Loading...
HomeMy WebLinkAboutARB201900105 Sign - Drawings 2019-10-25Branding Package Store 17626 314 Rolkin Rd. Charlottesville, VA 22911 Standard CIMCI building brands together BUILDING ELEVATIONS DRIVE THRU DRIVE THRU CANOPY DAMAGE Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. DAMAGED DIRECTIONAL '�uu .0 - rlt FASCIA DAMAGE & DISCOLORATION All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. DWg By: CMC This includes ro er roundin and bonding of the sign. Date: 1.24.19 P P I 9 9 9 9 Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 3 120'-0" PROPOSED Circa Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for your exclusive review, in connection with a project being proposed by Cimo Network, Inc. it is 121 New Britain Blvd. fax: 267.308.0577 not to be shown to anyone outside your organization, nor isittobeused, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in any foshion without the expressed constentofCimoNetwork, Inc. FRONT•ELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE •• EXISTING: 65.0 SQ FT PROPOSED: 82.2 SQ FT ALLOWED: 100.0 SQ FT Total For Building ----------------—— — ----t ---------------------, ------------ -i--� - -- - - - C _ -,--i- I All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes ro er roundin and ofthe n. Date: 1.24.19 P I P 9 9 9 9 Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 EV R0 160'-0" EXISTING PROPOSED Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. RIGHT •ELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE •• EXISTING: 65.0 SQ FT PROPOSED: 82.2 SQ FT ALLOWED: 180 SQ FT Total For Building It -----------i------------, --—— — — — — — — I W- ----------, I I j I I i I I CENTER SIGN IN AVAILABLE AREA ------------, ------------- L ------------ J CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. DWg By: CIVIC This includes ro er roundin and bonding of the sign. Date: 1.24.19 P P I 9 9 9 9 Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 5 EXISTING �' . di . -n PROPOSED Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the DW B : CIVIC Electrical Code and/or other applicable local codes. g y This includes propergrounding and bonding ofthe sign. I Date: 1.24.19 LEFT •RELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE •• EXISTING: 65.0 SQ FT PROPOSED: 00.0 SQ FT ALLOWED: 180 SQ FT Total For Building Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 6 c1ma � 18'-41/8" Dja]oft 18' 4-1/4" ILLUMINATED CHANNEL LETTERS 7 SCALE: 3/8" = TO" (2) REQ'D PF2 PF3 PH 5" rF== 12 I II II 9 10 © DETAIL @ WALGREENS 7 SCALE: 1-1/2" = 1' 0" Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cimo Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. 5" 111 It ------------------------1 I --- ; I I I I -Me -- ---- SIDE VIEW CENTER SIGN IN AVAILABLE AREA 7 SCALE: 3/8" = 1' o" DETAIL @ ANGLE CLIP 7 SCALE: HALF SIZE COLORS & FINISHES PF1.E FACE: #2793 Red Acrylic Face (PMS 187C) PF2.E RETURNS: Pre -finished Hunter Red (PMS 187C) PF3.ETRIM CAP: Pre -finished True Red (PMS 187C) SIGN CONSTRUCTION 1. RETURNS: 040" Pre -finished Aluminum Returns Stapled/Pop Riveted To Backs 2. TRIM CAP: 1" Wide w/ #8 X 1/2" Long Pan Head Screws Painted To Match 3. FACES:.177" Thick #2793 Red Acrylic. 4. BACKS:.063 Thick Routed Aluminum 5. DRAIN HOLES: (3) 1/4"0 Per Letter. One Must Be As Close To Back As Possible ELECTRICAL (SIGN TO BE UL LISTED) 6. LEDS: Sloan Prism Red 7. WIRE: Secondary Low Voltage Led Wire 8. PASS THRU: Paige Wallbuster Or Approved Equal. 9. POWER SUPPLY: Sloan 60C1 60 Watt 12VDC Class 2 Power Supply Inside Enclosure. 