Loading...
HomeMy WebLinkAboutARB201900072 Correspondence 2019-09-30 Gi GOODHOUSE DESIGN Goodhouse Design,LLC 2079 Hawkshill Ln. Charlottesville,VA 22911 Phone: 434.295.5959 September 30,2019 Margaret Maliszewski County of Albemarle Department of Community Development 401 McIntire Rd. Charlottesville,VA 22902 Re: ARB-2019-72: 1193 & 1205 Crozet Ave. Memorandum: detailing responses to ARB conditions for final site plan approval,dated 08.07.19 1. Two species of native flowering perennials have been added to the planter,and its planting layout has been revised. 2. The number of fixtures across the site have been reduced to the minimum required for safety and security: a. Fixture D(Path Lights): Along north edge of site,number of fixtures reduced from(5)to(3). At southwest corner of site,number of fixtures reduced from(2)to(1). b. Fixture F(Utility Bulkhead): In each enclosure,number of fixtures reduced from(2)to(1). c. Fixture G(Wall Washer): Along the rear facade of the building,number of fixtures reduced from (4)to(3). d. A note about the porch fixtures: Fixtures A(decorative pendant)and H(sconce)are wired on one circuit,and Fixtures B(recessed)are wired on a second circuit. Though the photometric plan shows both circuits turned on together(yielding less than 20 fc in all locations),we do not anticipate this being the case except very late at night,briefly,to accommodate cleaning tasks. Most of the time that lights are needed on the porch,we plan for the recessed lights to be off or dimmed very low. 3. The type and quantity of fixtures in this lighting plan have been adjusted to maintain footcandle values of 20 or less across the site. 4. The photometric plan has been recalculated with an LLF equal to 1.0. 5. The luminaire schedules have been rectified to provide the correct quantity of all light models shown on the lighting plan. 6. The photometric plan has been revised to provide fc values on the property lines,and we have ensured that there is no spillover..in excess of 0.5 fc onto any public right-of-way. 7. The luminaire schedule has been revised to provide the initial lumens for each fixture. 8. The manufacturer specifications in the attached lighting fixture cut sheets have been revised to provide the finish colors of light models'A and E 9. An alternate model for Fixture F is proposed which has a color temperature of 3000K. 10. The standard lighting note hias,been added to sheet E102. Written By Katherine Pabody,Goodhouse Design