Loading...
HomeMy WebLinkAboutSDP201900059 Review Comments Initial Site Plan 2019-12-03COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 December 3, 2019 Mr. Craig Kotarski, P.E. — Timmons Group 608 Preston Avenue, Suite 200, Charlottesville VA 22903 (434)-327-1688 / craig.kotarskiAtimmons.com Mr. Chris Schooley — UVA Foundation P.O. Box 400218, Charlottesville, VA 22904 (434)-982-3777 / cschooleykuvafoundation.com RE: SRC Comment Letter for SDP-2019-00059 (UVAF Discovery Drive — Initial Site Plan—10/21/2019) Mr. Kotarski and Mr. Schooley: The Planner for the Planning Division of the Albemarle County Community Development Department (CDD) and other members of the Site Review Committee (SRC) have reviewed the development proposal referenced above. Initial review comments from the following SRC members are included in this comment letter: Albemarle County Engineering Services (CDD-Engineering) — PENDING Albemarle County Planning Services (CDD-Planning) Albemarle County Planning Services (CDD-ARB) Albemarle County Building Inspections (CDD-Inspections) Albemarle County Information Services (CDD-E911) Albemarle County Department of Fire Rescue (ACFR) Albemarle County Service Authority (ACSA) — PENDING Virginia Department of Transportation (VDOT) Each comment is preceded by the applicable reference to Chapter 18 of the Albemarle County Code (Zoning Ordinance) unless otherwise specified. (The following comments are those that have been identified at this time; additional comments may be added or eliminated based on further review.) The Planner will either approve with conditions or deny the Initial Site Plan within 15 days of the Site Review Committee Meeting. Please contact me at your earliest convenience if you have questions about this comment letter, the applicable regulations, or any other issue involving your application, or if you otherwise require additional information or assistance prior to the SRC Meeting on Thursday, December 5. Sincerely, rVlr /�� f, P—Let['i�v Tim Pad 1 o, AICP Senior Planner / Community Development Department — Planning Division (434)-296-5832 x 3088 / tpadalinogalbemarle.org Page 1 of 4 Albemarle County Planning Services (CDD-Planning): Contact: Tim Padalino / ttpadalinokalbemarle.org Review Status: Requested Changes (12/3/19) 1. [ZMA200500003; Z.O.32.5.2.(a)]: The proposed development shown on the initial site plan appears to be in general accord with the Application Plan and consistent with the Proffer Statement for approved ZMA200500003. 2. [ZMA200500003; Z.O.32.5.2(a)]: Please revise the "Notes" on the Cover Sheet (Sheet C0.0) as follows: A. In the "Zoning" information, include reference to ZMA200500003 (approved by the BOS on 3/10/2010). B. In the "Setbacks" information, include reference to the "Buffer Area" requirements established by ZMA200500003 Proffer 7.2 (`Buffer Areas"). Please note that Exhibit K of the ZMA200500003 Application Plan shows a 50' Buffer Area along the side boundaries of TMP #32-19E ("Tract F-lA") and a 150' Buffer Area along the rear boundary of TMP #32-19E ("Tract F-lA"). Staff acknowledges that these Buffer Areas are correctly depicted on the sheets in this site plan; however, this information needs to also be noted on Sheet C0.0. For reference, an excerpt of Proffer 7.2 is provided below: 7.2 Buffer Areas. Except as expressly provided herein in Sections 7.2 (A) and 7.2 (B), the Owner shall not disturb the Buffer Areas (the "Buffer Areas") as depicted on the Application Plan, other than to: i) establish and maintain signage, fences or walls, ii) remove underbrush, iii) plant landscaping trees for screening or (iv) construct an interconnection along the eastern boundary between development parcels B 10 and B I 1 as shown on Exhibit K. The Owner shall plant additional landscaping in Buffer Areas as reasonably required for screening. 3. [ZMA200500003; Z.O.32.5.2.(b), 32.5.2.(d), 32.5.2.(n)]: Per CDD-Planning review of Sheet C2.0 ("Existing Conditions," showing the location of the Managed Steep Slopes overlay district and the location of the 150' rear Buffer Area) and Sheet C4.1 ("Layout and Utilities — Phase 2," showing a proposed retaining wall with a maximum height of 14'), it appears that the proposed improvements comply with applicable Zoning Ordinance regulations and requirements of ZMA20050003, as shown in this annotated excerpt: RETAINING WALL WITH HANDRAIL (BLACK POWDER COAT FINISH) ;CAT FINISH) a4 I..,....}...;..,..,,�........... ISO' Buffer .............. Area --- .I...J...[° ...I...I...�...a... S CONCRETE SIDEWALK ....p.]...111 L.. Managed Steep Slopes Overlay District •- R5 �. RI O' •� CG-6 ■ III ��.... ... 