10. ENCLOSURE: Paige Box Or Approved Equal 11. PRIMARY:1/2" Conduit To Disconnect Switch Secure To Wall w/Straps By Others 12. SERVICE SWITCH: Located On End Of Enclosure INSTALLATION HARDWARE Threaded Rod Will Be Provided Standard. All Other Hardware Is to Be Provided By Installer As Required. 13. RIV-NUTS: 1/4-20. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 14. ANGLE CLIPS:1/8" x 1-1/2" x 1-1/2" Aluminum. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 15. HARDWARE: Min. 1/4"0 Non -corrosive Hardware. (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Sections BUILDING & FASCIA CONDITIONS 16. WALL SURFACE: Varies CHANNEL LETTER INSTALLATION NOTES: 1. Sufficient Primary Dedicated Circuit Within 5' Of Center Of Sign By Others. 2. Final Primary Hook-up By Sign Installer Where Allowed By Local Codes. 3. All Visible Wiring & Conduit To Be Run In Straight Lines & 90' Bends. 4. Seal All Building Penetrations. 5. Mounting Hardware By Sign Installer Unless Otherwise Noted. TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITION SIZE, LOCATION AND QTY NOTED ON DWG SEAL ALL BUILDING PENETRATIONS THRU BOLT RIV-NUTS WITH ALL -THREAD. UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8" ALUM ANGLE SLEEPERS SPANNING MIN (2) STRUCTURAL WALL MEMBERf ANTI -CRUSH SPACERS AS REQ'D FOR LAG BOLT LAG BOLT INTO MIN 3/4" PLYWOOD. (FHREADS MUST PASS THRU PLYWOOD). ANTI -CRUSH SPACERS AS REQ'D FOR EIFS OR HOLLOW FASCIA EXPANSION ANCHOR EXPANSION ANCHOR INTO SOLID CONCRETE OR GROUT FILLED MASONRY 1-1/4" MIN EMBEDMENT (NOT FOR HOLLOW MASONRY) **ALL HARDWARE MUST BE NON -CORROSIVE** All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the DW B : CMC National Electrical Code and/or other applicable local codes. g y This includes proper grounding and bonding of the sign. Date: 1.24.19 P P 9 9 9 9 I EST. ELECTRICAL LOAD (1.4) Amps @120 Volts ELECTRICAL REQUIREMENTS (1) 20 Amp/120 Volt Circuits ESTIMATED WEIGHT 138 lbs. Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 7 7'-4 3/4" P__HARMACY ®0ft 12" ILLUMINATED CHANNEL LETTERS 8 SCALE: 3/4" = 1' 0" (2) REQ'D AM DETAIL @ PHARMACY 8 SCALE: 1-1/2" = V 0" oft SIDE VIEW 8 SCALE: 3/8" = 1' 0. Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. ------------- - L PH A R N %-- - C Y_ -, I— — — — — — — — — — — — — ------------ CENTER SIGN IN AVAILABLE AREA TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITION SIZE, LOCATION AND QTY NOTED ON DWG SEAL ALL BUILDING PENETRATIONS THRU BOLT RIV-NUTS WITH ALL -THREAD. UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8" ALUM ANGLE SLEEPERS SPANNING MIN (2) STRUCTURAL WALL MEMBER: ANTI -CRUSH SPACERS AS REQ'D FOR LAG BOLT LAG BOLT INTO MIN 3/4" PLYWOOD. (THREADS MUST PASS THRU PLYWOOD). ANTI -CRUSH SPACERS AS REQo FOR EIFS OR HOLLOW FASCIA EXPANSION ANCHOR EXPANSION ANCHOR INTO SOLID CONCRETE OR GROUT FILLED MASONRY. 1-1/4" MIN EMBEDMENT (NOT FOR HOLLOW MASONRY) **ALL HARDWARE MUST BE NON -CORROSIVE** All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes ro er roundin and bonding of the sign. Date: 1.24.19 P P I 9 9 9 9 COLORS & FINISHES PF1.E FACE: #2793 Red Acrylic Face (PMS 187C) PF2.E RETURNS: Pre -finished Hunter Red (PMS 187C) PF3.ETRIM CAP: Pre -finished True Red (PMS 187C) SIGN CONSTRUCTION 1. RETURNS: 040" Pre -finished Aluminum Returns Stapled/Pop Riveted To Backs 2. TRIM CAP: 1" Wide w/ #8 X 1/2" Long Pan Head Screws Painted To Match 3. FACES:.177" Thick #2793 Red Acrylic. 