Loading...
HomeMy WebLinkAboutSDP201900048 Application 2019-08-06 • l.�+5,-",k,; Albemarle Coiii'L GoniniunityDevelopmentDe,�art `. ! ` +�.,A bemarla C tiro Community niaratattesvi38e,4!�229D2 969t .,0 :::;' e:(434)2905832 Fax:(434)972-4128 ,., t.,• ,�*. ,, :Planning Application PARCEL/ OWNER INFORMATION TMP .:.07$00-00=00=06400 Owner(s): KIMCO,'t.C Application# 50P20190004 " , PROPERTY INFORMATION Legal Description ,PAI4TOR54' w Magisterial Dist.IRivanna . `✓ Land Use Primary'Open CurrentAFD Not;in.A/F District IT Current Zoning Primary Planned Development Mixed Commercial ' APPLICATION INFORMATION Street Address Entered By i Jennifer Pritcl- v Application Type [Site Development Plans . - i'.. 1/772 Project Hampton Inn:- Initial - ' Received Date 0B/06/19 Received Date Final _ ' Submittal Date 08/26/19 Total Fees Closing File Date Submittal Date Final • Total Paid Revision Number Comments Legal Ad ; • A; SUB APPLICATION(s) ' • Tape Sub Applicatio " - Comment , . Initial'Site''Plan; , - . Oil 06j19,. „. , .,' ;; , APPLICANT/CONTACT INFORMATION GontactType Name Address. CityState •� , Zip .Phone - PhoneCell yOwreriAp^,ii,_=rt '.: "♦•:Ih1CO3.L C ,.'_i'.:;;-.:'.. : , 1510.E HIGH STREET':::.-''.;�: CHARLOTTES<QLL 22901' :43477790QQ - ':'": Primary Ccrt-ct JOHN C'WRIGHT,PE 28 BLaCf:4VELL PARK LANE a WARRENTON,'VA 20186 5403494500 • it Signature of Contractor or Authorized Agent Date a i - Application for Initial Site Plan or Final Site Plan or Site Plan Exception Project Name: Hampton Inn Tax map and parcel(s): 07800-00-00-06400&07800-00-00-06500 Zoning: PDMC Contact (who should we contact about this project)Bohler Engineering VA,LLC-John C.Wright,P.E. Street Address 28 Blackwell Park Lane,Suite 201 City Warrenton State VA Zip Code 20186 Phone Number (540)349-4500 Email jwright@bohlereng.com Owner of Record PT Hotel,LLC Street Address 2000 Ware Bottom Spring Road City Chester State VA Zip Code 23836 Phone Number (434)777-9000 Email Neil@Shaminhotels.com Applicant PT Hotel,LLC-Mike Sweeney Street Address 2000 Ware Bottom Spring Road City Chester State VA Zip Code 23836 Phone Number (804)777-9000 Email Michael@Shaminhotels.com Type of Development U Residential ® Non-residential Type of unit(s): ® Commercial ❑ Industrial #of building(s): ❑ Quasi-Public Sq.ft.of building(s): Sq.ft.of building(s): 60,471± #of units per building: Acreage of site: 4.42 Total#of units: Acreage in open space: 2.00(For future dedication to county) Resulting density: Acreage in roads: N/A Acreage of site: Average gallons of water used per day: 22,000 Acreage in open space: Acreage in roads: Average gallons of water used per day: FOR OFFICE USE Oly SDP# �yJ Fee Amount$2192.� ate Paid IQpBy who? ceipt#I (��Z�i Ck# /O (Q/By: County of Albemarle Department of.Community Development 401 McIntire Road Charlottesville,TVA 22902 Voice: (434)296-5832 Fax: (434)972-4126 REVISED 4/05/2019 Page 1 of 2 e - - Ink-tided use or justification for rer_ Proposed 6 story hotel with parking an sociated site improvements. Comments/Attachments: FEES SITE DEVELOPMENT PLAN SITE PLAN EXCEPTION Initial Site Plan Final Site Plan Exception to drawing of site plan under section 32.3.5(a) Approved No Preapplication plan Preapplication plan U $752 plus$16/dwelling ® $1,290 plus$16/dwelling U $1,613 ❑ $1,613 unit and/or$0.016 per unit and/or$0.016 per +Fire Rescue Fee of$100 +Fire Rescue Fee of square foot of square foot of $100 nonresidential structure nonresidential structure $J 1+Fire $J 2.257.54 t+Fire Rescue Fee of$100 Rescue Fee of$100 16 folded copies of the plan #of copies required for submittal will be noted with 8 folded copies of the plan plus an additional 6 copies if within an Entrance Corridor your initial approval letter. Copies of the plan should be folded and in blue or black ink.Also provide 1 reduced copy of the plan no larger than 11 by 17 in. U The initial site plan has a parking structure. ❑ The final site plan has a parking ❑ Included are architectural elevations,drawings, structure. photographs or other visual materials showing any ❑ Included are revised architectural elevations, parking