HomeMy WebLinkAboutSDP201900065 Review Comments Initial Site Plan 2019-12-18COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 December 18, 2019 Justin Shimp, P.E. Shimp Engineering 912 E. High Street Charlottesville, VA 22902 justin(a)shimp-en in�g com RE: SDP201900065 Rio Road West — Initial Site Plan Dear Mr. Shimp: The Site Review Committee has reviewed the development proposal referenced above. Initial comments from the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Planning Services (Planner) Albemarle County Engineering Services (Engineer) (attached) Albemarle County Architectural Review Board (ARB) (attached) Albemarle County Information Services (E911) Albemarle County Building Inspections (attached) Albemarle County Department of Fire Rescue (attached) Albemarle County Service Authority Virginia Department of Transportation Rivanna Water and Sewer Authority (attached) Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that will be required to be resolved prior approval of the major site plan amendment. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, Lt, ' " Cameron Langille Senior Planner Albemarle County Planning Services (Planner) — Cameron Langille, blan ilg_lekalbemarle.org — Required changes: Comments to be addressed urior to initial site elan aunroval: 1. [32.4.2.3 and 32.4.2.41 See ARB comments #1-3. Based on ARB comments, the initial site plan cannot be approved until a resubmittal is provided that addresses the ARB comments. The initial site plan will need to be deferred so that the applicant can revise the drawings as necessary and staff can review and verify that those comments are addressed. A deferral request must be sent to Planning staff no later than Friday, January 3, 2020. Otherwise, the initial site plan will be denied in accordance with Section 32.4.2.5. 2. [32.4.2.1 (f)] Please submit payment for the required SRC meeting notification fee. Fee is $435.00 and must be paid prior to approval of initial site plan. Payment must be received by Albemarle County prior to Friday, January 3, 2020. 3. [32.4.2.3 and 32.5.2 (n)] See Fire & Rescue comment #1. The site layout needs to be revised so that an unobstructed 26' wide aerial fire apparatus lane is located along one side of the mini -storage building. Until Fire Rescue staff advise Planning staff that this comment has been addressed, the initial site plan will not be approved until the layout is modified. 4. [ZMA201800013 and 32.5.2 (i)] As stated in Proffer #1 and shown on Sheet 4 of the Application Plan of ZMA201800013, the owner is required to draft and record an access easement to allow for interparcel connectivity and shared access to Rio Road for adjacent parcels. The site plan shows a possible interconnection with TMP 45-102 to the east, but no interparcel connections are shown to the west with TMP 45-100B. The access easement is intended to allow for a future local street ("Type C" local street cross-section as shown in the Rio29 Small Area Plan). Please explain how this proffer will be met; there does not appear to be a suitable area on site to establish the interparcel connection to the west due to the proposed sidewalks and retaining walls along the western property boundary. The site layout may need to be revised so that a western interparcel connection can be provided or be possible in the future. [4.16] The site plan does not identify any recreational amenities as required by Section 4.16 of the Zoning Ordinance. Recreational amenities shall be provided for every development of 30 units or more equal to or exceeding four dwelling units per acre. Staff has concerns about there being adequate area within the development to provide some of the required facilities as listed below. a. [4.16.2.1] A minimum of 200 square feet of recreational area must be provided per dwelling unit proposed, but this requirement shall not exceed 5% of the gross site area. Provide a calculation that identifies how many square feet of recreational areas are required. b. [4.16.2.1] The minimum facilities include one tot lot for the first 30 units, plus an additional tot lot per each additional 50 unit increments. Tot lots must include the following: i. One swing (four seats); ii. One slide; iii. Two climbers; iv. One buckabout or whirl; v. Two benches. c. [4.16.2.1] Each tot lot shall consist of at least 2,000 square feet and shall be fenced, where determined necessary by the director of planning and community development, to provide a safe environment for young children. d. [4.16.2.2] One-half court for basketball shall be provided for each 100 units, consisting of a 30- foot by 30-foot area of four -inch 21-A base and 1% inches bituminous concrete surface, and a basketball backboard and net installed at regulation height. e. [4.16.2.1] Please be aware that substitutions of equipment or facilities may be approved by the director of planning and community development, provided they offer a recreational amenity equivalent to the facilities listed above, and are appropriate to the needs of the occupants. If the applicant requests a substitution to these facilities and equipment, please provide a written narrative of the request and explain what recreational amenities will be substituted for the Zoning Ordinance requirements. If a substitution request is submitted and approved, the plan will need to show the proposed recreational amenities and state square footage, equipment, etc. Cut -sheets will be needed for any playground equipment proposed. Comments to be addressed prior to final site plan approval: 6. [ZMA201800013] Please provide a block plan that identifies boundaries of Blocks 1-3 within the development, as specified on Sheets 3 and 9 of the Application Plan. The final site plan must demonstrate that each block meets the minimum acreages, block depths, and lot & building requirements (additional information shown on page 6 of the Code of Development). 