Loading...
HomeMy WebLinkAboutSDP201900058 Action Letter Initial Site Plan 2019-10-29COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 October 29, 2019 Revised Final Version Scott Collins 200 Garrett Street, Suite K Charlottesville VA 22902 SDP201900058 2415 Ivy Road Commercial Redevelopment Plan - Initial Site Plan Dear Mr. Collins: Pursuant to Albemarle County Code §32.4.2.1(c) the above referenced initial site plan is deemed incomplete and shall not be accepted for official submittal by the agent. Below I offer the reasons for the disapproval. In order for the initial site plan to be accepted as officially submitted, please revise the plan to address the following within 15 days of this notice: [32.5.2(b), 32.5.2(s), 22.2.2(15)] Information regarding the proposed use. The warehouse use requires a Special Use Permit in the C-1 Zoning district. If the warehouse is not completely accessory to other uses onsite it will require a Special Use Permit. The level of a use deemed accessory will be subject to review and determination by the Zoning Administrator. If a Special Use Permit is required, prior to conditional approval of the initial site plan the Special Use Permit shall be approved by the Board of Supervisors. On the site plan clarify the proposed warehouse use; specifically, how much square footage of the warehouse use is used for each of the various proposed uses onsite, and clarify which uses? Based on conversations with the applicant there is no warehouse use proposed; rather, the proposed use is office. Update the site plan to reflect the correct uses. Also, provide the location of the office use within the building. 2. [32.5.2(b), 32.5.2(s), 22.2.1(18)] Information regarding the proposed use. Once the above warehouse use is clarified, will the Manufacturing/Processing/Assembly/Fabrication use remain below the 4,000 SF threshold, or will this use go over 4,000 SF thereby requiring a special exception? If a special exception is required please make the request and provide the appropriate justifications. Prior to conditional approval of the initial site plan the special exception shall be approved by the Board of Supervisors. 3. [32.5.2(1) Existing and proposed utilities. Depict the location of the existing gas line and gas easement. 4. [32.5.2(j)] Existing sewer and drainage facilities. Depict the location and size of the existing water and sewer facilities to the building. 5. [32.5.2(k)] Proposed sewer and drainage facilities. Depict the conceptual layout for the water and sewer facilities. 6. [32.5.2(k)] Proposed sewer and drainage facilities. Depict the direction of flow in all pipes and watercourses with arrows. 7. [32.5.2(q)] Traffic generation figures. Provide traffic generation figures for the site based on current Virginia Department of Transportation rates; indicate the estimated number of vehicles per day and the direction of travel for all connections from the site to a public street. 8. [32.5.2(m)] Ingress and egress. Show the distance to the centerline of the nearest street intersection from the proposed ingress and egress. 9. [32.5.2(a)] General information. Provide the present uses of abutting parcel. 10. [32.5.2(n)] Existing and proposed improvements. Depict and label the loading and service areas. While not a reason for this plan to be deemed incomplete, below I offer additional revisions that should take place otherwise they will be conditions of initial site plan approval. 1. [32.5.2(b), SP2004-21, 4.12] Information regarding the proposed use. The Zoning Administrator previously determined through a parking determination that 8 parking spaces are required for the Ballet School. Revise the parking analysis on sheet 3 to utilize the above parking calculation for the Ballet School. 2. [32.5.2(b), 32.5.2(s), 22.2.2(15)] The parking analysis on sheet 3 lists "Warehouse: 4,000 SF (part of the Office Building)" on TMP 60-2513; however, there is not an approved warehouse use on that property. Per conversation with the applicant this use is truly office. Revise the parking analysis. 3. [32.5.2(b), 32.5.2(s), 22.2.1(18)] Information regarding the proposed use. Throughout the plan ensure the square footages of all proposed uses are consistent. 4. [32.5.2(n)] Existing and Proposed Improvements. Depict and label the proposed paving materials for all walkways, parking lots, and dumpster pads. 5. [32.5.2(n)] Existing and Proposed Improvements. Dimension all parking spaces onsite. Within fifteen (15) days after the date this notice of disapproval is provided to the applicant, the developer may resubmit the initial site plan, as provided by Albemarle County Code §32.4.2.l(d). If a revised plan is not received within 15 days, the plan shall be deemed to be disapproved and a new application and fee shall be required for submittal of the plan. Sincerely, Christopher Perez, Senior Planner Planning Services File: SDP201900058