HomeMy WebLinkAboutZMA201700007 Review Comments 2018-01-18 Review Comment: =�r ZMA201700007 Project Name: HOGWALLER FARM—ZMA Date Completed: Thursday, January 18, 2018 Department/Division/Agency: Review Status: Reviewer: Frank Pohl tv; CDD Engineering Requested Changes -Change'riparian buffer'to 'stream buffer'-Albemarle County does not use the term'riparian°. .. -Revise hatching for 35 ft stream buffer to start at the top of bank, similar to the original plan_Add the critical slopes hatch back to the plan_ -Add a note on the plan that the 35-ft buffer will not be disturbed and will be protected under an easement I am concerned that the buffer will be forgotten about many years from now. -Parking area improvements are not exempt from VSMP permitting requirements unless the area of land disturbance is less than 10,000 sf[17-303]. Previous plan did not show parking within the County limits_ -Construction of the parking area is not exempt from floodplain permitting requirements, regardless of the area disturbed [18- 30.3.12]. Previous plan did not show parking within the County limits. -Accessory structures are allowed by-right in the floodplain but shall a floodplain development permit is required for these structures [18-30.3.12]_Accessory structures shall not exceed 200 sf[18-30.3.5] unless a variance is approved [18-30.3.17]. Accessory structures constructed within the floodplain shall be constructed in accordance with the floodplain Construction Standards [18-30.3.15].Applicant shall confirm with building official if sheds can be connectedlattached as shown on the Conceptual Plan dated 01116118_ Previous plan did not show the'farm sheds'within County limits_ • Page: 11 County of Albemarle Printed On: 1011312018