HomeMy WebLinkAboutZMA197900031 Review Comments Zoning Map Amendment 1979-10-10OF ALSEM
h8c111��
Department of Planning
2OBERT W. `DUCKER, .JR. 804/296-5823 RONALD S. KEELER
(DIRECTOR OR PLANNING 414 EAST MARKET STREET ASSISTANT DIRECTOR OF PLANNING
CHARLOTTESVILLE. VIRGINIA 22901 DOUGLAS W. ECKEL
SENIOR PLANNER
September 10, 1979 NANCY MASON CAPERTON
PLANNER
IDETTE CHARLIE KIMSEY
PLANNER
Mr. Max Evans
c/o Twin Group
2200 Old Ivy Road
Charlottesville, Virginia Re: ZMA-79-31. Twin Group RPN
Dear Mr. Evans,
The Site Plan Review Committee reviewed the above referenced plan on
September 6, 1979. Enclosed are copies of the comments from the site review
committee members. Also enclosed is a RPN checklist which must be completed and
returned to me. Please send me five additional copies of the plan along with
the checklist.
Please call me if you have any questions.
Sincerely,
C
N. Mason Caperton
Planner
NMC:jc
N.�.` OF ALSE,y
OF A
Office of County Engineer
414 EAST MARKET STREET
CHARLOTTESVILLE, VIRGINIA 22901
J. HARVEY BAILEY
COUNTY ENGINEER J. ASHLEY WILLIAMS
ASSISTANT COUNTY ENGINEER
MEMO
TO: Mason Caperton, Planner
FROM: J. Ashley Williams, Assistant County Engineer t
RE: Site Plan Review - Jessup Property R,P.N,
DATE: September 7, 1979
My only comments are the development of this site will require a soil erosion
and sedimentation control plan and the review of the road plans by this office.
qordon ti'a9¢r
Page 2 , S. ��
( ►ns�r�afi.dr> Oeru i cc
14- Richard Debutts Final Plat - No comment
15- Gardner Final Plat- No comment
1- Birckhead Guest Cottage - No particular soil problem except slopes
and erosion control.
2- Robert L. Beverly - No comment
3- Everingham Blake Final Plat - No particular soil problems except
erosion control and steep slopes.
4- Redbud Prelimina Plat - Some of this
x'y parcel is located on steep
slopes which could cause erosion problems. Depth to bedrock could be
E-
a problem in some areas.
5- North Pines Final Plat -'This parcel consists of a variety of soil types, "
for the most part soils appear favorable. however, there are areas of
shallow soil on steep slopes which will make road, house and septic
drainfield locations critical.
6- Coleman Estate Final Plat- No comment..
7- Grymen/Thomas Jefferson Memorial Foundation - No comment.
g
a
8- Le Beau Sol Final Plat - Soils on this parcel consist of Eayesville
clay loam, Chester silt loam and Dyke loam. There should be no unusual
soil problems.
9- Rutledge Farm - There should be no unusual soils problems except
control on steep slopes.
10- Wynridge, Phase 2, Final Plat - There should be no unusual soil
problems except storm water runoff and erosion control.
11- Church of the Incarnation - No particular soil problems except erosion control
12- Crozat Baptist Church- No comment.
-�3-- ZMA-79-31-Twin Graup RPN (Jessup Property) - There should be no unusual
soil problems except steep slopes will require that erosion control measurers
be installed properly. Proper house and septic drainfield locations will also
be important to minimize grading requirements.
14- ZMA-79-32 Briarwood RPN - There should be no unusual soil problems except
erosion control. Excessive grading will require erosion control measures
be installed promptly and properly.
15- Carlton Luck Final Plat- No comment.
1. Birckhead Guest Cottage Site Plan - septic tank has been issued.
2. Robert L. Beverly Final Plat - will need health dept. approval.
3. Everingham Blake Final Plat - will need health dept. approval.
4. Redbud Preliminary Plat - will need health dept. approval.
5. North Pines Final Plat - will need health dept. approval.
6. Coleman Estate Final Plat - will need health dept. approval.
7. Grymes/Thomas Jefferson Memorial Foundation Final Plat - will
need health dept. approval.
8. Le Beau Sol Final Plat - will need health dept. approval.
9. Rutledge Farm Preliminary Plat - will need health dept. approval.
10. Wynridge, Phase 2, Final Plat - public water and sewer.
11. Church of the Incarnation Site Plan - has public water and
sewer available.
12. Crozet Baptist Church Site Plan Addition - will need health
dept. approval.
30 ZMA-79-31 - Twin Group RPN (Jessup Property) - will need
health dept. approval.
14. ZMA-79-32 - Briarwood RPN - will have public water and sewer.
15. Carlton Luck Final Plat - will need health dept. approval.
Mason Caperton
Site Plans
PAGE II
Ulf `
12. Crozet Baptist Church - Provide handicapped facilities; hydrants required
within 400 feet of the 9000 square foot addition.
ZMA 79-31 Twin Group - Hydrants to be located every 800 feet along
roadway; 750 GPM at 20 PSI; 22 inch C&0 thread.
14. Briarwood RPN - Hydrants required every 800 feet along roadway; 750 GPM at
20 PSI; 22 inch C&0 thread.
15. Carlton Luck - No comment
IBC/lt
County of Albemarle
Page -2-
September 7, 1979���-`
6A) Coleman Estate Final Plat, off Route 631 South: Adequate sight dis-
tance exists for a commercial entrance. The design of that entrance needs to be im-
proved.