structure proposed on the site and surrounding drawings,photographs or other visual structures and land uses. materials submitted with the initial site plan. The elevations shall be part of the approved fmal site plan. GROUNDWATER ASSESSMENT (Required for all non-residential site plans not serviced by public water) ❑ If the plans show a use using less than 2,000 gallons/day(average) Tier 3 Groundwater Review=$548 ❑ If the plans show a use using greater than 2,000 gallons/day(average) Tier 4 Groundwater Review=$1,183 U Special Exception=$457 This application may require additional review by the Fire Marshal. Fees in addition to those shown on this application may be required by the Fire Prevention Code Fee Schedule. A copy of the schedule is available from the Fire Marshal. Notices required by Section 32.4.2.1(f) Initial notice fee to be provided in conjunction with an application,for preparing and mailing notices and published notice=$435.00 Owner/Applicant Must Read and Sign This site plan as submitted contains all of the information required by Section 32.5(Initial Site Plan)or Section 32.6(Final Site Plan)of Chapter 18 of the Code of the County of Albemarle. I understand that plans which lack information required by said sections shall be deemed incomplete and shall be denied by the agent within ten(10)days of submittal as provided in Section 32.4.2.1 or Section 32.4.3.1 of Chapter 18 of the Code as the case may be.By signing this application I am consenting to written comments,letters and or notifications regarding this application being provided to me or my designated contact via fax and or email. This consent does not preclude such written co unication from also being sent via first class mail. For Fjl}a Tans Only:To the best of my knowledge,I have complied with Section 32.4.3.1(a)of Chapter 18 of the Code. / / 0lff11 Signs a of Owner,Contract Purchaser,Agent Date Al 1 /4w.,,, ever-3pl --ei 05 Print Name Daytime phone number of Signatory Site Plan Application REVISED 4/05/2019 Page 2 of 2 • itial Site Plan11110 � " ��s Checklistsillo , Project Name: Hampton Inn Firm: Bohler Engineering VA,LLC This checklist must be completed, signed and submitted with the application. The information contained in this checklist reflects the contents of the Section 32 of Chapter 18 of the Code of the County of Albemarle also known as the Site Plan Ordinance as of January 1,2013. The applicant is responsible for insuring that no revisions to the Ordinance have occurred since preparation of this document. Plans which lack the information required by this checklist shall be deemed to be incomplete and shall be denied by the agent with ten (10) calendar days after the applicable submittal deadline[Section 32.4.21. An Initial Site Plan shall contain the following: Cl [32.5.1 a]Number of copies. ❑ Sixteen (16) clearly legible copies in blue or black ink of the plan shall be submitted. li [3 .5.2 lb] Scale and size. tki The plan shall be prepared to the scale of one(1) inch equals twenty(20)feet or to another scale approved by the / agent in a particular case. No sheet shall exceed forty-two (42) inches by thirty-six (36) inches in size. ® The plan may be prepared on one(1) or more sheets. If prepared on more than one (1) sheet, match lines shall clearly indicate where the several sheets join. The top of the sheet shall be approximately either north or east. ❑ [32.5.1 c] Dimensions. ❑ Tile plan shall be dimensioned to at least the following standards for accuracy: 011 Boundary, setback and zoning lines: One foot in one thousand(1:1,000) feet. ❑ Existing contours: One-half(1/2) of the contour interval required in.section 32.5.2(d). d Proposed contours: Within five(5) feet horizontally and vertically. ❑ Existing structures,utilities and other topographic features: Within five(5)feet. ❑ Proposed structures, roads,parking lots and other improvements: Within five (5) feet. ❑ [32.5,2 a]General information. Igil The name of the development; names of the owner, developer and individual who prepared the plan; tax map and parcel number; boundary dimensions; zoning district; descriptions