7. [ZMA201800013 and 8.5.5.1 (b)] Please provide a phasing plan that identifies/explains when improvements will be provided in each block, as specified in Section X of the Code of Development and Proffers #2, #3, and #5. 8. [ZMA201800013 and 32.5.2 (o)] Per Proffer #3, the multi -use path in Block 3 shall be dedicated to the County for public access and maintenance prior to the development of any portions of the trail located directly adjacent to the property. Concurrent with the dedication of the multi -use path, the owner shall dedicate a portion of the property inclusive of the stream and north of the stream, approximately 0.4 acres, to the County to be incorporated into a linear park network as shown in the Rio 29 Small Area Plan (dated December 12, 2018). Although the dedication of the multi -use path and 0.4 acre park area do not need to occur prior to final site plan approval, please provide an explanation on whether the owner will dedicate these features prior to final site plan approval or at a later date. 9. [32.5.2 (a) and ZMA2018000131 Per Proffer #5A, the owner must dedicate eleven (11) feet of the property along Rio Road W, as shown on Sheet 7 of the applicant plan, to public right-of-way. The subdivision application for the right-of-way dedication must be approved and recorded prior to final site plan approval. a. References to the instrument (deed book and page number) that recorded the right-of-way dedication will need to be added to the final site plan. 10. [32.5.2 (a)] Albemarle County GIS shows that portions of the site lie within the Managed Steep Slopes Overlay District. Please add this overlay district to the Zoning Note on Sheet C 1. 11. [32.5.2 (a)] Please revise the Zoning Note on Sheet C1. ZMA201800013 was approved on August 21, 2019. 12. [ZMA201800013 and 32.5.2 (a)] Due to the amount of lot and building regulations that apply to this site per the Code of Development, please remove the setback and building heights notes on Sheet C1, and insert Table D (including footnotes) from Section IX of the COD to Sheet Cl. This will ensure that all applicable lot and building regulations are verified and complied with at time of building permit review and approval. a. Please provide a note stating the percentage of lot coverage in all three blocks. See note 6 under Table D for the definition of lot coverage. b. [32.5.2 (n)] Please provide information on the height of proposed buildings in both stories and feet. If stepbacks are required based on building heights, consult Table D and add notes clearly explaining where steobacks apply to the proposed buildings. 13. [32.5.2 (a)] Please remove the proffer notes currently shown on Sheet C 1. Add the entire proffer statement (including owner signature page) as an exhibit to the final site plan. 14. [32.5.2 (b) and ZMA2018000131 Please add Table B (including footnotes) from Section IV of the Code of Development as an exhibit to the site plan. a. Add lines to the note stating the acreage/size, number of dwelling units, gross density, and amount of non-residential square footage proposed in each block. 15. [ZMA201800013 and 8.5.5.1 (b)] Please provide an exhibit/fagade rendering for the proposed Building in Block 2 on the final site plan. The exhibit must demonstrate compliance with the Architectural Standards specified in Section VII of the COD. a. Include the Additional Architectural Standards table (including footnotes) from Section VII to the exhibit. Provide evidence that facades of the Block 2 building meet all applicable standards. 16. [32.5.2 0)] Please label all existing water, sewer and drainage easements by type and include a size/width measurement. State the deed book and page for the recorded instrument number in each easement label. 17. [32.5.2 (k)] Any new easements required for water, sewer, and drainage facilities will need to be reviewed, approved, and recorded prior to final site plan approval. Please submit an easement plat application the County for review. The final site plan will need to be updated so that all easements are shown and labeled identifying easement type, whether it's public or private, a width dimension, and the recorded instrument with deed book and page number. 18. [ZMA201800013 and 32.5.2 (b)] Please provide a table or note explaining the types of greenspace and amenities that will be provided in each block in accordance with Table C from Section V of the Code of Development. a. Clearly identify and label these features on the site layout drawings. 