HomeMy WebLinkAboutSDP201800084 Review Comments 2019-08-08 Christopher Perez
From: Christopher Perez
Sent: Thursday, August 08, 2019 4:22 PM
To: William M. Eschenfelder
Subject: SDP201800084 Parking Lot and Apron Expansion - Minor Amendment
Bill,
RE: SDP201800084 Parking Lot and Apron Expansion-Minor Amendment
I received your voicemail seeking a status update. I plan to finish up my review of the plan sometime next week,aside
from that I am waiting on ARB's review,they also hope to have it completed sometime next week.
In the meantime, I offer the following reviewer comments(please don't make any changes till you receive all review
comments).thanks
Michael Dellinger—Building Inspections(comments provided below)
1.Add the following note to the general notes page:
Retaining walls greater than 3 feet in height require a separate building permit. Walls exceeding 4 feet in height require
a stamped engineered design also. Walls require inspections as outlined in the USBC.
2.Add the following note to the general notes page:
Accessible parking spaces and access isles shall not have a surface slope greater than 1:48.Access isles shall be at the
same level as the parking space they serve.
3.Add the following note to the general notes page:
ALL water lines, sewer lines, and fire lines from the main to the structure MUST have a visual inspection performed by
the building department.
4.Add the following to the general notes page:
All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks.
Matthew Wentland—Engineering
1.No objection
Christopher Perez I Senior Planner
Department of Community Development'County of Albemarle,Virginia
401 McIntire Road I Charlottesville,VA 22902
434.296.5832 ext.3443
1