of all proffers, special use permits and conditions thereof, special exceptions and conditions thereof,variances and conditions thereof, application plans, codes of development and bonus factors applicable to the site; magisterial district; county and state; north point; scale; one datum reference for elevation (where section 30.3, flood hazard overlay district, is involved, United States Geological Survey vertical datum shall be shown and/or correlated to plan topography); 1C the source of the topography; l departing lot lines; d minimum setback lines, yard and building separation requirements; a the source of the survey; G, sheet number and total number of sheets; and Ethe names of the owners, zoning district,tax map and parcel numbers and present uses of abutting parcels. County of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434)972-4126 REVISED 06/10/2015 Page 1 of 4 4 my of Albemarle- Initial Site Plan Checklist 4141, , (32.5. b] Information regarding the proposed use. Oil Written schedules or data as necessary to demonstrate that the site can accommodate the proposed uses, including proposed uses and maximum acreage occupied by each use; maximum number of dwelling units by type including the number of bedrooms for multifamily dwellings; gross residential density; square footage of recreational areas; the percentage and acreage of open space; maximum square footage for commercial and industrial uses; maximum floor area ratio and lot coverage for industrial use; maximum height of all structures; schedule of parking including the maximum amount required and the amount provided; the maximum amount of impervious cover on the site; and if a landscape plan is required, the maximum amount of paved parking and other vehicular circulation areas. i. [42.5.2 cJ Phase lines. ® If phasing is planned, phase lines and the proposed timing of development. 6Z( `i2.5.2 dJ Topography and proposed grading. Existing topography(up to twenty [20] percent slope,maximum five [5]foot contours, over twenty[20] percent slope,maximum ten [10] foot contours) for the entire site with sufficient offsite topography to describe prominent and pertinent offsite features and physical characteristics,but in no case less than fifty(50) feet outside of the site unless otherwise approved by the agent; proposed grading(maximum five [5] foot contours) supplemented where necessary by spot elevations; areas of the site where existing slopes are critical slopes. ❑ [32.5.2 e] Landscape features. --- ❑ The existing landscape features as described in section 32.7.9.4(c). 0 [32.5.2 fJ Watercourses and other bodies of water. The name and location of all watercourses and other bodies of water adjacent to or on the site; indicate whether the site is located within the watershed of a public water supply reservoir. 6 [ 2.5.2 gJ Onsite sewage system setback lines. 01 The location of onsite sewage system setback lines from watercourses including intermittent streams and other bodies of water. 1 [32.5.2 hi Floodplain and related information. ® The boundaries of the flood hazard overlay district, the base flood elevation on the site,the elevation of the lowest floor, including any basement, and for any structures to be flood-proofed as required by section 30.3,the elevation to which the structures will be flood-proofed. [ 2.5.2 iJ Streets, easements and travelways. The existing and proposed streets, including proposed bike lanes, access easements, alley easements and rights-of-way, and travelways, together with street names, state route numbers, right-of-way lines and widths, centerline radii and pavement widths. REVISED 06/10/2015 Page 2 of 4 ell unty of Albemarle-Initial Site Plan Checklist a [32.5.2 jJ Existing sewer and drainage facilities. 0 The location and size of 9/ existing water and sewer facilities and easements, the storm drainage system, drainage channels, and —/ drainage easements. Isd [32.5.2 kJ Proposed sewer and drainage facilities. In The proposed conceptual layout for el water and sewer facilities and 42.5.2 d] the storm drainage system, indicating the direction of flow in all pipes and watercourses with arrows. lJ Existing and proposed utilities. 