4. BACKS:.063 Thick Routed Aluminum 5. DRAIN HOLES: (3) 1/4"0 Per Letter. One Must Be As Close To Back As Possible ELECTRICAL (SIGN TO BE UL LISTED) 6. LEOS: Sloan Prism Red 7. WIRE: Secondary Low Voltage Led Wire 8. PASS THRU: Paige Wallbuster Or Approved Equal. 9. POWER SUPPLY: Sloan 60C1 60 Watt 12VDC Class 2 Power Supply Inside Enclosure. 10. ENCLOSURE: Transformer Box By Installer 11. PRIMARY: 1/2" Conduit To Disconnect Switch Secure To Wall w/Straps By Others 12. SERVICE SWITCH: Located On Enclosure INSTALLATION HARDWARE Threaded Rod Will Be Provided Standard. All Other Hardware Is to Be Provided By Installer As Required. 13. RIV-NUTS: 1/4-20. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 14. ANGLE CLIPS: 1/8" x 1-1/2" x 1-1/2" Aluminum. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 15. HARDWARE: Min. 1/4"0 Non -corrosive Hardware. (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Sections BUILDING & FASCIA CONDITIONS 16. WALL SURFACE: Varies CHANNEL LETTER INSTALLATION NOTES: 1. Sufficient Primary Dedicated Circuit Within 5' Of Center Of Sign By Others. 2. Final Primary Hook-up By Sign Installer Where Allowed By Local Codes. 3. All Visible Wiring & Conduit To Be Run In Straight Lines & 90' Bends. 4. Seal All Building Penetrations. 5. Mounting Hardware By Sign Installer Unless Otherwise Noted. Design approval RFI number (#2069) EST. ELECTRICAL LOAD (2.0) Amps 9120 Volts ELECTRICAL REQUIREMENTS (1) 20 Amp/120 Volt Circuits ESTIMATED WEIGHT 50 lbs. Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 8 4r'a • EXISTING PROPOSED 12" Channel Letters (8 sq ft) Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. REAR •RELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE • • EXISTING: 9.0 SQ FT PROPOSED: 9.7 SQ FT ALLOWED: 100.0 SQ FT Total For Building i r-----------------------t - - - D-RI V ETHRU 1- 1 CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meet the requirements of Client: Walgreens Job#: 7405 Store#: 71626 UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. DWg By: CIVIC Address: 314 Rolkin Rd. This includes propergrounding and bonding ofthe sign. I Date: 1.24.19 Charlottesville, VA 22911 REV 10.21.19 10 DRIVE THRU 0 12" ILLUMINATED DRIVE THRU CHANNEL LETTERS 10 SCALE: 3/4" = 1' 0" (1) REQ'D 1 SCALE,1-1/2" = 1' 0" Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. 5" SIDE VIEW 10 SCALE: 3/4" = TO" ------------------------1 r-------------------i I - - -DRVE -THRU - I I i I I CENTER SIGN IN AVAILABLE AREA COLORS & FINISHES PF1.E FACE: #2793 Red Acrylic Face (PMS 187C) PF2.E RETURNS: Pre -finished Hunter Red (PMS 187C) PF3.ETRIM CAP: Pre -finished True Red (PMS 187C) SIGN CONSTRUCTION 1. RETURNS: 040" Pre -finished Aluminum Returns Stapled To Backs 2. TRIM CAP: 1" Wide w/ #8 X 1/2" Long Pan Head Screws Painted To Match 3. FACES:.177" Thick #2793 Red Acrylic. 4. BACKS: 3mm Thick Routed ACM Stapled To Returns 5. DRAIN HOLES: (3) 1/4"0 Per Letter. One Must Be As Close To Back As Possible ELECTRICAL (SIGN TO BE UL LISTED) 6. LEOS: Sloan Prism Red 7. WIRE: Secondary Low Voltage Led Wire 8. PASS THRU: Paige Wallbuster Or Approved Equal. 9. POWER SUPPLY: Class 2 Power Supply Inside Enclosure. 10. ENCLOSURE: Transformer Box By Installer 11. PRIMARY: 1/2" Conduit To Disconnect Switch Secure To Wall w/Straps By Others 12. SERVICE SWITCH: Located In Junction Box By Others INSTALLATION HARDWARE Threaded Rod Will Be Provided Standard. All Other Hardware Is to Be Provided By Installer As Required. 13. RIV-NUTS: 1/4-20. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 14. ANGLE CLIPS: 1/8" x 1-1/2" x 1-1/2" Aluminum. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 15. HARDWARE: Min. 1/4"0 Non -corrosive Hardware. (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Sections BUILDING & FASCIA CONDITIONS 17. WALL SURFACE: Varies CHANNEL LETTER INSTALLATION NOTES: 1. Sufficient Primary Dedicated Circuit Within 5' Of Center Of Sign By Others. 2. Final Primary Hook-up By Sign Installer Where Allowed By Local Codes, 3. All Visible Wiring & Conduit To Be Run In Straight Lines & 90' Bends. 4. Seal All Building Penetrations. 5. Mounting Hardware By Sign Installer Unless Otherwise Noted. TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITION SIZE, LOCATION AND QTY NOTED ON DWG SEAL ALL BUILDING PENETRATIONS THRU BOLT RIV-NUTS WITH ALL -THREAD. UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8" ALUM ANGLE SLEEPERS SPANNING MIN (2) STRUCTURAL WALL MEMBERf ANTI -CRUSH SPACERS AS REQ'D FOR LAG BOLT LAG BOLT INTO MIN 3/4" PLYWOOD. (THREADS MUST PASS THRU PLYWOOD). ANTI -CRUSH SPACERS AS REQ'D FOR EIFS OR HOLLOW FASCIA EXPANSION ANCHOR EXPANSION ANCHOR INTO SOLID CONCRETE OR GROUT FILLED MASONRY 1-1/4" MIN EMBEDMENT (NOT FOR HOLLOW MASONRY) **ALL HARDWARE MUST BE NON -CORROSIVE** All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes ro er roundin and bonding of the sign. Date: 1.24.19 P P I 9 9 9 9 EST. ELECTRICAL LOAD (2.0) Amps @120 Volts ELECTRICAL REQUIREMENTS (1) 20 Amp/120 Volt Circuits ESTIMATED WEIGHT 50 lbs. Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 10 dl=- is • EXISTING PROPOSED Clearance Plaque (1.67 sq ft) Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a project being proposed by Cima Network, Inc. if is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com orexhibited in any fashion without the expressed constentofCima Network, Inc. REAR ••ELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations SQUARESIGNAGE •• EXISTING: 9.0 SID FT PROPOSED: 9.7 SID FT ALLOWED: 100.0 SID FT Total For Building -----------------------, I i � I I i I ----------I CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meet the requirements of Client: Walgreens Job#: 7405 Store#: 71626 UI 48 and installed to meetthe requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CNIC Address: 314 Rolkin Rd. This includes proper grounding and bonding ofthesign. I Date: 1.24.19 Charlottesville, VA 22911 REV 10.21.19 10 12" 4'-0" 2-0" � 0 8'-0" CLEARANCE. NON ILLUMINATED CLEARANCE PLAQUE 12 SCALE: 1-1/2" = V 0" (1) REQ'D l i l ----------I ------------i-- CENTER SIGN IN AVAILABLE AREA © DETAIL -WALL MOUNT 1 SCALE: 1-1/2" = V 0" Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. 12" O 1" From Back Of Sign © DETAIL - HANGING MOUNT 1 SCALE: 1-1/2" = 1' 0" All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC This includes ro er roundin and bonding of the sign. Date: 1.24.19 P P I 9 9 9 9 DESCRIPTION Exterior Canopy Clearance Plaque. Sign To Be Fabricated As Wall Or Hanging Mount. COLORS & FINISHES V1.❑VINYL: 3M 580-71 Reflective Yellow (PMS 136C) V2.0VINYL: 3M 3630-22 Black (PMS Black 6C) P1.❑ PAINT: Edges To Match 3M 580-71 Reflective Yellow (PMS 136C) SIGN CONSTRUCTION 1. SIGN PANEL: 1/8" Flat Aluminum w/ 1 st Surface Vinyl & Edges Painted To Match Vinyl. 