Loading...
HomeMy WebLinkAboutSDP201900064 Study Initial Site Plan 2018-12-17HIMPROJECT MANAGEMENT CIVIL ENGINEERING LAND PLANNING ENGINEERINGa December 17, 2018 Mr. Adam Moore, P.E. Virginia Department of Transportation 701 VDOT Way Charlottesville, VA 22911 Regarding: Proffit Road Townhomes Right and Left -Turn Warrant Analysis Mr. Moore, Please find enclosed a warrant analysis for the proposed Proffit Road Townhomes off of Proffit Road between Pritchett Lane and U.S. 29 Seminole Trail. Forty (40) townhomes are proposed with this development. The following items are included with this report: • VDOT Traffic Data • ITE Trip Generation Summary • Warrant Analysis Exhibit • OTISS Trip Generation Reports Our analysis shows that neither a left turn lane nor a right turn lane/taper is warranted for this project. If you have any questions you may contact me at jusX@s6imp-engineering.com or by phone at 434-953-6116. 3himr Engineering, P.C. The table below summarizes the 2017 VDOT traffic data for the 0.54 mile segment of Proffit Road between Pritchett Lane and U.S. 29 Seminole Trail, which was used to calculate the peak hour volume (PHV) approaching for the warrant analysis. Table 1. VDOT traffic data summary — Proffit Road AADT 7600 K factor 0.1135 D factor 0.5133 PHV (AADT*K*D) 443 Design Speed (mph) 35 Below is the ITE trip generation summary table that was used in combination with the direction factor of Proffit Road to determine the PHV right and left turns into the establishment. The OTISS graphs showing the source of this information are included as Figures 4 and 5. Table 2. ITE trip generation summary table AM PM Use Description ITE Qty in out Total in out Total Single Family Detached 210 40 Units 9 26 35 29 16 45 Right Turn 4 15 Left Turn 5 14 The higher number of right and left turns into the site was used in the right and left turn lane warrant analysis, shown in Figures 1 and 2 below. 2 F-79 IRD 100 0 x uU aCA 80 uu J C) S 60 3 F- C7 40 iz i PHV APPROACH TOTAL, VEHICLES PER HOUR Figure 1. Warrant for right turn treatment (2-lane highway) The figure above shows that neither a right turn lane nor taper is required for the site. The right turns were taken from Table 2, and the PHV approach total includes additional traffic that is to be generated by the site. 3 F-58 Warrants for Left Turn Storage Lanes on Two -Lane Highways Advancing volume and opposing volumes (VPH), speed and percent left turns are used to determine whether a left turn storage lane is warranted on two-lane highways_ The warrants in table below are taken from the 2011 AASHTO Green Book, Chapter 9, Section 9.7.3, Page 9-132, Table 9-23. They were derived from Highway Research Report No. 211, Figures 2 through 19, for required storage length determinations. WARRANTS FOR LEFT TURN LANES ON TWO-LANE HIGHWAYS VPH ADVANCINGVCLUME OPPOSING 5% 112% 20% 30% VOLUME LEFT TURNS LEFT TURNS LEFT RAUS LEFT TURNS 40-MPH DESIGN SPEED' 806 333 240 180 160 906 411) 305 225 200 40D 516 380 275 245 20D 94D 470 350 305 10D 72D 515 390 340 50-MPH DESIGN SPEED' 80D 281) 210 165 135 90D 351) 280 195 170 40D 43D 320 240 210 20D 553 4110 3U0 270 10C 5'F 445 335 205 B0-MPH DESIGN SPEED' 900 23D 170 125 115 806 291) 210 100 14(1 40D 365 270 200 175 20D 451) 330 250 215 100 505 370 275 240 TABLE 3-1 Source: Adapted from 2911 AASHTO Green Book, Chapter 9, Section 9.7.3, Page 9-132, Table 9-23 QPF W N9 MOIiJItE 1iPF♦} --------- — — — — K Wr(1re VXMMHI rlSFT.TJRN AUWE" Example: Two-lane highway with 40-MPH operating speed Opposing Volume (VPH) - 600 Advancing Volume (VPH) -440 Left -Turn Volume (VPH) - 44 