Loading...
HomeMy WebLinkAboutSDP201800012 Action Letter 2019-10-21COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-45% Phone 434 2%-5832 Fax 434 972-4126 October 21, 2019 Andrew Allison 608 Preston Avenue Charlottesville, VA 22903 Andrew.Allison(a)timmons. com RE: LOR#3 for SDP2017-76 Woolen Mills Redevelopment Tax Map/Parcel Number 78-21 B Dear Mr. Allison This letter is to approve as a Letter of Revision the changes outlined in your letter of September 26, 2019 (attached) and shown on the submitted plans. This is the 3rd and final Letter of Revision for this site. A total of three (3) Letters of Revision are allowed before all changes to the plan are required to be submitted in the form of a site plan amendment. Sincerely, William . Fritz, AICP Development Manager/Ombudsman Attachments: Letter of Request Site Plan Change w TIMMONS GROUP YOUR VISION ACHIEVED THROUGH OURS. September 26, 2019 County of Albemarle Bill Fritz, AICP — Chief of Special Project Department of Community Development 401 McIntire Road Chadottesville, VA 22902 608 Preston Avenue P 434.295.5624 Suite 200 F 434.295.8317 Charlottesville, VA 22903 www dmmons.com RE: Woolen Mills Redevelopment — SDP-2017-76 Letter of Revision Dear Mr. Fritz: The following is a summary of changes reflected in the Letter of Revision #3 submission: Sheet C4.3: The sanitary sewer service location has been revised to stub out on the western side of the 1 story building. An additional sanitary sewer service connection has been provided for the 2-story brick building. The proposed private Fireline has been relocated from the drive aisle between the existing retaining wall and 1-story building. This line shall be installed beneath the restaurant space to avoid impacting the integrity of the existing wall. • Sheet C5.2: The proposed stormline has been relocated from the drive aisle between the existing retaining wall and 1-story building. This line shall be installed beneath the restaurant space to avoid impacting the integrity of the existing wall. • Sheet C7.2: Stormwater profiles have been revised to reflect the relocation of the storm line between the existing retaining wall and 1-story building. • Sheet C7.4: The waterline profile has been revised to reflect the relocation of the private fireline from the drive aisle located between the existing retaining wall and 1-story building. + Extent of pavement has been revised and two risers have been removed to match the latest landscape plans. - • Modifications to the E&SC plan was not required as part of this revision • Stormwater pipe routing calculations have been revised as part of this L.O.R. If you have any questions or comments, please feel free to give me a call at 434.327.1683. Sincerely, Andrew Allison Project Engineer CIVIL ENGINEERING i ENVIRONMENTAL I SURVEYING I GIs I LANDSCAPE ARCHITECTURE CONSTRUCTION SERVICES