2. HOLES: (4) 3/16"0 - (1) In Each Corner For Wall Mount Hardware 3. HOLES: (2) 1/4"0 In Top For Hanging Hardware INSTALLATION HARDWARE 4. HARDWARE: Minimum #10 Non -Corrosive Hardware To Suit Wall Conditions. Min. (4) Per Sign Panel 5. HARDWARE: (2) 3/16"0 Non -Corrosive "S" Hooks For Hanging Mounting MOUNTING CONDITIONS 6. WALL SURFACE: Varies 7. WALL SIGN: Eye Hooks In Bottom Of Sign 1" From Back NOTES: 1. Fab With (6) Mounting Holes Through Aluminum For Wall Or Hanging Mount 2. Do Not Cut Holes Through Reflective Yellow Vinyl Until Time Of Installation. Only Cut Holes Through Vinyl That Are Required For Type Of Installation Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 12 EXISTING PROPOSED Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. REAR •RELEVATION BUILDING FASCIA 1. Repair & Seal Penetrations 2. Repair & Refurbish Damaged Corner of Canopy SQUARESIGNAGE • • EXISTING: 4.0 SQ FT PROPOSED: 2.99 SQ FT ALLOWED: 100.0 SQ FT Total For Building Service order to repair the edge of the drive thru canopy has been provided. WORK ORDER #2028741. i -----------I-----------, I � l - _------------ EXI----------'- I I l I I CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. DWg By: CIVIC This includes ro er roundin and bonding of the sign. Date: 1.24.19 P P I 9 9 9 9 Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 13 2'-11 3/4" 0 NON ILLUMINATED 12" FCO LETTERS 14 SCALE: 1-1/2" = 1' o" (1) REQ'D P1 © SECTION @ FCO LETTERS 14 SCALE:NTS Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. -----------I-----------t I � I I � I L ----------- ----------------------- CENTER SIGN IN AVAILABLE AREA All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. DWg By: CMC This includes ro er roundin and bonding of the sign. Date: 1.24.19 P P I 9 9 9 9 COLORS & FINISHES P1.E PAINT: Match (PMS 187C) SIGN CONSTRUCTION 1. COPY: 1/2" Routed Acrylic Painted Red INSTALLATION HARDWARE 2. HARDWARE: 1/4-20 X 2" Long Studs Threaded Into Backside. Min (3) Per Element. BUILDING & FASCIA CONDITIONS 3. WALL SURFACE: Varies Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 14 10'-8" r a- EXISTING PROPOSED - DAY TIME A Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 Your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is CIMIC) Chalfont, PA 18914 www.cimanetwork.com not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited inany fashion without the expressed constentofCimaNetwork, Inc. SIGNAGE SQUARE • • REFACING WITH IDENTICAL SIZED FACE. PROPOSED - NIGHT TIME All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meetthe requirements of Article 600 of the Dwg By: CMC National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding ofihesign. I Date: 1.24.19 I• Job#: 7405 Store#* 71626 Address: 314 Rolkin Rd. , Charlottesville, VA 22911 -0 3/8" Use Tracing For Fabrication 7'-6" 4'-7 5/16" O 0 ILLUMINATED MONUMENT REFACE 16 SCALE: 3/4" = 1' 0" (2) REQ'D P1 N oft RETAINER 16 SCALE: 3" = 1' 0" (4) 8' Straight Lengths (Cut In Field) (4) Routed & Fabricated Curved End Pieces Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CIVIC This includes ro er roundin and bonding of the sign. Date: 1.24.19 P P I 9 9 9 9 COLORS & FINISHES PF1.0 FACE: White (PMS Opaque White C) V1. 0 VINYL: 3M 3630-53 Cardinal Red (PMS 187C) V2. E VINYL: 3M Opaque 180C-77 Peacock Blue (PMS 542C) V3. ❑ VINYL: White Blockout P1. 0 RETAINER: SW 7048 Urbane Bronze (PMS 2335C) REFACE CONSTRUCTION 1. FACE:.177" Thk Polycarbonate Painted Opaque White. ONLY COPY TO ILLUMINATE. Blue Band to be 1 st Surface Vinyl Over White Blockout. Red Copy To Be 1 st Surface Trans Red Vinyl. Use Tracing To Cut Face. 2. RETAINER: 2" X 4" Angle Retainer w/ .063" x 1" x 1" Angle Inner Retainer. Cut To Size In Field ILLUMINATION 3. Existing White 84" Lamps (2) Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 16 CIMICI k T0 Leave As -is EXISTING Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. EXISTING