimum—30' from the RA district boundary Refe to C-001, updated notes under parking setbacks. 3. .16] Parking. On the plans label which parking spaces are for customers. Refer to C-201, customer parking called out. r ; 1111) 4. [32.7.9] Landscaping. Provide a complete landscape plan. Depict where the next plantings will be(at a minimum cover all replacement plantings for the plantings being removed and all ARB plantings). Refer to sheet C-301 for landscaping plan. 5. [Comment] On the cover sheet provide the following"SDP2018-63 Minor Amendment". Refer to C-001 for title. 6. omment] On the cover sheet the plan references "Water Service: Existing Well"; however, the proposal is to connect to public water. Thus this note shall be revised to state "Water Service:Public Water." Refer to C-001,water service information revised. 7. Comment] Sheet 1 lists TMP parcel as 61 W-5A-1 in the depiction; however, it truly is TMP 61-5A-1. Revise. Refer to C-001,TMP revised. [Comment] VDH approval is required prior to County approval of the site plan amendment. Comments pending to be forwarded once received. Comment noted. Engineering—John Anderson CV comments: 1. "DB-PG reference for Ex. Private Access Easement, BK 4834, PG 123, does not appear to match Circuit Court Land records (Property Power of Attorney; a different parcel). Please confirm DB-PG reference for Ex. Pvt. Access Easement is accurate. Refer to C-201 for revised deed book reference. 2. Proposed addition of a 1-story addition to existing structure on TMP 06100-00-00-005A1 with land disturbance of 4,049 SF, is not subject to the VESCP (17-300), or the VSMP(17-302). Note: a WPO Plan and Application are not required. A SWPPP is not required. Comment Noted 3. C-001 lists TMP parcel as 61 W-5A-1, which does not appear to match County GIS real estate records. Please confirm,and revise plan as necessary to reflect correct TMP information. Refer to C-001,TMP updated. 4. Note: Proposed permeable pavers are optional. County design review is not required. Comment Noted. 5. Note: Any change to existing entrance on Hydraulic Road should be coordinated with VDOT through the current MIA review for Albemarle Countertop Company. VDOT will likely require a land use permit, and may require temporary lane closure, and work area protective measures." Comment Noted. ACSA—Richard Nelson 1. Include ACSA specification details for fire hydrant assembly and water meter. Refer to 6/C-202 and 7/C-202, for details. 2. Provide fixture counts to determine water meter size. Refer to 5/C-202 for fixture counts. • 3.The fire hydrant will be moved back—6-feet, a I6'x20' easement will be required. Refer to 4/C-202 for location of easement. Building Inspection—Mike Dellinger 1. Retaining walls greater than 3 feet in height require a separate building permit. Walls exceeding 4 feet in height require a stamped engineered design also. None proposed. 2. Parking spaces and access isles shall not have a surface slope greater than 1:48. Access isles shall be at the same level as the parking space they serve. Refer to C-201, all slopes are less than 1:48. Fire and Rescue—Shawn Maddox 1. If the building will become sprinklered a fire department connection shall be shown on the plans and located within 100'of a hydrant arranged in a manner that will not obstruct traffic flow. Comment noted. 2. A knox box will be required. Please place a note on the plans indicating this requirement and that the location can be coordinated with the fire marshal's office. . Refer to C-201, Knox box note added. VDOT—Adam Moore No objection(comments attached) None. ARB-Margaret Maliszewski Comments attached. None. Please let me know if you need any additional information. Sincerely, • Timothy Miller, P.E., L.S. Principal