24' • ; However, please be advised of the following details and considerations for the Final Site Plan: A. The proposed retaining wall appears to be located outside of the Managed Steep Slopes overlay district; however, if the proposed retaining wall were to be located within that overlay district, then the proposed structure (or the portions of the proposed structure within that overlay district) would Page 2 of 4 need to comply with all applicable design standards in Z.O. Section 30.7.5, which include a maximum wall height of six (6) feet (per Z.O. Section 30.7.5.a). It appears that portions of the proposed retaining wall would be located within the Managed Steep Slopes overlay district; as noted above, those portions would need to comply with all applicable design standards in Z.O. Section 30.7.5. Therefore, it appears that revisions to portions of the proposed retaining wall are necessary in order to comply with the design standards specified in Z.O. Sections 30.7.5.a.1 ("Wall height") and 30.7.5.a.2 ("Multiple stepped walls; separation"). B. The proposed retaining wall appears to be located outside of the 150' Buffer Area; however, please note that the northern end of the retaining wall as proposed would be very close to the 150' Buffer Area boundary. Per ZMA20050003 Proffer 7.2, land disturbance to establish walls is permissible within the Buffer Area (7.2.i), but the retaining wall must be located outside of the Buffer Area. As noted above, staff acknowledges that Sheet C4.1 ("Layout and Utilities — Phase 2") appears to show the proposed retaining wall being located outside of the 150' Buffer Area; and staff further acknowledges that Sheet C5.1 ("Grading and Drainage — Phase 2") does not show any proposed grading within the 150' Buffer Area in conjunction with the proposed retaining wall. ■ (Advisory / For Future Reference): A Landscape Plan is required with the Final Site Plan, per County Code §§ 18-32.6.20) and 18-32.7.9.2(a). Please note that the eventual review of the Landscape Plan during the Final Site Plan review process might potentially include a requirement to establish additional landscaping in one or more locations within the Buffer Area, as may reasonably be required for screening the proposed improvements from the adjoining Rural Areas zoning district, in accordance with ZMA200500003 Proffer 7.2 and if determined by the Agent to be reasonably required based on site visit(s) and/or additional site analysis. ■ (Advisory / For Future Reference): Please note that the Final Site Plan cannot be approved unless and until all the outdoor lighting information required by Z.O. 32.6.2(k) is provided to demonstrate compliance with all applicable outdoor lighting requirements as specified in Z.O. 4.17, per Z.O. 32.7.8.b. However, this information is not required prior to County approval of this Initial Site Plan (as may be applicable). ■ (Advisory / For Future Reference): Please note that the Final Site Plan cannot be approved unless and until a complete application for a Water Protection Ordinance Plan / VSMP Plan is submitted, reviewed, and approved by the Engineering Services Division of the Community Development Department as required per Z.O. 32.7.4.1 and County Code Chapter 17. It is anticipated that CDD-Engineering review comments will identify this requirement, as well as any other requirements relating to stormwater management and drainage control, including the dedication of easements for facilities for stormwater management required per Z.O. 32.7.4.2(a). Staff acknowledges the submission of VSMP application WPO201900060, which is currently under review. ■ (Advisory / For Future Reference): Please note that the Final Site Plan cannot be approved unless and until the owner/developer dedicates to the Albemarle County Service Authority for public use all water and sewer facilities required by this chapter that are designed, constructed and approved to be dedicated as public water supply and public sewage systems, and to establish an easement on the land appurtenant thereto and extending to any abutting property identified by the agent easements, as required per Z.O. 32.7.5.3. ■ (Advisory / For Future Reference): Per Z.O. Sections 32.6.2(a), 32.5.2(1), and 32.5.2(o), it will be necessary prior to final site plan approval to obtain County approval of a plat showing all proposed easements as well as all areas intended for reservation or dedication to the County for public use (as may be applicable). The platting of proposed easements and lands to be reserved for dedication to the County for public use (as may be applicable) can all be processed together in one plat application, or separately, however the applicant prefers. ■ (Advisory / For Future Reference): Per Z.O. Sections 32.4.3.6.a