All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. DWg By: CIVIC This includes ro er roundin and bonding of the sign. Date: 1.24.19 P P I 9 9 9 9 DIRECTIONALS 1. Remove Damaged Directional and Leave Other As -is Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 17 Project Name: Walgreens #17626 Date Requested: Street Address: 314 ROLKIN ROAD Date Completed: 1-8-19 City, ST Zip: Charlotteville, VA Contact for Zoning/Permitting: Bart Contact Phone Number: 434-296-5832 Address: Jurisdiction: City/Town: or, County of: Albermarle City, ST Zip: 1.Special codes, overlays, sign districts, PUD's, colors, historical or other restrictions regarding freestanding or building 2. Are there any approval boards? ❑ Yes ® No Planning Review? ❑ Yes ® No A. What documents are required and when? Architectural Board? ❑ Yes ® No Design Review? ❑ Yes ® No B. How often does the board meet? Other: C. When is the next available board meetine date? 3. Zoning C1 1 4. Permit Application Fee (if known) 5. Is ordinance available online? Please provide website and specify location of page that contains the ordinance: municode 6. Permit Timeframe (incl. expiration date): 10-20 days 7. Will code be changed in the near future? No 8. Permit Process as described in local code: In the C-1 and CO districts, 1.5 square feet per 1 linear foot 9. Formula for calculating wall sign square footage of establishment structure frontage, not to exceed 100 square (max sq footage - primary & secondary signs) feet; 10. Are Sign calculations boxed or other means of determining? box 11. Sq Ft allowance for elevations: Primary: (L) Side: (R) Side: Rear: 12. Are allowances transferable? Walls with fronts 13. Total # of Wall Signs allowed per elevation: above 14. Min/Max height from top of sign to grade: NA 15. Can sign exceed roofline? 16. Maximum Letter Height: 17. Maximum projection from building face: 18. Internal illumination allowed? ❑ Yes ® No NA above ® Yes ❑ No 1 per street frontage, or 2 per entrance, per lot with 100 or more feet of continuous street frontage plus 1 per lot if the lot is greater than 4 acres and has more than 1 approved entrance on its frontage. 32 square feet, plus bonus tenant panels; if more than 1 sign at an entrance, no single sign shall exceed 16 square feet In the C-1 and HC districts overall height, 12 feet; 16 feet in all other districts 21. Are permits required for face changes? yes 22. If existing F/S sign is legal, non conforming, are we grandfathered and able to keep same SF if replacing the cabinet an d/or providing face replacements? Face replacement only 23. Are there any issues with keeping existing F/S signs at existing height in this jurisdiction? NO you can replace face with permit. 24. Number of F/S Signs allowed: 1 25. Height Maximum: 8' 26. Clearance from grade to sign: NA 27. Internal illumination allowed? ® Yes ❑ No 28. Set -back of sign from right-of-way to property line: 5' from ROW 29. Is permit required? ® Yes ❑ 1 or more per establishment, as authorized by zoning administrator. 24 square feet. Must be 5' from ROW 30. Maximum Sq Footage: above 31. Maximum Height: 6` 32. Does sign(s) count toward square footage? Yes for that type sign. 33. Number of signs allowed: above 34. Internal illumination allowed? ® Yes ❑ No Sign Criteria is reported as presented to us as ofthe "Date Completed." Cima Network Inc. is not responsible for changes in local sign code after the completion date, nor for the review process, interpretations, calculations or fees oflocal authorities. Where required by local authority, it is understood ape rmit will be obtained prior to manufacture. Information provided herein may not be used or disclosed without written consent by Cima Network, Inc. Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. All Electric Signs to be manufactured to meet the requirements of Client: Walgreens UI 48 and installed to meet the requirements of Article 600 of the DW B : CIVIC Electrical Code and/or other applicable local codes. g Y This includes propergrounding and bonding ofthe sign. I Date: 1.24.19 Job#:7405 Store#:71626 Address: 314 Rolkin Rd. Charlottesville, VA 22911 REV 10.21.19 10 SHT of 19 18 35. Are temporary or "grand opening" banners ® Yes ❑ No allowed? 37. Are freestanding temporary signs allowed? 1 per street frontage per establishment. 32 SF. 12 feet, if freestanding sign; 20 feet, if residential wall sign; 30 feet if nonresidential ® Yes ❑No wall sign, but not to exceed the cornice line. 619 • : MA 1. Is there a variance appeals process? 3. Variance Meeting Date: MONTHLY 5. Time required to process: 90-120 DAYS Plot Plan Installation Drawings Graphic Drawing 7. Is current sign under a variance? ® Yes ❑ No only 36. Is permit required? ® Yes ❑ No 38. Is permit required? ® Yes ❑ No 2. Estimated Variance Application Fee? 1500.00 4. Application Deadline: TBD # of sets of prints: 3 ® Photo of Existing ® Legal Description ® Building Elevations ID Stress Analysis ❑ ® Selected Engineering Drawings ID Other: ❑ Yes ® No 1. Are signed/sealed engineering drawings required? ❑ Yes ® No 2. How many sets? 3. Calculations and drawings both required? ❑ Yes ® No 4. Building / Structural code required? ❑ Yes ® No 5.Buildine code vear: 1. Are signed/sealed engineering drawings required? 3. Calculations and drawings both required? 4. Electrical code year: 5. Check all necessary Items: ® Electrical hook-up included with sign permit ® List of UL numbers ® Yes ❑ No ® Yes ❑ No 2. How many sets? 3 ® Electrical permit required by licensed electrician ® UL Label visible after installation 1. Inspections required? 2. Third party inspections required? 3. Contact for inspection: 4. Advanced notice requirements: ® Yes ❑ No ❑ Yes ® No Formula for calculating wall sign square footage (max sq footage — primary & secondary signs) Sq Ft allowance for elevations: Primary: Formula for calculating F/S sign square footage (max sq footage — primary & secondary signs) Sign Criteria is reported as presented to us as of the 'Date Completed." Cima Network, Inc. is not responsible for changes in local sign code after the completion date, nor for the review process, interpretations, calculations or fees oflocal authorities. Where required by local authority, it is understood a permit will be obtained prior to manufacture. Information provided herein may not be used or disclosed without written consent by Cima Network, Inc. Cima Network Inc. office: 267.308.0575 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for 121 New Britain Blvd. fax: 267.308.0577 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied Chalfont, PA 18914 www.cimanetwork.com or exhibited in anyfashion withoutthe expressed constent of Cima Network, Inc. Contact Information: (L) Side: (R) Side: Rear: All Electric Signs to be manufactured to meet the requirements of Client: Walgreens Job#: 7405 Store#: 71626 UI 48 and installed to meet the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. Dwg By: CMC Address: 314 Rolkin Rd. This includes propergrounding and bonding ofthe sign. I Date: 1.24.19 Charlottesville, VA 22911 REV 10.21.19 10