70. T e location of other existing and proposed utilities and utility easements, Dill including existing telephone, 0 cable, [ electric and / ji gas easements. ® [31.5.2 m] Ingress and egress. lell The location of existing and proposed ingress to and egress from the property, i Show the distance to the centerline of the nearest existing street intersection from the proposed ingress and egress. U [ 2.5.2 n]Existing and proposed improvements. The location and dimensions of all existing and proposed improvements including buildings(maximum footprint and height)and other structures; walkways; fences; walls; Ill trash containers; .—), U outdoor lighting; Cl landscaped areas and open space; ,� q recreational areas and facilities; gj parking lots and other paved areas; loading and service areas; signs; and ❑ the proposed paving material types for all walks,parking lots and driveways. d [32.5.2 of Areas to be dedicated or reserved. UAll areas intended to be dedicated or reserved for public use under sections 32.7.1.1, 32.7.1.2 and 32.7.1.3, and shall include a note on the plan stating that the land is to be dedicated or reserved for public use. ❑ [32.5.2 pi Landscape plan. --i ❑ A landscape plan that complies with section 32.7.9,if it is required to be submitted with the initial site plan. 12i [3 .5.2 qJ Traffic generation figures. ila If deemed appropriate by the agent due to the intensity of the development, estimated traffic generation figures for / the site based on current Virginia Department of Transportation rates; ® indicate the estimated number of vehicles per day and the direction of travel for all connections from the site to a public street. li [ 2.5.2 dSymbols and abbreviations. ll A legend showing all symbols and abbreviations used on the plan. i REVISED 06/10/2015 Page 3 of 4 • ) } my of Albemarle-Initial Site Plan Checklist ., Cal [32.5.2 sJ Additional inform dJ The agent may require additi 1 information to be shown on the initial si Ian as deemed necessary to provide sufficient information for the agent and the site review committee to adequately review the plan. Grading Permit Requirements—if you will be looking to obtain a grading permit and the initial plan is approved and you have satisfied the conditions of approval identified by the agent in the letter required by section 32.4.2.5(c) then a separate Water Protection Ordinance Application for an Erosion and Sediment Control Plan must be submitted for review and approval . In addition to the items required by the ordinance,Albemarle County Engineer,Groundwater Program Authority, the Virginia Department of Transportation,the Albemarle County Service Authority, and the Thomas Jefferson Health District require these items on plans submitted for initial approval. Plans will not be rejected if these items are not present, but they are required for approval. These items are provided in an effort to communicate all initial comments. t✓J 1. Reference the benchmarks used for surveys. (Albemarle County Engineering Policy) l 2. Indicate the available sight distance for entrances and left turn lanes. (Albemarle County Engineering Policy) 121 3. Label the maximum height of all retaining walls. (Albemarle County Engineering Policy) d 4. Provide copies of off-site easements, or letters of intent to grant them from off-site property owners. (Albemarle County Engineering Policy) 1 5. Show and label stream buffer limits. (WRPA Ordinance) /6. Indicate the deed book and page reference for all existing utility easements located on the property. (Albemarle County Service Authority) -$7 ❑ 7. Tier 3 -Draft Groundwater Management Plan (17-403) lv _.,, ❑ 8. Tier 4—Aquifer testing work plan (17-403) Read and Sign I. presen ing the above referenced firm submitting this plan for initial approval, I hereby sate that,to the best of my knowledge,the 4161,d ft conta' all in rmatio eq red by this checklist. ./.00' - le'/5 il 1 Signature of Owner,Contract P rc s ,Agent Date Print Name Daytime phone number of Signatory REVISED 06/10/2015 Page 4 of 4