or 10% of Advancing Volume With opposing volume (VPH) of -609 and 10% of advancing volume (VPH) making left toms, and advancing volume (VPH) of 305 or more will warrant a left -turn la ne. USE DESIGN SPEED IF AVAILABLE, when the Average Running Speed on IF NOT USE LEGAL SPEED LIMIT. an existing facility is available, the corresponding Design Speed may be obtained from Appendix A, Section A-1. Rev_ 7114 Figure 2. Warrant for left turn lane (2-lane highway) The highest amount of left turns into the site is estimated in the evening, with 14 left turns out of a total 434 vehicles advancing. The opposing volume at that time is approximately 458 cars. Since these data values did not quite match up with the data in Figure 2 above, a graph was created using the values in the 5% left turns category to interpolate a threshold for the opposing volume that would trigger a left turn lane. See Figure 3 below for the interpolation. 11 9 S 1 30 30 30 a� - CC 45$ CC NGTurn Lane 0 � 330 410 434 510 15-V 720 Advancing V011-ime (5; Left Turns) Figure 3. Interpolation of left turn warrant using data from Figure 2 The graph above shows that for 434 VPH advancing, with 5% left turns, the threshold that would trigger a left turn lane is about 550. Because 458 opposing VPH are expected, a left turn lane is not warranted. The following two figures display the source of the estimated trips generated by Proffit Road Townhomes. ®an ------- - --------- - ------- BATH SBORCE: ITE-TGM 10th Edition SEARCH BY LAND USE CODE: 210 LAND USE CATEGORY: (200-299) Residenlial LAND USE: 210 - Single -Family Detached Housing INDEPENDENT VARBIBLE (N): Dwelling lJnits TIME PERIOD: Weekday, AM Peak Hour of Generator SETTINGILOCATION: General HrhaNSuburban TRIPT M: Uhicle ENTER IVVALUETOCALC!.--ETRIPS: 4R cal••-ulale I Data Plot and Equation 150� 100i X 50: X X 0' ___d_________50 X Study Site Figure 4. OTISS trip generator A.M. peak hour X X jX X X X XX X XX XX X X�X X X X 11 X XX X X X X X X X x X XX xx XX X X J X XX X X X XX X X XX X X X X X 16V 150 200 250 %= Number of Dwelling Units Reset Zoom Restore — ritted Curve --- Average Rate DATA 511ATISTICS And use: X Single -Family Detached ld--g(210)Click for re detalls Independent Vanable: Dwelling Units Time Period: �Neekday Akt Peak Hour of General r Setting)Lacetian: General UlbanlSubulban Tnp TV": vehicle Number of Studies: 157 Avg. Num. of Dwelling Units'. 231 Average Rate'. 0.76 Range of Rates. 036-227 Standard Bevlation 0.25 Fluted Curve Equation: Lr(T)=091 Ln(X)-029 R2 089 Directional Distribution: 26%entering. 74% exiting Calculated Imp End.: 5 r Query Filter DATA SOURCE: ITE-TGM 101h Edition SEARCH BY LAND USE CODE: 210 O LA MD USE CATECART. (200-299) Residential LAND USE: 21D - Single -Family Detached Houeng INDEPENDENT VARIABLE p10: Dwelling Units TIME PERIOD: LVeekcii PM Peak Hgur o1 Generator lGeneral Ur-03.burban +I TRIP TYPE: /ehiele ENTER IV VALUE TO CALCULATE TRIP S: 40 Calculate Data Plot and Equation mil 100 Gil X = Number of Dwelling units Reset Zoom Restore X Study Site Fitted Curve Figure 5. OTISS trip generator P.M. peak hour DATA STATISTICS xXX Land Use: SinglrFalnlly Detached Housing (210) Click far ore defaiis Independent Variable: U Iling Unlrs X Time Period: Weekday PM Peak Hour of Generator Setting+Location: General lJ rM, Gubulban Trip Type: u hlcle Number of Studies: 165 Avg. Num. of Dwelling Units. 217 Average Rate 1 00 Range of Rates. Di 2.98 Standard Deviation'. oat Fitted Curve Equation: Ln(T) - C 94 Ln(X)+0 34 R� --- Average Rate 092 Dlmcdonal Disbibu Don', 64% entering. 36% exiting Calculated Tnp Entls'. no