19. [32.5.2 (n) and 4.12.61 Parking verification. a. Please provide a calculation identifying what mix of uses are proposed in Block 1. The Parking Schedule on Sheet C1 implies that dwellings will be provided in the Block 1 building, but the plans do not state how many units per bedroom count. Provide this information so staff can verify that adequate parking is provided. b. Please provide a calculation of parking required for other uses (such as retail) that will be provided in Block 1. The Zoning Ordinance has specific calculations for different commercial and retail uses which could potentially occupy the building. Additional information of specific uses proposed is necessary to verify adequate parking is being provided. Additional spaces may be needed pending response to this comment. c. Clearly state how many employees will be working in Block 2. The Parking Schedule only states the standard and does not provide a calculation of the minimum required. 20. [32.5.2 (n) and 4.12.13(c)] No loading spaces are identified on the site plan. The Zoning Ordinance requires that loading spaces be provided based on the following square footage of proposed uses: (1) one space for the first 8,000 square feet of retail gross leasable area, plus one space for each additional 20,000 square feet of retail gross leasable area; (2) one space for the first 8,000 square feet of office space plus one space for each additional 20,000 square feet of office space; or (3) one space for the first 10,000 square feet of industrial floor area plus one space for each additional 20,000 square feet of industrial floor area. a. Please provide a square footage calculation of the retail gross leasable area and office space in Block 1 to determine how many loading spaces are required for Block 1. b. Based on the proposed 100,000 sq. ft. of the self -storage in Block 2, six (6) loading spaces complying with the design standards of 4.12.18 are required on -site. c. Please be aware that the applicant may request a modification or waiver from the Zoning Administrator to providing the minimum amount of required loading spaces in accordance with Section 4.12.13. A Special Exception application must be filed if the applicant wants to request a reduction to the loading space requirements, which includes a fee of $457.00. 21. [32.5.2 (a)] Please provide a breakdown of the types and quantities of dwelling units that will be provided. a. Identify the proposed density of the development. 22. [32.5.2 (n)] ADA compliant striping/accessible aisles must be provided within the site where handicap accessible parking spaces are provided on opposite sides of travelways from building entrances. Please provide striping from the handicap space at the rear of the site to the entrance of the building in Block 2. a. See Inspections Division comments for additional requirements on the minimum number of handicap spaces provided, as well as ADA signage. 23. 132.5.2 (n)] Profile view details of all proposed fences, retaining walls, and constructed screening measures will be required with the final site plan. Each will need to show the types of materials used and dimensions. a. See Engineering Division and Inspections Division comments for additional details on retaining wall requirements. 24. [32.5.2 (n)] Per sheet 9 of the Application Plan, how will pedestrians cross the proposed travelway to connect to the sidewalk along the western property boundary that leads down to Block 3? No ADA compliant ramps are shown at sidewalk termination points, and no pavement striping is shown within the site. 25. [32.5.2 (n), 4.12.19, and 32.7.9.71 Please identify what screening measures will be provided for the proposed dumpster pad area. If a constructed screen will be provided, include a plan and profile view of the enclosure identifying materials, dimensions, etc. 26. [32.7.91 Please update the plant schedule so that the botanical name, common name, and quantity columns are filled out. These columns are currently blank or state "TBD." 27. [32.7.9.61 Once the canopy provided within the parking lot has been identified, update the square footage of the total canopy provided in the note on Sheet C6. 28. [32.7.9.813,700 sq. ft. of existing canopy will remain and count toward the total site canopy required (as currently stated on Sheet C6) the owner will need to sign the Conservation Plan Checklist and this will need to be added as an exhibit to the Landscape Plan. a. [32.7.9.4 (b)] Verify the locations, species, and sizes of all existing vegetation that will remain and count toward the canopy. Several trees are currently identified on Sheet C6, but these do not appear to make up 3,700 sq. ft. of canopy. Verify/provide evidence that the canopy does total 3,700 sq. ft. if these are the only items that will remain. 29. [32.7.9.81 The site plan does not currently state the proposed residential density. The landscape plan states that the overall canopy required is 10%. This is true for Block 2 since it is only commercial/industrial use. However, the canopy percentage required within Block 1 may be different depending on the proposed density, and the landscape plan may need to be revised. The canopy requirements based on density are as follows: a. [32.7.9.8 (a)] Gross density of 20 units/acre or more = 10% canopy; b. [32.7.9.8 (a)] Gross density between 10 and 20 units/acre = 15% canopy; c. [32.7.9.8 (a)] Gross density of 10 units/acre or less = 20% canopy. 