HomeMy WebLinkAboutSDP201900057 Review Comments Initial Site Plan 2019-12-04 (5)1. kAl
kr .�
�'IRGiI31P
County of Albemarle
Department of Community Development
Memorandum
To: Herb White, WW Associates
From: Tori Kanellopoulos - Planner
Division: Planning Services
Date: December 4, 2019
Subject: SDP201900057- Stonefield Block D-1 - Initial Site Plan
The Planner for the Planning Services Division of the Albemarle County Department
Community Development will recommend approve the plan referred to above when the
following items have been satisfactorily addressed. (The following comments are those
that have been identified at this time. Additional comments or conditions may be added
or eliminated based on further review.) [Each comment is preceded by the applicable
reference to the Albemarle County Code.]
Initial Site Plan Comments:
Required Prior to Initial Site Plan Approval:
1. The Special Exception for the additional stories for this development must be
approved by the Board of Supervisors prior to conditional approval of the initial
site plan.
Required Prior to Final Site Plan Approval:
Planning (Tori Kanellopoulos)
2. 18-4.7/18-4.16/Stonefield Code of Development Green/civic%pen space:
a. The required open space for Stonefield is referred to `Green and civic
space' in Stonefield's Code of Development, which replaces the 18-4.7
open space and 18-4.16 recreation requirements. Refer to the Green/civic
space plan dated 03/21 /2011 and uploaded to ZMA2013-9 and ZMA2001-
7 as `Code of Development'. The 2011 plan shows where the required
green/civic space is located.
b. Show how this requirement is being met. This may be done with a table
(e.g. X square foot courtyard, Z square feet of green space with trees).
The green/civic space should also be labeled on the plan on at least one
sheet.
c. Location of green/civic space may vary from the 2011 plan, however the
amount must remain the same.
d. The final green/civic space for this application must match the Special
Exception request, if the request is approved.
3. 18-4.7/18-4.16/Stonefield Code of Development Green/civic%pen space: The
special exception request for this development appears to show a courtyard
within this development, which could contribute to green/civic space. Please
clarify if there is a courtyard and show it on the plan.
4. 18-4.12.8 Parking alternatives and 18-4.12.10 Shared parking:
a. Include the most up to date parking reduction request letter with this
application. Staff's most recent request is dated 08/16/2019, and a request
was not included with the submittal of this initial site plan.
b. The 08/16/2019 does not clearly explain how parking requirements are
being met and where required parking spaces are located. Additionally:
i. The letter requests 351 parking spaces for the apartment in Block
D-1 (labeled incorrectly in letter as D-2), while the site plan shows a
parking garage with 447 spaces. Are these additional spaces for
another use?
ii. Note that the maximum reduction for all uses participating in the
reduction request is 35 percent.
c. If any shared and/or off -site parking is requested, an instrument to assure
off -site parking per 18-4.12.8(e) will be required. This would be required if
the Block D-1 proposal was subdivided as its own parcel off of TMP 61W-
3-19A but continued to share parking with other parcels in Stonefield (as
SUB2019-150 seems to indicate).
5. 18-4.12.9 Street parking: It appears there may be street parking included with
this development, along Inglewood adjacent to the proposed building. Clarify if
there is street parking and include the spaces in the parking calculations. Ensure
they meet design standards (e.g. 9'X20'). If spaces are being removed, indicate
that on the demolition sheet.
6. 18-4.13 Loading spaces: This site plan references a loading space. Note that a
loading space per the County's Zoning Ordinance is not required for this
development and is optional.
7. 18-4.12.16 Parking space minimum design standards:
a. All parking spaces for this development must be shown on the site plan,
including those within the parking garage. Staff must be able to review and
scale all parking spaces and travelways to ensure they meet the minimum
design standards per 18-4.12.16.
b. Ensure that there are sufficient ADA-accessible spaces that meet design
standards requirements. The requirement is 7 ADA spaces (at least 2
being van -accessible spaces) for 201-300 dwelling units. ADA spaces
must be labeled on the site plan.
8. 18-4.12.19 Dumpster pad standards: Show the design of the dumpster/dumpster
pad area, so that staff can determine if 18-4.12.19 standards are being met.
9. 18-4.17 Lighting: Submit a lighting plan with the final site plan that meets the
requirements of 18-4.17 and ARB requirements. Indicate if there are any new
lights added. Cutsheets for new lights are required.
10.18-32.5.2 Contents of an initial site plan and 18-32.6.2 Contents of a final site
plan:
a. Note that the ownership information, boundary lines, DB/PG, and Tax Map
Parcel may need to be updated, based on the status of SUB201900150
and if this parcel is subdivided.
b. Include a note with the approximate number of each type of unit (e.g. X 1-
bedrooms, Y 2-bedrooms, and Z 3-bedrooms).
c. All new improvements must be shown on the `Site Layout Plan'. This
includes new landscaping and adjusted/new easements (not shown).
d. Include all required contents of a final site plan with the final site plan
submittal, including a grading plan.
e. Include estimates trip counts on the first sheet (trips per day).
11.18-32.7.4.2/18-32.7.5.3 Easements:
a. All new and revised easements must be shown on an easement plat,
which must be approved prior to final site plan approval. Updated
covenants/maintenance documentation must also be provided.
b. The Existing Conditions and Demolition Plan sheets should show existing
easements/utilities/structures, while the Site Layout Plan should show
new/revised easements/utilities/structures only.
i. For example, the Site Layout Plan should only show the relocated
filterra, not the existing filterra.
ii. If the ingress/egress easements are adjusted (as Sheet 1 indicates)
then the Site Layout Plan should show `revised ingress/egress
easement' and not the existing easement.
c. Clarify how the sidewalks will be maintained, as some will be onsite and
some will be offsite (that is, not located on the Block D-1 parcel being
subdivided through SUB2019-150). If the sidewalk maintenance easement
is being adjusted (as Sheet 1 indicates), revised maintenance easement
documentation and a revised Deed Book/Page Number must be provided.
d. Include reference to DB 4467 PG 302 for the Hydraulic ROW, as this
appears to be the most recent VDOT ROW dedication.
e. An easement for the Stonefield marquis sign should be provided, if the
parcel per SUB2019-150 for Block D-1 is ultimately subdivided, as the
sign would then be off -site.