7A) Grymes/Thomas Jefferson Memorial Foundation Final Plat, Route 53:
Adequate sight distance exist for a private entrance.
8A) Le Beau Sol Final Plat, Route 637 and Route 750: Adequate sight
distance exist for a private entrance to all lots. We would recommend frontage im-
provements to Route 637 along its entire length placing the shoulder catch point at
15 feet from the existing center of road and the ditch at 18 feet. We would recom-
mend frontage improvements to Route 750 from the property corner of Lot 4/5, west '
toward the intersection of Route 637, placing the shoulder catch point at 15 feet,
and ditch where necessary at 18 feet from the center of the existing road,
9A) Rutledge Farm Preliminary Plat, Route 743: It appears that sight
distance is adquate for a commercial entrance may be obtainable provided permission
can be obtained to clear vegetation to the south of this property and with some
minor regrading to Route 743 to the north. Due to the orientation of traffic, a
left turn lane would be more desirable than a right turn deceleration lane. This
may, however require right of way along more frontage than the developer contrcl.s.
That is; to the south of the entrance. Accordingly, we request that the alignment
of Route 743 be projected south of this property approximately 1,000 feet from the
proposed entrance location.
10A) Wynridge, extention of Westfield Road, Route 1452: Extention of
Westfield Road needs to be covered through a set of road plans. The intersection
with Westfield Road and future road to Section II of Wynridge needs to be examined.
Minimum radius for thru streets is 215 feet. A thru street is one which has other
streets along its length. Neither of the two cul-de-sac, Lots 62/67 and I.ot 68/72
meet Department standards. A street before the cul-de-sac radius must be a minimum
of one lot deep. Lot line 62/63 and 67/66 are the center of the cul-de-sac. Lot,
line 68/69 and 71/72 are beyond the center of the cul-de-sac. Road plans, geome-
tries, grades and necessary drainage easements will be checked as road plans are
developed.
11A) Church of the Incarnation Site Plan, off Route 29 North,(Branch-
lands): The existing entrance is adequate at this time.
12A) Crozet Baptist Church Site Plan, St George Avenue, Route 1203:
Standard design commercial entrance will be required. A minimum of 25 feet is
needed between commercial entrances. It appears that the parking area east of
St. George Avenue is sloped toward the road. A drainage pickup may be needed to
direct this water to an appropriate outlet. It appears that entrance curb is
shown extending to the edge of St. George Avenue pavement. This curb must stop
a minimum of 8 feet from the edge of pavement. This however, is a detail which
can be corrected at the permit stage.
' 13A) ZMA-70 31, Jes^up Property, Route 654: Our comments concerning
the need for a left turn lane rom in in effect from the previous site plan. The
design of that turn lane would also be the same
Mason Caperton
September 5, 1979
Page 3
-1 Birckhead Guest Cottage Site Plan: Public water is available; sewer is
not.
2. Robert L. Beverly Final Plat: No public facilities are available.
3. Everingham Blake Final Plat: No public facilities are available.
4. Redbud Preliminary Plat: No public facilities are available.
5. North Pines Final Plat: Public facilities are available; water and
sewer construction plans will be required. It appears that this
development would require an expansion of the Sewage Treatment Plant.
This expansion must be approved by the Board of Supervisors.
6. Coleman Estate Final Plat: No public facilities are available.
7. Grymes/Thomas Jefferson Memorial Foundation Final Plat: No public
facilities are available.
8. Le Beau Sol Final Plat: No public facilities are available.
9. Rutledge Farm Preliminary Plat: No public facilities are available.
10. Wynridge, Phase 2, Final Plat: Public facilities are available.
11. Church of the Incarnation Site Plan: Public facilities are available.
12. Crozet Baptist Church Site Plan Addition: Public water is available;
sewer is not.
11. ZMA-79-31-Twin Group RPN (Jessup Property): Public water is available.
A detailed set of construction plans will be required. A more detailed
-set of plans will be required showing the elevations of sewer manhole
invert at Old Salem Apartments before sewer availability can be
determined.
14. ZMA-79-32-Briarwood RPN: Public facilities are available. A detailed
set of construction plans will be required. It appears that this
development would require an expansion of the Sewage Treatment Plant.
This expansion must be approved by the Board of Supervisors.
15. Carlton Luck Final Plat: No public facilities are available.
BPS/dr
71a.-79- 3l - Tv. i n G.rollp RPN Property) - Located on the soot
of Rt. 651 (Barracks Rd.) about 2 miles northwest of the Rarracks� Road shop-
ping Center; proposal to rczane 16.0 acres from A-1 to RP14/RS-1 with 10 lots
and 6.12 acres in open space; Samuel Miller District.
Name of
misting or
School
Projected
Planned
School
Capacity
Enrollment
Improvements
Enrollment
,((
Within the
Sept. 1979
�1
Next 5 Years
'lntary uLce�
550
800
8
None
:ntermediate�
625
830 #
None
'��ry 4�
##
/A
2030
2305
��
None
.ompletion Date or Estimated Phasing:
Additional Ccnnents:
The impact of this projected enrollment will be slight. Note,
however, that both the middle and secondary schools require the use
of mobile classrooms in order to house the programs offered the
current, under capacity, enrollment.
John W. Massie, J
Administrative Assistant
to the Superintendent
8-29-79
# Including 2 small mobile classrooms.
## Including 5 large mobile classrooms and allowance for the attendance
at CATEC of approximately 90 students (FTE).