30. [32.7.9.9 and ZMA2018000131 Please add a note to Sheet C6 stating "Landscape improvements in Block 1 shall be provided in accordance with the proffer statement provided with ZMA201800013. Block 1 shall be a maintained landscape until the Block is improved with structures." 31. [32.7.8 and 4.171 A lighting plan will need to be included with the final site plan submission that complies with all applicable regulations specified in Section 4.17 of the Zoning Ordinance. This includes: a. Provide footcandle measurements within the property and along all property lines. Use a light loss factor of 1.0 to determine footcandles on site. b. [4.17.4 (a)] Provide manufacturer cut -sheets for all proposed outdoor luminaires. c. [4.17.4 (a)] All proposed outdoor luminaries exceeding 3,000 lumens must be full -cutoff fixtures. Please provide documentation from the manufacturers that all fixtures will be full -cutoff. d. Please state the pole height of all outdoor luminaires. e. [4.17.4 (b)] Add a note stating "The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half (1/2) foot candle." f. Please add a note to which states "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half footcandle." Please contact Cameron Langille at the Department of Community Development at blan ig llekalbemarle.org or 296- 5832 ext. 3432 for further information. Comments From Other Reviewers: Albemarle County Engineering Services (Engineer) — Emily Cox, ecox2&a1bemarle.org — Requested changes, see attached. Albemarle County Architectural Review Board (ARB) — Paty Saternye, Psaternye@albemarle.org — Requested changes, see attached. Albemarle County Information Services (E911) Andy Slack, aslackkalbemarle.org, No objection. Albemarle County Building Inspections — Michael Dellinger, mdellingerkalbemarle.org — Requested changes, see attached. Albemarle County Department of Fire Rescue — Shawn Maddox, smaddoxgalbemarle.org — Requested changes, see attached. Albemarle County Service Authority — Richard Nelson, melson(&serviceauthority.org — ACSA review not yet complete, comments or recommendations will be forwarded to the applicant upon receipt. Virginia Department of Transportation — Willis Bedsaul, willis.bedsaul(&vdot.vir ig nia.gov — VDOT review not yet complete, comments or recommendations will be forwarded to the applicant upon receipt. Rivanna Water and Sewer Authority — Victoria Fort and Dyon Vega, vfortgrivanna.org and dvegakrinavvan.org — Requested changes, see attached. Cameron Langille From: Emily Cox Sent: Monday, December 9, 2019 12:43 PM To: Cameron Langille Subject: Planning Application Review for SDP201900065 RIO ROAD WEST - INITIAL - DIGITAL. WPO plan must be approved before final site plan can be approved. -Provide a detail for the proposed multi -use path. -Retaining walls will need engineered design and building permits. -Ensure all proffers are met (25% treatment on site and others). The Review for the following application has been completed: Application Number = SDP201900065 Reviewer = Emily Cox Review Status = Requested Changes Completed Date = 12/09/2019 This email was sent from County View Production. COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 December 17, 2019 Justin Shimp Shimp Engineering 912 East High Street Charlottesville, VA 22902 RE: ARB-2019-129: Rio Road West (TMP 04500-00-00-10000, 04500-00-00-100AO, 04500- 00-00-10100 & 04500-00-00-101 BO) Dear Mr. Shimp, At its meeting on Monday, December 16, 2019, the Albemarle County Architectural Review Board unanimously voted to forward the following recommendations on the above -noted Initial Site Development Plan to the agent for the Site Review Committee: The ARB does not recommend approval of the initial site plan at this time. Prior to Initial Plan approval the following items must be resolved to the satisfaction of the ARB: 1. Revise the plan to include a landscape plan that will be implemented in the general area of the Building 1 footprint to help mitigate the appearance of the self -storage building and the parking lot prior to Building 1 construction. 2. Revise the retaining wall design to incorporate terracing and planting for those visible walls (from the EC) over 6' tall. 3. Provide site sections and correct FFEs. Regarding the final site plan submittal: A Certificate of Appropriateness is required prior to final site plan approval. In addition to the required items listed in the Final Site Plan checklist, the following items must be addressed: 1. Include details for the dumpster enclosure and loading zone gates in the site plan. Identify screen type, material, manufacturer and color. 2. Show how visibility of all mechanical equipment will be eliminated from the EC. 3. Revise the plan to provide the required large shade trees along the EC, at the required spacing and caliper. Revise the spacing and quantity of ornamental trees accordingly. 4. Revise the landscape schedule to identify all plant species and to reflect accurate quantities. 5. Revise the plan to show that there are no conflicts between the utilities and the proposed landscaping. 6. Provide large shade trees, 2'/" caliper at planting, spaced 40 feet on center, along the accessways. 