12.18-32.5.5/18-32.6.3/18-32.7.3 Parking structures:
a. Include the following required information: The application for an initial
site plan shall include architectural elevations, drawings, photographs or
other visual materials showing any parking structure proposed on the site
and surrounding structures and land uses.
b. Include labeled entrances/exits.
c. Include a visual of each level with all parking spaces shown and ADA
spaces labeled.
d. Include a note that the 18-32.7.3 requirements are met: mechanical
equipment is screened/not visible; air handler emissions are away from
adjacent residential uses; and the structured parking is designed so that
light is not shining outside the structure.
e. Refer to Engineering comments as well.
13.18-32.7.2.3 Sidewalks and other pedestrian ways: Include safe pedestrian
access across the structured parking entrance. Refer to Engineering for more
detailed comments.
14.18-32.7.9.4(b) Landscape plan/preservation of existing trees: Include the
Conservation Checklist.
15.18-32.7.9.5 Street trees:
a. Show how the street tree requirement is being met. The frontage
calculation and how the requirement is being met for each street should
be included with the landscape plan. The requirement is:
One large street tree shall be required for every 50 feet of street
frontage, or portion thereof, if 25 feet or more. Where permitted,
one medium shade tree shall be required for every 40 feet of road
frontage, or portion thereof, if 20 feet or more.
b. The requirement does not appear to be met along the full length of
Inglewood Drive. Provide street trees meeting the above requirement
along Inglewood.
16. ZMA20010007 and ZMA20130009 Proffers:
a. Please note that the following proffers are directly applicable to this
project:
i. Proffer 6: $3,000 cash contribution per unit for each unit above 500
total units in Stonefield.
17.Additional applications: The following applications and approvals are required
prior to final site plan approval:
a. SUB201900150 is under review, pending a resubmittal to address
remaining review comments. Subdividing this parcel is not required for site
plan approval. However, if the parcel is subdivided and ownership
changes, this must be reflected on the site plan.
b. 18-32.7.4.2 and 18-32.7.5.3: Easement Plats: All new and adjusted
easements must be shown on an easement plat, which must be approved
prior to final site plan approval, and must match the final site plan.
c. Architectural Review Board: A Certificate of Appropriateness from the
ARB is required prior to final site plan approval.
d. 18-32.7.4.1: Approval of a VSMP Plan is required prior to final site plan
approval. See Engineering comments.
Engineering (John Anderson)
1. See review comments per attached letter dated November 19, 2019.
VDOT (Adam Moore)
1. No Objection. See attached letter dated November 21, 2019.
Fire/Rescue (Shawn Maddox)
1. The FDC must be shown on the plan and located within 100' of a hydrant. Based
on the height of this building the hose required to connect the FDC to the hydrant
shall not impact travel lanes.
2. A knox box is required. Please add a note indicating this requirement and that
the location can be coordinated with the fire marshal's office.
3. The travel way along one contiguous side of the structure must be 26' of
unobstructed travel way. There can be no utility lines, trees or other obstructions
along that side of the structure that would impede aerial fire apparatus access.
Based on the special exception requested for additional height this requirement
may change to more than one side.
4. Any overhang or covered entrance must have a clearance of 13'6".
5. Please provide the ISO needed fire flow AND a current fire flow test to show what
is available on site.
ACSA (Richard Nelson)
1. Submit 3 copies ATTN: Alex Morrison.
2. RWSA Capacity Certification will be required.
3. Contact Alex Morrison for draft connection fees
(amorrison(aD-serviceauthorit r�org).
RWSA (Dyon Vega)
1. RWSA Capacity Certification will be required.
Inspections (Michael Dellinger)
1. Sheet 1 does not address required accessible parking spaces, please provide.
2. Sheet 3: number 10, the state does not enforce the ADA rather the ICC ANSI
A117.1. Please refer to this code for accessibility requirements.
3. Sheet 8: drive thru canopy will require non-combustible construction due to the
proximity of the property line.
Architectural Review Board (Margaret Maliszewski)
1. This item is scheduled for the December 16 ARB meeting. Comments will be
provided at that time.
Zoning/Parking Reduction Request (Kevin McCollum)
1. Based on my analysis of the parking at Stonefield I cannot approve the
requested parking reduction associated with SDP2019-57 at this time. It appears
that the proposal of adding 234 apartment units to Block D1 would create a
parking shortage as this existing lot has been allocated as parking for two
already approved site plans, SDP2012-5 (the theater) and SDP2012-1 (the town
center). The Applicant needs to provide any additional information needed to
prove that this request would not create a shortage of parking that is required by
any of the applicable site plans. If any of the information I have is incorrect (since
our calculations for requirements and what is existing are different) they need to
provide evidence that their information is correct. I have used the approved site
plans that we have on file and I assume that those numbers are correct.
2. See attached documents entitled "Blocks and Parking Maps" and "Stonefield
Parking Analysis" for further details.
3. Parking reductions requested for other applications that have not submitted a site
plan (Block C2-1) cannot be processed without a site plan.
E911 (Brian Becker)
4. No Objection.