and 32.4.3.6.c, please note that the Final Site Plan cannot be approved unless and until all other applicable SRC members review the Final Site Plan and indicate their tentative approvals prior to final approval (as may be applicable) by the agent in CDD-Planning. Page 3 of 4 Albemarle County Engineering Services (CDD-Engineering): Contact: David James / djameskalbemarle.org Review Status: Pending (as of 12/3/19) — CDD-Engineering review comments will be forwarded upon receipt Albemarle County Planning Services (CDD-ARB): Contact: Margaret Maliszewski / mmaliszewskigalbemarle.org Review Status: No Objection (1l/15/19) • (see attached CDD-ARB review comments) Albemarle County Building Inspections (CDD-Inspections): Contact: Michael Dellinger / mdellingergalbemarle.org Review Status: Requested Changes (11/21/19) • (see attached CDD-Inspections review comments) Albemarle County Information Services (E911): Contact: Andy Slack / aslack(&albemarle.org Review Status: No Objection (9/25/19) e (see attached CDD-E911 review comments) Albemarle County Department of Fire & Rescue (ACFR): Contact: Shawn Maddox / smaddox(a)albemarle.org Review Status: Pending (as of 12/3/19) — CDD-Engineering review comments will be forwarded upon receipt Albemarle County Service Authority (ACSA): Contact: Richard Nelson / rnelsonObserviceauthority.org Review Status: Requested Changes (11/21/19) e (see attached ACSA review comments) Virginia Department of Transportation (VDOT): Contact: Adam Moore / Adam.Moore(a)vdot.vir ig nia.gov Review Status: No Objections (11/21/19) (see attached VDOT review comments) Page 4 of 4 Review Comments for SDP201900059 11nitial Site Plan Project Name: UVAF DISCOVERY DRIVE - INITIAL - DIGITAL Date Completed: Fnday, November 15, 201 DepartmentlaivisionlAgency: Review Status: Reviewer: Margaret M al i szews ki �3 CBBARB I No Objection Nd The building proposed in this application is not expected to be visible from the Entrance Corridor_ Consequently, ARB review..'approval is not required_ Page: County of Albemarle Printed On: 12)02)2 119 Review Comments for SDP201900059 11nitial Site Plan Project Name: U AF DISCOVERY DRIVE - INITIAL - DIGITAL Date Completed: Thursday, November 21, 201 DepartmentlaivisionlAgency: Review sus: Reviewer: Michael Dellinger 7-1 CDD Inspecti I Requested Changes Nd Add the following note to the general notes page: Accessible parking spaces and access isles shall not have a surface slope greater than 1:48_ Access isles shall be at the same level as the parking space they serve_ Accessible parking spaces shall be located on the shortest accessible route of travel from adjacent parking to an accessible building entrance. In parking facilities that do not serve a particular building, accessible parking spaces shall be located on the shortest route to an accessible pedestrian entrance to the parking facility_ Where buildings have multiple accessible entrances with adjacent parking, accessible parking spaces shall be dispersed and located near the accessible entrances_ Add the following to the general notes page: All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks_ Page: County of Albemarle Printed On: 1210212 119 Review Comments for SDP201900059 11nitial Site Plan Project Name: UVAF DISCOVERY DRIVE - INITIAL - DIGITAL Date Completed: Tuesday, November 05, 2019 DepartmentlaivisionlAgency: Review Status: Reviewer: Andrew S.1ack CDD E911 No Objection No objection_ Page: County of Albemarle Printed On: 12)02)2 119 Review Comments for SDP201900059 11nitial Site Plan Project Name: U AF DISCOVERY DRIVE - INITIAL - DIGITAL Date Completed: Thursday, November 21, 201 DepartmentlaivisionlAgency: Review Status: Reviewer: Richard Nelson =El AOSA El Requested Changes Nd Provide information on proposed addition use_ A Provide fixture counts_ Fire hydrant spacing from buildings are 40 feet_ The existing fire hydrant may need to be relocated_ Show valves for fire line and water service_ Show easement around meter vault_ Page: County of Albemarle Printed On: 12)02)2 119 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper, Virginia 22701 Charles A. Kilpatrick, P.E. Commissioner November 20, 2019 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Tim Padalino Re: UVA Foundation Discovery Drive - Initial Site Plan SDf-2019-00059 Re iew #1 Dear Mr. Padalino: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Timmons Group, dated October 10, 2019, and find it to be generally acceptable. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the VDOT Charlottesville Residency Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, a/[I� Adam J. "Moore, P.E.P Area Land Use Engineer Culpeper District VirginiaDOT.org WE KEEP VIRGINIA MOVING