7. Provide medium shade trees, at least 21/" caliper planting, spaced 25 feet on center, along pedestrian ways. Show trees in a naturalistic planting pattern along the multi- use path 8. Provide large trees along the perimeter of the parking area spaced 40' on center at 2'/2" caliper. Identify species whose mature size will not encroach in the accessways and parking spaces. 9. Provide an additional large tree within the interior of the parking area. 10. Provide shrubs, 24" at planting, in the perimeter planting areas on the east and west sides of the parking lot. 11. Revise the proposed contours such that they appear natural, rounded and do not have less than a ten -foot radius throughout the site where they blend with the existing topography. 12. Revise the utility layout to avoid conflicts with required improvements. You may submit your application for continued ARB review at your earliest convenience. Application forms, checklists and schedules are available on-line at www.albemarle.org/ARB. Please be certain that your ARB submittal addresses the above -noted issues. If you have any questions concerning any of the above, please feel free to contact me. Sincerely�� rJ Paty stern Senior Planner cc: Auto LLC 1389 Richmond Road Charlottesville, VA 22901 File Review Comments for SDP201900065 Initial Site Plan Project Name: RID ROAD WEST - INITIAL - DIGITAL DateCompleted: Friday, November 08, 2019 Department/Division/Agency: Review St, Reviewer: Andrew Slack No objection_ DD E911 No Objecti Review Comments for SDP201900065 Initial Site Plan Project Name: RI ROAD WEST - INITIAL - DIGITAL Date Completed: Thursday, November 07. 2019 DepartmentlDivisionlAgency: Review Status: Reviewer: Michael Dellinger CDD Inspections Requested Changes Using most restrictive table, 5 HO spaces need to be provided_ Table 1106.1( ) VOO_ Add the follo}r5,ing note to the general notes page: Accessible parking spaces and access isles shall not have a surface slope greater than 148 Access isles shall be at the same level as the parking space they serve_ Please provide critsheet for accessible parking }r5,ith signage requirements Add the follo}r5,ing to the general notes page: All roof drains shall discharge in a manner not to carise a public nriisance and not over side,,valks Page: County of Albemarle Printed On: 12 18120'19 Review Comments for SDP201900065 11nitial Site Plan Project Name: RI ROAD WEST - INITIAL - DIGITAL Date Completed: Wednesday, December 18, 201 DepartmentlaivisionlAgency: Review Sys: Reviewer: Shawn Maddox Fire Rescue Reueste changes 1 _ Due to the size, and height, of the building an aerial fire apparatus lane of 6' unobstructed width must be provided no closer than 16' and no farther than 30' from the structure along one contiguous side_ The mini storage building does not meet this requirement- _ A knox box will be required for each building, please add a note indicating this requirement- 3- Based on current parking and access there is not access within 150 feet (45 T20 mm) of all portions of the facility and all portions of the exterior walls of the first story of the building as measured by an approved route arorind the exterior of the building or facility- 4- 1 do not see any fire hydrants located on site_ If these buildings are to be sprinklered you must show the FDD and have a hydrant within 100' of the connection_ Hydrants should be provided on site to meet the 500' spacing requirement_ These should be arranged to ensure that during their use traffic flow is not impacted. 5_ The travel way serving as the aerial fire apparatus access along each building shall be marked no parking fire lane 6_ Provide the ISO needed fire flow for each structure and provide the current fire flow available on site_ Page: County of Albemarle Printed On: 12 18120'19 Cameron Langille From: Dyon Vega <DVega@rivanna.org> Sent: Wednesday, November 27, 2019 8:03 AM To: Cameron Langille Cc: vfort@rivanna.org; Richard Nelson Subject: SDP201900065 Rio Road West Initial site plan comments CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. Cameron, RWSA has reviewed the Rio Road West initial site plans and has the following comments: General comments: RWSA will require a sewer flow acceptance prior to final site plan approval. The request will need to be sent to us by ACSA and will include the following: • Estimated average daily dry weather sewage flow (ADDWF) • Point of connection into RWSA system (which manhole) • Number of units/square footage • Estimated in-service date Let me know if you have any questions. Dyon Vega Civil Engineer WATER& SEWERAUTH0RITY Rivanna Water & Sewer Authority (434) 977-2970, Ext. 170 695 Moores Creek Lane Charlottesville, VA 22902 www.rivanna.org Cameron Langille From: Victoria Fort <vfort@rivanna.org> Sent: Thursday, November 7, 2019 4:48 PM To: Cameron Langille Cc: Dyon Vega; Richard Nelson Subject: SDP201900065 Rio Road West - Initial Site plan CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. Cameron, RWSA has reviewed the initial site plan for Rio Road West and has the following comment: 1. A sewer flow capacity certification will be required prior to final site plan approval if the proposed development is anticipated to produce over 40,000 gallons of sewage per day. Thank you, Victoria Victoria Fort, P.E. Senior Civil Engineer Rivanna Water and Sewer Authority 695 Moores Creek Lane Charlottesville, VA 22902 (0): (434) 977-2970 ext. 205 (F): (434) 295-1146