Reviewer: Frank Pohl tv; CDD Engineering Requested Changes
-Change'riparian buffer'to 'stream buffer'-Albemarle County does not use the term'riparian°. ..
-Revise hatching for 35 ft stream buffer to start at the top of bank, similar to the original plan_Add the critical slopes hatch back
to the plan_
-Add a note on the plan that the 35-ft buffer will not be disturbed and will be protected under an easement I am concerned that
the buffer will be forgotten about many years from now.
-Parking area improvements are not exempt from VSMP permitting requirements unless the area of land disturbance is less
than 10,000 sf[17-303]. Previous plan did not show parking within the County limits_
-Construction of the parking area is not exempt from floodplain permitting requirements, regardless of the area disturbed [18-
30.3.12]. Previous plan did not show parking within the County limits.
-Accessory structures are allowed by-right in the floodplain but shall a floodplain development permit is required for these
structures [18-30.3.12]_Accessory structures shall not exceed 200 sf[18-30.3.5] unless a variance is approved [18-30.3.17].
Accessory structures constructed within the floodplain shall be constructed in accordance with the floodplain Construction
Standards [18-30.3.15].Applicant shall confirm with building official if sheds can be connectedlattached as shown on the
Conceptual Plan dated 01116118_ Previous plan did not show the'farm sheds'within County limits_
•